25A-179 (16) (9 VA CORPORATE ENVIRONMENTAL ADVISORS, INC.
GARY P. ALICANDRO •Groundwater/Subsurface Investigations
President _ •Drill' Samlinp�&&Monitoring
STEVEN M. MIGRIDICHIAN €- ,.,; °evention,��Rientification& Remediation
Vice President - • fis Materials/Waste Management
emcnar and Training Development
•Industrial Regulatory Compliance
October 6, 1987 is 1%;
DEPT.OF BUMING!'
Mr. Leo J_ Kuntz, Project Director
Sverdrup Corporation
1266 Andes Boulevard
St. Louis, Missouri 63132
Re: Geotechnical Soil Investigation
Lot 12 C-2 Northampton Ind. Park
CEA Ref. File #1406-87-0919
Dear Mr. Kuntz:
Based on the soil test boring data that has been collected on
your behalf and on research of data published by the U. S.
Department of Agriculture, Soil Conservation Service, it is the
professional geotechnical opinion of Corporate Environmental
Advisors, Inc- that 3 foot 6 inches is an effective maximum
depth of footings to prevent frost action in sub-strata of the
Amostown-Windsor (Au) Complex.
The Soil Conservation Service has rated the Amostown Complex
with only moderate susceptibility to frost action, therefore it
is not appropriate to construct deeper foundation footings than
stated above for a heated slab building of this nature_
This depth also concurs with published data provided by the
U. S. Array Corps. of Engi neeria+.g (TM 5-809-1/AFM 88-3, Chap- 1 ).
Should you have any further questions please feel free to
contact us at (413) 589-0548.
Sincerely,
CORPORATE ENVIRONMENTAL ADVISORS, INC.
Alan E. Weiss Steven Migridic ian
Project Manager Vice President
Hydrogeologist Hydrogeologist
Complete Geotechnical & Environmental Services
455 CENTER STREET, LUDLOW, MASSACHUSETTS 01056 (413) 589-0548