24A-199 (2) MEMBER REPORT Level,Floor:Flush Beam ;�N19
-� "
RTE PASSED
3 piece(s) 1 3/4" x 7 1/4" 1.9E Microllam0 LVL
Overall Length:9'8"
il/,
� / / =
+ i o
gm,
9'B..
0
All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal.
Cl4SI NN RBt...- its, dtt dtN Atlawed, i Re>"ult b '1 oadt bint System:Floor
Member Reaction(Ibs) 2081 @ 1 1/2" 6694(3.00") Passed(31%) 1.0 D+1.0 L(All Spans) Member Type:Flush Beam
Shear(Ibs) 1713 @ 10 1/4" 7232 Passed(24%) 1.00 1.0 D+1.0 L(All Spans) Building Use:Residential
Moment(Ft-Ibs) 4772 @ 4'10" 10672 Passed(45%) 1.00 1.0 D+1.0 L(All Spans) Building Code:IBC
Live Load Defl.(in) 0.166 @ 4'10" 0.235 Passed(L/680) 1.0 D+1.0 L(All Spans) Design Methodology:ASD
Total Load Defl.(in) 0.256 @ 4'10" 0.471 Passed(L/442) 1.0 D+1.0 L(All Spans)
•Deflection criteria:LL(L/480)and TL(L/240).
Bracing(Lu):All compression edges(top and bottom)must be braced at 9'8"o/c unless detailed otherwise.Proper attachment and positioning of lateral
bracing is required to achieve member stability.
h BSI ?91 PIP
tar#� �b14 r
Su I;ksr T : ',7ts rtaltnt� Refit► De er.1 � rteC i r.
1-Stud wall-SPF 3.00" 3.00" 1.50" 727 1353 2080 Blocking
2-Stud wall-SPF 3.00" 3.00" 1.50" 727 1353 2080 Blocking
-Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
1-Uniform(PSF) 0 to 9'8" 14' 10.0 20.0 Residential-Living Areas
MembexNotes ,
RYAN REGAN-LADD
BISSETT/KOERBEL RES.
36 MURPHY TERR.
NORTHAMPTON,MA
s';. - `` ✓ Fr) „�., C,Z}J SUSTAINABLE FORESTRY INITIATIVE
wP�fPwl�1tiP�Uf Td�'S. _
Weyerhaeuser warrants that the sizing of its products will be in actor nce with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the are.Refer to current Weyerhaeuser literature for installation details.
(www.woodbywy.com)Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Use of this software is not intended to
circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to
assure that this calculation is compatible with the overall project.Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable
forestry standards.
The product application,input design loads,dimensions and support information have been provided by Forte Software Operator
Forte Software Operator Job Notes 7/16/2014 12:36:56 PM
Peer van Buren —--— --- ---—-� Forte v4.1,Design Engine:V5.7.0.245
Co,•.Ts Building Supply RRL-BISSETT KOERBEL RES.4te
14131 5-44-0001
:e- co fs.con' Page 1 of 1
i