29722R-VH_SHELBURNE LOT5_ROOF-RKH-072312-SEALS24 West St.West Hatfield, MA 01088 r.k. Miles, Inc. (413) 247-8300 WORK ORDER # Attn: 29722R Job:SHELBURNE FARMHOUSE Ordered On:07/22/13 10 FORD CROSSING NORTHAMPTON, MA LOT 5 BEECHWOOD AT VILLAGE HILL ANDY CLOGSTON MANUFACTURERS OF ROOF & FLOOR TRUSSES 181 GOODWIN ST PO BOX 51027 INDIAN ORCHARD, MA 01151 Phone (413) 543-1298 Fax (413) 543-1847 Toll Free (800) 456-0187 PO:43268-WRIGHT Brian TetreaultOur Salesman: Cancellation Date: Sold To: Contractor Copy of Order Phone: Ordered By:ANDY CLOGSTON 07/25/13 ** ** Truss Engineering's Shipping Department should be contacted 5 business days before your optimal delivery date. "Projected Delivery" dates are NOT scheduled ship dates. 08/24/13Projected Delivery By: *BASED ON PLANS DATED 6/26/13. *ADDITIONAL DL ADDED TO TOP CHORD OF ROOF TRUSSES FOR FUTURE SOLAR AND/OR PV PANELS FOR MAIN HOUSE AND GARAGE. SPECIAL INSTRUCTIONS: QTYTYPE SPAN LUMBER TOPBOT OVRHG / CANT LEFTRIGHT PITCH TOPBOT TRUSS ID TOTALPRICEPRICEUNITPROFILE ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL 50.0,10.0,0.0,10.0INFORMATION ROOF TRUSS SPACING:24.0 IN. O.C. (TYP.) PLY O/ABASE SPAN SHIPPING WIDTH UNIT WEIGHT LAYOUT BY: / /ON: T2 7.00 0.00 29-00-00 00-10-0800-10-08 2 X 42 X 4 COMMON 13 29-00-00 09-05-08 132 T2SGE 7.00 0.00 29-00-00 00-10-0800-10-08 2 X 42 X 4 GABLE 2 29-00-00 09-05-08 193 T3 7.00 0.00 16-00-00 00-10-0800-10-08 2 X 42 X 4 COMMON 4 16-00-00 05-08-00 71 T3GE 7.00 0.00 16-00-00 00-10-0800-10-08 2 X 42 X 4GABLE 1 16-00-00 05-08-00 69 T4 7.00 0.00 14-00-00 00-10-0800-10-08 2 X 42 X 4 Common Truss 6 14-00-00 04-11-03 49 T4GE 7.00 0.00 14-00-00 00-10-0800-10-08 2 X 42 X 4 Common Truss 1 14-00-00 04-11-03 51 ROOF SUB-TOTAL: SUB-TOTAL GRAND TOTAL ***** IMPORTANT NOTE ***** It is the sole responsibility of the retailer to supply all attached drawings and information to their customer for review and approval. Any and all changes must be received by Truss Engineering prior to the cancellation date. Any changes received after cancellation date may result in added charges and delay of order. No response before cancellation date will be perceived as a full approval of order. Truss Engineering is responsible for supplying only the material as listed on the order. Deliveries are F.O.B. our truck to jobsite. Inability to access the jobsite or take delivery of order may result in additional charges. *** THESE DRAWINGS HAVE BEEN REVIEWED AND ARE APPROVED AS AN ORDER *** Approved By:Approval Date: PO #:Requested Delivery Date: WIDE LOAD / ESCORT FEE Job Number:This non‐structural placement plan is provided for identifying the location of trusses as supplied by Truss Engineering Corporation (TEC). No responsibility is taken or implied by TEC for the structural integrity of the structure below the trusses or the affects of TEC’s product on the structure as a whole. The truss installer shall follow all BCSI recommendations, construction document specifications as well as any site specific requirements to ensure safe and proper installation. No loading shall be applied to trusses until properly and fully installed, including all sheathing, hangers, wall anchors, lateral web bracing (as shown on individual shop drawings), and permanent bracing (as required by the construction documents). Installation contractor shall refer to the individual truss shop drawings for all structural requirements of trusses,including but not limited to bearing locations and requirements, ply to ply nailing, lateral web bracing, and truss spacing. Truss Engineering Corporation strictly adheres to the ‘Standard Responsibilities in the Design of Metal Plate Connected Wood Trusses’ as defined by TPI Chapter 2 (available upon request) regardless of any job specific specifications unless clearly defined otherwise in writing by TEC.This placement plan is Truss Engineering Corporation’sINTERPRETATION of plans and drawings as supplied to us. The building owner/owner’s agent is solely responsible for verifying all dimensions, geometry, loads and load requirements for accuracy and full compliance to construction documents and shall be responsible for notifying TEC immediately of any discrepancies. The building owner/owner’s agent is responsible for coordinating all construction details between trades. Truss Engineering Corporation isNOT responsible for field verification of dimensions or special conditions. No trusses supplied by Truss Engineering Corporation may be cut, drilled, or altered in any way without first contacting TEC and receiving engineering documents allowing such.Quote Number: Q1307001 Drawn By: Brian Tetreault Job Name:Jobsite: SHELBURNE FARMHOUSE LOT 5 BEECHWOOD AT VILLAGE HILL10 FORD CROSSING NORTHAMPTONMA Job 29722 Truss T4 Truss Type Common Truss Qty 6 Ply 1 10 FORD CROSSING NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jul 23 12:23:06 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:xtF?Ld9Y6DcpPdKfIFPjw3z?7Ay-VFpydL5ePz7iMrVV?BRfNr2nnDFurj9EcYJsYVyvC4J Scale = 1:26.5 T1 T1 B1 W2 W1W1 1 2 3 4 5 6 7 8 9 10 11 12 4x4 4x4 4x4 3x8 1.5x4 1.5x4 7-0-0 7-0-0 14-0-0 7-0-0 -0-10-8 0-10-8 4-0-0 4-0-0 7-0-0 3-0-0 10-0-0 3-0-0 14-0-0 4-0-0 14-10-8 0-10-8 0-4-12 4-5-12 4-11-3 0-4-12 7.00 12 LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLLBCDL 38.5 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.24 0.470.24 DEFL Vert(LL) Vert(TL)Horz(TL) in -0.06 -0.160.02 (loc) 2-8 2-86 l/defl >999 >999n/a L/d 240 180n/a PLATES MT20 Weight: 50 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 5-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)2 =901/0-3-8 (min. 0-1-8)6 =901/0-3-8 (min. 0-1-8)Max Horz2 =-121(LC 6)Max Uplift2 =-151(LC 8)6 =-151(LC 9) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-9=-1187/179, 3-9=-1085/188, 3-10=-874/145, 4-10=-770/149, 4-11=-770/149, 5-11=-874/145, 5-12=-1085/188, 6-12=-1187/179BOT CHORD2-8=-118/932, 6-8=-89/932WEBS4-8=-78/555, 5-8=-375/154, 3-8=-375/154 WEBS4-8=-78/555, 5-8=-375/154, 3-8=-375/154 NOTES (11) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 3-10-7, Exterior(2) 3-10-7 to 7-0-0, Interior(1) 10-1-9 to 11-10-8 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 38.5 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members. 7) All bearings are assumed to be SPF No.2 . 8) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 2=151, 6=151.9) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 11) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job 29722 Truss T4GE Truss Type Common Truss Qty 1 Ply 1 10 FORD CROSSING NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jul 23 12:23:10 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:FNccDv6?0TgNlM8cX4PJ_Pz?90W-N13TTj89SBd8rSoGE1VbXhCVdqjGnYopW9H4hHyvC4F Scale = 1:26.4 T1 T1 B1 ST3 ST2 ST1 ST2 ST1 1 2 3 4 5 6 7 8 9 14 13 12 11 10 15 16 17 18 4x4 3x4 3x4 14-0-0 14-0-0 -0-10-8 0-10-8 7-0-0 7-0-0 14-0-0 7-0-0 14-10-8 0-10-8 0-4-12 4-5-12 4-11-3 0-4-12 7.00 12 LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLLBCDL 38.5 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.12 0.060.07 DEFL Vert(LL) Vert(TL)Horz(TL) in -0.01 -0.010.00 (loc) 9 98 l/defl n/r n/rn/a L/d 120 90n/a PLATES MT20 Weight: 52 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2OTHERS2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS All bearings 14-0-0.(lb) - Max Horz2=-121(LC 6)Max UpliftAll uplift 100 lb or less at joint(s) 2, 8, 13, 14, 11, 10Max GravAll reactions 250 lb or less at joint(s) 12 except 2=258(LC 1), 8=258(LC 1), 13=282(LC 2), 14=336(LC 2), 11=282(LC 3), 10=336(LC 3) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS4-13=-250/81, 3-14=-274/120, 6-11=-250/81, 7-10=-274/119 NOTES (15) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Corner(3) -0-10-8 to 2-1-8,Exterior(2) 2-1-8 to 4-0-0, Corner(3) 4-0-0 to 7-0-0, Exterior(2) 10-0-0 to 11-10-8 zone;cantilever left and right exposed ;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.33 plate grip DOL=1.332) Truss designed for wind loads in the plane of the truss only. For studs exposed towind (normal to the face), see Standard Industry Gable End Details as applicable, orconsult qualified building designer as per ANSI/TPI 1.3) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 38.5 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated.7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 2-0-0 oc.9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.10) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.11) All bearings are assumed to be SPF No.2 . 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8, 13, 14, 11, 10. 13) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 14) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 15) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard T2SGE T2SGE T3GE T2(13) T3(4) 13-00-0016-00-00 29-00-00 7- 0 0 - 0 0 28 - 0 0 - 0 0 35 - 0 0 - 0 0 35 - 0 0 - 0 0 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 1-10-08 1-08 2-00-00 Job Number:This non‐structural placement plan is provided for identifying the location of trusses as supplied by Truss Engineering Corporation (TEC). No responsibility is taken or implied by TEC for the structural integrity of the structure below the trusses or the affects of TEC’s product on the structure as a whole. The truss installer shall follow all BCSI recommendations, construction document specifications as well as any site specific requirements to ensure safe and proper installation. No loading shall be applied to trusses until properly and fully installed, including all sheathing, hangers, wall anchors, lateral web bracing (as shown on individual shop drawings), and permanent bracing (as required by the construction documents). Installation contractor shall refer to the individual truss shop drawings for all structural requirements of trusses,including but not limited to bearing locations and requirements, ply to ply nailing, lateral web bracing, and truss spacing. Truss Engineering Corporation strictly adheres to the ‘Standard Responsibilities in the Design of Metal Plate Connected Wood Trusses’ as defined by TPI Chapter 2 (available upon request) regardless of any job specific specifications unless clearly defined otherwise in writing by TEC.This placement plan is Truss Engineering Corporation’sINTERPRETATION of plans and drawings as supplied to us. The building owner/owner’s agent is solely responsible for verifying all dimensions, geometry, loads and load requirements for accuracy and full compliance to construction documents and shall be responsible for notifying TEC immediately of any discrepancies. The building owner/owner’s agent is responsible for coordinating all construction details between trades. Truss Engineering Corporation isNOT responsible for field verification of dimensions or special conditions. No trusses supplied by Truss Engineering Corporation may be cut, drilled, or altered in any way without first contacting TEC and receiving engineering documents allowing such.Quote Number: Q1307001 Drawn By: Brian Tetreault Job Name:Jobsite: SHELBURNE FARMHOUSE LOT 5 BEECHWOOD AT VILLAGE HILL10 FORD CROSSING NORTHAMPTONMA Job 29722 Truss T2 Truss Type COMMON TRUSS Qty 13 Ply 1 10 FORD CROSSING NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jul 23 12:23:31 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:xtF?Ld9Y6DcpPdKfIFPjw3z?7Ay-G3qPtvPKWeG9shvIzyNWu6auzIkSCv7vLxthvZyvC3w Scale = 1:54.9 T1 T1 B1 W5 W4 W3 W4 W3 W1 W2 W1 W2B1 1 2 3 4 5 6 7 12 11 10 9 8 13 14 15 16 17 18 19 20 21 22 4x6 4x4 5x8 3x6 5x6 3x6 5x6 4x9 4x4 4x9 7-6-0 7-6-0 14-6-0 7-0-0 21-6-0 7-0-0 29-0-0 7-6-0 -0-10-8 0-10-8 7-6-0 7-6-0 14-6-0 7-0-0 21-6-0 7-0-0 29-0-0 7-6-0 29-10-8 0-10-8 1-0-0 9-5-8 1-0-0 7.00 12 ADDITIONAL 7 PSF TCDL FOR FUTURE SOLAR/PV PANELS Plate Offsets (X,Y): [2:0-3-12,0-1-12], [6:0-3-12,0-1-12], [10:0-4-0,0-3-0] LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL BCDL 38.5 17.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix-M) 0.910.680.70 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.12-0.250.08 (loc) 9-109-108 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 132 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF 2100F 1.8EBOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W5,W4: 2 X 4 SPF No.2, W1: 2 X 6 SPF No.2BRACING TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 5-10, 3-10 REACTIONS (lb/size)12 =2062/0-3-8 (min. 0-3-4)8 =2062/0-3-8 (min. 0-3-4)Max Horz 12 =-242(LC 6) Max Uplift 12 =-223(LC 8) 8 =-223(LC 9) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-13=-2756/257, 13-14=-2553/269, 3-14=-2390/285, TOP CHORD2-13=-2756/257, 13-14=-2553/269, 3-14=-2390/285, 3-15=-2011/266, 15-16=-1797/280, 4-16=-1787/292, 4-17=-1787/292, 17-18=-1797/280, 5-18=-2011/266, 5-19=-2390/285, 19-20=-2553/269, 6-20=-2756/257, 2-12=-1992/278, 6-8=-1992/278 BOT CHORD11-12=-290/607, 11-21=-130/2205, 10-21=-130/2205, 10-22=-130/2205, 9-22=-130/2205, 8-9=-141/607WEBS4-10=-117/1106, 5-10=-927/164, 3-10=-927/164, 2-11=-42/1628, 6-9=-42/1628 NOTES (11)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 11-6-0, Exterior(2) 11-6-0 to 14-6-0, Interior(1) 17-6-0 to 26-10-8 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 38.5 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.7) All bearings are assumed to be SPF No.2 . 8) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 12=223, 8=223.9) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 11) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard Job 29722 Truss T2SGE Truss Type GABLE Qty 2 Ply 1 10 FORD CROSSING NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jul 23 12:22:36 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:xtF?Ld9Y6DcpPdKfIFPjw3z?7Ay-NU?cK5kqTlLzmECkFuud9WoUs7ybp1Vpit2HUFyvC4n Scale = 1:54.9 T1 T1 B1 W5 W4 W3 W4 W3 W1 W2 W1 W2B1 ST8 ST9 ST6 ST7 ST4 ST5ST3ST2 ST1 ST8 ST9 ST6 ST7 ST4 ST5 ST3 ST2 ST1 1 2 3 4 5 6 7 12 11 10 9 8 43 44 45 46 47 48 49 50 51 52 4x6 4x4 5x8 3x6 5x6 3x6 5x6 4x9 4x4 4x9 7-6-0 7-6-0 14-6-0 7-0-0 21-6-0 7-0-0 29-0-0 7-6-0 -0-10-8 0-10-8 7-6-0 7-6-0 14-6-0 7-0-0 21-6-0 7-0-0 29-0-0 7-6-0 29-10-8 0-10-8 1-0-0 9-5-8 1-0-0 7.00 12 ADDITIONAL 7 PSF TCDL FOR FUTURE SOLAR/PV PANELS Plate Offsets (X,Y): [2:0-3-12,0-1-12], [6:0-3-12,0-1-12], [10:0-4-0,0-3-0] LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL BCDL 38.5 17.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix-M) 0.910.680.70 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.12-0.250.08 (loc) 9-109-108 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 194 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF 2100F 1.8EBOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W5,W4: 2 X 4 SPF No.2, W1: 2 X 6 SPF No.2 OTHERS 2 X 4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied, except end verticals.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 5-10, 3-10 REACTIONS (lb/size)12 =2062/0-3-8 (min. 0-3-4)8 =2062/0-3-8 (min. 0-3-4) Max Horz 12 =-242(LC 6) Max Uplift 12 =-223(LC 8)8 =-223(LC 9) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-43=-2756/257, 43-44=-2553/269, 3-44=-2390/285, TOP CHORD2-43=-2756/257, 43-44=-2553/269, 3-44=-2390/285, 3-45=-2011/266, 45-46=-1797/280, 4-46=-1787/292, 4-47=-1787/292, 47-48=-1797/280, 5-48=-2011/266, 5-49=-2390/285, 49-50=-2553/269, 6-50=-2756/257, 2-12=-1992/278, 6-8=-1992/278 BOT CHORD11-12=-290/607, 11-51=-130/2205, 10-51=-130/2205, 10-52=-130/2205, 9-52=-130/2205, 8-9=-141/607WEBS4-10=-117/1106, 5-10=-927/164, 3-10=-927/164, 2-11=-42/1628, 6-9=-42/1628 NOTES (14)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 11-6-0, Exterior(2) 11-6-0 to 14-6-0, Interior(1) 17-6-0 to 26-10-8 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.332) Truss designed for wind loads in the plane of the truss only. For studs exposed towind (normal to the face), see Standard Industry Gable End Details as applicable, orconsult qualified building designer as per ANSI/TPI 1.3) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 38.5 psf on overhangs non-concurrent with other live loads.6) All plates are 1.5x4 MT20 unless otherwise indicated.7) Gable studs spaced at 2-0-0 oc.8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.9) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf. 10) All bearings are assumed to be SPF No.2 . 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 223 lb uplift at joint 12 and 223 lb uplift at joint 8. 12) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.13) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 14) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job 29722 Truss T3 Truss Type COMMON TRUSS Qty 4 Ply 1 10 FORD CROSSING NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jul 23 12:22:54 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:xtF?Ld9Y6DcpPdKfIFPjw3z?7Ay-ry5Q6Fy7DHcPw?aBIgDruJYgVN7_1BbTrgPE7CyvC4V Scale = 1:34.3 T1 T1 B1 W4 W3W3 W1 W2 W1 W2 1 2 3 4 5 6 7 10 9 8 11 12 13 14 15 16 17 18 4x4 3x8 4x4 4x4 2x4 3x6 2x4 3x6 8-0-0 8-0-0 16-0-0 8-0-0 -0-10-8 0-10-8 4-0-0 4-0-0 8-0-0 4-0-0 12-0-0 4-0-0 16-0-0 4-0-0 16-10-8 0-10-8 1-0-0 5-8-0 1-0-0 7.00 12 ADDITIONAL 7 PSF TCDL FOR FUTURE SOLAR/PV PANELS LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLLBCDL 38.5 17.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.45 0.600.60 DEFL Vert(LL) Vert(TL)Horz(TL) in -0.10 -0.250.03 (loc) 9-10 9-108 l/defl >999 >745n/a L/d 240 180n/a PLATES MT20 Weight: 71 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W1: 2 X 6 SPF No.2BRACING TOP CHORD Structural wood sheathing directly applied or 5-7-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)10 =1141/0-3-8 (min. 0-1-13)8 =1141/0-3-8 (min. 0-1-13)Max Horz10 =-133(LC 6)Max Uplift10 =-162(LC 8) 8 =-162(LC 9) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD3-12=-1009/140, 12-13=-945/143, 13-14=-889/147, 4-14=-871/154,4-15=-871/154, 15-16=-889/147, 16-17=-945/143, 5-17=-1009/140, 2-10=-294/141, 6-8=-294/141BOT CHORD9-10=-122/973, 8-9=-82/973 BOT CHORD9-10=-122/973, 8-9=-82/973WEBS 4-9=-56/506, 5-9=-335/158, 3-9=-335/158, 3-10=-1252/105, 5-8=-1252/105 NOTES (11) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -0-10-8 to 2-1-8,Interior(1) 2-1-8 to 5-0-0, Exterior(2) 5-0-0 to 8-0-0, Interior(1) 11-0-0 to 13-10-8 zone;cantilever left and right exposed ;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 38.5 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.7) All bearings are assumed to be SPF No.2 . 8) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 162 lb uplift at joint 10 and 162 lb uplift at joint 8. 9) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 11) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job 29722 Truss T3GE Truss Type GABLE Qty 1 Ply 1 10 FORD CROSSING NORTHAMPTON, MA Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Tue Jul 23 12:22:59 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:xtF?Ld9Y6DcpPdKfIFPjw3z?7Ay-CvuJ9y0F2pEi0mT95Dp0bNFcDOyYiZzC?y6?oPyvC4Q Scale = 1:34.3 T1 T1 B1 W1 W1 ST4 ST3 ST2 ST1 ST3 ST2 ST1 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 21 22 4x4 2x4 2x4 3x4 3x4 16-0-0 16-0-0 -0-10-8 0-10-8 8-0-0 8-0-0 16-0-0 8-0-0 16-10-8 0-10-8 1-0-0 5-8-0 1-0-0 7.00 12 ADDITIONAL 7 PSF TCDL FOR FUTURE SOLAR/PV PANELS LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLLBCDL 38.5 17.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.13 0.070.14 DEFL Vert(LL) Vert(TL)Horz(TL) in -0.01 -0.010.00 (loc) 11 1112 l/defl n/r n/rn/a L/d 120 90n/a PLATES MT20 Weight: 69 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 6 SPF No.2OTHERS2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS All bearings 16-0-0.(lb) - Max Horz20=-133(LC 6)Max UpliftAll uplift 100 lb or less at joint(s) 20, 12, 17, 18, 19, 15, 14, 13Max Grav All reactions 250 lb or less at joint(s) 19, 13 except 20=256(LC 2), 12=256(LC 3), 16=360(LC 1), 17=371(LC 2), 18=279(LC 2), 15=371(LC 3), 14=279(LC 3) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.WEBS5-17=-293/73, 7-15=-293/73 NOTES (16) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Corner(3) -0-10-8 to 2-0-0,Exterior(2) 2-0-0 to 5-0-0, Corner(3) 5-0-0 to 8-0-0, Exterior(2) 11-0-0 to 13-10-8 zone;cantilever left and right exposed ;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.33 plate grip DOL=1.332) Truss designed for wind loads in the plane of the truss only. For studs exposed towind (normal to the face), see Standard Industry Gable End Details as applicable, orconsult qualified building designer as per ANSI/TPI 1.3) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 38.5 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated.7) Gable requires continuous bottom chord bearing. 8) Truss to be fully sheathed from one face or securely braced against lateral movement(i.e. diagonal web).9) Gable studs spaced at 2-0-0 oc.10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads.11) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 12) All bearings are assumed to be SPF No.2 . 13) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 12, 17, 18, 19, 15, 14, 13. 14) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.15) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 16) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard