Loading...
38A-139 25. Fireplaces require all combustion air be provided from the exterior and below the firebox, duct work maintaining 1" clearance for 5'from the duct outlet for all fireplaces 26. Fire and draft stopping shall be completed before rough inspection. 780 CMR R302. 27. Ignition barriers in place before final. 780 CMR R316. 28. Dwelling/Garage fire separation. An attached garage (within 3' of main structure) is required to have%" drywall on the garage side of the separation wall and if there is a finished space above the garage all walls must have%2" drywall and the ceiling 5/8" drywall. 780 CMR R302.6 29. Energy aspects shall comply with the stretch energy code. 780 CMR Appendix 115AA or 2009 IECC. a. An initial HERS evaluation is required including insulation levels anticipated. b. A final HERS evaluation confirming code requirements have been met including duct testing. c. Energy information including mechanical equipment posted on the electric panel. d. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy Star Building Option Package. 30. Vapor retarders. Although these are still in the code have exceptions, one must understand that there is a difference between a vapor retarder or barrier and an air barrier. An air barrier is intended to stop air flow (convection) a vapor retarder or barrier is intended to stop molecular moisture transfer(diffusion). A vapor retarder or barrier is effective even if there are some holes or gaps, however an air barrier has to be absolute and complete. If air can leak through an electrical device or through a crack it follows the path of least resistance and carries 99%of the moisture in a structure.This is evident every time one exposes fiberglass insulation and finds black insulation, which is dirt filter out of the air moving through the insulation. 780 CMR R601.2 for vapor retarders and Table N1102.4.2 for air sealing requirements. 31. Unvented attic assemblies. Hot roofs are allowed, but have specific requirements 780 CMR R806.4. 32. Deck ledgers and post must be appropriately attached, bolts or lags. 780 CMR R502.2.2.1 Note:Thrul_oks are engineered for post attachment supporting a railing. 33. Smoke and CO detectors as required. 780 CMR R314 and R315. 34. Closets beneath stair which have doors must be drywalled with%2". 780 CMR R302.7 Relevant items must be submitted to the building department for approvals before inspections and or CO can be signed. Other items are intended to avoid costly issues at inspections. Feel free to call if you have any questions. My telephone number is 587-1240 and office hours are Monday through Friday, 8:30 am to 4:30 pm, excepting we close for walk-ins at 12:00 noon on Wednesdays. My email address is: cmiller(EDnorthamptonma.gov Thank you for yo, cooperation on these matters. Chuck Miller City of Northampton Assistant Commissioner and Zoning Enforcement 10. Steel straps over the ridge or 1x4 minimum collar ties are required 4' OC in the upper 1/3rd 780 CMR R802.3.1 11. Ridge boards must be the full depth of the cut. 780 CMR R802.3. 12. A complete window and header schedule is required. 780 CMR Table R502.5 for header sizing and number of jack studs required. 13. All framing materials which are not code prescriptive must have stamped engineering. a. LVLs b. I-joist and or Floor Truss c. Roof truss 14. A braced wall plan identifying appropriate braced wall areas and braced wall method being used.780 CMR 602.10. a. Garage corners and large corner window/door layout may require special solutions. b. All corners must be appropriately attached to the foundation. 15. Ceiling heights minimum 7'for habitable spaces, 6'8" for bathrooms includes tub/shower area if a shower head is used, 6'8" for basements, 6'4" at beams/ducts. 780 CMR R305.1. MA amended 16. Hazardous glazing locations, within 24" of a door, or within 60" of a stair, or across from hot tubs,spas, bathtubs within 60" if not 60" above the walking surface, and other locations. 780 CMR R308.4 17. Windows over 72" above grade with the opening less than 24 above the finished floor shall meet the 4" sphere rule. Order restrictors. 780 CMR R612.2 18. Egress and emergency escape requirements shall be strictly met. a. Basements, habitable attics, and all sleeping rooms require emergency escape.780 CMR R310 b. Windows within 44" of floor, DH 3.3 sqft min window size, Casement 20x41" exception 5 sqft at 1St floor. Minimum clear opening 20"x24" or 24"x20". 780 CMR R310.1.1 c. Two doors remote as possible at the normal level of travel, opening measured from the face of the slab to the stop with door at 90 degrees, one 32" and one 28" minimum 78" high. 780 CMR R311.2 d. Landing at each door 36" out and the width of the door minimum 36", maximum step 7 YV from the top of the threshold and only in-swinging doors. 780 CMR R311.3 19. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9", maximum riser 8%", maximum overall variance for the run is 3/8",4" sphere rule on risers except where the total rise is 30" or less 780 CMR R311.7.4.3 Exception,4 3/8" on balustrade, 6" in the triangle. Graspable rail 1%" minimum and 2" maximum rail, height minimum 34" maximum 38", required for 4 or more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling height from nosing. 780 CMR R311.7. 20. Guards 36" minimum height above walking surface, a bench is a walking surface, required for more than 30" above floor or grade within 36",4" sphere rule.780 CMR R312.1. 21. Educate the plumber and electrician about maximum notch and hole sizes, and placement.780 CMR R502.8 and R602.6. In bearing studs holes not larger than 40%of a stud no closer than 5/8 to the edge, In interior non-bearing studs holes not larger than 60%of a stud no closer than 5/8 to the edge, in bearing walls if more than 50%of a plate is cut or notched a 1%2" 16ga. strap must extend a minimum of 6" past the cut both directions and be nailed with 8-10d per side,or holes in joist are a maximum 1/3 the depth not closer than 2"from the top or bottom. Notches are different. 22. Dryer duct transition is limited to 8' of aluminum flex and must be exposed. 780 CMR M1502.4.3 23. Dryer duct maximum equivalent length is 25' or per manufacturer's specs. 780 CMR M1502.4.4.1, no screwed connections. 24. Markup air is required for any exhaust hood of 400 CFM or more.780 CMR M1503.4 City of Northampton f--' Massachusetts Y %. tv "E ti DEPARTMENT OF BUILDING INSPECTIONS , 212 Main Street • Municipal Building Northampton, MA 01060 INSPECTOR Kent Pecoy&Sons Construction December 26, 2014 215 Baldwin Street West Springfield, MA 01089 Subject Location: 115 Moser Street Lot# 15 Map Block: 31C-033 Mr. Pecoy, Please follow up on the following items: 1. The two windows at the bottom of the stairs are in a hazardous location, which requires them to be tempered if within 60" of the floor. The window next to the closet is considered a hazardous location and requires tempered glazing. 2. Electronic copies of stamped structural drawings are required for all none code prescriptive framing. Some examples are 1-joist, LVLs, floor or roof truss. 3. Rafters set on plates require positive attachment to the joist/deck with straps having a minimum of withdrawal strength of 450 lbs. 4. An air barrier is required on the inside of the 2nd floor band insulation. 5. All post supporting structure must have positive connection for wind uplift protection using fasteners or straps appropriately sized. 6. The garage must have ceiling or rafter ties to prevent spread or a structural ridge must be used. As of August 4th 2011 the 8th Edition MA code is the 2009 IRC with MA amendments. In the following are some generic requirements which seem to be problematic. This is not a substitute for purchasing and reading the MA codes. Note:The 2012 IECC with MA amendments is the non-stretch energy code and the new Stretch Code expected to be completed in February 2015. 1. Structures shall conform to 780 CMR 8th Edition 1 and 2 family building codes with MA amendments. 2. Grading plan for structures being constructed required. 780 CMR R401.3 for drainage requirements. 3. A basement drainage system is required in all basements 780 CMR R405.2.3.except those in group I soils (table R405.1) 4. Foundations that retain earth and enclose interior space require damp proofing 780 CMR R406.1. 5. Through wall form ties must be removed from both faces and patched with hydraulic cement. 780 CMR R406.2 of amendments. 6. Foundation anchor bolts must be%" and be embedded a minimum of 7" into the concrete. 10" bolts! 780 CMR R403.1.6 7. Foundation walls require horizontal reinforcement 2#4 bars one within 12" of the top and one in the middle if 8'or less and 3#4 bars at top and 3rds if over 8'. 780 CMR R404.1.2(1).Also see vertical reinforcement requirements. 8. CMU foundations require 3/8" parging before damp proofing. 780 CMR R406.1 see exceptions. 9. Ceiling joist are intended to prevent spread,once raised above the wall plate they become rafters ties and may require up sizing of rafters and increased nailing for example with a 4" slope 8-16nd common are required at each connection. 780 CMR R802.3.1. When there is neither of these a structural ridge is required with a load path to the foundation. City of Northampton Mail - Building permits lots AS-7&A-15 https://mail.g000,e.com/mail/u/0/?ui=2&ik=39211afc3d&view=pt&q... Charles Miller<cmiller @northamptonma.gov> Building permits lots AS-7 & A-15 1 message Don Clarke <DClarke @pecoy.com> Tue, Dec 16, 2014 at 9:13 AM To: "cmiller @northamptonma.god' <cmiller @northamptonma.gov> Good Morning Chuck, These are the next two we will be starting on. I will bring in the paper work this week. A-15 model has been built on lot A-19, 123 Moser. � ft A-7 model has been built on lot A-5, 95 Moser. We only added a small bump out to accommodate a shower on the irst floor. Thanks, Don Clarke, Senior Project Manager The Pecoy Companies DESIGN I BUILD I REMODEL I MAINTAIN 215 Baldwin Street West Springfield,MA 01089 Direct Line:413-304-3879 Office:413-781-7008,Ext.3879 Fax:413-781-7150 Email:dclarke @pecoy.com 2 attachments 1 of 2 12/18/2014 2:45 PM Registry ID: Rating Number: HERS-405 Certified Energy Rater: MattTurcotte Rating Date: 12/16/14 99 Moser St Rating Ordered For: Northampton,MAO 1060 Estimated Annual Energy Cost Projected Rating Use MMBtu cost Percent 5 Stars Plus Projected Rating: Based on Plans, Field Confirmation Required Heating 28.8 $ $76 28%5% Uniform Energy Rating System Energy Efficient Cooling 1.5 $76 Hot Water 11.0 $155 10% 1 Star 1 Star Plus 2 Stars 12 Stars Plus 3 Stars 3 Stars Plus 4 Stars 1 4 Stars Plus 1 5 Stars 5 Stars Pius Lights/Appliances 18.6 $843 56% 500-401 1 400-301 300-251 7 250 201 200 151 150 101 100 91 90-86 85-71 70 or Less Photovoltaics -0.0 $-0 -0% HERS Index: 54 Service Charges $0 0% General Information Total 59.9 $1492 100% Conditioned Area: 1345 sq.ft. HouseType: Single-family detached Conditioned Volume: 16353 cubic ft. Foundation: Conditioned basement This home meets or exceeds the minimum Bedrooms: 2 criteria for all of the following: Mechanical Systems features Heating: Fuel-fired air distribution,Natural gas,97.0 AFUE. Cooling: Air conditioner,Electric,16.0 SEER. Water Heating: Instant water heater,Natural gas,0.95 EF,0.0 Gal. Duct Leakage to Outside: 14.00 CFM25. Ventilation System: Balanced:ERV,36 cfm,24.0 watts. Programmable Thermostat: Heating:Yes Cooling:Yes Building Shell Features Ceiling Flat: R-59.2 Slab: R-0.0 Edge,R-0.0 Under Sealed Attic: NA Exposed Floor: NA Vaulted Ceiling: NA Window Type: U-Value:0.300,SHGC:0.250 Above Grade Walls: R-26.0 Infiltration Rate: Htg:2.50 Cig:2.50 ACH50 Foundation Walls: R-10.1 Method: Blower door test Lights and Appsance Festmes TITLE Percent Interior Lighting: 80.00 Range/Oven Fuel: Natural gas Company Percent Garage Lighting: 80.00 Clothes Dryer Fuel: Electric Address Refrigerator(kWh/yr): 0.00 Clothes Dryer EF: 3.01 City,State,Zip Dishwasher Energy Factor: 0.00 Ceiling Fan(cfm/Watt): 0.00 Phone# The Home Energy Rating Standard Disclosure for this home is available from the rating provider. Fax# REM/Rate-Residential Energy Analysis and Rating Software v14.5.1 This information does not constitute any warranty of energy cost or savings. ©1985-2014 Architectural Energy Corporation,Boulder,Colorado. MUNICIPAL WATER AVAILABILITY APPLICATION Northampton Water Department 237 Prospect St. Northampton,MA 01060 587-1097 A Department of Public Works Trench Permit shall be required prior to any construction or connection activity associated with this application. Location: 99 Moser Street, Lot A7 Inquiry Made By: Don Clarke, Kent Pecoy& Sons 246-3749 Date of Inquiry: 11/24/14 Number of Type of Single Family X Type of Private X Units: 1 Units : Ownership:� ) Apart. Comm. P: Condo Multi-family Rental (Annlicant to fill nut the above) Municipal Water Main in Existing service to Front of Location? Yes: X No: site? Yes: X No Size of Water Main: 8" Material: Ductile Iron Age: 2011 Approximate Static Street Flow Test Conducted: Yes: No: X Pressure: 110psi If done attach results Size of Service Connection Suggested Meter Size: 5/8" Comments: The Water Department cannot guarantee adequate water pressure during peak demand times at elevations above 320 feet. • A corresponding water entrance fee shall be paid prior to making any connection to the municipal water system. • Arrangements of such installation shall be made with the Northampton Water Department with a minimum of 5 working days notification. • 11 work shall conform to Northampton Water Department specifications. re .Nuttelman, Superintendent of Water Dept. Water Entry$ 200 Meter$ 100 Radio $ 100 cc: Ned Huntley, Director Note: If this availabilitv is for a new construction,it must be hand delivered to the Building Inspector. MUNICIPAL SEWER/AVAILABILITY APPLICATION Northampton Streets Department 125 Locust Street Northampton, MA 01060 587-1570 A Department of Public Works Trench Permit and Sewer Entry Permit shall be required prior to any construction or connection activity associated with this application. Location: 99 Moser Street, Lot A7 Inquiry Made By: Don Clarke/Kent Pecoy&Sons 246-3749 Date of Inquiry: 11/24/14 Reason for Request: New Construction Hook into City Sewer Municipal Sewer Main in Front of Location: Yes No Municipal Storm Drain Available: 5'/Z deep Yes No Size of Sewer Main: Material: Age: Depth of Sewer Main: Length of Sewer Main: Size of Service Connection: Type of Service Connection: Tie-in to Sanitary Main Tie-in to Sanitary Stub Comments: T Citv Requires 6" cleanout installed at City Propertv Lim - Note: If this availability is for new construction this form must be hand delivered to Buildina Inspector. A corresponding"sewer entrance fee"shall be paid prior to making any connection to the municipal sewer system.Arrangements of such installation shall be made with the Northampton Streets Department with a minimum of 5 working days notification. All work shall conform to Northampton Streets Department specifications' ;.L 4 N John Hall / -' Sewer Department cc: Ned Huntley, Director DPW Louis Hasbrouck, Building Commissioner fLAM � t - .,cam DEP1'.RTMENT OF B UTLDITIG INSPECTIONS _ 212 Main Street 6 •Mimicipa2 BuRdin� ;INSPI=CTOR Northamptcm,NL4 01060 LOCATION G� 7 A- _ 7 SQUARE FOOTAGE AMOUNT ,BASEMENT @ .20 1sVFLOOR g.50 �. S iNDFLR @ 30- : lam_ • Y.FLOORS, FINISH ATTIC,GARAGE @ 20' T" Vo DECKTORCF S @ -20 ` I TOTAL-. SECTION 6-CONSTRUCTION SERVICES 8.1 Licensed Construction,/S upervisor: NOt Applicable ❑ Name of License Holder:— K f/4'l A,,L c I/ License Number L(!%tFC �, Address Expiration Date Signattfre XV Telephone 9.Registered Home Improvement Contractor: Not Applicable ❑ Company Name Registration Number J�Sfli,jt� ';/„ !?it��'l Address Expiration Date Telephone L/a' -h/ A( j SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... 1311� No...... ❑ 11. - Home Owner Exem flon The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,_you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature S-T 77 SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ Replacement Windows Alteration(s) Roofing Or Doors D Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [Q Siding[0] Other[pj Brief Descriptign of Proposed Work. /�`c-4/ i 1%AZ2!/G.4Z Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a, If New house and or addition to existing housing, complete the following_ a. Use of building :One Family Two Family Other b. Number of rooms in each family unit: S Number of Bathrooms "? c. Is there a garage attached? 1U6 d. Proposed Square footage of new construction. /,.�`/S� Dimensions v?� X �3 7 e. Number of stories? f. Method of heating?la/'K //-e Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. ycs Masscheck Energy Compliance form attached? !�S h. Type of construction �'Jefe) i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes _,//No j. Depth of basement or cellar floor below finished grade `. k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer ✓` Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT ACc- as Owner of the subject property hereby authorize to act on my behalf, in all matteQ relative to work authorized by this building permit application. Signature of Owner Date as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pairs and penalties of perjury. Print Name Signature of Owner/Agent Date t Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front - Side L: R: L R: Rear _ Building Height Bldg. Square Footage % Open Space Footage % (Lot area minus bldg&paved -kin #of Parking Spaces Fill: volume&Location) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? fM NO DONT KNOW 0 YES 0 IF YES, date issued:. IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DONT KNOW 0 YES 0 IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO " DONT KNOW ® YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained ® , Date Issued: C. Do any signs exist on the property? YES ® NO 0 IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES ® NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES 0 NO 0 IF YES,then a Northampton Storm Water Management Permit from the DPW is required. r Department use only City of Northampton Status of Permit: Building Department Curb Cut/Driveway permit DEC ' 7 204 212 Main Street Sewer/Septic Availability Room 100 Water/Well Availability �---e tons Northampton, MA 01060 Two Sets of Structural Plans EI tnc. i ;pion 413-587-1240 Fax 413-587-1272 PIoUSite Plans Other Specify APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: to 7 7 This section to be completed by office Map Lot /�!z Unit �` Zone Overlay District � (;j�';�',y fi?��l�C/mot ����.� E�r`L'�C� Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: f'/ / %�i�� d <S ✓J C��'S'l� `[ Ile,K l f S '°Z-�j r t;r�' f Name(Print) Current Mailing Address: Telephone Signature 2.2 Authorized A ent: Name( rint)' Current Mailing Address: Sig ature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by rmit applicant 1. Building (a)Building Permit Fee ��3rooc� 2. Electrical ` 066 (b)Estimated Total Cost of Construction from 6 3. Plumbing D V Building Permit Fee � C 4. Mechanical(HVAC) 5. Fire Protection /6-14).40 6. Total=(1 +2+3+4+5) Ja y t"m j Check Number G This Section For Official Use Only Building Permit Number: Date Issued: Signature: Building Commissioner/Inspector of Buildings Date File#BP-2015-0674 APPLICANT/CONTACT PERSON KENT PECOY&SONS CONSTRUCTION INC ADDRESS/PHONE 215 BALDWIN ST WEST SPRINGFIELD (413)781-7008 PROPERTY LOCATION 99 MOSER ST-LOT 7 MAP 38A PARCEL 139 ZONE PV THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid Typeof Construction: CONSTRUCT 2 STORY SINGLE FAMILY RESIDENCE W/PORCH New Construction Non Structural interior renovations Addition to Existin Accessory Structure Building Plans Included: Owner/Statement or License 052589 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INI79AHATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management m lay xog re`MBuffgii icial' Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of Planning&Development for more information. 99 MOSER ST-LOT 7 BP-2015-0674 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 38A- 139 CITY OF NORTHAMPTON Lot:- PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category:New Single Family House BUILDING- PERMIT Permit# BP-2015-0674 Project# JS-2015-001293 Est.Cost: $329000.00 Fee: $704.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: KENT PECOY & SONS CONSTRUCTION INC 052589 Lot Size(sq. ft.): 4378.00 Owner: KENT PECOY&SONS CONSTRUCTION INC zoning: PV Applicant: KENT PECOY & SONS CONSTRUCTION INC AT. 99 MOSER ST - LOT 7 Applicant Address: Phone: Insurance: 215 BALDWIN ST (413) 781-7008 WC WEST SPRINGFIELDMA01089 ISSUED ON.1/5/2015 0:00:00 TO PERFORM THE FOLLOWING WORK:CONSTRUCT 2 STORY SINGLE FAMILY RESIDENCE W/PORCH POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Sisnature: FeeTvpe: Date Paid: Amount: Building 1/5/2015 0:00:00 $704.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner