Loading...
25A-046 (29) THE MONTESSORI SCHOOL OF NCRTHAMPTON: Outline Material Specifications, page 12 Lighting con' t : EXIT SIG NS : Install exit signs using LED (light-emitting- diode) technology. Retro fit existing signs with same . Ceiling fans ,(multi-speed) . 16720 Fire Alarm: G.C. will meet all relevant Codes requirements . G. C. will tie-in new system with existing system. Fire extinguisher and cases and pull stations as required by fire chief. END OF SPECIFICATIONS - THE MONTESSORI SCHOOL OF NORTHAMPTON: Outline Material Specifications , page 1_ 16000 Lighting: Fixture quantity and lccaticn will be based on manufactures specifications . Foot Candles (FC) levels listed are minimums . GC will ver_fy design and present to Owner for approval . CLASSROOMS 101 & 102 : Suspended fixtures equal to Litecontrol P-1D-9068T8-PARSS-CWM-TW-120E03-AC with 6 FO32/35k lamps . (Desired FC Level Rance 30 40) . LIBRARY 103 : Suspended fixtures equal to Litecontrol P-1D- 9068T8-PARSS-CWM-TW-120E03-AC with 4 FO32/35k lamps . Dimmable Track Lighting. (FC Level Range 30 40) HALLWAY 100 : Recessed fixtures in suspended ceiling grid equal to Columbia J22-232UGG-FSAI2-E38120 with two 32-Watt U- lamps, 35K lamps . (Desired FC Level Rance 20 30) . LAVS 106 & 107 : Two can fixtures with 1 or 2 - 28 Watt compact horizontal la<<:z over w. c . , Wall mounted 1 or 2 lamp wrap-around above mirror. (Desired FC Level Ranae 20 30) Install Watt stopper WS-1200/277 switchplate occupancy sensor. LAV EX-106 : One can fixture with 1 or 2 - 28 Watt compact horizontal lamp over w.c . , Wall mounted 1 or 2 lamp wrap- around above mirror. (Desired FC Level Range 20 30) . Install Wattstopper WS-1200/277 switchplate occupancy sensor. JANITORIAL CLOSET: One can fixture with 1 or 2 28-Watt compact horizontal lamps . (Desired FC Level Range 20 30) STOREROOM 105 : Two can fixture with 1 or 2 28-Watt compact horizontal lamps . (Desired FC Level Range 20 30) OFFICE 104 : Recessed fixture in suspended ceiling grid equal to Columbia J24-232G-FSAI2-EB8-120-120 with two FO32 . 35K lamps . (Desired FC Level Range 30 40) . OFFICE EX-105 : Surface mounted fixture equal to Columbia with two FO32 . 35K lamps . (Desired FC Level Range 30 40) . OFFICE EX-105 CLOSET: One can fixture with 1 or 2 28-Watt compact horizontal lamps . (Desired FC Level Range 20 30) PORCH EGRESS : Equal tc Columbia CFR626EB-132-120-RAL6 . (Desired FC Level Range 20 30) . Install damp-rated & cold- rated compact fluorescent lamps (rated to 20 below zero F) PARKING LOT: Install on building damp-rated & cold-rated flood lamp (rated to 20 below zero F) THE MONTESSORI SCHOOL OF NO=,THAMPTON: Outline Material Spec ifications , pane 10 Vent . con' t : Note : GC/=iAC contractor shall submit an air balance report . Hydronic contractor shall provide motorized combustion air intake damcers and ductwork to outside . Motors to have safety interlocks tied to boilers . 15600 A. C. CLASSROOMS 101, 102, EX-100 , and LIBRARY: Furnish and install 10 SEER condensing units, one piece blower/coil units, and related components to include dual condensate line to exterior, freon lines, and interconnection to space thermostats . The condensing units shall be installed on poured concrete mounting base outside (see plan) , provided by GC and the blower/coil units shall be installed in the attic on plywood platforms with fiberglass padding, provided by GC. Provide all ductwork, registers, and grilles to provide the following; 4 Ceiling supplies, 2 Ceiling filter return grilles All ductwcrk to be a combination of insulated sheet metal and flexible insulated spiral flex duct . The entire job is to be covered by one year parts and one year labor warranty, while the compressors shall have a five year limited warranty. System to be sized as follows ; Classrooms 4 ton, Library 2 . 5 . CLASSROOMS A,B, and EX-107: Furnish and install 10 SEER condensing units, one piece blower/coil units, and related .components to include dual condensate line to exterior, freon lines, and interconnection to space thermostats . The condensing units shall be installed on poured concrete mounting base outside, provided by GC and the blower/coil units shall be installed in the attic on plywood platforms with fiberglass padding, provided by GC. Provide all ductwork, registers, and grilles to provide the following; Classrooms; 3 high sidewall supplies, 2 high sidewall filter return grilles . Office; 1 high sidewall return, 5 floor supplies . System to be sized as follows; Classrooms 4 ton, Library 2 . 5 . OFFICE 104 : Install 9, 000 BTU wall unit (see elevation) . 16000 Electrical : G. 0 will meet all relevant Codes . Verify that existing service is adequate to carry new loads . THE MONTESSORI SCHOOL OF NC THAIMPTON: Outline Material Specifications, page c 15800 Ventilation:NEW WING a--.d CLASSROOM EX-100 SYSTEM. Ventilation system shall consist f One Lifebreath model 1200 DD- POOL, cplet�-w-it h-hydr.�n. e- co:r�:r - - s --EU� ,ed-contr-aL�-- be ma-r-nrng -up-eon�rol-ta-be-e�ectri y-pass -val-ve--t ern maT ti7 Supply duczwork in new addition will be under slab, and insulated duct in crawlspace (EX-100) . Insulated fresh air and exhaust duct to exterior. Ductwork s'--.all be installed and balanced to provide the following air quantities : Classroom #101 300 CFM Classroom #102 300 CFM Library #103 120 CFM Office #104 30 CFM Classroom #EX-100 330 CFM This system shall be designed to provide tempered fresh air during occupied hours only. LLYYT.^ jja �Z a 4 4a� C' TTT- L'IICiJ L CT'!!i'Le C Y 1 YQ��O HRV unit is to be cycled off during non-occupied hours . EXISTING CLASSROOM A & B and OFFICE AREA SYSTEM. Ventilation system shall consist of One Lifebreath model 850DCS/FD, c�etphte�7z k� r -- °`gin -rrn-=n. --��i"�TT"��'�-hV����A �--_�-�-'����'-fa}�r'-r�nrt F?�}-�i i r•7 nnn�-vnl -es.� Insulated duct in crawlspace. Insulated fresh air and exhaust duct to exterior. Ductwork shall be installed and balanced to provide the following air quantities : Classroom A 330 CFM Classroom B 330 CFM Lounge area 90 CFM Office areas 90 CFM This system shall be designed to provide tempered fresh air during occupied hours only. HRV unit is to be cycled off during non-occupied hours . THE MONTESSORI SCHOOL OF NORTHAMPTON: Outline Material Specifications, page 8 Heating con' t : Radiant manifold to be located in the custod_al room. Support manifold during concrete pour on reinforced rcd. Location to be coordinated with GC. Approval required by owner. System will have two zones : Zone 1 Classrooms & Library; Zone 2 Office, Hallway, and Restrooms . Radiant tubing to have integral oxygen barrier and minimum 20 year warranty. Cross linked poiyet'_ylene tubing is preferred. HEATING PLL�kNT: General Contractor to evaluate the capacity c= existing- boilers . G` will provide to owner heat loss calculations for existing building and new addition to support evaluation conclusions t--' i ing e ccmbustio =G�1 di� vent_ _ _ sealed r., rect , natural cas boiler is to ew be installed in existing crawl space near new additiont°r:i� ? Boiler to be protected from low return water temperature . Boiler to be vented through sidewall . Combustible clearances must be observed with venting at all times . If existing heatin !ant does hav nough capacity, then a tempering tank is to insta a (SuperStor, BoilerMate, Phase II , or equal) hea y the existing boilers as a separate zone. Water f m e tank is then piped to radiant manifold. Piping m either Lion to radiant manifolds are the same. Boiler and/or tempering tank to have minimum 20 year warranty in commercial use .1-4"- {, i(,bj<- Radiant system to be controlled by temperature limiting device (mixing valve, injection pump, 4 way valve, etc . ) to assure surface temperature of floor does not exceed 85 degrees F. Water temperature requirements of the system, as determined by tubing layout, to be included with proposal . Re-connect baseboard heating units in any area accessible from crawl space . 15400 Plumbing: G. C. will meet all relevant Codes . Re-use existing fixtures as indicated on design drawings . c-�,.,c( h)e- THE MONTESSORI SCHOOL OF NG-�ITHAMPTON: Outline Material Specifications, page 7 10800 Toilet Accessories : Equal to 2obrick. Grab bars : B550 series, 1 1/4" peened finish, 42" L. , mount on solid blocking. Mirrors : 1/4" tempered glass, 24" x 36" . TP dispenser: 2-2730 surface mounted; single roll . P. Towel dispenser: B-2621, surface mounted, stainless steel . Toilet Partitions and Urinal Screen: baked enamel, heavy duty. Terrazzo service basin with 6" drop front . Model TES-3013 (Cust . 108) . 12500 Furnishings :Venetian blinds; i" alum mini blinds (including mounting brackets) at all windows except toilet rooms and hallway. 15000 Heating System: Basement mechanical room must be enlarged to meet code . f}-55v✓�a.�:_ /11 /V trv�•_.ti� C'ic�'-�.�.ir C:.v (i1.J:Q"� �,C e_ T�.�-r«-( .t,�� -:1.�./S.J•�(( Available combustion air does not meet code . GC will install appropriate measures to rectify. RADIANT SLAB (See Alternatives) : Tubing design layout drawing (s) and specification to be provided by tubing supplier/or qualified agent . To be reviewed by owner. Minimum requirement is 12 inch on center (O/C) spacing throughout slab except 6 inch O/C for the first 2 feet of exterior perimeter of slab. Tubing to be fastened at least every 3 feet to wire mesh. Wire mesh/grid to be raised prior to concrete pour, to place tubing in middle of slab upon completion of pour. Tubing to be protected at expansion joints with one foot sleeves of pipe insulation. Coordinate locations with General Contractor (GC) . Tubing attached to radiant manifold and pressurized with air to 50 PSI during concrete pour. Heating contractor to be present during pour, with repair fittings, in case of need for emergency repair. THE MONTESSORI SCHOOL OF NCRTHAMPTON: Outline Material Specifications, page 6 09500 Suspended Ceiling: 2 ' x 2' panels, slotted spline grid: A. Suspension system equal to Dunn brand U.S .G. "fineline" , color to be white . B . Tiles : Ll�� 1) U.S .G. "Acoustone, Frost" , 2 ' x 2 ' x 3/4" , No. l � "Shadowline" edge, 70-80 NRC, 40-44 STC, foil backed. a*) - cl� , 09680 Carpet : Nylon, cz . , equal to "Academy" by Patcraft, glued down. Glue must be rated for high temperature if used with radiant floor system. All Carpet to be selected by Owner through samples by Builder. 09650 Resilient Tile : Vinyl Composite Tile, 12 x 12 inch size, 1/8 inch thick, ASTM E84 Flame Spread 75 or less, equal to Mannignton "Inspirations" . Match existing tile for color, to be approved by Owner. Sheet Vinyl : Equal to Corgoleum "Flor-Ever" , 25 mil, no-wax wearlayer. Style and color to be selected. OR Armstrong "Classic Corlon" , 50 mil vinyl, wearlayer. Style and color to be selected. Cork: Equal to Ipocork Inc . , 12" x 12" 1/8" thick, color natural . 09900 Painting: General : Colors to be selected by Owner. Painter to provide 41x 4 ' samples . EXTERIOR: Backprime all wood with primer/sealer, stain kill all knots where painted. t Cj,.f P, ; SsP,ikce1:4 ' C, L ee­z F_,,51, ;,114 ,2;i s, Exterior trim: 2 coats Moorwood vinyl acrylic semi-solid latex stain, #809 to match existing. C'v/y Cedar Siding: Match existing (2 coats clear finish) . Metal doors : 2 coats alkyd semi gloss over factory prime coat . INTERIOR: Plaster/gyp'bd. : 1 coat Kurfees Primer 225 , 2 coats Kurfees Acrylic Enamel Eggsshell, by Environmental Construction Outfitters (800) 238-5008 . a j New wood (doors, trim, and beams) : 2 coats watco penetrating oil . Cubbies : stain to match existing in color. THE MONTESSORI SCHOOL OF =C THAMPTON: Outline Material Specifications, page 5 07900 Sealants : Exterior: silicone modified acrylic; interior: latex. Assure prcper sealing of all wiring, piping, -window and door framing, and other penetrations which might serve as infiltration pathways . Use non-expanding foam at all exterior door and window rough openings . 08200 Doors : Exterior doors : Type 'A' : Brosco Steel Door, B-1058G with 3S-38 sidelite . Wood frames, adjustable aluminum thresholds . Window configuration as shown on exterior elevations . Type ' B' : Brosco Steel Door with half lite, 2-1058 . Type ' C' : 1 3/4 " thick birch veneer, flush. Solid core doors in wood frames . Custom wood frames at doors with sidelites (Classrooms 101 and 102) . Sidelites to be tempered glass . 1 Type ' D' : Moveable wall partition (Type ' C' ) equal to Holcomb & Hoke FolDoor Model 5500, hinged pairs, manually operated, top supported, 3 " panel thickness, STC 42-47; with pressure activated bottom seal activated bottom seal, lever operated, 8 ' -0" x 24' at classrooms and 8' -0" x 20' at library (See Alternates) . Provide shop drawings . t / / r. cn ha4l 1 ? �L`'r2 li^.�-�- Cnf,ZI000 q �'-jC���$i(,S�c, l v�. �.✓��r� SL[!N cull.: �/t�e''y� 08600 Windows : 616 removable, interior mullions; "Low E" glazing, full exterior screen, match existing window manufacturer. 08700 Hardware : Brass, lever handle hardware, mortised at exterior doors, match existing Schlage. Panic hardware : Russwin Exiter II Series at all exterior doors . Key all doors as per owner' s /directions . Ei� /c 09250 Gyp . Bd. : Walls & ceilings : Toilet room walls to have 1/4" plywood layer under gypsum. All ceilings and corridor walls : 1 hr. fire-rated. Spray finish at classroom ceilings (See Alternates) . THE MONTESSORI SCHOOL OF NORTHAMPTON: Outline Material Specifications, page 4 Finish Carpentry: con' t Vinyl base, 4" coved. Bathroom wainscot : plastic laminate 06400 Arch. Woodwork: Provide shop drawings for approval by owner. Cubbies : 3/4" pine to match existing. Built in casework: e-mial to "Young" solid pine and/or custom built . Porcelain pulls . Library Shelving: Custom built wood shelving, birch veneer i' plywood, edgebanding, plastic laminate tops, sizes as indicated on design drawings . Plastic laminate counters, square edged. Resinous counter top (Classroom 101) equal to Campbell Rhea "Rheafex" . Storage shelving, birch veneer plywood, edge banded. Heavy duty standards and brackets . 07200 Insulation: Frost walls and slab: 2" rigid polystyrene Vapor barriers : on warm side of all insulated walls, ceiling; full taped at all seams and penetrations, 6 mil . Walls : R-19, blown-in cellulose . Ceiling: R-30, blown-in cellulose; provide Prop-R vents each bay. Insulation on slope ceiling to be stabilized w/mesh. Acoustic Insulation between rooms : blown-in cellulose 07300 Roofing: New pitched roofing: 30 year asphalt shingles, Class A, equal to Bird Architectural 90s, color to be selected. -&Rtz_ � 15# felt . Continuous ridge vent . Ice & Water Shield: three layers (9' wide) of Grace "Bituthene" membrane ice and water shield at eaves and valleys Copper flashing. Gutter and downspout : white� ` ;� d y THE MONTESSORI SCHOOL OF NORTHAMPTON: Outline Material Specifications, page 3 06100 Rough Framina: Pressure treated where exposed to weather or Carpentry: concrete . Roof Trusses : Should be designed and fabricated according to the American Forest and Paper Association' s "National Design Specification" and the NDS "Supplement" and all relevant specifications of the Truss Plate Institute . Design and fabrication should be done by competent and experience personnel under the su:,ervision of a professional engineer. Detailed shop drawings, including a layout plan_, showing all design loads, stress levels, material specifications, plate sizes, splice locations, dimensions, deflections, and bracing requirements, should be provided, bearing the stamp of an engineer licensed in Massachusetts . Minimum design loads should be 35 pounds per square foot (psf) snow load with allowance for additional load at valleys; dead loads as indicated by finish schedules in the design drawings; partition loads at the locations shown on the design drawings . Trusses should be cambered for dead load. Transport, storage, handling and temporary bracing of trusses shall follow TPI recommendations . Truss bearing points should have hurricane anchors to exterior walls (Simpson_ Strong-Tie 111-112 " or better) Wall stud with trusses above. Roof Sheathing: 5/8" CDX with plywood clips . Exterior siding: 1/2" CDX plywood sheathing with Tyve cedar clapboards to match existing. Soffit Q eves : Equal to Wolverine Techs . (fully vented vinyl) . Color by Owner Exterior porch framing: Pressure-treated Southern pine, boxed with cedar where visible . Porch ceiling (match existing material and finish) 06200 Finish Install new windows and doors, trim, and base . Carpentry: Exterior trim: primed finger jointed clear pine at window and doors, painted (match existing color) . Cedar corner boards, fascia, etc . to match existing, natural finish. Interior trim: clear pine, square edged; match existing window sills, window & door jamb & head casing, with head casing wider and thicker than jambs . Match existing wood base profile. THE MONTESSORI SCHOOL OF NCR7 AMPTON: Outline Material Specificat_ons, page 2 02300 utilities : Site Drainage: Provide positive drainage away from foundations . Connect to sewer system on site G.r--�� n�_Gt-.ion ea���rrc_Y�e*�=t=�s-tom-ems=. Water Service: Connect to existing line on Site . Cable, Telephone and Electric Service : Connect to existing services . Natural Gas Service : Existing gas line must be upgraded. Present line is undersized for present load. Connect upgraded line in se;arate trench from Bates St . 02400 Landscape : Finish raking and seed-ing 6f disturbed areas . Protect designated existing trees to remain. Trim crown and root prune existing trees to the North of addition, feed with arborist recommended fertilizer. 03000 Concrete : Subgrade should be verified for bearing capacity to support roof/wall loads . Dig test pit with backhoe within proposed footprint before start of construction. There should be no organics, fills, of soft clays present in the existing soil . Frost walls, footings & slabs : 3000# psi min. reinforced concrete . Foundation walls 8" wide . Continuous reinforcing steel bar should be placed at the top and bottom of wall (minimum) . Exterior concrete : Should be air-entrained (60) ; 4000# psi min. Provide batching slips. Slump tests to be taken at random if Owner deems necessary. Compacted fill should be well-graded granular material, placed in 10" maximum lifts . Coordinate work with installation of all under slab utilities and radiant floor heating (should such a heating system be chosen by Owner. ) If radiant floor system is used, slab is to be reinforced with wire mesh and shall have contraction control joints x��rzy O If radiant system is not used, slab is to be reinforced with a grid of #3 rebar Q 16 " spacing both ways . 05000 Metals : Miscellaneous metals for framing, galvanized at exterior locations . THE MONTESSORI SCHOOL OF NC=-_'HAMPTON: Margo Jones, Architects Outline Material Specificat_ons with Full Circle Design Date : May 16, 1996 Revision: March 13 , 1997 General : 1 . General Bids are due to Susan Swift at The Montessori School of Northampton byc'rt��' 7, ri/ at 2 : 00 p.m. 2 . General Contractor shall be certified by the "Energy Crafted Home" program, and all framing, insulation, air exchange, etc . shall meet requirements for such Program. The building shell shall pass a "blower door test" prior to installation of interior f_4 -_fishes . CFM shall meet "ECH" standards . 3 . General Contractor shall provide shop drawings and samples of all finish materials as requested to Cwner for approval . Div. Section Description 01030 Alternates : Provide separate pricing for the following: A. Star burst cedar siding at gable end of East Porch off classrooms . B . Moveable wall partition between Library and Classroom 101 . Rough framing of opening and "break-down" wood stud and gypsum board temporary partition to be part of Base Bid. C. Glued on acoustical ceiling treatment in two classrooms in place of sprayed finish; equal to Armstrong, "Nubby" , with 1 inch wood battens at all seams . � D. Forced Hot Water Baseboard heating system vs . Radiant Slab (See concrete section for change in slab reinforcement) . E. Repair/complete existing foundation, complete vapor barrier, and remove dirt/debris (basement of EX-100) . 02100 Clearing: Remove de S4 trees . 02072 Demolition: Misc . wood framed walls; removal of pre-cast steps for re- use; careful removal of existing doors for re-use . Careful removal of existing plumbing fixtures for re-use . Capping of removed plumbing and electrical fixtures . Remove vinyl siding. Remove existing heating units in renovation area, prior to demolition of walls and bathrooms . Cap all piping in crawl space-basement. 02200 Earthwork: General excavation, back filling for foundation as indicated, and for site utility connections . Rough grading. (See Concrete Section) . BIDS DUE 4 � � �_ 19"L.. NORTHAMPTON MONTESSORI SCHOOL ADDITION Montessori School of Northampton 51 Bates Street Northampton, MA 01060 RE: GENERAL BID FOR CONSTRUCTION To whom it may concern: The Montessori School of Northampton is seeking a General Bid for construction of a 3000 square foot addition. This addition is to include two new classrooms, library, office, restrooms, and janitorial closet. The project will include the renovation of an existing office along with the removal of an existing restroom and relocation of another. It is expected that the contractor and/or the sub-contractor have experience in the following areas : Permitting Landscaping Concrete Monolithic Slab Construction Manufactured Truss Systems Design and Installation Stick Built Construction Energy Crafted Home Program Certification HVAC including HRV Systems Design and Installation Radiant Flooring Heating Systems Design and Installation Plumbing Design and Installation Electrical/Lighting/Fire Safety Systems Design and Installation Please find enclosed a Plan Set, Outline Material Specification, and a Form for General Bid for your use. There will be a pre bid meeting at the school on io& e- % at o'clock at which time questions will be answered. The owner will use AIA Documents A101, STANDARD FORM OF AGREEMENT BETWEEN OWNER AND CONTRACTOR where the basis of Payment is a STIPULATED SUM - 1987 Edition and A201, GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION - 1987 Edition, Contract forms . The school is prepared to undertake this building project this spring with completion by August 15, 1997 . This addition is to be occupied this fall session, September 1997 . The expansion committee target dollar amount for this project is $240, 000 . Questions are to be directed to Roger Cooney of Full Circle Design at (413) 624-3360 . Thank you. Susan Swift Director encl: Plan Set, Outline Material Spec. & Form for General Bid. THE MONTESSORI SCHOOL OF NORTHAMPTON: Outline Material Specifications, page 2 AD2-8 SECTION 15300 : VENTILATION Lifebreath model 1200 substitute AD2-9 SECTION 15600 : A.C. Substitute AD2-10 SECTION 16000 : LIGHTING Revise specification per Don Armour of Lighting Systems, West Hartford, CT 06107 . (860) 233-8277 . Other misc . notes : Woven valley may be better than open because of acid -rain effecting metal . Side walls 16" oc . 8 " stone under slab vs . 611 . Only need one smoke detector per room. 95% compaction for interior footing. Air tank is bad on old boiler, needs to be replaced. Why non-elec . switch on vent-- Science counter top conflict in #' s . Revise parking lot for 17 more spaces . - END OF SPECIFICATIONS - THE MONTESSORI SCHOOL OF NOF'?'??._R.MPTON: Margo Jcnes, Architects ADDENDUM NUMBER TWO with Full Circle Design Chanaes to Specifications : AD2-1 ALTERNATES : C Acoustical ceiling should be Amstrong Nubby Regular item #3200 24"x 24" x 1" . AD2-2 SECTION 03000 : CONCRETE Do not Saw-cut slab. AD2-3 SECTION 07200 : INSULATION Ceiling insulation should be R-45 . AD2-4 SECTION 08200 : DOORS Type 'D' : Moveable wall partition (Type ' C' ) should be equal to Holcomb & Hoke Foldoor Model 400 Paired Panel . Sizes should be cne 8 ' -0" x 24' -0" and one 8 ' -0" x 16 ' -011 . (317) 784-2448 . AD2-5 SECTION 09680 : CARPET Should be Nylon, 28 oz . , equal to "Academy" by Patcraft #232- 098 . AD2-6 SECTION 09650 : RESILIENT TILE Do not use Congoleum "Folor-Ever" because it is only available in 6' -0" a width. Do not use Cork because it de-laminates substitute AD2-7 SECTION 15 400 : PLUMBING Existing sink with gooseneck is Elegate 22"x24 1'x 5 1/2" by Moen. Existing toilet is 17" high Gerber EB 1 . 6 . Existing sink is Gerber K24 . Janitorial closet has 12" terrazzo Service Basin with 6" drop front model #TSB-3013 . co ro Old rim � Jiii�o lg '1 1 I , ------------------ ' ' o a i 2 , b � , oor7C� � 2 >� air ti N c / tom_-, Do n- /10 .. ^ w L-.1 I>00 x HIM pa v ,, C O to y • g n a �--1 �, z � v s Ej c 19 4 THE MONTESSORI SCHOOL OF NCRT_H.AIPTON: Margo Jones, Architects ADDENDUM NUMBER ONE with Full Circle Des i an Chances to S-cecificaticns : AD1-1 SECTION 02221 '& 02510 : ASPHALT CONCRETE PAVING A. The work of this sections consists of excavating for construction of and furnishing all labor, materials, service and incidentals necessary to install pavement work indicated in the drawing or described in the specifications . B. The contractor will excavate and compact subgrade to accommodate gravel and new bituminous pavement . Compacted gravel to :,e minimum cf G" covered by MIN. 1 1/2 " binder course . Tcp wearing course is to be MIN. of 1 1/211 . New pavement is to match grade of existing parking lot . Chancres to the Drawings : AD1-2 DRAWING L. 1, SITE PLAN A. Add parking lot . -END OF ADDENDUM ONE - AFTER ONE (1) ATTACHED DRAWING