30C-052 (6) City of Northampton Mail- 105 Clement Street https://mail.google.com/mail/u/0/?ui=2&i1--3921Iafc3d&view=pt&se... Charles Miller<cmiller @northamptonma.gov> 105 Clement Street 1 message Charles Miller<cmiller @northamptonma.gov> Mon,Jun 2,2014 at 10:07 AM To:John Landry<john @route9designbuild.com> Hi John, Normally I would communicate with the applicant,but since its your plan I figured I'd try you first. Here are a few issues I've found. 1. Cement siding is not intended to be in contact with the ground. 2. Smokes and COs to code throughout the entire structure including a smoke/CO in the studio. 3. Frost protected foundations have maximum and minimum requirements.They must be a minimum of 12"below grade on undisturbed soils.They cannot extent more than 12"above finished grade. Figure R403.3(1) Chuck Miller Assistant Building Commissioner City of Northampton Town of Williamsburg 1 of 1 6/2/2014 10:08 AM /yZ. IM CLEARANCES Install siding and trim products in Maintain a minimum 2" Maintain a minimum 2"clearance At the juncture of the roof and vertical Maintain a 1/4" compliance with local building code clearance between between James Hardie products surfaces,flashing and counterflashing clearance between requirements for clearance between James Hardie® and decking material. shall be installed per the roofing the bottom of James manufacturer's instructions.Provide a Hardie products and the bottom edge of the siding and products and paths, Figure 7 minimum 2"clearance between the horizontal flashing. the adjacent finished grade, steps and driveways. roofing and the bottom edge of the Do not caulk gap. water siding and trim. Refer to fig.3 on stud siding resistive page 1. Figure 5 Figure 6 �► barrier Figure 8 P 9 siding 2"min. deck material t 2"min '� 2" min. t plate joist ledger flashing concrete ."min. I foundation Dc not bridge floors with HardiePanelO siding.Horizontal KICK®UT FLASHING joints should always be created between floors(fig.10). Because of the volume of water that can pour down a sloped Water- roof,one of the most critical flashing details occurs where a Resistive Framing roof intersects a sidewall. The roof must be flashed with step Maintain a minimum 1"gap Barrier between gutter end caps and Figure 10 flashing. Where the roof terminates,install a kickout to deflect siding&trim. Horizontal Flooring water away from the siding.It is best to install a self-adhering Figure 9 Trim membrane on the wall before the subfascia and trim boards are nailed in place,and then come back to install the kickout. Figure 11,Kickout Flashing To prevent water from dumping behind the siding and the end of the roof siding Sheathing intersection,install a"kickout"as required by IRC code )�• 8905,2.8.3:"...flashing shall be a min.of 4"high and 4" •` fascia HardiePanel° wide."James Hardie recommends the kickout be angled between 100°-110°to maximize water deflection gutter and end cap Figure 11 a hers aching BLOCKED PENETRATIONS � . Self-dering��� Penetrations such as hose bibs and holes 1 %z"or larger such as dryer vents membra e shall have a block of trim around point of penetration. e eaves me embr membrane s mane Ktdmut GENERAL FASTENING REQUIREMENTS . flashing 0, Fasteners must be corrosion resistant,galvanized,or stainless steel.Electro-galvanized are < Drip edge acceptable but may exhibit premature corrosion.James Hardie recommends the use of quality, ( ' hot-dipped galvanized nails. James Hardie is not responsible for the corrosion resistance of Housewrap fasteners. Stainless steel fasteners are recommended when installing James Hardie products near the ocean,large bodies of water,or in very humid climates. • Consult applicable product evaluation or listing for correct fastener type and placement to achieve specific design wind loads. PNEUMATIC FASTENING • NOTE:Published wind loads may not be applicable to all areas where Local Building Codes have James Hardie products can be hand nailed or fastened with a specific jurisdiction.Consult James Hardie Technical Services if you are unsure of applicable pneumatic tool.Pneumatic fastening s highly recommended. compliance documentation. g g y • Set air pressure so that the fastener is driven snug with the Drive fasteners perpendicular to siding and framing. • Fastener heads should fit snug against siding(no air space).(fig.A) surface of the siding.A flush mount attachment on the • Do not over-drive nail heads or drive nails at an angle. pneumatic tool is recommended. This will help control the • If nail is countersunk,fill nail hole and add a nail.(fig.B) depth the nail is driven.If setting the nail depth proves difficult, • For wood framing,under driven nails should be hit flush to the plank with a hammer(for steel choose a setting that under drives the nail.(Drive under driven framing,remove and replace nail). nails snug with a smooth faced hammer-Does not apply for • NOTE:Whenever a structural member is present,HardiePlank should be fastened with even installation to steel framing). spacing to the structural member.The tables allowing direct to OSB orplywood should only be used when traditional framing is not available. • Do not use aluminum fasteners,staples,or clipped head nails. Snug Flush Ji® ® Countersunk, 0 li fill&add nail Eli do not under DO NOT Figure A Figure B drive nails STAPLE HS1237-P2/3 8/13 Y4 _ _1�Ci!y1S aS �Cc -(-o C/ rC 6L -S- Y- -ILL Of 6 0 City of Northampton Massachusetts {S�s ':,s��fl 4\ } r DEPARTMENT OF BUILDING INSPECTIONS ?t ' 212 Main Street • Municipal Building Northampton, MA 01060 ssp y�l�fi INSPECTOR Louis Hasbrouck Chuck Miller Building Commissioner Assistant Commissioner HOME OWNER EXEMPTION ACKNOWLEDGEMENT The State of Massachusetts allows the homeowner the right under 780CMR 108.3.4 to act as his/her construction supervisor. The state defines "Homeowner" as, " Person(s) who owns a parcel on which he/she resides or intends to be, a one or two family dwelling, attached or detached structures accessory to such use and/or farm structures. A person who constructs more than one home in a two- year period shall not be considered a home owner." The building department for the City of Northampton wants any person(s)who seek to use the home owner exemption, to act as their own construction supervisor, to be aware that by doing so you become responsible for compliance with state building codes and regulations. The inspection process requires that the building department be called to inspect work at various stages, which include foundation/footings (before backfill), sonotube holes (before pour), a rough building inspection (before work is concealed), insulation inspection (if required) and a final building inspection The building department requires these inspections before the work is concealed, failure to secure these inspections can result in failure to obtain a certificate of occupancy until the work can be inspected. If the homeowner hires other trades to perform work (electrical, plumbing & gas) the homeowner will be responsible to make sure that the trades hired secure their proper permits in conjunction to the building permit issued, and that they get their required inspections. Failure of the individual trades to secure the permits and inspections as required can DELAY the project until such time as the proper permits and inspections are made I, Y-Al-CA understand the above. (Homb owner/resident's signature reque g exemption) I will call to schedule all required building inspections necessary for the building permit issued to me. Date Address of work location / C IP vn p 7L 1—'/ re Ott tlf The Commonwealth of Massachusetts Department of Industrial Accidents { Office of Investigations 600 Washington Street Boston, MA 02111 Y www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information �® Please Print Legibly Name (Business/Organization/Individual): [�k'1ne [)VJ rlt-4 /2 4 d Address: I t.I 6- S4 U_ - UX City/State/Zip: Phone M Are you an employer? Check the appropriate box: Type of project(required): 1.❑ I am a employer with 4. ❑ I am a general contractor and I 6 t�J-New construction employees (full and/or part-time).* have hired the sub-contractors 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g. ❑ Demolition working for me in any capacity. employees and have workers' 9 uilding addition [No workers' comp. insurance comp.insurance.t required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs addit no s I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or itions myself. [No workers' comp. right of exemption per MGL 12.21 Roof rQmi�lyoet V)1L insurance required.] t c. 152, §1(4), and we have no employees. [No workers' 13.El Other �{- ,�r.c t: comp. insurance required.] AVA *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. tHo meowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. $Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: — Policy#or Self-ins.Lic. #: Expiration Date: Job Site Address: City/State/Zip: Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and pen ties of perjury that the information provided above is true and correct. Signature: �—' C.. Date: Phone# �� , (U — s 77 Official use only. Do not write in this area, to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3. City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6. Other Contact Person: Phone#: SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable £ Name of License Holder: License Number Address Expiration Date Signature elephone 9.Regisferetl Home.lmnrovemert"Conf�actor Not Applicable £ Company Name Registration Number Address Expiration Date Telephone SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... £ No...... £ OyVYL(� �►� I'M`eri c b� � �^ 11. ':Home Owner Exerription The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) r r New House ❑ Addition Replacement Windows Alteration(s) Roofing )�Z71 Or Doors Accessory Bldg. ❑ Demolition ❑ New Signs [O] Decks [M Sidin k Other[[Ij 11 Brief Description of toposed 5 r Work: Of' W S K C Alteratio 'sting bedroom - Yes No Adding new bedroom Y� Yes No At Fa ch rrative Renovating unfinished basement Yes �_No �°%Y f�S ans Attac a oil -Shee e and , sa:lf New'hous` or addition to�existing housing,complete the following: a. Use of building:One Family _ Two Familily��. p Other b. Number of rooms in each family unit: 19 (A)" Number of athrooa(v"%ms frL°Y��y� a tA) �� ��✓1 c. Is there a garage attached?_j 5 �. � �* 5�, �f. oeOki Cfn'e c tom/ U d. Proposed Square footage of new construction.3 3 bo Dimensions ItPX`7�rrlu ) 1 f Le v e. Number of stories? -I ,C M t,tV,c�tt7,�Q�' �cd�roc�m r �},S�bca�.'. Gi/c�ul'►`'1 f"Faf/ f. Method of heating?1"�u��tXlyyt_ F��r Fireplaces or Woodstoves © Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction6fandard �'t�i►'r ( /��c b�''l i. Is construction within 100 ft. of wetlands? Yes > No. Is construction within 100 yr.nnfloodplain Yes No j. Depth of basement or cellar floor below finished grade tXi 5fi�� L1ll ve- F Id �S w^ �;v" k. Will building conform to the Building and Zoning regulations? >4'_—Yes No. I. Septic Tank City Sewer_ Private well City water Supply _ SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT sC ( P as Owner of the subject property hereby authorize f to act on my behalf, in all matters r6lative to work authorized by this building-Kermit application. W_ J "7 � — Sign ure of Owner Date (a �C.��QC�tC; as Owner/Authorized Agent her by declare that the statements and infdrmation on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury, Print Nanfe Signa a of Owner/Agent Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size r �Cr t 3 Jam( Frontage Setbacks Front Side L:Ea11 R: 1'r Rear Building Height l Bldg.Square Footage S % Open Space Footage 1 % (Lot area minus bldg&paved ! parking) 1 #of Parking Spaces " Fill: (volume&Location) A. Has Has a Special Permit/Variance/Finding ever been issued for/on the site? NO Q DONT KNOW Q YES IF YES, date issued:, IF YES: Was the permit recorded at the Registry of Deeds? NO Q DONT KNOW IS YES IF YES: enter Book Page` and/or Document# P B. Does the site contain a brook, body of water or wetlands? NO J DONT KNOW Q YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained O Obtained Q , Date Issued: C. Do any signs exist on the property? YES Q NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES O NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing, grading,excavation,or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES Q NO 0 IF YES,then a Northampton Storm Water Management Permit from the DPW is required. xi fYV'. h i 2';`��h �� �7w��.���.'Ix�F �1-s�� syr'�5R2'�??•'��I t,, I {{ City of Northampton Status,ofPermrt ` 17} I N'+ �� i phkt 4 5 ; r�, '4 'a� i• d,3 Building Department Curb Cult/DrfyewayPerrrttt % st TO" 8:w*; /S212 Main Street M ' t u MAY 2 3 2014 v i Room 100 Water/V1�eilAva�laf;lllty No hampton, MA 01060 Twa'StsofStrtrctiuCal PIaBS`' Plumbing GO mn&44� 87-1240 Fax 413-587-1272 PIot7Slid Plans "I't' A 01 60 E I ElectrlC, �' n,M n n s nr: r^j NUI r' OtherispeCi� It APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be'completed by office Map Lot Un Zone _:. Overla Distract wA �w ,' v//� /062__ Elm St!District CB Dlstnct SECTION 2 PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: l'1 /l.'mil —P N Name(Print) Current Mailing Address: Telephone 13 v {� ( Iv Sign re �" O O T 2.2 Authorized Agent: ; Name(Print) Current Mailing Address: Signatulee Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by ermit applicant 1. Building C?w (a)Building Permit Feb z:�2 2. Electrical © 0 0 (b)Estimated Total Cost of ( ( Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) � 5. Fire Protection 6. Total=(1 +2+3+4+5) o Check Number �,c This Section For Official Use Only Date Building Permit Number: Issued: Signature: Building Commissioner/Inspector of Buildings Date File#BP-2014-1238r�l APPLICANT/CONTACT PERSON SCHAEDIG CYNTHIA ADDRESS/PHONE 105 CLEMENT ST FLORENCE (413)588-4549 Q V PROPERTY LOCATION 105 CLEMENT ST MAP 30C PARCEL 052 001 ZONE SR(100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Buildinp,Permit Filled out Fee Paid Typeof Construction: CONSTRUCT MUDROOM/BEDROOM/DECK ADDITION, STORAGE ADDITION TO GARAGE,CONVERT BEDRM TO BATH,ROOFING,SIDING New Construction Non Structural interior renovations Addition to Existing Accessory Structure Buildine Plans Included: Owner/Statement or License _ c� 3 sets of Plans/Plot Plan I�`/C—_Ze6A is 7 4 ti/ THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESENTED: pproved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Demolition Delay �'6 24A-J d- f / 04, Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of Planning&Development for more information. 105 CLEMENT ST BP-2014-1238 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 30C-052 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: ADDITION BUILDING PERMIT Permit# BP-2014-1238 Project# JS-2014-001817 Est. Cost: $65000.00 Fee: $390.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: Homeowner as Contractor Lot Size(sq. ft.): 14505.48 Owner: SCHAEDIG CYNTHIA Zoning-: SR000) Applicant. SCHAEDIG CYNTHIA AT. 105 CLEMENT ST Applicant Address: Phone: Insurance: 105 CLEMENT ST (413) 588-4549 O FLORENCEMA01062 ISSUED ON.61512014 0:00:00 TO PERFORM THE FOLLOWING WORK:CONSTRUCT MUDROOM/BEDROOM/DECK ADDITION, STORAGE ADDITION TO GARAGE,CONVERT BEDRM TO BATH,ROORNG,SIDING POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Sisnature: FeeType: Date Paid: Amount: Building 6/5/2014 0:00:00 $390.00 212 Main Street, Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner