25A-185 (123) ALLIED TESTING LABORATORIES, INC.
115 St. George Road •Springfield, Massachusetts 01 104
Phone: (41.3) 736-1846
Report No. 1 of Soils Tests Date: 1/30/95
Client: Facilities Constructors, Inc.
Project: Coca Cola tottling and Distribution Center, Northampton, MA
Subject: Soils Tests
Reported to: Facilities Constructors, Inc. - Att: Mr. John Newton
Inspector on site this date at request of client's representative for review of
specifications and proposed compaction tests.
No tests taken this date. '
i Lb 01995
n
Respectfully submitted,
ALLIED TESTING LABORATORIES, INC.
By: Chester V. Dawicki
Director of Testing Services
Copy:
Mr. Anthony Patillo, Northampton Bldg. Dept.
Mr. Charles Sherrill, Coca Cola Construction Site
MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S.
C7- w ALLIED TESTING LABORATORIES, INC.
115 St. George Road •Springfield, Massachusetts 01 104
Phone: (4 13) 736-1846
Report No. 2 of Soils Tests Date: 2/6/95
Client: Facilities Constructors, Inc.
Project: Coca Cola Bottling and Distribution Center, Northampton, MA
Subject: Soils Tests
Reported to: Facilities Constructors, Inc. — Att: Mr. John Newton
Inspector on site this date for scheduled soil tests; all work cancelled due to
snowfall. Concrete scheduled for P.M. also postponed.
Respectfully submitted,
ALLIED TESTING LABORATORIES, INC.1
By: Chester V. Dawicki
Director of Testing Services
Copy:
Mr. Anthony Pati.11o, Northampton Bldg. Dept.
Mr. Charles Sherrill, Coca Cola Construction Site
MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S.
ALLIED TESTING LABORATORIES, INC.
1 1 S St. George Road • Springfield, Massachusetts 01 104
Phone: (413) 736-1846
f
CONCRETE FIELD REPORT N0. 1 DATE ; 9/95�---
� B � � •�,� M
Client: Facilities Constructors, Inc.
Project: Coca-Cola Bottling & Distribution Center, Northam to
Contractor: DOS Concrete DE OFSUILO;1
NORTHAMPTON MA 01060
Producer: Construction Service
Location of Concrete Placement: Piers on line WH-WJ W4, W5, W6
Reported to: Facilities Constructors, Inc. - Att: Mr. John Newton
CYLINDER FABRICATION
DATE CAST: 2/9/95
IDENTIFICATION TIME TRUCK CLASS SLUMP EXACT LOCATION
A,B,C,D 13:30 144 3000 3 1/2" Piers on line WH-WJ W4,W5,W6
SLUMP TESTS TEMPERATURES AIR CONTENT
Time Truck Slump Air Temp. Conc. Temp. % Air
11:00 252 2 3/4" 30°F 56°F 4.2
13:30 144 3 1/2" 32°F 52°F 5.0
REMARKS:
Rebar installed as required on Drawing #ROl
Weather: sunny/cold
Respectfully submitted,
ALLIED TESTING LABORATORIES, INC.
6"11.f '�''�Z',
By: Chester V. Dawicki
Director of Testing Services
Copy:
Mr. Anthony Patillo, City of Northampton Bldg. Dept.
Mr. Charles Sherrill, Coca Cola Construction Site
MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S.
ALLIED TESTING LABORATORIES,-
115 St. George Road •Springfield, Massachusetts 01 kl ,. ,
Phone: (41-33) 736-1846
FEB 1 4 W15
Report No. 4 of Soils Tests Date: 95
P �
Client: Facilities Constructors, Inc. DEPT OF8UI4.M IGf4�`
Project: Coca Cola Bottling and Distribution Center, Northa UO A�PTG": A1A03C'" —~
Subject: Soils Tests
Reported to: Facilities Constructors, Inc. - Att: Mr. John Newton
TEST: DENSITY OF SOIL IN PLACE BY NUCLEAR METHOD - ASTM D2922
TEST DRY MOISTURE MAXIMUM
NO. LOCATION DENSITY CONTENT DENSITY COMPACTION
(Pcf) (:.) (Pcf)
BELOW INTERIOR FOOTINGS
1 Line WJ-W4 102.6 12..4 104.2 98.6
2 Line WJ-W5 101.6 15.0 104.2 97.5
3 Line WJ-W6 101.4 12:.8 104.2 97.3
4 Line WH-W4 100.8 14.3 104.2 96.7
5 LIne WH-W5 101.5 11.9 104.2 97.4
6 Line WH-W6 102.2 12.3 104.2 98.1
Respectfully submitted,
ALLIED TESTING LABORATORIES, INC.
- G1
By: Chester V.. Dawicki
Director of Testing Services
Copy:
Mr. Anthony Patillo, Northampton Bldg. Dept.
Mr. Charles Sherrill, Coca Cola Construction Site
MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S.
ALLIED TESTING LABORATORIES, INC.
115 St. George Road • Springfield, Massachusetts 01 104
Phone: (413) 736-1846
Report No. 3 of Soils Tests Date: 2/9/95
Client: Facilities Constructors, Inc.
Project: Coca Cola Bottling and Distribution Center, Northampton, MA
Subject: Soils Tests
Reported to: Facilities Constructors, Inc. - Att: Mr. John Newton
TEST: SIEVE ANALYSIS (WASHED METHOD) ` I
Lab. No. 6063 6064 6
Sieve No. % Passing % Passing FEB 1 41995.
1/2 100.0 ----�--�
DEPT OF 131l!;F,itr c
1/4 99.5
3/8 99.5
4 99.2
8 100.0 97.3
16 99.9 93.0
30 99.9 89.0
50 80.4 86.4
100 34.1 83.8
200 28.0 72.2
TEST: MOISTURE/DENSITY RELATIONSHIP OF SOILS TEST -- ASTM D1557
I.ab. No. 6063 6064
Maximum Dry Unit Weight: (pcf) 104.2 101.1
Optimum Water Content: (7) 15.8 18.2
IDENTIFICATION:
Lab. No. 6063 - On site material below interior column bases (Tan)
Lab. No. 6064 - On site material below interior column bases (Brown)
Respectfully :submitted,
ALLI,JE�D TESTING LABORATORIES, INC.
By: Chester V. Dawicki
Director of Testing Services
Copy:
Mr. Anthony Patillo, Northampton Bldg. Dept.
Mr. Charles Sherrill, Coca Cola Construction Site
MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S.
ALLIED TESTING LABORATORIES, INC.
115 St. George Road •Springfield, Massachusetts 01 104
Phone: (413) 736-1846
�i
Report No. 5 of Soils Tests Datef.� /10/95
Client: Facilities Constructors, Inc.
Project: Coca Cola Bottling and Distribution Center, North m -
G
Subject: Soils Tests m�N0`�"rP.RI�a� RlA016^:i)
Reported to: Facilities Constructors, Inc. - Att: Mr. John Newton
TEST: SIEVE ANALYSIS
Lab. No. 6068
Sieve No. % Passing
1 1/2 100.0
1 97.8
3/4 84.6
3/8 75.1
4 67.6
8 58.9
16 45.5
30 21.9
50 8.3
100 3.9
200 2.1
TEST: MOISTURE/DENSITY RELATIONSHIP OF SOILS TEST - ASTM D1557
Lab. No. 6068
Maximum Dry Unit Weight: 122.8 pcf
Optimum Water content: 8.8%
Identification:
Lab. No. 6068 - Warner Brothers backfill around interior column.
Respectfully submitted,
ALLIED TESTING LABORATORIES, INC.
i
By: Chester V. Dawicki
Director of Testing Services
Copy:
Mr. Anthony Patillo, Northampton Bldg. Dept.
Mr. Charles Sherrill, Coca Cola Construction Site
MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S.
ALLIED TESTING LABORATORIES,_ INC. r
115 St. George Road •Springfield, Massachusetts 01 104 I
Phone: (413) 736-1846
Report No. 6 of Soils Tests Date:Clie nt: Facilities Constructors, Inc.
Project: Coca Cola Bottling and Distribution Center, Northam t AMPT AMPTU�1 Subject: Soils Tests Reported to: Facilities Constructors, Inc. - Att: Mr. John Newton
TEST: DENSITY OF SOIL IN PLACE BY NUCLEAR METHOD, - ASTM D2922
TEST DRY MOISTURE MAXIMUM
NO. LOCATION DENSITY CONTENT DENSITY COMPACTION
(pcf) (I) (pcf) (7.)
BEL014 INTERIOR FOOTINGS
1 Line WG-W4 102.8 11.7 104.2 98.6
2 Line WG-W5 100.4 13.1 104.2 96.3
3 Line WG-W6 101.5 13.7 104.2 97.4
4 Line WF-W4 102.5 11. 2 104.2 98.4
5 Line WF-W5 103.0 13.2 104.2 98.8
6 Line WF-W6 101.1 13.0 104.2 97.0
7 Line WE-W5 100.8 11. 7 104.2 96.7
8 Line WE-W6 102.6 12.9 104.2 98.5
BACKFILL AROUND INTERIOR FOOTINGS
9 Line WJ-W4 118.8 4.9 122.8 96.7
10 Line WJ-W5 120.1 4. 6 122.8 97.8
11 Line WJ-W6 119.4 3.4 122.8 97.2
Respectfully submitted,
ALLIED TESTING LABORATORIES, INC.
By: Chester V. Daw:icki
Director of Testing Services
Copy:
Mr. Anthony Patillo, Northampton Bldg. Dept.
Mr. Charles Sherrill, Coca Cola Construction Site
MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S.
ALLIED TESTING LABORATORIES, INC.
115 St. George Road •Springfield, Massachusetts 011.04
Phone: (413) 736-1846 1
CONCRETE FIELD REPORT NO. 2 DATE /10/95
Client: Facilities Constructors, Inc. DEPT OFBUILOItdGIiU°„
ANORT , �APTO! m"
Project: Coca-Cola Bottling & Distribution Center, Northa rt
Contractor: DOS Concrete
Producder: Construction Service
Location of Concrete Placement: Interior column footings
Reported to: Facilities Constructors, Inc. - Att: Mr. John Newton
DATE CAST: 2/10/95
IDENTIFICATION TIME TRUCK CLASS SLUMP EXACT LOCATION
A,B,C,D 11:15 245 3000 2 1/2" Interior column footings WG-WF,
W4-W5-W6
We-W5-W6
SLUMP TESTS TEMPERATURES AIR CONTENT
Time Truck Slump Air Temp. Conc. Temp. % Air
11:15 245 2 1/2" 30°F 52°F 4.0
13:30 245 3 1/2" 56°F 5.6
Weather: sunny/cold
Temp: 30°
No. Yds:39
Respectfully submitted,
ALLIED TESTING LABORATORIES, INC.
By: Chester V. Dawicki
Director of Testing Services
Copy:
Mr. Anthony Patillo, City of Northampton Bldg. Dept.
Mr. Charles Sherrill, Coca Cola Construction Site
MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.O.B. / I.A.C.R.S.
ALLIED TESTING LABORATORIES, INC.
115 St. George Road •Springfield, Massachusetts 01 104
Phone: (413) 736-1846
Report No. 8 of Soils Tests Date: 2/14/95
Client: Facilities Constructors, Inc.
Project: Coca Cola Bottling and Distribution Center, Northampton, MA
Subject: Soils Tests
Reported to: Facilities Constructors, Inc. - Att: Mr. John Newton
TEST: DENSITY OF SOIL IN PLACE BY NUCLEAR METHOD - ASTM D2922
TEST DRY MOISTURE MAXIMUM
NO. LOCATION DENSITY CONTENT DENSITY COMPACTION
(pcf) (Pcf)
BELOW INTERIOR COLUMN FOOTINGS
1 Line WE-W4 100.6 13. 7 104.2 96.5
2 Line WD-W4 101.1 15.1 104.2 97.0
3 Line WD-W5 99.8 15.2 104.2 95.8
4 Line WD-W6 100.4 14.3 104.2 96.3
5 Line WC-W4 100.2 13.4 104.2 96.2
6 Line WC-W5 101.4 11.0 104.2 97.3
7 Line WC-W6 100.8 14.7 104.2 96.7
8 Line WK-W6 102.0 1_5.2 104.2 97.9
9 Line WK-W5 99.9 14. 7 104.2 95.9
10 Line WK-W4 1.00.1 13.3 104.2 96.1
Respectfully submitted,
s ALLIED TESTING LABORATORIES, INC.
6 A5
By: Chester V. Dawicki
Director of Testing Services
Copy:
Mr. Anthony Patillo, Northampton Bldg. Dept.
Mr. Charles Sherrill, Coca Cola Construction Site
MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S.
now
ALLIED TESTING LABORATORIES, INC.
1 15 St. George Road •Springfield, Massachusetts 01 104
Phone: (413) 736-1846
CONCRETE FIELD REPORT NO. 3 DATE: 2/14/95
Client: Facilities Constructors, Inc.
Project: Coca-Cola Bottline & Distribution Center, Northampton, MA
Contractor: DOS Concrete
Producer: Construction Service
Location of Concrete Placement: Interior column footings
Reported to: Facilities Constructors, Inc. - Att: Mr. John Newton
CYLINDER FABRICATION
DATE CAST: 2/14/95
IDENTIFICATION TIME TRUCK CLASS SLUMP EXACT LOCATION
A,B,C,D _ 3000 2 1/2" Interior column footings WE-W4,
WD-W4, W5, W6, W6-W4, W5, W6,
- WK-W6, W5, W4
6 l9
t
} DEPT OF 8s
SLUM? TEffrT- TEMPERATURES AIR CONTENT
Time Truck Slump Air Temp. COi1C. Temp % Air
10:30 124 3" 25 0F 52°F 4.0
11:45 254 2J" 52°F 4.8
Weather: sunny/cold
Respectfully submitted,
ALLIED TESTING LABORATORIES, INC.
wok v,4w.a4.-
By: Chester V. Dawicki
Director of Testing Services
Copy:
Mr. Anthony Patillo, City of Northampton Bldg. Dept.
Mr. Charles Sherrill, Coca Cola Construction Site
MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S.
— Iwo ALLIED TESTING LABORATORIES, INC.
Road o S Massachusetts 01 104
1I 5 St. George Ro Springfield,p g
Phone: (413) 736-1846
Report No. 7 of Soils Tests Date: 2/13/95
Client: Facilities Constructors, Inc.
Project: Coca Cola Bottling and Distribution Center, Northampton, MA
Subject: Soils Tests
Reported to: Facilities Constructors, Inc. - Att: Mr. John Newton
TEST: DENSITY OF SOIL IN PLACE BY NUCLEAR METHOD - ASTM D2922
TEST DRY MOISTURE MAXIMUM
NO. LOCATION DENSITY CONTENT DENSITY COMPACTION
(pcf) (%) (Pcf)
BACKFILL AROUND INTERIOR COLUMN FOOTING
1 W'-4,F 121..8 3. 8 122.8 99.2
2 W5-WF r? 119.8 4.0 122.8 97.5
3 W6-WF G k; 119.2 3. 9 122.8 97.1
6 1995
4 WE-W6 } 1?0.8 3. 6 122.8 98.4
t
5 WE-W5 w� f�' ' '�119.6 3. 8 122.8 97.4
6 W(.,-W4 118.8 3..5 122.8 96.7
7 WG-W5 119.0 6..0 122.8 96.9
Respectfully submitted,
ALLIED TESTING LABORATORIES, INC.
By: Chester V. Dawicki
Director of Testing Services
Copy:
Mr. Anthony Patillo, Northampton Bldg. Dept.
Mr. Charles Sherrill, Coca Cola Construction Site
MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S.
MW