Loading...
36-358 (2) ^ SUSTAINABLE AWeyerhaeuser l FORESTRY INITIATIVE ENGINEERE WOOD 7RODOCTS December 18,2013 Peter J.Van Buren Cowl's Building Supply 125 Sunderland Rd. N.Amherst MA 01059 Re:Sealed Calculations Tech Call#:27633 Jopson Spec 2 Emerson Way Northampton,MA Attached are Forte®calculations and a Job Summary Report for joist,beam,and/or column applications that have been prepared for the above referenced project based on information provided by Peter J.Van Buren-Cowl's Building Supply. The calculations have been identified in the Job Summary Report and by the date and time in the lower right hand corner of each sheet: 12/17/2013 2:52:43 PM 11 pages Many uniformly loaded joist and beam calculations can be verified by referencing the applicable span charts within the appropriate product literature.These common conditions covered by span chart literature may not have been addressed via individual calculations within this package. Each analysis reflects the Trus Joist®product,depth,and size that can structurally support the input loads shown.The professional engineer's seal on this letter verifies that the analyses presented conform to accepted engineering practices and use code-accepted product design values.Although I have not reviewed the project plans or visited the jobsite,we guarantee that our products will meet the strength and deflection requirements as shown in the attached calculations,provided the input model and loading are correct. All notes and design load information shown on these calculations should be reviewed with the building designer and/or the local code official to ensure that the loads,spans,and other conditions are correct and/or acceptable for the specific application.Building inspectors and/or owners should identify the"TJI®","Microllam® LVL","Parallam®PSU,or"TimberStrand®LSL"markings on Trus Joist®products to confirm that this letter is valid for the products actually installed. Please feel free to contact me if there are any questions regarding the analyses,I can be reached at(856)596-5555. Sincerely, ��1VVEgi ny� / too, Robe6A.Kuse7k, Structural Frame Engineer y' o• 'rK?ED 1000 Lincoln Dr.East,Suite 313 • Marlton,NJ 08053 • Phone 856-596-5555 Fax 856-985-9806 Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb1 Ox 0 1075 1075 0 0 0 0 Ox 0 ShMt 2013-Dec-11 09:17:11 wrlghtsoft Right-Suite®Universal 2012 12.0.09 RSU16003 Page 2 ingsUimXMy Documents\Wrightsoft HVAC\benchmark emerson#2.rup Calc=MJ8 Front Doorfaces: - - W rightsoft Duct System Summary oat 91 Emerson way Entire House By: SWIFT RIVER H.V.A.C. 221 N.LIBERTY ST,BELCHERTOWN,MA 01007 Phone:413-323-4123 Fax:413-323-6314 Email:SWIFT4123@AOL.COM Project • • For: benchmark custom homes Heating Cooling External static pressure 0.10 in H2O 0.10 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.10 in H2O 0.10 in H2O Supply/return available pressure 0.05/0.05 in H2O 0.05/0.05 in H2O Lowest friction rate 0 in 1100ft 0 in/100ft Actual air flow 1075 cfm 1075 cfm Total effective length(TEL) 0 ft Supply Detail Table Design Htg Clg Design Diam H x W Duct Actual Fig.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk basement 1 h 1389 91 64 0 0 Ox 0 ShMt 0 0 basement 1-A h 1389 91 64 0 0 Ox 0 ShMt 0 0 basement 2 h 975 85 45 0 0 Ox 0 ShMt 0 0 bed 2 h 2229 113 102 0 0 Ox 0 ShMt 0 0 bed 3 h 1570 76 72 0 0 Ox 0 ShMt 0 0 bed 3 closet h 512 26 23 0 0 Ox 0 ShMt 0 0 dining c 1219 49 56 0 0 Ox 0 ShMt 0 0 dogshed h 987 55 45 0 0 OX 0 ShMt 0 0 foyer h 1212 61 55 0 0 Ox 0 ShMt 0 0 kit c 1295 7 59 0 0 Ox 0 ShMt 0 0 laundry c 962 40 44 0 0 Ox 0 ShMt 0 0 living c 3574 121 164 0 0 Ox 0 ShMt 0 0 master bath c 1665 43 76 0 0 Ox 0 ShMt 0 0 master bed c 1735 52 79 0 0 Ox 0 ShMt 0 0 mud h 295 21 13 0 0 Ox 0 ShMt 0 0 mud 2 h 364 27 17 0 0 Ox 0 ShMt 0 0 nook h 822 55 38 0 0 Ox 0 ShMt 0 0 up bath c 479 18 22 0 0 Ox 0 ShMt 0 0 upper hall c 121 5 6 0 0 Ox 0 ShMt 0 0 upper staircase h 695 40 32 0 0 Ox 0 ShMt 0 0 Bold/italic values have been manually overridden 2013-Dec-11 09:17:11 wrightsOft Right-Suite®Universal 2012 12.0.09 RSU16003 Page 1 11 Xi ...ingswim\My Documents\Wrightsoft HVAC\benchmark emerson#2.rup Calc=MJ8 Front Door faces: BASEMENT basement 2 K85 cfm basement 1 R91 C491 cfm unescavated Job#: 91 Emerson way SWIFT RIVER H.V.A.C. Scale: 1 : 80 Performed for: Page 3 benchmark custom homes 221 N. LIBERTY ST RightSuite®Universal 2012 BELCHERTOWN, MA 01007 12.0.09 RSU16003 Phone:413-3234123 Fax:413-323-6314 2013-Dec-1 109AT40 ...ft HVAC\benchmark emerson#2.rup SWI FT4123 @AOL.COM FIRST FLOOR laundry mud mud 2 �44 cfm 921 cf EK27 cfm nook CK 55 cfm 11 164 cfm kit 1075 cfm 59 cfm ara foyer 61 cfm dining 56 cfm Ll"_ Job#: 91 Emerson way SWIFT RIVER H.V.A.C. Scale: 1 : 80 Performed for: Page 2 benchmark custom homes 221 N. LIBERTY ST RightSuite®Universal 2012 BELCHERTOWN, MA 01007 12.0.09 RSU16003 Phone:413-323-4123 Fax:413-323-6314 2013-Dec-1109:17:40 ft HVAC\benchmark emerson#2.rup SWIFT4123 @AOL.COM 4e_ SECOND FLOOR master bed master bath 76 cfm 79 cfm bed 2 upper hall up bath R22 cfm 113 cfm K6 cfm upper staircase EK40 cfm do shed bed 3 55 cfm R76 cfm bed 3 closet 26 cf Job#: 91 Emerson way SWIFT RIVER H.V.A.C. Scale: 1 : 80 Performed for: Page 1 benchmark custom homes 221 N. LIBERTY ST RightSuite®Universal 2012 BELCHERTOWN, MA 01007 12.0.09 RSU16003 Phone:413-323-4123 Fax:413-323-6314 2013-Dec-1109:1740 ft HVAC\benchmark emerson#2.rup SWIFT4123 AOL.COM + wrightsoft- Right-M Worksheet Job: 91 Emerson way Entire House Date: By: SWIFT RIVER H.V.A.C. 221 N.LIBERTY ST,BELCHERTOWN,MA 01007 Phone:413-323-4123 Fax:413-323-6314 Email:SWIFT4123@AOL.COM 1 Room name basement 1 basement 2 2 Exposed wall 87.0 ft 31.0 ft 3 Room height 1.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 26.0 x 34.0 ft 22.0 x 9.0 ft 5 Room area 884.0 ft' 198.0 ft2 Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/W*F) I (Btuh/ft') I or perimeter (ft) I (Btuh) I or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12F-0sw 0.065 n 4.42 0.83 26 -27 -120 -23 176 142 627 118 4A5-2ov 0.470 n 31.96 11.57 53 0 1702 616 13 0 419 152 11D0 0.390 n 26.52 9.36 0 0 0 0 21 21 557 197 12F-0sw 0.065 a 4.42 0.83 34 20 89 17 0 0 0 0 11 4A5-2ov 0.470 a 31.96 34.74 14 0 443 482 0 0 0 0 yl 12F-0 sw 0.065 s 4.42 0.83 26 26 115 22 D 0 0 0 1! , 4A5-2ov 0.470 s 31.96 19.10 0 0 0 0 D 0 0 0 11 DO 0.390 s 26.52 9.36 0 0 0 0 D 0 0 0 y/ 12F-0 sw 0.065 w 4.42 0.83 1 1 4 1 72 72 318 60 I-G 4A5-2ov 0.470 w 31.96 34.74 0 0 0 0 0 0 0 0 C 1613-38ad 0.026 1.77 1.24 420 420 743 519 0 0 0 0 F 19A-0bsco 0.295 - 7.54 1.33 884 884 6662 1176 198 198 1492 263 61 c)AED excursion 1 -110 -38 Envelope loss/gain 9637 2699 1 1 3414 751 12 a) Infiltration 454 79 1295 224 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 10092 2778 4709 975 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 10092 2778 4709 975 15 Dud loads -0% 0% 0 0 -0% 0% 0 0 Total room load 1 1 1 1009821 21781 1 1 47851 9451 1 1 Air required(cfm) Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Dec-1 10 wrrghtsoft Right-Suite®Universal 2012 12.0.09 RSU16003 Page10 ACS 1a ...ings\Jim\My Documents\Wrightsoft HVAC\benchmarlc emerson#2.rup Calc=MJ8 Front Door faces: - + wriightsoft` Right-M Worksheet Job: 91 Emerson way Entire House Date: By: SWIFT RIVER H.V.A.C. 221 N.LIBERTY ST,BELCHERTOWN,MA 01007 Phone:413-323-4123 Fax:413-3236314 Email:SWIFT4123 @AOL.COM 1 Room name bed 2 dogshed 2 Exposed wall 52.0 It 24.0 ft 3 Room height 9.0 It heat/cool 8.0 It heat/cool 4 Room dimensions 22.0 x 16.0 It 8.0 x 8.0 ft 5 Room area 352.0 ft' 64.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Bt uh/ft'-°F) I (Btuh/ft') I or perimeter (ft) I (Btuh) I or perimeter (ft) I (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12F-Osw 0.065 n 4.42 0.83 198 198 875 165 0 0 0 0 4A5-2ov 0.470 n 31.96 11.57 0 0 0 0 0 0 0 0 �D 11 DO 0.390 n 26.52 9.36 0 0 0 0 0 0 0 0 12F-Osw 0.065 a 4.42 0.83 0 0 0 0 64 64 283 53 11 4A5-2ov 0.470 a 31.96 34.74 0 0 0 0 0 0 0 0 12F-0sw 0.065 s 4.42 0.83 126 126 557 105 64 42 183 35 4A5-2ov 0.470 s 31.96 19.10 0 0 0 0 23 0 719 430 11 DO 0.390 s 26.52 9.36 0 0 0 0 0 0 0 0 12F-0sw 0.065 w 4.42 0.83 144 131 577 109 64 64 283 53 t-G 4A5-2ov 0.470 w 31.96 34.74 14 0 431 469 0 0 0 0 C 1613-38ad 0.026 1.77 1.24 352 352 622 435 64 64 113 79 F 19A-Obsco 0.295 7.54 1.33 107 107 806 142 64 64 482 85 61 c)AED excursion 1511 1 1 1 78 Envelope loss/gain 3869 1576 1 1 2064 813 12 a) Infiltration 2444 423 1003 174 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliancestother 0 0 Subtotal(lines 6 to 13) 6313 2229 3067 987 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 6313 2229 3067 987 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load Air required(cfm) I I I 61131 21021 I I 30551 9451 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. � 2013Dec-1109:17:10 - wreghtsof Rig ht-Su RSU16003 Page 9 ...ings\Jim\My Documents\Wrightsoft HVAC\benchmark emerson#2.rup Calc=MJ8 Front Door faces: +- wrightsoft Right-J® Worksheet Job: 91 Emerson way Entire House Date: By: SWIFT RIVER HN.A.C. 221 N.LIBERTY ST,BELCHERTOWN,MA 01007 Phone:413-323-4123 Fax:413-323-6314 Email:SWIFT4123 @AOL.COM 1 Room name upper staircase bed 3 closet 2 Exposed wall 13.0 ft 11.0 It 3 Room height 8.0 It heat/cool 8.0 ft heat/cool 4 Room dimensions 13.0 x 7.0 ft 7.0 x 4.0 It 5 Room area 91.0 ft' 28.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft'-°F) I (Btuh/ft') ( or perimeter (ft) I (Btuh) I or perimeter (ft) I (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12F-Osw 0.065 n 4.42 0.83 0 0 0 0 0 0 0 0 1(___G 4A5-2ov 0.470 n 31.96 11.57 0 0 0 0 0 0 0 0 -p 11 DO 0.390 n 26.52 936 0 0 0 0 0 0 0 0 V+1 12F-Osw 0.065 a 4.42 0.83 56 56 248 47 32 32 141 27 11 I--G 4A5-2ov 0.470 a 31.96 34.74 0 0 0 0 0 0 0 0 12F-Osw 0.065 s 4.42 0.83 48 35 154 29 56 43 190 36 4A5-2ov 0.470 s 31.96 19.10 13 0 419 251 13 0 419 251 11 DO 0.390 s 26.52 9.36 0 0 0 0 0 0 0 0 yl 12F-Osw 0.065 w 4.42 0.83 0 0 0 0 0 0 0 0 I- G 4A5-2ov 0.470 w 31.96 34.74 0 0 0 0 0 0 0 0 C 166-38ad 0.026 1.77 1.24 91 91 161 112 28 28 50 35 F 19A-Obsco 0.295 7.54 1.33 91 91 686 121 28 28 211 37 6 c)AED excursion 411 1 1 48 Envelope loss/gain 1668 601 1 1 1011 433 12 a) Infiltration 543 94 460 80 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 2211 695 1471 512 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2211 695 1471 512 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 1 1 1 22401 6321 1 1 1471 261 5231 1 ( Air required(cfm) Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wriightacsft Ri ht-Suite®Universal 201212.0.09RSU16003 2013Dec-1109:17:10 .. g Page 8 ingsWim\My Dorwments\Wrightsoft HVAClbenchmark emerson#2.rup Calc=MJ8 Front Door faces: wrightsoft, Right-J® Worksheet Job: 91 Emerson way Entire House Date: By: SWIFT RIVER H.V.A.C. 221 N.LIBERTY ST,BELCHERTOWN,MA01007 Phone:413-323-4123 Fax:413-323-6314 Email:SWIFT4123@-AOL.00M 1 Room name master bath up bath 2 Exposed wall 25.0 It 7.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 10.0 x 14.0 ft 9.0 x 6.0 ft 5 Room area 140.0 ftz 54.0 ft' Ty Construction U-value Or I HTM I Area (ft') I Load I Area (ft2) I Load number (Btuh/Wt- F) (Btuh/ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Vt/ 12F-0sw 0.065 n 4.42 0.83 80 80 354 67 0 0 0 0 II-_pG 4A5-2ov 0.470 n 31.96 11.57 0 0 0 0 0 0 0 0 11 DO 0.390 n 26.52 9.36 0 0 0 0 0 0 0 0 12F-Osw 0.065 a 4.42 0.83 112 104 460 87 48 40 177 33 11 4A5-2ov 0.470 a 31.96 34.74 8 0 256 278 8 0 256 278 yl 12F-Osw 0.065 s 4.42 0.83 8 8 35 7 0 0 0 0 LI-_( 4A5-2ov 0.470 s 31.96 19.10 0 0 0 0 0 0 0 0 p� 11 DO 0.390 s 26.52 9.36 0 0 0 0 0 0 0 0 y/ 12F-Osw 0.065 w 4.42 0.83 0 0 0 0 8 8 35 7 I--G 4A5-2ov 0.470 w 31.96 34.74 0 0 0 0 0 0 0 0 C 168-38ad 0.026 1.77 1.24 140 140 248 173 54 54 95 67 F 19A-Obsco 0.295 - 7.54 1.33 0 0 0 0 18 18 136 24 61 c)AED excursion 1 -271 1 1 1 20 Envelope loss/gain 1352 584 1 1 699 429 12 a) Infiltration 1045 181 293 51 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 900 0 Subtotal(lines 6 to 13) 2396 1665 991 479 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2396 1665 991 479 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 1 1 Total room load 1 1 1 23431 166551 1 1 9981 4221 Air required(dm) Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsaft Ri ht-Suite®Universal 2012 12.0.09 RSU16003 2013-Dec-1 1 09:17:10 g Page 7 i9C_, ings\Jim\My Documents\Wrightsoft HVAClbenchmark emerwn#2.rup Calc=MJ8 Front Door faces: wrightsoft Right-M Worksheet Job: 91 Emerson way Entire House Date: By: SWIFT RIVER H.V.A.C. 221 N.LIBERTY ST,BELCHERTOWN,MA 01007 Phone:413-323-4123 Fax:413-323-6314 Email:SWIFT4123 @AOL.COM 1 Room name upper hall bed 3 2 Exposed wall 1.0 ft 26.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 16.0 x 5.0 ft 12.0 x 14.0 ft 5 Room area 80.0 ft' 168.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft'-°F) (Btuh/ft') I or perimeter (ft) I (Btuh) I or perimeter (ft) (Btuh) Heat Cool Gross N/P/S j Heat I Cool j Gross I N/P/S j Heat Cool 6 12F-Osw 0.065 n 4.42 0.83 8 8 35 7 0 0 0 0 4A5-2ov 0.470 n 31.96 11.57 0 0 0 0 0 0 0 0 11D0 0390 n 26.52 9.36 0 0 0 0 0 0 0 0 V" 12F-Osw 0.065 a 4.42 0.83 0 0 0 0 24 24 106 20 11 L-G 4A5-2ov 0.470 a 31.96 34.74 0 0 0 0 0 0 0 0 V)/� 12F-0sw 0.065 s 4.42 0.83 0 0 0 0 96 69 307 58 ! pG 4A5-2ov 0.470 s 31.96 19.10 0 0 0 0 27 0 851 509 11 DO 0.390 s 26.52 9.36 0 0 0 0 0 0 0 0 12F-0 w 0.065 w 4.42 0.83 0 0 0 0 88 88 389 73 4A5-2ov 0.470 w 31.96 34.74 0 0 0 0 0 0 0 0 C 16B-38ad 0.026 1.77 1.24 80 80 141 99 168 168 297 207 F 19A-Obscp 0.295 - 7.54 1.33 10 10 75 13 157 157 1183 209 61 c)AED excursion 1 -51 1 1 1 76 Envelope loss/gain 252 114 3133 1152 12 a) Infiltration 42 7 1086 188 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal(lines 6 to 13) 294 121 4219 1570 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 294 121 4219 1570 15 Dud loads _0% 0% 0 0 -0% 0% 0 0 Total room load 1 1 2951 121 1 1 42761 15721 1 1 Air required(dm) Calculations approved by ACCA to meet all reouirements of Manual J 8th Ed. 2013-Dec-1t 09:17:10 wrrghtsoft Right-Suite®Universal 2012 12.0.09 RSU16003 Page 6 ingsUim\My Documents\Wrightsoft HVACibenchmark emerson#2.rup Calc=MJS Front Door faces: wrightsoft- Right-M Worksheet Job: 91 Emerson way Entire House Date: By: SWIFT RIVER H.V.A.C. 221 N.LIBERTY ST,BELCHERTOWN,MA 01007 Phone:413-323-4123 Fax:413-323-6314 Email:SWIFT4123 @AOL.COM 1 Room name foyer master bed 2 Exposed wall 26.0 It 23.0 It 3 Room height 9.0 It heat/cool 8.0 It heat/cool 4 Room dimensions 14.0 x 12.0 It 15.0 x 15.0 It 5 Room area 168.0 ft' 225.0 ft' Ty Construction U-value Or I HTM Area (ft') I Load I Area (ft') I Load number (Btuh/f t'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12F-Osw 0.065 n 4.42 0.83 0 0 0 0 120 93 413 78 4A5-2ov 0.470 n 31.96 11.57 0 0 0 0 27 0 851 308 11 DO 0.390 n 26.52 9.36 0 0 0 0 0 0 0 0 y! 12F-Osw 0.065 a 4.42 0.83 108 93 411 77 8 8 35 7 11 L -G 4A5-2ov 0.470 a 31.96 34.74 15 0 479 521 0 0 0 0 12F-0sw 0.065 s 4.42 0.83 126 96 424 80 0 0 0 0 4A5-2ov 0.470 s 31.96 19.10 9 0 288 172 0 0 0 0 11D0 0.390 s 26.52 9.36 21 21 557 197 0 0 0 0 12F-0 w 0.065 w 4.42 0.83 0 0 0 0 56 56 248 47 4A5-2ov 0.470 w 31.96 34.74 0 0 0 0 0 0 0 0 C 166-38ad 0.026 1.77 1.24 1 1 2 1 225 225 398 278 F 19A-ObscD 0.295 7.54 1.33 0 0 0 0 0 0 0 0 61 c)AED excursion 1 -48 1 1 -68 Envelope loss/gain 2161 1000 1 1 1944 1 648 12 a) Infiltration 1222 212 961 166 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 4 920 Appliances/other 0 0 Subtotal(lines 6 to 13) 3383 1212 2905 1735 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3383 1212 2905 1735 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total rom load 1 Airrequiir d(cfm) 1 1 3361 12551 1 1 295221 17791 ply Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. r- wrightseft Rig ht-Su Universal 2012 12.0.09 RSU16003 2013-Dec-11 09:17:10 g Page 5 ingsUim\My Documents\Wrightsoft HVAC\benchmark emerson#2.rup Calc=MJ8 Front Door faces: wrightsoft- Right-J® Worksheet Job: 91 Emerson way Entire House Date: SWIFT RIVER H.V.A.C. By: 221 N.LIBERTY ST,BELCHERTOWN,MA 01007 Phone:413-323-4123 Fax:413-323-6314 Email:SWIFT4123@ AOL.COM 1 Room name dining living 2 Exposed wall 18.0 ft 34.0 It 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 12.0 x 13.0 ft 14.0 x 20.0 ft 5 Room area 156.0 ft' 280.0 ft' Ty I Construction U-value Or HTM Area (ft') Load Area (W) Load number (Btuh/ft'-°F) I (Btuh/f[') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S j Heat I Cool j Gross I N/P/S j Heat Cool 6 W 12F-Osw 0.065 n 4.42 0.83 0 0 0 0 126 84 371 70 4A5-20v 0.470 n 31.96 11.57 0 0 0 0 42 0 1342 486 ll��--DODO 11 DO 0.390 n 26.52 9.36 0 0 0 0 0 0 0 0 kt/ 12F-Osw 0.065 a 4.42 0.83 27 27 119 22 180 147 650 122 11 �-G 4A5-2ov 0.470 a 31.96 34.74 0 0 0 0 33 0 1055 1147 12F-Osw 0.065 s 4.42 0.83 108 66 292 55 0 0 0 0 4A5-20v 0.470 s 31.96 19.10 42 0 1342 802 0 0 0 0 1100 0.390 s 26.52 9.36 0 0 0 0 0 0 0 0 y/ 12F-Osw 0.065 w 4.42 0.83 27 27 119 22 0 0 0 0 --G 4A5-2ov 0.470 w 31.96 34.74 0 0 0 0 0 0 0 0 C 1613-38ad 0.026 1.77 1.24 0 0 0 0 196 196 347 242 F 19A-Obsco 0.295 - 7.54 1.33 0 0 0 0 182 182 1372 242 61 c)AED excursion 1 1 170 -141 Envelope loss/gain 1 1873 1072 1 1 5136 2168 12 a) Infiltration 846 146 1598 277 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 900 Subtotal(lines 6 to 13) 2719 1219 6734 3574 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2719 1219 6734 3574 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 1 1 Air equredl(cfm) 1 1 1 2119191 491 1256 1 1 61211 31641 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .1, 2013-Dec-11 09:17:10 -r righ Q Rig ht-Suite®Universal 2012 12.0.09 RSU 16003 Page 4 ..ings\Jim\My Documents\Wrightsoft HVAC\benchmark emerson*2.rup Calc=MJ8 Front Door faces: wriightsoft Right-J® Worksheet Job: 91 Emerson way Entire House Date: SWIFT RIVER HN.A.C. By: 221 N.LIBERTY ST,BELCHERTOWN,MA01007 Phone:413-323-4123 Fax:413-323-6314 Email:SWIFT4123@AOL.COM 1 Room name nook kit 2 Exposed wall 12.0 ft 0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 12.0 x 10.0 ft 12.0 x 12.0 ft 5 Room area 120.0 ft' 144.0 ft2 Ty I Construction U-value Or I HTM I Area (ft2) I Load I Area (ft2) I Load number (Btuh/f t'-°F) (Bt WWI or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12F-Osw 0.065 n 4.42 0.83 108 75 329 62 0 0 0 0 4A5-20v 0.470 n 31.96 11.57 33 0 1069 387 0 0 0 0 11D0 0.390 n 26.52 9.36 0 0 0 0 0 0 0 0 12F-Osw 0.065 a 4.42 0.83 0 0 0 0 0 0 0 0 11 4A5-2ov 0.470 a 31.96 34.74 0 0 0 0 0 0 0 0 Vj/ 12F-Osw 0.065 s 4.42 0.83 0 0 0 0 0 0 0 0 ���p 4A5-2ov 0.470 s 31.96 19.10 0 0 0 0 0 0 0 0 11 D0 0.390 s 26.52 9.36 0 0 0 0 0 0 0 0 V)J 12F-Osw 0.065 w 4.42 0.83 0 0 0 0 0 0 0 0 t-G 4A5-2ov 0.470 w 31.96 34.74 0 0 0 0 0 0 0 0 C 16B-38ad 0.026 1.77 124 120 120 212 148 55 55 97 68 F 19A-Obsco 0.295 7.54 1.33 120 120 904 160 36 36 271 48 61 c)AED excursion 1 1 -32 -51 Envelope loss/gain 2515 724 1 1 369 65 12 a) Infiltration 564 98 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 1000 Subtotal(lines 6 to 13) 3079 822 369 1295 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3079 822 369 1295 15 Dud loads -0% 0% 0 0 -0% 0% 0 0 Total rom load 1 ( Air requi d(cfm) ( I I 30551 8221 38 I I 3671 12591 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrigFrr#sof# 2013-Dec-1109:17:10 Af _: . Right-Suite®Universal 201212.0.09RSU16003 Page ings\Jim\My Documents\Wrightsoft HVAC\benchmark emerson#2.rup Calc=MJ8 Front Door faces: + wrightsoft Right-J® Worksheet Job: 91 Emerson way Entire House Date: By: SWIFT RIVER H.V.A.C. 221 N.LIBERTY ST,BELCHERTOWN,MA 01007 Phone:413-3234123 Fax:413-323-6314 Email:SWIFT4123@,AOL.COM 1 Room name mud mud 2 2 Exposed wall 6.0 ft 8.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 6.0 x 8.0 It 8.0 x 8.0 ft 5 Room area 48.0 ft' 64.0 ft' Ty Construction U-value Or HTM Area If t') Load Area (f t') Load number (Btuh/ft'-°F) I (Bt uh/fI') I or perimeter (ft) I (Btuh) I or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12F-Osw 0.065 n 4.42 0.83 54 46 202 38 72 64 281 53 4A5-2ov 0.470 n 31.96 11.57 8 0 266 96 8 0 266 96 11 DO 0.390 n 26.52 9.36 0 0 0 0 0 0 0 0 12F-0sw 0.065 a 4.42 0.83 0 0 0 0 0 0 0 0 11 4A5-2ov 0.470 a 31.96 34.74 0 0 0 0 0 0 0 0 V/ 12F-Osw 0.065 s 4.42 0.83 0 0 0 0 0 0 0 0 �-G 4A5-2ov 0.470 s 31.96 19.10 0 0 0 0 0 0 0 0 III------DDD 11130 0.390 s 26.52 9.36 0 0 0 0 0 0 0 0 12F-Osw 0.065 w 4.42 0.83 0 0 0 0 0 0 0 0 4A5-2ov 0.470 w 31.96 34.74 0 0 0 0 0 0 0 0 C 166-38ad 0.026 1.77 1.24 48 48 85 59 64 64 113 79 F 19A-Obsw 0.295 7.54 1.33 48 48 362 64 64 64 482 85 61 c)AED excursion 1 -12 -14 Envelope loss/gain 915 246 1 1 1143 299 12 a) Infiltration 282 49 376 65 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1197 295 1519 364 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1197 295 1519 364 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total L 1 Airrequi red load 1 1 1 11211 2131 1 1 1527 317 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. I�,.A.� wrrghtsoTt Right-Suite®Universal 2012 12.0.09 RSU16003 2013-Dec-1 1 Page 2 ings\Jim\My Documents\Wrightsoft HVAC\benchmark emerson#2.rup Calc=MJB Front Doorfaces: + r wrightsdit Right-M Worksheet Job: 91 Emerson way Entire House Date: SWIFT RIVER H.V.A.C. By: 221 N.LIBERTY ST,BELCHERTOWN,MA 01007 Phone:413-323-4123 Fax:413-323-6314 Email:SWIFT4123@4OL.COM 1 Room name Entire House laundry 2 Exposed wall 420.0 ft 16.0 It 3 Room height 6.6 R d 9.0 R heat/cool 4 Room dimensions 8.0 x 8.0 ft 5 Room area 3328.0 fN 64.0 ft2 Ty Construction U-value Or I HTM I Area (ft') ( Load I Area (ft') I Load number (Btuh/W'F) (Btuh/ft) or perimeter (R) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12F-0sw 0.065 n 4.42 0.83 1040 826 3650 687 72 64 283 53 4A5-20v 0.470 n 31.96 11.57 193 0 6172 2234 8 0 256 93 1111130 0.390 n 26.52 9.36 21 21 557 197 0 0 0 0 12F-Osw 0.065 a 4.42 0.83 693 615 2719 512 0 0 0 0 11 4A5-2ov 0.470 a 31.96 34.74 78 0 2489 2706 0 0 0 0 12F-0sw 0.065 s 4.42 0.83 658 511 2257 425 0 0 0 0 4A5-2ov 0.470 s 31.96 19.10 126 0 4039 2414 0 0 0 0 11130 0.390 s 26.52 9.36 21 21 557 197 0 0 0 0 V+/ 12F-Osw 0.065 w 4.42 0.83 532 519 2292 431 72 72 318 60 L---G 4A5-2ov 0.470 w 31.96 34.74 14 0 431 469 0 0 0 0 C 168-38ad 0.026 1.77 1.24 2170 2170 3837 2680 64 64 113 79 F 19A-Obsco 0.295 7.54 1.33 2071 2071 15607 2754 64 64 482 85 61 c)AED excursion 0 -38 Envelope loss/gain 1 44606 15705 1 1 1452 332 12 a) Infiltration 15267 2643 752 130 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 8 1840 0 0 Appliances/other 3300 500 Subtotal(lines 6 to 13) 59874 23488 2204 962 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 59874 23488 2204 962 15 Dud loads 0% 0% 0 0 -0% 0% 0 0 Total Air requodl(dm) I I I 590751 210851 I I 22401 9441 Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed. 2013-Dec-1109:17:10 A -Pk ft WrightSQ ' Right-Suite®Universal 2012 12.0.09 RSU 16003 Page 1 ..ings\Jim\My Documents\Wrightsoft HVAC\benchmark emerson*2.rup Calc=MJ8 Front Doorfaces: AED Assessment Job: 91 Emerson way wrightsoft Date: Entire House By: SWIFT RIVER HN.A.C. 221 N.LIBERTY ST,BELCHERTOWN,MA 01007 Phone:413-323-4123 Fax:413-3236314 Email:SWIFT4123@AOL.COM Project • • For: benchmark custom homes Design Conditions Location: Indoor: Heating Cooling Springfield Westover AFB, MA, US Indoor temperature(TF) 68 75 Elevation: 190 ft Design TD(TF) 68 12 Latitude: 42'N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 46.9 24.1 Dry bulb(T) 0 87 Infiltration: Dailyrange(TF) - 19 ( M ) Wetbulb(°F) - 71 Wind speed(mph) 15.0 7.5 Test for • ' • uate Expo Hourly Glazing Load 12, 11, 10, 8, 7, 6, 5 4, 3, 2, J, N 4 2014 1 i 0 8 9 10 11 12 13 14 15 16 17 18 19 20 FbrdD3j ,e Hourly Aaage AMlimt Maximum hourly glazing load exceeds average by 24.8%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh wrl htsaft' 2013Dec-1109:17:10 Right-Suite®Universal 2012 12.0.09 RSU16003 Page 1 ,CC A _.ingsXJim\My Documents\Wrightsoft HVAC\benchmark emerson#2.rup Calc=MJ8 Front Doorfaces: wrightsoft Project Summary 91 Emerson way Da e: Entire House By: SWIFT RIVER H.V.A.C. 221 N.LIBERTY ST,BELCHERTOWN,MA 01007 Phone:413-323-4123 Fax:413-323-6314 Email:SWIFT4123@AOL.COM Project • • For: benchmark custom homes Notes: Design Information Weather: Springfield Westover AFB, MA, US Winter Design Conditions Summer Design Conditions Outside db 0 °F Outside db 87 °F Inside db 68 'F Inside db 75 °F Design TD 68 °F Design TD 12 °F Daily range M Relative humidity 50 % Moisture difference 24 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 59874 Btuh Structure 23488 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 59874 Btuh Use manufacturer's data n Rate/swing multiplier 0.92 Infiltration Equipment sensible load 21609 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 0 Structure 5881 Btuh Ducts 0 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft� 3328 3328 Equipment latent load 5881 Btuh Volume(ft) 21832 21832 Air changes/hour 0.13 0.07 Equipment total load 27490 Btuh Equiv.AVF(cfm) 206 202 Req.total capacity at 0.60 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make rheem Make rheem Trade rheem Trade rheem Model R95pa0701317msa Cond 13ajn36a01 AHRI ref Coil rcflhm3617 AHRI ref Efficiency 80 AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 'F Total cooling 0 Btuh Actual air flow 1075 cfm Actual air flow 1075 cfm Air flow factor 0.018 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0.10 in H2O Static pressure 0.10 in H2O Space thermostat Load sensible heat ratio 0.80 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htscsfft 2013 Deo-11 09:17:10 � Right-SuiteC�J Universal 2012 12.0.09 RSU16003 Page 1 ings\Jim\My Documents\Wrightsoft HVAC\benchmark emerson#2.rup Calc=MJ8 Front Door faces: w INSURANCE COVERAGE: 1 have a current liability insurance policy or its equivalent which meets the requirements of M.G.L.Ch. 112 Yes No❑ If you have checked Yes,indicate the a of coverage by checking the appropriate box below: A liability insurance policy Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. Check One Only Owner ❑ Agent ❑ Signature of Owner or Owner's Agent By checking this box[],I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws.- Duct inspection required prior to insulation installation:YES NO Progress Inspections Date Comments Final Inspection Date Comments T�of nse: By Title ❑Master-Restricted City/Town ❑Joumeyperson Signature of Licensee Permit# ❑Joumeyperson-Restricted License Number: 5?_ Fee$ Check at www.mass.gov/dPi Inspector Signature of Permit Approval Commonwealth of Massaehu Sheet Metal Permit ' 111AM 1 Date: .Estimated Job Cost: $ Permit Fee: $_2z1 _ Plans Submitted: YES NO Plans Reviewed: YES NO Business License# Applicant License# Business Information: Property Owner/Job Location Inf/ormation: Name:� 4)it r ZLer J���/t. Name: rge,d7n4mzck ,, // Street: At Street: City/Town: City/Town: , Telephone: Telephone:�//S jr,� &76q, 1 esevl C i) Photo I.D. re uired/Copy of Photo I.D. attached: YES NO Staff Initial J-1 /M-1-unrestricted license 3-2 /M-2-restricted to dwellin s 3-stories or less and commercial up to 10,000 sq. ft./2-stories or less Residential: 1-2 family Multi-family Condo/Townhouses Other Commercial: Office Retail Industrial Educational Institutional Other Square Footage: under 10,000 sq. ft. mover 10,000 sq. ft. Number of Stories: Sheet metal work to be completed: New Work: C' Renovation: HVAC Metal Watershed Roofing Kitchen Exhaust System Metal Chimney/Vents Air Balancing Provide detailed description of work to be done: 1 File#SM-2014-0042 APPLICANT/CONTACT PERSON SWIFT RIVER HVAC INC ADDRESS/PHONE 221 N LIBERTY ST (413)323-4123 PROPERTY LOCATION 91 EMERSON WAY MAP 36 PARCEL 358 001 ZONE THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Buildiny,Permit Filled out Fee Paid Typeof Construction: SHEETMETAL SFH New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included• Owner/Statement or License 220 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INF99MATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER: § Intermediate Project: Site Plan AND/OR Special Permit with Site Plan Major Project: Site Plan AND/OR Special Permit with Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee rom Elm Street Commission Permit DPW Storm Water Management 6C<4 W,4A— e /-�� Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact the Office of Planning&Development for more information. 91 EMERSON WAY SM-2014-0042 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON IGI GIS#:-- 11762 1 i 6 I 13 --- . Block: 3-- --- --- y i 58 d SHEETMETAL PERMIT -- — — — Lot ool -_ -- -- Permit: SHEETMETAL Category: 1SHEETMETAL Permit# !SM 2014-0042 pERMISSIONIS HEREBY GRANTED TO: -- - -— �Project# JS-20 1 4-001141 Est Cost: 1 Contractor: License: Expires: - - - -- eetmetal-220 'Fee Charged:$25.00 SWIFT RIVER HVAC INC Sh 08/28/2015 iBalance Due:,$.00 Owner: HAMPSHIRE PROPERTY MANAGEMENT #of Flxtures:� Applicant: SWIFT RIVER HVAC INC Dig-Safe-# - _ JA T. 91 EMERSON WAY -- - �UseGroup ConstClass ISSUED ON. 22-Jan-2014 AMENDED ON. EXPIRES ON: TO PERFORM THE FOLLOWING WORK: SHEETMETAL SFH THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fee Type: Receipt No: Date Paid: Check No: Amount: Sheetmetal REC-2014-002978 22-Jan-14 15835 $25.00 212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:ihasbrouck @northamptonma.gov GeoTMS®2014 Des Lauriers Municipal Solutions,Inc.