Loading...
11A-093 (diffusion).A vapor retarder or barrier is effective even if there are some holes or gaps, however an air barrier has to be absolute and complete. If air can leak through an electrical device or through a crack it follows the path of least resistance and carries 99%of the moisture in a structure.This is evident every time one exposes fiberglass insulation and finds black on the insulation that has filtered dirt out of the air moving through the insulation. 780 CMR R601.2 for vapor retarders and Table N1102.4.2 for air sealing requirements. 38. Unvented attic assemblies. Hot roofs are allowed, but have specific requirements 780 CMR R806.4. 39. Deck ledgers and post must be appropriately attached, bolts or lags. 780 CMR R502.2.2.1 Note:Thrul-oks are engineered for post attachment supporting a railing. Lateral attachment is required for each deck per section 502.2.2.3. 40. Smoke and CO detectors as required. 780 CMR R314 and R315. a. Smokes in each bedroom,within 10'of a bedroom door, and at the bottom of a stair leading to a finished floor above. b. CO within 10' of bedroom doors, at each level, for every 1500 sgft, (plumbing code in the mechanical room)except if there are no fossil burning fuels or attached garage. c. Heat detector in attached garage, and other large unfinished unconditioned spaces. 41. Closets beneath stair which have doors must be drywalled with %". 780 CMR R302.7 42. If there is mechanical equipment or a combustible roof, 30 sqft of space, and 30" measured from top of ceiling joist to bottom of rafters an attic access of minimum RO of 22" x 30" is required to be located in an accessible place. It must be insulated equal to surrounding,gasketed, and secured in place. 43. Clearances above gas stoves and cook tops burners is 24" to non-combustible or 30" to combustibles. Relevant items must be submitted to the building department for approvals before inspections and or Certificates of Occupancy can be issued. Feel free to call if you have any questions. My telephone number is 587-1240 and office hours are Monday through Friday, 8:30 am to 4:30 pm, excepting we close for walk-ins at 12:00 noon on Wednesdays. My email address is: cmiller(d_)northamptonma.gov Thank you for your cooperation o ese matters. 6� --- Chuck Miller City of Northampton Assistant Commissioner and Zoning Enforcement 22. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9", maximum riser 8%", maximum overall variance for the run is 3/8",4" sphere rule on risers except where the total rise is 30" or less 780 CMR R311.7.4.3 Exception,4 3/8" on balustrade, 6" in the triangle. Graspable rail 1%" minimum and 2" maximum rail, height minimum 34" maximum 38", required for 4 or more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling height from nosing. Rails must be continuous and returned to the wall if not to newel post. 780 CMR R311.7. 23. Guards 36" minimum height above walking surface, a bench is a walking surface, required for more than 30" above floor or grade within 36",4" sphere rule. 780 CMR R312.1. 24. Floor joist systems that are not equal to 1%" nominal dimension must be covered with%" drywall or 5/8" wood structural panel or equivalent with some exceptions. 780 CMR R501.3 25. Educate the plumber and electrician about maximum notch and hole sizes, and placement. 780 CMR R502.8 and R602.6. In bearing studs holes not larger than 40%of a stud no closer than 5/8 to the edge, In interior non-bearing studs holes not larger than 60%of a stud no closer than 5/8 to the edge, or holes in joist are a maximum 1/3 the depth not closer than 2"from the top or bottom or to any other hole. Notches are different. 26. Drilling or notching of more than 50% of the wall plate width of an exterior wall or load bearing partition requires a 16 GA 1 %" strap across the area and 6" beyond each side with 8- 10nd nails.780 CMR R602.6.1 27. Dryer ducts must terminate outside of the building, have a backdraft damper, cannot include a screen, and require 3' clearance from windows. 780 CMR M1502.3 28. Dryer duct transition is limited to 8' of aluminum flex, must be exposed, and the proper UL listing.780 CMR M1502.4.3 29. Dryer duct maximum equivalent length is 25' less 5' per 900 elbow or per manufacturer's specs. 780 CMR M1502.4.4.1, no screwed connections. 30. Dryer ducts when concealed must have a permanent label or tag within 6' of the duct connection 780 CMR M1502.4.5 31. Markup air is required for any exhaust hood over 400 CFM. 780 CMR M1503.4 32. Fireplaces require all combustion air be provided from the exterior and below the firebox, duct work maintaining 1" clearance for 5'from the duct outlet for all fireplaces and airtight doors.2009 IECC 402.4.3 33. Fire and draft stopping shall be completed before rough inspection.Typical locations,top (ceiling)and bottom (floor) plates, soffits, and every 10'within enclosed cavities. 780 CMR R302. 34. Ignition barriers are required over all thermal plastics and must be in place before final.780 CMR R316. 35. Dwelling/Garage fire separation.An attached garage (within 3' of main structure) is required to have%" drywall on the garage side of the separation wall and if there is a finished space above the garage all walls must have%" drywall and the ceiling 5/8" drywall. 780 CMR R302.6 36. Energy aspects shall comply with the stretch energy code.780 CMR Appendix 115AA or 2009 IECC. a. An initial HERS evaluation is required including insulation levels anticipated. b. A final HERS evaluation confirming code requirements have been met including duct testing. c. A signed copy of the Thermal Bypass Checklist. d. Energy information including mechanical equipment posted on the electric panel. e. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy Star Windows and the Thermal Bypass Checklist. Duct blast testing when practicable. f. All band joist insulation must be enclosed within an air tight cavity, which you must create. 37. Vapor retarders. Although these are still in the code with some exceptions, one must understand that there is a difference between a vapor retarder and barrier and an air barrier.An air barrier is intended to stop air flow (convection) a vapor retarder or barrier is intended to stop molecular moisture transfer 5. Through wall form ties must be removed from both faces and patched with hydraulic cement.780 CMR R406.2 of amendments. 6. Foundation anchor bolts must be %" and be embedded a minimum of 7" into the concrete. 10" bolts! 780 CMR R403.1.6 7. CMU foundations require 3/8" parging before damp proofing.780 CMR R406.1 see exceptions. 8. Emergency escape is required out of every basement whether habitable or not, each bedroom and walk- in attics. 780 CMR R310.1 9. Crawl spaces can be treated in three different ways,vented (poor idea), exhausted (similar to exhaust only systems), or treating the space with supply and return. See 780 CMR R408 10. Ceiling joist are intended to prevent spread,once raised above the wall plate they become rafters ties and may require up sizing of rafters and increased nailing for example with a 4" slope 8-16nd common are required at each connection. 780 CMR R802.3.1. When there is neither of these a structural ridge is required with a load path to the foundation. 11. Steel straps over the ridge or 1x4 minimum collar ties are required 4' OC in the upper 1/3rd 780 CMR R802.3.1 12. Ridge boards must be the full depth of the cut. 780 CMR R802.3. 13. A complete window and header schedule is required. 780 CMR Table R502.5 for header sizing and number of jack studs required. 14. All framing materials which are not code prescriptive must have stamped engineering. a. LVLs b. Hoist and or Floor Truss c. Roof truss 15. All I-Joist need to be protected from fire with%drywall or 5/8 wood structural panel. (R501.3) 16. A braced wall plan identifying appropriate braced wall areas where required (R301.1) and braced wall method being used. 780 CMR 602.10. a. Garage corners and large corner window/door layout may require special solutions. b. All corners must be appropriately attached to the foundation. c. When using PFH (R602.10.3.3) or PFG (R602.10.3.4)the nailing requirement is 4" and 3" respectively using 8d common nails or galvanized box nails. PNEUMATIC nails must be full headed with the temper and shank sizing meeting the strict code requirement. 17. When nailing sheathing make sure your pneumatic nailers' pressure is properly set. Nails set too deep perforate the sheathing weakening it and contribute to building damage in high wind events. 18. Ceiling heights minimum 7'for habitable spaces, 6'8" for bathrooms includes tub/shower area if a shower head is used, 6'8" for basements, 6'4" at beams/ducts. 780 CMR R305.1. MA amended 19. Hazardous glazing locations, within 24" of a door, or within 60" of a stair, or across from hot tubs,spas, bathtubs within 60" if not 60" above the walking surface, and other locations. 780 CMR R308.4 20. Windows over 72" above grade with the opening less than 24 above the finished floor shall meet the 4" sphere rule.Order restrictors. 780 CMR R612.2 21. Egress and emergency escape requirements shall be strictly met. a. Basements, habitable attics, and all sleeping rooms require emergency escape.780 CMR R310 b. Windows within 44" of floor, DH 3.3 sqft min window size, Casement 20"x41" exception 5 sqft at 15t floor. Minimum clear opening 20"x24" or 24"x20". 780 CMR R310.1.1 c. Two doors remote as possible at the normal level of travel, opening measured from the face of the slab to the stop with door at 90 degrees,one 32" and one 28" minimum 78" high.780 CMR R311.2 d. Landing at each door 36" out and the width of the door minimum 36", maximum step 7 %" from the top of the threshold and only in-swinging doors. 780 CMR R311.3 _ City of Northampton ' Massachusetts �� j7 +. -A fr "k DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street • Municipal Building �. s Northampton, MA 01060 INSPECTOR Ed Jazab December 9, 2014 9 Shepherds Hollow Leeds, MA 01053 Subject Location: 40 Chestnut Avenue Map Block: 11A-093 Mr.J aza b Your building permit application dated 11-5-14 and structural plans dated 12-5-14 have been approved as drawn, noted, and per this memo.All work must meet all applicable codes whether noted or not included within this memo. Please follow up on the following items: These items will need to be accomplished as the project moves forward and before rough inspections; 1. Any changes from the plans the permit was issued with require a SK submitted showing changes, approvals are not automatic. 2. Footings must be properly placed and an appropriate size to accommodate all loading as designed by RK Miles.The two loads at the head of the basement stair require a substantial footing which should include reinforcement.Assumed bearing is 2000 Ibs per SQFT. 3. HERS final ratings, duct blast results, and a signed Thermal Bypass Checklist. 4. Smoke, Heat and CO detectors throughout the structure to current building codes. 5. An emergency escape window is required within every bedroom, basement, and walk-in attics. 6. Tempered glazing is required at all hazardous locations. 7. All load paths must be continuous from the top down and land on appropriate bearing. 8. The door from the rear porch to the garage must open to a landing. 9. Braced wall detailing for the garage section must be followed completely and correctly. 10. A bulkhead is assumed to be included in the location of the deleted fireplace. 11. Any roof sections where rafters are not tied across the building at the top of the wall plates may require structural ridges. Note:July 1 begins enforcement of the 2012 IECC with MA amendments and fire protection for non- dimensional lumber floor system frames,the new Stretch Code is pending. As of August 4th 2011 the 8th Edition MA code is the 2009 IRC with MA amendments. In the following are some generic requirements which seem to be problematic. This is not intended to be comprehensive, nor is it a substitute for purchasing and reading the MA codes. Read only international codes are available on line at.http://publicecodes.cyberregs.comZicod/one must also consider the MA amendments to these codes which can be found at www.mass.gov/dps/``bbrs . The current relevant building codes are: 2009 IBC, 2009 IEBC, 2009 IMC, 2009 IRC, 2009 or 2012 IECC,AA115, MA amendments. 1. Structures shall conform to 780 CMR 8th Edition 1 and 2 family building codes with MA amendments. 2. Grading plan for structures being constructed required. 780 CMR R401.3 for drainage requirements. 3. A basement drainage system is required in all basements 780 CMR R405.2.3. except those in group I soils (table R405.1) 4. Foundations that retain earth and enclose interior space require damp proofing 780 CMR R406.1.or if high water table or severe soils waterproofing 780 CMR R406.2. City of Northampton Mail-40 Chestnut Ave https://mail.goo-le.com/mail/u/O/?ui=2&ik=3921lafc3d&view=pt&se... Charles Miller<cmiller @northamptonma.gov> 40 Chestnut Ave Ann Furciniti <afurciniti @northamptonma.gov> Mon, Nov 24, 2014 at 1:10 PM To: cmiller @northamptonma.gov Dear Chuck: Writing to let you know that Pat Melnik did apply for Water & Sewer avail's. Because of people being out for the holiday, I am unable to get a copy of Sewer until next week. Water dept will send one up to me, but he did apply along with his driveway. Thanks Ann (City of Northampton E-mail is a public record except when it falls under one of the specific statutory exemptions.) 1 of 1 11/24/2014 2:52 PM CITY OF NORTHAMPTON,MASSACHUSETTS w DEPARTMENT OF PUBLIC WORKS 125 Locust Street t Northampton, MA 01050 rt 413-587-1570 Fax 413-587-1576 Edward S. Huntley, P.E. Director ASSIGNMENT OF HOUSE NUMBER Street: Chestnut Avenue Assessors Map: Map 11A,Lot 93 i House Number: 40 Date: November 3,2014 Remarks: This address is assigned to a new building lot on Chestnut Avenue,also identified as"Lot#2"on an ANR plan entitled Plan of Land in Northampton Massachusetts Owner: Patrick J.Melnik,Jr.by Richard J.LaBarge, Sr.,PLS dated December 26,2013.An address was requested by the Owner for permitting purposes for the construction of a single family dwelling. rames a, r al Dispatch Board of Health Water Division Tax Collector Sewer Division National Grid Streets Division Verizon Telephone inspectors Comcast Assessors Columbia Gas of Massachusetts Police Department Post Office(Northampton) James Thompson(GIS Coordinator) Post Office(Easthampton) Registrar of Voters School Department(Joy Winnie) Owner/Applicant: Patrick Melnik,Jr. 110 King Street Northampton,MA 01060 WHouse Numbers\Chestnut Avenue\#40 Chestnut Avenue.doo Registry ID: Rating Number: HERS-386 &It 11 Certified Energy Rater: Matt Turcotte Rating Date: 11/10/14 40 ChestnutAve Rating Ordered For: Leeds,MA 01053 Estimated Annual Energy Cost Projected Rating 5 Stars Plus Use MMBtu Cost Percent Projected Rating: Based on Plans, Field Confirmation Required Heating 57.4 $894 40% Uniform Energy Rating System Energy Eff icient Cooling 3.3 $166 8% Hot Water 15.3 $215 10% 1 Star 1 Star Plus 2 Stars 2 Stars Plus 3 Stars 3 Stars Plus 4 Stars 4 Stars Plus 5 Stars 5 Stars Plus Lights/Appliances 20.7 $943 43% 500-401 400-301 300-251 250 201 200-151 150-101 100-91 90-86 85-71 70 or Less Photovoltaics -0.0 $-0 -0% HERS Index 70 Service Charges $0 0% 1ta1"IEtCtttatlat fM Total 96.7 $2219 100% Conditioned Area: 1730 sq.ft. HouseType: Single-family detached - z C WN onditioned Volume: 22276 cubic ft. Foundation: Conditioned basement "" °° This home meets or exceeds the minimum Bedrooms 3 , �� ��\ ,,� � criteria for all of the following: 1lyecft� � terns 3 `a�fy � ., f � ,...,,...,w::\.. W .._.,w...._, 'a"�btt 3,isa„kkih. S��uA 'a�.r�.,.,�:,., si3 ✓1.E 7.a„«� ,E_a:.,4...�' �vR.�i�'_,.��.. L..:s. .�....,..., Heating: Fuel-fired air distribution,Natural gas,95.0 AFUE. Cooling: Air conditioner,Electric,13.0 SEER. Water Heating: Instant water heater,Natural gas,0.82 EF,0.0 Gal. Duct Leakage to Outside: 103.80 CFM25. Ventilation System: Exhaust Only:47 cfm,7.0 watts. Programmable Thermostat: Heating:Yes Cooling:Yes Ceiling Flat: R-40.8 Slab: R-0.0 Edge,R-0.0 Under Sealed Attic: NA Exposed Floor: R-30.0 Vaulted Ceiling: NA Window Type: U-Value:0.300,SHGC:0.250 Above Grade Walls: R-19.3 Infiltration Rate: Htg:2.50 Clg:2.50 ACH50 � Foundation Walls: R-10.1 Method: Blower door test K N a N a .. f TITLE Percent Interior Lighting: 80.00 Range/Oven Fuel: Natural gas Company Percent Garage Lighting: 80.00 Clothes Dryer Fuel: Electric Address Refrigerator(kWh/yr): 575.00 Clothes Dryer EF: 3.01 City,State,Zip Dishwasher Energy Factor: 0.66 Ceiling Fan(cfm/Watt): 0.00 Phone# The Home Energy Rating Standard Disclosure for this home is available from the rating provider. Fax# REM/Rate-Residential Energy Analysis and Rating Software v14.5.1 This information does not constitute any warranty of energy cost or savings. ©1985-2014 Architectural Energy Corporation,Boulder,Colorado. 3 03 1 N4jk 1�{aa a°3 .10 M014 �0� ;o MoN 6 1 I i sgS'L£ M «61,60 L .ZS N ----- cn z v Cy 'v 00 W. l CTS �`� 6s v w N v v O � O 0 0 r V 1 N t i s,6 d 60 f .ZB N ---- --o 1 � 1 ITOS 602`Z 6 z ��� ��' � ? D IIIZI &11IIIIIT z F µ � $ � j1l�assacf�aseffs - DEPARTMENT OF BUILDING INSPECTIONS JNSPECTOR 212 Main Street 0 Municipal Building Northampton,MA 01060 LOCATION SQUARE FOOTAGE AMOUNT ASENMNT :20 '00- ISr FLOOR @.50 LAO 2 V,FLOORS, FINISH ATTIC,GARAGE @.2 0 ( U - DECKTORCHES @ .20 TOTAL. / U The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations W d 1 Congress Street, Suite 100 Boston,MA 02114-2017 www mass gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): EP J_(A r 1 Address: � SH LTH�,9 S Ao t_-a v,-i City/State/Zip: 1--E 1=-9 s , P� • 0!053 Phone#: 413- 222- 4 9 10 Are you an employer? Check the appropriate box: Type of project(required): 1.❑ I am a employer with 4. ❑ 1 am a general contractor and I 6. ®New construction employees (full and/or part-time).* have hired the sub-contractors 2.D] I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g, ❑ Demolition working for me in any capacity. employees and have workers' 9. ❑ Building addition [No workers' comp. insurance comp. insurance.$ required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.E] Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.E] Roof repairs insurance required.] t C. 152, §1(4),and we have no employees. [No workers' 131-1 Other comp. insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. $Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Policy#or Self-ins. Lic. #: Expiration Date: Job Site Address: City/State/Zip: Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certj_fy under the pains and penalties of perjury that the information provided above is true and correct. Si ature: Date: k 1 5 ZD I Phone#: L413 - 2 2 - 4 910 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License # Issuing Authority(circle one): 1.Board of Health 2.Building Department 3. City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder: Ep JR z":vi3 CSFa — o50099 License Number Addre s Expiration Date L-1 175 - 222 - L49 I D Signature Telephone 9.Registered Home improvement Contractor: Not Applicable ❑ Company Name Registration Number Address Expiration Date Telephone SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... ❑ No...... ❑ 11. !- Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size LXA 102- 2 S Frontage Setbacks Front Side L: R: Rear lv r+ Building Height ?, Bldg. Square Footage Open Space Footage % o (Lot area minus bldg&paved �'/�.<� _. .... parking) #of Parking Spaces ' Fill: volume&Location) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO DON'T KNOW 0 YES 0 IF YES, date issued:! IF YES: Was the permit recorded at the Registry of Deeds? NO o DON'T KNOW Q YES Q IF YES: enter Book Page and/or Document#' B. Does the site contain a brook, body of water or wetlands? NO DONT KNOW O YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained 0 , Date Issued: C. Do any signs exist on the property? YES NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES 0 NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES Q NO IKI IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House � Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors D Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [0 Siding[O] Other[0] Brief Description of Propposed Work: J G�G✓ ��i�i�! �. /, — 1/✓ Alteration of existing bedroom Yes No Adding new bedroom Yes No �GO4 GL Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a, if Now house and or addition to existing housing, complete''the following: a. Use of building : One Family X Two Family Other b. Number of rooms in each family unit: 16 Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. / l) Dimensions V e. Number of stories? 2 f. Method of heating? �!/✓; ( 4,S Fireplaces or Woodstoves A/_y Number of each g. Energy Conservation Compliance. ��'� Masscheck Energy Compliance form attached? yG1 h. Type of construction 1v0,9 1,2 2�_&I re i. Is construction within 100 ft. of wetlands? Yes X\No. Is construction within 100 yr. floodplain Yes--k-No j. Depth of basement or cellar floor below finished grade R, k. Will building conform to the Building and Zoning regulations? _Yes No. I. Septic Tank City Sewer Private well City water Supply _ SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT as Owner of the subject property r hereby authorize to act on my behalf, in all matt ative to work authorized by this building permit application. Signature of Qwr Date I, G9 c7AZA& as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. 'L 17 7p, Print Name '�A �A - 11 15 j2o l Signature of O e A ent Date f Northampton tatws'of�Permit. tiMi g Department Curb Ouk'larivewt ipetmlt i' 21 Main Street SewertSeptic`Avaiiak�tlrtj± r`�cti�n --ring ctrlc oom 100 tNaterlUUellflyaability � . ", o pton, MA 01060 Two Sets of,,Structural„Plans phone 413-587-1240 Fax 413-587-1272 RlatlSlte Plaria" r Clther Speplfy >, ;, APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION This section to be completed by office 1.1 Property Address: d yo C hPS 4-n v 71 L AlcC Map _ Lot t./11 Unit___ L C e Zone Overlay District r Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Name(Print) Current Mailing Address: I—e C f �� D(d i3— s8�- 675'v Telephone Signature 2.2 A prized Agent: r 4 1-�i Na in +� Current Mailing Address: LA 13 -- 222 - '49 I0 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by ermit applicant 1. Building /,Iv U (a) Building Permit Fee 2. Electrical / S w (b) Estimated Total Cost of Construction from 6 3. Plumbing - v Building Permit Fee 4. Mechanical(HVAC) / 1 5. Fire Protection 6. Total=(1 +2+3+4+5) 0,Pd Check Number 4) 1160 J Thi Section For Official Use Only Date Building Permit Number: Issued: Signature: Building Commissioner/Inspector of Buildings Date Foo 44T,g.c a r yoke ow,y lea s k II-R,l Y e File#BP-2015-0545 APPLICANT/CONTACT PERSON ED JAZAB ADDRESS/PHONE 9 SHEPHERDS HOLLOW LEEDS (413)222-4910 Q + PROPERTY LOCATION 40 CHESTNUT AVE MAP 1 IA PARCEL 093 001 ZONE THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid Tyneof Construction: CONSTRUCT 2 STORY SFH W/ATT GARAGE/DECK New Construction Non Structural interior renovations Addition to Existing AccessorStructure Building Plans Included: Owner/Statement or License 050099 , ® + 3 sets of Plans/Plot Plan � Q��d�y/rL THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management D itioj3,Delay Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning& Development for more information. 40 CHESTNUT AVE BP-2015-0545 GIS#: ►� COMMONWEALTH OF MASSACHUSETTS Map:Block: I IA-093 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Buildinq DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category:New Single Family House BUILDING PERMIT Permit# BP-2015-0545 Proiect# JS-2015-001042 Est. Cost: $165000.00 Fee: $963.40 PERMISSION IS HEREBY GRANTED TO Const. Class: Contractor: License: Use Group: ED JAZAB 050099 Lot Size(sq. ft.): Owner: MELNIK PATRICK J JR Zoning: Applicant: ED JAZAB AT: 40 CHESTNUT AVE Applicant Address: Phone: Insurance: 9 SHEPHERDS HOLLOW (413) 222-4910 () LEEDSMA01053 ISSUED ON:1211012014 0:00:00 TO PERFORM THE FOLLOWING WORK.CONSTRUCT 2 STORY S F H W/ATT GARAGE/DECK POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Siznature: FeeType: Date Paid: Amount: Building 12/10/2014 0:00:00 $963.40 212 Main Street, Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner