Loading...
25C-030 (10) FF'011 LYHH -JECII-ESSER C.PBEi PHONE t,U, - 1 41-3, 569 0662 J,3n, 24 12000 02: 1_7pf" F3 0 DUCT CONSTRUCTION - I 1 All ducts must be sealed with mastic and fibrous backing tape . Pressure-sensitive tape may be used for fibrous ducts . Z`ie HVAC system must provide a means for balancing air and water systeris . TEMPERATURE CONTROLS : Thermostats are required for each Separate HVAC system. A ma_rnaal or automatic means to partially restrict or sb-uL off the heating and/or cooling input to each zone or floor shall be provide('_5 . RVAC EQUIPMENT SIZING: Rated output capacity of the heating/cooling system is not greater than 125k of the design load as specified, in sections 780CMR 1310 and J4 ,4 . MISC REQUIREMENTS: Refer to 780 CMR, Appendix J for requirements relating :o swiamtinq pools, HVAC piping conveying fluids above 120 F or chi"­led fl�ji_Js below 55 F, and circulating hot water systems , -----NOTES TO FIELD (Building Department Use FROH : LYNN DECHESSER CPBD PH01,1E [10. 1 413 569 0612 jat-i. 2000 C2:22,JF-t' F`2' KAScheck :149PECTION CHECKLTST Massachusetts Energy Code KAScheck Software Version 2 ,0 NORTHERN AVENUE DATE: 1-2-2000 Bldg. Dept. Use CEILINGS: 1. R-38 Comments/LoCat ion---.- L 1 2 . R-38 Conrnents/Location_. L 1 3 . R-38 Comments/Location WALLS, : 1. Wood Frame, 16" 0 ,C. , R-11 Comments/Location WINDOWS AND GLASS DOORS : 1. U-value: 0 .25 For windows without labeled U-values, describe featureii: # Panes Frame Type Thermal Break? Yes I X:) Comments/Location- 2 . U-value : 0 .30 For windows without labeled U-values, describe features- # Panes_— Frame Type— Thermal Break? Yes No Comments/Location _ _ SKYLIGHTS : 1. U-value : 0 .24 For skylights without labeled U--values, describe featt-rei!3 : # Panes­ Frame Type— Thermal Break? 'Yes C !',R) Comments/Location----_-____ DOORS : 1 . U-valve : 0 .16 Comments/Location 2 . U­value : 0 .28 Comment s/Location__.________ FLOORS : 1. Over Unconditioned Space, R-19 Comments/ HVAC EQUIPMENT EFFICIENCY: I. Furnace, 90 .0 AFUE or higher. Make and Model Number THERMOSTATS : Adjustable thermostats required for each HVAC system. AIR LEAXAGE ! I Joints, penetrations, and all other such openings in the envelope that are sources of air leakage must he sealed. RuCIC-SSS(i lights must be type IC rated and installed with no pene"--ratlicr.cs or installed inside an appropriate air-tight assembly with, a C . 511 FROM : LYNN DECHESSER CPBD PHONE NO. : 1 413 569 0612 Jan. 24 2000 02:21PM P1 rp n _ .. MAScheck COMPLIANCE REPORT Massachusetts Energy Code Permit # MAScheck Software Version 2 .0 FED 2 8 20M k Checked by/Date CITY: STATE: Massachusetts HDD: 6614 CONSTRUCTION TYPE: 1 or 2 family, detached HEATING SYSTEM TYPE: Other (Non-Electric ResistanCe) DATE: 1-2-2000 DATE OF PLANS; JANUARY 24, 2000 TITLE: NORTHERN AVENUE PROJECT INFORMATION: MCCUTCHFON DEVELOPMENT 12 TURKEY HILL ROAD WESTHAMPTON, MA. COMPANY INFORMATION: LYNN F. DECHESSER, RESIDEN'T'IAL DESIGNER 74 CONGAMOND ROAD SOUTHWICK, MA. 01077 413-,569-0612 NOTES: OPTIONAL SKYLIGHT AT PORCH IS NOT INCLUDED IN CALCULATIONS COMPLIANCE: PASSES Required UA - 335 Your Home - 279 Area or Insul Sheath Glazing/Door Perimeter R-Value R-Value U-Value UA CEILINGS 204 38.0 0 .0 6 CEILINGS 518 38 .0 0 .0 16 CEILINGS 532 38 .0 010 16 WALLS: Wood Frame, 16" O.C. 1392 13.0 0 .0 115 GLAZING: Windows or Doors 175 0 .250 44 GLAZING: Windows or Doors 21 0 .300 6 GLAZING: Skylights 32 0 .240 8 DOORS 21 0 . 160 3 DOORS 21 0 . 280 6 FLOORS: Over Unconditioned Space 1236 19 .0 59 HVAC EFFICIENCY: Furnace, 90.0 AFUE COMPLIANCE STATEMENT; The proposed building design represented in these documents is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the requirements of the Massachusetts Energy Code. The heating load for this building., and the cooling load if appropriate s�v a V1�k�lLaqu. dS-t r4A @" �- - s*MA§und