Loading...
28851-ROSEMUND_NUTTING-RKH-012513-SEALS24 West St.West Hatfield, MA 01088 r.k. Miles, Inc. (413) 247-8300 WORK ORDER # Attn: 28851 Job:ROSEMUND Ordered On:01/21/13 24 NUTTING AVE. NORTHAMPTON, MA ANDY CLOGSTON MANUFACTURERS OF ROOF & FLOOR TRUSSES 181 GOODWIN ST PO BOX 51027 INDIAN ORCHARD, MA 01151 Phone (413) 543-1298 Fax (413) 543-1847 Toll Free (800) 456-0187 PO:RU-48665/ROSEMU Brian TetreaultOur Salesman: Cancellation Date: Sold To: Contractor Copy of Order Phone: Ordered By:ANDY CLOGSTON 01/24/13 ** ** Truss Engineering's Shipping Department should be contacted 5 business days before your optimal delivery date. "Projected Delivery" dates are NOT scheduled ship dates. 02/02/13Projected Delivery By: *REVISED PER 1/17/13 ACTUAL MEASUREMENTS.SPECIAL INSTRUCTIONS: QTYTYPE SPAN LUMBER TOPBOT OVRHG / CANT LEFTRIGHT PITCH TOPBOT TRUSS ID TOTALPRICEPRICEUNITPROFILE ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL 50.0,10.0,0.0,10.0INFORMATION ROOF TRUSS SPACING:24.0 IN. O.C. (TYP.) PLY O/ABASE SPAN SHIPPING WIDTH UNIT WEIGHT LAYOUT BY:BRT01/17/13ON: 01 6.00 0.00 06-00-15 01-00-00 2 X 42 X 4 Jack-Closed 6 06-00-15 04-00-08 20 02 6.00 0.00 04-00-15 01-00-00 2 X 42 X 4 Jack-Closed 6 04-00-15 03-00-08 14 03 6.00 0.00 02-00-15 01-00-00 2 X 42 X 4 Jack-Open 6 02-00-15 02-00-08 7 04 6.00 0.00 08-02-00 01-00-00 2 X 42 X 4Jack-Closed 6 08-02-00 05-01-00 32 04G 6.00 0.00 08-02-00 01-00-00 2 X 42 X 6 JACK-CLOSED 1 08-02-00 05-01-00 43 CJ1 4.24 0.00 11-05-01 01-05-00 2 X 42 X 6 DIAGONAL HIP 3 11-05-01 05-00-07 54 G1 1 6.00 0.00 24-04-00 01-00-0001-00-00 2 X 42 X 6 HIP TRUSS 2 Ply 24-04-00 05-01-00 123 G1A 1 6.00 0.00 24-04-00 01-00-0001-00-00 2 X 42 X 6 HIP TRUSS 2 Ply 24-04-00 05-01-00 123 H1 6.00 0.00 24-04-00 01-00-0001-00-00 2 X 42 X 4 Hip Truss 2 24-04-00 06-01-00 112 T1 6.00 0.00 24-04-00 01-00-0001-00-00 2 X 42 X 4 Common Truss 6 24-04-00 07-01-00 105 T2 6.00 0.00 14-04-00 01-00-00 2 X 42 X 4 COMMON 1 14-04-00 04-07-00 60 T2A 6.00 0.00 14-04-00 01-00-00 2 X 42 X 4 Special Truss 1 14-04-00 04-07-00 60 T2B 6.00 0.00 14-04-00 01-00-00 2 X 42 X 4 Special Truss 1 14-04-00 04-07-00 62 T2C 6.00 0.00 14-04-00 01-00-00 2 X 42 X 4 Special Truss 1 14-04-00 04-07-00 71 T2GE 6.00 0.00 14-04-00 01-00-0001-00-00 2 X 42 X 4 Common Truss 1 14-04-00 04-07-00 57 T3 6.00 0.00 26-00-00 01-00-0001-00-00 2 X 42 X 4 Common Truss 7 26-00-00 07-03-15 91 T3GE 6.00 0.00 26-00-00 01-00-0001-00-00 2 X 42 X 4 GABLE 1 26-00-00 07-03-15 110 ROOF SUB-TOTAL: QTY NOTES PRICEUNITTOTALPRICE ITEMS CATEGORYITEM 24 West St.West Hatfield, MA 01088 r.k. Miles, Inc. (413) 247-8300 WORK ORDER # Attn: 28851 Job:ROSEMUND Ordered On:01/21/13 24 NUTTING AVE. NORTHAMPTON, MA ANDY CLOGSTON MANUFACTURERS OF ROOF & FLOOR TRUSSES 181 GOODWIN ST PO BOX 51027 INDIAN ORCHARD, MA 01151 Phone (413) 543-1298 Fax (413) 543-1847 Toll Free (800) 456-0187 PO:RU-48665/ROSEMU Brian TetreaultOur Salesman: Cancellation Date: Sold To: Contractor Copy of Order Phone: Ordered By:ANDY CLOGSTON 01/24/13 ** ** Truss Engineering's Shipping Department should be contacted 5 business days before your optimal delivery date. "Projected Delivery" dates are NOT scheduled ship dates. 02/02/13Projected Delivery By: QTY NOTES PRICEUNITTOTALPRICE ITEMS CATEGORYITEM 4 HUS26Hanger 3 LUS26Hanger 12 SNP3Hanger 3 THJA26Hanger ITEMS SUB-TOTAL: SUB-TOTAL GRAND TOTAL ***** IMPORTANT NOTE ***** It is the sole responsibility of the retailer to supply all attached drawings and information to their customer for review and approval. Any and all changes must be received by Truss Engineering prior to the cancellation date. Any changes received after cancellation date may result in added charges and delay of order. No response before cancellation date will be perceived as a full approval of order. Truss Engineering is responsible for supplying only the material as listed on the order. Deliveries are F.O.B. our truck to jobsite. Inability to access the jobsite or take delivery of order may result in additional charges. *** THESE DRAWINGS HAVE BEEN REVIEWED AND ARE APPROVED AS AN ORDER *** Approved By:Approval Date: PO #:Requested Delivery Date: T3GE CO N V E N T I O N A L L Y FR A M E D T3( 7) 2- 0 0 - 0 0 7-00-0026-00-00 14 - 0 0 - 0 0 10 - 0 0 - 0 0 14 - 0 0 - 0 0 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 14 - 0 4 - 0 0 24 - 0 4 - 0 0 1- 0 4 - 0 0 36-04-00 Job Number: 28851This non‐structural placement plan is provided for identifying the location of trusses as supplied by Truss Engineering Corporation (TEC). No responsibility is taken or implied by TEC for the structural integrity of the structure below the trusses or the affects of TEC’s product on the structure as a whole. The truss installer shall follow all BCSI recommendations, construction document specifications as well as any site specific requirements to ensure safe and proper installation. No loading shall be applied to trusses until properly and fully installed, including all sheathing, hangers, wall anchors, lateral web bracing (as shown on individual shop drawings), and permanent bracing (as required by the construction documents). Installation contractor shall refer to the individual truss shop drawings for all structural requirements of trusses,including but not limited to bearing locations and requirements, ply to ply nailing, lateral web bracing, and truss spacing. Truss Engineering Corporation strictly adheres to the ‘Standard Responsibilities in the Design of Metal Plate Connected Wood Trusses’ as defined by TPI Chapter 2 (available upon request) regardless of any job specific specifications unless clearly defined otherwise in writing by TEC.This placement plan is Truss Engineering Corporation’sINTERPRETATION of plans and drawings as supplied to us. The building owner/owner’s agent is solely responsible for verifying all dimensions, geometry, loads and load requirements for accuracy and full compliance to construction documents and shall be responsible for notifying TEC immediately of any discrepancies. The building owner/owner’s agent is responsible for coordinating all construction details between trades. Truss Engineering Corporation isNOT responsible for field verification of dimensions or special conditions. No trusses supplied by Truss Engineering Corporation may be cut, drilled, or altered in any way without first contacting TEC and receiving engineering documents allowing such.Quote Number: Q1211232 Drawn By: Brian Tetreault Job Name:Jobsite: ROSEMUND 24 NUTTING AVE. NORTHAMPTONMA Job 28851 Truss T3 Truss Type Common Truss Qty 7 Ply 1 24 NUTTING AVE. NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jan 22 06:55:02 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:tznUJPu9bDpwDX2XJwpBvyyEf4L-AYqT7itjKgD7uUEB2n3zSo8niQ2trUCDeymGrPzsuXd Scale = 1:41.2 T1 T1 B1 W2 W1 W2 W1 B21 2 3 4 5 6 7 9 8 10 11 12 13 14 15 16 17 18 19 5x6 4x6 5x8 1.5x4 4x4 1.5x4 4x6 9-0-0 9-0-0 17-0-0 8-0-0 26-0-0 9-0-0 -1-0-0 1-0-0 6-9-2 6-9-2 13-0-0 6-2-14 19-2-14 6-2-14 26-0-0 6-9-2 27-0-0 1-0-0 0-4-5 6-10-5 7-3-15 0-4-5 6.00 12 Plate Offsets (X,Y): [4:0-3-8,0-2-8], [8:0-4-0,0-3-0] LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL BCDL 38.5 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.830.890.39 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.21-0.460.10 (loc) 8-92-96 l/defl >999>675n/a L/d 240180n/a PLATES MT20 Weight: 91 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5EBOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)2 =1393/0-3-8 (min. 0-2-9)6 =1393/0-3-8 (min. 0-2-9)Max Horz2 =-75(LC 7)Max Uplift2 =-215(LC 9) 6 =-215(LC 10) Max Grav 2 =1615(LC 2) 6 =1615(LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-10=-2657/345, 10-11=-2532/365, 3-11=-2394/368, TOP CHORD2-10=-2657/345, 10-11=-2532/365, 3-11=-2394/368, 3-12=-2286/346, 12-13=-2142/356, 4-13=-2132/367, 4-14=-2132/367, 14-15=-2142/356, 5-15=-2286/346, 5-16=-2394/368, 16-17=-2532/365, 6-17=-2657/345 BOT CHORD 2-9=-225/2248, 9-18=-77/1488, 18-19=-77/1488, 8-19=-77/1488, 6-8=-225/2248WEBS4-8=-88/906, 5-8=-712/187, 4-9=-88/906, 3-9=-712/187 NOTES (12)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0,Interior(1) 2-0-0 to 10-0-0, Exterior(2) 10-0-0 to 13-0-0, Interior(1) 16-0-0 to 24-0-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 38.5 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.8) All bearings are assumed to be SPF No.2 . 9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 2=215, 6=215.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 12) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard Job 28851 Truss T3GE Truss Type GABLE Qty 1 Ply 1 24 NUTTING AVE. NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jan 22 06:55:08 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:tznUJPu9bDpwDX2XJwpBvyyEf4L-?iBlNlyUvW_GcPhLP1AOi3OzhqITFGn50uDa32zsuXX Scale = 1:43.2 T1 T1 B1 B2 ST6 ST5 ST4 ST3 ST2 ST1 ST5 ST4 ST3 ST2 ST1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 26 25 24 23 22 21 20 19 18 17 16 27 28 29 30 31 32 33 34 35 36 4x4 3x4 3x4 5x6 26-0-0 26-0-0 -1-0-0 1-0-0 13-0-0 13-0-0 26-0-0 13-0-0 27-0-0 1-0-0 0-4-5 6-10-5 7-3-15 0-4-5 6.00 12 Plate Offsets (X,Y): [19:0-3-0,0-3-0] LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL BCDL 38.5 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.090.050.19 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.000.000.01 (loc) 141514 l/defl n/rn/rn/a L/d 12090n/a PLATES MT20 Weight: 111 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5EBOT CHORD 2 X 4 SPF No.2OTHERS2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS All bearings 26-0-0.(lb) - Max Horz2= -75(LC 7)Max UpliftAll uplift 100 lb or less at joint(s) 2, 14, 22, 23, 24, 25, 26, 20, 19, 18, 17, 16Max Grav All reactions 250 lb or less at joint(s) 21, 25, 17 except 2=272(LC 2), 14=272(LC 2), 22=334(LC 14), 23=312(LC 3), 24=256(LC 14), 26=330(LC 14), 20=334(LC 15), 19=312(LC 4), 18=256(LC 15), 16=330(LC 15) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.WEBS7-22=-294/141, 6-23=-268/96, 3-26=-262/137, 9-20=-294/141, WEBS7-22=-294/141, 6-23=-268/96, 3-26=-262/137, 9-20=-294/141, 10-19=-268/96, 13-16=-262/137 NOTES (16) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Corner(3) -1-0-0 to 2-0-0,Exterior(2) 2-0-0 to 10-0-0, Corner(3) 10-0-0 to 13-0-0, Exterior(2) 16-0-0 to 24-0-0zone; cantilever left and right exposed ;C-C for members and forces & MWFRS forreactions shown; Lumber DOL=1.60 plate grip DOL=1.602) Truss designed for wind loads in the plane of the truss only. For studs exposed towind (normal to the face), see Standard Industry Gable End Details as applicable, orconsult qualified building designer as per ANSI/TPI 1.3) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 38.5 psf on overhangs non-concurrent with other live loads. 6) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.7) All plates are 1.5x4 MT20 unless otherwise indicated.8) Gable requires continuous bottom chord bearing. 9) Gable studs spaced at 2-0-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.11) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.12) All bearings are assumed to be SPF No.2 . 13) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) 2, 14, 22, 23, 24, 25, 26, 20, 19, 18, 17, 16.14) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 15) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 16) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard NailedNailed SNP3 Na i l e d Na i l e d SN P 3 Na i l e d Na i l e d NailedNailed SN P 3 SNP3 NailedNailed SNP3 Na i l e d Na i l e d SN P 3 SN P 3 SNP3 SNP3 SN P 3 SNP3 SN P 3 . . THJA26 THJA26 LUS26 LUS26 LUS26 No S o l n . HU S 2 6 HUS26 HU S 2 6 THJA26 HU S 2 6 G1 H1 CJ1 CJ1 01 02 03 010203 010203 01 02 03 G1 A H1 CJ1 04 01 02 03 01 02 03 04G T2 G E T2 T2 A T2 B T2 C T1(6)04(5) 34-04-00 36-04-00 10 - 0 0 - 0 0 14 - 0 4 - 0 0 24 - 0 4 - 0 0 24 - 0 4 - 0 0 2- 0 2 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 2 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 8-02-00 2-02-00 2-00-00 2-00-00 2-00-00 2-00-00 8-02-00 2- 0 0 - 0 0 Job Number: 28851This non‐structural placement plan is provided for identifying the location of trusses as supplied by Truss Engineering Corporation (TEC). No responsibility is taken or implied by TEC for the structural integrity of the structure below the trusses or the affects of TEC’s product on the structure as a whole. The truss installer shall follow all BCSI recommendations, construction document specifications as well as any site specific requirements to ensure safe and proper installation. No loading shall be applied to trusses until properly and fully installed, including all sheathing, hangers, wall anchors, lateral web bracing (as shown on individual shop drawings), and permanent bracing (as required by the construction documents). Installation contractor shall refer to the individual truss shop drawings for all structural requirements of trusses,including but not limited to bearing locations and requirements, ply to ply nailing, lateral web bracing, and truss spacing. Truss Engineering Corporation strictly adheres to the ‘Standard Responsibilities in the Design of Metal Plate Connected Wood Trusses’ as defined by TPI Chapter 2 (available upon request) regardless of any job specific specifications unless clearly defined otherwise in writing by TEC.This placement plan is Truss Engineering Corporation’sINTERPRETATION of plans and drawings as supplied to us. The building owner/owner’s agent is solely responsible for verifying all dimensions, geometry, loads and load requirements for accuracy and full compliance to construction documents and shall be responsible for notifying TEC immediately of any discrepancies. The building owner/owner’s agent is responsible for coordinating all construction details between trades. Truss Engineering Corporation isNOT responsible for field verification of dimensions or special conditions. No trusses supplied by Truss Engineering Corporation may be cut, drilled, or altered in any way without first contacting TEC and receiving engineering documents allowing such.Quote Number: Q1211232 Drawn By: Brian Tetreault Job Name:Jobsite: ROSEMUND 24 NUTTING AVE. NORTHAMPTONMA Va l l e y L i n e s : 1 2 . 2 5 ( f t ) / H o r i z on t a l O v e r h a n g L i n e s : 1 5 6 . 4 6 ( f t ) / Ra k e d O v e r h a n g L i n e s : 6 6 . 6 4 ( f t ) Th e f o l l o w i n g i n f o r m a t i o n i s a pp r o x i m a t e a n d N O T g u a r a n t e e d : Ro o f S h e a t h i n g A r e a : 1 6 6 2 . 6 9 ( f t ² ) / R i d g e L i n e s : 3 5 . 1 7 (f t ) / H i p L i ne s : 6 6 . 7 5 ( f t ) Job 28851 Truss 01 Truss Type Jack-Closed Truss Qty 6 Ply 1 24 NUTTING AVE. NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jan 22 06:51:53 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:4GZrvWKYaxh?kY6tCyFvGlzuT95-CBv1S4bAqbPxjRHtUaAfIxpX3EhT35UOA2Umjszsuaa Scale = 1:23.3 W1 T1 W2 B1 1 2 3 5 4 3x4 4x4 3x6 3x4 6-0-15 6-0-15 -1-0-0 1-0-0 6-0-15 6-0-15 1-0-0 4-0-8 6.00 12 Plate Offsets (X,Y): [2:0-2-0,0-1-12] LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL BCDL 38.5 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.590.270.00 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.04-0.110.00 (loc) 4-54-54 l/defl >999>608n/a L/d 240180n/a PLATES MT20 Weight: 21 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF No.2 *Except* W2: 2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)5 =381/0-5-8 (min. 0-1-8)4 =274/MechanicalMax Horz5 =141(LC 9)Max Uplift 5 =-69(LC 9) 4 =-97(LC 9) Max Grav 5 =461(LC 2)4 =328(LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-5=-424/172 TOP CHORD2-5=-424/172 NOTES (13) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.60 plate grip DOL=1.602) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 38.5 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.8) All bearings are assumed to be SPF No.2 . 9) Refer to girder(s) for truss to truss connections.10) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 69 lb uplift at joint 5 and 97 lb uplift at joint 4. 11) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 13) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job 28851 Truss 02 Truss Type Jack-Closed Truss Qty 6 Ply 1 24 NUTTING AVE. NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jan 22 06:51:57 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:4GZrvWKYaxh?kY6tCyFvGlzuT95-4y9XIRehuqwNC2bejQFbSnzIxr5v?vU_5gSzsdzsuaW Scale = 1:17.1 W1 T1 W2 B1 1 2 3 5 4 2x4 2x4 3x4 1.5x4 4-0-15 4-0-15 -1-0-0 1-0-0 4-0-15 4-0-15 1-0-0 3-0-8 6.00 12 LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLLBCDL 38.5 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.22 0.110.00 DEFL Vert(LL) Vert(TL)Horz(TL) in -0.01 -0.020.00 (loc) 4-5 4-54 l/defl >999 >999n/a L/d 240 180n/a PLATES MT20 Weight: 15 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF No.2 *Except* W2: 2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 4-0-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)5 =288/0-5-8 (min. 0-1-8)4 =172/MechanicalMax Horz5 =103(LC 9)Max Uplift5 =-60(LC 9) 4 =-66(LC 9) Max Grav 5 =349(LC 2) 4 =205(LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-5=-321/136 TOP CHORD2-5=-321/136 NOTES (13) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.602) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 38.5 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members.8) All bearings are assumed to be SPF No.2 . 9) Refer to girder(s) for truss to truss connections.10) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 60 lb uplift at joint 5 and 66 lb uplift at joint 4. 11) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 13) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job 28851 Truss 03 Truss Type Jack-Open Truss Qty 6 Ply 1 24 NUTTING AVE. NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jan 22 06:52:00 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:4GZrvWKYaxh?kY6tCyFvGlzuT95-VXqgwTgZBlIy3WJDOYoI4Qbrg28cCGDQnegdSyzsuaT Scale = 1:12.4 W1 T1 B1 1 2 5 3 4 1.5x4 2x4 2-0-15 2-0-15 -1-0-0 1-0-0 2-0-15 2-0-15 1-0-0 2-0-8 1-7-13 6.00 12 LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLLBCDL 38.5 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.12 0.040.00 DEFL Vert(LL) Vert(TL)Horz(TL) in 0.00 -0.00-0.00 (loc) 5 4-53 l/defl >999 >999n/a L/d 240 180n/a PLATES MT20 Weight: 7 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF No.2BRACING TOP CHORD Structural wood sheathing directly applied or 2-0-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)5 =208/0-5-8 (min. 0-1-8)3 =50/Mechanical4 =14/MechanicalMax Horz5 =66(LC 9)Max Uplift5 =-54(LC 9) 3 =-32(LC 9) 4 =-2(LC 9) Max Grav 5 =255(LC 2)3 =62(LC 2)4 =34(LC 5) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES (13) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever leftand right exposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.60 plate grip DOL=1.602) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 38.5 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.8) All bearings are assumed to be SPF No.2 . 9) Refer to girder(s) for truss to truss connections.10) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 54 lb uplift at joint 5, 32 lb uplift at joint 3 and 2 lb uplift at joint 4.11) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 13) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job 28851 Truss 04 Truss Type Jack-Closed Truss Qty 6 Ply 1 24 NUTTING AVE. NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jan 22 06:52:06 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:4GZrvWKYaxh?kY6tCyFvGlzuT95-KhBxBWlKnb25nRnNkpviKhrpAT44cykJAZ7ygczsuaN Scale = 1:28.3 W1 T1 W3 B1 W2 1 2 3 4 6 5 7 8 4x4 4x6 3x4 4x4 1.5x4 8-2-0 8-2-0 -1-0-0 1-0-0 4-1-0 4-1-0 8-2-0 4-1-0 1-0-0 5-1-0 6.00 12 Plate Offsets (X,Y): [2:0-3-0,Edge] LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL BCDL 38.5 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.380.490.19 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.14-0.340.00 (loc) 5-65-65 l/defl >673>278n/a L/d 240180n/a PLATES MT20 Weight: 32 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W1: 2 X 4 SPF No.2BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)6 =480/0-5-8 (min. 0-1-8)5 =378/MechanicalMax Horz6 =169(LC 9)Max Uplift 6 =-82(LC 9) 5 =-101(LC 9) Max Grav 6 =580(LC 2)5 =453(LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-6=-492/153, 2-7=-470/35, 3-7=-322/48 TOP CHORD2-6=-492/153, 2-7=-470/35, 3-7=-322/48 BOT CHORD 5-6=-180/335 WEBS 3-5=-379/216 NOTES (13)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0,Interior(1) 2-0-0 to 3-9-5, Exterior(2) 3-9-5 to 8-0-4 zone; cantilever left and rightexposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.60 plate grip DOL=1.602) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 38.5 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.8) All bearings are assumed to be SPF No.2 . 9) Refer to girder(s) for truss to truss connections.10) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 82 lb uplift at joint 6 and 101 lb uplift at joint 5.11) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 13) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard Job 28851 Truss 04G Truss Type JACK-CLOSED TRUSS Qty 1 Ply 1 24 NUTTING AVE. NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jan 22 06:52:17 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:4GZrvWKYaxh?kY6tCyFvGlzuT95-VoM5UHtEBzRXb76UudcHG?of_vl7hmQwinI1ZTzsuaC Scale = 1:30.3 T1 W3 B1 W1 W2 HW1 1 2 3 4 5 7 6 12 13 14 1.5x4 5x12 4x4 3x8 4x6 4x9 HUS26 HUS26 HUS26 4-1-0 4-1-0 8-2-0 4-1-0 -1-0-0 1-0-0 4-1-0 4-1-0 8-2-0 4-1-0 1-0-0 5-1-0 6.00 12 Plate Offsets (X,Y): [2:0-7-13,0-1-13], [7:0-4-12,0-1-8] LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL BCDL 38.5 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15NOIRC2009/TPI2007 CSI TCBCWB(Matrix-M) 0.470.780.77 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.06-0.090.02 (loc) 6-76-76 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 43 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 6 SPF 1650F 1.5EWEBS2 X 4 SPF Stud SLIDER Left 2 X 6 SPF 1650F 1.5E 2-6-0 BRACING TOP CHORD Structural wood sheathing directly applied or 3-10-9 oc purlins, except end verticals.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 4-6 REACTIONS (lb/size)2 =1464/0-5-8 (min. 0-2-13)6 =1525/Mechanical Max Horz 2 =168(LC 8) Max Uplift 2 =-255(LC 8)6 =-300(LC 8)Max Grav2 =1795(LC 13)6 =1930(LC 13) Max Grav2 =1795(LC 13) 6 =1930(LC 13) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1209/122, 3-4=-2095/257BOT CHORD2-13=-320/1838, 7-13=-320/1838, 7-14=-320/1838, 6-14=-320/1838WEBS4-7=-225/1789, 4-6=-2215/386 NOTES (17)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 38.5 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.8) All bearings are assumed to be SPF No.2 . 9) Refer to girder(s) for truss to truss connections.10) Provide metal plate or equivalent at bearing(s) 5 to support reaction shown.11) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 255 lb uplift at joint 8 and 300 lb uplift at joint 6. 12) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 14) Use Simpson Strong-Tie HUS26 (14-10d Girder, 4-10d Truss, Single Ply Girder) orequivalent spaced at 2-0-0 oc max. starting at 2-2-12 from the left end to 6-2-12 toconnect truss(es) T2A (1 ply 2 X 4 SPF) to front face of bottom chord. 15) Fill all nail holes where hanger is in contact with lumber.16) In the LOAD CASE(S) section, loads applied to the face of the truss are noted asfront (F) or back (B).17) All Plates 20 Gauge Unless Noted LOAD CASE(S) StandardContinued on page 2 Job 28851 Truss 04G Truss Type JACK-CLOSED TRUSS Qty 1 Ply 1 24 NUTTING AVE. NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jan 22 06:52:17 2013 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:4GZrvWKYaxh?kY6tCyFvGlzuT95-VoM5UHtEBzRXb76UudcHG?of_vl7hmQwinI1ZTzsuaC LOAD CASE(S)Standard1) Snow: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-5=-78, 6-8=-20Concentrated Loads (lb) Vert: 7=-674(F) 13=-669(F) 14=-783(F) Job 28851 Truss CJ1 Truss Type DIAGONAL HIP GIRDER Qty 3 Ply 1 24 NUTTING AVE. NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jan 22 06:52:53 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:4GZrvWKYaxh?kY6tCyFvGlzuT95-SjXi2bJpi1zQwftP?BFjkbIkUQ1U77wDzN0xpNzsuZe Scale = 1:30.4 T1 W3 B1 W1 W2 HW11 2 3 4 5 7 6 14 15 16 17 1.5x4 8x9 4x4 2x4 4x6 4x4 Nailed Nailed SNP3 SNP3 Nailed Nailed SNP3 SNP3 5-8-0 5-8-0 11-5-1 5-9-1 -1-5-0 1-5-0 5-8-0 5-8-0 11-5-1 5-9-1 1-0-0 5-0-7 4.24 12 Plate Offsets (X,Y): [2:0-6-1,0-0-5] LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL BCDL 38.5 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15NOIRC2009/TPI2007 CSI TCBCWB(Matrix-M) 0.810.840.48 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.12-0.21-0.03 (loc) 6-76-72 l/defl >999>637n/a L/d 240180n/a PLATES MT20 Weight: 55 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5EBOT CHORD 2 X 6 SPF 1650F 1.5EWEBS2 X 4 SPF Stud SLIDER Left 2 X 6 SPF 1650F 1.5E 2-6-0 BRACING TOP CHORD Structural wood sheathing directly applied or 5-0-6 oc purlins, except end verticals.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 4-6 REACTIONS (lb/size)2 =914/0-7-6 (min. 0-1-13)6 =1046/Mechanical Max Horz 2 =167(LC 6) Max Uplift 2 =-296(LC 6)6 =-351(LC 6)Max Grav2 =1149(LC 13)6 =1391(LC 13) Max Grav2 =1149(LC 13) 6 =1391(LC 13) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-2=-473/27, 2-3=-359/18, 3-14=-1617/381, 4-14=-1541/389, 5-6=-320/58BOT CHORD2-8=-453/1487, 2-16=-453/1487, 7-16=-453/1487, 7-17=-453/1487, 6-17=-453/1487WEBS4-7=-219/753, 4-6=-1641/499 NOTES (19) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 38.5 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.8) All bearings are assumed to be SPF No.2 . 9) Refer to girder(s) for truss to truss connections.10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 296 lb uplift at joint 10 and 351 lb uplift at joint 6. 11) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 13) Use USP SNP3 (With 8d x 1-1/2" nails into Girder & 8d x 1-1/2" nails into Truss) orequivalent spaced at 2-9-15 oc max. starting at 5-10-4 from the left end to 8-8-3 toconnect truss(es) 02 (1 ply 2 X 4 SPF) to front face of bottom chord. 14) Use USP SNP3 (With 8d x 1-1/2" nails into Girder & 8d x 1-1/2" nails into Truss) orequivalent spaced at 2-9-15 oc max. starting at 5-10-4 from the left end to 8-8-3 toconnect truss(es) 02 (1 ply 2 X 4 SPF) to back face of bottom chord. Continued on page 2 Job 28851 Truss CJ1 Truss Type DIAGONAL HIP GIRDER Qty 3 Ply 1 24 NUTTING AVE. NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jan 22 06:52:53 2013 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:4GZrvWKYaxh?kY6tCyFvGlzuT95-SjXi2bJpi1zQwftP?BFjkbIkUQ1U77wDzN0xpNzsuZe NOTES (19) 15) WARNING: The following hangers are manually applied but fail due to geometric considerations: SNP3 on front face at 5-10-4 from the left end, SNP3 on front face at 8-8-3 from the left end, SNP3 on back face at 5-10-4 from the left end, SNP3 on back face at8-8-3 from the left end.16) "Nailed" indicates 3-10d or 2-12d common wire toe-nails. For more details refer toMiTek's ST-TOENAIL Detail. 17) SNP3: A minimum of (6) 8d x 1-1/2" nails are required into each member. All nailing isrequired in face of supported chords. For sloped applications, flanges may protrude aboveor below truss chords. Bending of extended flanges is permitted. 18) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front(F) or back (B). 19) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard 1) Snow: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-5=-78, 6-8=-20Concentrated Loads (lb)Vert: 7=-303(F=-152, B=-152) 14=56(F=28, B=28) 16=8(F=4, B=4) 17=-508(F=-254,B=-254) Job 28851 Truss G1 Truss Type HIP TRUSS Qty 1 Ply 2 24 NUTTING AVE. NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jan 22 06:53:34 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:4GZrvWKYaxh?kY6tCyFvGlzuT95-lcWCfcpX2d8cLyVHuIULuEUiMx2yDi9GPGScmVzsuZ? Scale = 1:34.7 0-1-11 0-1-11 T1 T2 T1 B1 W1 W2 W3 W4 W3 W2 W1HW1 HW1 B2 1 2 3 4 5 6 7 8 9 10 11 14 13 12 23 24 25 26 27 28 6x6 6x6 6x9 4x9 6x6 1.5x4 7x8 1.5x4 6x6 1.5x4 6x9 4x9 THJA26 LUS26 LUS26 LUS26 THJA26 8-2-0 8-2-0 12-2-0 4-0-0 16-2-0 4-0-0 24-4-0 8-2-0 -1-0-0 1-0-0 4-3-0 4-3-0 8-2-0 3-11-0 12-2-0 4-0-0 16-2-0 4-0-0 20-1-0 3-11-0 24-4-0 4-3-0 25-4-0 1-0-0 1-0-0 4-11-5 5-1-0 1-0-0 4-11-5 6.00 12 Plate Offsets (X,Y): [2:0-6-1,0-1-5], [10:0-6-1,0-1-5], [12:0-3-0,0-4-4], [13:0-2-8,0-5-4], [14:0-3-0,0-4-4] LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL BCDL 38.5 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15NOIRC2009/TPI2007 CSI TCBCWB(Matrix-M) 0.930.720.34 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.19-0.310.10 (loc) 12-1312-1310 l/defl >999>944n/a L/d 240180n/a PLATES MT20 Weight: 246 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5EBOT CHORD 2 X 6 SPF 1650F 1.5EWEBS2 X 4 SPF Stud SLIDER Left 2 X 6 SPF 1650F 1.5E 2-6-0, Right 2 X 6 SPF 1650F 1.5E 2-6-0 BRACING TOP CHORDStructural wood sheathing directly applied or 3-3-12 oc purlins, except 2-0-0 oc purlins (5-7-7 max.): 5-7.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)2 =3290/0-5-8 (min. 0-3-6)10 =3285/0-5-8 (min. 0-3-6) Max Horz 2 =-51(LC 9) Max Uplift 2 =-842(LC 8)10 =-840(LC 9)Max Grav2 =4307(LC 27)10 =4301(LC 27) Max Grav2 =4307(LC 27) 10 =4301(LC 27) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1734/245, 3-4=-6764/1393, 4-23=-6687/1415, 5-23=-6586/1426, 5-24=-6862/1471, 6-24=-6866/1471, 6-25=-6896/1475, 7-25=-6892/1475, 7-26=-6582/1425, 8-26=-6683/1414, 8-9=-6758/1391, 9-10=-1711/240BOT CHORD2-14=-1166/5788, 14-27=-1220/5915, 13-27=-1220/5915, 13-28=-1180/5911, 12-28=-1180/5911, 10-12=-1114/5782WEBS4-14=-170/691, 5-14=-330/1539, 5-13=-343/1486, 6-13=-824/156, 7-13=-341/1468, 7-12=-342/1590, 8-12=-171/695 NOTES (20) 1) 2-ply truss to be connected together with 10d (0.148"x3") nails as follows: Top chords connected as follows: 2 X 4 - 1 row at 0-7-0 oc.Bottom chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc.Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been providedto distribute only loads noted as (F) or (B), unless otherwise indicated.3) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; LumberDOL=1.60 plate grip DOL=1.604) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-05) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 38.5 psf on overhangs non-concurrent with other live loads. 7) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 8) Provide adequate drainage to prevent water ponding.9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.10) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.11) All bearings are assumed to be SPF No.2 . 12) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 842 lb uplift at joint 15 and 840 lb uplift at joint 19. 13) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.Continued on page 2 Job 28851 Truss G1 Truss Type HIP TRUSS Qty 1 Ply 2 24 NUTTING AVE. NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jan 22 06:53:34 2013 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:4GZrvWKYaxh?kY6tCyFvGlzuT95-lcWCfcpX2d8cLyVHuIULuEUiMx2yDi9GPGScmVzsuZ? NOTES (20) 14) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 15) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to trussTC w/ 2-10d nails.16) Use Simpson Strong-Tie THJA26 (THJA26 on 2 ply, Right Hand Hip) or equivalent at8-2-6 from the left end to connect truss(es) 04 (1 ply 2 X 4 SPF), CJ1 (1 ply 2 X 6 SPF) toback face of bottom chord. 17) Use Simpson Strong-Tie LUS26 (4-10d Girder, 3-10d Truss, Single Ply Girder) orequivalent spaced at 1-11-4 oc max. starting at 10-2-12 from the left end to 14-1-4 toconnect truss(es) 04 (1 ply 2 X 4 SPF) to back face of bottom chord. 18) Use Simpson Strong-Tie THJA26 (THJA26 on 2 ply, Left Hand Hip) or equivalent at 16-1-10 from the left end to connect truss(es) 04 (1 ply 2 X 4 SPF), CJ1 (1 ply 2 X 6 SPF) to back face of bottom chord. 19) Fill all nail holes where hanger is in contact with lumber. 20) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard1) Snow: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-5=-78, 5-7=-78, 7-11=-78, 15-19=-20Concentrated Loads (lb)Vert: 14=-1483(B) 13=-358(B) 12=-1483(B) 27=-358(B) 28=-358(B) Job 28851 Truss G1A Truss Type HIP TRUSS Qty 1 Ply 2 24 NUTTING AVE. NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jan 22 06:53:27 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:4GZrvWKYaxh?kY6tCyFvGlzuT95-SGbZBDk8iUFc?tTx_Ksi6miWv7de4TQEogFk0PzsuZ6 Scale = 1:34.7 0-1-11 0-1-11 T1 T2 T1 B1 W1 W2 W3 W4 W3 W2 W1HW1 HW1 B2 1 2 3 4 5 6 7 8 9 10 11 14 13 12 23 24 25 26 27 6x6 6x6 6x9 4x9 7x8 1.5x4 8x9 1.5x4 3x4 1.5x4 5x9 4x6 THJA26 HUS26 8-2-0 8-2-0 12-2-0 4-0-0 16-2-0 4-0-0 24-4-0 8-2-0 -1-0-0 1-0-0 4-3-0 4-3-0 8-2-0 3-11-0 12-2-0 4-0-0 16-2-0 4-0-0 20-1-0 3-11-0 24-4-0 4-3-0 25-4-0 1-0-0 1-0-0 4-11-5 5-1-0 1-0-0 4-11-5 6.00 12 Plate Offsets (X,Y): [2:0-6-9,0-0-9], [10:0-6-1,0-1-5], [13:0-3-8,0-4-12], [14:0-3-8,0-4-12] LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL BCDL 38.5 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15NOIRC2009/TPI2007 CSI TCBCWB(Matrix-M) 0.940.890.60 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.20-0.320.08 (loc) 13-1413-1410 l/defl >999>923n/a L/d 240180n/a PLATES MT20 Weight: 246 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5EBOT CHORD 2 X 6 SPF 1650F 1.5EWEBS2 X 4 SPF Stud SLIDER Left 2 X 6 SPF 1650F 1.5E 2-6-0, Right 2 X 6 SPF 1650F 1.5E 2-6-0 BRACING TOP CHORDStructural wood sheathing directly applied or 3-2-2 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 5-7.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)2 =3189/0-5-8 (min. 0-3-5)10 =2396/0-5-8 (min. 0-2-8) Max Horz 2 =-51(LC 9) Max Uplift 2 =-702(LC 8)10 =-485(LC 9)Max Grav2 =4190(LC 27)10 =3226(LC 27) Max Grav2 =4190(LC 27) 10 =3226(LC 27) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1475/156, 3-4=-6611/1152, 4-23=-6543/1162, 5-23=-6442/1172, 5-24=-5916/1010, 6-24=-5920/1010, 6-25=-5950/1013, 7-25=-5945/1014, 7-26=-4509/743, 8-26=-4610/734, 8-9=-4828/755, 9-10=-1344/107BOT CHORD2-14=-959/5644, 14-27=-984/5759, 13-27=-984/5759, 12-13=-574/4084, 10-12=-572/4137WEBS4-14=-142/711, 5-14=-492/2417, 5-13=-275/248, 6-13=-809/150, 7-13=-556/2783, 7-12=-509/183, 8-12=-78/404 NOTES (19) 1) 2-ply truss to be connected together with 10d (0.148"x3") nails as follows: Top chords connected as follows: 2 X 4 - 1 row at 0-7-0 oc.Bottom chords connected as follows: 2 X 6 - 2 rows at 0-5-0 oc.Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been providedto distribute only loads noted as (F) or (B), unless otherwise indicated.3) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; LumberDOL=1.60 plate grip DOL=1.604) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-05) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 38.5 psf on overhangs non-concurrent with other live loads. 7) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 8) Provide adequate drainage to prevent water ponding.9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.10) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.11) All bearings are assumed to be SPF No.2 . 12) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 702 lb uplift at joint 15 and 485 lb uplift at joint 19. 13) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.Continued on page 2 Job 28851 Truss G1A Truss Type HIP TRUSS Qty 1 Ply 2 24 NUTTING AVE. NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jan 22 06:53:27 2013 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:4GZrvWKYaxh?kY6tCyFvGlzuT95-SGbZBDk8iUFc?tTx_Ksi6miWv7de4TQEogFk0PzsuZ6 NOTES (19) 14) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 15) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to trussTC w/ 2-10d nails.16) Use Simpson Strong-Tie THJA26 (THJA26 on 2 ply, Left Hand Hip) or equivalent at8-2-6 from the left end to connect truss(es) 04 (1 ply 2 X 4 SPF), CJ1 (1 ply 2 X 6 SPF) tofront face of bottom chord. 17) Use Simpson Strong-Tie HUS26 (14-10d Girder, 6-10d Truss, Single Ply Girder) orequivalent at 9-11-4 from the left end to connect truss(es) 04G (1 ply 2 X 6 SPF) to frontface of bottom chord, skewed 0.0 deg.to the right, sloping 0.0 deg. down. 18) Fill all nail holes where hanger is in contact with lumber. 19) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard 1) Snow: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-5=-78, 5-7=-78, 7-11=-78, 15-19=-20Concentrated Loads (lb)Vert: 14=-1483(F) 27=-1569(F) Job 28851 Truss H1 Truss Type Hip Truss Qty 2 Ply 1 24 NUTTING AVE. NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jan 22 06:53:55 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:4GZrvWKYaxh?kY6tCyFvGlzuT95-dfH83o3i64ndMBcJdCMGFgsN3PFoe4OLE11D_nzsuYg Scale = 1:36.8 0-1-11 0-1-11 T1 T2 T1 B1 W3 W4 W5 W6 W5 W4 W3W1 W2 W1 W2B2 1 2 3 4 5 6 7 8 15 14 13 12 11 10 9 1617 18 19 20 21 2223 24 6x6 4x6 3x4 3x6 3x4 6x6 3x4 3x8 3x4 6x6 4x9 3x4 4x9 5-0-0 5-0-0 10-2-0 5-2-0 14-2-0 4-0-0 19-4-0 5-2-0 24-4-0 5-0-0 -1-0-0 1-0-0 5-0-0 5-0-0 10-2-0 5-2-0 14-2-0 4-0-0 19-4-0 5-2-0 24-4-0 5-0-0 25-4-0 1-0-0 1-0-0 5-11-5 6-1-0 1-0-0 5-11-5 6.00 12 LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLLBCDL 38.5 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.61 0.600.85 DEFL Vert(LL) Vert(TL)Horz(TL) in -0.11 -0.180.06 (loc) 13-14 13-149 l/defl >999 >999n/a L/d 240 180n/a PLATES MT20 Weight: 113 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5EBOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W1: 2 X 6 SPF 1650F 1.5EBRACING TOP CHORD Structural wood sheathing directly applied or 3-10-7 oc purlins, except end verticals, and 2-0-0 oc purlins (5-2-12 max.): 4-5. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)15 =1285/0-5-8 (min. 0-3-4)9 =1280/0-5-8 (min. 0-3-4)Max Horz15 =-54(LC 7)Max Uplift 15 =-208(LC 9) 9 =-208(LC 10) Max Grav 15 =2074(LC 28)9 =2074(LC 28) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-16=-2688/323, 16-17=-2539/329, 3-17=-2388/339, TOP CHORD2-16=-2688/323, 16-17=-2539/329, 3-17=-2388/339, 3-18=-2158/330, 18-19=-1961/339, 4-19=-1959/348, 4-5=-1753/352, 5-20=-1960/348, 20-21=-1962/339, 6-21=-2159/330, 6-22=-2387/339, 22-23=-2538/329, 7-23=-2688/323, 2-15=-2015/320, 7-9=-2015/320 BOT CHORD 14-15=-79/309, 13-14=-212/2259, 13-24=-129/1752, 12-24=-129/1752, 11-12=-212/2259, 10-11=-212/2259, 9-10=-28/309WEBS3-13=-589/115, 4-13=-17/414, 5-12=-8/414, 6-12=-587/115, 2-14=-217/1978, 7-10=-217/1977 NOTES (14)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 5-11-1, Exterior(2) 5-11-1 to 18-4-15, Interior(1) 18-4-15 to 22-4-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.602) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-03) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 38.5 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 6) Provide adequate drainage to prevent water ponding.7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.8) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.9) All bearings are assumed to be SPF No.2 . 10) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 208 lb uplift at joint 15 and 208 lb uplift at joint 9. 11) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 13) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened totruss TC w/ 2-10d nails.14) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job 28851 Truss T1 Truss Type Common Truss Qty 6 Ply 1 24 NUTTING AVE. NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jan 22 06:54:00 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:4GZrvWKYaxh?kY6tCyFvGlzuT95-_c416V7qwdPwSyUHQlyRxjZCuQy0JQ35NJl_g?zsuYb Scale = 1:42.4 T1 T1 B1 W4 W3 W4 W3 W1 W2 W1 W2 B2 1 2 3 4 5 6 7 11 10 9 8 12 13 14 15 16 17 18 19 5x6 6x6 4x4 3x4 4x4 4x6 4x6 4x6 4x6 8-6-0 8-6-0 15-10-0 7-4-0 24-4-0 8-6-0 -1-0-0 1-0-0 6-3-0 6-3-0 12-2-0 5-11-0 18-1-0 5-11-0 24-4-0 6-3-0 25-4-0 1-0-0 1-0-0 7-1-0 1-0-0 6.00 12 Plate Offsets (X,Y): [4:0-3-8,0-2-8], [9:0-3-0,Edge] LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL BCDL 38.5 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.730.600.50 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.17-0.310.07 (loc) 9-1010-118 l/defl >999>928n/a L/d 240180n/a PLATES MT20 Weight: 105 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5EBOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W1: 2 X 6 SPF 1650F 1.5EBRACING TOP CHORD Structural wood sheathing directly applied or 3-7-9 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 3-11, 5-8 REACTIONS (lb/size)11 =1308/0-5-8 (min. 0-2-6)8 =1308/0-5-8 (min. 0-2-6)Max Horz 11 =66(LC 8) Max Uplift 11 =-210(LC 9) 8 =-210(LC 10)Max Grav11 =1516(LC 2)8 =1516(LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 2-12=-592/145, 3-12=-360/165, 3-13=-1814/303, 13-14=-1684/312, 4-14=-1675/323, 4-15=-1675/323, 15-16=-1684/312, 5-16=-1814/303, 5-17=-360/165, 6-17=-592/145, 2-11=-618/214, 6-8=-618/214 BOT CHORD10-11=-169/1696, 10-18=-57/1239, 18-19=-57/1239, 9-19=-57/1239, 8-9=-169/1696WEBS4-9=-75/646, 5-9=-484/173, 4-10=-75/646, 3-10=-484/172, 3-11=-1528/191, 5-8=-1528/191 NOTES (12)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-2-0, Exterior(2) 9-2-0 to 12-2-0, Interior(1) 15-2-0 to 22-4-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.602) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 38.5 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.8) All bearings are assumed to be SPF No.2 . 9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 210 lb uplift at joint 11 and 210 lb uplift at joint 8. 10) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 12) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job 28851 Truss T2GE Truss Type Common Truss Qty 1 Ply 1 24 NUTTING AVE. NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jan 22 06:54:58 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:4GZrvWKYaxh?kY6tCyFvGlzuT95-HmazHKqDGRjhQswQpx?1IyzGlouQvlwdjKo2iezsuXh Scale = 1:25.3 W1 T1 T1 W1 B1 ST4 ST3 ST2 ST1 ST3 ST2 ST11 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 21 22 23 24 25 26 27 28 2x4 4x4 2x4 14-4-0 14-4-0 -1-0-0 1-0-0 7-2-0 7-2-0 14-4-0 7-2-0 15-4-0 1-0-0 1-0-0 4-7-0 1-0-0 6.00 12 LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLLBCDL 38.5 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.12 0.030.09 DEFL Vert(LL) Vert(TL)Horz(TL) in -0.01 -0.000.00 (loc) 11 1112 l/defl n/r n/rn/a L/d 120 90n/a PLATES MT20 Weight: 57 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF No.2OTHERS2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS All bearings 14-4-0.(lb) - Max Horz20= -52(LC 10)Max UpliftAll uplift 100 lb or less at joint(s) 20, 12, 17, 18, 19, 15, 14, 13Max Grav All reactions 250 lb or less at joint(s) 20, 12, 19, 13 except 16=252(LC 2), 17=295(LC 14), 18=258(LC 14), 15=295(LC 15), 14=258(LC 15) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.WEBS5-17=-255/142, 7-15=-256/142 NOTES (17) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Corner(3) -1-0-0 to 2-0-0,Exterior(2) 2-0-0 to 4-2-0, Corner(3) 4-2-0 to 7-2-0, Exterior(2) 10-2-0 to 12-4-0 zone;cantilever left and right exposed ;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.602) Truss designed for wind loads in the plane of the truss only. For studs exposed towind (normal to the face), see Standard Industry Gable End Details as applicable, orconsult qualified building designer as per ANSI/TPI 1.3) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 38.5 psf on overhangs non-concurrent with other live loads. 6) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.7) All plates are 1.5x4 MT20 unless otherwise indicated.8) Gable requires continuous bottom chord bearing. 9) Truss to be fully sheathed from one face or securely braced against lateral movement(i.e. diagonal web).10) Gable studs spaced at 2-0-0 oc.11) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 12) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members.13) All bearings are assumed to be SPF No.2 . 14) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) 20, 12, 17, 18, 19, 15, 14, 13.15) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.16) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 17) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard Job 28851 Truss T2 Truss Type COMMON TRUSS Qty 1 Ply 1 24 NUTTING AVE. NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jan 22 06:54:14 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:4GZrvWKYaxh?kY6tCyFvGlzuT95-aJwK2HIcdwAx86ZzEiCjWg8hF3kbblv8cU8j9BzsuYN Scale = 1:28.0 T1 T2 B1 W4 W3W3 W1 W2 W1 W2 1 2 3 4 5 6 9 8 7 10 11 12 13 14 4x4 1.5x4 3x8 4x4 4x4 1.5x4 3x4 3x4 7-2-0 7-2-0 14-4-0 7-2-0 -1-0-0 1-0-0 4-0-0 4-0-0 7-2-0 3-2-0 10-4-0 3-2-0 14-4-0 4-0-0 1-0-0 4-7-0 1-0-0 6.00 12 LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLLBCDL 38.5 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-2-0 1.15 1.15NOIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.35 0.580.54 DEFL Vert(LL) Vert(TL)Horz(TL) in -0.07 -0.180.02 (loc) 7-8 7-87 l/defl >999 >922n/a L/d 240 180n/a PLATES MT20 Weight: 61 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W1: 2 X 4 SPF No.2BRACING TOP CHORD 2-0-0 oc purlins (5-10-6 max.), except end verticals (Switched from sheeted: Spacing > 2-0-0). BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.JOINTS1 Brace at Jt(s): 4, 6, 2 REACTIONS (lb/size)9 =844/0-5-8 (min. 0-1-9)7 =740/0-5-8 (min. 0-1-8)Max Horz 9 =70(LC 9) Max Uplift 9 =-171(LC 9) 7 =-114(LC 10)Max Grav9 =1015(LC 2)7 =885(LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD3-11=-934/208, 11-12=-920/216, 4-12=-835/220, 4-13=-837/223, 5-13=-937/212, 2-9=-301/181 BOT CHORD 8-9=-170/930, 7-8=-192/949 WEBS 4-8=-95/487, 5-8=-321/167, 3-8=-286/147, 3-9=-1138/168, 5-7=-1161/236 NOTES (13)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0,Interior(1) 2-0-0 to 3-10-8, Exterior(2) 3-10-8 to 7-2-0, Interior(1) 10-5-8 to 11-2-4 zone;cantilever left and right exposed ;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 38.5 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members.8) All bearings are assumed to be SPF No.2 . 9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 171 lb uplift at joint 9 and 114 lb uplift at joint 7.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 13) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard Job 28851 Truss T2A Truss Type Special Truss Qty 1 Ply 1 24 NUTTING AVE. NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jan 22 06:54:39 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:4GZrvWKYaxh?kY6tCyFvGlzuT95-L6xnIrbIkcKOeyznCS9a1yhpo8Iuy3uqLthYYEzsuY_ Scale = 1:28.0 0-1-11T1 T2 T3 W7 B1 W3 W4 W5 W6W1 W2 1 2 3 4 5 6 9 8 7 10 11 12 13 14 15 4x4 6x6 1.5x4 3x6 3x8 4x4 1.5x4 3x4 7-2-0 7-2-0 12-2-0 5-0-0 14-4-0 2-2-0 -1-0-0 1-0-0 4-0-0 4-0-0 7-2-0 3-2-0 12-2-0 5-0-0 14-4-0 2-2-0 1-0-01-11-5 4-7-0 1-11-5 6.00 12 LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLLBCDL 38.5 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.94 0.480.49 DEFL Vert(LL) Vert(TL)Horz(TL) in -0.06 -0.170.02 (loc) 7-8 7-87 l/defl >999 >999n/a L/d 240 180n/a PLATES MT20 Weight: 60 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2 *Except* T2: 2 X 4 SPF 1650F 1.5EBOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W1: 2 X 4 SPF No.2BRACING TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc purlins (10-0-0 max.): 5-6.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.JOINTS1 Brace at Jt(s): 6 REACTIONS (lb/size)7 =683/Mechanical9 =779/0-5-8 (min. 0-1-8) Max Horz 9 =88(LC 9) Max Uplift 7 =-108(LC 10)9 =-156(LC 9)Max Grav7 =826(LC 28)9 =937(LC 2) Max Grav7 =826(LC 28)9 =937(LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-11=-863/176, 11-12=-850/184, 4-12=-771/187, 4-13=-720/165, 13-14=-779/158, 14-15=-808/155, 5-15=-915/154, 2-9=-278/167BOT CHORD8-9=-194/859, 7-8=-172/859WEBS3-8=-264/136, 4-8=-21/336, 5-7=-1126/226, 3-9=-1051/140 NOTES (15)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 3-10-8, Exterior(2) 3-10-8 to 7-2-0, Interior(1) 10-2-0 to 12-2-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-03) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 timesflat roof load of 38.5 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 6) Provide adequate drainage to prevent water ponding.7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.8) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.9) All bearings are assumed to be SPF No.2 . 10) Refer to girder(s) for truss to truss connections.11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 108 lb uplift at joint 7 and 156 lb uplift at joint 9. 12) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 14) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened totruss TC w/ 2-10d nails.15) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job 28851 Truss T2B Truss Type Special Truss Qty 1 Ply 1 24 NUTTING AVE. NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jan 22 06:54:43 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:4GZrvWKYaxh?kY6tCyFvGlzuT95-DuAI8Cepoqqp6ZHYRHDWBorZVlfpusVQGVflg?zsuXw Scale = 1:28.0 0-1-11 T1 T2 T3 W7 B1 W3 W4 W5 W6 W1 W2 1 2 3 4 5 6 9 8 7 10 11 12 13 14 15 16 4x4 6x6 1.5x4 3x6 3x8 4x4 1.5x4 3x4 7-2-0 7-2-0 10-2-0 3-0-0 14-4-0 4-2-0 -1-0-0 1-0-0 4-0-0 4-0-0 7-2-0 3-2-0 10-2-0 3-0-0 14-4-0 4-2-0 1-0-0 2-11-5 4-7-0 2-11-5 6.00 12 LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLLBCDL 38.5 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.70 0.490.52 DEFL Vert(LL) Vert(TL)Horz(TL) in -0.06 -0.170.02 (loc) 7-8 7-87 l/defl >999 >997n/a L/d 240 180n/a PLATES MT20 Weight: 62 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W1: 2 X 4 SPF No.2BRACING TOP CHORD Structural wood sheathing directly applied or 5-10-1 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-6. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.JOINTS1 Brace at Jt(s): 6 REACTIONS (lb/size)7 =683/Mechanical9 =779/0-5-8 (min. 0-1-8)Max Horz 9 =115(LC 9) Max Uplift 7 =-114(LC 10) 9 =-152(LC 9)Max Grav7 =832(LC 27)9 =937(LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD3-11=-863/173, 11-12=-849/180, 4-12=-770/184, 4-13=-753/181, 13-14=-767/178, 5-14=-835/176, 6-7=-315/67, 2-9=-278/167 BOT CHORD 8-9=-221/859, 7-8=-192/841 WEBS 3-8=-264/137, 4-8=-59/438, 5-8=-259/99, 5-7=-1015/232, 3-9=-1050/136 NOTES (15)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0,Interior(1) 2-0-0 to 3-10-8, Exterior(2) 3-10-8 to 7-2-0, Interior(1) 10-2-0 to 11-2-4 zone;cantilever left and right exposed ;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 timesflat roof load of 38.5 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.9) All bearings are assumed to be SPF No.2 . 10) Refer to girder(s) for truss to truss connections.11) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 114 lb uplift at joint 7 and 152 lb uplift at joint 9.12) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 14) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails.15) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job 28851 Truss T2C Truss Type Special Truss Qty 1 Ply 1 24 NUTTING AVE. NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jan 22 06:54:53 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:4GZrvWKYaxh?kY6tCyFvGlzuT95-xpn4Edm4Rv5PJ52T1OPsbvGMyn5lEPPuZ24H1QzsuXm Scale = 1:28.0 0-1-11 T1 T2 T3 W6 B1 W3 W4 W5 W6 W7 W7 W1 W2 1 2 3 4 5 6 7 11 10 9 8 12 13 14 15 16 4x4 6x6 1.5x4 3x6 3x8 4x4 3x4 3x4 1.5x4 3x4 7-2-0 7-2-0 8-2-0 1-0-0 14-4-0 6-2-0 -1-0-0 1-0-0 4-0-0 4-0-0 7-2-0 3-2-0 8-2-0 1-0-0 11-3-0 3-1-0 14-4-0 3-1-0 1-0-0 3-11-54-7-0 3-11-5 6.00 12 LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLLBCDL 38.5 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.32 0.450.49 DEFL Vert(LL) Vert(TL)Horz(TL) in -0.08 -0.200.02 (loc) 10-11 10-118 l/defl >999 >826n/a L/d 240 180n/a PLATES MT20 Weight: 72 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W1: 2 X 4 SPF No.2BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-7. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.JOINTS1 Brace at Jt(s): 7 REACTIONS (lb/size)8 =683/Mechanical11 =779/0-5-8 (min. 0-1-8)Max Horz 11 =141(LC 9) Max Uplift 8 =-124(LC 10) 11 =-146(LC 9)Max Grav8 =978(LC 27)11 =937(LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD3-13=-857/142, 13-14=-844/150, 4-14=-765/154, 4-5=-809/175, 5-15=-760/154, 6-15=-764/153, 2-11=-278/167 BOT CHORD 10-11=-242/854, 9-10=-155/769, 8-9=-121/608 WEBS 3-10=-265/138, 4-10=-85/583, 5-10=-443/68, 6-9=-49/374, 6-8=-970/194, 3-11=-1045/108 NOTES (15)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0,Interior(1) 2-0-0 to 3-10-8, Exterior(2) 3-10-8 to 7-2-0, Interior(1) 8-2-0 to 11-2-4 zone;cantilever left and right exposed ;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 timesflat roof load of 38.5 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for basic load combinations, which include cases withreductions for multiple concurrent live loads.6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.9) All bearings are assumed to be SPF No.2 . 10) Refer to girder(s) for truss to truss connections.11) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 124 lb uplift at joint 8 and 146 lb uplift at joint 11.12) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 14) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails.15) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard