Loading...
36-358 (4) :3 3� Home Energy Rating Certificate Regiumber 13-426568 Rating Number 13-426 Certified Energy Rater John Saveson 91 Emerson Way Rating Date 7/21/14 Northampton, MA 01062 Rating Ordered For r- J r. Estimated Annual Energy Cast Ll Use MMBtu Cost Percent 5 Stars Plus Heating 58.7 $810 37% Confirmed HERS Index: 53 Cooling 3.0 $141 6% Hot Water 16.8 $222 10% Lights/Appliances 24.6 $1045 47% General Information Photovoltaics -0.0 $-0 -0% Conditioned Area 2488 sq. ft. House Type Single-family detached Service Charges $0 0% Conditioned Volume 30773 cubic ft. Foundation More than one type Total 103.1 $2218 100% Bedrooms 4 Criteria Mechanical Systems Features This home meets or exceeds the minimum criteria for the following: Heating: Fuel-fired air distribution, Natural gas, 95.0 AFUE. Cooling: Air conditioner, Electric, 13.0 SEER. Water Heating: Instant water heater, Natural gas, 0.94 EF, 0.0 Gal. Duct Leakage to Outside 0.00 CFM25. Ventilation System Exhaust Only: 68 cfm, 8.7 watts. Programmable Thermostat Heat=Yes; Coot=Yes Building Shell Features Ceiling Flat R-48.1 Slab R-0.0 Edge, R-0.0 Under Sealed Attic NA Exposed Floor R-32.4 Vaulted Ceiling R-43.0 Window Type U-Vatue: 0.300, SHGC: 0.280 Above Grade Walls R-21.0 Infiltration Rate Htg: 585 Clg: 585 CFM50 Center For EcoTechnology Foundation Walls R-9.0 Method Blower door test 320 Riverside Dr 1-A Lights and Appliance Features Northampton, MA 01062 413-586-7350 Percent Interior Lighting 100.00 Range/Oven Fuel Natural gas www.CETontine.org Percent Garage Lighting 100.00 Clothes Dryer Fuel Electric Refrigerator(kWh/yr) 709.00 Clothes Dryer EF 3.01 Dishwasher Energy Factor 0.00 Ceiling Fan (cfm/Watt) 0.00 REM/Rate-Residential Energy Analysis and Rating Software v14.5 This information does not constitute any warranty of energy cost or savings. ©1985-2014 Architectural Energy Corporation, Boulder, Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. Air Leakage Property Organization HERS 91 Emerson Way Center for EcoTechnology Confirmed Northampton, MA 01062 413.586-7350 7/21/14 John Saveson Rating No:13-426 Weather:Northampton,MA Rater IDA911963 91 Emerson Way Builder 13-426 91 Emerson Way Benchmark Custom Homes Northampton final.big Whole House Infiltration j Blower Door Test Heating Cooling Natural ACH j 0.081 0.06 ACH @ 50 Pascals 1.14 1.14 CFM @ 25 Pascals 373 373 CFM @ 50 Pascals 585 585 Eff. Leakage Area(sq.in) 32.1 32.1 Specific Leakage Area 0.00009 0.00009 ELA/100 sf shell (sq.in) 0.42 0.42 Duct Leakage Leakage to Outside Units heatine B cooling CFM @ 25 Pascals 0 CFM25 / CFMfan 0.0000 CFM25 /CFA 0.0000 CFM per Std 152 N/A CFM per Std 152 /CFA N/A I CFM @ 50 Pascals 0 Eff. Leakage Area(sq.in) 0.00 Thermal Efficiency N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage 0.0910 Ventilation Mechanical Exhaust Only Sensible Recovery Eff. (%) 0.0 Total Recovery Eff. (%) 0.0 Rate(cfm) 68 Hours/Day 24.0 Fan Watts 8.7 Cooling Ventilation Natural Ventilation ASHRAE 62.2 - 2010 Ventilation Requirements For this home to comply with ASHRAE Standard 62.2-2010 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings, a minimum of 62 cfm of mechanical ventilation must be provided continuously, 24 hours per day. Alternatively, an intermittently operating mechanical ventilation system may be used if the ventilation rate is adjusted accordingly. For example, a 125 cfm mechanical ventilation system would need to operate 12 hours per day, as long as the system operates to provide required average ventilation once each hour. REM/Rate-Residential Energy Analysis and Rating Software v14.5 This information does not constitute any warranty of energy cost or savings. 0 1985-2014 Architectural Energy Corporation, Boulder, Colorado.