Loading...
41-016 (9) r ©l Air Leakage Property Organization HERS Fierst Center for EcoTechnology Confirmed 1253 Westhampton Rd Unit 2 413-586-7350 8/13/14 Northampton,MA 01062 John Saveson Rating No:14-061 RaterID:1911963 Weather:Northampton,MA Builder 1253 Westhampton Rd Unit 2 Teagno Construction, Inc. 14-061 1253 Westhampton Rd Unit 2 Northampton final.blg Whole House Infiltration Blower Door Test Heating Cooling Natural ACH 0.22 0.16 ACH @ 50 Pascals 3.64 3.64 CFM @ 25 Pascals 255 255 CFM @ 50 Pascals 400 400 Eff. Leakage Area(sq.in) 22.0 22.0 Specific Leakage Area 0.00022 0.00022 ELA/100 sf shell(sq.in) 0.90 0.90 Duct Leakage Leakage to outside Units minisplit CFM @ 25 Pascals 0 CFM25 / CFMfan 0.0000 CFM25 /CFA 0.0000 CFM per Std 152 N/A CFM per Std 152/CFA N/A CFM C 50 Pascals 0 Eff. Leakage Area(sq.in) 0.00 Thermal Efficiency N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage 0.0000 Ventilation Mechanical Exhaust Only Sensible Recovery Eff. (%) 0.0 Total Recovery Eff. (%) 0.0 Rate (cfm) 78 Hours/Day 6.8 Fan Watts 32.6 Cooling Ventilation Natural Ventilation ASHRAE 62.2 - 2010 Ventilation Requirements For this home to comply with ASHRAE Standard 62.2-2010 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings,a minimum of 22 cfm of mechanical ventilation must be provided continuously, 24 hours per day. Alternatively, an intermittently operating mechanical ventilation system may be used if the ventilation rate is adjusted accordingly. For example, a 44 cfm mechanical ventilation system would need to operate 12 hours per day, as long as the system operates to provide required average ventilation once each hour. REM/Rate- Residential Energy Analysis and Rating Software 04.5.1 This information does not constitute any warranty of energy cost or savings. ®1985-2014 Architectural Energy Corporation, Boulder, Colorado. Home Energy Rating Certificate RaRegistry ID ting 14-061021 Rating Number 14-061 Certified Energy Rater John Saveson 1253 Westhampton Rd Unit 2 Rating Date 8/13/14 Northampton , MA 01062 Rating Ordered For Fierst Estimated Annual Energy Cost yr Use MMBtu Cost Percent 5 Stars Plus Heating 8.1 $378 28% Confirmed HERS Index: 64 Cooling 1.1 $54 4% Hot Water 8.0 $377 28% Lights/Appliances 11.9 $560 41% General Information Photovoltaics -0.0 $.0 -0% Conditioned Area 704 sq. ft. House Type Single-family detached Service Charges $0 0% Conditioned Volume 6591 cubic ft. Foundation More than one type Total 29.1 $1369 100% Bedrooms 1 Criteria Mechanical Systems Features This home meets or exceeds the minimum criteria for the following: Air-source heat pump: Electric, Htg: 11.0 HSPF. Clg: 20.3 SEER. Heating: Electric baseboard or radiant, Electric, 100.0%EFF. Heating: Electric baseboard or radiant, Electric, 100.0%EFF. Duct Leakage to Outside 0.00 CFM25. Ventilation System Exhaust Only: 78 cfm, 32.6 watts. Programmable Thermostat Heat=Yes; Cool=Yes Building Shelt Features Ceiling Flat NA Slab R-10.0 Edge, R-40.0 Under Sealed Attic NA Exposed Floor R-30.5 Vaulted Ceiling R-30.5 Window Type U-Value: 0.360, SHGC: 0.450 Green Home Services Above Grade Walls R-36.0 Infiltration Rate Htg: 400 Clg:400 CFM50 Center for EcoTechnology Q Foundation Walls R-20.0 Method Blower door test 320 Riverside Drive, Suite 1A Lights and Appliance Features Florence,MA 01062 413-586-7350 Percent Interior Lighting 100.00 Range/Oven Fuel Electric 413-586-7351 Percent Garage Lighting 100.00 Clothes Dryer Fuel Electric Refrigerator(kWh/yr) 655.00 Clothes Dryer EF 3.01 Dishwasher Energy Factor 0.46 Ceiling Fan (cfm/Watt) 0.00 REM/Rate- Residential Energy Analysis and Rating Software v14.5.1 This information does not constitute any warranty of energy cost or savings. ®1985-2014 Architectural Energy Corporation, Boulder, Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. 1251 WE STHAM PTON RD BP-2013-12555 G,IS COMMO-1 vVEALTH OF MASSACHUSETTS '1 4"ITY OF NORTHAMPTON N�Iip.nk joc : 4! -0 16 Lo-,:-001 Building w"UIL ' EvG PERMIT -l"A BARN -Permit# BP-2013-1255 Project# JS-2013-002010 Est. Cost: $32000.00 Fee: $192.00 PER.11ISSION.IS HEREBY GRANTED TO: Const. Class: U Se Groff-- TEAGNO CONSTRUCTION INC. 034716 'lot Size(sq. ft.): 2147508.00 Owner: FIERS3I FREDERICK U & EVA C 4 �N T'F I . %-, — -r"AG"O CCi,"3 -�bCfQN iN:- Z�OpUCL�Zil ': ' Ez. 1*4 -- ----- - - AT.- 1253 WESTHAMPTON RD Meant Address: Phone: Insurance: 228 TRIANGLE ST (413) 549-0803 Workers Compensat,oi-i SuNIHERSTMA01002 ISSUED ON.71812013 0:00:00 TO PERFORM THE FOLLOWING WORD• CONSTRUCT 32 X 30 BARN INGL. U i 0%,=90N LETTER NOT TO BE USED AS LIVING UNIT SLEEPING SPACE RECORDED PRIOR TO FINAL INSPECTION POST THIS CARD SO IT IS VISIBLE FROM THE STREET nl5pector of Plumbing Ii ector of Wiring D.P.W. Building Inspector fa Underground- Service. Meter: hough: Footings: Rough: R House# Foundation: 0 Driveway Final: 7 final: Final: ,19 Rough Frame: y Fire Department FireplaCY9 innney: Oil: Insulation: Final: Smoke: Final: THIS PER-MIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND RE PION Certificate of Occupancy I Signature: D-atc 1112id: Amount: 2Uildi'IL- 7/8/2013 0:00:00 $192.00 212 Main Street, Phone(4 13)587-1240. Fax: (4!3)587-1272 Louis Hasbrouck- ffilildill- C01111-.IiSSiOner