Loading...
10D-023 Accessory Apt Cellar/Basement39 Florence St Accessory Apartment Gross floor area 899 sq. ft.; cellar is also 899 sq. ft. area. The plans do not show any escape openings in the cellar. Emergency escape openings are required in any occupied cellar or basement. It seems that this would be allowed under 350-10.10 because the space below grade would be defined as a cellar. We would restrict the cellar to utilities, etc and not useable as habitable space. 350-10.10 ACCESSORY APARTMENTS (B) (5): The gross floor area of an accessory apartment (including any additions) shall not be greater than 900 square feet. 350-2.0 DEFINITIONS BASEMENT A portion of a building partly below grade, which has less than 1/3 of its height measured from finished floor to finished ceiling, below the average finished grade of the ground adjoining the building CELLAR A portion of a building, partly or entirely below grade, half or more than 1/2 of its height measured from finished floor to finished ceiling, below the average finished grade of the ground adjoining the building. A cellar is not deemed a story. (See Diagram 1 below.)  FLOOR AREA, GROSS The sum of the gross horizontal area of the several floors including basements of a principal building and its faces of the walls. It does not include cellars; unenclosed porches or attics not used for human occupancy; malls within a shopping center utilized purely for pedestrian circulation and/or decorative purposes between individual shops of the center; any floor space in an accessory or principal building intended and designed for the parking of motor vehicles in order to meet the parking requirements of this chapter; or any such floor space intended or designed for accessory heating, ventilating and air-conditioning equipment.