25-015 (38) ■ 142 Po1p1n NnrihOmpmn MA 41 564 5775 s FEB 1 2 1998 ,► MOCONS Assgcishs c February t�,1 x)97 Richard Gusto Architecture 72 Boynton Rd S Deerfield Ma 613 73 160WIr,Yv Mef",le Nf AAA. RE Airport Storage building Flood control issues Dear Dick, Interior boAgn The project drawings Al ,fit A2 show the WAD construction method and the anchoring means to enable this building to both produce a minimurn or flood dispersion in addition to having both tk means.to prevent dislodging of the structure and an inability to even f1bat without being totally reduced to a loose pile of material. The floor and roof trusses arc well above the lower level where only a concrete slab exists. The building would not.float if torn from the anchors as it has no lower floor to create buoyancy, The anchors are sufficient to wig the type and velocity of flood waters that could reach the building. As long as titie'diagwW bracing in created as drawn,the building will withstand the horizoaW water pressure over S fcGt above slab level. The volume of weer dispersion rni 00 4UO to the fact that the wall materials including the insulation are taxi'.' wall will t311 up with Nvatcr leaving the displacement to only the plywood sheet rock and sitting, thicknesses that are below a potential want level. The amount is +-28 stl ft. of area and it dwefore=28 cu. it. for awry foot ofwatet depth above slab in its displacement. If you need any more help please.call. Sincerely, Tris Metcalfe