PECOY A4 VILLAGE HILL Manual JCalculations approved by ACCA to meet all requirements of Manual J 7th Ed. 2013-May-21 11:18:29 Right-Suite® Universal 2012 12.0.11 RSU17313 Page 1 ...\Documents\Wrightsoft HVAC\RICHIE'S PECOY A4 VILLAGE HILL.rup Calc = MJ7 Front Door faces: Job:Load Short Form Date:Entire House RICHIEBy: RICHIE'S AIR CONDITIONING & HEATING 81 Industrial Lane, Agawam, Ma Project Information LOT A4 VILLAGE HILL, PECOY COMPANIESFor: NORTHAMPTON, MA Design Information InfiltrationClgHtg SimplifiedMethod870Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1270Design TD (°F) M-Daily range 5030Inside humidity (%) 2428Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80 AFUE Efficiency 0 SEER Heating input MBtuh0 Sensible cooling Btuh0 Heating output Btuh0 Latent cooling Btuh0 Temperature rise °F0 Total cooling Btuh0 Actual air flow cfm1231 Actual air flow cfm1231 Air flow factor cfm/Btuh0.019 Air flow factor cfm/Btuh0.053 Static pressure in H2O0 Static pressure in H2O0 Space thermostat Load sensible heat ratio 0.92 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) FIRST FLOOR p 754 29017 14770 561 790 BASEMENT p 504 2476 518 48 28 SECOND FLOOR p 1015 32174 14713 622 787 Entire House d 2273 63666 23019 1231 1231 Other equip loads 0 0 Equip. @ 0.92 RSM 21178 Latent cooling 1957 TOTALS 2273 63666 23135 1231 1231 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. 2013-May-21 11:18:29 Right-Suite® Universal 2012 12.0.11 RSU17313 Page 2 ...\Documents\Wrightsoft HVAC\RICHIE'S PECOY A4 VILLAGE HILL.rup Calc = MJ7 Front Door faces: Job:Load Short Form Date:BASEMENT RICHIEBy: RICHIE'S AIR CONDITIONING & HEATING 81 Industrial Lane, Agawam, Ma Project Information LOT A4 VILLAGE HILL, PECOY COMPANIESFor: NORTHAMPTON, MA Design Information InfiltrationClgHtg SimplifiedMethod870Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1270Design TD (°F) M-Daily range 5030Inside humidity (%) 2428Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling Btuh0 Heating output Btuh0 Latent cooling Btuh0 Temperature rise °F0 Total cooling Btuh0 Actual air flow cfm0 Actual air flow cfm0 Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0 Static pressure in H2O0 Static pressure in H2O0 Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) FINISHED BASEMENT 504 2476 518 48 28 BASEMENT p 504 2476 518 48 28 Other equip loads 0 0 Equip. @ 0.92 RSM 477 Latent cooling 0 TOTALS 504 2476 477 48 28 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. 2013-May-21 11:18:29 Right-Suite® Universal 2012 12.0.11 RSU17313 Page 3 ...\Documents\Wrightsoft HVAC\RICHIE'S PECOY A4 VILLAGE HILL.rup Calc = MJ7 Front Door faces: Job:Load Short Form Date:FIRST FLOOR RICHIEBy: RICHIE'S AIR CONDITIONING & HEATING 81 Industrial Lane, Agawam, Ma Project Information LOT A4 VILLAGE HILL, PECOY COMPANIESFor: NORTHAMPTON, MA Design Information InfiltrationClgHtg SimplifiedMethod870Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1270Design TD (°F) M-Daily range 5030Inside humidity (%) 2428Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling Btuh0 Heating output Btuh0 Latent cooling Btuh0 Temperature rise °F0 Total cooling Btuh0 Actual air flow cfm0 Actual air flow cfm0 Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0 Static pressure in H2O0 Static pressure in H2O0 Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) LAUNDRY/BATH 78 2241 722 43 39 KITCHEN 182 5420 2092 105 112 DINING 190 6250 3067 121 164 FAMILY 304 15105 8888 292 475 FIRST FLOOR p 754 29017 14770 561 790 Other equip loads 0 0 Equip. @ 0.92 RSM 13588 Latent cooling 989 TOTALS 754 29017 14577 561 790 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. 2013-May-21 11:18:29 Right-Suite® Universal 2012 12.0.11 RSU17313 Page 4 ...\Documents\Wrightsoft HVAC\RICHIE'S PECOY A4 VILLAGE HILL.rup Calc = MJ7 Front Door faces: Job:Load Short Form Date:SECOND FLOOR RICHIEBy: RICHIE'S AIR CONDITIONING & HEATING 81 Industrial Lane, Agawam, Ma Project Information LOT A4 VILLAGE HILL, PECOY COMPANIESFor: NORTHAMPTON, MA Design Information InfiltrationClgHtg SimplifiedMethod870Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1270Design TD (°F) M-Daily range 5030Inside humidity (%) 2428Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling Btuh0 Heating output Btuh0 Latent cooling Btuh0 Temperature rise °F0 Total cooling Btuh0 Actual air flow cfm0 Actual air flow cfm0 Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0 Static pressure in H2O0 Static pressure in H2O0 Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) BED 3 168 5414 2317 105 124 2ND FLOOR BATH 1 84 2350 738 45 39 BED 2 209 6214 3148 120 168 BED 1 266 7646 3015 148 161 2ND FLOOR BATH 2 120 3512 1269 68 68 BED 4 168 7037 4227 136 226 SECOND FLOOR p 1015 32174 14713 622 787 Other equip loads 0 0 Equip. @ 0.92 RSM 13536 Latent cooling 969 TOTALS 1015 32174 14504 622 787