31B-296 (6) a n fAi,n C►Q � �7`lf / Project Jab: Pro Summary J Summary Date: Feb 14,2014 - - wrightsoft° Entire House BY: Project Inf• • For: 3 TYLER COURT, NORTHAMPTON, MA Notes: Weather: Springfield Westover AFB, MA, US Winter Design Conditions Summer Design Conditions Outside db 0 OF Outside db 87 OF Inside db 70 OF Inside db 75 OF Design TD 70 OF Design TD 12 OF Daily range M Relative humidity 50 % Moisture difference 24 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 28867 Btuh Structure 20791 Btuh Ducts 2887 Btuh Ducts 2079 Btuh Central vent(0 cfm) 0 Btuh -Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 31754 Btuh Use manufacturer's data n Rate/swing multiplier 0.92 Infiltration Equipment sensible load 21041 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2555 Btuh Ducts 0 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 856 856 Equipment latent load 2555 Btuh Volume(ft') 8732 8732 Air changes/hour 1.20 0.50 Equipment total load 23595 Btuh Equiv. AVF (cfm) 175 73 Req. total capacity at 0.70 SHR 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80 AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual air flow 1223 cfm Actual air flow 1223 cfm Air flow factor 0.039 cfm/Btuh Air flow factor 0.053 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.90 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. 2014-Feb-14 15:53:2 t wrilghtsOft` Right-Suite®Universal 2013 13.0.09 RSU07086 Page ...n\My Documents\3 TYLER COURT,NORTHAMPTON,MA.rup Calc=MJ7 Front Door faces: N Load Short Form Job: Date: Feb 14,2014 . . wrightsaft, Entire House By: Project • • For: 3 TYLER COURT, NORTHAMPTON, MA Design Information Htg Clg Infiltration Outside db (°F) 0 87 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TD(°F) 70 12 Fireplaces 0 Daily range - M Inside humidity (%) 50 50 Moisture difference (gr/Ib) 50 24 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80 AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual air flow 1223 cfm Actual air flow 1223 cfm Air flow factor 0.039 cfm/Stuh Air flow factor 0.053 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.90 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) READING ROOM 168 18415 12087 709 646 COMMONROOM 132 2634 1988 101 106 COMMONS BATH 72 1371 1008 53 54 BEDROOM 203/CL. 247 4764 3587 183 192 BEDROOM 204/CL. 238 4571 4200 176 225 Entire House d 856 31754 22870 1223 1223 Other equip loads 0 0 Equip. @ 0.92 RSM 21041 Latent cooling 2555 TOTALS 856 31754 23595 1223 1223 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. u� 2014-Feb-14 15.50:01 !�w-� + ^"g'�ft' Right-Suket UnWarsal201313.0.0903 7, Page 1 -fJG. k..AWy OocumentsQ TYLER COURTNORThfAMPTON,MA.rup Calc='MJ7 Front Door faces: N INSURANCE COVERAGE: I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L.Ch.112 Ye&fZ No❑ If you have checked Yes,indicate the type of coverage by checking the appropriate box below: A liability insurance policy ❑ Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: I am aware that the licensee claps not hay p the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application waimm this requirement. Check One Only Owner ❑ Agent ❑ Signature of Owner or Owner's Agent By checking this box13,1 hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation:YES NO Prngrpec InenpPtlAne Date comme tc Final Inepee inn Date (nmmPntc Type of License: By -Master Title ❑Master-Restricted City/Town ❑Journeyperson ' Signature of Licensee Permit# ❑Journeyperson-Restricted 2 License Number: 7 �j (- y Fee$ Check at macc_n�nvhipl Inspector Signature of Permit Approval Commonwealth of Massachusetts Of Northam .� City O ton p MAR — 4 'u i.r� 'i Sheet Metal Permit Permit ec' Estimated7o$ ' Permit Fee: $ Plans Submitted: YES NO Plans Reviewed: YES NO Business License# Applicant License# 3 7 a� Business Information: Property Owner/Job Location Information: Name: L' od ykxk-S ��vM bltis fl4ame: C rx- le Street: !� C9 (c 5e `�1( �f 1✓t�' Street: 3 ! y 1-e f C T City/Town: go v rkc;o gbT City/Town: IVo t'TkaM /J 10 h Telephone: (A 1 —rj a j-d-Z 7's- Telephone: Photo I.D. required/Copy of Photo I.D. attached: YES NO Staff Initial J-1 /M- nrestricted license J-2 /M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less Residential: 1-2 family eL Multi-family Condo/Townhouses Other Commercial: Office Retail Industrial Educational Institutional Other Square Footage: under 10,000 sq. ft. _,/ over 10,000 sq. ft. Number of Stories: Sheet metal work to be completed: New Work: r)J Renovation: HVAC t./,- Metal Watershed Roofing Kitchen Exhaust System Metal Chimney/Vents Air Balancing Provide detailed description of work to be done: A , (- 1 �15 oh!,�, Ott, a i O g l'q )k 'J-hd �4 41, 4 le 1,1 co �_.cfi I-(oho-ce A- VIC Fees with Building Permit: $25.00 Residential, $50.00 Commercial. Fees for jobs without a Building Permit$6.00 per$1000 Minimum fees for jobs without Building Permit$50.00 Residential,$100.00 Commercial File#SM-2014-0047 APPLICANT/CONTACT PERSON WALUNAS PLUMBING&HEATING INC ADDRESS/PHONE 218C COLLEGE HIGWAY (413)529-2675 —51+600 PROPERTY LOCATION 3 TYLER CT MAP 3 1 B PARCEL 296 001 ZONE URC000)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid Typeof Construction: ADD AIR CONDITIONING&AIR HANDLER FOR ADDITION New Construction Non Structural interior renovations Addition to Existing Accesso Structure Building Plans Included: Owner/Statement or License 3724 M 3 sets of Plans/Plot Plan THE FOLL ING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFO TION PRESENTED: pproved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER: § Intermediate Project : Site Plan AND/OR Special Permit with Site Plan Major Project: Site Plan AND/OR Special Permit with Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee om Elm Street Commission Permit DPW Storm Water Management Date 4ature Oingfficial Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact the Office of Planning&Development for more information. 3 TYLER CT SM-2014-0047 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON GIS#: 6129 Map: 131B " Bock: 296 SHEETMETAL PERMIT - . , Lot: 001 . Permit: (SHEETMETAL Category: jSHEETMETAL Permit# SM-2o 14-0047 _. PERMISSION IS HEREB Y GRANTED TO: _- Project# 2-2014-000833 Contractor: License: Expires: S . E t Cost: $6,200.00 Fee Charged: WALUNAS PLUMBING&HEATINSheetmetal-3724 M 12/28/2015 - - --- ,Balance Due:l$.00 Owner: CHRISLER JENNIFER&CHERYL JACQUES #of Fixtures:11 Applicant: WALUNAS PLUMBING&HEATING INC DigSafe# AT. 3 TYLER CT I Use Group I �ConstClass ISSUED ON. 04-Mar-2014 AMENDED ON: EXPIRES ON. TO PERFORM THE FOLL O WING WORK. ADD AIR CONDITIONING&AIR HANDLER FOR ADDITION THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fee Type: Receipt No: Date Paid: Check No: Amount: Sheetmetal REC-2014-003995 04-Mar-14 5942 $25.00 212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:Ihasbrouck @ northamptonma.gov GeoTMS®2014 Des Lauriers Municipal Solutions,Inc.