approval letter January 4, 2011January 4, 2011
Ed Jazab
9 Shepherds Hollow
Leeds, MA 01053
Subject Property:
62 Chestnut Avenue Ext.
(Unit #8 Evergreen Road)
Leeds, MA 01053
Mr. Jazab
The plans for the Single
Family Residence dated 09-04-08 have been approved as noted;
Stamped engineering for I-joist submitted electronically before rough inspection.
Stamped engineering for roof truss system
submitted electronically before rough inspection.
Stamped engineering for 13R sprinkler system submitted electronically before rough inspection.
Room by room heat loss calculations
submitted electronically before rough inspection.
Structure conforms to 780 CMR 7th addition 1 and 2 family with 2009 IECC prescriptive requirements or RES Check 4.4.1 and mandatory
requirements.
Smoke and CO detectors per code, plan and as noted.
See Plan markups
Add exit landing at atrium door. Summit additional plans for landing or deck before rough inspection.
A
continuous air barrier is required behind tubs, spas, showers, fire places and electric boxes on exterior walls! Watch out or the tub comes out.
Charles Miller
Assistant Commissioner
of Buildings