06-039 (16) FINAL REPORT /APPROVAL DOCUMENT CONSTRUCTION CONTROL AFFIDAVIT PROJECT NUMBER: 0482-04-13 DATE: 8-29-2014 PROJECT TITLE: Zoe Senior Retirement Community PROJECT LOCATION: 345 Haydenville Road, Northampton, Ma BUILDING PERMIT No. B-2013-1095 SCOPE OF PROJECT: Zoe Senior Retirement is a 3-story steel and wood conventionally framed assisted living center with 85 units.The site improvements associated with the development of the subject parcel include new driveways, parking areas, sidewalks, landscaping, stormwater management features, and typical underground utilities. IN ACCORDANCE WITH SECTION 1704 OF THE 8TH EDITION OF THE MASSACHUSETTS STATE CODE, I, Frank A DeMarinis P.E.- 199 Servistar Industrial Way Suite 2.Westfield, MA 413-562-4884 Name Address Phone Number MASSACHUSETTS REGISTRATION NO.41640 BEING A REGISTERED PROFESSIONAL ENGINEER HEREBY CERTIFIES THAT I HAVE PREPARED, DIRECTLY SUPERVISED AND/OR RETAINED OTHER DESIGN PROFESSIONALS FOR THE PREPARATION OF ALL DESIGN PLANS, COMPUTATIONS AND SPECIFICATIONS CONCERNING: X ARCHITECTURAL X STRUCTURAL X CIVIUSITE/FOUNDATION (specify) FOR THE ABOVE NAMED PROJECT AND THAT, TO THE BEST OF MY KNOWLEDGE, SUCH PLANS, COMPUTATIONS AND SPECIFICATIONS MEET THE APPLICABLE PROVISIONS OF THE 8T" EDITION OF THE MASSACHUSETTS STATE BUILDING CODE, ALL ACCEPTABLE ENGINEERING PRACTICES AND ALL APPLICABLE LAWS FOR THE PROPOSED PROJECT. I FURTHER CERTIFY THAT I SHALL PERFORM THE NECESSARY PROFESSIONAL SERVICES AND BE PRESENT ON THE CONSTRUCTION SITE ON A REGULAR AND PERIODIC BASIS TO DETERMINE THAT THE WORK IS PROCEEDING IN ACCORDANCE WITH THE DOCUMENTS APPROVED FOR THE BUILDING PERMIT AND SHALL BE RESPONSIBLE FOR THE FOLLOWING AS SPECIFIED IN SECTION 1704: 1. Review of shop drawings,samples and other submittals of the contractor as required by the construction contract documents as submitted for building permit,and approval for conformance to the design concept. 2. Review and approval of the quality control procedures for all code-required controlled materials. 3. Special architectural or engineering professional inspection of critical construction components requiring controlled materials or construction specified in the accepted engineering practice standards listed in Section 1704.0. 1 hereby certify that the work performed meets the applicable provisions of the 780 CMR(8T"edition of the Massachusetts State Building Code), all accepted engineering practices, and all applicable laws for the proposed project. I believe the above mentioned portion of the work to be completed and I am submitting to the building official, via the Design Professional in Responsible Charge, this"Final Report/Approval Document"as to the satisfactory completion of the above mentioned portion of the work alon ny associated code punch list items remaining to be completed. (See attached—' E��y► Of yqs'�► FRANK A. �y6 Signature DEMARINIq CIVIi_ -r w No,41640 H —� MA