Loading...
Binder1 06061140' 32' 37' 14'21'-9" 12' 13'-6" 20'-6" 5' 17' Scale 1/4":1'-0" New Foundation Existing House 6'-6" 14' 4" Poured Concrete Floor 2 x 10 Floor Joists 12" o.c. up 3 1/2" Lally Column Beam pocket (3) 2x10 Flush Beam Beam pocket (3) 2x10 Flush Beam 2 x 10 Floor Joists 16" o.c. 30 x 30 x 12 Concrete Pad 2 x 10 Floor Joists 16" o.c. 8" Poured Concrete Walls 2'-5" 3' 6' 3' 6' 3' 8'-11" 5' 4'-9" 4'-3" ƒ 18" x 8" Continuos Footings Porch deck above up Bulk Door Exist Stairs to remove + 0'-0" Gable Trussed Roof System Blocking 2"x 6" Top plate 2"x 6" Trusses notched over top plate Fascia 2 x 6 " Header 2 (2x10"s) Roof system finished with asphalt shingles Soffit applied to underside of overhang Exterior wall insulation R-25 minimum Vinyl siding to match existing + 18'- 4" + 8'-0" Sole plate Insulation within attic subfloor only "I" Wood joist upper floor system Header 2" x 12" Double top plate 2"x 6" +26'-4" Exterior Wall insularion R-25 Sole plate Finished floor Subfloor 3/4" plywood PT Header 2" x 12" "I" Wood joist first floor system PT Sill plate 2"x 6" 8'' above grade 8' Concrete Finished ceiling basement wall 18 x 8 Concrete continuos footing 1/2" Expansion joint 4' Poured Concrete floor 1'- 2" 8'-0" 8'-0" Scale 1/2":1'-0" Foundation ƒ ƒ ƒ ƒ 28'-0" 36'-4" EARLE STREET Nor t h a m p t o n - E a s t h a m p t o n B i k e P a t h 18 4 ' - 6 " 13 2 ' - 4 " 10 0 ' - 0 " 100' - 0" NOT TO SCALE Existing Existing House Addition 5'-0" Same for FIRST and SECOND Levels Unfinished at this level ATTIC / STORAGE Interior Finish 5/8" Gwb painted BASEMENT Subfloor 3/4" plywood Sill plate insulation Sill seal 1" + 9'-2" + 17'-2" A.0 3 A.0 2 A.0 1 project: owner: General Notes Scale: Varies Home Addition Polly Parker & Jonathan Yourga A.0 FOUNDATION Key location: 188 Earle Street, Northampton MA 01060 contractor: Richard Ruth Mass Lic. # General Building Information a) Building Use : Residential b) Square footage : Existing 1,950 + Addition 2,950 = 4,900 sf c) Building height : below 36 ft d) Number of floors above grade : Two e) Number of floors below grade : One f) Type of construction: Type II g) Hazardous material use and storage : Low hazard. drafting: 'DQLHO*yPH]/(('$3 Revisions 06/06/2011 New walls Project objective. Drawings are schematic in nature and indicate design intent. If changes are Applicable Laws, Regulations and Standards a) 780 CMR, Seventh Edition, b) NFPA Codes and Standards d) 527 CMR. Fire prevention regulations, c) MGL., Chapter 148 .- Fire prevention, Demo walls Existent walls required due to different field conditions, suggested changes are to be submitted to owner's representative for approval prior to any changes being performed. Scale 1/4":1'-0" 40' 32' 5' 20'-6" Kitchen Foyer Kitchen ToiletBath 16'-6" 11'-6" 40' 25'-6" 37' 20'-6" 20'-6" 5' Scale 1/4":1'-0" 6'-6" 4' 9' 7'-9" 9'-8" 9' 11'-6" 7' 19'-6" 13'-2" bench Living Room closet Master Bedroom closet Bedroom Bedroom Linen Laundry closet up down Bedroom wic Bath upup 4' 8' 6' 5' 11'-8" 3'2'-6"2'-6"5'-5"3'1'-6"9'2'-6"9' 19'-6" 1'-8" 1' 3' 1' 40' 14'-3"1'-11" 2'-10" down 3' 9' 5'-11" 3' 3' 6' 2'-9" 4'-5" 32'-8" 37'37' 3' 2'-6" 6' 2'-6" 10'-6" 2'-6" 5' 3' 3'2'-6"5'3'2'-7"3'4'-1"2'-4"3'-1"6' 1'-7" 36'-1"3'-11" ƒ Exist Stairs to remove 10'-2" 11'-6" Pull down attic stairs Bath 15'-2" 10' 3'-6" 6'-8" 4'-6" 3'-5" 4'-9"14'-4" 13'-2" 11'-10" 5'6'-5" 3' 3'-8"3'-8" 3'-9" 5' 13'-6" 10'-10" 9'-10" 5'-8" 5'-6" 9' 8'-8" 5' 2'-6" 10'-6" 2'-6" 5' 37' 7'-3"6'7'-3" 9'-11"2'-6"1'-8"2'-6"3' 19'-6" 3'2'-6"1'-8"2'-6"6'-5"3'6" 19'-6" 3'-7"2'-4"3'-1"6'1'-7"3'-11" 3' 3' 3' 3' 6' 3' 3' 6' 2'-9" 4'-5" Living Bedroom Bedroom Existing Bulk Head Door A.1 2 A.1 1 A AAA See sections for stairs run ( dwg A.3 ) B B B B project: owner: General Notes Scale: 1/4"= 1'-0" Home Addition Polly Parker & Jonathan Yourga A.1 FLOOR PLANS Key location: 188 Earle Street, Northampton MA 01060 contractor: Richard Ruth Mass Lic. # General Building Information a) Building Use : Residential b) Square footage : Existing 1,950 + Addition 2,950 = 4,900 sf c) Building height : below 36 ft d) Number of floors above grade : Two e) Number of floors below grade : One f) Type of construction: Type II g) Hazardous material use and storage : Low hazard. drafting: 'DQLHO*yPH]/(('$3 Revisions 06/06/2011 New walls Drawings are schematic in nature and indicate design intent. If changes are Applicable Laws, Regulations and Standards a) 780 CMR, Seventh Edition, b) NFPA Codes and Standards d) 527 CMR. Fire prevention regulations, c) MGL., Chapter 148 .- Fire prevention, Demo walls Existent walls required due to different field conditions, suggested changes are to be submitted to owner's representative for approval prior to any changes being performed. 40' 25'-6" 37' 20'-6" 20'-6" 4' Scale 1/4":1'-0" 5'-6" Pull down attic stairs 37' 9'2'-6"9' 19'-6" 19'-6" 9'2'-6"5'-1"3'-11" 9' 3' 6' 3' 6' 3' 2'-9" 4'-5" 1' 1' 1' 27'-6" 20'-6" 11'9'-6" 1' 20'-6" Cricket Ridge Attic Storage slope slope slope slope slope A.2 1 40' 25'-6" 37' 20'-6" 20'-6" 4' Scale 1/4":1'-0" 6'-6" 37' 11'-3"11'-3" 18'-6" 18'-6" 11'-3"6'-4"4'-11" 39' 1' 1' 1' 27'-6" 19'-6" 11'8'-6" 1' 19'-6" Cricket Ridge slope slope slope slope slope A.2 1 slope slope 1'1' 1' 1' 1'1' 1' A A( Unfinished ) project: owner: General Notes Scale: 1/4"= 1'-0" Home Addition Polly Parker & Jonathan Yourga A.2 FLOOR PLANS Key location: 188 Earle Street, Northampton MA 01060 contractor: Richard Ruth Mass Lic. # General Building Information a) Building Use : Residential b) Square footage : Existing 1,950 + Addition 2,950 = 4,900 sf c) Building height : below 36 ft d) Number of floors above grade : Two e) Number of floors below grade : One f) Type of construction: Type II g) Hazardous material use and storage : Low hazard. drafting: 'DQLHO*yPH]/(('$3 Revisions 06/06/2011 New walls Drawings are schematic in nature and indicate design intent. If changes are Applicable Laws, Regulations and Standards a) 780 CMR, Seventh Edition, b) NFPA Codes and Standards d) 527 CMR. Fire prevention regulations, c) MGL., Chapter 148 .- Fire prevention, Demo walls Existent walls required due to different field conditions, suggested changes are to be submitted to owner's representative for approval prior to any changes being performed. EXISTING 8' 8' Attic Storage Bedrooom Kitchen New Basement Attic Bedroom Living Basement Hall Foyer 12 8 Align Align New Cricket 7' + 0' - 00" - (8' - 2") + 9' - 2" - Ground Level Varies + 18' - 4" + 26' - 4" + 33' - 10" 8' Exist Stairs to remove Stairs up Stairs 6'-8" min headroom 8' 1'-2" 8' 1'-2" 8' 1'-2" 7'-1" + 0' - 00" - (8' - 2") + 9' - 2" - Ground Level Varies + 18' - 4" + 33' - 10" Attic Storage WIC Existing KitchenBath Bath Hall Cl Kitchen New BasementBasement 7'-1" Pull down attic stairs 3 1/2" Lally Columns Flush Beam + 26' - 4" Scale 1/4":1'-0"Scale 1/4":1'-0"A.3 B A.3 A 14 risers 13 treads 11 risers 10 treads step down 18 Trusses type Fink2 End Trusses type Gable tige project: owner: General Notes Scale: 1/4"= 1'-0" Home Addition Polly Parker & Jonathan Yourga A.3 SECTIONS Key location: 188 Earle Street, Northampton MA 01060 contractor: Richard Ruth Mass Lic. # General Building Information a) Building Use : Residential b) Square footage : Existing 1,950 + Addition 2,950 = 4,900 sf c) Building height : below 36 ft d) Number of floors above grade : Two e) Number of floors below grade : One f) Type of construction: Type II g) Hazardous material use and storage : Low hazard. drafting: 'DQLHO*yPH]/(('$3 Revisions 06/06/2011 Drawings are schematic in nature and indicate design intent. If changes are Applicable Laws, Regulations and Standards a) 780 CMR, Seventh Edition, b) NFPA Codes and Standards d) 527 CMR. Fire prevention regulations, c) MGL., Chapter 148 .- Fire prevention, required due to different field conditions, suggested changes are to be submitted to owner's representative for approval prior to any changes being performed. + 0' - 00" + 9' - 2" + 18' - 4" + 26' - 4" + 33' - 10" + 0' - 00" + 9' - 2" + 18' - 4" + 26' - 4" + 33' - 10" 7'-6" 8' 9'-2" 9'-2" 33'-10" + 0' - 00" + 9' - 2" + 17' -2" + 24' -8" 7'-6" 8' 9'-2" 24'-8" 7'-6" 8' 9'-2" 9'-2" 33'-10" Scale 1/4":1'-0"Scale 1/4":1'-0"A.4 B A.4 A project: owner: General Notes Scale: 1/4"= 1'-0" Home Addition Polly Parker & Jonathan Yourga A.4 ELEVATIONS Key location: 188 Earle Street, Northampton MA 01060 contractor: Richard Ruth Mass Lic. # General Building Information a) Building Use : Residential b) Square footage : Existing 1,950 + Addition 2,950 = 4,900 sf c) Building height : below 36 ft d) Number of floors above grade : Two e) Number of floors below grade : One f) Type of construction: Type II g) Hazardous material use and storage : Low hazard. drafting: 'DQLHO*yPH]/(('$3 Revisions 06/06/2011 Drawings are schematic in nature and indicate design intent. If changes are Applicable Laws, Regulations and Standards a) 780 CMR, Seventh Edition, b) NFPA Codes and Standards d) 527 CMR. Fire prevention regulations, c) MGL., Chapter 148 .- Fire prevention, required due to different field conditions, suggested changes are to be submitted to owner's representative for approval prior to any changes being performed. + 0' - 00" + 9' - 2" + 18' - 4" + 26' - 4" + 33' - 10" 7'-6" 8' 9'-2" 9'-2" 33'-10" + 0' - 00" + 9' - 2" + 17' -2" + 24' -8" 7'-6" 8' 9'-2" 24'-8" Scale 1/4":1'-0"Scale 1/4":1'-0"A.5 2 A.5 1 + 0' - 00" + 9' - 2" + 17' -2" + 24' -8" 7'-6" 8' 9'-2" 24'-8" project: owner: General Notes Scale: 1/4"= 1'-0" Home Addition Polly Parker & Jonathan Yourga A.5 ELEVATIONS Key location: 188 Earle Street, Northampton MA 01060 contractor: Richard Ruth Mass Lic. # General Building Information a) Building Use : Residential b) Square footage : Existing 1,950 + Addition 2,950 = 4,900 sf c) Building height : below 36 ft d) Number of floors above grade : Two e) Number of floors below grade : One f) Type of construction: Type II g) Hazardous material use and storage : Low hazard. drafting: 'DQLHO*yPH]/(('$3 Revisions 06/06/2011 Drawings are schematic in nature and indicate design intent. If changes are Applicable Laws, Regulations and Standards a) 780 CMR, Seventh Edition, b) NFPA Codes and Standards d) 527 CMR. Fire prevention regulations, c) MGL., Chapter 148 .- Fire prevention, required due to different field conditions, suggested changes are to be submitted to owner's representative for approval prior to any changes being performed.