Loading...
25C-027 (2) 03/24/2005 15:09 4132478338 RUGG LUMBER VAUL U1 Wright Builders-Hathaway-Balm 03/24/05 KeylRealii>iR I:5Ipm !^� 1 of 1 rcayrbacn4e V■rYipR 4.I0 Pmobw v 5 Wn*er Data Description: Member Type:Beam Application:Floor Lateral Bming:Continuous Standard Load: Moisture Condition:Dry Building Code.UBC Live Load; 40 plf Deflection Criteria: L/360 live,L/240 total Dead Load: 10 plf Deck Connection:Nailed Member Weight: 16.7 plf DOL: 100% Filename:KY01 Nan-standard Loads Type Trib. uve Dead (Daseriptio n) Begin End Width Stem End start End DOL Replacement Uniform(pef) 0' 0.00" 13' 3.00" 6' 0.00" 20 10 100% Replacement Uniform sf 0' 0.00" 13' 3.00" 6' 0.00" 40 15 115% 1330 13 30 Bearings and Reactions input Ilan mjm worst can Loostbn Type Lwwth Lwolh Tom! 11 VK 100% Dead ..■ TOM 1 0' .00" Wan WA 1.50" 3628# 1608# 004# 1117# 35280 2 13'4.75" Wall WA 1.50" 3528# 16080 8049 1117N 3628# Design spans IV 4,75" Product;2.0 Rlgk Lam LVL 1.30 x 11.175 3 ply Offin en 1.50"bearing TwwkRpd at bearing*/ Wr*man 1.50"bewbV requkad at bearing 9 2 Oesign assumes corNirawus fatsrai bracing for both chords. A lowaN>tie Stress Design ACkol Allowable Capaeftyr Leealbn LDa av Positive Moment 11814.'# 35710.'1 33% a.T TOW 10ad 115% Shear 3007.0 73622.#1 22% 12.73' Totes bad 11596 LL Deflection .17130" .4485" L/803 6.7' Taal load 116% TL Deflection 2w .6698" U817 6.r Total bad 115% Control: LL i>an Ion Dmgn assuftm o rePe hw mRrnber use Mdssee In bwd g si msc 4 X MemAaawmee instAlegon gukie MUST be eonsuNd tow nn^-ply cvnnedbn dskWk and auema4vos AS oaoA■a a■undo m d mw. ewat C W4M(C)tSRw•=bV VAY■"LWO]w■.4x.AU.RCMYe RESERVED. e""JrK l?3/L4/L1700 10:19y 413L4/C330 rcL"a L.umauc .,+„yj,I_-natLnaWay.L09 , a4 Page 2 of 2 Control : Shear NOTE: Consult Manufacturer's installation Guide for multi-ply connection details and alternatives All product names are trademarks of their respective owners Copyright (C) 1989-2000 by Keymark Enterprises, Inc. All Rights Reserved. 03/24/2405 15:09 41314/H:3:ii3 KUI:A2 LUMOLK rout 00 ....-7...,-,.aLuexway.Lu/ , S4 Page 1 of 2 KeyBuild structure _(. / 03/24/05 Version 2.128d I t�7 e-cL G,,_. :�G a 7 lk v ��.�C� 12 :24 PM Filename : Wright-Hathaway.L07 Member Type: Beam Description: B4 Application: Floor Comments: Lateral Bracing: Continuous Building Code: UPC Deck Connection.: Nailed Location: Live Load: 0 plf Slope. Dead Load: 0 plf Moisture Condition: Dry DOL: 100$ Member Weight: 13 .0 plf Deflection Criteria: L/360 live, L/240 total Non-standard Loads (Uniform loads replace Standard Loads) : Live Dead Type Begin find Start End Start End DOL Unif. (plf) 01 .00" 1 ' 6.00" 160. 0. 115% Unif . (plf) Oe . 00" 1' 6.00" 160. 0. 115-W Unif. (plf) 0' .00" 11 6 .00" 290. 268. loot Unif. (plf) 0' .00" 1 ' 6. 00" 320. 279. 100% Unif. (plf) 1' 6.0011 13' .00" 27. 10. 100 Unif. (plf) 11 6.00" 131 .00" 320. 0. 115$ Unif . (plf) 1' 6.00" 13, .00" 320. 438 . 100$ Point(lbs) 1' 6.00" 2580. 1091. 1009.1 XXXXXXvXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX - n ' 13 ' .00" Exact Member Length: 13 , .00" Reactions with all loads applied (lbs) : 11091. 7786 . Worst case (alternate load analysis) reactions at each support (lbs) : Used for connector/min. bearing design and as a point load on carrying member. 115k 2080. 2080. 1005 4908. 2574. Dead 4103 . 3132. Total 11091 . 7786. Bearing Length: 4 .22" 2. 9711 *,ttrw*,trrww*l rw,rw�+rwws*w**rtw,r**w+w*+wer+raw+kir+tw*w*ww*,tl rwx*tr,►w+t>}w,t**w,r***,r*,e*w+r,t,� Product: 2 .0 RigidLam LVL 1-3/4 x 14 3 ply era,r*w**xx,.x**e►w*w*w+r�wt**,►x**ww,r,r,e,�w*ww***,r,r**•*�r+ww#**waw,ew*,w*w*��w***+r** Allowable Stress Design Actual Allowable Capacity Location Loading Moment 26878. 0# 31169. 1# 86% Span one Total load 1151 Shear 93534 10707.# 87% Span one Total load 115% 'L Deflection .31" _43" L/495 Span one Total load 115% CL Deflection . 52" .65" L/300 Span one Total load 115% liJl Lot Lt7t77 10:17y 41JL4It73JD MLAYUL-nacnaway.L07 Page 4 of a Shear 1245.# 6318.# 19t span one Total load 100* LL Deflection .11" .37" L/999+ Span one Total load 100W TL Deflection .1511 .55" L/873 Span one Total load 100% Control: Live Load Defl. NOTE: Consult Manufacturer's installation Guide for multi-ply 8 connection, details and alternatives All product names are trademarks of their respective owners Copyright (C) 1989-2000 by Keymark Enterprises, Inc. All Rights Reserved. Ud/'L4/"L13135 10:1311 413'L4/tlJJU -- �al� Ou13tL lor: wr.%gAt-H&thaway.LO7 Page 3 of 4 KeyBuild Structure 03/24/05 Version 2.128d I34��n ���nt✓ kra�tat �iClh 7 12 :24 PM (� � �►, Filename Wright-Hathaway.L07 Member Type: Beam Description: B2 Application: Floor • Comments: Lateral Bracing: Continuous Building Code: UBC Deck Connection: Nailed Location: Live Load: 0 plf Slope: Dead Load: 0 plf Moisture Condition: Dry DOL: 100% Member Weight: 9.0 plf Deflection Criteria: L/360 live, L/240 total Non-standard Loads (Uniform loads replace Standard Loads) : Live Dead Type Begin End Start End Start End DOL Unif. (plf) 01 .00t1 11 .00" 60. 23 . 100 Unif. (plf) 1' .00" 2' 0011 80. 30. 100$ Unif. (plf) 2 ' .0011 3 ' .00" 100. 38. 100% Unif. (plf) 3 ' .001, 41 .001' 120. 45 . 100% Unif. (plf) 41 .00" 51 .00" 140. 53. loot Unif. (plf) 5' .0011 6' .001, 160. 6o. 100% Unif. (plf) 61 .00" 71 ,00" 180. 68 . 100% Unif . (plf) 71 . 00" 8' .00" 200. 75, 100% Unif . (plf) 81 oo" 91 .0011 220. 83 . 100% Unif . (plf) 9' .00" 10' .0011 240. 90. 100% Unif. (plf) 10' .00f1 111 .00" 260. 98. 100$ XXXXXXXXXXXXxxxxxxXXxxxxxXXXXXXXXXXXXXXXXxxxxxxxxxx xxx xxxxx =sacsma�:ssa�mas==�smaQ+e.rases$c.se ls>:as==�s�esmc===sxcsmc=aesas - A 11' .0011 Exact Member Length: 111 . 0011 Reactions with all loads applied (lbs) : 985. 1535. Worst case (alternate load analysis) reactions at each support (lbs) : Used for connector/min. bearing design and as a point load on carrying member. loot 680. 1080. Dead 305. 455. Total 985. 1535. Bearing Length: 1.50" 1.50" t+r** ►wr,rws+r*vrwytr+t*�r*�w,r+r�� Mrt.v**,►*wwrek***,rw+r**rt*,tr*>trt*trwt,r,tt,t�rw,1*,►*tr,4+rvr*#,r*�+r Product: 2.0 RigidLam LVL 1-3/4 x 9, 5 2 ply wr+tkw,F,►wrt***wAww*,r,F,lr*itt*,vtxw�itih*rlr*k,t*ww,tir,M*w+r**,t�r�+t*rt*,Y*wtx*,4ww*Yrlt,txwrt+F+t,4+t Allowable Stress Design Actual Allowable Capacity Location Loading Moment 3509. 1# 13100 . 14 26%- Span one Total load 100* Ud1 Z4l:ZV170 13:011 413L410ijo MAWR Lu.V��� - _ •-•-- - .VL. nj_1g11L-naLnaway.L07 Page 2 of 4 Control : Moment NOTE: Consult Manufacturer's Installation Guide for multi-ply connection details and alternatives ({{` All product names are trademarks of their respective owners Copyright (C) 1989-2000 by Keymark Enterprises, Inc. All Rights Reserved. 03124/2005 15:09 4132476338 ftUbU LUMtStK rant no Page 1 of 4 ReyBuild Strtactur }} // 03/24/05 Version 2 .128d �&VK W t 9vtil Gc.elC.GY /"a V+'�•f`� 12!24 PM Filename : Wright-Hathaway.1,07 Member Type: Beam Description: B1 Application: Floor Comments: Lateral Bracing: Continuous Building Code: UBC Deck Connection: Nailed Location: LiVe Load: 0 pIf Slope: Dead Load: 0 plf Moisture Condition: Dry DOL: loot Member Weight: 9.0 plf Deflection: Criteria: L/360 live, L/240 total Non-standard Loads (Uniform loads replace Standard Loads) : Live Dead Type Begin End Start End Start End DOL Unif. (plf) 0' .00" 1' .00" 222. 83 . 100% Unif. (plf) 1' .00" 2' .00" 202 . 76. 100¢ Unif . (plf) 2' .00" 3 ' .00" 182. 68 . 100% Unif. (plf) 3 ' . 00" 4' .00" 162. 61. 100% Unif. (plf) 4 ' . 00" 5' 00" 142. 53. 100% Unif. (plf) 5' .0011 6' .00" 122. 46. loot- Unif . (plf) 61 .00" 7' .0001 102. 38. 1001 Unif. (plf) 7' .Ofl" 8' .00" 82. 31 . 1001 Unif. (plf) 8' .001' 8' 6.00" 67. 25 . 100% xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx ��.:aea�scx=m==a�rs�=assns=s�acx-�xc=ems.-:asameaav:s=Asa-_��m�=mom_ - n 8 '6 .00" Exact Member Length: 8 ' 6.00" Reactions with all loads applied (lbs) : 1063. 736. worst case (alternate load analysis) reactions at each support (lbs) : Used for connector/min. bearing design and as a point load on carrying member. 100% 745. 508. Dead 318 . 229. Total 1063. 736. Bearing Length: 1 ,50" 1150" k*#,krf*wi+e***,r***,k**ts,xYtirdrkkfkirt+F*.►rkrt*t*,ktt3+k'k*rt,tX***1i'**,kur*,tir*titr*,tit+*tr,t+k***x,r Product: 2.0 RigidLam LVL 1-3/4 x 9.5 2 ply �*�****,.+►***irk*#,.�**.****w****,r,r*1M***ww***�,►� 1r,►w*,r,.,.**,.+r***X,r�#,.**{e*k*,r,►*k* Allowable Stress Design Actual Allowable Capacity Location Loading yoment 1923 . 1# 13100. 1# 10 Span one Total lead 100% Shear 812.# 6318.# 12% Span one Total load 100% :L Deflection .03" .28" L/999+ Spam one Total load loot CL Deflection .05" .43" L/999+ Span one Total load 100% VM(z-00H RECEIVED JUN 2 2 1998 ENERGY CONSERVATION APPLICATION FORM FOR LOW-RISE RESIDENTIAL NEW CONSTRUCTION and ADDITIONS 780 CMR Appendix J (effective 3/1/98) Applicant Name: 1NMNT 'Rtl11.D s Site Address: 32 ► *T1,og ► Applicant Address: 416 City/Town: wfg-" f no Mk 0PE2!b"1VN,MA- Use Group: 5i1 m t-_ -FAM of Date of Application: 5 Is 10(; Applicant Phone: 9)6-9p-41, Applicant Signature: Compliance Path(check one): [� Prescriptive Package (Limited to 1- or 2-family wood frame buildings heated with fossil fuels only) Package(A through KK from Table J5.2.1 b): Heating Decree Days (HDD55) from Table J5.2.1 a: (For items d.through i., fill in all values that apply from Table J5.2.I b:) a. Gross Wall Area sq.ft f. Wall R-value R- b. Glazing Area` sq.ft. g. Floor R-value R- C. Glazing%(100 x b_a) % h. Basement wall R- d. Glazing U-value U- i. Slab Perimeter R- e. Ceilins R-value R- j. Heating AFUE F] Component Performance: "Manual Trade-Off'(Limited to wood or metal framed buildings only) Climate Zone(from Figure 16.2.2) C] Zone 12 F� Zone 13 F� Zone 14 Attach Trade-Off Worksheet from Appendix J, (and HVAC Trade-Off Worksheet, if applicable; M AMScheck Software Attach Compliance Report and Inspection Checklist printouts. M Systems Analysis OR [] Renewable Energy Sources Attach Mass-Registered Architect or Engineer_AnaLysis_._._____ ___ ALTERNATIVE FOR ADDITIONS ONLY: a. Gross Wall + Ceiling Area x512- sq.ft. b. Glazing Area' '; sq.ft, c. Glazing °'° (ico x b-a) °'° ADDITION with Glazing% (c.) up to 40% may use 780 CMR Table J1.1.2.3.1 below: NLAXENIUNI U-value MININUUM R-Values Fenestration Ceiling Wall Floor I Basement Wall I Slab Perimeter.Depth 0.39 R-37 R-13 R-19 1 R-10 R-10,O ft F1 "SLT ROOM"addition (greater than 40% glazinb to-wall and ceiling gross area) Attach"Consumer Information Form" from 780 CiVIR Appendix B. Official's Name: Official's Signature: Application Approved Q Denied ❑ Date of ApprovaUDenial: Reason(s) for Denial: (provide additional details as needed on back side) ' Glazing Area may be either Roue Opening or unit dimensions. BBRS 06;12.93 IW1t j �LDWI RECEIVED JUN 2 2 1998 ENERGY CONSERVATION APPLICATION FORM FOR LOW-RISE RESIDENTIAL NEW CONSTRUCTION and ADDITIONS 780 CMR Appendix J (effective 3/1/98) Applicant Name: W(z-IM WtMLIL*MS Site Address: 32 9b?-rft-F A A\f'G- Applicant Address: 41h 19Prt City/Town: MN t40 MNI° Use Group: SjK6r1)E� i-wM Date of Application: V5 3 1 vS Applicant Phone: Applicant Sipature: Compliance Path (check one): 7 Prescriptive Package (Limited to 1- or 2-family wood frame buildings heated with fossil fuels only) Package(A through KK from Table J5.2.Ib): Heating Degree Days (HDD65) from Table J5.2.1a: (For items d.through i., fill in all values that apply from Table J5.2.1 b:) a. Gross Wall Area sq.ft f. Wall R-value R- b. Glazing Area' sq.ft. g. Floor R-value R- c. Glazing%(100 x b_a) % h. Basement wall R- d. Glazing U-value U_ i. Slab Perimeter R- e. Ceiling R-value R- j. Heating AFUE Component Performance: "Manual Trade-Off' (Limited to wood or metal framed buildings only) Climate Zone(from Figure J6.2.2) Zone 12 Zone 13 Zone 14 Attach Trade-Off Worksheet from Appendix J, (and HVAC Trade-Off Worksheet, if applicable; F-1 AMScheck Software Attach Compliance Report and Inspection Checklist printouts. Systems Analysis OR F� Renewable Energy Sources Attach Mass-Registered Architect or Engineer-AnaLysis_.--__-- --- -- — ----- ALTERNATIVE FOR ADDITIONS ONLY: a. Gross Wall + Ceiling Area�sq.ft. b. Glazing Area' b7D sq.ft. c. Glazing °'o (1eo x b-al ADDITION with Glazing% (c.) up to 40% may use 730 Cti1R Table J1.1.2.3.1 below: ,NL4YI�1LN1 i-value MIN EMU M R-Values Fenestration Ceiling wall Floor I Basement Wall Slab Perimeter,Depth 0,39 R_37 R-13 R-19 R-10 R-10.4 ft "SLrZtOOLNI"addition (greater than 40% glazing-to-wall and ceiling gross area) Attach"Consumer Information Form" from 780 C*NIR Appendix B. Official's Name: Official's Signature: Application Approved 0 Denied 7 Date of Approval/Denial: Reason(s) for Denial: (provide additional details as needed on back side) ' Glazing Area may be either Rough Opening or unit dimensions. BBM 06;1198 IDWOL X060 WjtA? OMT w Zrd s`t � RECEIVED J0 2 2 1998 ENERGY CONSERVATION APPLICATION FORM FOR LOW-RISE RESIDENTIAL NEW CONSTRUCTION and ADDITIONS 780 CMR Appendix J (effective 3/1/98) Applicant Name: WWI 'Gi "Ielf-S Site Address: Applicant Address: 4 91 ?-A SS" C ity/Town: MT-1A WeTD M N46ILntPkl_ DN , MFX- Use Group: ISIKI;'w F (ft\jq Date of Application: 6) 13 I DS Applicant Phone: 4f, r7'6 lv'16_3 K1 Applicant Signature: Compliance Path (check one): F1 Prescriptive Package (Limited to I- or 2-family wood frame buildings heated with fossil fuels only) Package (A through KK from Table J5.2.Ib): Heating Degree Days (HDD65) from Table J5.2.1a: (For items d.through i., fill in all values that apply from Table J5.2.1b:) a. Gross Wall Area sq.ft f. Wall R-value R- b. Glazing Area' sq.ft. g. Floor R-value R- c. Glazing%(100 x b_a) % h. Basement wall R- d. Glazing U-value U- i. Slab Perimeter R- e. Ceiling R-value R- j. Heating AFUE F1 Component Performance: "Manual Trade-Off' (Limited to wood or metal framed buildings only) Climate Zone(from Figure J6.2.2) F� Zone 12 F7 Zone 13 Zone 14 Attach Trade-Off Worksheet from Appendix J, [and HVAC Trade-Off Worksheet, if applicable] AMScheck Software Attach Compliance Report and Inspection Checklist printouts. Systems Analysis OR 7 Renewable Energy Sources Attach Nlass.Registered Architect or Engineer-AnaLysis- - ALTER-NATIVE FOR ADDITIONS ONFLY: a. Gross Wall + Ceiling Area 4r1r2 S.A. b. Glazing Area' bb sq.ft. c. Glazin` °'a (1C0 s b_a) .,2� % ADDITION with Glazing% (c.) up to 40% may use 730 CNIR Table J1.1.2.3.1 below: NLXXIMtM L;-value MINIMtiM R-Values Fenestr2tion Ceiling Wall Floor I Basement Wall Slab Perimeter.Depth 0,39 R-37 R-13 R-19 I R-10 R-10,O ft "SLTTROOM"addition (greater than 40% glazing-to-wall and ceiling gross area) Attach"Consumer Information Form" from 730 CN1R Appendix B. Official's Name: Official's Simmature: Application Approved ( Denied 7 Date of ApprovaUDenial: - 1Clo r Reason(s) for Denial: (provide additional details as needed on back side) ' Glazing Area may be either Rough Opening or unit dimensions. BBRS 00,12-93 S � "DITION A_" NT- OF ftnSt_ RECEIVED MI 2 1998 ENERGY CONSERVATION APPLICATION FORM FOR LOW-RISE RESIDENTIAL NEW CONSTRUCTION and ADDITIONS 780 CMR Appendix J (effective 3/1/98) Applicant Name: y*101 y -R1AILID 6-S Site Address: 'L 1�� N We, Applicant Address: AJ�5 VIM15 ST_ City/Town: �1t5(� {'�N �` A 1•�1T� �kMQ`(D_ t4 to Use Group: 51t4,6-AX f 1wIV� _ Date of Application: V51,6 0S Applicant Phone: TbU`626-7 Applicant Signature: Compliance Path(check one): F� Prescriptive Package (Limited to I- or 2-family wood frame buildings heated with fossil fuels only) Package(A through KK from Table J5.2.Ib): Heating Dezree Days (HDD,S) from Table J5.2.Ia: (For items d.through i., fill in all values that apply from Table J5.2.1 b:) a. Gross Wall Area sq.ft f. Wall R-value R- b. Glazing Area' sq.ft. g. Floor R-value R- c. Glazing%(100.x b_a) % h. Basement wall R- d. Glazing U-value U- i. Slab Perimeter R- e. Ceiling R-value R- j. Heating AFUE Component Performance: "Manual Trade-Off' (Limited to wood or metal framed buildings only) Climate Zone (from Figure J6.2.2) C3 Zone 12 F� Zone 13 C] Zone 14 Attach Trade-Off Worksheet from Appendix J, [and HVAC Trade-Off Worksheet, if applicable] MAScheck Software Attach Compliance Report and Inspection Checklist printouts. F-1 Systems Analysis OR [D Renewable Energy Sources Attach Nlass_Registered Architect or Engiaeer.AnaLysis_._._____ - ALTERNATIVE FOR ADDITIONS ONLY: 3 _sq.ft. b. Glazing Area'��sq.ft. c. Glazing °'o (ic0 x b-al a. Gross Wall +Ceiling Area ADDITION with Glazing% (c.) up to 40% may use 780 CMR Table J1.1.2.3.1 below: tit�YhN1L'M ti-value MINIMUNt R-Values Fenestration Ceiling Wall Floor Basement Wall Slab Perimeter.Depth 0,39 R-3 i R-13 R-19 R-10 R-10,a ft "SLNi ROOLNI"addition (greater than 40% glazing-to-wall and ceiling gross area) Attach"Consumer Information Form" from 730 CMR Appendix B. ,n Official's Name: .71`1L-.. Official's Signature: Application Approved C Denied C] Date of ApprovaLDenial: J Reason(s) for Denial: (provide additional details as net-ded on back side) ' Glazing Area may be zither Rough Opening or unit dimensions. Betts oo;t.as 3 L -q of �Wcrt4alllptjar OF 3UILLING INSPECTIONS ti`c 5 e 212 Main Street ' Municipal Building IN„R_CTOR -- horthampton, INiass. 0I060 Scuare-Fcotace A-rcunt Bazement @ 1st __ccr 2nd _ '_ccr @ 1/2 =lccrs, Attic, Garace 15 Pcrc`tes "is �/'/ �• 3a File No.I)W90,5 ZONI G PERMIT APPLICATION § 10.2 Complete this form using your computer and the free Adobe PDF Reader (http://www.adobe.com/products/acrobat/readstep2.htm1). Print the completed form, sign it, and return it to the Building Inspector's Office together with the $15 filing fee (check or money order) payable to the City of Northampton. 1. Name of Applicant: IX P U1 phi�D S Address: 4�-) 5 City: State: i./j(lc Zip: C,(O(,-,O Telephone: 2. Ownerof Property: GT7E-/F WmtftNft4 s �(� �t1Z��N �ViTZ Address: f4ccw�t-S City: ��(`' I�t kM �N State: Zip: C) i LD 1,, 0 Telephone: -, 3. Status of Applicant: Owner Q Contract Purchaser Q Lessee 0 Other (explain) �- 4. Job Location: L Town: too f rZf� Parcel Id: Zoning Map# Parcel# District(s): _6/ .4— In Elm Street District In Central Business District (TO BE FILLED IN BY THE BUILDING, 5. Existing Use of Structure/Property: 5 i��(lsl,� ��'M l ty �-�v1•/� 6. Description of Proposed Use/Work/Project/Occupation: (Use additional shee if necessary): � S tt NEW rJD� AT � Avg NEW �y f1`c °N i dN ISn N� o N E S-r��-�I 1� ex7� - C?�I D'P* g�v i NON b x J`f%' � 7v�'� �1/>nF �v A,ht r ,5 j'C tb EY�N> 7c rsT'G b,'N 'j 4 6�p�obM � r d^'L Sfv� �� �oN AT e,`rnf r-bF-nr - p4M,'�I, G,/k 7. Attached-Plans: Sketch Plan Q Site Plan Engineered/Surveyed Plans Altily X la-` �} SThn_-tj 8. Has a Special Permit/Variance/Finding ever been issued for/on the site? ON bV�1- 5"Pe NO Q DON''T KNOW YES Q IF YES, date issued: / / M L/a(—o o qf' 4A-Dr - IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DON''T KNOW Q YES C IF YES: Book Page and/ Document# or 9. Does the site contain a brook, body of water or wetlands? NO .jg�' DON''T KNOW Q YES 0 IF YES, does a permit need to be obtained or has a permit been obtained from the Conservation Commission? A permit needs to be obtained Q A permit has been obtained 0 and was issued: 000.pdf File#MP-2005-0105 APPLICANT/CONTACT PERSON Wright Builders ADDRESS/PHONE 48 Bates St (413) 586-8287 PROPERTY LOCATION 32 NORTHERN AVE MAP 25C PARCEL 027 001 ZONE URB THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM F LED OUT Fee ai Building Permit Filled out Fee Paid T_ypeof Construction:_ZPA-DECKS, 1 &2 STORY ADDITIONS&RENO New Construction Non Structural interior renovations Addition to Existing_ Accessory Structure Building Plans Included: Owner/Statement or License 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFO ATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER: § Intermediate Project: Site Plan AND/OR Special Permit with Site Plan Major Project: Site Plan AND/OR Special Permit with Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street mmission r � ZZJ c h 1-5 Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact the Office of Planning&Development for more information. SECTION 8 -CONSTRUCTION SERVICES 1 Licensed Construction Supervisor: � � Not Applicable ❑ Name of License Holder: N"T 1 `"' 1"' `' CS o(D C6 License Number ALA-I 0 (0 Address Expiration D to 4A-2 Signature Telephone - �ere v r Not Applicable ❑ \AJP(:-_V_ _BU W);Ef—S I ti t U79-3 to Company Name Registration Number 0 3�� � S— rare J L- I 2_tp I o(49 Address p Expirati n Dat Telephone`��tt j-; �16� T72� l�-7 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,'§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... No...... ❑ The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780. Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature 7CTION 5- DESCRIPTION OF PROPOSED WORK(check ell applicable) New House ❑ Addition )91 Replacement Windows Alteration(s))q Roofing Or Doors ❑ Accessory Bldg. ❑ Demolition❑ New Signs [ ] Decks] Siding Other[ ] Brief Description of Proposed Work:-TWO-S up gtum"0111ONi k SIT / A N 5T* W, 2Pd r,TMy Am-no r4 Fpor rr s Atr� Alteration of existing bedroom _Yes No Adding new bedroom Yes X No Attached Narrative❑ Renovating unfinished basement Yes X No Plans Attached Roll❑- Sheet❑ 6's lf'1Ve ouse and or addition o exis In ho�i's1-fi mOC piefe"fhe fotlowEn> : a. Use of building: One Family )'� — Two Family Other b. Number of rooms in each family unit: Number of Bathrooms_ c. Is there a garage attached? Na 0 d. Proposed Square footage of new construction. ZZ Dimensions e. Number of stories? f. Method of heating? C,jAS � � STIE�A M Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. y�S Mascheck Energy Compliance form attached? e S Type of construction i. Is construction within 100 ft. of wetlands? Yes _,A_No. Is construction within 100 yr. floodp lain Yes X No j. Depth of basement or cellar floor below finished grade i11e% C� A/ q fact - 4 f k. Will building conform to the Building and Zoning regulations? f, Yes No . I. Septic Tank City Sewer X Private well City water Supply — _SECTION 7a.:,OWNER AUTHORIZATION-TO BE COMPLETED WHEN f OWNERS AGENT OR'CONTRACTOR APPLIES FOR BUILDING PERMIT ,,^ as Owner of the subject property UJ ` ;iera,:'. authorize T Ll S T l I✓1"t�. to act on my behalf, in all matters relative to work authorized by this building permit application. _ "Signature of Owner Date as Owner Authonzed A ent herebbydeclare that the statements and information on the foregoing application are true and accurate,t the est of my knowledge and belief. Signed under the pains and penalties rjury. Print Name Date Signatu a 0 ner/Agent _ Section 4. ALL INFORMATION MUST BE COMPLETED, or PERMIT CAN BE DENIED DUE TO LACK OF INFORMATION 2� ©S S S f�trt��t 4�D '?x N t r�6- Qv—M 1 T- ppV15j 3 1 Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage % Open Space Footage % (Lot area minus bldg&paved parking) #of Parking Spaces Fill: (volume&Location) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO DON'T KNOW 61 YES IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO DON'T KNOW YES IF YES: enter Book Page and/or Document # B. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained , Date Issued: C. Do any signs exist on the property? YES NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property?YES_ No IF YES, describe size, type and location: City of Northampton t Building Department t 212 Main Street =Seee ;t Room 100 . Northampton, MA 01060 e phone 413-587.1240 Fax 413.587-1272 0 APPLICATION TO CONSTRUCT, ALTER, REPAIR, RENOVATE OR DEMOLFSH A ONE R ' 6-.`FAMILY DWELLING 4 ppU SECTION 1-SITE INFORMATION 1.1 Property Address: y This section to be com leted } (office ' Map Un►t M A- Zone Overlay Distncf Elm St D�str�ct CB District pry _,..w�. SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: mt ave yu n K *Qme(Print) Cu`r�ent M iling Address: `1%3 IMF y3 c/l '5T�JIE�7iJ � �V� � �1AK� ttSC�►Y-CirVl"CZ Telephone Signature 2.2 Authorized Agent: \NRj(qtj- t p iQ r ?1CAtETTV, B S Sr t� -t I � raN , M#,- Name(Pri Current Mailing Address: 413--q�� -f3^� tgn a Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS � �5� Srz Pkn�" cP�LC. %�T Ii — f71� . Item Estimated Cost(Dollars)to be Official Use Only completed by ermit aoolicant 1. Building (a) Building Permit Fee 2. Electrical `Z 3 tv2 (b)Estimated Total Cost of Construction from 6 `= ` 3. Plumbing Bwlding Permit Fee w yyy h � S K 4. Mechanical (HVAC) 4 ,� y � $ 5. Fire Protection 6. Total =(1 + 2 + 3 +4+ 5) ��0 q Check Number di0 For Official USe'Onl t •xtiin �' ?.� � ate 3 ` ':: ''• ,":,f+K _ s •; �' '+�` r ;,tn r �ww..Fr•n + n Y4 y �4.q'7r, 7 �1S Buikdmg Pert�it Number Da#e Issue X '* ^� +�i'«e• c �+ r-r*M .YIt�:�' w •.e ?' "_:e�'"' r y ly�.,''� +� y-r r ;� • T �9��y�,r c r u� �. -4� t ��y r{,c+. 'e asx t*_z�x�,a�. �r � y* z +.�a*�.� rrya. - -.d j'+pc.�rhv,'r`�+,�Lrw,,;•f 3 V; 4�.'k�w� .a'.t:"a„y.��'1F tiY.Cti`rte{� �"�.. 3�-'i`�'"« �4,�.;P���'M'Y a:..t 'A r«�t..�t•j�l/ ��1�.,. '�Y`�^� t��t',�s°rt�A`�:.d z..v Cr:"�.M,s`�', ,-`.^�i.`.:. ',n r y4�'N's Y-. e t ..<,ky, �..., e? ;c•— y��i''4'ry'.� Mw�`Mry�, u•FE' ,. aw ! "•k"';:��Y '� W-.,'�.'�y � '•i'^S-��C`,^�L: SignaU(e� 'I°.p} s 'Re'YiL.:•.. ��.a+::.0 ".s_'x,..: x +�-,.,�Y !!ik«�`Ln l r ;i. d�, nt.:,' !�e rte% d. •a+x.'.;."+'^ortY a Ze �:'�i.4:� - `u.+�. ,: Building Commissioner/Inspector of,Buildings ;� .`�� + �:H'"^,+, ,k,-,Date "� "�' a "` '��, ` <t.:A "S'V-" File#BP-2005-1082 APPLICANT/CONTACT PERSON Wright Builders ADDRESS/PHONE 48 Bates St NORTHAMPTON (413)586-8287 PROPERTY LOCATION 32 NORTHERN AVE MAP 25C PARCEL 027 001 ZONE URB THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Buildinjz Permit Filled out Fee Paid Typeof Construction: CONSTRUCT 2 STORY MUDROOM ADDITION 1 STORY(FAM RM),2 STORY BUMPOUT&2 STORY ADDITION FRONT&NEW DECK New Construction Non Structural interior renovations Addition to Existin¢ Accessory Structure Building Plans Included• Owner/Statement or License 068185 ���/���� 3 sets of Plans/Plot Plan THE F911OWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFPAMATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Co sion Signature of Building Official Date Note:Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of Planning&Development for more information. 32 NORTHERN AVE BP-2005-1082 GIS#: COMMONWEALTH OF MASSACHUSETTS MW.Block:25C-027 CITY OF NORTHAMPTON Lot: -001 Permit: Building Category: ADDITION BUILDING PERMIT Permit# BP-2005-1082 Project# JS-2005-1225 Est. Cost: $170793.00 Fee: $864.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: Wright Builders 068185 Lot Size(sa. ft.): 17511.12 Owner: HATHAWAY STEPHEN B&MARIE Zoning.URB Applicant: Wright Builders AT: 32 NORTHERN AVE Applicant Address: Phone: Insurance: 48 Bates St (413) 586-8287 Workers Compensation NORTHAMPTON MAO 1060 ISSUED ON.5116105 0:00:00 TO PERFORM THE FOLLOWING WORK-:CONSTRUCU2 STORY MUDROOM ADDITION, 1 STORY(FAM RM), 2 STORY BUM POUT k/2-' STORY ADDITION FRONT- NEW DECK POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspe for Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Sienature: FeeType• Date Paid: Amount: Building 5/16/05 0:00:00 $864.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Building Commissioner-Anthony Patillo 10. Do any signs.exist on the property? Nn1 DON"T KNOW O YES O IF YES, describe: Size: x x length width depth Type: Location: Are there any proposed changes to or additions of signs intended for the property? NO Q DON"T KNOW Q YES 0 IF YES, describe: Size: x x length width depth Type: Location: 11. ALL INFORMATION MUST BE COMPLETED, or PERMIT CAN BE DENIED DUE TO LACK OF INFORMATION This column r eserved foruse b Y the Building De artment EXISTING PROPOSED ,REQUIRED BY ZONING Lot Size (ft') R.DO V 0 Frontage Front l Setbacks Raf Sipe L: 2P�'-3'' R: Zi' L:21'-3•� R: IS, L: R: Rde P4%F, 3l i Z4 Building Height (ft) Building Area (ft ) Ito 2-063 Building Volume (ft') Total Area of Paved DF-WIE Z 5�6 '?�tVt= G'7ie Parking, Decks, and D>� Other Impermeable �£ _ X71 Surfaces (ft2) --ibTr� 9 00 Area (ft ) % Area (ft ) % lot pp lot 115.COO 1.lot Open Space: - building l4lb buildin 2.�q3 - ibuildin - impermeable b_ - impermeable E,;, - impermeable Total MA q. Total rL i -t,% Total # of Parking Spaces # of Loading Docks -- Fill: volume (fe) volume(ft 3) volume(ft') location location location 12. Certification: I hereby certify that the information contained herein is true and accurate to the best of my knowledge. / Date: I /,n / ti S� Applicant's Signature Ll� NOTE: Issuance of a zoning permit does not relieve an applicant's b rden to comply with all zoning requirements and obtain all required permits from the Board of Health, Conservation Commission, Historic and Architectural Boards, Department of Public Works and other applicable permit granting authorities. 000.pdf File No.17)190,510 6 Fri"��,,.H. s.,.y ...,..._,,�. ---Complete tl s form using your computer and the free Adobe PDF Reader (http://www.adobe.com/Oroducts/acrobat/readstepZ.htm0. Print the completed form, sign it, and return it to the Building Inspector's Office together with the $15 filing fee (check or money order) payable to the City of Northampton. 1. Name of Applicant: (51AI' -A'�Uj lA'�S Address: 4,b si- City: j p�,j "t�l,/1P'�rl State: MIN,- Zip: 0(aZo b Telephone: 44-3 2. Owner of Property: GTVF vv 4 ��� IZSG�-l�D6'UiTZ Address: 'AZ per City: W State: �Ak Zip: p (C)(p v Telephone: 4-1;_ f5 rb 3. Status of Applicant: Owner 0 Contract Purchaser 0 Lessee 0 Other (explain) l�r✓ .p�� 4. Job Location: j2, Town: c 5. Existing Use of Structure/Property: 6. Description of Proposed Use/Work/Project/Occupation: (Use additional sheets sh ee if necessary): �EAC- b� • 641 tD N&W A� A-r �AR-. A►vI> NEVU A� icK r-wtr ON 0Ni✓ -tj eA tf D eX(5;P1 (t,-t�4.0o/k r W Nl ► to X 1�%' � ��� ��Mi' 3W A-r- A'6-)f T 5;?�C to &K-tj-Wb ec l'sr'G- b!'N;14- x � 6 oN 7. AttacheMans: Sketch Plan 0 Site Plan Engineered/Surveyed Plans 8. Has a Special Permit/Variance/Finding ever been issued for/on the site? ON NO 0 DON'TT KNOW YES 0 IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DON'T KNOW 0 YES IF YES: Book Page and/ Document# or 9. Does the site contain a brook, body of water or wetlands? NO JPQ DON'T KNOW 0 YES 0 IF YES, does a permit need to be obtained or has a permit been obtained from the Conservation Commission? A permit needs to be obtained 0 A permit has been obtained 0 and was issued: 000.pdf File#MP-2005-0105 APPLICANT/CONTACT PERSON Wright Builders ADDRESS/PHONE 48 Bates St (413)586-8287 PROPERTY LOCATION 32 NORTHERN AVE MAP 25C PARCEL 027 001 ZONE URB THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FO LLED OUT 0 4q 41=0 Fee Paid Building,Permit Filled out - Fee Paid Typeof Construction: ZPA-2 STORY FRONT ADDITION New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included• Owner/Statement or License 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESENTED: Approved additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER: § Intermediate Project: Site Plan AND/OR Special Permit with Site Plan Major Project: Site Plan AND/OR Special Permit with Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § 913 Finding ►/ Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street C ssion Signature of Building Official Date Note:Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact the Office of Planning&Development for more information. C� /1 BP-2005-1082 32 NORTHERN AVE COMMONWEALTH OF MASSACHUSETTS GIs#: CITY OF NORTHAMPTON M Block: 25C-027 Lot: -001 Permit BUildinQ BUILDING PERMIT Category- ADDITION Permit# BP-2005-1082 Project# IS-2005-1225 Est.Cost: $170793.00 FPP'.X864.00 PERMISSION IS HEREBY GRANTED TO: License: Consc class: Contractor: 068185 use Group: Wright Builders T Size(sq. fr j• 17511.12 Owner: HATHAWAY STEPHEN B &MARIE dnnlirant• Wright Builders Zoning:U1tB ` AT: 32 NORTHERN AVE Insurance: Phone: --'Workers Compensation Applicant Address: 413 586-8287 48 Bates St 8 Bates MPTONMA01060 ISSUED ON:S/16/05 0:00:00 TO PERFORM THE FOLLOWING WORK:CONSTRUCT 2 STORY MUDROOM ADDITION, 1 STORY(FAM RM), 2 STORY BUMPOUT & NEW DECK POST THIS CARD SO IT IS VISIBLE FROM D.P.W.T E STREET Building Inspector Inspector of Plumbing Inspector of Wiring Service: , Meter: Underground: 41 C1 Footings: luse# Foundation: Rough: Rough:�/�3 f 0 -1/� Driveway Final: A,�f�1 Final: Final: (o V9W) Rough Frame:© l�r Fireplace/Chimney: Gas: Fire ar ment _ Insulation:'f k Rough: ���►�'0� PILI.• Final: a K COIJ-rl N at-aT Final:/�(-�� � , Smoke: 0 1 1 2?l e 6 L o A I S THIS PERMIT MAY BE REVOKED BY CITY OF NORTHAMPTON UPON VIOLAT1 OF ANY OF ITS RULES AND REGULATIO Si nature: Certificate Of Occu an Date Paid: Amount: FeeTyRE Building 5/16/05 0:00:00 $864.00 212 Main Street,Phone(413) 587-1240,Fax: (413)587-1272 Building Commissioner-Anthony Patillo