23B-046 (167) SECTION VI--REACTIVITY DATA
STABILITY: UNSTABLE ( ) STABLE ( X ) 8 Cn
Pc,`
CONDITIONS TO AVOID: N/A i (
INCOMPATABILITY (MATERIALS TO AVOID): See Supplemental Sheet
HAZARDOUS DECOMPOSITION PRODUCTS: Lower fluorides of sulfur
HAZARDOUS POLYMERIZATION: MAY OCCUR ( ) WON'T OCCUR ( X )
CONDITIONS TO AVOID: N/A
SECTION VII--SPILL OR LEAK PROCEDURES
STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED:
Evacuate all personnel upwind and away from affected area. Stop leak if possible.
If leaking container(s) is (are) in an enclosed area, ventilate to acceptable
respirable oxygen level before entering.
WASTE DISPOSAL METHOD:
Locate leaking containers in a remote downwind area outside and allow to vent to
atmosphere. Follow all federal, state and local regulations.
SECTION VIII--SPECIAL PROTECTION INFORMATION
RESPIRATORY PROTECTION: In event of major leak, self-contained breathing
apparatus may a required.
VENTILATION: LOCAL EXHAUST ( X ) To prevent accumulation so as to ex-
MECHANICAL (GENERAL) ( X ) clude an adequate oxygen supply
PROTECTIVE GLOVES: Any material EYE PROTECTION: Safety goggles
or glasses
OTHER PROTECTIVE EQUIPMENT: Safety shoes
SECTION IX--SPECIAL PRECAUTIONS
PRECAUTIONS TO BE TAKEN IN HANDLING AND STORING:
Protect cylinders against physical damage. Store in cool, dry, well-ventilated
area away from sources of heat or direct sunlight. Do not allow areas where
cylinders are stored to exceed 125°F. Use a check valve or trap in the cylinder
discharge line to prevent hazardous backflow. Cylinders. should be stored upright
and firmly secured to prevent falling or being knocked over.
OTHER PRECAUTIONS:
Use only DOT or ASME coded containers. Use a pressure reducing regulator when con-
necting cylinder to lower pressure piping or systems. Close valve after each use
and when empty. For more information refer to CGA Pamphlet P-I "Safe Handling of
Compressed Gases in Containers." Cylinders may not be refilled except by or with
the consent of Liquid Carbonic.
Reporting under SARA, Title III, Section 313 not required.
NFPA 704 N0. for gaseous sulfur hexafluoride = 1 0 0
No guaranty is made as to the accuracy of any data or statement contained herein.While this material is furnished in good faith,NO WARRANTY
EXPRESS OR IMPLIED,OF MERCHANTABILITY,FITNESS OR OTHERWISE IS MADE.This material is offered only for your consideration,investigation
and verification and Liquid Carbonic shall not in any event be liable for special,incidental or consequential damages in connection N6 its Tigisation.
PAGE 2 U LLJ
l�
-Pb_
Sheet - - MATEMAL SAFETY DATA SHEET
97367 la•851 MSDS NUMBER , 60,030-9 PAGE I
24 HOUR EMERGENCY:ASSISTANCE GENERAL MSDS ASSISTANCE 11
SHELL' 713-473-9461 CHEMTREC: 800-424-9300 SHELL: 713-241-4819 BE SAFE
READ OUR PRODUCT
ACUTE HEAITM FIRE REACTIVITY SAFETY INFORMATION
LEAST - 0 SLIGHT - I MODERATE - 2 ...AND
C t t O HAZARD RATING , PASS IT ON
NIGH • 3 EXTREME - L
1M(WV[T I law
uouurs rs n1 q
*For acute and chronic health effects refer to the discussion in Section 111
SECTION i ,:: NAME
PRODUCT SHELL DIALA(R) OIL AX
CHE%AICAL r MIXTURE (SEE SECTION II-A)
NAME
CHEMICAL
FAMILY PETROLEUM HYDROCARBON; INDUSTRIAL DIELECTRIC OIL
5H-'CE ' 68702 69702 68745 69704
COD
----------------------------------------------------------------------------------------------------
SECTION II-A PRODUCT/INGRED,IENT
----------------------------------------------------------------------------------------------------
NO. COMPOSITION CAS NUMBER PERCENT
----------------------------------------------------------------------------------------------------
SHELL DIALA OIL AX MIXTURE 1CC
SOLVENT REFINED HYDROTREATED MIDDLE DISTILLATE 64742-46-7 30-40
2 SEVERELY HYDROTREATED LIGHT NAPHTHENIC DISTILLATE 64742-5--6 60-70
3 BUTYLATED HYDROXY TOLUENE 138-37-C <0.2
NOTE: DIALA OIL CONTAINS NO DETECTABLE LEVELS (<1 PPM) OF PCB AS MEASURED EY ASTM D4059.
----------------------------------------------------------------------------------------------------
SECTION II-B ACUTE TOXICITY DATi,
----------------------------------------------------------------------------------------------------
NO. ACUTE ORAL LD50 ACUTE DERMAL LDSO ACUTE INHALATION LCSO
----------------------------------------------------------------------------------------------------
2 >5 G/KG. RAT >2 G/KG. RABBIT NOT 4vZI LABL-E
BASED UPON DATA AVAILAELE TO SHELL, COMPONENT 3 IN THIS PRODUCT IS NOT HAZARDOUS UNDER OSHA HAZARD
COMMUNICTION 1'29 CFR 1910. 1200).
----------------------------------------------------------------------------------------------------
SECTION III HEALTH INFORMATION
----------------------------------------------------------------------------------------------------
THE HEALTH EFFECTS NOTED BELOW ARE CONSISTENT WITH REOUIREMENTS UNDER THE OSHA HAZARD COMMUNICATION
STANDARD (29 CFR 1910.1200) .
EYE CONTACT
BASED ON ESSENTIALLY SIMILAR PRODUCT TESTING PRODUCT IS PRESUMED TO BE NONIRRITATING TO THE EYES.
SKIN CONTACT
EASED ON ESSENTIALLY SIMILAR PRODUCT TESTING PRODUCT IS PRESUMED TO BE SLIGHTLY IRRITATING TO THE
SKIN. PROLONGED AND REPEATED CONTACT MAY, RESULT IN VARIOUS SKIN DISORDERS SUCH AS DERMATITIS.
FOLLICULITIS OR OIL ACNE. RELEASE DURING HIGH PRESSURE USAGE MAY RESULT IN INJECTION OF OIL INTO
THE SKIN CAUSING LOCAL NECROSIS.
INHALATION
INHALATION OF VAPORS (GENERATED AT HIGH TEMPERATURES ONLY) OR OIL MIST MAY CAUSE A MILD IRRITATION
OF THE MUCOUS MEMBRANES OF THE UPPER RESPIRATORY TRACT.
- ADD the following to the existing Note:
"From junction box , provide empty 3/4 "
conduit run above suspended ceiling to
existing cut-down board in Switch Room .
Intercom wire to be accomplished by Hospital
personnel .
- REPLACE and ADD the following Note in General
Electrical Notes , (G. Nurse Call) :
"Provide Nurse Call staff station, four (4)
emergency stations, and dome lights to match
existing Ducane Nurse Call system. The
connection of home run is inside Coat Alcove
B101 . All conduits shall be 3/4" minimum.
The local supplier of Ducane is Audio and
Security Engineering , West Springfield ,
Massachusetts . The emergency station
requires 1-gang, 3-1/2" deep masonry box.
The dome light requires a 2-gang , 3-1/2 "
deep masonry box. The size of the junction
box i s 6" x 6" x 611. "
R. Sheet FP-1/1 - Fire Protection Plan:
REMOVE and RELOCATE the existing 6" main to the
following location:
"The General Contractor shall tie-in the new
sprinkler system to the existing 6" main located
above the suspended ceiling in the existing
Vestibule EB-100 adjacent to Reception B103 and
Coat Alcove B101."
GENERAL INFORMATION FOR ALL GENERAL CONTRACTORS
A. O . B . Hill , 175 West Central Street , Natick ,
Massachusetts , is the Hospital-selected Rigger for
moving all Varian Linac equipment/accessories for
this project. Contact Brian Hill , (617) 235-1880,
(FAX No. (508) 651-1257) to coordinate work.
END OF ADDENDUM
10 of 10
c) "The General Contractor shall provide and
apply 2 " rigid polystyrene perimeter
insulation on all vertical exterior wall
surfaces . "
0. Sheet AI-1/1 - Interior Finish Plan - 1/8" :
- REPLACE the Note in "Key to Materials in
Finish Schedule" with the following:
"P2 - Sprayed-On Vinyl Paint System by
Polomyx"
- ADD door symbol to the Interior Finish
Plan in the following area :
" Single door opening in Gown B126 and
Outpatient Waiting B119 wall adjacent to the
new Corridor B141. "
P. Sheet E1/4 - Electrical Lighting and Power
Diagrams :
ADD exact location of existing Nurse Call master
unit :
The existing Nurse Call master unit is located
inside the Coat Alcove B101.
Q. Sheet E2/4 - Electrical Power:
- ADD paging speaker (s) the following areas
(the symbol shall be � ) and in General
Electrical Note "L" :
a) The overhead paging speaker symbols shall be
centered in ceiling of Corridor B141 and
B143 . One ( 1 ) speaker per corridor is
required.
b) L. Paging Speaker
1) Connect new paging speakers to existing
speaker wiring in Corridor B127.
2) Contractor to install Hospital-supplied
wire and speakers . General Contractor
to provide 1/2" conduit with flex to
speakers .
9 of 10
N. Sheet All/11 - Waterproofing and Dampproofing
Details:
- DO NOT USE the following Waterproofing. Detail:
"Detail ll/All - High to Low Roof"
- DO NOT USE the following waterproofing product
data and literature:
"QSC-711 - Pre-Pave Sheet Membrane
Waterproofing System"
- REPLACE the Note in Details 1, 2, 3
and 8/All with the following:
a) "The General Contractor shall apply two (2)
layers of QSC-701 Waterproofing Membrane
with one ( 1) layer of Q-Board (Protection
Board) above the new Treatment Room B140
area ."
b) "The General Contractor shall apply one (1)
layer of drainage composite on vertical walls
immediately after installing one (1) layer of
QSC-701 Waterproofing Membrane. "
c) "The General Contractor shall overlap two (2)
layers of QSC-701 Membrane with Q-Board over
one ( 1 ) layer of QSC-701 Membrane with
drainage composite wherever it occurs ."
d) "The General Contractor shall provide and
install 2" rigid polystyrene perimeter
insulation on all vertical exterior wall
surfaces . "
- REPLACE the Note in Detail 4, 5, 6
and 7/All with the following:
a) "The General Contractor shall apply one (1)
layer of QSC-701 Waterproofing Membrane with
one ( 1) layer of Q-Board (Protection Board)
above the new Linac supporting area . "
b) "The General Contractor shall overlap one (1)
layer of QSC-701 Membrane with Q-Board over
one ( 1 ) layer of QSC-701 Membrane with
drainage composite wherever it occurs ."
8 of 10
L . Sheet A9/11 - Wall Types and Details :
- ADD the following Note to 6 & 7/A9:
"The General Contractor shall provide and
install 1/4" thick x 15" x 24" mild steel
plate required for laser mounting . The
General Contractor shall coordinate work with
the Varian Installation Coordinator . It is
important that the General Contractor first
verify with the laser unit manufacturer
(Centralite Patient Positioning Laser Light
by Diaco) , 3191 South 3300 East, Salt Lake
City, Utah 04109 ; Telephone: (801) 467-0050 ;
FAX No . : ( 801) 487-3258 , prior to ordering
the steel mounting plate ."
- ADD the following Note to Detail 13/A9 :
"The General Contractor shall install IPC
cove base , outside corner piece, below all
recessed corner guard areas . "
- ADD the following Note to Detail 14 & 15/A9 :
"The Owner shall furnish and the Contractor
shall install the Treatment Room door and
frame . The General Contractor shall
coordinate and verify with the door
manufacturer (A & L Shielding, Inc. , 268 Old
Lindale Road , P. O. Box 6009, Rome, Georgia
30162-6009; Telephone : ( 706) 235-8822 ; FAX
No . : ( 706 ) 232- 2518 ) in order to adjust
concrete openings to accommodate the final
door and frame. "
M. Sheet A1O/11 - Door Hardware Schedule and Details:
- ADD the following Note to Door Hardware Set
No . 3 :
"l Door "Occupied/Unoccupied" Indicator/Lock"
- ADD the following Note to Detail 9 & 12/A10:
" The General Contractor shall provide
cabinetry with cleats to hold the lead
shielding accessory trays . The lead
shielding accessory trays shall be furnished
by the Owner . "
7 of 10
b) The General Contractor is to apply one (1)
layer of QSC-701 Waterproofing Membrane with
one (1) layer of Q-Board (Protection Board)
above the new Linac supporting area..
c) The General Contractor is to apply one (1)
layer of drainage composite on vertical walls
immediately after installing one (1) layer of
QSC-701 Waterproofing Membrane.
d) Remove Detail Key 8/All and Counterflashing
Notes from Cross-Sections A-A' and D-D' .
e) Remove and disregard any mention of QSC-711
Pre-Pave membrane and applying asphaltic
overlayment in Cross-Sections A-A' , B-B ' and
C-C ' .
f) Remove and disregard any mention of
overlapping QSC-701 Waterproofing Membrane
and QSC-711 Pre-Pave Membrane.
g) The General Contractor shall overlap two (2)
layers of QSC-701 membrane with Q-Board over
one ( 1 ) layer of QSC-701 Membrane with
drainage composite wherever it occurs.
h) The General Contractor shall provide and
install 2" rigid polystyrene perimeter
insulation on all vertical exterior wall
surfaces.
K. Sheet A8/11 - Cabinetry Details:
- REMOVE and REPLACE the following Notes in
Detail 3/A8 :
" Plastic laminate all exposed surfaces
including nosing. "
- REMOVE and ADD the following Notes to
Detail 12/A8 :
"One (1) fixed shelf in the middle with two
(2) adjustable shelving units top and bottom.
The General Contractor shall provide and
install two (1) 1 '-3" doors to fixed storage
cabinetry . All shelves should be able to
accommodate equipment in excess of 50
pounds."
6 of 10
- ADD the following Note to Treatment Room B140,
Elevation 1, 2 and 3 :
"The General Contractor shall provide and
install 1/4" thick x 15" x 24" mild steel
plate required for laser mounting. The
General Contractor shall coordinate work with
the Varian Installation Coordinator. It is
important that the General Contractor first
verify with laser unit manufacturer
(Centralite Patient Positioning Laser by
Diaco, 3191 South 3300 East, Salt Lake City,
Utah 84109; Telephone : ( 801) 467-0050; FAX
No. ( 801) 487-3258 ) prior to ordering the
steel mounting plate. "
- ADD the following Note to Treatment Room B140,
Elevation 1, 3 and 4a:
"The General Contractor shall install IPC
cove base, outside corner piece, below all
recessed corner guard areas."
I . Sheet A6/11 - Interior Elevations - 1/2" & 1/411 :
- ADD the following Note to Corridor B141,
Elevation 4 :
"The General Contractor shall install IPC
cove base, outside corner piece , below all
recessed corner guard areas."
- ADD the following Note to Control Room,
Elevation 2 :
"Owner will furnish and Contractor will
install two (2) retractable computer keyboard
trays in the RMS Unit area."
J. Sheet A7/11 - Waterproofing and Dampproofing-
1/411 :
- ADD and DELETE the following Notes to Cross-
Sections A-A' , B-B' , C-C ' , D-D' and E-E' :
a) The General Contractor is to apply two (2)
layers of QSC-701 waterproofing membrane with
one ( 1) layer of Q-Board (Protection Board)
above new Treatment Room B140 area.
5 of 10
The General Contractor shall provide and
install 2" rigid polystyrene perimeter
insulation continuously on all vertical faces
of exterior walls and beneath all floor
slabs. "
ADD the following General Note to Cross Sections
A-A' , B-B' , C-C ' , D-D' and E-E' :
"The General Contractor is to provide and
install a hung steel drywall suspension
system with R-30 batt insulation below the
new Treatment Room B140 and Linac supporting
ceiling areas. The General Contractor shall
determine the height of the new drywall
suspension system located below the new
concrete ceiling. The General Contractor is
to run all metal stud walls to the ..underside
of the new drywall insulated suspension
system. The General Contractor is to note
that there will be no drywall insulated
suspension system only below the primary
shielding ceiling in the Treatment Room B140
due to lack of space. "
H . Sheet A5/11 - Interior Elevations - 1/2" & 1/4" :
- ADD the following Notes to Treatment Room B140,
Elevation 2 :
" The General Contractor shall provide
cabinetry with cleats to hold the lead
shielding accessory trays . The lead
shielding accessory trays shall be furnished
by the Owner."
- MODIFY Cabinetry Drawing in Treatment Room B140,
Elevation 4b:
The General Contractor shall install one (1)
fixed shelf in the middle of cabinet . The
top and bottom shelves shall be adjustable.
All shelves should be able to accommodate
equipment in excess of 50 pounds. The
General Contractor shall install two (2) 1 ' -
3" doors instead of one (1) door.
4 of 10
"Note: Base frame to be Owner-furnished and
Owner-installed. Owner shall coordinate all
work with Varian Installation Coordinator ,
Mr . Mitchell Spiegel . Varian will be
responsible for leveling the base frame after
Owner installs it into the base frame pit. "
- ADD the following Note to Detail 2/A1 to read
as follows:
"Note: Modulator cabinet shall be furnished
by the Hospital and installed by Varian. The
General Contractor shall assist Varian during
installation."
E. Sheet A2/11 - Partial Floor Plan - 1/8" :
ADD the _following Note regarding saw-cutting of
exterior wall:
"The General Contractor shall saw-cut exterior
wall (9 ' -011 +/- x 71 -1-1/2" +/-) to accommodate
new corridor opening. "
F. Sheet A3/11 - Reflected Ceiling Plan - 1/411 :
ADD the following paging speaker s ) to the
following areas (the symbol shall be PS ) :
The overhead paging speakers shall be centered in
ceiling of Corridor B141 and B143; one (1) speaker
per corridor is required.
G. Sheet A4/11 - Cross-Sections - 1/411 :
- REMOVE the following drawing from Cross-Section
D-D' to reflect as follows:
Remove batt insulation shown on wall between
Electrical Room B142 and existing Mechanical
Room B134.
- ADD the following General Note to Sheet A4/11 :
"The General Contractor shall provide and
install fiberglass batt insulation to all
walls abutting outside areas .
3 of 10
ADD the following to Paragraph 1.04.D.3 :
"3. Suppliers as appropriate to the agenda ,
Owner' s Representatives. "
CHANGES TO THE CONTRACT DRAWINGS AND SPECIFICATIONS
A. Sheet C2/3 - Site Plan:
ADD Note to handicap parking sign to read as
follows :
"Owner to furnish and Contractor to install
handicap parking sign (s) ."
B. Sheet C3/3 - Site Details :
- REMOVE the following Note from Detail 9/C3 :
114 mil poly vapor barrier"
- ADD the following Note to Detail 18/C3:
"NOTE: Owner to furnish and Contractor to
install all exterior signage. "
C. Sheet D1/1 - Site Demolition:
- CHANGE Demolition Note 20 to read as follows :
"The Hospital shall core drill 3" diameter
holes through existing concrete wall to
accommodate new electrical line from existing
Switch Gear Room to new Electrical Room."
- ADD new Note designated 21 to Demolition Note
to read as follows :
" Hospital is responsible for all core
drilling of the existing concrete walls and
slabs to accommodate the new plumbing piping,
heating , ventilating and air conditioning
lines and electrical conduits."
D. Sheet Al/11 - Basement Floor Plan - 1/8" :
- ADD the following Note to Detail 1/A1 to
read as follows:
2 of 10
4A September 8 , 1995
HEALTHCARE
ARCHITECTS INC.
ADDENDUM N0. 2
CORPORATE DIRECTORS Additions and Renovation s
adT r er JmdrY For New Linear Accelerator
Edward L J�odr�,�*,..._
Cooley Dickinson Hospital
smog PRIDmaPAI3 Northampton, Massachusetts
C. J. Thitham ,
PMCIPAW
Mark T. e.,..n r L GENERAL :
Don Belzer
Idehard L Sateanoe
R°` 1a/ VI U°=
Richard P. wi11c A. This Addendum shall supplement , amend and become
part of the Contract Documents . All Bids and the
ZNGnQQM dG ASSOCIATES Construction Contract shall be based on these
me`�
ac St. i�s modifications .
B. The Contractor shall alter his Bid and be bound by
the following changes which affect both the Plans
and Specifications of the Contract Documents .
CHANGES TO THE CONTRACT SPECIFICATIONS
A. Section 07260 - Rigid Fireproofing, Page 1 of 1,
Part 2.01A:
CHANGE Part 2.01A to read as follows:
"Rigid fireproofing shall be Pabco Super Firetemp
"For Interior Use" , 656 South Union Avenue ,
Alliance , Ohio 44601 ; Telephone: (800) 872-0338 ;
FAX No . : (216) 823-8686. "
B. Section 01010 - Summary of Work - Page 2 ,
Paragraph B.3.b:
DELETE Paragraph B.3 .b in its entirety.
C. Section 01200 - Project Meetings - Page 3 ,
Paragraph 1.04C and D :
CHANGE Paragraph 1.04 C to read as follows:
"C . Location of Meetings : Chart Room ,
Maintenance Department , Cooley Dickinson
Hospital , 8 :00 A.M. every Wednesday
morning. "
1 of 10
d< CO MC MW= / HONMAIMMM. 11MAMUSEWS 01080 (419) 696-1612
l
Inc . , 64 Gothic Street , Northampton ,
Massachusetts , until 12 :00 Noon, local time, on or
before September 12, 1995. After such time, all
bids will be privately opened and taken under
advisement."
END OF ADDENDUM
2 of 2
'A September 5, 1995
HEALTHCARE
ARCHITECTS INC.
ADDENDUM NO. 1
CORPORATL DIUCTORS
ROY a BrQWnaJJL Additions and Renovations
Id ward L loamA For New Linear Accelerator
SMOR Pmc3p= Cooley Dickinson Hospital
a. i. Tbuh= Northampton, Massachusetts
PMCD'AW
x rk T. V=nAJA.
D= saaw GENERAL:
130bacd Z Sato m e
Am lavro a Mum
FAchard P. Wk A. This Addendum shall supplement, amend and become
ZNGIIUIMG AM0CIATM part of the Contract Documents . All Bids and the
■ am x. Dw",Px Construction Contract shall be based on these
2mald Q StenhuidYM modifications .
B. The Contractor shall alter his Bid and be bound by
the following changes which affect both the Plans
and Specifications of the Contract Documents .
CHANGES TO THE CONTRACT SPECIFICATIONS :
A. Invitation to Bid - Page 1 of 2, Second Paragraph:
CHANGE the second paragraph to read as follows :
"Sealed bids for the General Contract will be
received at the office of Healthcare Architects
Inc. , 64 Gothic Street, Northampton, Massachusetts
01060, until 12 :00 Noon, local time, on or before
September 12 , 1995 . After such time, the bids
will be privately opened and taken under
advisement . "
B. Instructions to Bidders - Page 1 of 5, Paragraph
A.2 :
CHANGE Paragraph A. 2 to read as follows:
"Sealed bids for the General Contract will be
received at the office of Healthcare Architects
1 of 2
44 GOMC erSar / WRTRAMPM. xA=ACffLT=T3 01060 (40) 666-1612
a F%--%is� �t .7IYl/ l 1P%L
LETTER
AIA DOCUMENT C.810
PROJECT: Addition and Renovations ARCHITECTS
for New Linear Accelerator PROJECT NO: HAI-95-05
Cooley Dickinson Hospital -
Northampton, Massachusetts DATE: September' 8, 1995
r
TO: Massachusetts Department of Public Safety If enclosures are not as noted. please
78 Center Street inform us immediately.Pittsfield, Massachusetts 01201 If checked below, please:
ATTN: Mr. Joseph McEvoy ( ) Acknowledge receipt of enclosures:
L J
. ( ) Return,enclosures m us.
WE TRANSMIT:
( X) fierewith ( ) amder separate cover via
( ) in accordance with your request
-
( 4 approval ( ) distribution to parties ( ) information
( 4 review d comment ( ) record
( ) use ( )
THE FOLLOWING.:
IN) Drawings j ) Shop Dowing Prints ( ) Samples -- —
( ) Specifications ( ) Shop Drawing Reproducibles ( ) Product Literature
( ) Change Order (X) Addenda
COPIES DATE REV.NO. DESCRIPTION ACTION
CODE
1 S4 Drawings
1 9/5/95 Addendum No. 1
1 9/8/95 Addendum No. 2
ACTION, A. Action indicated on item transmitted D. For signature and forwarding at noted below under REMARKS
CODE 6. No action reouired E. See REMARKS below
C. For signature and return to this office
R'MARKS
COPIES TO: (with enclosures)
- Q HEALTHCARE ARCHITECT'S INC.
64 GOTHIC STREET
0 NORTHAMPTON, MASSACHUSETTS 01060
n
❑ 8y: Ki Hoon Hong
AIA DOCL%ifNT G510 tFTTi; 101G . 19'." ED.T40� ' AIAO • CQPV1tICHI '— 19% O%E ►AGE•
�� Ic
r*,. .%CT "! f`F AcCr•'cC75 171; VASS•CJ-01 S AVINN'f N1.% %%acr+IVCTO%.D C.20035