10D-020 (2) Intrepid 11 Woodburning Stove
Intrepid 11 Clearance Diagrams
See the chart on Page 14 for dimensions indicated by letter in the diagrams below.
Unprotected Surfaces Protected Surfaces
Stove Installed Stove in Stove Installed Stove in
Parallel to Wall Corner Parallel to Wall Corner
Top Exit Installations, no heat shields
JF
B C E F
♦ A (�- ♦ C I♦ ♦ D ♦ ♦ F
Top Exit Installations, rear heat shield, and chimney connector heat shields or double-wall connector
jr/ I& 1 7/
F-8
H I 77A
L
♦
F- , - ♦ I ♦ ♦ L(�4-
Rear Exit Installations, rear heat shields.
N Q
1+ N/A + NIA
ST507
2000966 15
Intrepid'11 Woodburning Stove
Intrepid 11 Clearance Chart
See Pages 15 and 16 for illustrations of these clearances.
Unprotected Surfaces Protected Surfaces
Stove Clearance
Stove Installed Stove in Stove Installed Stove in
Parallel to Wall Corner Parallel to Wall Corner
Side Rear Corners Side Rear Corners
No stove heat shields (A) 24° (B) 30" (C) 20° (D) 12" (E) 16" (F) 10"
610 mm 762 mm 508 mm 305 mm 406 mm 254 mm
Top exit, rear stove h.s.,
single-wall chimney (G) 24" (H) 16" (1) 12" (J) 12" (K) 9" (L) 10"
connector with connector (610 mm) (406 mm) (305 mm) (305 mm) (229 mm) (254 mm)
heat shields'2
Rear exit, rear stove (M) 24" (N) 14" n/a (P) 12" (Q) 9" n/a
heat shield' 610 mm 356 mm 305 mm 229 mm
Top exit, rear stove h.s., (G) 24" (H) 16" (1) 12"
double-wall (610 mm) 406 mm) (305 mm)
chimney connector'
Chimney Connector Clearance
Single-wall chimney
connector, no 26" (660 mm) 12" (305 mm)
connector heat shields
Single-wall chimney
connector, with 10" (254 mm) 5" (127 mm)4
connector heat shields
Double-wall 12" (305 mm)
connector'
Front Clearance to Combustibles
All Installations 48" (1219 mm)
Clearances with double-wall connectors and protected surfaces have not been tested for the Intrepid IL
1. Shielding for a top exit stove must include the stove rear heat shield insert to protect the area behind the flue collar.
2. Chimney connector heat shields, in an installation that goes through a combustible ceiling, must extend to 1" (25 mm)below
the ceiling heat shield,which is 22" (559 mm)in diameter. The ceiling heat shield should be 24 gauge or heavier sheet metal,
centered on the chimney connector, and mounted on noncombustible spacers.
3. Rear exit—horizontal from flue collar directly back through wall.
4. The ceiling heat shield required when chimney connector shields are used should meet the wall protector. This will require trim-
ming the ceiling shield along the line of intersection with the wall protector.
5. In top exit installations, this clearance requires the use of the rear heat shield with the shield insert installed.
14 2000966
Intrepid"11 Woodburning Stove
Protection In Canada,the floor protector required under the stove must
Floor extend 18" (460 mm) to the front(labeled 'E', Fig. 11), and
A tremendous amount of heat radiates from the bottom 8" (203 mm)from the sides and rear. ('D' ,Fig. 11)
plate of an Intrepid II, and the floor beneath requires two To meet Canadian requirements, a floor protector must be
kinds of special protection. at least 38" (965 mm)wide and 44" (1118 mm) deep.
Heat protection is provided by a Bottom Heat Shield, part Floor protection also must extend under the chimney con-
#0307. nector and 2" (51 mm)to either side. ('C', Fig. 11) For 6"
Spark and ember protection is provided by a floor protector, (152 mm)connector used with the Intrepid II,the protector
which may be any noncombustible material. must be a minimum of 10"(254 mm)wide, centered under
For a new hearth, we recommend a noncombustible floor the connector.
protector such as 1/4" non-asbestos mineral board or its Floor Protection f. Fireplace Installations
equivalent,or 24 gauge sheet metal. If carpeting is present,
it must be removed before installation of the floor protector. Do not assume your fireplace hearth is completely non-
The floor protector may be covered with a noncombustible combustible.
decorative material if desired. When using brick, tile, or Many fireplace hearths do not satisfy the"completely non-
stone, individual pieces must be mortared so sparks can- combustible"requirement because the brick or concrete in
not fall through. front of the fireplace opening is supported by heavy wood
Most installations will require that the bottom heat framing as in Figure 12.Because heat passes through brick
shield be attached. Only when the stove is placed on or concrete readily, it can easily pass through to the wood.
a completely noncombustible surface, such as un- As a result,such fireplace hearths can be a fire hazard and
painted concrete over earth, may it be used without are considered a combustible floor.
the bottom heat shield.
Even with the bottom heat shield installed, you must also
use a floor protector.
In the United States,the floor protector required under the
stove must extend at least 16" from the front of the stove
-not from the ashlip-(Labeled 'E in Fig. 11), and at least 71 47
6" from the sides and rear('D', Fig. 11).
To meet the requirement in the United States, a floor pro-
tector must be at least 34"wide and 40" deep. , ME
c >� Wood framing requires
Top Exit Rear Exit protection from radiant heat ST247a
�. Fig. 12 Supporting timbers under fireplace hearth are consid-
° o ered to be combustible.
Y
.........._....: a
Keep in mind that many raised hearths will extend less than
°y! �i l the required clearance from the front of the heater when
I` ° ` ° °' it is installed. In such cases, sufficient floor protection as
- - - -- described above must be added in front of the hearth to
E E satisfy the minimum floor protector requirement from the
+-... front of the stove: 18" (460mm)from the front in Canada.
t A — 'I �` " Fireplace hearths must also offer the required protection
U.S. Canada of 8" (203 mm) on either side.
A. 34" 38" (965 mm) Optional 37' (76 mm)short legs may be used only on such
B. 40" 44" (1118 mm) hearths that meet the width and depth requirements out-
C. 10" 10" (254 mm) lined previously under"floor protection."
D. 6" 8" (203 mm)
E. 16" 18" (457 mm) sTSOO Hearth rugs do not satisfy the requirements for floor pro-
tection.
Fig. 11 Required floor protector dimensions. Fireplace installations also have special clearance require-
ments to the side walls, side decorative trim, and fireplace
mantle. Refer to the information on fireplace and mantel
trim shields in this section.
10 2000966
-TAe Commonwealth of Massachusetis
Department of Industrial Accidents
Office of Investigations
I Congress Street,Suite 100
Boston,MA 02114-2017
www.mass gov/dia
Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers
Applicant Information Please Print Leaiblv
Name (Business/OrganizationAndividutal): BERNARDSTON FARMERS SUPPLY
Address:43 RIVER STREET
City/State/Zip:BERNARDSTON,MA 01337 Phone#:413-648-9311
Are you an employer?Check the appropriate box: Type of project(required):
1.FEI I am a employer with
4. I am a general contractor and t
employees(full and/or part-time).* hired the sub-contractors 6. E]New construction
2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling
ship and have no employees These sub-contractors have 8. ❑Demolition
working for me in any capacity. employees and have workers' 9 ❑ Building addition
[No workers' comp. insurance comp.insurance.*
required.] 5. ❑ We are a corporation and its 10.❑Electrical repairs or additions
3.❑ I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions
myself. [No workers' comp. right of exemption per MGL 12.❑Roof repairs
insurance required.]t c. 152,§1(4),and we have no
employees. [No workers' 13.❑Other
comp.insurance required.]
*Any applicant that checks box#t must also fill out the section below showing their workers'compensation policy information.
t Flomeowners%ho submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such.
*Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have
employees. If the sub-contractors have employees,they must provide their workers'comp.policy number.
fain an employer that is providing workers'compensation htstirance for tnv employees. Below is the policy and job site
information.
Insurance Company Name:PEERLESS INSURANCE
Policy#or Self-ins. Lic.#:WC8165644 Expiration Date:7/1/14
Job Site Address:
143 /'Yl e?>✓ (34 City/State/Zip: L r'� ,>3 G' f� cr'/05 j
Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date).
Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a
fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine
of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of
Investigations of the DIA for insurance coverage verification.
I do hereby certo nder the pains and p allies ofperjury that the information provided above is true and correct.
44�� Er
Signature: ( � � c� -- Date: cf
Phone#: q/_3 �3- Y
Official use on/11. Do not write in this area,to be completed by city or town official.
City or Town: Permit/License#
Issuing Authority(circle one):
1. Board of Health 2. Building Department 3.City/Town Clerk 4. Electrical Inspector 5.Plumbing Inspector
6.Other
Contact Person: Phone#:
of Northampton _
�`` �- c
Massachusetts
s - 12014G
!y'_
1]Ep OF BUILDING ZISrSPE'CTIOM
n �21 Street • Municipal Building�•�-s `���
!c lectric Piumbine S G o ton, MA 01060 h _
�;yxw:K�ik4n� �'�
N'fJi1
OINOU OR TWO GAMILY sm-in FUEL APPLIANCE PERMIT APPLICATION
FOR WOOD, COAL, PELLET, CORN, STRAW OR SIMILAR STOVES, OR FIREPLACE INSERTS
Permit Fee: $25.00 Check#—'r?
�0
-�-- �-PLEASE TYPE OR PRINT ALL INFORMATION
1. Name of Applica nt �T Ld�►�f��S L �a� r' '
Address: %J- /� a 147-Q Telephone- �-3
`�/� �
/� 'id O %
2_ Owner of Property: ,� S d l� d N
Address:
i� 171nl'W °3 L��E'►�� 8"�1#� Telephone:
3. Status of Applicant Owner Contractor
4_ Type or Brand of Stove:
If applicant is not the homeowner:
Construction Supervisor's License Number Expiration Date
Home Improvement Contractor Registration Number -5-,�R Expiration Date -';?2-4
All Applicants must complete a Workers Compensation Insurance Affidavit before we can issue a permit
5. Certification.l hereby certify that the information contained herein is true and accurate to the best
of my knowledge.
DATE: 7 l APPLICANT'S SIGNATURE ^
DATE: v"' ' HOMEOWNER'S SIGNATURE
APPROVED
DATE: BUILDING OFFICIAL
163 MAIN ST BP-2015-0013
GIs#: COMMONWEALTH OF MASSACHUSETTS
Map:Block: IOD-020 CITY OF NORTHAMPTON
Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
Category: woodstove BUILDING PERMIT
Permit# BP-2015-0013
Project# JS-2015-000019
Est.Cost:
Fee: $25.00 PERMISSION IS HEREBY GRANTED TO:
Const. Class: Contractor: License:
Use Group: BERNARDSTON FARMERS SUPPLY 99401
Lot Size(sq. ft.): 35719.20 Owner: JOHNSON JASON L&ERIN M MAHON-MOORE
Zoning:URB(104)/WP(40)/ Applicant. BERNARDSTON FARMERS SUPPLY
AT.• 163 MAIN ST
Applicant Address: Phone: Insurance:
43 RIVER ST (413) 648-9311 O WC
BERNARDSTONMA01337 ISSUED ON.71212014 0:00:00
TO PERFORM THE FOLLOWING WORK.-INSTALL INTREPID WOODSTOVE
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter:
Footings:
Rough: Rough: House# Foundation:
Driveway Final:
Final: Final:
Rough Frame:
Gas: Fire Department Fireplace/Chimney:
Rough: Oil: Insulation:
Final: Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Certificate of Occupancy Signature:
FeeType: Date Paid: Amount:
Building 7/2/2014 0:00:00 $25.00
212 Main Street,Phone(413)587-1240,Fax: (413)587-1272
Louis Hasbrouck—Building Commissioner