Loading...
25A-185 (39) ALLIED TESTING LABORATORIES, INC. 115 St. George Road • Springfield,Massachusetts 01 104 fjG Phone. (41 s) 735-' 845 Fax: (4I 3) 735-!538 Report No. 1 of Soils Tests Date: 9113106 Client: Coca-Cola North America Project: Coca-Cola 'north America, Hot Fill Line Addityor, Northampton, AiA Subject: Soils Tests Reported to: Coca-Cola jiorth America - Attention: Mr. Gary Carlo*.o Here:oith is submitted, the results of sous tests conducted oa material site proposed for use at the above noted project. sample picked up on bu Allied personnel on 9j2 106. Lab. No. 8574- Source,'dentif'cation: Or. Site Stockpile TEST: IOLSTUREIDEivSITY RELATIONSHIP of SOILS TEST - ASTM D1557 Maximum Dry Unit weight: 113.8 pcf pptimut Water Content: 14.0 . 7 Respectfully submitted, ALLIED TESTING LABOP.ATORTES, INC. Bu: Richard Bellucci president WEVBER: ;.S.T M. A.C.L �' ANV.S. f rVS.N.7. ALLIED TESTING LABORATORIES, INC. 1 15 5t. George Road * Springfield,Massachusettts 01 104 Phone: (413) 736-1846 Fax (413) 736-1838 CONCRETE FIELD REPORT 1O. 4 DATE: 09/12/06 Client: Coca-Cola North America Project: Coca-Cola North America Hot Fill Line Addition, Northampton, MA Contractor: Hickson Producer: Construction Service Location of Concrete Placement: Lower Footing Truckers Lounge and Chiller Platform Piers Coca--Cola North America Reported to: Attention: sir. Cary Carlow CYLINDER FABRICATION - ASTIH C31 DATE CAST: 09/12/06 IDENTIFICATION TIME TRUCK CLASS IsiVIUMP EXACT LOCATION A,B,C,D 14:15 269 4500 0- " Lower Footing Truckers Lounge and i er Platform Piers SLUMP TESTS - ASTM C143 AIR CONTENT TESTS -- ASTM C173 or C231 Time Truck Slump Time Truck No. Air Content M 14:15 269 3" 14:15 269 5.6% AMBIEtiT TEMPERATURE CONCRETE TEMPERATURE - ASTM C1064 Time Temperature Time Truck loo. Temperature 14:15 71°F 14:15 269 79°F REINFORCING INSPECTION Reinforcing incorporated in today's concrete placement was found to be satisfactory for size, quantity, cleanliness, properly supported., adequately tied and spaced as required.in accordance with Drawing No. S1.2 REMARKS: 8 #6 with 7";4 C12 Ties (Piers) (Footing) 2 7'7'5 Continous. Weather: Clear Temp. : 70's Respectfully submitted, No. Yds. : 71 ALLIED TESTIJC: LABORATORIES, TNC. By: Richard Bellucci President MEMBER: A..S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. I I.A.C.R.S. ALLIED TESTING LABORATORIES, INC. l 15 St.George Road & Springfield,Massachusetts 01 104 Phone: (413) 736-1845 Fox: (4 13) 736-1838 CONCRETE FIELD REPORT NO. 3 DATE: 09/13/06 Client: Coca-Cola North America Project: Coca-Cola North America Hot Fill Line Addition, Northampton, AA Contractor: Hickson Producer: Construction Service Location of Concrete Placement: Truckers Lounge Walls Coca-Cola North America Reported to: Attention: Mr. Cary Carlow CYLINDER FABRICATION ASTM C31 DATE CAST: 09/13/06 IDENTIFICATION TIME TRUCK CLASS EXACT LOCATION A,B,C,D 15:00 273 4500 5" Truckers Lounge Walls SLUMP TESTS - ASTMI C143 AIR CONTENT TESTS - ASTM C173 or C231 Time Truck Slump Time Truck No. Air Content (�} 15:00 273 5" 15:00 273 5.57 A_`iBIENT TEMPERATURE CONCRETE TEMPERATURE - ASTM C1064 Time Temperature Time Truck No. Temperature 15:00 70°F 15:00 273 72°F REINFORCING INSPECTION Reinforcing incorporated in today' s concrete placement was found to be satisfactory for size, quantity, cleanliness, properly supported, adequately tied and spaced as required in accordance with Drawing No. 12 on S1.2 Weather: Cloudy Temp. : 70's No. Yds. : 3 Respectfully submitted, ALLIED TESTING LABORATORIES, INC. By: Richard Bellucci President M MBER.: A.S.T.M f A.C.I. J A.W.S. A.S.N.T. / M.C.I.B. / 1.A.C.2.S. ALLIED TESTING LABORATORIES, INC. 1 15 St. George Road • Springfield,f Iassachusetts 01 104 Phone: (4 13) 736-i 846 Fax: (4I 3) 736-I S38 CONCRETE FIELD REPORT NO. 2 DATE: 09/11/06 Client: Coca-Cola North America Project: Coca-Cola North America Hot Fill Line Addition, Northampton, MA Coatractor: Hickson Producer: Construction Service Location of Concrete Placement: Addition - Col - Piers and Footings ReDorted to: Coca-Cola North America Attention: Mr. Gary Carlow CYLINDER FABRICATION - ASTM C31 DATE CAST: 09/11/06 IDENTIFICATION TIME TRUCK CLASS SLUMP EXACT LOCATION A,B,C,D 15:00 281 4500 2J" Addition - Footings 5.5 -6.5 North SLUMP TESTS - ASTM C143 AIR CONTENT TESTS - ASTM C173 or C231 Time Truck Slump Time Truck No. Air Content (�) 15:00 281 2J" 15:00 281 5.57 AMBIENT TEMPERATURE CONCRETE TEMPERATURE - ASTM C1064 Time Temperature Time Truck No. Temperature 15:00 70°F 15:00 281 72°F REINFORCING INSPECTION Rein orcing incorporated in today's concrete placement was found to be satisfactory for size, quantity, cleanliness, properly supported, adequately tied and spaced as required.in accordance with Drawing No. 4 on S 1.2. Weather: Clear Temp. : 70's No. Yds. : 20 Respectfully submitted, ALLIED TESTING LABOPkTO?IES, INC. By: Richard Bellucci President MEMBER: A.S.T.M. A.C.I. A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S. c;Z5�- /gam ALLIED TESTING LABORATORIES, INC. 1 15 St, George Road • Springfield,E iassachusetts 01 104 Phone: (4 13) 735-186 Fax: (413) 735-1838 report No. 1 of Soils Tests ;ate: 8129106 C11ent: Coca-Cola North America Project. COCA-COLA IIVORTr.' i",'ERIC.; SOT FILL LIi,'E ADD7TT0;:' PROJECT, P]OP.TFiN PTC::, .1 Subject: Soils Tests RepGrted to: Coca-Cola P:ortr A'Merica - Ltt: .'fir. Gaxy Carlo�r Hereh'1th is su:;w:itted, the results O� SGils tests conducted O: material orOpGSEd - e i r 8/25/C5 rOr use at the a.t'G%e noted prG