Loading...
32 Walnut-RKH-052011-SEALS24 West St.West Hatfield, MA 01088 r.k. Miles, Inc. (413) 247-8300 WORK ORDER # Attn: 25567 Job:GREG AND MARIE QUILL Ordered On:05/18/11 WALNUT ST. NORTHAMPTON, MA ANDY CLOGSTON MANUFACTURERS OF ROOF & FLOOR TRUSSES 181 GOODWIN ST PO BOX 51027 INDIAN ORCHARD, MA 01151 Phone (413) 543-1298 Fax (413) 543-1847 Toll Free (800) 456-0187 PO:RU-43547 F Brian TetreaultOur Salesman: Cancellation Date: Sold To: Contractor Copy of Order Phone: Ordered By:ANDY CLOGSTON 06/01/11Requested Delivery: 05/21/11 Scheduled Delivery:06/01/11 ** Truss Engineering's Shipping Department has confirmed this as the ACTUAL ship date. Please contact us IMMEDIATELY if this date needs to be changed. ** SHIP WITH 25567SPECIAL INSTRUCTIONS: QTY DEPTH O/A LEFTRIGHT CANTILEVER LEFTRIGHTTRUSS ID TOTALPRICEPRICEUNITEND TYPEPROFILEFLOOR FLOOR TRUSSES LOADING 40.0,12.0,0.0,5.0INFORMATION FLOOR TRUSS SPACING:16.0 IN. O.C. (TYP.) PLY SPANSPANBASE UNIT WEIGHT TCLL-TCDL-BCLL-BCDL LAYOUT BY: / /ON: F1 01-06-00 25-00-00 21 25-00-00 F1GE 01-06-00 25-00-00 2 25-00-00 F2 01-06-00 16-00-00 5 16-00-00 F3GE 01-06-00 06-06-00 2 06-06-00 FG1 2 01-06-00 25-00-002 Ply 25-00-00 FG2 01-03-00 06-06-00 1 06-06-00 FLOOR SUB-TOTAL: ITEM TYPEQTYITEM NAME NOTES PRICEUNITTOTALPRICE ITEMS FTC CLIP Floor Hangers 8 2-PLY FLOOR TRUSS CONNECTOR - 750# THAC422 Hanger 2 ITEMS SUB-TOTAL: SUB-TOTAL GRAND TOTAL ***** IMPORTANT NOTE ***** It is the sole responsibility of the retailer to supply all attached drawings and information to their customer for review and approval. Any and all changes must be received by Truss Engineering prior to the cancellation date. Any changes received after cancellation date may result in added charges and delay of order. No response before cancellation date will be perceived as a full approval of order. Truss Engineering is responsible for supplying only the material as listed on the order. Deliveries are F.O.B. our truck to jobsite. Inability to access the jobsite or take delivery of order may result in additional charges. Job Number: 25566 This non‐structural placement plan is provided for identifying the location of trusses as supplied by Truss Engineering Corporation (TEC). No responsibility is taken or implied by TEC for the structural integrity of the structure below the trusses or the affects of TEC’s product on the structure as a whole. The truss installer shall follow all BCSI recommendations, construction document specifications as well as any site specific requirements to ensure safe and proper installation. No loading shall be applied to trusses until properly and fully installed, including all sheathing, hangers, wall anchors, lateral web bracing (as shown on individual shop drawings), and permanent bracing (as required by the construction documents). Installation contractor shall refer to the individual truss shop drawings for all structural requirements of trusses, including but not limited to bearing locations and requirements, ply to ply nailing, lateral web bracing, and truss spacing. Truss Engineering Corporation strictly adheres to the ‘Standard Responsibilities in the Design of Metal Plate Connected Wood Trusses’ as defined by TPI Chapter 2 (available upon request) regardless of any job specific specifications unless clearly defined otherwise in writing by TEC. This placement plan is Truss Engineering Corporation’sINTERPRETATION of plans and drawings as supplied to us. The building owner/owner’s agent is solely responsible for verifying all dimensions, geometry, loads and load requirements for accuracy and full compliance to construction documents and shall be responsible for notifying TEC immediately of any discrepancies. The building owner/owner’s agent is responsible for coordinating all construction details between trades. Truss Engineering Corporation isNOT responsible for field verification of dimensions or special conditions. No trusses supplied by Truss Engineering Corporation may be cut, drilled, or altered in any way without first contacting TEC and receiving engineering documents allowing such. Quote Number: Q1103002 Drawn By: Brian Tetreault Job Name: Jobsite: GREG AND MARIE QUILL WALNUT ST. NORTHAMPTONMA 2 PLY FLOOR TRUSS FTC CONNECTION DETAIL ST-FTC_CLIP REFER TO INDIVIDUAL TRUSS DESIGN FOR PLATE SIZES AND LUMBER GRADES 1- 0 - 0 M I N . ABCDEFGHI RQPONMLKJ S T MAX. CONCENTRATED LOAD AS PER CHART BELOW TRUSS SIZE MAX. CONC. LOAD ( lb's. ) PER CLIP USP FLOOR TRUSS CLIPS - FTC SERIES 3 x 2 ( 2 ) 3 x 2 4 x 2 FTC32 FTC32-2 FTC1 1360 1360 1730 1180 1180 1500 SYP / DOUG-FIR SPF 4 5/8" 4 3 /8" 3" 2 1/1 6" 4 5/8" 4 3/8" 1 1/2" 2 1/1 6 " ( 2 ) 4 x 2 USP STOCK NO. FTC217301500 MAX. TRANSFER LOAD ( lb's. ) PER CLIP 680 680 865 590 590 750 SYP / DOUG-FIR SPF 865750 MAX. UNIFORM LOAD ( plf ) 24" O.C. SPACING 680 680 865 590 590 750 SYP / DOUG-FIR SPF 865750 TRUSS SIZE 3 x 2 ( 2 ) 3 x 2 4 x 2 FTC32 FTC32-2 FTC1 ( 10 ) 10d x 1-1/2" ( 10 ) 10d x 1-1/2" ( 10 ) 10d FASTENER SCHEDULE ( 2 ) 4 x 2 USP STOCK NO. FTC2( 10 ) 10d FOLLOW USP INSTALLATION INSTRUCTIONS. USE ALL SPECIFIED FASTENERS. MAX. UNIFORM LOAD ( plf ) REQUIRES FTC CLIPS TO BE PLACED AT A 24" O.C. MAX. SPACING ALONG THE LOADED CHORD. FTC32 / FTC1 FTC32-2 / FTC2 MAX. UNIFORM LOAD AS PER CHART BELOW 10d x 1-1/2" NAILS ARE 9 GAUGE ( 0.148" DIAMETER) BY 1-1/2" LONG MiTek Industries, Inc. R MiTek Industries, Chesterfield, MO Page 1 of 1 JANUARY 1, 2009 Job 25566 Truss F1 Truss Type FLOOR Qty 21 Ply 1 WALNUT ST. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Thu May 19 11:13:17 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:ysqqeRuLPeFWKsR7QC_ZdozfMwt-ZJXIaXAYA?_A7e_jK6mxZKuDeWYWw5NGUT2L4ZzEzHm Scale = 1:31.1 B1 BL1 BL1 T1 W3 B2 T212345678910 11 12 20 19 18 17 16 15 14 13 21 22 3x12 MT20H FP3x6 3x6 FP 3x6 4x9 4x9 4x9 4x9 3x4 3x6 3x6 3x4 3x4 10-6-0 12-7-8 25-0-0 25-0-0 2-6-0 1-10-8 2-0-0 0-1-8 0-1-8 1-6-0 1-6-0 Plate Offsets (X,Y): [1:Edge,0-0-12], [6:0-1-8,Edge], [17:0-1-8,Edge], [21:0-1-8,0-0-12], [22:0-1-8,0-0-12] LOADING (psf) TCLLTCDLBCLLBCDL 40.012.00.05.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 1-4-0 1.001.00YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.590.750.39 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.47-0.770.11 (loc) 15-1615-1613 l/defl >629>387n/a L/d 480360n/a PLATES MT20MT20H Weight: 97 lb FT = 4%F, 10%E GRIP 197/144148/108 LUMBERTOP CHORD 4 X 2 SPF 1650F 1.5EBOT CHORD 4 X 2 SPF 1650F 1.5E *Except* B2: 4 X 2 SPF 2100F 1.8E WEBS 4 X 2 SPF No.2BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)20 =936/0-5-8 (min. 0-1-8)13 =936/0-5-8 (min. 0-1-8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 2-3=-2832/0, 3-4=-2832/0, 4-5=-4177/0, 5-6=-4177/0, 6-7=-4143/0, 7-8=-4143/0, 8-9=-4143/0, 9-10=-2833/0, 10-11=-2833/0 BOT CHORD19-20=0/1623, 18-19=0/3655, 17-18=0/3655, 16-17=0/4177, 15-16=0/4177, 14-15=0/3655, 13-14=0/1625WEBS11-13=-1831/0, 2-20=-1828/0, 11-14=0/1371, 9-14=-933/0, WEBS11-13=-1831/0, 2-20=-1828/0, 11-14=0/1371, 9-14=-933/0, 4-19=-934/0, 9-15=0/554, 4-17=0/793, 6-15=-457/310, 2-19=0/1372 NOTES (8) 1) Unbalanced floor live loads have been considered for this design.2) All plates are MT20 plates unless otherwise indicated. 3) All plates are 1.5x4 MT20 unless otherwise indicated.4) All bearings are assumed to be SPF No.2 . 5) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 7) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 8) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard Job 25566 Truss F2 Truss Type FLOOR TRUSS Qty 5 Ply 1 WALNUT ST. NORTHAMPTON, MA Job Reference (optional) 7.250 s Nov 19 2010 MiTek Industries, Inc. Wed May 18 09:24:14 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:pDq0VijfDn5_LfO_GyLxAJzKYZt-ST6rDopzMUWxIpyq_HGFqH_qydDnjxSsGtEjSBzFK_? B1 BL1 T1 T2 W5W4W3 586#/0#590#/0# 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10 16 1.5x4 3x6 1.5x4 6x6 3x4 3x4 3x4 1.5x4 5x6 1.5x4 3x4 3x6 1.5x4 3x4 4x4 5x6 10-6-0 10-4-8 10-4-8 10-6-0 0-1-8 11-4-8 0-10-8 12-3-0 0-10-8 14-5-0 2-2-0 15-7-8 1-2-8 16-0-0 0-4-8 2-6-0 1-10-8 0-8-0 1-3-0 1-3-0 0-1-8 0-4-0 1-6-0 1-3-0 1-6-0 Plate Offsets (X,Y): [1:Edge,0-0-12], [9:0-1-2,Edge], [12:0-1-8,Edge], [13:0-1-8,Edge], [16:0-1-8,0-0-12] LOADING (psf) TCLLTCDLBCLLBCDL 40.012.00.05.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 1-4-0 1.001.00YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.980.780.25 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.30-0.510.04 (loc) 13-1413-149 l/defl >617>363n/a L/d 480360n/a PLATES MT20 Weight: 63 lb FT = 4%F, 10%E GRIP 197/144 LUMBERTOP CHORD 4 X 2 SPF 1650F 1.5EBOT CHORD 4 X 2 SPF 1650F 1.5EWEBS4 X 2 SPF No.2BRACING TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)15 =586/0-3-8 (min. 0-1-8)9 =590/0-3-8 (min. 0-1-8) FORCES (lb) - First Load Case OnlyTOP CHORD15-16=-70, 1-16=-70, 1-2=-3, 2-3=-1526, 3-4=-1526, 4-5=-1348, 5-6=-1348, 6-7=-1348, 7-8=-466, 8-9=-469 BOT CHORD 14-15=969, 13-14=1693, 12-13=1348, 11-12=953,10-11=0WEBS5-13=86, 6-12=-570, 2-15=-1090, 2-14=632, WEBS5-13=86, 6-12=-570, 2-15=-1090, 2-14=632, 3-14=-146, 4-14=-189, 4-13=-391, 9-11=676, 7-11=-723, 7-12=842 NOTES (7) 1) Unbalanced floor live loads have been considered for thisdesign.2) This truss is designed in accordance with the 2009International Residential Code sections R502.11.1 andR802.10.2 and referenced standard ANSI/TPI 1.3) "Semi-rigid pitchbreaks with fixed heels" Member end fixitymodel was used in the analysis and design of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in.6) CAUTION, Do not erect truss backwards.7) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job 25566 Truss FG2 Truss Type Floor Truss Qty 1 Ply 1 WALNUT ST. NORTHAMPTON, MA Job Reference (optional) 7.250 s Nov 19 2010 MiTek Industries, Inc. Wed May 18 09:17:01 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:pDq0VijfDn5_LfO_GyLxAJzKYZt-e9S9KlZMKRyNsHMc7r?jnzYt24Wsm2G7i?sIlnzFK4m B1 W1 W1 T1 W3W2W3 1554#/0#1894#/0# 1 2 3 4 5 9 8 7 6 10 113x4 4x9 3x4 4x9 4x6 4x6 3x4 1.5x4 1.5x4 6-6-0 6-6-0 2-0-0 0-9-0 1-6-0 1-3-0 1-3-0 Plate Offsets (X,Y): [1:Edge,0-1-8], [2:0-1-8,Edge], [6:Edge,0-1-8], [7:0-1-8,Edge], [9:Edge,0-1-8] LOADING (psf) TCLLTCDLBCLLBCDL 40.012.00.05.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.001.00NOIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.800.500.45 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.05-0.080.02 (loc) 6-76-76 l/defl >999>993n/a L/d 480360n/a PLATES MT20 Weight: 31 lb FT = 4%F, 10%E GRIP 197/144 LUMBERTOP CHORD 4 X 2 SYP 2850F 2.3EBOT CHORD 4 X 2 SPF 1650F 1.5EWEBS4 X 2 SPF No.2BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)9 =1441/Mechanical6 =1703/MechanicalMax Grav9 =1554(LC 2)6 =1894(LC 3) FORCES (lb) - First Load Case Only TOP CHORD 1-9=-351, 5-6=-535, 1-10=0, 2-10=0, 2-3=-2100, 3-11=-2100, 4-11=-2100, 4-5=0BOT CHORD8-9=2100, 7-8=2100, 6-7=1661 BOT CHORD8-9=2100, 7-8=2100, 6-7=1661 WEBS 4-6=-2020, 2-9=-2361, 4-7=542, 2-8=27, 3-7=-309 NOTES (6)1) Unbalanced floor live loads have been considered for thisdesign.2) Refer to girder(s) for truss to truss connections.3) This truss is designed in accordance with the 2009International Residential Code sections R502.11.1 andR802.10.2 and referenced standard ANSI/TPI 1.4) "Semi-rigid pitchbreaks with fixed heels" Member end fixitymodel was used in the analysis and design of this truss. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means.6) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard 1) Floor: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 6-9=-10, 1-5=-104 Concentrated Loads (lb) Vert: 5=-486 4=-486 2=-486 10=-486 11=-486 Job 25566 Truss FG1 Truss Type FLOOR TRUSS Qty 2 Ply 2 WALNUT ST. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Wed May 18 09:50:35 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:pDq0VijfDn5_LfO_GyLxAJzKYZt-cm4iiiVN20KNLFZgESgCjxy2gxnhevLapLjtR2zFJbI Scale = 1:31.7 B1 BL1 BL1 T1 W4W3W4 B2 T21234567891011 12 13 22 21 20 19 18 17 16 15 14 23 24 25 3x12 MT20H FP 1.5x4 3x6 1.5x4 1.5x4 1.5x4 3x6 FP 4x6 1.5x4 1.5x4 4x4 4x9 4x9 1.5x4 4x6 3x6 4x9 4x12 1.5x4 4x4 4x9 4x4 3x4 3x6 THAC422 10-6-0 10-4-8 10-4-8 10-6-0 0-1-8 11-4-8 0-10-8 12-3-0 0-10-8 15-10-4 3-7-4 25-0-0 9-1-12 2-6-0 1-10-8 1-11-8 1-1-0 1-1-0 0-1-8 0-1-8 1-6-0 1-6-0 APPLY FTC CLIPS AS FOLLOWS:(2) EACH SIDE OF LOAD CARRYING VERTICAL TOP AND BOTTOM CHORD Plate Offsets (X,Y): [1:Edge,0-0-12], [6:0-1-8,Edge], [7:0-1-8,Edge], [17:0-1-8,Edge], [19:0-1-8,Edge], [23:0-1-8,0-0-12], [24:0-1-8,0-0-12] LOADING (psf) TCLLTCDLBCLLBCDL 40.012.00.05.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 1-4-0 1.001.00NOIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.810.900.48 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.45-0.730.09 (loc) 17-1817-1814 l/defl >661>409n/a L/d 480360n/a PLATES MT20MT20H Weight: 239 lb FT = 4%F, 10%E GRIP 197/144187/143 LUMBERTOP CHORD 4 X 2 SYP 2850F 2.3EBOT CHORD 4 X 2 SYP 2850F 2.3EWEBS4 X 2 SPF No.2BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)22 =1486/0-3-8 (min. 0-1-8)14 =1911/0-3-8 (min. 0-1-8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-3=-4882/0, 3-4=-4882/0, 4-5=-8640/0, 5-6=-8640/0, 6-7=-10022/0, 7-8=-10141/0, 8-9=-10141/0, 9-10=-10141/0, 10-11=-6448/0, 11-12=-6448/0 BOT CHORD 21-22=0/2649, 20-21=0/6740, 19-20=0/6740, 18-19=0/8640, 17-18=0/8640, 16-17=0/10022, 15-16=0/9032, 14-15=0/3457WEBS5-19=-712/0, 6-18=-579/0, 2-22=-2986/0, 2-21=0/2535, 4-21=-2108/0, 4-19=0/2398, 12-14=-3898/0, 12-15=0/3394, WEBS5-19=-712/0, 6-18=-579/0, 2-22=-2986/0, 2-21=0/2535, 4-21=-2108/0, 4-19=0/2398, 12-14=-3898/0, 12-15=0/3394, 10-15=-2932/0, 10-16=0/1635, 7-17=-757/0, 6-17=0/2058, 8-16=-1439/0, 7-16=0/293 NOTES (11)1) Trusses to be fastened together to act as a single unit. All loads to be distributedequally over the 2 plies.2) Unbalanced floor live loads have been considered for this design.3) All plates are MT20 plates unless otherwise indicated. 4) All bearings are assumed to be SPF No.2 . 5) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 7) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means.8) Use Simpson Strong-Tie THAC422 (6-16d Girder, 6-16d Truss) or equivalent at15-10-4 from the left end to connect truss(es) FG2 (1 ply 4 X 2 SPF) to back face of topchord, skewed 0.0 deg.to the left, sloping 0.0 deg. down. 9) WARNING: The following hangers are manually applied but fail due to geometricconsiderations: THAC422 on back face at 15-10-4 from the left end. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).11) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard1) Floor: Lumber Increase=1.00, Plate Increase=1.00Uniform Loads (plf)Vert: 14-22=-7, 1-13=-69Concentrated Loads (lb) Vert: 8=-1508(B) 25=-17 Job 25566 Truss F1GE Truss Type GABLE Qty 2 Ply 1 WALNUT ST. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Thu May 19 11:13:26 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:ysqqeRuLPeFWKsR7QC_ZdozfMwt-o2aiTcHC2m6ui0ARMVR2QEmu18oJXFRaYMkJuYzEzHd Scale = 1:31.3 B1 BL1 BL1 T1 B2 T2 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 43 44 3x4 3x6 FP 3x4 3x6 FP 1-4-0 1-4-0 2-8-0 1-4-0 4-0-0 1-4-0 5-4-0 1-4-0 6-8-0 1-4-0 8-0-0 1-4-0 9-4-0 1-4-0 10-8-0 1-4-0 12-0-0 1-4-0 13-4-0 1-4-0 14-8-0 1-4-0 16-0-0 1-4-0 17-4-0 1-4-0 18-8-0 1-4-0 20-0-0 1-4-0 21-4-0 1-4-0 22-8-0 1-4-0 24-0-0 1-4-0 25-0-0 1-0-0 0-1-8 0-1-8 1-6-0 1-6-0 Plate Offsets (X,Y): [1:Edge,0-0-12], [43:0-1-8,0-0-12], [44:0-1-8,0-0-12] LOADING (psf) TCLLTCDLBCLLBCDL 40.012.00.05.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 1-4-0 1.001.00YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.040.000.01 DEFL Vert(LL)Vert(TL)Horz(TL) in n/an/a0.00 (loc) - - 22 l/defl n/an/an/a L/d 999999n/a PLATES MT20 Weight: 88 lb FT = 4%F, 10%E GRIP 197/144 LUMBERTOP CHORD 4 X 2 SPF 1650F 1.5EBOT CHORD 4 X 2 SPF 1650F 1.5E *Except* B2: 4 X 2 SPF 2100F 1.8E WEBS 4 X 2 SPF No.2 OTHERS 4 X 2 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS All bearings 25-0-0.(lb) - Max GravAll reactions 250 lb or less at joint(s) 42, 22, 41, 40, 39, 38, 37, 36, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23 FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES (9) 1) All plates are 1.5x4 MT20 unless otherwise indicated.2) Gable requires continuous bottom chord bearing. 3) Truss to be fully sheathed from one face or securely braced against lateral movement(i.e. diagonal web).4) Gable studs spaced at 1-4-0 oc.5) All bearings are assumed to be SPF No.2 . 6) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 8) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to eachtruss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outerends or restrained by other means.9) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard Job 25566 Truss F3GE Truss Type GABLE Qty 2 Ply 1 WALNUT ST. NORTHAMPTON, MA Job Reference (optional) 7.250 s Nov 19 2010 MiTek Industries, Inc. Wed May 18 09:17:45 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:pDq0VijfDn5_LfO_GyLxAJzKYZt-Ld6nZo6zzyV781j3i4n1ZFNZRqek42ocprWdIEzFK44 B1 W1 W1 T1 ST1 ST1 ST1 ST1 1 2 3 4 5 6 12 11 10 9 8 7 3x4 3x4 3x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 1-4-0 1-4-0 2-8-0 1-4-0 4-0-0 1-4-0 5-4-0 1-4-0 6-6-0 1-2-0 1-6-0 1-6-0 Plate Offsets (X,Y): [1:Edge,0-1-8], [12:Edge,0-1-8] LOADING (psf) TCLLTCDLBCLLBCDL 40.012.00.05.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.001.00YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.070.010.02 DEFL Vert(LL)Vert(TL)Horz(TL) in n/an/a0.00 (loc) - - 7 l/defl n/an/an/a L/d 999999n/a PLATES MT20 Weight: 26 lb FT = 4%F, 10%E GRIP 197/144 LUMBERTOP CHORD 4 X 2 SPF No.2BOT CHORD 4 X 2 SPF No.2WEBS4 X 2 SPF No.2 OTHERS 4 X 2 SPF No.2BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS All bearings 6-6-0.(lb) - Max GravAll reactions 250 lb or less at joint(s) 12, 7, 11, 10, 9, 8 FORCES (lb) - First Load Case Only TOP CHORD 1-12=-58, 6-7=-49, 1-2=-7, 2-3=-7, 3-4=-7, 4-5=-7, 5-6=-7BOT CHORD11-12=7, 10-11=7, 9-10=7, 8-9=7, 7-8=7 BOT CHORD11-12=7, 10-11=7, 9-10=7, 8-9=7, 7-8=7 WEBS 2-11=-137, 3-10=-139, 4-9=-142, 5-8=-126 NOTES (7) 1) Gable requires continuous bottom chord bearing. 2) Truss to be fully sheathed from one face or securely bracedagainst lateral movement (i.e. diagonal web).3) Gable studs spaced at 1-4-0 oc.4) This truss is designed in accordance with the 2009International Residential Code sections R502.11.1 andR802.10.2 and referenced standard ANSI/TPI 1.5) "Semi-rigid pitchbreaks with fixed heels" Member end fixitymodel was used in the analysis and design of this truss. 6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means.7) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard