30B-094 (4) 3a� � � gY +� RYAN S. H�ELLWIG, PE • STRUCTURAL ENGINEER • �( _ OF JM - 9 2014 RYAN S. HELL WIG Electric F NO.37300 January 8, 2014 - �A Ben Jenkins 149 Federal Street Northampton, MA Re: New Reinforcement to Existing Beam for Existing Basement Pier Removal Jenkins Residence 149 Federal Street DESIGN CRITERIA Floor dead loads: 10 psf Floor live loads: 40 psf- Unreduced Tributary widish, for beam- 'l2 of 23 feet= 11' 6" Three floors stacked on bearing wall above the existing beam Beale span= 14 feet- on center of new posts A.,.=483 sq. ft. KLL= 2 L =0.733 Lo =29 psf- Reduced Live Load -use 30 psf REINFORCEMENT DESIGN Two C9 x 15 - ASTM A36 Use wood blocking to build web out to flange tips for joist hangers blocking must bear on bottom flange Through-bolts 5l8" diameter 8" o/c - stagger 2" from top&bottom Bolt boles to be 11/16" max - located between existing joists 4 x 4 x 1/4 'Dube Steel. Posts w/ 1" x b" x 9" cap plates & 3/4"x 9" x 9" 30" x 30" or 18" x 48" Footings 1.2" thick-,v/(4) 94 rebar ea. way All reinforcements to be installed prior to removal of existing pier * 28 ALDRICH STREET i NORTHAMPTON,MA 01060 • 9 VOICE 413-584-IILWG(4594) 0 FAX 413-584-HLWFax(4593) •