Loading...
Copy (3) of IBC Code Commentary unload dockIBC Code Commentary “Section 307.1 also clarifies that hazardous materials outside of the building envelope should be classified as outdoor storage. As such, hazardous material quantities on roofs or canopies are not included in evaluating the occupancy classification of a building or structure.” COMBUSTIBLE LIQUID. A liquid having a closed cup flash point at or above 100°F (38°C). Combustible liquids shall be subdivided as follows: Class II. Liquids having a closed cup flash point at or above 100°F (38°C) and below 140°F (60°C). Class IIIA. Liquids having a closed cup flash point at or above 140°F (60°C) and below 200°F (93°C). Class IIIB. Liquids having a closed cup flash point at or above 200°F (93°C). [F] 307.4 High-hazard Group H-2. Buildings and structures containing materials that pose a deflagration hazard or a hazard from accelerated burning shall be classified as Group H-2. Such materials shall include, but not be limited to, the following: Class I, II or IIIA flammable or combustible liquids which are used or stored in normally open containers or systems, or in closed containers or systems pressurized at more than 15 psi (103.4 kPa) gage. Combustible dusts Cryogenic fluids, flammable Flammable gases Organic peroxides, Class I Oxidizers, Class 3, that are used or stored in normally open containers or systems, or in closed containers or systems pressurized at more than 15 psi (103 kPa) gage Pyrophoric liquids, solids and gases, nondetonable Unstable (reactive) materials, Class 3, nondetonable Water-reactive materials, Class 3 [F] 307.5 High-hazard Group H-3. Buildings and structures containing materials that readily support combustion or that pose a physical hazard shall be classified as Group H-3. Such materials shall include, but not be limited to, the following: Class I, II or IIIA flammable or combustible liquids that are used or stored in normally closed containers or systems pressurized at 15 pounds per square inch gauge (103.4 kPa) or less Combustible fibers, other than densely packed baled cotton Consumer fireworks, 1.4G (Class C, Common) Cryogenic fluids, oxidizing Flammable solids Organic peroxides, Class II and III Oxidizers, Class 2 Oxidizers, Class 3, that are used or stored in normally closed containers or systems pressurized at 15 pounds per square inch gauge (103 kPa) or less Oxidizing gases Unstable (reactive) materials, Class 2 Water-reactive materials, Class 2 TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS) OCCUPANCY F1 and S1 to H-2: 2 hour (w/sprinkler) F1 and S1 to H-3: 1 hour (w/sprinkler) IMC 510.2 Hazardous exhaust system; where req’d; what concentration of vapor? <25%?