Loading...
23B-046 (236) OrderID: 131401754 1 J 1 i ,`j Page 5 04- 5 nalysis Type: Asbestos Chain of Custody LM Record umaround Time: 6 Hour Green Environmental Consulting, LLC 180 Pleasant Street-Suite 7 Easthampton,MA 01027 Protect info: Send Results To: r Project Name: invoicito: Results to: DH-West Wing dam L� sko dam Lesko roject Number: etum Samples?: Email to: 100912 Ietko@gecenviro-com Project Description: Comments/Special Phone: Pre Renovation Asbestos Inspection instructions: 413) 341-3418 Fa)c 41�) 341-3418 Sample Number ale Location Sample Description i 00912-46A Treatment Room 7 Joint Compound 00912-46B Treatment Room 4 Joint Compound ✓ 00912-46C Large Rehab Room Office Joint Compound 100912-46D Small Rehab Hail Joint Compound t } R i I i : Sampled By: Date: Received By: (l a/Time: Relinquished By: Date/Time: Received in Lab B { a ime: 085 8 OrderlD: 1 i V O 5 4 Page 4 Of'5 nalysis Type: Asbestos Chain of Custody LM Record Turnaround Time: 6 Hour Green Environmental Consulting, LLC 180 Pleasant Street-Suite 7 Easthampton, MA 01027 Proiect Info: Send Results To, Project Name: Invoice to: Results to: DH-West Wing darn L sko Adorn Lesko aject Number: etum Samples?: Email to: 0912 Iesko@gecenviro.com Project Description: Comments/Special P ne: Pre Renovation Asbestos Inspection Instructions: 413) 341-3418 Fa)C V41� 341-3418 Sample Number Sample LocatI2 n Samp le Description 5 100912-42B Treatment Room 7 Skim Coat over Firestop 00912-42C Main Rehab Hall Skim Coat over Firestop a.7 100912-43A Mid Hall B),Elevators Linoleum Small Grey Block c 00912-43B Mid Hall By Elevators Linoleum Smiall Grey Block F0-0912-44A Mid Hall Byi Elevators Linoleum Small Grey Block Mastic 00912-44B Mid Hall By Elevators Linoleum Sm�°6all Grey Block Mastic r 100912-45A Small Reha Hall Sheetrock 100912-45B Treatment Room 7 Sheetrock Sa Date: Received By: to/Time: ate/Tirne: Received in Lab ` i -IU14 to/Time: OrderiD: 1311401754 7 5 4 Page 3 4_6 nalysis Type: Asbestos Chain of Custody LM Record Turnaround Time: 6 Hour Greed Environmental Consulting, LLC 180 Pleasant Street-Suite 7 Easthampton, MA 01027 Proiect Into: Send Results To: Project Name: invoice4 to: Results to: DH-West Wing dam L sko ddm Lesko oject Number: etum mples?: lieSko@gecenviro.com mail to: 0912 Project Description: Comments/Special Phone: Pre Renovation Asbestos Inspection instructions. 413)341-3418 Fa)C 413)341-3418 Sample Number Sample Location Sam le Description 00912-38B Large Rehab Room Office Cove Base/Side Rug Adhesive 1 00912-39A Large Rehab Room Office Cove Base Adhesive Tan ! 00912-39B Large Reh b Room Cove Base Adhesive Tan 100912-40A Treatment Room 5 Rug Adhesive Green 100912-40B Treatment Room 1 Rug Adhesiv Green 00912-41A Large Rehab Room Office Wall Tile Grout k 00912-41B Large Reha Room Office Wall Tile Grout 00912-42A Rehab Waiting Area Skim Coat over Firestop Sa led By: Date: Received By: p Lt e/Time: � U 444a_ ate/Time: Received in Lab By /Time: � tom► By OrderiD: 131401754 Page 2 C+ naiysis Type: Asbestos Chain of Custody ? LM Record Turnaround Time: 6 Hour Green Environmental Consulting, LLC 180 Pleasant Street-Suite 7 Easthimpton,MA 01027 QCoie Info* ;end Results To: i Project Name: invoice to: Results to: 3 DH-West Wing dam Ll sko Adam Lesko oject Number etum ampies?: ---=�le*o@gecenviro.com Emili to: 0912 Project Description: Comments/Special Phone: Pre Renovation Asbestos Inspection instructions: 413) 341-3418 Fax: 415)341-3418 Sample Number S6mlgle t SaMc le Description 100912-34B Back Stairs Linoleum L2 i 00912-35A Back Stairs Linoleum 1_2 Mastic 1 00912-358 Back Stairs Linoleum L21Mastic 00912-36A Small Rehab Hall 2x2 Ceiling Tale 13 00912-368 Main Reba Hal! 12x2 Ceiling Tile 00912-37A Vent Above CEiling Vent Sealant= is 00912-37B Vent Abov' CEiling Vent Sealant 00912-38A Main Reha 6 Hall Cove Base/Side Rug Adhesive Date: Received By: /Time: t ishe Date/Time: Received in Lab By /Time: 0 l OrderlD: 131401754 U 1 1 d " Page 1 nalysis Type: Asbestos Chain of Custody LM r Retard umaround Elms: 6 Hour Green Environmental Consulting,LLC 180 Pleasant Street-Suite 7 Easthampton, MA 01027 Project Info: Send Results To: F ject Name: Invoice to: Results to: -West Wing dam �sko dam Lesko ect Number. etum ampies?: Email to: 12 le'ko@gecenviro.com Project Description: Comments/Special P #ne: Instructions: 413)341-3418 Pre Renovation Asbestos Inspection Fax: 413)341-3418 } Samole Nurn SaEjole Location &mole Description 00912-05D Rehab Waiting Area Grey Firestop off- 00912-05E Treatment Room 7 Grey Firestop 00912-05F Main Rehab Hall Grey Firestop 00912-32A Back Stair; 12" Blue Floor Tile I 100912-32B Back Stair 12" Blue Floor Tile 9 100912-33A Back Stair 12" Blue Floor Tile Mastic 100912-33B Back Stair 12" Blue Floor Tile Mastic 00912-34A Back Stair; Linoleum 1_21 I i S Dater Received By: Date/Tioie: A& /V I list o U Tnn i ga ayr.-----...- t /Time: Received in Lab P�t te/'Time: ,�......._.-- _,.3 �� �Y 214 ay EMSL Analytical, Inc. EMSL Order: 131401754 7 Constitution Way,Suite 107,Woburn,MA 01801 CUstomerlD: GECL78 Phone/Fax: (781)933-84111(781)933-8412 CustomerPO: http://www.EMSL.com bostonlab@gmsl.com ProjectlD: Attn: Adam Lesko Phone: (413)341-3418 Green Environmental Consulting, LLC Fax: (413)341-3419 180 Pleasant St Received: 05/12/14 8:30 AM 3rd Floor, Suite 7 Analysis Date: 5/16/2014 Easthampton, MA 01027 Collected: Pr 'ect: 00912/CDH-West Win Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Non-Asbestos Asbestos Sample Description Appearance % Fibrous % Non-Fibrous % TVDe 00912-44B MID HALL BY Brown 100% Non-fibrous(other) <1% Chrysotile ELEVATORS- Non-Fibrous 131401754-0030 LINOLEUM Homogeneous SMALL GREY BLOCK MASTIC Possible contamination 0091245A SMALL REHAB Gray 5% Glass 93% Non-fibrous(other) None Detected HALL- Fibrous 20% Cellulose 131401754-0031 SHEETROCK Homogeneous 00912458 TREATMENT Brown/White 20% Cellulose 78% Non-fibrous(other) None Detected 1314017540032 ROOM 7- Fibrous 2% Glass SHEETROCK Homogeneous 00912-46A TREATMENT White 100% Non-fibrous(other) None Detected ROOM 7-JOINT Non-Fibrous 131401754-0033 COMPOUND Homogeneous 0091246B TREATMENT White 100% Non-fibrous(other) None Detected ROOM 4-JOINT Non-Fibrous 131401754-0034 COMPOUND HOrnOgeneOUS 0091246C LARGE REHAB White 20% Cellulose 80% Non-fibrous(other) None Detected ROOM OFFICE- Fibrous 131401754-0035 JOINT Homogeneous COMPOUND 0091246D SMALL REHAB White 100% Non-fibrous(other) None Detected HALL-JOINT Non-Fibrous 131401754 0036 COMPOUND HOR10ger1i30US Analyst(s) r Fievel Lam(19) Steve Grise,Laboratory Manager Sean Ryan(17) or other approved signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NIST or any agency of the federal government. Non friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy,precision and uncertainty data available upon request.Unless requested by the client,building materials manufactured with multiple layers(.e.linoleum,wallboard,etc.)are reported as a single sample.Reporting limit is 1% Samples analyzed by EMSL Analytical,Inc.Woburn,MA NVLAP Lab Code 101147-0,CT PH-0315,MA AA000188,RI AAL-107T3 and VT AL357102 Initial report from 05116/2014 14:15:38 Test Report PLM-7.28.9 Printed:5/16/2014 2:15:38 PM THIS IS THE LAST PAGE OF THE REPORT. 5 EMSL Analytical, Inc. EMSL Order: 131401754 7 Constitution Way,Suite 107,Woburn,MA 01801 CustomerlD: GECL78 Phone/Fax (781)933-8411/(781)933-8412 CustomerPO: htto://www,EMSL.com bostoniati emsl.com ProjectlD: Attn: Adam Lesko Phone: (413)341-3418 Green Environmental Consulting, LLC Fax: (413)341-3419 180 Pleasant St Received: 05/12114 8:30 AM 3rd Floor, Suite 7 Analysis Date: 5/16/2014 Easthampton, MA 01027 Collected: Project: 00912/CDH-West Win Test Report: Asbestos Analysis of Bulk Materials via EPA 600/13-931116 Method using Polarized Light Microscopy Non-Asbestos Asbestos Sample Description Appearance % Fibrous % Non-Fibrous % Type 00912-42A REHAB WAITING White 100% Non-fibrous(other) None Detected AREA-SKIM Non-Fibrous 131401754-0024 COAT OVER HOfTlOgeneOUS FIRESTOP 00912-42B TREATMENT White 100% Non-fibrous(other) None Detected ROOM 7-SKIM Non-Fibrous 131401754-0025 COAT OVER Homogeneous FIRESTOP 00912-42C MAIN REHAB White 100% Non-fibrous(other) None Detected HALL-SKIM Non-Fibrous 131401754-0028 COAT OVER Homogeneous FIRESTOP 00912-43A MID HALL BY Gray 5% Cellulose 70% Non-fibrous(other) 25% Chrysotile ELEVATORS- Fibrous 131401764-W27 ELEVATORS SMALL GREY Homogeneous BLOCK 00912-43B MID HALL BY Gray 5% Cellulose 70% Non-fibrous(other) 25% Chrysotile ELEVATORS- Fibrous 131401754-0028 LINOLEUM HOrtl0gef1e0US SMALL GREY BLOCK 00912-44A MID HALL BY Brown 100% Non-fibrous(other) None Detected ELEVATORS- Non-Fibrous 131401754-0°29 LINOLEUM Homogeneous SMALL GREY BLOCK MASTIC Analyst(s) F1evel Lam(19) Steve Grise,Laboratory Manager Sean Ryan(17) or other approved signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client.This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimeldc reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy,precision and uncertainty data available upon request.Unless requested by the client,building materials manufactured with multiple layers(.e.linoleum,wallboard,etc.)are reported as a single sample.Reporting limit is 1% Samples analyzed by EMSL Analytical,Inc.Woburn,MA NVLAP Lab Code 101147-0,CT PH-0315,MA AA000188,RI AAL-10773 and VT AL357102 Initial report from 05/16/2014 14:15:38 Test Resat PLW7.28.9 Printed:5/16/2014 2:15:38 PM 4 EMSL Analytical, Inc. EMSL Order: 131401754 7 Constitution Way,Suits 107,Woburn,MA 01801 CUStomerlD: GECL78 PhonelFax: (781)933-8411/(781)933-8412 CustomerPO: htto://www.EMSL.com bostoniabOemsl.com ProjectlD: Attn: Adam Lesko Phone: (413)341-3418 Green Environmental Consulting, LLC Fax: (413)341-3419 180 Pleasant St Received: 05/12/14 8:30 AM 3rd Floor, Suite 7 Analysis Date: 5116/2014 Collected: Easthampton, MA 01027 Project: 00912/CDH-West Win Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Non-Asbesto Asbesto Sample Description Appearance -Fibrous % TVDe 00912-38B LARGE REHAB Brown 3% Cellulose 97% Non-fibrous(other) None Detected ROOM OFFICE- Non-Fibrous 131401754-0017 COVE BASE! Homogeneous SIDE RUG ADHESIVE 00912-39A LARGE REHAB White 100% Non-fibrous(other) None Detected ROOM OFFICE- Non-Fibrous 131401754-0018 COVE Homogeneous BASE/ADHESIVE TAN 00912-39B LARGE REHAB White 100% Non-fibrous(other) None Detected ROOM-COVE Non-Fibrous 131401754.0019 BASE/ADHESIVE Hl)ntOgeneOUS TAN 00912-40A TREATMENT Green 5% Synthetic 95% Non-fibrous(other) None Detected ROOM 5-RUG Fibrous 1314017S4-0020 ADHESIVE Homogeneous GREEN 00912-40B TREATMENT Green 5% Synthetic 95% Non-fibrous(other) None Detected ROOM 1 -RUG Non-Fibrous 131401754-0021 ADHESIVE Homogeneous GREEN 0091241A LARGE REHAB White 100% Non-fibrous(other) None Detected ROOM OFFICE- Non-Fibrous 1314017540022 WALL TILE Homogeneous GROUT 00912-41B LARGE REHAB White 100% Non-fibrous(other) None Detected ROOM OFFICE- Non-Fibrous 131401754-0023 WALL TILE HOrrtOgeneOUS GROUT r Analyst(s) F1evel Lam(19) Steve Grise,Laboratory Manager Sean Ryan(17) or other approved signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravianetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy,precision and uncertainty data available upon request.Unless requested by the chant,building materials manufactured with multiple layers(i.e.linoleum,wallboard,etc.)are reported as a single sample.Reporting limit is 1% Samples analyzed by EMSL Analytical,Inc.Woburn,MA NVLAP Lab Code 101147-0,CT PH-0315,MA AA0001 B8,RI AAL-10M and V r AL357102 Initial report from 05/16/2014 14:15:38 Test Report PLM-7.28.9 Printed:5/16/2014 2:15:38 PM 3 EMSL Analytical, Inc. EMSL Order: 131401754 7 Constitution Way,Suite 107,Woburn,MA 01801 CUstomerlD: GECL78 Phone/Fax: (781)933-8411/(781)933-8412 CustomerPO: httD://www.EMSL.com bostonlabOemsl.com ProjectlD: Attn: Adam Lesko Phone: (413)341-3418 Green Environmental Consulting, LLC Fax: (413)341-3419 180 Pleasant St Received: 05/12/14 8:30 AM 3rd Floor, Suite 7 Analysis Date: 5116/2014 Collected: Easthampton, MA 01027 Pr 'ect: 00912/CDH-West Win Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Non-Asbestos Asbesto Sample Description Appearance % Fibrous % Non-Fibrous %TVpe 00912-34B BACK STAIRS- Tan 5% Cellulose 75% Non-fibrous(other) 20% Chrysotile LINOLEUM L2 Fibrous 131401754-0009 HOnlOgenet)US 00912-35A BACK STAIRS- Yellow 100% Non-fibrous(other) None Detected LINOLEUM L2 Non-Fibrous 131401754-0010 MASTIC Homogeneous 00912-35B BACK STAIRS- Yellow 100°/6 Non-fibrous(other) None Detected LINOLEUM L2 Non-Fibrous 131401754-0011 MASTIC HOnlOgeneOUS 00912-36A SMALL REHAB Gray 40% Cellulose 20% Non-fibrous(other) None Detected 131401754-W12 HALL-2X2 Fibrous 40% Min.Wool CEILING TILE Homogeneous 00912-36B MAIN REHAB Tan 40% Cellulose 20% Non-fibrous(other) None Detected 131401754-W13 HALL-2X2 Fibrous 40% Min.Wool CEILING TILE Homogeneous 00912-37A VENT ABOVE Tan 82% Non-fibrous(other) 18% Chrysotile CEILING-VENT Non-Fibrous 131401754.0014 SEALANT Homogeneous 00912-37B VENT ABOVE Brown 82% Non-fibrous(other) 186/6 Chrysotile CEILING-VENT Non-Fibrous 131401754-0015 SEALANT Homogeneous 00912-38A MAIN REHAB Brown 3% Cellulose 97% Non-fibrous(other) None Detected HALL-COVE Non-Fibrous 131401754-0016 BASE/SIDE RUG Homogeneous ADHESIVE Analyst(s) Flevel Lam(19) Steve Grise,Laboratory Manager Sean Ryan(17) or other approved signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP.NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravanetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy,precision and uncertainty data available upon request.Unless requested by the chant building materials manufactured with multiple layers(i.e.linoleum,wallboard,etc.)are reported as a single sample.Reporting limit is 1% Samples analyzed by EMSL Analytical,Inc.Woburn,MA NVLAP Lab Code 101147-0,CT PH-0315,MA AA000188,RI AAL-107T3 and VT AL357102 Initial report from 05/16/2014 14:15:38 Test Report PLM-7.28.9 Printed:5/16/2014 2:15:38 PM 2 EMSL Analytical, Inc. EMSL Order: 131401754 7 Constitution Way,Suits 107,Woburn,MA 01801 CUStomerlD: GECL78 Phone/Fax: (781)933-84111(781)933-8412 CustomerPO: htto://www.EMSL.com bostonlab(&emsl.com ProjectlD: Attn: Adam Lesko Phone: (413)341-3418 Green Environmental Consulting, LLC Fax: (413)341-3419 180 Pleasant St Received: 05/12/14 8:30 AM 3rd Floor, Suite 7 Analysis Date: 5/16/2014 Collected: Easthampton, MA 01027 Project: 00912/CDH-West Win Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Non-Asbestos Asbest Sample Description Appearance % Fibrous % Non-Fibrous % TVDe 00912-05D REHAB WAITING Gray 100% Non-fibrous(other) None Detected AREA-GREY Non-Fibrous 131401754-"l FIRESTOP Homogeneous 00912-05E TREATMENT Gray 2% Cellulose 98% Non-fibrous(other) None Detected ROOM 7-GREY Non-Fibrous 131401754-OW2 FIRESTOP Homogeneous 00912-05F MAIN REHAB Gray 100% Non-fibrous(other) None Detected HALL-GREY Non-Fibrous 131401754-0003 FIRESTOP Homogeneous 00912-32A BACK STAIRS- Gray 100% Non-fibrous(other) None Detected 12"BLUE FLOOR Non-Fibrous 131401754-0004 TILE Homogeneous 00912-32B BACKSTAIRS- Gray 100% Non-fibrous(other) None Detected 12"BLUE FLOOR Non-Fibrous 131401754-0005 TILE Homogeneous 00912-33A BACK STAIRS- Yellow 100% Non-fibrous(other) None Detected 12"BLUE FLOOR Non-Fibrous 131401754-0006 TILE MASTIC Homogeneous 00912-33B BACK STAIRS- Yellow 100% Non-fibrous(other) None Detected 12"BLUE FLOOR Non-Fibrous 131401 754-000 7 TILE MASTIC HOf110gene0US 00912-34A BACK STAIRS- Gray 5% Cellulose 80% Non-fibrous(other) 15% Chrysotile LINOLEUM L2 Fibrous 131401754-0008 Homogeneous r A "— Analyst(s) Fievel Lam(19) Steve Grise,Laboratory Manager Sean Ryan(17) or other approved signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NISI or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravirnetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy,precision and uncertainty data available upon request.Unless requested by the client,building materials manufactured with multiple layers(i.e.linoleum,wallboard,etc.)are reported as a single sample.Reporting limit is 1% Samples analyzed by EMSL Analytical,Inc.Woburn,MA NVLAP Lab Code 101147-0,CT PH-0315,MA AA0001$8,RI AAL-107T3 and VT AL357102 Initial report from 05/16/2014 14:15:38 Test Report PLM-7.28.9 Printed:5/16/2014 2:15:38 PM 1 Limited Asbestos Inspection Coo/y Dickinson Hospital dancer Care Reno-ation (Ist Floor OPD Building) Conclusions/Recommendations Asbestos-containing materials (ACM's)were identified during GEC's inspection. Identified ACM's should be should be removed, handled, and disposed of properly, in accordance with applicable state and federal regulations prior to any renovation activity that may disturb them. Any suspect asbestos-containing material that is discovered during building renovation/demolition that is not included in this report should be assumed to contain asbestos until further bulk sampling and analysis is performed. If you have any questions regarding this survey or the sampling and/or analytical techniques employed, please contact us at (413) 341-3418. Sincerely, Green Environmental Consulting, LLC A Adam Lesko President Page 4 of 4 Limited Asbestos Inspection Cooley Dickinson Hospital-Cancer Care Renovation (1st Floor ODD Buildino) Limitations This report is intended for the sole use of Diversified Project Management. This report is not intended to serve as a bidding document nor as a project specification and actual site conditions and quantities should be field-verified. The scope of services performed in execution of this evaluation may not be appropriate to satisfy the needs of other users,and use or re-use of this document,the findings, conclusions, or recommendations herein is at the risk of said user. Although a reasonable attempt has been made to locate suspect asbestos-containing materials (ACM's) in the areas identified,the inspection techniques used are inherently limited in the sense that only full demolition procedures will reveal all building materials of a structure and,therefore, all areas of potential ACM. Exploratory demolition was not performed and potential hidden asbestos may be present behind walls,ceilings, floors and other solid enclosures. Caution should be used during renovation/demolition activities. GEC's inspection did not include the following areas: • Concealed areas (interior of walls) • Electrical systems and/or components were not included in GEC's survey due to the safety issues inherent with sampling such systems • Exterior of the building including windows and roof The Massachusetts Department of Environmental Protection (DEP), as well as the U.S. Environmental Protection Agency (EPA)currently recognize Polarized Light Microscopy (PLM) analysis as an acceptable analytical method for determining the Asbestos content in non-friable, organically bound (NOB) materials. However, comparative studies between PLM analysis and Transmission Electron Microscopy (TEM)analysis have shown that PLM analysis may yield false negative analytical results for NOB's such as floor tiles. GEC recommends that, prior to demolition activities, one sample from each homogeneous area of mastic and other non-friable organically bound (NOB) materials that originally tested negative by PLM undergo confirmatory analysis by TEM, utilizing ELAP-198.4 TEM Method for Identifying and Quantifying Asbestos in NOB bulk samples. Page 3 of 4 Limited Asbestos Inspection �szey Dickinson Hosoital-Cancer are Renovation (1st Floor OPD Building) The following materials were determined to be asbestos-containing materials (ACM's): ASBESTOS-CONTAINING MATERIALS ESTI l• A i ouANTITY NUMBER(S) Linoleum Back Stairway 100 Square 00912-34A&34B 2nd Layer Feet Brown Duct Throughout Renovation Unknown 00912-37A&37B Above Suspended Sealant Area Ceiling Small Grey Block Hall by Elevators 220 Square 00912-43A&43B Linoleum Feet The following materials were sampled and determined not to be asbestos-containing materials (less than one-percent asbestos): NOWASBESTOS MATERIALS LOCATION REFERENCE SAMPLE NUMBER(S) Grey Fire stop Throughout Renovation Area (interior of 00912-05D,05E &05F wall cavities) 12"Blue Floor Tile and Back Stairway 00912-32A,32B,33A& associated Mastic 33B Linoleum Mastic Back Stairway(associated with 2nd layer 00912-35A&35B Linoleum) 2'x2'Ceiling Tile Small Rehab Hall 00912-36A&36B Cove Base Adhesive Throughout Renovation Area (associated 00912-38A& 38B with both vinyl and carpet-type cove moldings) Tan Cove Base Adhesive Throughout Renovation Area 00912-39A&39B Green Carpet Adhesive Throughout Renovation Area 00912-40A&40B Wall Tile Grout Large Rehab Office 00912-41A&41B Skim Coat Over Fire Stop Throughout Renovation Area 00912-42A, 42B&42C Small Grey Block Linoleum Hall by Elevators 00912-44A&44B Mastic Sheetrock Throughout Renovation Area 00912-45A&45B Joint Compound Throughout Renovation Area 00912-46A,46B,46C& 46D Page 2 of 4 Green Environmental Consult 'gjlI LC 180 Pleasant Street U t 3rd Floor- Suite 7 NOV 6 2014 'i( F� tel/fax 413-341-3418 Easthampton, MA 01027 ��ectrrc. _.._., ""� www.GecEnviro.com , June 6, 2014 Gary Brallier Senior Project Manager Diversified Project Management 111 Founders Plaza, Suite 1404 East Hartford, CT 06108 RE: Limited Asbestos Materials Inspection Cooley Dickinson Hospital Cancer Care Renovation (1st Floor-OPD Building) Northampton, MA Dear Mr. Brallier: At your request,Green Environmental Consulting, LLC (GEC) performed a limited asbestos inspection of areas scheduled for renovation at Cooley Dickinson Hospital located at 30 Locust Street in Northampton, MA. GEC's inspection was limited to scheduled renovation areas in the First Floor OPD Building as identified by Diversified Project Management. Fieldwork associated with the project was performed on May 6-9, 2014 by Massachusetts-licensed Asbestos Inspector, Brian Renaud (License# A1900482). Asbestos Sampling/Results Thirty-six(36) samples of suspect asbestos-containing materials(ACM's)were collected and submitted to an accredited laboratory for analysis using Polarized Light Microscopy with Dispersion Staining (PLM/ DS). Materials found to contain greater than one percent asbestos are considered to be asbestos- containing materials (ACM's). Refer to Attachment No.1 for laboratory results, including detailed descriptions of sampling locations, as well as chain-of custody records for samples collected. Page 1 of 4