Loading...
36-310 7MIgiE.9 t.ZLS 466 00t I1 o a . Z co '� C l —, Ln �! s ! O OD A cvp v ! ` Vii: -o - •n a O � X66 00 • gZ 3�g£ t.ZLN ,ZO 5 .�.- Rp q0 O�-(11iV•1p�0 s� tie ,.I � l5 l5 i1 V kz[_."'J f wart f1ttiiiptell _ , j D ±}J2T OF BUILDING INSPECTIONS 212 Al in S reet ' Municipal Building INSPECTOR S--T i f'T orthu npton, Mass. 01060 OP OF BL11LD,NG INSPEG,10 01060 Square Footage Amount Basement @ .10 1� lst Floor @ _40 �_ (,]sell 2nd Floor @ .20 7•a O 1/2 Floors, Attic, Garage .10 Deck, Porches .10 �5'� a7� (06 , TOTAL �49 �� Aug 14 02 10: 50a DPW 4135871576 P. 5 MUNICIPAL SEWER AVAILABILITY Northampton Streets Department 125 Locust Street Northampton, MA 01060 587-1570 133 Location: -409" Cardinal_ Way - Lot #6 Inquiry Made By: David Lepine 527-3975 Date of Inquiry: 07-31-02 Municipal Sewer Main in Front of Location: Yes No Size of Sewer Main: Material: Age: Depth of Sewer Main: Size of Service Connection: Comments: This subdivision was approved by the Northampton Planning Board on 5/23/02. It is the responsibility of the developer to provide the necessary infrastructure as shown on the approved plans. A corresponding "sewer entrance fee" shall be paid prior to making any connection to the municipal sewer system. Arrangements of such installation shall be made with the Northampton Streets Department with a minimum of 5 working days notification. All work shall conform to Northampton Streets Department specifications. -17' —ad Joseph homas, uperintendent Streets Department cc: Ned Huntley, Asst. City Engineer Anthony Patillo, Building Inspector �f. MUNICIPAL WATER AVAILABILITY Northampton Water Department P DEPT OF BUItDIFrG INSPEU,ItT6 237 Prospect St. DEPT A���zG� Northampton, MA 01060 587-1098 133 Location: 109- Oardinal Way Lot #6 Inquiry Made By: David Lepine 527-3975 Date of Inquiry: 07-31-02 Municipal Water Main in Front of Location: Yes X No Size of Water Main: 12" Material: DI Age: 2002 Approximate Street Pressure: 72 PSI Size of Service Connection: 1" copper Comments: The Water Department cannot guarantee adequate water pressure during peak demand times at elevations above 320 feet. The City of Northampton has not accepted responsibility for the maintenance of the water main and service connections as of this date of inquiry. A corresponding "water entrance fee" shall be paid prior to making any connection to the municipal water system. Arrangements of such installation shall be made with the Northampton Water Department with a minimum of 5 working days notification. All work shall conform to ampt /Water De par It specifications. < : G �) ,e ! Charles Borowski, Superintendent of Water cc: Ned Huntley, Asst. City Engineer Anthony Patillo, Building Inspector MUNICIPAL SEWER AVAILABILITY I x'09, u AUG 1_ i_ll Vii- � ftJ , Northampton Streets Department _-a - -- 125 Locust Street Northampton, MA 01060 -- 587-1570 133 Location: 109- Cardinal Way Lot #6 Inquiry Made By: David Lepine 527-3975 Date of Inquiry: 07-31-02 Municipal Sewer Main in Front of Location: Yes x No Size of Sewer Main: 2 Material: PVC Age: 2002 Depth of Sewer Main: 5' Size of Service Connection: 1-s" PVC Comments: The City of Northampton has not accepted responsibility for the maintenance of the sewer main and service connections as of this date of A corresponding "sewer entrance fee" shall be paid prior to making any connection to the municipal sewer system. Arrangements of such installation shall be made with the Northampton Streets Department with a minimum of 5 working days notification. All work shall conform to Northampton Streets Department specifications. Joseph comas, uperinteudent Streets Department cc: Ned Huntley, Asst. City Engineer Anthony Patillo, Building Inspector [ ] I Insulation R-values and glazing U-values must be clearly marked on the building plans or specifications. I Duct Insulation: [ ] I Ducts shall be insulated per Table J4.4.7.1. I Duct Construction: [ ] I All accessible joints,seams,and connections of supply and return ductwork located outside conditioned space, including stud bays or joist cavities/spaces used to transport air, shall be sealed using mastic and fibrous backing tape installed according to the manufacturer's installation instructions. Mesh tape may be omitted where gaps are less than 1/8 inch. Duct tape is not permitted. [ ] I The HVAC system must provide a means for balancing air and water systems. I Temperature Controls: [ ] I Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. I Heating and Cooling Equipment Sizing: [ ] I Rated output capacity of the heating/cooling system is not greater than 125%of the design load as specified in Sections 780CMR 1310 and J4.4. I Circulating Hot Water Systems: [ ] I Insulate circulating hot water pipes to the levels in Table 1. I Swimming Pools: [ ] ( All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. ( Heating and Cooling Piping Insulation: [ ] I HVAC piping conveying fluids above 120 OF or chilled fluids below 55 °F must be insulated to the levels in Table 2. MECcheck Inspection Checklist Massachusetts Energy Code MECcheck Software Version 3.2 Release la DATE: 07/31/02 TITLE:Lot-6 Cardnal Way Bldg. Dept. Use I Ceilings: [ ] ( 1. Ceiling l:Flat Ceiling or Scissor Truss,R-38.0 cavity+R-38.0 continuous insulation Comments: I Above-Grade Walls: [ ] ( 1. Wall l:Wood Frame, 16"o.c.,R-19.0 cavity+R-19.0 continuous insulation Comments: I Windows: [ ] ( 1. Window 1: Vinyl Frame,Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: I Doors: [ ] I 1. Door 1: Solid,U-factor: 0.350 Comments: I Floors: [ ] I 1. Floor 1: All-Wood Joist/Truss,Over Unconditioned Space, R-19.0 cavity+R-19.0 continuous insulation Comments: I Air Leakage: [ ] I Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] I When installed in the building envelope,recessed lighting fixtures shall meet one of the following requirements: 1. Type IC rated,manufactured with no penetrations between the inside of the recessed fixture and ceiling cavity and sealed or gasketed to prevent air leakage into the unconditioned space. 2. Type IC rated, in accordance with Standard ASTM E 283,with no more than 2.0 cfm (0.944 L/s)air movement from the the conditioned space to the ceiling cavity. The lighting fixture shall have been tested at 75 PA or 1.57 lbs/ft2 pressure difference and shall be labeled. I Vapor Retarder: [ ] I Required on the warm-in-winter side of all non-vented framed ceilings,walls, and floors. I Materials Identification: [ ] I Materials and equipment must be identified so that compliance can be determined. [ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. • t j N4it Number MECcheck Compliance Report Massachusetts Energy Code MECcheck Software Version 3.2 Release 1a V — ` ChOked By/Date TITLE:Lot-6 Cardnal Way Dpi GF Bti!IDiNG INSPEC?IONS h^ ?;_5 � ;C ,► A 01060 CITY:Northampton STATE:Massachusetts HDD:6404 CONSTRUCTION TYPE: 1 or 2 Family,Detached HEATING SYSTEM TYPE:Other(Non-Electric Resistance) DATE:07/31/02 DATE OF PLANS: 7-31-02 PROJECT INFORMATION: Plantation At Westfarms COMPANY INFORMATION: Dave Lepine Building Contractor COMPLIANCE:Passes Maximum UA=448 Your Home=251 44.0%Better Than Code Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Flat Ceiling or Scissor Truss 1696 38.0 38.0 24 Wall 1:Wood Frame, 16"o.c. 2682 19.0 19.0 81 Window 1: Vinyl Frame,Double Pane with Low-E 252 0.350 88 Door 1: Solid 46 0.350 16 Floor 1:All-Wood Joist/Truss,Over Unconditioned Space 1696 19.0 19.0 42 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application. The proposed building has been designed to meet the Massachusetts Energy Code requirements in MECcheck Version 3.2 Release la. The heating load for this building,and the cooling load if appropriate,has been determined using the applicable Standard Design Conditions found in the Code. The HVAC equipment selected to heat or cool the building shall be no greater than 125% the si n load as specified in Sections 780CMR 1310 and J4.4. r Builder/Designe / Date Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 11, Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(F) 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD(Building Department Use Only) U *9'99Z -i(10 'ANI -11 oz = q°m I i►6'S9Z =(Z l'l l 80) NI 'ANI i Jam m ) ££'OLZ ='A313 W18 21,£ 99+91 'V1S L HVNIO TZVOS , DlHdVHD Ss q ss Qo9 G Z S _...�. I , ,tit a 3.9£.9�ZLN 00+9 t 00+L t >nVM301S 'ON00 'lib 'dONd XO'Z=90 d38 O Z t d0 --1L l 6 i R I 1311 I i I i 1 I i 'r .y 1 . :> CITY OF NORTHAMPTON, MASSACHUSETTS DEPARTMENT OF PUBLIC WORKS 125 Locust Street Northampton, MA 01060 T� 413-587-1570 Samuel B. Brindis, P.E. Fax 413-587-1576 Director, City Engineer Guilford B. Mooring, P.E. Assistant Director of Public Works BOARD OF PUBLIC WORKS DRIVEWAY PERMIT GENERAL INSTRUCTIONS AND REGULATIONS 1. A "Driveway Permit" is required in all cases where a new curb cut or an alteration to an existing curb cut is proposed on a City public way. 2. Driveway permits issued by the Board of Public Works (BPW) shall be attached to and become part of the 'Building Permit" issued by the Building Inspector. 3. Prior to the issuance of a 'Building Permit" the owner of any lot to be serviced by a new driveway shall apply to the BPW for a "Driveway Permit" by completing the pertinent portions of the permit (see attached). Once the location of the driveway is approved by the BPW, a building permit may be issued. 4. The Building Inspector shall not issue an "Occupancy Permit" unless the driveway to the lot has been approved by the BPW. 5. By the issuance of a driveway permit for the stated location, neither the City of Northampton nor the Department of Public Works imply that no drainage problems will result with the driveway when constructed. Properties situated or driveways installed in low lying areas in the path of the natural drainage will be subject to water problems. These problems may include water sheeting across roadways adjacent to the driveway. The City and the DPW assume no responsibility for any such drainage problems. The owner of the property is responsible for constructing and maintaining the driveway with adequate provision for natural water runoff situations. `C6 muel B Brindis, P.E. Director of Public Works C:\MyFi1es\L3m\Driwway Permit General Instructions Permit No. D03-03 Conditions: Driveway Permit In lieu of plan approved by City Engineer I agree to the following added conditions: 1. I will contact the Department of Public Works and have an inspector check and approve the graded gravel base prior to paving to insure compliance with slope and location; 2. I further agree that if in the inspections any of the permit conditions are not met that I will at no expense to the City remove and replace the driveway as directed by the City Engineer. -,e'By: David Lepine 1t1�Jlr 262 East Stre , Ea�sythampton, MA 01027 Note: The Public Works Department recommends that you provide a plan showing the proposed driveway with grades and location in the future to avoid possible expense which you will incur by not getting approval of actual plans in advance. 4 fly i Permit No. D03-03 k. CITY F NORTHAMPTON, MA RIVEWAY PERMIT Date: 07-31-02 FEE: $25.00 CHECK N: 5208 THE BOARD OF PUBLIC WORKS The undersigned respectfully petitions your honorable body for: 153 Permission to install a driveway at ice' Cardinal Way -Lot 6 Fifteen (15) foot maximum width at the street line. Gutter drainage not to be disturbed. All drainage shall be directed off the driveway surface to adjacent land and not on the existing roadway. Driveway surface to be paved if the grade of the proposed driveway exceeds 3% or more. .,<-By: David Lepin 527-3975 262 East S reet, Easthampton, MA 01027 Telephone #: 577-qq Proposed Location Inspected By: ��- - - O.1-., Gravel Base Grade Inspected By: Final Approval THE BOARD OF PUBLIC WORKS voted that petition be granted. George Andrikidis Director of Public Works (SUBJECT TO ATTACHED CONDITION 1 & 2) cc: Building Inspector 4-TtiAMPyp a e, Crxt� of 'Wartijaniptoll = � B �:saxclltrsrtta m DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street ' Municipal Building Northampton, Mass. 01060 , WORKER'S COMPENSAUON INSURANCE AFIATDAVIT I, i YJ wl_ kyI --I e- (licensee/permittec) with a principal place of business/residence at: o?l 3 E45'_ ST iS'Tt�R{ -�,DTO� I-M A'oa7 (phone#) V13- Sa 7-3 9 7S_' (st=ucity/statehip) do hereby certify, under the pains and penalties of per3ury, that: O I am an employer providing the following worker's compensation coverage for my employees working on this job: 4Y C� T ' ' 8 a � v � (Insurance Company) (Polio Number) (Expiration Daze) Cm a sole proprietor, general contractor or homeowner (circle one) and have hired the contractors listed Fero who have the following worker's compensation policies: 101el Z CoQS,- vc•nov /M dM19 Z2S ,r oc (Name of Contractor) (Insurance Company/Policy Number) (Expiration Date) W-4 z 6av a 5770/-4aL', �r w �c c✓C� - *Wtcf} /40,4C 4s6o✓1iuxe ro gyp-5-e>3 (Name of Contractor) gnsu�G �3 t S Ley Number) (Expiration Date) u?ffi ke ,'/ec_ri, C �14�.. /ws S�0 7-efi� e�3 (Name of Contractor) (Insurance CommDauy/Policy Number) (Expiration Date) W C7 qe4 at to <�AaY Kosre4 / t 2,a2►rt� S ,�-RILtCeS y-ao-0 3 (Name of Contractor) Gns-urana°Company/Policy Number) (Expiration Date) (attach additiorW thcct if,,6C u ry to inc}udc iaforcni.•ioo pcstaiuing to all roa.7aciors) �G 5(cl� fp I (oaf (y) I am a sole proprietor and have no one working for me. ( ) I am a home owner performing all the work myself. NOTE:pteaae be aware that whim homeowners who cmplay pcma=to u ion cs repair worst on a dwelling of not more tt>_:n thrce units is which the homoostincr resida or on the grourrd3 appurtcnaut thcr t arc oo<gaxc n y ox=dcrcd to be employes under the wogs aapeusaiico Act application by a homcowna for a U--n-cc pcfmit may evidence the Itgal stabs of an omployoc under tho Woriceea Compooaation Aci I undcraAnd that a copy of this rtxtcmcnl may bo fbrwiudcd to tho Dtportnx-os of Industrial Atcid—&Offioo of Iusav*ace for the coverage va ifiadion and that adore to accitre coverttgo undcr soctioa 25A of Mot,152 can lead to the imposition of criminal pcnali:cs oomixdi of a fime of trp to S1,500.00 andlor impriso�of up to one year and civil prnaltics is the form of a Stop Work Ord--and a firm of S 100.00 a day against M For dcga�trio only Ge Permit Number Map' Lot Signature of Lt ermittce Late SECTION'8'-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder : ­ >AVIA0 I—i . k4wlkp� License Number Addr � Expiration Date 13 5'a -3 y 757 Signature Telephone Regi's erect ATM11�impri v`e—i t"' traction �, `� � s„�. . . � 9, 00, .`, � PP �a Not Applicable ❑ Company Name Registration Number Address Expiration Date Telephone SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G L. c. 152, § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... No...... ❑ w � , r,� q, 1:1: -eH.ome OnerExemp�><an The current exemption for"homeowners”was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license, provided that the owner acts as supervisor. CMR 780 Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person(s)who own a parcel of land on which he/she resides or intends to reside, on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures. A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner" shall submit to the Building Official, on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the buildinp-permit. As acting Construction Supervisor your presence on the job site will be required from time to time, during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152 (Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner" certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature SECTION 5 DESCRIPTION'OF PROPOSED WORK'(check all applicable) New House 16 Addition ❑ Replacement Windows Alterations) ❑ Roofing ❑ Or Doors ❑ Accessory Bldg. ❑ Demolition❑ New igns [ Jj., Decks [ ] Siding[ ] Other [ ] eVT Brief Description of Proposed Work: -n ,sf Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative❑ Renovating unfinished basement Yes No Plans Attached Roll o - Sheet❑ 6a.,JUWw do se and or$atldition to`ezisting ho'using,ecomplete he="fo11"owr'ng a. Use of building : One Family X0 Two Family Other b. Number of rooms in each family unit: $ Number of Bathrooms a� c. Is there a garage attached? yes d. Proposed Square footage of new construction. aq-767 Dimensions 5a X S 3 e. Number of stories? v� f. Method of heating? T °S ro✓tIC*4 hlCr Alf? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Mascheck Energy Compliance form attached? h. Type of construction CVL) .5j"e- i. Is construction within 100 ft. of wetlands? Yes _ ( - No. Is construction within 100 yr. floodplain _—_Yes__X—No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? X Yes No . I. Septic Tank City Sewer well City water Supply _ SECTION 7a -OWNER AUTHORIZATION -TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT as Owner of the subject property hereby authorize _ to act on my behalf, in all matters relative to work authorized by this building permit application. Signature of Owner Date as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Print Name Signature of Own gent . Date Section 4. ALL INFORMATION MUST BE COMPLETED, or PERMIT CAN BE DENIED DUE TO LACK OF INFORMATION Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size 8•/7�J �%. �� SAS C i Frontage /00- Setbacks Front ilo ; Side L: )1111F R: /0 L: g� R: Rear 'e8 Building Height 31d(l,��A v feA Bldg. Square Footage / ' % s Open Space Footage % J b� (Lot area minus bldg&paved 1 parking) #of Parking Spaces Fill: �D volume&Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO DON'T KNOW YES _ IF YES, date issued: 44y a3 C�)©Oa IF YES: Was the permit recorded at the Registry of Deeds? NO DON'T KNOW YES _ IF YES: enter Book &&173_ Page /(off and/or Document # B. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW _. YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained Date Issued: C. Do any signs exist on the property? YES NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property?YES No IF YES, describe size, type and location: r i. it orthampton t !� �. B u i Department r, ain Street vvrrer e t ad: o m 100 Nor or on, MA 01060 � r p t g�ig,I�W1(3x'587.12 0 Fax 413-587-1272 PIO !Z>1 e i ---�a APPLICATION TO CONSTRUCT, ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 - SITE INFORMATION 1.1 Property Address: This section to be comp)"eted byoffice t #' /✓ Lot. ff � .Unit �'ot to CAIWA.)4h w.AV Map Zone OuerlayDistr►ct Elm St.District CB District SECTION'2- PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: 11�)A�tlp wl . L.eP� a(Oa 57- S"T .75rHA•NP7&J AAA Name(Pri t) ��rrent Mailing Address: (Ojf=ciAe) Sod 7-3 f7S S-6 3-VY-513 Telephone Signature 2_2 Authorized Agent: Narne(Print) Current Mailing Address: Signature Telephone SECTION'3 - ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars) to be Official Use Only completed by ermit applicant 1. Building r Pjc� (a) Building Permit Fee c�0© 2. Electrical O a (b) Estimated Total Cost of Construction from 6 3. Plumbing �O Q0C)- Building Permit Fee 4. Mechanical (HVAC) /o? odes . oZ7 5. Fire Protection 6. Total =(1 + 2 + 3 + 4 + 5) vz> Check Number Aft 2 This Section For Official Use Only Aft _ Building Permit Number: JA Date Issued: Signature: Building Commissioner/Inspector of Buildings Date File#BP-2003-0123 APPLICANT/CONTACT PERSON DAVID LEPINE ADDRESS/PHONE 262 EAST STREET (413) 527-3975 PROPERTY LOCATION LOT#6- 133 CARDINAL WAY MAP 36 PARCEL 310 001 ZONE SR THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid . G Typeof Construction: CONSTRUCT 2 STORY SFH W/ATT GARAGE/DECK New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 044188 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFO ATION PRESENTED: pproved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Co ssion Signature of Building Official Date Note:Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of Planning&Development for more information. BP-2003.0123 GIs#:M1 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON Lot: -001 Permit: Building Category: BUILDING PERMIT Permit# BP-2003-0123 Project# JS-2003-0243 Est. Cost: $182000.00 Fee: $960.80 PERMISSION IS HEREBY GRANTED TO: Const. Class: 5B Contractor: License: Use Group R4 DAVID LEPINE 044188 Lot Size(sq. ft.): Owner: DAVID LEPINE Zoning: SR Applicant: DAVID LEPINE AT. LOT #6 - 133 CARDINAL WAY Applicant Address: Phone: Insurance: 262 EAST STREET (413) 527-3975 Workers Compensation EASTHAMPTON MAO 1027 ISSUED ON:8123102 0:00:00 TO PERFORM THE FOLLOWING WORK.-CONSTRUCT 2 STORY SFH W/ATT GARAGE/DECK POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: Fee Type: Receipt No: Date Paid: Check No: Amount: Building 8/23/02 0:00:00 5210 $960.80 212 Main Street,Phone(413) 587-1240,Fax: (413)587-1272 Building Commissioner-Anthony Patillo oiiriud Xuogluy-iauozssmauoj guipimg ZLZI-L85(Elf):x"sd`OtbZt-L89(£Ib)auogd POPS uIrW ZIZ 08'096$ OIZS gu!ptmg :Junouiv :ON xaagj :piUd aIeQ W:ON taaag :a 1,aad :aan;uu Is oue noaO jo ale5ijilaa0 'S aNv sarm?I S,LI do Axv AIOLLVrIOIA AIOdII AIO,LdLi'HJUONI 90 Al JKLA'a(I OAaH 39 r�VIAI,,LIIARIad SIH.L_ A / 9,0—/ `�� :teut� ������ :axouis :iuut3 CIO '� +�� �®moneinsui :Iip :g2no-d :Xaumtga1aauida.gj ;uampu )Q FI—Ij mg :atuu ig g2uo-a Ea r :Icu But :isu�Ben+anuQ �0, _ b x Dmot;ppunog #asnoH w ItZIMq2nou p�g2nog :s2upooA %Ia;aw :aatAlas :punox2japua, .ioaaadsui 3aiplmg •M•d•Q 2uijtAA;o jo;aadsul Dutgmnid;o ioaaadsuj .Ld3M.LS 21H.L WOUA TIHISIA SI,LI OS UHV3 SIH.L ISOd X1034/30V6V!D ii`d/M H3S AdOiS Z i0ndiSN00-*XY01ii JATLII0770J 9H.I"Odr.Ygd 01 00:00:0 MACZ/8-A1O a9I)SSI LZOTOVINNOidAdHiSd3 u01jusua uz0O sxaxio,AA SLK-LZS RIO .La3uis .LSda Z9Z :aauvinsul :auogd :ssa5ppV;uv3tp V AVM �VNIGdVO SST - 9# iM -*.Iii 3 N I d3I Cl IAVG :;uvat1 V xs : utuoZ aXlclg7 QIA` G :JauMO s Uff io"I 88IJbV0 3NId3l GIAVG yx : n-61D asn :asuaaz7 u0poijuoa gs:ssE13 Isu05 :01 a9IMVWi9 d S"JH SI AtOISSI"gd 08-096$ :a-3-1 00'000Z8i 505Isg St7Z0"SOOTS(' #;00.01,1 £ZTO-SOOZ-d8 #Ituuad ZI-"- —Ad ONIC[rILfiS : o aIEo uippn8 :I!Lulad 100- :101 i 1�IO,LdIATVH,L2iOl�i 30 �i.Li w. N ' -) .L li�i VSSVIV 4O H 'IV3A,',-N0W03 S.L,Z3SIlH # SZT0 £OOZ d8 AWAIlym oM 's#ir~r