15B-049 (6) ® 1 The Right Way! Installation Instructions The S-5!(D Mini clamps are made for a variety of standing seam profiles.When attaching to machine folded seams (regardless of panel profile and geometry), S-5!®clamps are designed to engage the seam as shown. f 414-A On many snap-together type seams. the setscrew is opposite the open (or overlap) side of the seam. On some seams, this aspect of clamp orientation is not critical. Install with a screw gun and included screw gun bit tip. For optimal holding strength, screw tension should be 160 to 180 inch pounds on 22ga steel and 130 to 150 inch pounds for all other metals • and thinner gauges of steel. S-5!® Warning! Please use these products responsibly! Visit our website or contact your S-5!® •J distributor for detailed installation instructions and load test results.The user and/or the installer of these parts is responsible for all necessary engineering and design for the intended use of these C7 parts in an assembly or application. Copyright 2010,Metal Roof Innovations,Ltd.S-5!c products are patented by Metal Roof Innovations,Ltd. y n Version 031510 Attach almost anything to standing seam metal roofs 888-825-3432 WWW.S-5.COm without piercing the panel! ® 1 S59 The Right Way! 7;e, Installation Instructions The S-5-U, S-5-S, S-5-E and S-5-13 clamps are made for typical standing seam profiles. When attaching to machine folded seams (regardless of panel profile and geometry). S-5!(5 clamps are designed to engage the seam as shown. For horizontal seam applications, the setscrews must be accessible from the top for tightening. On many snap-together type seams, the setscrews are opposite the open (or overlap) side of the seam. On some seams, this aspect of clamp orientation is not critical. The S-5-U has four setscrew locations to make the clamp more versatile, however, only two setscrews are used per clamp. The setscrews should always be placed on the same side of the clamp. Determine how to position the clamp, and for the S-5-U, which side of the clamp to load the setscrews into. For maximum holding strength, setscrews should be tensioned and re-tensioned as the seam material compresses. When relying on tested values, screw tension should be verified using a calibrated torque wrench between 160 and 180 inch pounds when used on 22ga steel and between 130 and 150 inch pounds for all other metals and thinner gauges of steel. Consult the S-5!@ website at www.S-5.com for published data regarding holding strength. S-5!® Warning! Please use these products responsibly! Visit our website or contact your S-5!® distributor for detailed installation instructions and load test results. The user and/or the installer of , these parts is responsible for all necessary engineering and design for the intended use of these parts in an assembly or application. Copyright 2010,Metal Roof Innovations,Ltd.S-5.!CD products are patented by Metal Roof Innovations,Ltd. ,++' i' • Attach almost anything to standing seam metal roofs 888-825-3432 WWW.S-5XOM without_,piercing the panel 4 The strength of the S-6-U clamp is in its simple design. The patented setscrews will slightly dimple the metal seam material but not pierce it— roof warranties intact. The Right Way! The S-5-U and S-5-11,11 Mini clamps are each furnished with the hardware shown to the right.Each box also includes a bit tip for tightening setscrews using an electric screw nn10 hole gun.A structural aluminum attachment clamp,the S-5-U 2.00" located 1n°(13.00 mm) from edge of part is compatible with most common metal roofing materials (51.00 mm) , excluding copper.All included hardware is stainless // steel.Please visit www.S-5.com for more information including CAD details,metallurgical compatibilities and specifications. The S-5-U clamp has been tested for load-to-failure results (38.00 mm) on most major brands and profiles of standing seam roofing. The independent lab test data found at 0.54" www.S-5.com can be used for load-critical designs and 0.901, (23. ) 00 mm applications.S-5!1 holding strength is unmatched in the ` industry. ���� �fa' t` - ,, ��_ W ✓�1 Note:Install both 0.40" � � ���jl����� setscrews onsame (10.00 mm) side of clamp. S (38.00 mm) l ' M8 hales centered 1.18" on part I (30.00 mm) / 7 1.50" (38.00 mm) 0.90" For horizontal seams under 0.65"do not use this clamp.Visit (23.00 m ) (14, tl rrt www.S-5.com for more detailed information and proper _ if clamp to use. /llrT i -__ 0.40., (10.00 mm) 1.50.1 ► (38.00 mm) Please note:All measurements are rounded to the second decimal place. 5-5!"Warning!Please use this product responsibly! Distributed by Products are protected by multiple U.S.and foreign patents.Visit the website at www.S-5.com for complete information on patents and trademarks.For maximum holding strength,setscrews should be tensioned and re tensioned as the seam material compresses.Clamp setscrew tension should be verified using a calibrated torque wrench between 160 and 180 inch pounds when used on 22ga steel, and between 130 and 150 inch pounds for all other metals and thinner gauges of steel.Consult the S-5! website at www.S-5.com for published data regarding holding strength. Q,pyright1013,Me!alRoo(Innovations,LidS-5!productsarepatentedlr lected. S-S aggressively protects ill patents,uar—ml,s and capyrlghts.Version 031113. ■ .C� G LO The Right Way! M S-5-U Clamp The S-5-U clamp is by far our most LO popular and most versatile clamp. It fits about 85%of the standing seam profiles manufactured in North ` America—including most structural and architectural profiles. It can be used on vertically oriented seams and, by rotating the clamp 90 degrees, it can also be used C on most horizontal 2"seam profiles. i Its simple design,generous dimensioning OR and multiple hole orientations are what make the S-5-U clamp so versatile for use with the S-5!1 snow retention products, such as ColorGard°,as well as with other heavy-duty applications. } Installation is as simple as setting the specially patented round-point setscrews V into the clamp,placing the clamp on 'f the seam,and tightening them to the specified tension.Then,affix ancillary items using the bolt provided with the product. Go to www.S-5.com/tools for information and tools available for 0 properly attaching and tensioning S-51 "" • clamps. (��h�� C S-5-U Mini Clamp • The 5-5-U Mini is a bit shorter than the �. S-5-U and has one setscrew rather than two.The mini is the choice for attaching ; y" 6 all kinds of rooftop accessories:signs, walkways,satellite dishes,antennas, N rooftop lighting, lightning protection M systems,solar arrays,exhaust stack WN bracing,conduit,condensate lines, 0Io of Lhmechanical equipment—just about ;m an thin I* -- ; I ��Sam profiles y g in North America. CO �r *S-5!mini clamps are not compatible with,and should not rir be used with S-5!SnoRail—/SnoFence"or ColorGard@ snow WMM retention systems. W CS6 -/35/240! 245 250 l 55P Electrical Data STC CS6P-235P CS6P-240P CS6P-245P CS6P-250P CS6P-255P Nominal Maximum Power (Pmax) 235W 240W 245W 25OW 255W Temperature Characteristics Optimum Operating Voltage(Vmp) 29.8V 29.9V 30.OV 30.1V 30.2V Pmax -0.43%11C Optimum Operating Current(Imp) 7.90A 8.03A 8.17A 8.30A 8.30A Temperature Coefficient Voc -0.34%/ Open Circuit Voltage(Voc) 36.9V 37.OV 37.1V 37.2V 37AV Isc 0.065%/'C Short Circuit Current(Isc) 8.46A 8.59A 8.74A 8.87A 9.00A Normal Operating Cell Temperature 45±2'C Module Efficiency 14.61% 14.92% 15.23% 15.54% 15.85% Operating Temperature -40'C-+85'C Performance at Low Irradiance Maximum System Voltage 1000V(IEC)/600V(UL) Industry leading performance at low irradiation Maximum Series Fuse Rating 15A environment,+95.5%module efficiency from an Application Classification Class A irradiance of 1000w/m'to 200w/m' Power Tolerance 0-+5W (AM 1.5,25°C) Under Standard Test Conditions(STC)of irradiance of 1000WIm',spectrum AM 1.5 and cell temperature of 25'C Engineering Drawings NOCT CS6P-235P CS6P-240P CS6P-245P CS6P-250P CS6P-255P Nominal Maximum Power (Pmax) 170W 174W 178W 181W 185W Optimum Operating Voltage(Vmp) 27.2V 27.3V 27AV 27.5V 27.5V Optimum Operating Current(Imp) 6.27A 6.38A 6.49A 6.60A 6.71A j 1 Open Circuit Voltage(Voc) 33.9V 34.OV 34.1 V 34.2V 34AV Short Circuit Current(Isc) 6.86A 6.96A 7.08A 7.19A 7.29A I 1 I Under Normal Operating Cell Temperature.Irradiance of 800 W/m',spectrum AM 1.5,ambient temperature 20°C, wind speed 1 mis Mechanical Data Cell Type Poly-crystalline 156 x 156mm,2 or 3 Busbars Cell Arrangement 60(6 x 10) Dimensions 1638 x 982 x 40mm(64.5 x 38.7 x 1.57in) Weight 19kg(41.9lbs) Front Cover 3.2mm Tempered glass Frame Material Anodized aluminium alloy J-BOX IP65,3 diodes j Cable 4mm'(IEC)/12AWG(UL),1000mm 982 Connectors MC4 or MC4 Comparable TF Standard Packaging(Modules per Pallet) 24pcs Module Pieces per container(40ft.Container) 672pcs(40'HQ) I IN Curves (CS6P-255P) i i ..w. -._......_. .. :MI .,r. S-h—A-A I 35.0. 3 I 1 � o E O "Specifications included In this datasheet are subject to change without prior notice. About Canadian Solar Canadian Solar Inc. is one of the world's largest solar Canadian Solar was founded in Canada in 2001 and was companies. As a leading vertically-integrated successfully listed on NASDAQ Exchange (symbol: CSIQ) in manufacturer of ingots,wafers,cells,solar modules and November 2006. Canadian Solar has module manufacturing solar systems, Canadian Solar delivers solar power capacity of 2.05GW and cell manufacturing capacity of 1.3GW. products of uncompromising quality to worldwide customers. Canadian Solar's world class team of professionals works closely with our customers to provide them with solutions for all their solar needs. Headquarters .; Guelph I Ontario Ni K I E6 I Canada Tel:+1 519 837 1881 . . www,canadiansolar,com EN-Rev 10.16 Copyright"2012 Canadian Solar Inc. 4 Main electric panel Ml located in basement "Sn r s Daniel Melnik 259 Chesterfield Rd . Leeds Ma 01053 No theast Northeast 136 Elm St. Hatfield, Ma. 01038 413-247-6045 June 2, 2014 Re: Building Permit for 259 Chesterfield Rd. Leeds, Ma 01053 To the Building Inspector: The roof structure at 259 Chesterfield Rd. Leeds, Ma 01053 is constructed of 2x12" SPF#2 rafters @ 16" on center, a maximum span of 13' 3" with a 10/12 pitch.The sheathing is 1/2" plywood and there is one layer of asphalt shingles covering the roof surface. Based on the 8th edition of the International Building Code, and the Ground Snow Load of 40 psf,the roof structure is strong enough to support the additional 3psf of the proposed photovoltaic modules and racking.The photovoltaic modules' rail attachment points will be in a staggered pattern with rail mounting feet no more than 4'on center to most evenly distribute the weight of the photovoltaic array. cer , Phillip Baunsgard Jr. MA-CSL#CS-106113 Installation Supervisor Northeast Solar Design (413)247-6045 136 Elm St. Hatfield, Ma 01038 The Commonwealth of Massachusetts Print Form Department of Industrial Accidents Office of Investigations I Congress Street, Suite 100 Boston, MA 02114-2017 'ter www.mass.gov/dia Workers' Compensation Insurance Affidavit: General Businesses Applicant Information Please Print Legibly Business/Organization Name:Northeast Solar Address:136 Elm St. City/State/Zip:Hatfield, Ma 01038 Phone #:413-247-6045 Are you an employer? Check the appropriate box: Business Type(required): 1.❑✓ I am a employer with 10 employees (full and/ 5. ❑ Retail or part-time).* 1 6. ❑ Restaurant/Bar/Eating Establishment 2.❑ i am a sole proprietor or partnership and have no 7, ❑ Office and/or Sales(incl. real estate, auto, etc.) employees working for me in any capacity. [No workers' comp. insurance required] 8• ❑ Non-profit 3.❑ We are a corporation and its officers have exercised 9. ❑ Entertainment their right of exemption per c. 152, §1(4), and we have 10.❑ Manufacturing no employees. [No workers' comp. insurance required]* 11.0 Health Care 4.❑ We are a non-profit organization, staffed by volunteers, with no employees. [No workers' comp. insurance req.] 1 12.0 Other *Any applicant that checks box#1 must also till out the section below showing their workers'compensation policy information. **If the corporate officers have exempted themselves,but the corporation has other employees,a workers'compensation policy is required and such an organization should check box#1. I ant an emplover that is providing workers'compensation insurance for my employees. Below is the policv information. Insurance Company Name:Hanover Insurer's Address:259 Chesterfield Rd. City/State/Zip: Leeds, Ma 01053 Policy # or Self-ins. Lic. #WHN 5715134-02 Expiration Date:4/8/15 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of investigations of the DIA for insur coverage verification. I do herebv ce ' V, under at and penaltie perjury that the information provided above is true and correct. Signature Date: Phone#:413-247-6 Of use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority (circle one): 1. Board of Health 2. Building Department 3. City/Town Clerk 4. Licensing Board 5. Selectmen's Office 6. Other Contact Person: Phone#: www.mass.gov/dia SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder: Phillip Baunsgard C S 10 6113 License Number 11 Edward Ave. Southampton, Ma 01073 6/7/15 Address Expiration Date 413-247-6045 Signature Telephone 9.Registered Home Improvement Contractor: Not Applicable ❑ Northeast Solar 169641 Company Name Registration Number 136 Elm St . Hatfield, Ma 01038 7/14/15 Address Expiration Date Telephone 413--247-6045 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application.Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes........0 No...... ❑ 11. - Home owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780. Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. I Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. j Also be advised that with reference to Chapter 152(Workers'Cgmpensation) and Chapter 153(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may liable for person(s) { you hire to perform work for you under this permit. The undersigned"hotneowner"certifies and assumes responsibility for compliance with the State Building Code,City of { Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature i I I i 3 I i SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House Addition [] Replacement Windows Alteration(s) ❑ Roofing Or Doors 0 Accessory Bldg. ❑ Demolition ❑ New Signs [Cl] Decks IM Siding[O] Other[[R7 Brief Description of Proposed Work; Install 25 solar pancls nn the mor Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet Ba'If New house and or addition to existing housing, complete the following: a. Use of building:One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? r. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No J, Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. i. Septic Tank City Sewer_ Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Daniel Melnik as Owner of the subject property r i hereby authorize /L 1,4r '" to act on beh in matters relative to work author' y this building permit application. 6-3-14 i Signature of Owner L7 Date Ann Bronner Northeast Solar as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Ann Bronner Print Name 6-3-14 Signature of Owner/Agent Date I i Section 4. ZONING All Information Must Be Completed.Permit Can Be Denied Due To Incomplete Informatfort Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Rear Y111 Building Height Bldg.Square Footage Open Space Footage 7 (Lot area initins bldg&paved A. Has a Special Permit/Variance/Find ever been issued forlon the site? NO DON'T KNOW I@r YES { ) - - - - IF YES, date iszupd:'|- } IF YES: Was the permit recorded a1 the Registry ofDeeds? NO 0 DONTKNOYV 0 YES r ------- 1 '-- ------\ �'-- ---- -1 IFY[S' enter Book Page;: and/or Dncument# ' / �� �� B. Does the site contain a brook, body of vmLpr or wetlands? NO ��' DON7 KNOW \~� YES \^� IF YES, has permit been or need to bp obtained from the Conservation Commission? Needs tobe /~� Obtained /`� Da�e \xsued�. }------ - - obtained �~/ . C. Do any signs exist on the property? YES NO IF YES, descrbex�e. type �cuUvn� � D Are YES /—� NO D. ' IF YES, describe size, type and location: E. Will the construction activity disturb grading,excavation,mfilling)over 1 acre misnpart ofe common plan that will disturb over 1acre? YES [ > NO ~� IF YES,then a Northampton Storm Water Management Permit from the DPW is required. | Ir— ti Department use only DCity, f Northampton Status of Permit:: SUN 2014 B�a g Department Curb Cut/Driveway Permit 2 Main Street Sewer/Septic-Availability om 100 WaterlWeil Availability ' GA'i"a lam ton, MA 01060 E4ectric, rthall ton.t.1k g Two Sets of Structural Plans NorthamP ne -587-1240 Fax 413-587-1272 PIOUSite Plans Other Specify APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address. This section to be completed by office Map Lot Unit... 2.59 Chesterfield Rd. Zone Overlay District . EIm,St.;District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: �) Daniel Melnik /A"1-A;('f �. ,EL y K 4:-*Chesterfield Rd. Leeds, Ma 01053 Nam rint) Current Mailing Address' p 413-584-6750Northeast Solar 0� _ (I� Telephone Signature 2.2 Authorized A-gent: /�D Northeast S lar Northeast Solar / S�{ ,i<�^1 1T �� � Nai a(frint) Current Mailing Address: mar _7 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)tD be Official Use Only completed by ermit applicant I 1. Building (a)Building Permit Fee 4 i 2, Electrical (b)Estimated Total Cost of Construction from 6 i 3. Plumbing Building Permit Fee_ i I - i 4. Mechanical(HVAC) 5.Fire Protection j 6. Total=0 +2+3+4+5) 24,022 Check Number This Section For Official Use Only Building Permit Number te r: i Issued: I Signature: Building Commissioner/inspector of Buildings Date I I 1 File#BP-2014-1309 APPLICANT/CONTACT PERSON NORTHEAST SOLAR DESIGN ASSOCIATES LLC ADDRESS/PHONE 136 ELM ST HATFIELD (413)247-6045 Q PROPERTY LOCATION 259 CHESTERFIELD RD MAP 15B PARCEL 049 001 ZONE THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid rT Typeof Construction: INSTALL 25 ROOF MOUNTED SOLAR PANELS New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 106113 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFO TION PRESENTED: pproved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Iii' Delay Signa ure of ui ng Of icial Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of Planning& Development for more information. 259 CHESTERFIELD RD BP-2014-1309 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 15B-049 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR PANELS BUILDING PERMIT Permit# BP-2014-1309 Project# JS-2014-002204 Est. Cost: $24022.00 Fee: $144.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: NORTHEAST SOLAR DESIGN ASSOCIATES LLC 106113 Lot Size(sq. ft.): Owner: MELNIK PATRICK J Zoninyz: Applicant: NORTHEAST SOLAR DESIGN ASSOCIATES LLC AT: 259 CHESTERFIELD RD Applicant Address: Phone: Insurance: 136 ELM ST (413) 247-6045 () Workers Compensation HATFIELDMA01038 ISSUED ON.611112014 0:00:00 TO PERFORM THE FOLLOWING WORK.-INSTALL 25 ROOF MOUNTED SOLAR PANELS POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy SiEnature: FeeType: Date Paid: Amount: Building 6/11/2014 0:00:00 $144.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner