Loading...
31C-031 (3) ARI Ratings for Trane 4TTB6024A1 -Expanded Performance Table Page 1 of 2 LQ;' ft-1-% <R ST-+ OD MODEL ID MODEL FURNACE NOM CFM ARI REF# 4TTB6024A1 4TXCB025BC3 TUH2B060A9V3 600 5883636 Published Date:04/30/211: COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES MB ID WB TOT 75 78 80 KW 59 19.2 14.9 16.6 17.9 17.7 1.40 85 63 20.1 12.3 14.1 15.7 16.8 1.42 67 21.5 9.9 11.6 13.3 14.4 1.43 i i�l 71 1 23.3 7.6 4.3 1L0 12.1 1.44 f-�J 59 17.8 14.3 16.0 17.6 17.7 1.59 95 63 18.7 11.7 13.5 15.1 16.2 1.60 67 19.9 9.3 11.0 12.7 13.8 1.62 71 21.6 7.0 8.7 10.4 11.5 1.63 59 16.4 13.6 15.4 16.4 16.4 L77 105 63 17.2 11.1 12.8 14.5 15.6 1.79 67 18.4 8.7 10.5 12.1 13.2 1.81 71 20.0 6.4 8.2 9.8 10.9 1.83 S9 15.1 13.1 14.7 15.1 15.1 1..96 63 115 15.8 10.6 12 3 13.9 15.2 1.98 67 16.9 8.2 9.9 11.6 12.7 2.00 71 18.3 5.9 7.6 9.2 10.4 2.02 USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AIR FLOW RATE,CFM CAPACITY MULTIPT IER TOTAL POWER MULTIPLIER 525 0.98 0.99 675 L02 1.01 ARI RATING FOR COOLING CF 4 CAPACITY(A)TEST 11 SEER EER 20600 16.00 13.00 A.R.I.Standard Capacity Rating Conditions A.M.STANDARD 210/240 RATING CONDITIONS-(A)Cooling 80°F.D.B.,67°F_W.B.air entering indoor coil,95°F.D.B.air entering outdoor coil.(B)High Temperature Heating 47°F.D.B_,43°F.W.B.air entering outdoor coil,70°F.D.B.air entering indoor coil.(C)Low Temperature Heating 17°F.D.B.,15°F.W.B.air entering outdoor coil,70°F.D.B.air entering indoor coil.(D)Rated indoor airflow for heating is the same as for cooling. _ t h4s://www.comfortsite.com/Tesources(liwrature/ratings/5883636.html 5/5/2014 Load Short Form Job: wrightsoft, Date: 2ND FLOOR By: RICHIE RICHIE'S AIR CONDITIONING & HEATING 81 Industrial Lane,Agawam,Ma Project • • For: THE PECOY COMPANIES LOT 19 MOSER STREET VILLAGE HILL, NORHTAMPTON, MA Design Information____ Htg Clg Infiltration Outside db (°F) 0 87 Method Simplified Inside db(°F) 70 75 Construction quality Tight Design TD (°F) 70 12 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/lb) 29 24 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) MASTER BED/BATH 520 9611 4660 221 214 BED 2 216 3944 1638 91 75 LAUNDRY/HALL 144 3352 1901 77 87 BED 3 196 3991 2587 92 119 2ND FLOOR 1076 20899 10786 481 496 Other equip loads 0 0 Equip. @ 0.92 RSM 9923 Latent cooling 254 TOTALS I 1076 1 20899 I 10177 1 481 t 496 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-May-05 18:07:19 �+r wrlghtsaft Right-Suite®Universal201212.0.11 RSU17313 Page 3 `-+'+ ...\Documents\Wrightsoft HVAC\RICHIE'S PECOY 19 VILLAGE HILL.rup Calc=MJ8 Front Door faces: Load Short Form Job: wrightsof# Date: 1ST FLOOR By: RICHIE RICHIE'S AIR CONDITIONING & HEATING 81 Industrial Lane,Agawam,Ma Project • • For: THE PECOY COMPANIES LOT 19 MOSER STREET VILLAGE HILL, NORHTAMPTON, MA A°V5 Design Information Htg Clg Infiltration Outside db(°F) 0 87 Method Simplified Inside db(°F) 70 75 Construction quality Tight Design TD(°F) 70 12 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/lb) 29 24 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) FAM/KITCHEN/DINIG 672 12643 8111 291 373 BATH 84 1135 341 26 16 FOYER 210 4010 2765 92 127 DEN 132 3486 1950 80 90 1ST FLOOR 1098 21274 13167 490 606 Other equip loads 0 0 Equip. @ 0.92 RSM 12113 Latent cooling 130 TOTALS I 1098 I 21274 I 12243 I 490 I 606 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-May-05 18:07:19 wrlghtsoft Right-Suite®Universal201212.0.11 RSU17313 Page /� ...\Documents\Wrightsoft HVAC\RICHIE'S PECOY 19 VILLAGE HILL.rup Calc=MJ8 Front Door faces: Job: Load Short Form wrlghtsoft a U MAY 'B 2014 Bate: RicHie Entire House v RICHIE'S AIR CON D TI0VaWG &,rf AT1NGJ oections �_-60 81 Industrial Lane,Agawam,Ma Project • • For: THE PECOY COMPANIES LOT 19 MOSER STREET VILLAGE HILL, NORHTAMPTON, MA Design Information Htg Clg Infiltration Outside db (°F) 0 87 Method Simplified Inside db(°F) 70 75 Construction quality Tight Design TD(°F) 70 12 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference (gr/lb) 29 24 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80 AFUE Efficiency 0 SEER Heating input 0 MBtuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 971 cfm Actual air flow 971 cfm Air flow factor 0.023 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.98 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) 1 ST FLOOR 1098 21274 13167 490 606 2ND FLOOR 1076 20899 10786 481 496 Entire House 2174 42173 21114 971 971 Other equip loads 0 0 Equip. @ 0.92 RSM 19425 Latent cooling 384 TOTALS I 2174 I 42173 I 19810 I 971 I 971 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-May-05 18:07:19 ^►_C� wrlghtsoft° Right-Suite®Universal 2012 12.0.11 RSLI17313 Page 1 1 + Calc=MJ8 Front Door faces: ...1Documents\Wrightsoft HVAMRICHIE'S PECOY 19 VILLAGE HILL.rup RICHIE'S AIR CONDITIONING & HEATING INC. P.O. BOX 407 o 81 INDUSTRIAL LANE • AGAWAM, MA 01001 TELEPHONE (413) 789-1244 jz LA !As- collzl"'morj f0le 71iz lic-flT, LZT� �C.Z;j �+-'o :�i i4 e %-Laz;iIV'3 �C-Ts i A-2