091-12 120 Moser St air leakageAIR LEAKAGE REPORT Date:December 20, 2013Rating No.:091-12 Building Name:120 Moser St Rating Org.:Power House Energy Consulting Owner's Name:Phone No.:413-835-5162 Property: 120 Moser St Rater's Name:Matt Turcotte Address:Northampton, MA 01060Rater's No.:1497133 Builder's Name:Pecoy Companies Weather Site:Northampton, MARating Type:Confirmed File Name: 091-12 120 Moser St FINAL.blgRating Date:12/18/2013 REM/Rate - Residential Energy Analysis and Rating Software v12.99 This information does not constitute any warranty of energy cost or savings. © 1985-2012 Architectural Energy Corporation, Boulder, Colorado. Whole House Infiltration Blower door test Heating Cooling Natural ACH:0.06 0.04 ACH @ 50 Pascals:0.99 0.99 CFM @ 25 Pascals:261 261 CFM @ 50 Pascals:409 409 Eff. Leakage Area: [sq.in]22.5 22.5 Specific Leakage Area:0.00007 0.00007 ELA/100 sf shell: [sq.in]0.36 0.36 Duct Leakage Leakage to Outside Units ducts CFM @ 25 Pascals:0 CFM25 / CFMfan:0.0000 CFM25 / CFA:0.0000 CFM per Std 152:N/A CFM per Std 152 / CFA:N/A CFM @ 50 Pascals:0 Eff. Leakage Area: [sq.in]0.00 Thermal Efficiency:N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage:0.1191 Ventilation Mechanical:Balanced Sensible Recovery Eff. (%):67.0 Total Recovery Eff. (%):52.0 Rate (cfm):52 Hours/Day:24.0 Fan Watts:24.0 Cooling Ventilation:Natural Ventilation ASHRAE 62.2 - 2010 Ventilation Requirements For this home to comply with ASHRAE Standard 62.2 - 2010 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings, a minimum of 51 cfm of mechanical ventilation must be provided continuously, 24 hours per day. Alternatively, an intermittently operating mechanical ventilation system may be used if the ventilation rate is adjusted accordingly. For example, a 103 cfm mechanical ventilation system would need to operate 12 hours per day, as long as the system operates to provide required average ventilation once each hour.