25A-185 (123) ALLIED TESTING LABORATORIES, INC. 115 St. George Road •Springfield, Massachusetts 01 104 Phone: (41.3) 736-1846 Report No. 1 of Soils Tests Date: 1/30/95 Client: Facilities Constructors, Inc. Project: Coca Cola tottling and Distribution Center, Northampton, MA Subject: Soils Tests Reported to: Facilities Constructors, Inc. - Att: Mr. John Newton Inspector on site this date at request of client's representative for review of specifications and proposed compaction tests. No tests taken this date. ' i Lb 01995 n Respectfully submitted, ALLIED TESTING LABORATORIES, INC. By: Chester V. Dawicki Director of Testing Services Copy: Mr. Anthony Patillo, Northampton Bldg. Dept. Mr. Charles Sherrill, Coca Cola Construction Site MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S. C7- w ALLIED TESTING LABORATORIES, INC. 115 St. George Road •Springfield, Massachusetts 01 104 Phone: (4 13) 736-1846 Report No. 2 of Soils Tests Date: 2/6/95 Client: Facilities Constructors, Inc. Project: Coca Cola Bottling and Distribution Center, Northampton, MA Subject: Soils Tests Reported to: Facilities Constructors, Inc. — Att: Mr. John Newton Inspector on site this date for scheduled soil tests; all work cancelled due to snowfall. Concrete scheduled for P.M. also postponed. Respectfully submitted, ALLIED TESTING LABORATORIES, INC.1 By: Chester V. Dawicki Director of Testing Services Copy: Mr. Anthony Pati.11o, Northampton Bldg. Dept. Mr. Charles Sherrill, Coca Cola Construction Site MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S. ALLIED TESTING LABORATORIES, INC. 1 1 S St. George Road • Springfield, Massachusetts 01 104 Phone: (413) 736-1846 f CONCRETE FIELD REPORT N0. 1 DATE ; 9/95�--- � B � � •�,� M Client: Facilities Constructors, Inc. Project: Coca-Cola Bottling & Distribution Center, Northam to Contractor: DOS Concrete DE OFSUILO;1 NORTHAMPTON MA 01060 Producer: Construction Service Location of Concrete Placement: Piers on line WH-WJ W4, W5, W6 Reported to: Facilities Constructors, Inc. - Att: Mr. John Newton CYLINDER FABRICATION DATE CAST: 2/9/95 IDENTIFICATION TIME TRUCK CLASS SLUMP EXACT LOCATION A,B,C,D 13:30 144 3000 3 1/2" Piers on line WH-WJ W4,W5,W6 SLUMP TESTS TEMPERATURES AIR CONTENT Time Truck Slump Air Temp. Conc. Temp. % Air 11:00 252 2 3/4" 30°F 56°F 4.2 13:30 144 3 1/2" 32°F 52°F 5.0 REMARKS: Rebar installed as required on Drawing #ROl Weather: sunny/cold Respectfully submitted, ALLIED TESTING LABORATORIES, INC. 6"11.f '�''�Z', By: Chester V. Dawicki Director of Testing Services Copy: Mr. Anthony Patillo, City of Northampton Bldg. Dept. Mr. Charles Sherrill, Coca Cola Construction Site MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S. ALLIED TESTING LABORATORIES,- 115 St. George Road •Springfield, Massachusetts 01 kl ,. , Phone: (41-33) 736-1846 FEB 1 4 W15 Report No. 4 of Soils Tests Date: 95 P � Client: Facilities Constructors, Inc. DEPT OF8UI4.M IGf4�` Project: Coca Cola Bottling and Distribution Center, Northa UO A�PTG": A1A03C'" —~ Subject: Soils Tests Reported to: Facilities Constructors, Inc. - Att: Mr. John Newton TEST: DENSITY OF SOIL IN PLACE BY NUCLEAR METHOD - ASTM D2922 TEST DRY MOISTURE MAXIMUM NO. LOCATION DENSITY CONTENT DENSITY COMPACTION (Pcf) (:.) (Pcf) BELOW INTERIOR FOOTINGS 1 Line WJ-W4 102.6 12..4 104.2 98.6 2 Line WJ-W5 101.6 15.0 104.2 97.5 3 Line WJ-W6 101.4 12:.8 104.2 97.3 4 Line WH-W4 100.8 14.3 104.2 96.7 5 LIne WH-W5 101.5 11.9 104.2 97.4 6 Line WH-W6 102.2 12.3 104.2 98.1 Respectfully submitted, ALLIED TESTING LABORATORIES, INC. - G1 By: Chester V.. Dawicki Director of Testing Services Copy: Mr. Anthony Patillo, Northampton Bldg. Dept. Mr. Charles Sherrill, Coca Cola Construction Site MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S. ALLIED TESTING LABORATORIES, INC. 115 St. George Road • Springfield, Massachusetts 01 104 Phone: (413) 736-1846 Report No. 3 of Soils Tests Date: 2/9/95 Client: Facilities Constructors, Inc. Project: Coca Cola Bottling and Distribution Center, Northampton, MA Subject: Soils Tests Reported to: Facilities Constructors, Inc. - Att: Mr. John Newton TEST: SIEVE ANALYSIS (WASHED METHOD) ` I Lab. No. 6063 6064 6 Sieve No. % Passing % Passing FEB 1 41995. 1/2 100.0 ----�--� DEPT OF 131l!;F,itr c 1/4 99.5 3/8 99.5 4 99.2 8 100.0 97.3 16 99.9 93.0 30 99.9 89.0 50 80.4 86.4 100 34.1 83.8 200 28.0 72.2 TEST: MOISTURE/DENSITY RELATIONSHIP OF SOILS TEST -- ASTM D1557 I.ab. No. 6063 6064 Maximum Dry Unit Weight: (pcf) 104.2 101.1 Optimum Water Content: (7) 15.8 18.2 IDENTIFICATION: Lab. No. 6063 - On site material below interior column bases (Tan) Lab. No. 6064 - On site material below interior column bases (Brown) Respectfully :submitted, ALLI,JE�D TESTING LABORATORIES, INC. By: Chester V. Dawicki Director of Testing Services Copy: Mr. Anthony Patillo, Northampton Bldg. Dept. Mr. Charles Sherrill, Coca Cola Construction Site MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S. ALLIED TESTING LABORATORIES, INC. 115 St. George Road •Springfield, Massachusetts 01 104 Phone: (413) 736-1846 �i Report No. 5 of Soils Tests Datef.� /10/95 Client: Facilities Constructors, Inc. Project: Coca Cola Bottling and Distribution Center, North m - G Subject: Soils Tests m�N0`�"rP.RI�a� RlA016^:i) Reported to: Facilities Constructors, Inc. - Att: Mr. John Newton TEST: SIEVE ANALYSIS Lab. No. 6068 Sieve No. % Passing 1 1/2 100.0 1 97.8 3/4 84.6 3/8 75.1 4 67.6 8 58.9 16 45.5 30 21.9 50 8.3 100 3.9 200 2.1 TEST: MOISTURE/DENSITY RELATIONSHIP OF SOILS TEST - ASTM D1557 Lab. No. 6068 Maximum Dry Unit Weight: 122.8 pcf Optimum Water content: 8.8% Identification: Lab. No. 6068 - Warner Brothers backfill around interior column. Respectfully submitted, ALLIED TESTING LABORATORIES, INC. i By: Chester V. Dawicki Director of Testing Services Copy: Mr. Anthony Patillo, Northampton Bldg. Dept. Mr. Charles Sherrill, Coca Cola Construction Site MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S. ALLIED TESTING LABORATORIES,_ INC. r 115 St. George Road •Springfield, Massachusetts 01 104 I Phone: (413) 736-1846 Report No. 6 of Soils Tests Date:Clie nt: Facilities Constructors, Inc. Project: Coca Cola Bottling and Distribution Center, Northam t AMPT AMPTU�1 Subject: Soils Tests Reported to: Facilities Constructors, Inc. - Att: Mr. John Newton TEST: DENSITY OF SOIL IN PLACE BY NUCLEAR METHOD, - ASTM D2922 TEST DRY MOISTURE MAXIMUM NO. LOCATION DENSITY CONTENT DENSITY COMPACTION (pcf) (I) (pcf) (7.) BEL014 INTERIOR FOOTINGS 1 Line WG-W4 102.8 11.7 104.2 98.6 2 Line WG-W5 100.4 13.1 104.2 96.3 3 Line WG-W6 101.5 13.7 104.2 97.4 4 Line WF-W4 102.5 11. 2 104.2 98.4 5 Line WF-W5 103.0 13.2 104.2 98.8 6 Line WF-W6 101.1 13.0 104.2 97.0 7 Line WE-W5 100.8 11. 7 104.2 96.7 8 Line WE-W6 102.6 12.9 104.2 98.5 BACKFILL AROUND INTERIOR FOOTINGS 9 Line WJ-W4 118.8 4.9 122.8 96.7 10 Line WJ-W5 120.1 4. 6 122.8 97.8 11 Line WJ-W6 119.4 3.4 122.8 97.2 Respectfully submitted, ALLIED TESTING LABORATORIES, INC. By: Chester V. Daw:icki Director of Testing Services Copy: Mr. Anthony Patillo, Northampton Bldg. Dept. Mr. Charles Sherrill, Coca Cola Construction Site MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S. ALLIED TESTING LABORATORIES, INC. 115 St. George Road •Springfield, Massachusetts 011.04 Phone: (413) 736-1846 1 CONCRETE FIELD REPORT NO. 2 DATE /10/95 Client: Facilities Constructors, Inc. DEPT OFBUILOItdGIiU°„ ANORT , �APTO! m" Project: Coca-Cola Bottling & Distribution Center, Northa rt Contractor: DOS Concrete Producder: Construction Service Location of Concrete Placement: Interior column footings Reported to: Facilities Constructors, Inc. - Att: Mr. John Newton DATE CAST: 2/10/95 IDENTIFICATION TIME TRUCK CLASS SLUMP EXACT LOCATION A,B,C,D 11:15 245 3000 2 1/2" Interior column footings WG-WF, W4-W5-W6 We-W5-W6 SLUMP TESTS TEMPERATURES AIR CONTENT Time Truck Slump Air Temp. Conc. Temp. % Air 11:15 245 2 1/2" 30°F 52°F 4.0 13:30 245 3 1/2" 56°F 5.6 Weather: sunny/cold Temp: 30° No. Yds:39 Respectfully submitted, ALLIED TESTING LABORATORIES, INC. By: Chester V. Dawicki Director of Testing Services Copy: Mr. Anthony Patillo, City of Northampton Bldg. Dept. Mr. Charles Sherrill, Coca Cola Construction Site MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.O.B. / I.A.C.R.S. ALLIED TESTING LABORATORIES, INC. 115 St. George Road •Springfield, Massachusetts 01 104 Phone: (413) 736-1846 Report No. 8 of Soils Tests Date: 2/14/95 Client: Facilities Constructors, Inc. Project: Coca Cola Bottling and Distribution Center, Northampton, MA Subject: Soils Tests Reported to: Facilities Constructors, Inc. - Att: Mr. John Newton TEST: DENSITY OF SOIL IN PLACE BY NUCLEAR METHOD - ASTM D2922 TEST DRY MOISTURE MAXIMUM NO. LOCATION DENSITY CONTENT DENSITY COMPACTION (pcf) (Pcf) BELOW INTERIOR COLUMN FOOTINGS 1 Line WE-W4 100.6 13. 7 104.2 96.5 2 Line WD-W4 101.1 15.1 104.2 97.0 3 Line WD-W5 99.8 15.2 104.2 95.8 4 Line WD-W6 100.4 14.3 104.2 96.3 5 Line WC-W4 100.2 13.4 104.2 96.2 6 Line WC-W5 101.4 11.0 104.2 97.3 7 Line WC-W6 100.8 14.7 104.2 96.7 8 Line WK-W6 102.0 1_5.2 104.2 97.9 9 Line WK-W5 99.9 14. 7 104.2 95.9 10 Line WK-W4 1.00.1 13.3 104.2 96.1 Respectfully submitted, s ALLIED TESTING LABORATORIES, INC. 6 A5 By: Chester V. Dawicki Director of Testing Services Copy: Mr. Anthony Patillo, Northampton Bldg. Dept. Mr. Charles Sherrill, Coca Cola Construction Site MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S. now ALLIED TESTING LABORATORIES, INC. 1 15 St. George Road •Springfield, Massachusetts 01 104 Phone: (413) 736-1846 CONCRETE FIELD REPORT NO. 3 DATE: 2/14/95 Client: Facilities Constructors, Inc. Project: Coca-Cola Bottline & Distribution Center, Northampton, MA Contractor: DOS Concrete Producer: Construction Service Location of Concrete Placement: Interior column footings Reported to: Facilities Constructors, Inc. - Att: Mr. John Newton CYLINDER FABRICATION DATE CAST: 2/14/95 IDENTIFICATION TIME TRUCK CLASS SLUMP EXACT LOCATION A,B,C,D _ 3000 2 1/2" Interior column footings WE-W4, WD-W4, W5, W6, W6-W4, W5, W6, - WK-W6, W5, W4 6 l9 t } DEPT OF 8s SLUM? TEffrT- TEMPERATURES AIR CONTENT Time Truck Slump Air Temp. COi1C. Temp % Air 10:30 124 3" 25 0F 52°F 4.0 11:45 254 2J" 52°F 4.8 Weather: sunny/cold Respectfully submitted, ALLIED TESTING LABORATORIES, INC. wok v,4w.a4.- By: Chester V. Dawicki Director of Testing Services Copy: Mr. Anthony Patillo, City of Northampton Bldg. Dept. Mr. Charles Sherrill, Coca Cola Construction Site MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S. — Iwo ALLIED TESTING LABORATORIES, INC. Road o S Massachusetts 01 104 1I 5 St. George Ro Springfield,p g Phone: (413) 736-1846 Report No. 7 of Soils Tests Date: 2/13/95 Client: Facilities Constructors, Inc. Project: Coca Cola Bottling and Distribution Center, Northampton, MA Subject: Soils Tests Reported to: Facilities Constructors, Inc. - Att: Mr. John Newton TEST: DENSITY OF SOIL IN PLACE BY NUCLEAR METHOD - ASTM D2922 TEST DRY MOISTURE MAXIMUM NO. LOCATION DENSITY CONTENT DENSITY COMPACTION (pcf) (%) (Pcf) BACKFILL AROUND INTERIOR COLUMN FOOTING 1 W'-4,F 121..8 3. 8 122.8 99.2 2 W5-WF r? 119.8 4.0 122.8 97.5 3 W6-WF G k; 119.2 3. 9 122.8 97.1 6 1995 4 WE-W6 } 1?0.8 3. 6 122.8 98.4 t 5 WE-W5 w� f�' ' '�119.6 3. 8 122.8 97.4 6 W(.,-W4 118.8 3..5 122.8 96.7 7 WG-W5 119.0 6..0 122.8 96.9 Respectfully submitted, ALLIED TESTING LABORATORIES, INC. By: Chester V. Dawicki Director of Testing Services Copy: Mr. Anthony Patillo, Northampton Bldg. Dept. Mr. Charles Sherrill, Coca Cola Construction Site MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S. MW