17D-084 (3) Air Leakage / ? P Property Organization HERS 5 Garfield Ave Center for EcoTechnology Confirmed Florence, MA 01062 413-586-7350 12/16/14 John Saveson Rating No:13-365 Weather:Northampton, MA Rater ID:1911963 5 Garfield Ave Builder 13-365 5 Garfield Ave Florence Pioneer Valley Habitat finaLblg Whole House Infiltration Blower Door Test Heating Cooling Natural ACH 0.101 0.07 ACH 50 Pascals 1.61I 1.61 CFM 25 Pascals 1751 175 CFM 50 Pascals 275 275 Eff. Leakage Area(sq.in) 15.1 15.1 Specific Leakage Area 0.00008 0.00008 ELA/100 sf shell (sq.in) 0.50 0.50 Duct Leakage Leakage to Outside Units CFM @ 25 Pascals CFM25 / CFMfan CFM25 /CFA j CFM per Std 152 CFM per Std 152 / CFA CFM @ 50 Pascals Eff. Leakage Area(sq.in) Thermal Efficiency Total Duct Leakage Units Total Duct Leakage Ventilation Mechanical Exhaust Only Sensible Recovery Eff. (%) 0.0 Total Recovery Eff. (%) 0.0 Rate (cfm) 44 Hours/Day 24.0 Fan Watts 5.7 Cooling Ventilation Natural Ventilation ASHRAE 62.2 - 2010 Ventilation Requirements For this home to comply with ASHRAE Standard 62.2 -2010 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings, a minimum of 43 cfm of mechanical ventilation must be provided continuously, 24 hours per day. Alternatively, an intermittently operating mechanical ventilation system may be used if the ventilation rate is adjusted accordingly. For example, a 86 cfm mechanical ventilation system would need to operate 12 hours per day, as long as the system operates to provide required average ventilation once each hour. REM/Rate- Residential Energy Analysis and Rating Software v14.5.1 This information does not constitute any warranty of energy cost or savings. ©1985-2014 Architectural Energy Corporation, Boulder, Colorado. l -7 f age Builder Name: Pioneer Valley Habitat Rating Company: Center for EcoTechnology Permit Date/Number:11/18/13, BP-2014-0588 Rater Identification Number: 1911963 Home Address:5 Garfield Ave Rating Date: 12/16/14 Florence, MA 01062 Version: 3.0 t: e ® w s Thermal Enclosure System Water Management System A complete thermal enclosure system that 1014L A comprehensive water management system includes comprehensive air sealing,quality- to protect roofs,walls,and foundations. installed insulation and high-performing y I] windows to deliver improved comfort and u Flashing,a drainage plane,and site grading to lower utility bills. move water from the roof to the ground and Air Infiltration Test: Htg:275 Cig:275 CFM50 then away from the home. Primary Insulation Levels: Water-resistant materials on below-grade walls and underneath Ceiling:R-66.7 slabs to reduce the potential for water entering into the home. AGWall:R-29.3 Slab:R-15.0 Management of moisture levels in building materials during Primary Window Efficiency: construction. U-Value:0.300,SHGC:0.220 Heating,Cooling,and Ventilation System I Energy Efficient A high-efficiency heating,cooling system, Lighting and Appliances and ventilation system that is designed and Energy efficient products to help reduce utility installed for optimal performance, bills,while providing high-quality performance. Total Duct Leakage: ENERGY STAR Qualified Lighting: 95% NA ENERGY STAR Qualified Appliances and Fans: Duct Leakage to Outdoors. Refrigerators:0 Dishwashers:0 NA Ceiling Fans:0 Exhaust Fans:0 Primary Heating(System Type•Fuel Type•Efficiency): Primary Water Heater(System Type•Fuel Type•Efficiency): Fuel-fired hydronic distribution,Propane,94.0%EFF. Instant water heater,Propane,0.94 EF,0.0 Gal. Primary Cooling(System Type•Fuel Type•Efficiency). None The certificate provides a summary of the major energy efficiency and other construction features that contribute HERS'Index to this home earn the ENERGY STAR,including ng flsHome Energy Rating System(HERS)score,as determined through independent inspection and verification performed by a trained professional.The home Energy Rating System is a nationally-recognized uniform measurement of the energy efficiency of homes. Zero Energy Reference Existing Note that when a home contains multiple performance levels for a particular feature(e.g.,window efficiency or gy g insulation levels),the predominant value is shown.Also,homes may be candied to earn the ENERGY STAR Home Home Homes using a sampling protocol,whereby one home is randomly selected from a set of homes for representative A (v inspections and testing.In such cases,the features found in each home within the set are intended to meet or enxeed the values presented on this certificate.The actual values for your home may differ,but offer equivalent or be tlerperformance. 7 - Th' eedficate was primed using REM/Rate 04.5.1. Less 0 0 0 o O o 0 0 0 0 0 0 0 0 0 ®19&5-2014 Architectural Energy Corporation,Boulder,Colorado. More Energy Energy This Home - - WM3 RUNEr '.'_ :'RIAM1?55�'S59SSk�H. b'dM utafi + anr!.':,:p.ut,.r a^sYae�£v.nnrS.w'i*�4?YNnu«.,.F+i.:_ha., '�'+z`k+�€f*k s`4ea�Sf'+4Y.'X mv?k'�%kk�m.�i�rS2FtAdn"d ">ffi3` ku.,. Home Energy Rating Certificate Regiumber 13-365862 Rating Number 13-365 Certified Energy Rater John Saveson 5 Garfield Ave Rating Date 12/16/14 Florence, MA 01062 Rating Ordered For Estimated Annual Energy Cost Use MMBtu Cost Percent 5 Stars Plus Heating 19.7 $707 40% Confirmed y HERS Index: 44 Cooling 0 $0 0% V` Hot Water 11.6 $414 24% V Lights/Appliances 13.5 $633 36% © General Information Photovoltaics -0.0 $.0 -0% Conditioned Area 1280 sq. ft. House Type Single-family detached Service Charges $0 0% Conditioned Volume 10240 cubic ft. Foundation Slab Total 46.5 $1754 100% Bedrooms 3 Criteria Mechanical Systems Features This home meets or exceeds the minimum criteria for the following: 1. Heating: Fuel-fired hydronic distribution, Propane, 94.0% EFF. Water Heating: Instant water heater, Propane, 0.94 EF, 0.0 Gal. Duct Leakage to Outside NA Ventilation System Exhaust Only: 44 cfm, 5.7 watts. Programmable Thermostat Heat=Yes; Cool=No Building Shell Features Ceiling Flat R-66.7 Slab R-5.0 Edge, R-10.0 Under Sealed Attic NA Exposed Floor NA Vaulted Ceiling NA Window Type U-Value: 0.300, SHGC: 0.220 Above Grade Walls R-29.3 Infiltration Rate Htg: 275 Clg: 275 CFM50 Center For EcoTechnology Foundation Walls NA Method Blower door test 320 Riverside Dr 1 A Lights and Appliance Features Northampton, MA 01062 g PP ance 413-586-7350 Percent Interior Lighting 94.70 Range/Oven Fuel Electric www.CETontine.org Percent Garage Lighting 100.00 Clothes Dryer Fuel Electric Refrigerator(kWh/yr) 370.00 Clothes Dryer EF 3.01 Dishwasher Energy Factor 0.00 Ceiling Fan (cfm/Watt) 0.00 REM/Rate-Residential Energy Analysis and Rating Software 04.5.1 This information does not constitute any warranty of energy cost or savings. O 1985-2014 Architectural Energy Corporation, Boulder, Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. —————————-- -------------- ------ ---------------- wWry/ FP-006 (Rev.04112) PERMIT City or Town: Ff DIG SAFE NUMBER Date: J09 - Start Date: t Permit Number(if applicable): In accordance with the provisio of M.G.L. Chapter 148, as provided in A this permit is granted (Full Name of Person,Firm or Corporation) for I L 2 Restrictions: at �r, (Street and#or Describe Locafion forAdequate Iden'tification) Fee Paid$ This permit will expire on jj Signature of Official Granting Permit: Title This permit must be conspicuously posted up®n the premises The Commonwealth of Massachusetts a. City of Northampton Certificate of Occupancy In accordance with 780 CMR, (The 8th Edition of the Massacliusetts State Building Code) this Certificate of Occupancy is issued to the premise or structure or part thereof as herein identified. Identify Naine of Building of Space Within Certificate No. Issued to Pioneer Valley Habitat for Humanity BP-2014-0588 Permit Identify property address including street number, name, city or town and county Located at 5 Garfield Avenue Florence, MA 01062 Use Group Classification(s) Single Family Residential R3 This Certificate of Occupancy is hereby issued by the undersigned to certify that the premise, structure or portion thereof as herein specified has been inspected for general fire and life safety features. This certificate shall allow for the use as herein described and in conformance with any and all conditions as identified below. It shall be posted in a conspicuous place within the space as directed by the undersigned. Failure to post the certificate,failure to comply with conditions or, tampering with the contents of the certificate is strictly prohibited. Conditions of Use Single Family Name of Municipal Date of Final Map/Plot: Building Official Kyle J. tt Inspection Date 17D-084 12/22/2014 Signature of Municipal Date of Map Building Official Issuance Date 12/22/2014 Lot MAY 2 8 201M --------------------- i i 5 GARFIELD AVE BP-2014-0588 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 17D-084 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category:New Single Family House BUILDING PERMIT Permit# BP-2014-0588 Project# JS-2014-000988 Est.Cost: $137518.00 Fee: $593.60 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: MICHAEL BROAD 046013 Lot Size(sq ft.): 11412.72 Owner: PIONEER VALLEY HABITAT FOR HUMANITY Zonine: Applicant: PIONEER VAI_I-FY_HABITAT FOR HUMANITY AT: 5 GARFIELD AVE Applicant Address: Phone: Insurance: P O BOX 60642 (413) 586-5430 FLORENCEMA01062 ISSUED ON:11/18/2013 0:00:00 TO PERFORM THE FOLLOWING WORK.-CONSTRUCT 2 STORY SINGLE FAMILY HOUSE/PORCH POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground:''' 1 f Service: g1A11 y i Meter: a s ?J�/ Footings: f /°� ( Rough: �/7 �, cough: House# Foundation:;, /4/1�J Driveway Final: Final: Final: (�+ 777777 �. Rough Frame: ,. r G as:rO z, ,Fire Deaartment Fireplace/Chimney: Bough: Oil: Insulation: e7, 31 Final: l f Smoke• 11141111 Final: GV CPO- THIS PERMIT MAY BE REVOKED BIFTHE CITrV OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REG A ONS. A.;. h4xv Certificate of Occupancy Si nature: FeeType: Date Paid: Amount: Building 11/18/2013 0:00:00 $593.60 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner