Loading...
16B-031 (2) solar - - -- -- - - Sing-l-e Phase Inverters for worth America 0 SE6000A US SE760OA-US SE10000A-US SSE1 400A US T --_ SE3000A-US rSE380OA-US 1 SESOOOA US SE6000A-US.I SE760OA US SE10000A-US, SE1140OA US. OUTPUT -- -- SolarEdge Single Phase Inverters . 1000 @zDBV 1 Nominal AC Power Output 3000 3800 5000 6000 7600 1 11400 VA 10000 @240V I 5400 @ 208V 10800 @ 208V For North America Max.AC Power Output 3300 4150 5450 @240V 6000 8350 @240V 12000 VA 10950 AC Output Voltage Min.-Nom.-Max.* ,. SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ A AC C Z9va` Output Output Voltage Min.-Nom.-Max.* ✓ i ✓ ✓ ✓ ✓ ✓ �/ z11-24o-z64Vac SE7600A-US/SE10000A-US/ SE11400A-US AC Frequency Min.-Nom.-Max.* 59.3-60-60.5(with HI country setting 57-60 60:5) Hz `+- fi'-"f` Max.Continuous Output Current 12.5 16 21 @ 240V 25 32 42 @ 240V 47.5- A a GFDI .. - 1 ... A - a Utility Monitoring,Islanding Yes I Protection,Country Configurable •rte Thresholds INPUT 3750 4750 6250 7500 9500 4� Recommended Max.DC Power** 12 ,. - - 400 ( 14250 W Walt.. i (STC) ,. �,...._. .. ... i�. ._ ..... Transformer-less,Ungrounded Yes .. x .' Ja1�a►o Max.Input Voltage. ... ... 500 .. -... .. Vdc . �-- ( l 325 @ 208V/350 @ 240V '. Nom.,DC Input Voltage Vdc 16.5 @ 208V 1 33 @ 208V P�• Max.Input Current*** 9.5 13 18 23 34.5 Adc 15 5 @ 240V i ! 30.5 @ 240V I , Max.Input Short Circuit Current i 30 600ksa Sensiti v 45 Adc Revers V. ... ... _.. e-Polant Protection � Yes Maximum Inverter Efficiency 1 .. . 97.7 98.2 . 98.3 973 9 75 ._.98 Ground-Fault Isolation Detection - g7.5 @ 208V - �Ity @ i 978.5 K,& - CEC Weighted Efficient 97.5 98 98 @ 240V 97 2240 97.5 @ 240V I ' g Y l 1 .. .. ... _ <4 .. W .. Nighttime Power Consumption -.<2.5 - -.. _- -- -- Spportl dN ommEAT ahon InteES RS485 RS232,Ethernet,ZlgBee(optional) _ - x "r � :. Revenue Grade Data AN51 C12.1 i- --_- —Optional x �r STANDARD A RD COM.P LIANCE ---__ --- .- UL.1741 UL16998 UL1998,CSA 22.2 Safe ..IEEE1547 Grid Connection Standards _ .. zS, Emissions FCC part15 class B _.- ---. 2 - INSTALLATION SPECIFICATIONS — ) — .. W„. output conduit size/AWG range 3/4'minimum/24-6 AWG 3/4”minimum/8-3 AWG DC input conduit size/p of strings/ .,. 3/4"minimum/1-2 strings/24-6 AWG 3/4"minimum/1-2 strings/14-6 AWG AWG range _ Dimensions with AC/DC Safety 30.5 x 12.5 x 7/ 30.5 x 12.5 x 7.5/ _ m ll / 30.5 x 12.5 x 10.5/77S x 315 x 260 mm Switch(HxWxD) 775 x 315 x 172 775 x.315 x 191 .... Weight with AC/DC Safety Switch 511/23.2. ( 54.7/24.7 88.4/40.1 Coolin Natural Convection ns(user replaceable) 1 „,. Fa B ....... - .... ..._. .... ...... _ --.. .. .. . . _.. <25 1 _.<50 I deA... Noise1.... .._. _. The best choice 1©I*SOIarEdge enabled systems Mm:Max.Operating Temperature 13 to+140/ 25[o+60(CAN version-*** to+60) -F/'C m Integrated arc fault protection(Type 1)for NEC 2011 690.11 compliance Range_ . .. . . Superior efficiency(98%) Fit rotection Rating NEMA 3R _ _ _. _ _ For other regional .thrills pl t ct 5 l arEdge support. Small,lightweight and eas to install on provided bracket Limited t 175%f locations h theyearly average high temperature bo 77F/25C and to 135%for locations where it is below 77'F/25'C. y (� For detailed information refer to Intto.//www. fared /file 7odfs/'n aer do oversaina guide odf Built-in module-level monitoring :Ahigher current source may be used;the inverter will limit its input current to the valoes stated. g CAN P/Ns are eligible for the Ontario FIT and micmFiT(microFiT exc.SE31400A-US-CAN). — Internet connection through Ethernet or Wireless — Outdoor and indoor installation — Fixed voltage inverter,DC/AC conversion only — Pre-assembled AC/DC Safety Switch for faster installation — Optional—revenue grade data,ANSI C12.1 StXISF�c USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.us • solar - . = solar " @ • Sol arEdge Power Optimizer Module Add-On for North America P300 / P350 / P400 SolarEdge Power Optimizer P300 --_. P350 P400 Module Add-On For North America ffor 60-cell PV I (for 72-cell PV (for 98-cell PV modules) modules) modules) P300 / P350 / P400 INPUT Rated Input DC Powerf') 300 350 400 ! W Absolute Maximum Input Voltage(V c temperature) 48 60 80 Vdc MPPT Operating Range 8 48 8-60 8-80 Vdc o at lowest t t ty -"taxa�g-y3xk6'� ^, 'T+ k�° • Maximum Short Circuit Current(ISC) 10 Ad, Maximum DC Input Curren[ 12.5 Adc �'� Maximum Efficiency. 99.5 % Weighted Efficiency 98.8 % -.. -.OPERATING INVERTER) Overvoltage Category II , OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPER G INVE ER) Maximum Output Current 15 Adc Maximum Output Voltage 60 Vdc ` `gi Y, , '' � �:y • OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) ^'- t s, Safety Output Voltage per Power Optimaer 1 Vdc ' `et STANDARD COMPLIANCE .f >.� _.- T.t ' EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class It safety),UL3741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions(W x L x H) 141x212 x40.5/S.SSx8.34x 1.59 mm/in Weight(including cables) 950/2.1 .� gr/Ib Input Connector MC4/Amphenol/Tyco Output Wire Type/Connector Double Insulated;Amphenol Output Wire Length j 0.95/3.0 -1.2/3.9 m/ft Operating Temperature Range -40-+85/-40-+185 '�, *C/'F Protection Rating IP65/NEMA4 Relative Humidity 0-100 % eareas paver o1 —dull or rpm«sx 1­1m«:a<aao.ae. ., , PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE THREE PHASE INVERTER 208V 480V PV Power optimization at the module-level Minimum String Length(Power Optimizers) 8 10 18 • Up to 25%more energy - Maximum String Length(Power Optimizers) 25 25 ! 50 Superior efficiency(99.5%) Maximum Power per String 5250 6000 12750 W Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading Parallel Strings of Different Lengths or Orientations Yes Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module-level monitoring Module-level voltage shutdown for installer and firefighter safety u'n GFHMAN7 - ITAIV FrANrl APAN - CMNA sRAFI - Au,1RAIIA www.solaredge.uS Qe CS6P-235/240/245/250/255PX �e��t�►i7eQes�ga akc�to,,gh \r CanadianSolar Black-framed Electrical Data Bte s-rc cs6P-235P cssP-zaoP cs6P-245P CS6P-250PXCS6P-255PX Temperature Characteristics Nominal Maximum Power(Pmax) 235W 240W 245W 250W 255W Optimum Operating Voltage(Vmp) 29.8V 29.9V 30.OV 30.1V 30.2V Pmax -0.43%/C NewEdge Optimum Operating Current(Imp) 7.90A 8.03A 8.17A 8.30A 8.43A Temperature efficient Voc -0.34%/°C Open Circuit Voltage(Voc) 36.9V 37.OV 37.1V 37.2V 37AV Ise 0.065%/°C Black-framed Short Circuit Current(Ise) 8.46A 8.59A 8.74A 8.87A 9.00A Normal Operating Cell Temperature 45±2°C • Module Efficiency 14.61% 14.92% 15.23% 15.54% 15.85% Operating Temperature -40°C-+85°C Performance at Low Irradiance Maximum System Voltage 1000V IEC 1600V(UL) Industry leading performance at low irradiation Maximum Series Fuse Rating 15A environment,+95.5%module efficiency from an Application Classification ClassA irradiance of 1000w/m'to 200w/m' Power Tolerance 0-+5W (AM 1.5,25"C) Next Generation Solar Module Under Standard Test Conditions(STC)of irradiance of 1000W/m',spectrum AM 1.5 and cell temperature of 25'C NewEdge,the next generation module designed for multiple -- - - --- - - 6- Engineering Drawings NOCT CS6P-235P CS6P-240P CS6P-245P CS6P-250PX CS6P-255PX types of mounting systems,offers customers the added Nominal Maximum Power(Pmax) 170W 174W 178W 181W 185W value Of minimal system costs,aesthetic seamless Optimum Operating Voltage(Vmp) 27.2V 27.3V 27AV 27.5V 27.5V j appearance,auto groundingand theft resistance. Optimum Operating Current(Imp) 6.27A 6.38A 6.49A 6.60A 6.71A Open Circuit Voltage(Voc) 33.9V 34.OV 34.1V 34.2V 34AV The black-framed CS6P-PX is a robust 60 cell solar module Short Circuit Current(Ise) 6.86A 6.96A 7.08A 7.19A 7.29A incorporating the groundbreaking Zep compatible frame. under Normal operating cell Temperature,bradlance of 8OO Winn',spect-AM 1.5,ambient temperature 20C, The specially designed frame allows for rail-free fast wind speed 1 m/s installation with the industry's most reliable grounding Mechanical Data system.The module uses high efficiency poly-crystalline Cell Type Poly-crystalline 156 x 156mm,2 or 3 Busbars 1111 11 11 1 IF_ Key Features silicon cells laminated with a white back sheet and framed Cell Arrangement 60(6 x 10) with black anodized aluminum.The black-framed CS6P-PX Dimensions 1638 x 982 x 40mm(64.5 x 38.7 x 1.57in) • Quick and easy to install - dramatically is the perfect choice for customers who are looking for a high Weight 20.5kg(45.2 Ibs) reduces installation time quality aesthetic module with lowest system cost. Front cover 3.2mm Tempered glass Frame Material Anodized aluminium alloy III I III Hil I • Lower system costs - can cut rooftop Best Quality .1-Box IP65,3 diodes installation costs in half Cable 4mm°(IEC)112AWG(UL),1000mm • 235 quality control points in module production connectors MC4 or MC4 Comparable • Aesthetic seamless appearance - low profile • EL screening to eliminate product defects Standard Packaging(Modules per Pallet) 24pcs with auto leveling and alignment Current binning to improve system performance Module Pieces per container(40 ft.Container) 672pcs(40'HO) • Accredited Salt mist resistant - _ t --- -_ -• Built-in hyper-bonded grounding system - if it's j -V Curves(CS6P-255PX) mounted,it's grounded Best Warranty Insurance • Theft resistant hardware • 25 years worldwide coverage • 100%warranty term coverage seeOonA-A • Ultra-low parts count - 3 parts for the mounting Providing third party bankruptcy rights 35.0 and grounding system Non-cancellable I • Industry first comprehensive warranty insurance by Immediate coverage o AM Best rated leading insurance companies in the Insured by 3 world top insurance companies o >> world Comprehensive Certificates • Industry leading plus only power tolerance:0--+5W - - 115 • IEC 61215,IEC 61730, IEC61701 ED2,UL1703, <a • Backward compatibility with all standard rooftop and CEC Listed,CE and MCS ground mounting systems • IS09001:2008:Quality Management System • ISO/TS 16949:2009:The automotive quality 'Specifications included in this dalasheet are subject to change without prior notice. • Backed By Our New 10/25 Linear Power Warranty management system Plus our added 25 year insurance coverage • IS014001:2004:Standards for Environmental About Canadian Solar management system Canadian Solar Inc. is one of the world's largest solar Canadian Solar was founded in Canada in 2001 and was 10s�x q QC080000 HSPM:The Certification for companies. As a leading vertically-integrated successfully listed on NASDAQ Exchange (symbol: CSIQ) in dded Value F manufacturer of ingots,wafers,cells,solar modules and November 2006. Canadian Solar has module manufacturing Sox From Warranty Hazardous Substances Regulations solar systems, Canadian Solar delivers solar power capacity of 2.05GW and cell manufacturing capacity of 1.3GW. • OHSAS 18001:2007 International standards for products of uncompromising quality to worldwide 80% occupational health and safety customers. Canadian Solar's world class team of 0% REACH Compliance professionals works closely with our customers to 5 10 15 20 2.1 P provide them with solutions for all their solar needs. Headquarters 1545 Speecj�ale Ontario Guelph I Tel +1 519 837 1881 10 year product warranty on materials and workmanship O `_? RI-X E` G SGS--c- yF"' Fax 1 519 837 2550 •25 year linear power output warranty www.canadiansolar.com EN-Rev 10.17 Copynght c 2012 Canadian Solar Inc. SolarCity SleekMountT"" - Comp SolarCity SleekMountT"" - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed -*\ Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules aesthetics while minimizing roof disruption and .Interlock and grounding devices in system UL ;y Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and listed to UL 2703 Fastener Size Per NDS Section 1.1.3.2 mounting clamps, combined with the addition of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 Seal pilot hole with roofing sealant to a more visually appealing system.SleekMount as"Grounding and Bonding System" . Insert Comp Mount flashing under upper utilizes Zep CompatibleTM modules with •Ground Zep UL and ETL listed to UL 467 as layer of shingle strengthened frames that attach directly to grounding device Place Comp Mount centered Zep Solar standoffs, effectively eliminating the need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition .Anodized components for corrosion resistance Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this with sealing washer. system, allowing for minimal roof disturbance. •Applicable for vent spanning functions s Secure Leveling Foot to the Comp Mount using machine Screw Place module Components ` 5/16"Machine Screw `' t� Leveling Foot �' h Lag Screw Comp Mount Comp Mount Flashing 0 u F,0"MPA,,P W LISTED SolarCity Januar y 2013 EA SolarCity, Januar y 2013 WARNING:PHOTOVOLTAIC POWER SOURCE Code: WARN i N G Code:Location: Per Label WARNING Per ..- NEC 690.31.G.3 ELECTRIC SHOCK HAZARD 90 ELECTRIC SHOCK HAZARD •. DO NOT TOUCH TERMINALS THE DC CONDUCTORS OF THIS Label • • TERMINALS ON BOTH LINE AND PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN PHOTOVOLTAIC DC LOADN TH OPEN POSITIONIZED MAY BEOENDERG ZED INVERTERIS DISCONNECT Per "e NEC .•0 Label Location: WARNING MAXIMUM POWER-- D Code: POINT CURRENT(Imp) A INVERTER OUTPUT 690.64.B.7 CONNECTION MAXIMUM POWER- V NEC 690.53 DO NOT RELOCATE POINT VOLTAGE(Vmp) THIS OVERCURRENT MAXIMUM SYSTEM V DEVICE VOLTAGE(Voc) SHORT-CIRCUIT A CURRENT(Isc) Label • • PHOTOVOLTAIC POINT OF (POI) Label INTERCONNECTION Per Code: WARNING WARNING: ELECTRIC SHOCK •. •. , ' HAZARD.DO NOT TOUCH Per Code: TERMINALS.TERMINALS ON ELECTRICAL SHOCK HAZARD 690.17(4) MAY BE ENERGIZED IN THE OPEN TERMINALS ON BOTH LINE AND POSITION. FOR SERVICE LOAD SIDES MAY BE ENERGIZED DE-ENERGIZE BOTH SOURCE IN THE OPEN POSITION AND MAIN BREAKER. DC VOLTAGE IS PV POWER SOURCE ALWAYS PRESENT WHEN MAXIMUM AC _ A SOLAR MODULES ARE OPERATING CURRENT EXPOSED TO SUNLIGHT MAXIMUPA AC OPERATING VOLTAGE V Label • • WARNING Label Location: ELECTRIC SHOCK HAZARD Code: CAUTION D P' NEC IFAGROUND FAULT IS INDICATED •.0 PHOTOVOLTAIC SYSTEM Code:_ NORMALLY GROUNDED CIRCUIT IS BACKFED 690.64.B.4 CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED Label • • Label • - CAUTION '_• Disconnect PHOTOVOLTAIC AC DUAL POWER SOURCE Code: DISCONNECT Per Code:� ••e PHO OVOLTAOIC SYSTEM ''' ', ' I Conduit •• • . Distribution DC Disconnect Conduit(IC): Interior Run Label Location: (INV): Inverter With Integrated DC MAXIMUM AC -• •.. Center OPERATING CURRENT A Code:AC V •« -• Point of • • OPERATING VOLTAGE 1 /7 1' 1 1 71 • 1 1 /• •ul• I•Itnn■ I •i• •uott •tt«■ 1 r• 1 1 7' 1 1 • r Label ' / ' unnnul«un'.t■•uuo«nn'«urnn 1 1 IllIt III1:/ 11 1111'NII.1'.111•���Itlll t�•II III111! CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 35 Fern St AC DISCONNECT r-----------, INVERTER AND `----------- DC DISCONNECT I I I L--------------------- AC DISCONNECT UTILITY SERVICE r------------------------- —� SOLAR PHOTOVOLTAIC ARRAY(S' PHOTOVOLTAIC BACK—FED CIRCUIT BREAKER IN FAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 24OV CONFlDENTIAL— THE INFORMATION HEREIN JOB NUMBER PREMISE OWNER: DESCRIPTION: DESIGN: JB-010401 00 , CONTAINED SHALL NOT CE USED FOR THE KELLEY, RICHARD G KELLEY RESIDENCE William Avery SolarCity. BENEFlT OF ANYONE EXCEPT SOLARCI7Y INC., MOUNTING SYSTEM: ���� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type c 35 FERN ST 7.14 KW PV ARRAY or . PART TO TION,OTHERS E OUTSIDE THE RECIPIENTS MODULES NORTHAMPTON M A 0106 2 ORGANIZATION, EXCEPT IN CONNECTION WITH r THE SALE AND USE OF THE RESPECTIVE (28) CANADIAN SOLAR # CS6P-255PX 1 24 St. Morten Drive,Building 2,Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: Marlborough,MA 01752 PERMISSION of soLARarr INC. INVERTER: T.. (650)638-1028 F: (650)638-1029 SOLAREDGE SE6000A—US—ZB—U 413-588-4858 SITE PLAN PLACARD PV 7 9/4/2014 (88)— T (765—CITY orn GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #6 GEC TO TWO (N) GROUND Panel Number: Inv 1: DC Ungrounded INV 1 -(1)SOLAREDGE ##SE6000A-US-ZB-U LABEL: A -(28)CANADIAN SOLAR CS6P-255PX GEN #168572 RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:98355605 Tie-In: Supply Side Connection Inverter; 6000W, 240V, 97.5% w/Unifed Disco and ZB, AFCI PV Module; 255W,'234.3W PTC, Black Frame, MC4, ZEP Enabled ELEC 1136 MR Underground Service Entrance INV 2 Voc: 37.4 Vpmax: 30.2 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 125A MAIN SERVICE PANEL E 125A/2P MAIN CIRCUIT BREAKER CU Inverter 1 CUTLER-HAMMER SOLARGUARD (E) WIRING Disconnect CUTLER-HAMMER METER SOLAREDGE 125A/2P 5 Disconnect 4 B 35A C SE6000A-US-ZB-U D I SolarCity L1 24.V 1 2 A DC+ s Lz A _ N 3 DC 2 Stnng(s)Of 14 On MP1 (E) LOADS GND _ _-__ GND _ -- GND --- ------------- - EGCI T DC+ DG GEC DG I r---J Ems--------------------------- -- ,---- ---EGC -- ---------- -- i I N I I _J 4,C_CGEC 1 I I I I I - GEC-r-1 TO 120/240V SINGLE PHASE I I UTILITY SERVICE I I i i I I I I 1 PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP POI (2)Ground Rod; 5/8'x 8',Capper B (1)CUTLER-HAMMER /DG222NRB ^ A (i)S2x2 S 4 STRING JUNCTION BOX DC Disconnect; 60A, 24OVoc,Fusible, NEMA 3R /y 2x2 STRGS, UNFUSED, GROUNDED -(2)IL.SCO/ n 4/o-/6 Insulation Piercing Connector; Main 4/0-4, Top 6-14 -(1)CUTLER-HAMMER DG100N8 `/ (28)SOLAREDGE�300-2NA4AZS C Ground/leutrd Krt; 60-100A, General Duty(DG) P V Power9ox fenizer, 300W, H4, DC to DC, ZEP (1)CUTLER-HAMMER/DG222URB -(I CUTLER-HAMMER DS16FK Disconnect; 60A, 24OVoc, Non-Fusible,NEMA 3R Class R Fuse Kit nd (1)AWG 16, Solid Bare Copper -(1)CUTLER- AMMER DG10ONB -(2)FERRAZ SHAWMUT/TR35R PV BACKFEED OCP Ground/Neutral Kit; 60-100A, General Duty(DG) Fuse; 35A. 25OV, Class RK5 -(1)Ground Rod; 5/8'x 8',Copper SC SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE D SolarGuard Monitoring System i(N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. .ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF E ELECTRODE (1�WG #6 THWN-2,Black -- -- -- ---_-�(1�AWG/8, THWN-2. Block--- ---- -- - ---�1 AWG/6, THNM-2, Black -------Voc* -500 VDC Isc =30 ADC --- -- (2)AWG/10, PV WIRE Black Voc* =500 VDC Isc 15 ADC O (1)AWG#6, THWN-2 Red (A (1)AWG#8, THWN-2, Red O (1)AWG/6, hlyy11_2 Red Vmp =350 VDC Imp=20.14 ADC O (1)AWG�, Solid Bare Copper EGC Vmp =350 VDC Imp=10.07 ADC ��LL(1)AWG/6, THWM-2, White NEUTRAL Vmp =240 VAC ImP=25 AAC LPL(1)AWG/10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=25 AAC (1)AWG/10, M"7?..Green EGC -(1)Conduit.Kit.3/4�.EMT . . . . . . . LLLJJJ -(1)AWG ,,Solid Bare,Copper, C£C, .-(1)Conduit_Kit;.3/4'.EMT. . . . . . . , , . . .-(1)AWG/6,.TFiWM-2,.Green . , EGC/GEC.-(1)Conduit.Kit:.3/4'.ENT (Y)AW6 0, PV WIRE,Black Voc* =500 VDC Isc =15 ADC OM:(1)AWG 06, Solid Bare Copper EGC Vmp =350 VDC Imp=10.07 ADC PREYSE O O: DESCRIPTION: DESIGN CONFlDNED S - THE INFORMATION HEREIN J06►A1118ER JB-010401 00 r William Avery �,!?SolarCity. CONTAINED SHALL NOT BE USED FOR THE KELLEY RICHARD G KELLEY RESIDENCE BENEFIT OF ANYONE EXCEPT SO.ARCITY INC., MOUNTING SYSTEM A NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 35 FERN ST 7.14 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS NORTHAMPTON MA 01062 ORGAMZAl10N, EXCEPT IN CONNECTION WITH MODULES r 24 St.Martin Drivel,Buildng 2 Unit 11 THE SALE AND USE OF THE RESPECTIVE 28 CANADIAN SOLAR CS6P-255PX µ pph Mar8-1028 MA 50) SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER. PAGE NAAE L (650)638-1028 F: (650)638-1029 PERMISSION of SOLARCITY INC SLA 413-588-4858 THREE LINE DIAGRAM PV 6 9/4/2014 (888)-sa-CITY(765-2489) www.salarciiy.cam SOLAREDGE SE6000A-US-ZB-U UPLIFT CALCULATIONS SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. CONFIDENTIAL— THE INFORMATION HEREIN im NUMBER: J B-010401 0 0 PREMISE OWNER: DESORIPTW. DESIGN: CONTAINED SHALL NOT BE USED FOR THE KELLEY RICHARD G KELLEY RESIDENCE William Aver • NOR SHALL ITNBEN DISCLOSED ININN WHOA OR IN MOUNTING SYSTEM:u 35 FERN ST y IwAsolarCity. PART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type c 7.14 KW PV ARRAY ►�� ORGANIZATION, EXCEPT IN CONNECTION WITH MODULM. NORTHAMPTON, MA 01062 THE SALE AND USE OF THE RESPECTIVE (28) CANADIAN SOLAR # CS6P-255PX 1 24 St.Matt Drive, Building 2,Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV.. DATE: Marlborough,MA 01752 PERMissloN of soLARaTY INC. 413—588—4858 P V 5 9/4/2014 (BB1ij SOLO)CITY(765-2489) www sa�larcRyoom SOLAREDGE sESOOOA—us—ze—u UPLIFT CALCULATIONS 1 1 r)PF;w n. S 1 I+� �� 2'-2„ '-4„ STAMPED & SIGNED (E) LBW FOR STRUCTURAL ONLY A SIDE VIEW OF MP1 NTS MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" STAGGERED PORTRAIT 48" 20" TOP CHORD 2X4 @ 24" OC ARRAY AZI 176 PITCH 19 STORIES: 1 BOT CHORD 2X4 @24" OC Comp Shingle PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) POLYU EITHANEOSEA ANT. ZEP COMP MOUNT C ZEP FLASHING C (3) (3) INSERT FLASHING. (E) COMP. SHINGLE q:::PKMOUNT. (1) (E) ROOF DECKING V (2) U INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES FINSTALL LEVELING FOOT WITH WITH SEALING WASHER (6) BOLT & WASHERS. (2-1/2" EMBED, MIN) (E) RAFTER STANDOFF CONFlDENTIAL— THE INFORMATION HEREIN pB NUMBER: PREMISE DINER: DESCRIPIM DESPI: `\\� ■ CONTAINED SHALL NOT BE USED FOR THE JB-010401 00 KELLEY, RICHARD G KELLEY RESIDENCE William Avery SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM �►,` NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 35 FERN ST 7.14 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS NORTHAMPTON M A 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St.Martin Drhe, Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE 28 CANADIAN SOLAR # CS6P-255PX SHEET: REV: DATE Marlborough,MA 01752 SOLARg1Y EQUIPMENT, WIIHWT THE WRITTEN ( ) tt PAGE NAME T: (650)636-1028 F: (650)638-1029 PERMISSION Q sMENT, % INC. �R1ER: 413-588-4858 PV 4 9/4/2014 (666)-SOL-CITY(765-2469) ■ww.soiaraRy.Cam SOLAREDGE SE6000A—US—ZB—U STRUCTURAL VIEWS PITCH: 19 ARRAY PITCH:19 MP1 AZIMUTH: 176 ARRAY AZIMUTH: 176 41 '`'�5;;:. MATERIAL: Comp Shingle STORY: 1 Story )4 �� STTillc ,r..�tt.;E c� F STAMPED & SIGNED FOR STRUCTURAL ONLY O © Inv Digitally signed by Andrew White _` 1 AC 1 Date:2014.09.05 14:04:07-04'00' i1 , i I l � D , Irf X11 LEGEND Q (E) UTILITY METER & WARNING LABEL [CB I my INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS © DC DISCONNECT & WARNING LABELS MID AC DISCONNECT & WARNING LABELS Q DC JUNCTION/COMBINER BOX & LABELS DISTRIBUTION PANEL & LABELS Front f Pd Se LC LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER C) STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR -- CONDUIT RUN ON INTERIOR GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED r,_-i It 11 INTERIOR EQUIPMENT IS DASHED L-"J SITE PLAN N Scale: 1/8" = 1' IN E 0 1' 8' 16' S CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-010401 00 PREMISE 01TNER: DESCRIPTION: DESIGN: RICHARD G CONTAINED SHALL NOT E USED FOR THE KELLEY, KELLEY RESIDENCE William Avery �OI�r�'�` , BENEFIT OF ANYONE EXCEPT SOLARCITY INC.. MOUNTING SYSTEM: �.�� y NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 35 FERN ST 7.14 KW PV ARRAY 4, PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES NORTHAMPTON M A 0106 2 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (28) CANADIAN SOLAR # CS6P-255PX 24 St. Martin Drive,Building 2,Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE: Marlborough,MA 01752 PERMISSION SoLARa,Y INC. INVERTER: 413-588-4858 PV 3 9/4/2014 . (650)638-1026 F: (650)636-1029 SOLAREDGE SE6000A—US—ZB—U SITE PLAN ( )-SOL-CITY(765-2489) nwwsolarcityx 44t PROPERTY PLAN N Scale:l" = 20'-0 w E 0 20' 40' S J B-010 401 00 PREP OVER: DEsalPTro� DES . CONFIDENTIAL— THE INFORMATION HEREIN IDB NUI�FR KELLEY, RICHARD G KELLEY RESIDENCE Y ���SDIa���tV CONTAINED SHALL NOT BE USED FOR THE wlliam Aver . 1' NNOR SHALL IT ITNBE ANYONE I MOLE OR MOUNTING m SMM 35 FERN ST 7.14 KW PV ARRAY �ns PART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES NORTHAMPTON, MA 01062 24 St.Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTroE (28) CANADIAN SOLAR # CS6P-255PX REV. DATE Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER- PAGE NAME SHEET: T: (650)638-1028 F: (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE6000A—US—ZB—U 413-588-4858 PROPERTY PLAN PV 2 9/4/2014 (sm)-sot-aw(765-2409) www.ealaraity- ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERIIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. City of Northampton CONIC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING Building Department DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN Plan Review EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. 212 Main Street (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, Northampton, MA 01060 FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET i PV2 PROPERTY PLAN �V,- PV3 SITE PLAN Ell PV4 STRUCTURAL VIEWS LICENSE GENERAL NOTES PV5 UPLIFT CALCULATIONS PV6 THREE LINE DIAGRAM GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION _ Cutsheets Attached ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: AHJ: Northampton REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: National Grid USA (Massachusetts Electric) • AI J[3-01 0401 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER `\�1�SolarCity. CONTAINED SHALL NOT BE USED FOR THE KELLEY, RICHARD G KELLEY RESIDENCE William Avery �,�,l, • BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ��'0� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 35 FERN ST 7.14 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES: NORTHAMPTON, MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St.Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (28) CANADIAN SOLAR # CS6P-255PX PAGE NAME: SHEET: REV: DATE: Marlborough.MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T: (650)636-1028 F. (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE6000A—US—ZB—U 413-588-4858 COVER SHEET PV 1 9/4/2014 (866)-sal—CITY(765-2489) www.Warcity.com CALCULATION OF DESIGN WIND LOADS - MPi Mounting Plane Information Roofing Material Comp Roof PV System Type SolarCity SleekMountTm Spanning Vents No Standoff Attachment Hardware) Qgmg Muni e Roof Slope 190 Rafter Spacing 24"O.C. Framin T Direction Y-Y Rafters Purlin Spacing X-X Purlins Only NA Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only NA Standing Seam Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 90 C ph Section 6.5.6.3 Exposure Category Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h 15 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 6-3 Topographic Factor Krt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh =0.00256(Kz)(Krt)(Kd)(V^2)(I) Equation 6-15 15.0 Psf Wind Pressure Ext. Pressure Coefficient U GC -0.88 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down GC 0.45 Fig.6-116/C/D-14A/B Design Wind Pressure p p=qh(GC) Equation 6-22 Wind Pressure U -13.1 psf Wind Pressure Down 10.0 1W ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 19 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual -221 lbs Uplift Capacity of Standoff T-allow 500 Ibs Standoff Demand Ca aci DCR 44.1% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 64" Max Allowable Cantilever Portrait 20" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 21 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual -245 lbs Uplift Capacity of Standoff T-allow 500 Ibs Standoff Demand Ca aci DCR 49.0% Simpson Strong-Tie Truss: MP1 �J ProjectName: Kelly Component SolutionsTM Date: 9/5/2014 1:39:27 PM Truss Page: 1 oft Version:5.3[Build 361 Span Pitch Qty OHL OHR CANT L CANT R PLYS Spacing WGT/PLY 24-8-0 4/12 1 2-2-0 2-2-0 0-0-0 0-0-0 1 24 in 83 Ills 29-0-0 2-2-0 6-6-14 5-9-2 5-9-2 6-6-14 2-2-0 6-6-14 12-4-0 18-1-2 24-8-0 5x5- 3 12 12 4F ---14 3x4/ 3x4\ 2 4 .4 I� 3x8- — Ji 3x8- 1 5 9 8 7 6 10 1 x4 1 5x8- 1x4 1 0-0-0 0-0-0 6-0-14 5-9-2 5-9-2 6-6-14 6-6-14 12-4-0 18-1-2 24-8-0 Loading General CSI Summary Deflection L/ (loc) Allowed Load (ps0 Bldg Code IBC 2009/ TC: 0.73(1-2) WrtTL: 0,33 in L/883 (7-8) L/180 Roof Snow'(Ps). 30.8 psf lPI 1-20(17 BC: 0.90(8-1) Wo LL: 0,12 to L/999 (6-7) L/240 TCDL: 7 Rep.,Increase Yes Web: (1.85(2-7) Hor.TL: 0.1 in 5 BCLL: 0 D.O.L: 125% Creep Factor Ker=1.5 BCDL In Plate Offsets(Jnt XY.An y (1:4-14,2-1,0.) (2:1-12,3-2,18.) (3:0-0.3-11,0,) (4:1-12,3-2.18.) (5'4-14 2-1,0.) (611-0 3 41 90) (T04),2-8,0) (8:04)3.8,90.) Reaction Summary JT Type Big Canto Big Width Material Rqd Brg Width Max React Ma G.,Uplift Max MWFRS Up1ifl Nk C&C Uplift Max Uplift Ma He- 1 Pin(Wall) 1 3.5 m Steel 2.38 in 1,517lbs - -246 Ibs 634 Ibs 634 Ibs -3916s 5 H Roll(Wall) 1 3.5 in Steel 2.30 in 1,46616s - -277 Ibs 665 Ibs 665 Ibs n lbs Material Summary Bracing Summary 7C SPF#2 2 x 4 TC B acing: Sheathed or Pudins at 2-54),Pudin design by Others. BC SPF#2 2 x 4 BC Bracing Sheathed or Pudius at 5-114),Pudin design by Others. Webs SPF#2 2 x 4 Loads Summary 1)Ibis uuss has been designed for the elf is due to HI psfbottom chord live load plus dead bads. 2)This truss has been designed for the effects of a balanced design snow load(Ps=30.8 psf)and unbalanced design snow loads(4/12,9.2 psf wind,30.8 psf lee.20.4 psf lee oner peak to 8.5 ft)for hips/gables in accordance with ASCE7-05 with the following user defined input.40 psfgmund snow load fty Terrain CacWryC,E posure Caegory Partially Exposed(Ce=1 0),Building Caogary 0(I=101 Thcmnl Condition Cold ientilated(Ct=1.11 Roof Slope Factor(Cs=1.00).DOL=1.15, 3)This truss has been designed for the effects ofwind loads in accordance with ASCE7-05 with the following user defined input 90 r ph noninal.Exposure C,Fully Enclosed. Gzbk(Hip.Building Category B(I=100),h=B=L=15 ft,Egad Zone Truss.Both end webs considered.IDOL=160,CC Zone Width 12.33 R 4)In addilion to the snow loading specified on this dr ing this truss has also been designed fora moflive load(XLL)of20 psf. 5)Miniirum stor W attic loafing in accordance with BC Table 1607.1 has been applied Load Case Dl:Std Dead Load Distributed Loads Menber Location I Loeation 2 Direction Spread Slav Load End Load Trib Width Top Chd -2-24) 12-3-0 Down Pml 3 psf 3 psf 24 in Member Forces Summary Table indicates Harter 1D,rrex CSC npc axial force.(ruax corer force ifdilrerent from ryes axial force) TC 9-1 11.445 56 lbs 2-3 0.656 -2,0061bs 4-5 0.691 -3,16716s 1-2 0730 -3234lbs 34 0617 -2000lbs 5-10 0.412 52Ibs BC 56 0.877 2,939 Ibs (137 Ibs)7-8 0.795 2 997 Ibs (-912 Ibs) 6-7 (1.782 2 939 Ibs 137 Ibs 8-I 0.898 2 9971bs )12 Ibs Webs 2-8 01157 2111bs 3-7 0.188 7671bs (-245 lbs)46 01157 251 Ibs 2-7 0.852 -1.294 Ibs 4-7 0.81) -L232 Ibs Notes: I)When this truss has been chosen for quality assur m ce inspection,the Plate Placeen Me t thod per TPI 1-2002/.43.2 shall be used.Cq=1.17. 2)Listed wind uplift ms0ons based on MWFRS&C&C foaling NOTICE Acopy of this design shall be famished to the erection contractor.The design of this individual truss is based on design criteria and requirencnts supplied by theTmss Manufacturer and tclies upon the accuracy $1mpSOn$[rong-Tle Company and coupleteness ofthe infomotion so forth by the Building Designer A seal on this drawing indicates acceptance ofpmfessional engincering responsibility solely for the truss corponent design shown.ice the cover pays and the"hrponant Infomration&General Notes"page for additional inforrantio n.All connector plates shall be manufactured by Simpson Strung-lie Conpanr.Inc in accordance with ESR-2762.All connector plates arc 20 gaulp.unless the specified plate sin is followed by a"All"which indicates an 18 gain plate.or"S#18",which indicates a high tension 18 gage plate. su —. LOAD ITEMIZATION - MP1 PV System Load PV Module Weight(psf) 2.5 psf Hardware Assembly Weight 0.5 psf PV System Weight 3.0 Psf Roof Dead Load Material Load Roof Category Description MPI Roofing Type Comp Roof ( 1 Layers) 2.5 psf Re-Roof to 1 Layer of Comp? No Underlayment Roofing Paper 0.5 psf Plywood Sheathing Yes 1.5 psf Board Sheathing None Rafter Size and Spacing 2 x 4 @ 24 in. O.C. 0.7 psf Vaulted Ceiling No Miscellaneous Miscellaneous Items 1.3 sf Total Roof Dead Load 7 MPi 7.0 Reduced Roof LL Non-PV Areas Value ASCE 7-05 Roof Live Load Lo 20.0 psf Table 4-1 Member Tributary Area At <_200 sf Roof Slope 4/12 Tributary Area Reduction Rl 1 Section 4.9 Sloped Roof Reduction R2 1 Section 4.9 Reduced Roof Live Load Lr 4= Lo(RI)(112) 1 Equation 4-7 2 Reduced Roof Live Load Lr 20 psf MPi 20.0 sf Reduced Ground Roof Live Snow Loads code Ground Snow Load pg 40.0 psf ASCE Table 7-1 Snow Load Reductions Allowed? Yes Effective Roof Slope 190 Horiz. Distance from Eve to Ridge W 15.7 ft Snow Importance Factor IS 1.0 Table 1.5-2 Snow Exposure Factor CV Partially Exposed Table 7-2 1.0 Snow Thermal Factor Ct Structures kept just above freezing Table 7-3 1.1 Minimum Flat Roof Snow Load(w/ Pf-min 30.8 psf 7.3.4&7.10 Rain-on-Snow Surcharge) Flat Roof Snow Load pf pf=0.7(Ce)(C0 (I) pg; pf? pf-min Eq: 7.3-1 30.8 psf 77% ASCE Design Sloped R Snow Load Over Surroundinq RoW Surface Condition of Surrounding CS roof All Other Surfaces Figure 7-2 Roof 1 1.0 Design Roof Snow Load Over P.0= (Cs-roof)Pf ASCE Eq:7.4-1 Surroundin Roof Ps-roof 30.8 Psf 77% ASCE Design Sloped R Snow Load Over PV Modules Surface Condition of PV Modules CS_PV Unobstructed Slippery Surfaces Figure 7-2 1.0 Design Snow Load Over PV Ps-p"= (CS_ )Pf ASCE Eq: 7.4-1 Modules PS p" 30.8 Psf 77% 09.05.2014 SleekMountTM PV System Version#38.7 SolarCity Structural Design Software PROJECT INFORMATION &TABLE OF CONTENTS Project Name: Kelley Residence AHJ: Northampton Job Number: 010401 Building Code: MA Res.Code,8th Edition Customer Name: Kelley,Richard G Based On: IRC 2009/IBC 2009 Address: 35 Fern St ASCE Code: ASCE 7-05 City/State: Northampton, MA Risk Category: II Zip Code 01062 Upgrades Req'd? No Latitude/Longitude: 42.343634 -72.675901 Stamp Req'd? Yes SC Office: Springfield PV Designer: William Avery Calculations: Justin Arbuckle EOR: Andrew White P.E. Certification Letter 1 Project Information, Table Of Contents, &Vicinity Map 2 Structure Analysis(Loading Summary and Member Check) 3 Hardware Design (PV System Assembly) 4 Note: Per IBC 1613.1; Seismic check is not required because Ss =0.22424 < 0.4g and Seismic Design Category(SDQ = B < D 1L2-MILE VICINITY MAP 9 ro 9 0 d?nmPs ogical Survey,-�EISDA Farm Service Agency 35 Fern St, Northampton, MA 01062 Latitude:42.343634,Longitude: -72.675901,Exposure Category:C Version#38.7 r�sSolarCit . - _ 3055 Clearview Way, San Mateo, CA 9440 2 (888)-SOL-CITY (755-2489) 1 wvnv_solarcity corn +n l t ', September 5 2014 , s r3 t)r at•�. "� N;;.4;%'0C± Project/Job#010401 � � cG+;;1 IMF`' RE: CERTIFICATION LETTER Project: Kelley Residence 35 Fern St Northampton,MA 01062 To Whom It May Concern, A jobsite survey of the existing framing system was performed by a site survey team from SolarCity. Structural review was based on site observations and the design criteria listed below: Design Criteria: -Applicable Codes = MA Res. Code,8th Edition,ASCE 7-05,and 2005 NDS -Risk Category= II -Wind Speed = 90 mph, Exposure Category C -Ground Snow Load =40 psf -MP1: Roof DL= 7 psf,Roof LL/SL= 30.8 psf(Non-PV Areas),Roof LL/SL= 30.8 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss =0.22424 < 0.4g and Seismic Design Category(SDC) = B < D On the above referenced project,the components of the structural roof framing impacted by the installation of the PV assembly have been reviewed. After this review it has been determined that the existing structure is adequate to withstand the applicable roof dead load,PV assembly load,and live/snow loads indicated in the design criteria above. I certify that the structural roof framing and the new attachments that directly support the gravity loading and wind uplift loading from PV modules have been reviewed and determined to meet or exceed structural strength requirements of the MA Res.Code,8th Edition. Please contact me with any questions or concerns regarding this project. Sincerely, Andrew White,P.E. Digitally signed by Andrew Structural Engineer White Main: 888.765.2489,x2377 Date:2014.09.05 13:58:51 -04'00' email: awhite @solarcity.com 3055 C IParview MlY Sin Mateo,GA 94402 i X650)638 1028 (888)",01-C1 TY i 4350)638-1029 -)Il W';ity(lull) DocuSign Envelope ID:5FD98DAC-5D2C-47DC-A3BD-D67156C42029 22.NOTICE OF RIGHT TO CANCEL. I have read this Power Purchase Agreement and the Exhibits in their YOU MAY CANCEL THIS CONTRACT AT ANY TIME PRIOR TO entirety and I acknowledge that I have received a complete copy of this MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE Power Purchase Agreement. YOU SIGN THIS CONTRACT. SEE EXHIBIT 1,THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN Customer's Name: Richard Kelley EXPLANATION OF THIS RIGHT. E/cu Signed by: 23.ADDITIONAL RIGHTS TO CANCEL. Signature: IN ADDITION TO ANY RIGHTS YOU MAY HAVE TO CANCEL THIS PPA UNDER SECTION 22,YOU MAY ALSO CANCEL Date: 9/1/2014 THIS PPA AT NO COST AT ANY TIME PRIOR TO COMMENCEMENT OF CONSTRUCTION ON YOUR HOME. 24.Pricing The pricing in this PPA is valid for 30 days after 9/1/2014. If you Customer's Name: don't sign this PPA and return it to us on or prior to 30 days after 9/1/2014,SolarCity reserves the right to reject this PPA unless you Signature: agree to our then current pricing. Date: SolarCity. Power Purchase Agreement SOLARCITY APPROVED Signature: �.•+"'" IYNDON RIVE, C[A (PPA) Power Purchase Agreement Date: 9/1/2014 DocuSign Envelope ID:5FD98DAC-5D2C-47DC-A3BD-D67156C42029 SolarCity. Here are the key terms of your SolarCity Power Purchase Agreement Date:- 9/1/zo- O 11000 20years System installation cost Electricity rate per kWh Agreement term Our Promises to You • We insure,maintain,and repair the System(including the inverter)at no additional cost to you,as specified in the agreement. • We provide 2417 web-enabled monitoring at no additional cost to you,as specified in the agreement. • We warranty your roof against leaks and restore your roof at the end of the agreement,as specked in the agreement. • The rate you pay for electricity,exclusive of taxes,will never increase by more than 2.90%per year. • The pricing in this PPA is valid for 30 days after 9/1/2014. • We are confident that we deliver excellent value and customer service.AS A RESULT,YOU ARE FREE TO CANCEL ANYTIME AT NO CHARGE PRIOR TO CONSTRUCTION ON YOUR HOME. Estimated First Year Production 12,344 kWh Customer's Name & Service Address Exactly as it appears on the utility bill Customer Name and Address Customer Name Installation Location Richard Kelley 35 Fern St 35 Fern St Northampton, MA 01062 Northampton, MA 01062 Options for System purchase and transfer: Options at the end of the 20 year term: • If you move,you may transfer this agreement to the purchaser of your • SolarCity will remove the System at no cost to you. Home,as specified in the agreement. • You can upgrade to a new System with the latest solar • At certain times,as specified in the agreement,you may purchase the technology under a new contract. System. • You may purchase the System from SolarCity for its fair • These options apply during the 20 year term of our agreement and not market value as specified in the agreement. beyond that term. • You may renew this agreement for up to ten(10)years in two(2)five(5)year increments. 888.SOL-CITY 1 888.765 2489 ; SOLARCITY.COM MA HIC 168572/MA Lic,MR-1136 Document Generated on 911/2014 244744 A R CERTIFICATE OF LIABILITY INSURANCE 0092,7014 IYYYy) oar2s:'2014 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: if the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in flau of such endorsement(s). PRODUCER NAME: MARSH RISK i INSURANCE SERVICES PHONE FAX 345 CALIFORNIA STREET,SUITE 1300 (AIC,No,On (AIC,No): CALIFORNIA LICENSE NO.0437153 1=0-B. SAN FRANCISCO,CA 94104 INSURERS)AFFORDING COVERAGE NAIC a 998301-STND-GAWUE-14.15 Liberty Muktai Fire Inswanog INSURER A: Company I 16586 INSURED Ph(650)963-5100 INSURER 0:LJDerty Ir"ance Corporabon 42404 Sdarcily Corporation INSURER C:N/A I NIA 3055 Cieavim Way San Mateo.CA 94402 INSURER 0: INSURER E: It INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-002440269-02 REVISION NUMBER:4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN. THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, E XCLUSIONS AND CONDITIONS OF SUCH POLICIES LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ;ADDL,Won � POLICY EFF POLICY EXP L TYPE OF INSURANCE _ wvo POLICY NUMBER M M YY LIMITS A GENERAL LIASIUTY T82.661-066265.014 ftDII2014 10KA10015 EACH OCCURRENCE s 1.000,000 X DAMAGE TO RENTED COMMERCUL GENERAL ItAHIIITY PREMISES(Es ociurenco} >: 100,000 CLAIMS MADE X I OCCUR I MED EXP(Any one person) 10,000 1 PERSONAL.b ADV INJURY :S 1,000"DOD ' GENERAI AGGREGATE $ 2,000.000 GEN'L AGGREGATE t WIT APPLIES PER PRODUCTS•COMP/OP AGG S 2.000,000 X I POLICY; X PRO• 'LOC I Deductible S 25.000 A AUTOMOBILE UA&UTY i AS2-661.066265-044 09/0112014 109MIMIS COMBINED SINGLE LIMIT 1,000.00D x ;tE-s ilecident) y ANY AUTO HOUR Y INJURY(Per person) S ALLOYMED SC IM DUI I-[) AUTOS AUTOS I BODILY WJURY(Peracc4arn) $ x ;HIREOAVIOS x hMEO AUTOS V fl ( I PRROPPEERT DAMAGE f$ x -PAys.Damage COMPICOLLDED: : $1.0001$1.0DO UMBRELLA LU18 OCCUR I EACH OCCURRENCE S I EXCESS LIAR I CLAIMS MADE, AGGREGATE $ DEU RETENTIONS 18 B WORKERS COMPENSATION WA7.66D-066265-024 090112014 ,0910112015 X VWSTATU- OTI/• B AND EMPLOYERS'LIAeIUTY .TORY LIMITS ER ANY PROPRIETOR .NERIEXt CUT iVE YIN 1W TORY I09T0112014 ON110015 I i.OD0,000 B OFFICERIMEMBER EXCLUDED IN 1NIJ I E L EACH ACCIDENT f (Mandatory in NHI 'WC DEDUCTIBLE:$350.000 I El DISEASE EA EMPLOYE[ $ 1.000.000 yes descnbe under DESCRIPTION OF OPERAI IONS beyw E L DISEASE POLICY LIMIT I S 1.000.000 i DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(AHach ACORD 101.Additional Remarks Schedule,if more space Is required) f vdeim o!Insuranoe CERTIFICATE HOLDER CANCELLATION SolarCity Corporation SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 3055 Clcarview Way THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN San Mateo.CA 94402 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh Risk a Insurance Services Charles Matmolejo ®1988.2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010105) The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts At Department of Industrial Accidents Office of Investigations 1 Congress Street,Suite 100 1 .j Boston,MA 02114-2017 www mass.gov/dia Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Agglicant Information Please Print Legibly Name(flusincWOrganiration/individual): SOLARC[TY CORP Address:3055 CLEARVIEW WAY Cit /Statc/Zi :SAN MATEO,CA 94402 Phone #:888-765-2489 Are you an employer?Check the appropriate box: Type of project(required): i.® I am a employer with 5000 4. ❑ i am a general contractor and 1 employees(full and/or part-time). • have hired the sub-contractors 6. ❑New construction 2.❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have 8. ❑Demolition working for me in any capacity. employees and have workers' q n Building addition [No workers' comp. insurance comp. insurance. required.] 5. ❑ We are a corporation and its 10.❑Electrical repairs or additions 311 t am a homeowner doing all work officers have exercised their 1 i.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGI, 12.❑ Roof repairs insurance required.]+ c. 152,§1(4),and we have no 13.1M Other SOLAR/PV employees. [No workers' comp. insurance required.] "My applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. +l iorneowners wino submit this affidavit indicating they are doing all work and then hire outside contractors muss submit a new affidavit indicating such lCoattactots that check this box must attached an additional shat shoving the name of the sub-contractors and state whether or not those entities have employees. If the sub-contraclors have cmployces.they must provide then workers'comp.policy number. I am an employer that is providing workers'compensation insurance far ntv ennployees. Below is the policy and Job site information. Insurance Company Name:_LIBERTY MUTUAL INSURANCE COMPANY Policy#or Self-ins. t.ic. I/:.WA7-66D-066265-024 Expiration Date:09/01/2015 to I=l�!Z,N � 1�1-o(tj'H I�MPTJ� � Job Site Address:___ _City/State/Zip: Oi o io'a. Attach s copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of M01,c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDFiR and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of investigations of the 131A for insurance coverage verification. I do hereby certify uruler tine Mains and penalties of perJrrry Nnof the information provider/above is true and correct. � n Off/cial use only. Do not write in this area,to be completed by city or town official. City or Town: —Permit/License ff__ Issuing Authority(circle one): 1.Hoard of Health 2. Building Department 3.City/Town Clerk 4.Flectrical Inspector S.Plumbing Inspector 6.Other Contact Person: Phone#: SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: �J Not Applicable ❑ Name of License Holder: -5Q 1a2 CO2P\ C ' Q-)(,�or-� License Number M .�2 1 UtvIT ---61 gm I �� Address Expiration Date ©11'� Signature I Telephone 9.Realstered Home Improvement Cgritractor: Not Applicable ❑ �LA(� C IT-1 C- 2P SAMFS ►l c.cl��•c` I 1�1i Company Name Registration Number �-1 ST r�2-�t t3 '�2 t_o 't Nv a V tJ'T t ( 3 I S� 15- dress l . Expiration D to CN-Nko \ ! Telephone SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes...... AL No...... ❑ 11. - Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,You may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors E3 Accessory Bldg. ❑ Demolition ❑ New Signs [p] Decks [M Siding[p] '5--�� RV Brief Description of Proposed So:t�rZ C�cc TCt�� (�A���S i o ao r Work: To CSC To 1-W3(nk'S CAELT(�tCNk S`ISTc-V Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building :One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1 as Owner of the subject property hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application. Signature of Owner Date 1, 5,;_A n � i�•) �o tt(�� S(�(nE S�\�c.�v.c� as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Pri ame e tip C1 _ S L Signaturk of Owner/Agent Date ' P Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department a Lot Size Frontage Setbacks Front Side L:' R: L: R: Rear Building Height Bldg. Square Footage % — Open Space Footage % (Lot area minus bldg&paved parking) #of Parking Spaces Fill: volume&Location) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO ® DONT KNOW © YES Q IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DONT KNOW ® YES IF YES: enter Book Page, and/or Document# B. Does the site contain a brook, body of water or wetlands? NO 0 DONT KNOW ® YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained © Obtained ® , Date Issued: C. Do any signs exist on the property? YES ® NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES 0 NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavation,or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES © NO IF YES,then a Northampton Storm Water Management Permit from the DPW is required. Department use only. - -- C ty of Northampton Status of Permit B�ilding Department Curb Cit/tslyeuy Pmit ►-u` 12 Main Street S warlSeptic kv llabllit�r S-�p ( 5 2Oi4 Room 100 WaterM+eilAvailaltlil u` ort ampton, MA 01060 1'woets`of Siiucittra!PlarrsY° L�—---- 7-1240 Fax 413-587-1272 fiotfSita Plar Electric, F{um Nor1hU:Ling np?�n. MIA 01060 Other e fy � APPLICATION TO CONSTRUCT,ALTER,REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office 5T Map Lot Unit Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: R�C-Vkp, "4 35 1-CRN s T No2TNIiAr^P r� rna Oto�a- Name(Print) Current Mailing Address: 4 - Si=b- L4 Vs Telephone Signature 2.2 Authorized Agent: o,-(a(z-C\T`I C7QP� �AMLS��P �� ail ST (tea ctr+�2 �3i y1tS�ic�� Vt�\I �l e(Print) Current Mailing Address: PaL. C)-) a300 b Signa re Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by ermit applicant 1. Building y O O (a)Building Permit Fee 2. Electrical Q (b)Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) 5. Fire Protection 6. Total=(1 +2+3+4+5) O O b Check Number .� This Section For Official Use Only Date Building Permit Number: Issued: Signature: Building Commissioner/Inspector of Buildings Date File#BP-2015-0291 APPLICANT/CONTACT PERSON SOLARCITY CORP ADDRESS/PHONE 24 ST MARTIN DR BLDG 2,UNIT 11 MARLBORO (888)765-2489(2358) PROPERTY LOCATION 35 FERN ST MAP 16B PARCEL 031 001 ZONE URB000) THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid Typeof Construction:_INSTALL 28 SOLAR PANEL 7.14 KW TO ROOF New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 107663 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Demolition lay Sign e ZoMWJineWicial Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning& Development for more information. 35 FERN ST BP-2015-0291 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 16B-031 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR PANELS BUILDING PERMIT Permit# BP-2015-0291 Project# JS-2015-000555 Est. Cost: $18000.00 Fee: $108.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: SOLARCITY CORP 107663 Lot Size(sq. ft.): 10018.80 Owner: KELLEY RICHARD G Zoning: U1zB(100)/ Applicant: SOLARCITY CORP AT. 35 FERN ST Applicant Address: Phone: Insurance: 24 ST MARTIN DR BLDG 2 UNIT 11 (888) 765-2489 (2358) Workers Compensation MARLBOROMA01752 ISSUED ON.9/16/2014 0:00:00 TO PERFORM THE FOLLOWING WORK.-INSTALL 28 SOLAR PANEL 7.14 KW TO ROOF POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeTvpe: Date Paid: Amount: Building 9/16/2014 0:00:00 $108.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner