25C-071 (7) KI 7(HEN IJ IN caLt.r ets) h*, r v U tv -2 (LLO S-E-1 CP U) LL 0 -1 Vi Qj ag 'n ro OZ 43 LL X Z: -z_ LQ -1 WJ LU b-lk LSJ QF vr LINEN X, CLOSET Noot< (a4 < I N 7/7" x F 7,c,; SE , 4' h` -7 1,4 -7 -7 L to DIN IQ 6 FA I^ 4-Y DANI AND DENISE MCKAHN UP TO 42"WINDOW HEADER: ATTIC LEVEL 9 1/2"LVL-BEARING JACKS 4x4 P=4053#@ CTR 41LDAY AVENUE,NORTHAMPTON,MA APPROX. 12' STRUCTURAL ANALYSIS/RECOMENDED CHANGES a, JEFF PENN 413-667-5230 2 JULY 2014 APPROX. 13' Q , REPLACE 1"x(7")RIDGE SCALE: 1/4"=F-0" WITH: EXISTING EXISTING 7"x11 7/8"PSL 2"x4"@ 24"oc SCALE - —— - 2"x8"VALLEY JACK STUDS l ADD 2x8 0 1' 5' 10' �i VERIFY LOAD PATH VERIFY LOAD PATH BEARING TO GRADE BEARING TO GRADE -" ti�ti 4x4 POST P=3120# NOTE: 4x4 POST P=2496# ` o� �6 EXISTING ENGINEERED LUMBER s� 2"x8"VALLEY TECH TO RECALCULATE ADD 2-7 1/4"LVL'S AND SUPPLY STAMPED DESIGNS ALSO,4x4 POSTS SHOULD ALL BE LVL MATERIAL EXISTING M=MOMENT FOR DESIGN CHIMNEY P=POINT LOAD POUNDS VERIFY LOAD PATH o, N � BEARING TO GRADE ,� ALL ALL 1/2 x5 1/4 PSL POST 3 O EXISTING P=9412 EXISTING a2"x6"@ 24"oc 2"x6"@ 24"oc Q RAFTERS CUT VALLEYS; FLOOR JOISTS ADD: EXISTING HANG TO RIDGE ADD: 5 1/2"LVL'S @ 24"'oc 2"x8"VALLEY 5 1/2 ��LVL'S @ 24 oc REPLACE WITH: EXISTING 51/4"x11 7/8"PSL ' 2"x8"VALLEY ADD: SECURE RAFTERS TO RAFTER PLATES cab^ REPLACE 31/2"x91/2"PSL AND WALL USING HURRICANE TYPE ' ,� 1"x(7")RIDGE STRAPS AND VERIFY FLOOR WITH: STRUCTURE BEARING AND TIE 7"x117/8"PSL �8ro EFFECT NC, 3'UN � APPROX.44' UP TO 42"WINDOW HEADER: 9 1/2"LVL-BEARING JACKS 4x4 P=5506#9 CTR PERFORMANCE COMPLIANCE METHODS TABLE 1301.7 SUMMARY SHEET—BUILDING CODE Existing occupancy Proposed occupancy_ 4L.1— Year building as constructed li' g Number of stories 3 _Height in feet ?2 Type of construction E�7 Area per floor 0 Z ?D F Percentage of open penmeter increase Completely suppressed: Yes No _ Corridor wall rating Compamnentation: Yes No Required door closers: Yes No _ Fire-resistance rating of vertical opening en lo Type of HVAC system 1 ADt tt1�C��L Al, 41196, M IA 112tj serving number of floors Automatic fire detection: Yes _ yp No e and location Fire alarm system: Yes No Type 1 1 Smoke control: Yes No_�, Type Adequate exit routes: Yes _ No Dead ends: Yes No X _ r Maximum exit access travel distance Z Elevator controls: Yes No X Means of egress emergency lighting: Yes —X—No Mixed occupancies: Yes No x SAFETY PARAMETERS FIRE SAFETY(FS) i MEANS OF EGRESS(ME) GENERAL SAFETY(GS) 1301.6.1 Building Height ' — ? — "] — 7 7 1301.6.2 Building Area -4— 4- 1301.6.3 Compartmentation 1301.6.4 Tenant and Dwelling Unit Separations O O 1301.6.5 Corridor Walls O D p 1301.6.6 Vertical Openings 'l I --� 1301.6.7 HVAC Systems rj S 1301.6.8 Automatic Fire Detection (p (p CIO 1301.6.9 Fire Alarm System } D O O 1301.6.10 Smoke control ** I 1301.6.11 Means of Egress *** O O 1301.6.12 Dead ends ** Z 2 1301.6.13 Maximum Exit Access Travel Distance *# ? 1 1301.6.14 Elevator Control 2, i — 2 1301.6.15 Means of Egress Emergency Lighting 3412.6.16 Mixed Occupancies 3412.6.17 Automatic Sprinklers — �n 2 = —40 3412.6.18 Standpipes * ** O 3412.6.19 Incidental Accessory Occupancy Building score—total value ****No applicable value to be inserted. f 68 2009 INTERNATIONAL EXISTING BUILDING CODE® Simple Fire Narrative The building has smoke detectors and alarms throughout. In the event of a smoke or fire event, the detectors will sound alarm throughout the building and battery-backup emergency egress lighting will assist occupants in accessing the stair with clearly marked Exits. One Exit accesses the front of the building and the other access the rear of the building; both grade exits are adjacent to the parking and occupants may return to the front along a walk. An occupant of the building noticing a fire or smoke event will also have access to 3 fire extinguishers (near main entry each level). will add 5 1/2" LVL's at 24"oc augmenting the existing 2"x6" @ 2499oc joists. During design and when opening structure, any further encountered deficiencies shall be remedied. The owner welcomes the building official's comments regarding any perceived dangerous conditions for remedy. I will provide analysis of the structure as revealed. Additional Explanations and Information Site The site is a typical building lot on Day Avenue platted in 1890 with driveway, garage and back yard in addition to the house. The building is approx. 40' from side neighbors but approx. 21'-6" from the neighbor's garage. Change of Occupancy (307) 307.1 Conformance. Addition of one residential unit for a total of 3 makes the building subject to IBC 2009, the Commercial Code with several ramifications. The building will meet the code using Chapter 13, Performance Compliance Methods. 307.2 Certificate of Occupancy. Will be sought upon completion of project. 307.3 Stairways. the existing space and construction does not allow a reduction in pitch or slope. Separation and protection shall be accomplished 307.4 Structural. I believe this to be an ordinary structure and the change of occupancy is within Residential. The attic floor structure and bearing as well as the dormer structure shall be augmented to code. The addition of new interior walls will strengthen the lateral performance. 307.5 Energy. The new unit will meet the Stretch Code Energy code (Northampton is a Green Community). 307.6 Electrical. The new construction shall comply. 307.7 Fuel gas. The buildings HVAC and fuel supply shall comply. 307.8 Mechanical. The building systems shall comply. 307.9 Plumbing. The new construction shall comply. Historic Buildings (308) 308.1 —the building is located in a potential historic district; all effort will be made to maintain the period character even with the addition of windows and skylights. Accessibility for Existing Buildings (3 10) 310.1 Scope. Exception: type B dwelling or sleeping units... are not required... (when) change of occupancy. There is no intent to furnish an Accessible Apartment, parking or pathway at present. IBC 1107.6.2 shows that type A units are required for 20 or more units (2% or min. 1), no accessible units are required for R-2 apartment buildings and type B units are excepted in IEBC 310.1, thus there is no requirement for accessible units. 1301.6.5 — Corridor Walls —with the egress stair, small corridors and apartments all separated with 1 hr protection (using intumescent paint) the building will be category c = 0 1301.6.6 —Vertical Openings — with the egress stair and apartments separated with lhr protection, the value (1) x VB construction factor (7) = 7 1301.6.7 —HVAC Systems — each level is a separate unit with its own heat and cooling without ductwork connecting levels for category e = 5 1301.6.8 —Automatic Fire Detection—the owners will install a fire detection system in compliance with IBC section 907 for category e = 6 1301.6.9 —Fire Alarm System —the owners will install an alarm system in compliance with IBC 907 for category c = 0 1301.6.10 — Smoke Control —the egress stairs (front and rear) will be 1 hour protected and each stair has operable windows for category f= 4 1301.6.11 — Means of Egress—the egress stairs (front and rear) are existing and provide safe passage but are requested to be accepted as a Compliance Alternative due to the narrowness of passage and steepness of stairs. Both stairs are marginal with approx. 7 3/4" risers and 9" treads (plus nosing): the front stair is more than 36" wide throughout, but the rear stair and corridor are only 32" wide. The front stair currently has a path thru a second floor apartment room which will be isolated as a landing using 1 hour protection (intumescent paint). Despite the width, we think the rear stair constitutes a safe additional egress; there is no real hazard identified (as 32" doorways are considered safe passage). If accepted, the stairs meet category b = 0 1301.6.12 — Dead Ends — each unit has doors directly into front and rear egress stairs or corridors less than 10' to stairs (there are no dead end corridors) for category c = 2 1301.6.13 — Maximum Exit Travel Distance —the most remote point in any apartment is less than 25 feet from the egress stair, thus 20x(200-25/200) = 17 1301.6.14 — Elevator Control —there is no elevator and the second floor is approximately 25 feet above grade thus category a = -2 1301.6.15 — Means of Egress Emergency Lighting—the owners will install Exit signs at each level egress stair door which will include battery-backup emergency egress lighting for the stair hall on each level and within the stairs for category c = 4 1301.6.16 — Mixed Occupancies —there are no mixed occupancies = 0 1301.6.17 — Automatic Sprinklers—there are no sprinklers but they are required thus category a = -6 1301.6.18 — Standpipes—none are required for category b = 0 1301.6.19 — Incidental Accessory Occupancies —the basement contains the furnace for the first floor without ceiling protection in Table 13 01.6.19 = -1 Structural Analysis The architect has identified two main areas of structural deficiency; the attic floor joists, and the framing at both dormers. For the Dormers, I recommend installation of a 3 1/299x 117/8" LVL bearing ridge for each to be supported by LVL headers and additional LVL rafters. For the floor joists to bear 40# live and 12# dead loads, we ARCHITECT J E F F R E Y S C O T T P E N N 77 Worthington Road,Huntington,MA 01050 tel.413-667-5230 fax.413-667-3082 isspsed @v_erizon.net 2 July 2014 Investigation and Evaluation Client: e°` Danielle and Denise McKahn ,' 42 Day Avenue Northampton, MA 01060 � General The McKahn residence at 42 Day Ave. is currently a two story two family residence with unoccupied attic, built c. 1895. The building was renovated over the last 5 years with structural and energy upgrades properly done under a building permit. The new proposed project is to add an additional housing unit for a total of 3 which will change the building occupancy from R-3 to R-2. The new unit will be contained on the third level with primary access at the street front stair with secondary egress at the rear stair. The building is Type VB construction with wood stud Balloon frame and typical finishes (at Table 503 VB allows maximum use for R-2 of 2 stories and 7000sf). It is my understanding that some criteria are waived if the whole building satisfies one of the Compliance methods (IEBC 101.5.3), such as the maximum number of floor levels. The intent is to add fire detection and alarms, add exit signage and emergency egress lighting and protect the structure of the egress Stairways, front and rear. The 3 story building footprint is approx. 1,400 sq. ft. and the height approx. 35'; table 503 shows maximum 40 feet height, 2 stories and 7,000 sf footprint for R-2 (table 601 identifies VB construction due to ratings). I have reviewed relevant citations in the IEBC Performance Compliance Methods, chapter 13, and provide the following results of the investigation and evaluation. Chapter 13. Performance Compliance Methods 1301.6.1 —Building Height—the lower number is due to the building not complying with Table 503 maximum of 2 stories (will have 3), thus -1 x 7 = -7 1301.6.2 —Building Area—the greatest deduction is for the first floor at 1,390sf/7000sf allowable x 7000/1200 = 4.6 = 4 1301.6.3 — Compartmentation—the whole building's net area is 2,766sf at Table 1301.6.3 = 16 1301.6.4 —Tenant and Dwelling Unit Separation—the egress stair has doors at each level but is less than 1 hour protected—using Contego Intumescent Paint, the owners will protect the stair (including doors, corridors and apartment sides of the walls and apartment ceilings) to 1 hr for category c = 0 ARCHITECT J E F F R E Y S C O T T P E N N 77 Worthington Road,Huntington,MA 01050 tel.413-667-5230 fax.413-667-3082 nsed@verizon.net 2 July 2014 Client: Danielle and Denise McKahn 42 Day Avenue Northampton, MA 01060 Northampton Building Department Puchalski Municipal Building, Town Hall 212 Main Street Northampton, MA 01060 Dear Louis and Chuck: Danielle and Denise have asked me to assist them in assessing and planning their proposed renovation at 42 Day Avenue. After reviewing your preliminary comments and further code research, I have used the IEBC chapter 13, Performance Compliance Methods. I have produced the attached Investigation and Evaluation. To summarize, adding one unit brings the building from Use Group R-3 to R-2, and requires compliance with IBC 2009, the Commercial Code, or modifications to satisfy Table 1301.7 for Perfomance Compliance. Thus we are outlining our intention to add fire detection and alarms, add exit signage and emergency egress lighting and protect the structure of the egress Stairways, front and rear, and apartment separations by using Contego Intumescent paint (or approved equal). We believe this path reveals no requirement to add a fire suppression sprinkler system. We welcome your input and will be happy to furnish required information. The owner will produce building plans for a Building Permit. Thank you &;p Jeffrey Sc tt Penn, Architect The C"onnnotrweallh qf1lasvirt.-husetts, Department qf,Industrial A Ceidents Yffee Of M 1w vii",alio its I Con,,WssStreet, Suile /00 Roston,MA 02114-2017 wwIv.11111"t,"V.go v1dia Workers, Compensation Insurance Affidavit: Applicant Information Please Prilqjx: ibl�� LAJ Q 111z AddTVYI: l 9 7 pq 1C. Phone Are Ami =lit emidoyer?C reek Ilt c a p p ro riate box: TYpe orproject(requiredy LI I xll ;I fl`111110:%'Cr \,;11' I. am ontrlloov 1md I %c%I, C I I I.1 1 11 u I.lUiT :111plo\cc, 0 JI and'or pa ii, timcf, dw onitoklor, hall ('11 flic s111.tdwd Ilbcct. L hill itild hav" no emplova's Vhcsc it ti,) ba�C -rC Ct's and lul,.C workct` "voll, 1,01'file lit Wiv Capacity, Comp. IO'n W�-:irc a corporation and itr, ZI(I(ji dn lwve cv,�Fcl�cd OwIT oi �,, id I, l �w I, mv,(Jl INo k:olfl ), i0ll I"Ll- Nl(;l j rquired.] C. f, ;Ind Ii I,1javc ifo cniploNccs, [No work-aS* Olhcv COMP. 1111"urance required. Av�,� ,pplwxfl that cimi, box#I Imist ajso JM oto thc"o'-1 wi�hCh',,k Olowing 0161 sk o'k,c1 M pohl lk tnt'of Imo irIII III W,111 'N ho y,uhm if¢1714:Ij I I&I vii itAtic-al I Ile t hev aw doilig Al%w-L and Ilion 11 fw outsid,,' `.01111'3,101 S it mst solmlit a 1w,%S a I't ida\it lild I:.at ilm tich Jl; J, Ow,ho"mw;;Iwodwd an addWmml shco tj)c waow of dw 1118-i;offlt,'I,AIIII 171111 sl'ov%,tw(I'Ln m It I11011" it C ,MCI MW! J,J 1. it pA1.\ mmlhca am em emlohqer that is proritfilig wonker-8'compoisatioti iusuranccfi)r mt7 emploj-ee18. /)"cloov itI 111cpalik-c and job 4fc (n,,mr;mc,t1,('omparn, Namci Pollc\­ ot Sell, i •l. h(:, Joh, Ntladja cop of the workers, comjwlvwation policy (Icclaratioll paler(SlIoNNitw the policy number alld v\pir.lfion date). klihtc to sccurc Cov(:,ragc as rt;quilvd under Soction of'.M(A,c. I 5_2 can lead to Zhu imposition of criminal penalue",.of ',I filic (,tp to 4,1,500,00 atld:ol Ofiv Vv'U1,if at,wcIl as CiI,it pemi,Atie, in the 1,01 of of a SIT()V FORK (If-\I)FIR tmid a tiiw, OfUl)tO Sl"­�OMO A&W the violatol, fie advi"Ij that a coliv of this statement may he forw,,Ivded to tht,00-14:e(Ij Inves'livations of Ow I)VA f*Or L'(WtT�11"C VCHfi ,-�Jon� I do here hlv wider the paito andpowltio qfperjurr Mal the in.fi)rnsation provided about,is Irm,and twrrecr o . __7 .�7 F'ficial ust,only Dee lm/write in thiv area, iv he compkied h),rity or fown tWit'lal C6 hmn: t F,� 1 11 ori1v (cirvIc one): L Roard of licalth 1 Building Department 3.Cioll!'Towit Clerk 4, Electrical inspector S. 1,111111I)i1lo 111-sitc•tor 6, Other Contact Person: Pholic II.- Versionl.7 Commercial Building Permit May 15,2000 SECTION 10-STRUCTURAL PEER REVIEW(780 CMR 110.11) Independent Structural Engineering Structural Peer Review Required Yes 0 No O SECTION 11 -OWNER AUTHORIZATION -TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Denise and Danielle MCKahn as Owner of the subject property hereby authorize Kevin Werner to act on my behalf, in all matters relative to work authori ed by this buil ing permit application. ` ✓L1 6 26 �� Signature of Owner Date Danielle MCKahn as Owner Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. P44$CIle T 114 �/�'• h n Print Nam Signature of Owner/Ag nt Da e SECTION 12-CONSTRUCTION SERVICES 10.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder: Kevin Werner CSI 085114 License Number 197 Parmenter Road, Bernardston, MA 01337 08/18/2015 Address Expiration Date �� (413) 834-0488 Signature Telephone SECTION 13-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes O No 0 5 D (C.P�-� 2 C)Pr r�-yPrgL� Versionl.7 Commercial Building Permit May 15,2000 4 Nt pry A.hy T-&t i SECTION 9-PROFESSIONAL DESIGN AND CONSTRUCTION SERVICES-FOR BUILDINGS AND STRUCTURES SUBJECT TO CONSTRUCTION CONTROL PURSUANT TO 780 CMR 116(CONTAINING MORE THAN 35,000 C.F.OF ENCLOSED SPACE) 9.1 Registered Architect: Not Applicable ❑ Name(Re istrant): �l AR 9525 X_14 A Registration Number Address 08/31/2014 (413)I (413) 667-5230 Expiration Date Qnfaju I Telephone 9.2 Registered Pro essional Engineer(s): Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date 9.3 General Contractor Kevin Werner Company Name: Not Applicable ❑ Responsible In Charge of Construction Address Signature Telephone 1 Version 1.7 Commercial Building Permit May 15,2000 SECTION 9-PROFESSIONAL DESIGN AND CONSTRUCTION SERVICES-FOR BUILDINGS AND STRUCTURES SUBJECT TO CONSTRUCTION CONTROL PURSUANT TO 780 CMR 116(CONTAINING MORE THAN 35,000 C.F.OF ENCLOSED SPACE) 9.1 Registered Architect: 'Ti-cfPcey Sc-D-w ptmm Not Applicable 0 9525 Name(Registrant): AR 77 \jV0F?,T irk jt4(,T0Aj FelD, tju.-jT*,,VG7'lD" MA C)JiDSO Registration Number — 08/31/2014 Address (413) 667-5230 Expiration Date Signature Telephone 9.2 Registered Professional Engineer(s): Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date 9.3 General Contractor Kevin Werner Not Applicable 0 Company Name: KEviN WER141EK Responsible In Charge of Construction 1?"7 01137 Addre-- 831 -0+88 ;,g 4a� Telephone Versionl.7 Commercial Building Permit May 15,2000 8. NORTHAMPTON ZONING Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size 7,510 7,510 Frontage 74.52 74.52 Setbacks Front 10 10 Side L: 31 R: 14 L.31 R: 14 Rear 42 42 Building Height 35 35 Bldg. Square Footage 2117 28 % 2117 28 Open Space Footage % (Lot area minus bldg&paved 4046 54 4046 54 parking) #of Parking Spaces 5 5 Fill: (volume&Location) None 13 None 13 A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO 0 DON'T KNOW 0 YES O IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO O DON'T KNOW Q YES O IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW 0 YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained O Obtained O , Date Issued: C. Do any signs exist on the property? YES Q NO O IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property ? YES O NO O IF YES, describe size, type and location: E. Will the construction activity disturb(clearing, grading,excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES O NO O IF YES,then a Northampton Storm Water Management Permit from the DPW is required. 3 Versionl.7 Commercial Building Permit May 15,2000 SECTION 4-CONSTRUCTION SERVICES FOR PROJECTS LESS THAN 35,000 CUBIC FEET OF ENCLOSED SPACE Interior Alterations ✓❑ Existing Wall Signs ❑ Demolition❑ Repairs❑ Additions ❑ Accessory Building❑ Exterior Alteration ❑ Existing Ground Sign❑ New Signs❑ Roofing❑ Change of Use❑ Other ❑ Brief Description Adding a third unit to an existing two family home Of Proposed Work: SECTION 5-USE GROUP AND CONSTRUCTION TYPE USE GROUP(Check as applicable) CONSTRUCTION TYPE A Assembly ❑ A-1 ❑ A-2 ❑ A-3 ❑ 1A ❑ A-4 ❑ A-5 ❑ 1B ❑ B Business ❑ 2A ❑ E Educational ❑ 2B I ❑ F Factory ❑ F-1 ❑ F-2 ❑ 2C ❑ H High Hazard ❑ 3A ❑ I Institutional ❑ 1-1 ❑ 1-2 ❑ 1-3 ❑ 3B ❑ M Mercantile ❑ 4 ❑ R Residential ❑✓ R-1 ❑ R-2 ❑✓ R-3 ❑ 5A ❑ S Storage ❑ S-1 ❑ S-2 ❑ 5B U Utility ❑ Specify: M Mixed Use ❑ Specify: S Special Use ❑ Specify: COMPLETE THIS SECTION IF EXISTING BUILDING UNDERGOING RENOVATIONS,ADDITIONS AND/OR CHANGE IN USE Existing Use Group: R3 Proposed Use Group: R2 Existing Hazard Index 780 CMR 34): 2 (6th Edition) Proposed Hazard Index 780 CMR 34): 2 (6th Edition) SECTION 6 BUILDING HEIGHT AND AREA BUILDING AREA EXISTING PROPOSED NEW CONSTRUCTION OFFICE USE ONLY Floor Area per Floor(so 1st 1,370 1st 1,370 2nd 1,300 2nd 1,300 3rd 3rd 819 4th 4th Total Area(so 2,670 Total Proposed New Construction(so 819 Total Height(ft) 8 Total Height ft 35 Whai1 Vvi1�F�iv� exiS irk Structure 7.Water Supply(M.G.L.c.40,§54) 7.1 Flood Zone Information: 7.3 Sewage Disposal System: Public ✓❑ Private ❑ Zone Outside Flood Zoned Municipal [Z] On site disposal system❑ 2 FO Versionl.7 Commercial Building Permit May 15,2000 o Department use only City of Northampton Status of Permit: ay O t, Building Department Curb Cut/Driveway Permit - 212 Main Street Sewer/Septic Availability Room 100 WaterM/ell Availabilitv Northampton, MA 0106, ,y phone 413-587-1240 Fax 413 APPLICATION TO CONSTRUCT,REPAIR, RENOVATE, H ANY BUILDING OTHER THAN A I SECTION 1 -SITE INFORMATION 1.1 Property Address: _____ office 42-4 Day Avenue Map Lot Unit Northampton, MA 01 060 Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Denise A. and Danielle J. McKahn 42 Day Avenue, Northampton, MA 01060 Name(Print) Current Mailing Address: (413) 320-7208 Signature o v /�.ahjp/�U--Telephone 2.2 Authorized Agent: Kevin Werner jQ'7 P+ARM,CN9'ER )gyp, $ERPlA0t0.s7'*A/ Name(Print) Current Mailing Address: 1A A 01/37 (413) 834-0488 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by ermit applicant 1. Building $65,000.00 (a) Building Permit Fee 2. Electrical ,b) Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) 5. Fire Protection 6. Total=(1 +2 +3+4+ 5) I J 65 000 I Check Number This Section For Official Use Only Building Permit Number Date Issued Signature: Building Commissioner/Inspector of Buildings Date L File#BP-2015-0061 APPLICANT/CONTACT PERSON KEVIN WERNER ADDRESS/PHONE 197 PARMENTER RD BERNARDSTON (413)834-0488 PROPERTY LOCATION 42 DAY AVE MAP 25C PARCEL 071 001 ZONE URB(100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid Typeof Construction:_CONVERT 2 FAMILY INTO 3 New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 085114 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INF RMATION PRESENTED: Approved Additional permits required(see below) �L— PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Demolition Delay Tbby Signature of Building Official Date Note: Issuance of a Zoning permit does not relikve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of Planning&Development for more information. 42 DAY AVE BP-2015-0061 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 25C-071 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: Building BUILDING PERMIT Permit# BP-2015-0061 Project# JS-2015-000121 Est. Cost: $65000.00 Fee: $390.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: KEVIN WERNER 085114 Lot Size(sq. ft.): 7318.08 Owner: KAHN DANIELLE J&DENISE A MCKAY Zonin : URB(100)/ Applicant. KEVIN WERNER AT. 42 DAY AVE Applicant Address: Phone: Insurance: 197 PARMENTER RD (413) 834-0488 WC BERNARDSTONMA01137 ISSUED ON.9/9/2014 0:00:00 TO PERFORM THE FOLLOWING WORK.CONVERT 2 FAMILY INTO 3 POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy signature: FeeType: Date Paid: Amount: Building 9/9/2014 0:00:00 $390.00 212 Main Street,Phone(413)587-1240, Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner