Loading...
GH roof trussesSPECIAL INSTRUCTIONS: *BASED ON 5/18/11 FOR BUILDING SET. *DRAWINGS PROVIDED ARE NOT FOR CONSTRUCTION-FOR REVIEW ONLY. QUOTE # Q1103376 PAGE 1 DATE QUOTED:05/31/11 VALID UNTIL:06/28/11 PRINTED ON:05/31/11 24 West St. West Hatfield, MA 01088 r.k. Miles, Inc. (413) 247-8300 Attn:DOUG HODGINS MANUFACTURERS OF ROOF & FLOOR TRUSSES 181 GOODWIN ST PO BOX 51027 INDIAN ORCHARD, MA 01151 Phone (413) 543-1298 Fax (413) 543-1847 Toll Free (800) 456-0187 Quote To: Phone: Job:GREER HELMUTH RESIDENCE 158 BAKER HILL ROAD EXT. NORTHAMPTON, MA JEFFREY BOTT CONTRACTING Brian TetreaultQuoted By: Requested By:DOUG HODGINS CONTRACTOR QUOTE QTYTYPE SPAN LUMBER TOPBOT OVRHG / CANT LEFTRIGHT PITCH TOPBOT TRUSS IDPROFILE ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL 40.0,10.0,0.0,10.0 STRESS INCR. 1.15INFORMATION ROOF TRUSS SPACING:24.0 IN. O.C. (TYP.) PLY O/ABASE SPAN UNIT WEIGHT SHIPPING HEIGHT LAYOUTBRT05/31/11 0110.00 0.00 04-04-15 01-04-00 2 X 42 X 4 Jack-Open 4 04-04-15 1405-02-00 0210.00 0.00 02-04-15 01-04-00 2 X 42 X 4 Jack-Open 4 02-04-15 903-06-00 0310.00 0.00 06-06-00 01-04-00 2 X 42 X 4 Jack-Closed 2 06-06-00 2606-10-14 03A10.00 0.00 06-06-002 X 42 X 4 Jack-Closed 7 06-06-00 2406-05-00 04 7.07 0.00 01-07-11 01-10-10 2 X 42 X 4 Jack-Open 1 01-07-11 702-05-00 05 6.09 0.00 02-01-04 01-00-00 2 X 42 X 4 Jack-Open 2 02-01-04 601-10-13 06 5.00 0.00 02-00-02 01-04-00 2 X 42 X 4 Jack-Open 2 02-00-02 601-08-08 07 5.00 0.00 04-06-08 01-04-00 2 X 42 X 4 Jack-Closed 4 04-06-08 1402-09-03 10 7.00 0.00 01-02-04 01-04-00 2 X 42 X 4 Jack-Open 1 01-02-04 602-04-05 11 7.00 0.00 02-06-11 01-04-00 2 X 42 X 4 Jack-Open 1 02-06-11 903-01-14 12 7.00 0.00 04-00-00 01-04-00 2 X 42 X 4 Jack-Closed 4 04-00-00 1704-00-00 13 4.79 0.00 03-05-02 01-04-00 2 X 42 X 4 Jack-Open 1 03-05-02 1002-09-08 20 7.00 0.00 05-03-11 01-04-00 2 X 42 X 4 Jack-Closed 8 05-03-11 1904-02-09 21 7.00 0.00 03-03-11 01-04-00 2 X 42 X 4 Jack-Open 8 03-03-11 1003-00-09 22 7.00 0.00 01-03-11 01-04-00 2 X 42 X 4 Jack-Open 8 01-03-11 501-10-09 23 7.00 0.00 07-04-12 01-04-00 2 X 42 X 4 Jack-Closed 6 07-04-12 3105-05-02 CJ1 7.07 0.00 09-00-13 01-10-10 2 X 42 X 4 Diagonal Hip 2 09-00-13 4606-09-08 CJ2 3.86 0.00 05-09-05 01-08-07 2 X 42 X 4 Diagonal Hip 2 05-09-05 2102-08-09 CJ3 3.95 0.00 06-10-13 00-00-09 02-04-05 2 X 42 X 4 Diagonal Hip 1 06-10-13 3403-11-04 CJ4 4.95 0.00 10-04-00 01-10-10 2 X 42 X 6 Diagonal Hip 4 10-04-00 5305-04-04 SPECIAL INSTRUCTIONS: *BASED ON 5/18/11 FOR BUILDING SET. *DRAWINGS PROVIDED ARE NOT FOR CONSTRUCTION-FOR REVIEW ONLY. QUOTE # Q1103376 PAGE 2 DATE QUOTED:05/31/11 VALID UNTIL:06/28/11 PRINTED ON:05/31/11 24 West St. West Hatfield, MA 01088 r.k. Miles, Inc. (413) 247-8300 Attn:DOUG HODGINS MANUFACTURERS OF ROOF & FLOOR TRUSSES 181 GOODWIN ST PO BOX 51027 INDIAN ORCHARD, MA 01151 Phone (413) 543-1298 Fax (413) 543-1847 Toll Free (800) 456-0187 Quote To: Phone: Job:GREER HELMUTH RESIDENCE 158 BAKER HILL ROAD EXT. NORTHAMPTON, MA JEFFREY BOTT CONTRACTING Brian TetreaultQuoted By: Requested By:DOUG HODGINS CONTRACTOR QUOTE QTYTYPE SPAN LUMBER TOPBOT OVRHG / CANT LEFTRIGHT PITCH TOPBOT TRUSS IDPROFILE ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL 40.0,10.0,0.0,10.0 STRESS INCR. 1.15INFORMATION ROOF TRUSS SPACING:24.0 IN. O.C. (TYP.) PLY O/ABASE SPAN UNIT WEIGHT SHIPPING HEIGHT LAYOUTBRT05/31/11 G1 1 10.00 0.00 29-00-00 01-04-0001-04-00 2 X 42 X 6 Hip Truss 2 Ply 29-00-00 16906-10-14 G2 1 6.09 0.00 13-09-002 X 42 X 6 Hip Truss 2 Ply 13-09-00 5402-04-01 G20 2 7.00 0.00 18-09-08 01-04-0001-04-00 2 X 42 X 6 Hip Truss 2 Ply 18-09-08 9905-05-02 G3 1 10.00 0.00 19-08-002 X 62 X 8 Hip Truss 2 Ply 19-08-00 21413-02-04 H110.00 0.00 29-00-00 01-04-0001-04-00 2 X 42 X 4 Hip Truss 1 29-00-00 15008-06-14 H210.00 0.00 30-06-00 01-04-0001-04-00 2 X 42 X 4 Hip Truss 1 30-06-00 16310-02-14 H310.00 0.00 30-06-00 01-04-0001-04-00 2 X 42 X 4 Hip Truss 1 30-06-00 18211-10-14 H4G10.00 0.00 34-00-08 01-04-0001-04-00 2 X 42 X 4 Special Truss 1 34-00-08 18711-02-15 H510.00 0.00 34-00-08 01-04-00 2 X 42 X 4 Special Truss 1 34-00-08 17711-02-15 H610.00 0.00 34-11-00 01-04-00 2 X 42 X 4 Special Truss 1 34-11-00 17011-02-15 H710.00 0.00 34-11-00 01-04-00 2 X 42 X 4 Special Truss 1 34-11-00 17911-02-15 M110.00 0.00 13-07-082 X 42 X 4 Half Hip Truss 7 13-07-08 7810-03-04 M2 4.79 0.00 12-03-12 01-04-00 2 X 42 X 4 Monopitch 1 12-03-12 6106-04-01 M3-3.50 0.00 19-04-002 X 42 X 4 Monopitch 1 19-04-00 9108-10-11 M3G 1 -3.50 0.00 18-04-13 00-00-122 X 42 X 6 Monopitch 2 Ply 18-04-13 12708-07-06 S110.0010.00 16-06-082 X 42 X 4 Special Truss 1 16-06-08 7908-04-11 S210.0010.00 16-06-082 X 62 X 4 Special Truss 1 16-06-08 8708-04-11 S310.0010.00 16-06-082 X 62 X 4 Special Truss 1 16-06-08 9108-04-11 S4 0.0010.00 16-06-082 X 42 X 4 Special Truss 1 16-06-08 11207-06-01 S5 0.0010.00 16-06-082 X 62 X 4 Special Truss 1 16-06-08 11309-02-01 SPECIAL INSTRUCTIONS: *BASED ON 5/18/11 FOR BUILDING SET. *DRAWINGS PROVIDED ARE NOT FOR CONSTRUCTION-FOR REVIEW ONLY. QUOTE # Q1103376 PAGE 3 DATE QUOTED:05/31/11 VALID UNTIL:06/28/11 PRINTED ON:05/31/11 24 West St. West Hatfield, MA 01088 r.k. Miles, Inc. (413) 247-8300 Attn:DOUG HODGINS MANUFACTURERS OF ROOF & FLOOR TRUSSES 181 GOODWIN ST PO BOX 51027 INDIAN ORCHARD, MA 01151 Phone (413) 543-1298 Fax (413) 543-1847 Toll Free (800) 456-0187 Quote To: Phone: Job:GREER HELMUTH RESIDENCE 158 BAKER HILL ROAD EXT. NORTHAMPTON, MA JEFFREY BOTT CONTRACTING Brian TetreaultQuoted By: Requested By:DOUG HODGINS CONTRACTOR QUOTE QTYTYPE SPAN LUMBER TOPBOT OVRHG / CANT LEFTRIGHT PITCH TOPBOT TRUSS IDPROFILE ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL 40.0,10.0,0.0,10.0 STRESS INCR. 1.15INFORMATION ROOF TRUSS SPACING:24.0 IN. O.C. (TYP.) PLY O/ABASE SPAN UNIT WEIGHT SHIPPING HEIGHT LAYOUTBRT05/31/11 S6 0.0010.00 16-06-082 X 62 X 4 Special Truss 1 16-06-08 13110-10-01 S6A 0.0010.00 16-06-082 X 62 X 4 Special Truss 1 16-06-08 14110-10-01 S7 0.0010.00 16-06-082 X 62 X 4 Special Truss 1 16-06-08 14912-06-01 S7A 0.0010.00 16-06-082 X 62 X 4 Special Truss 1 16-06-08 16112-06-01 S8 0.0010.00 16-06-082 X 42 X 4 Half Hip Truss 1 16-06-08 16213-07-14 S9 0.0010.00 16-06-082 X 62 X 4 Special Truss 1 16-06-08 12310-01-05 T110.00 0.00 31-10-08 01-04-00 2 X 42 X 4 Special Truss 1 31-10-08 18313-06-14 T1010.00 0.00 21-08-08 01-04-00 2 X 42 X 4 Special Truss 2 21-08-08 13010-08-13 T10A10.00 0.00 22-07-002 X 42 X 4 Special Truss 3 22-07-00 12410-02-15 T1110.00 0.00 21-08-08 04-08-00 01-04-00 2 X 42 X 4 Special Truss 2 21-08-08 13110-08-13 T11A10.00 0.00 17-00-082 X 42 X 4 Special Truss 3 21-08-08 11110-02-15 T12A10.00 0.00 29-10-00 00-00-062 X 42 X 4 Special Truss 1 29-10-00 16110-02-15 T12B10.00 0.00 29-11-13 00-00-062 X 42 X 4Special Truss 1 29-11-13 16110-02-15 T12C10.00 0.00 28-05-04 00-00-062 X 42 X 4 Special Truss 1 28-05-04 16010-02-15 T12D10.00 0.00 27-11-13 00-00-062 X 42 X 4 Special Truss 1 27-11-13 16010-02-15 T12E10.00 0.00 25-11-13 00-00-062 X 42 X 4 Special Truss 1 25-11-13 14410-02-15 T12F10.00 0.00 23-11-13 00-00-062 X 42 X 4 Special Truss 1 23-11-13 13410-02-15 T12G**.** 0.00 21-04-002 X 42 X 4 Special Truss 1 21-04-00 11710-04-12 T210.00 0.00 31-10-08 01-04-00 2 X 42 X 4 Special Truss 1 31-10-08 19313-06-14 SPECIAL INSTRUCTIONS: *BASED ON 5/18/11 FOR BUILDING SET. *DRAWINGS PROVIDED ARE NOT FOR CONSTRUCTION-FOR REVIEW ONLY. QUOTE # Q1103376 PAGE 4 DATE QUOTED:05/31/11 VALID UNTIL:06/28/11 PRINTED ON:05/31/11 24 West St. West Hatfield, MA 01088 r.k. Miles, Inc. (413) 247-8300 Attn:DOUG HODGINS MANUFACTURERS OF ROOF & FLOOR TRUSSES 181 GOODWIN ST PO BOX 51027 INDIAN ORCHARD, MA 01151 Phone (413) 543-1298 Fax (413) 543-1847 Toll Free (800) 456-0187 Quote To: Phone: Job:GREER HELMUTH RESIDENCE 158 BAKER HILL ROAD EXT. NORTHAMPTON, MA JEFFREY BOTT CONTRACTING Brian TetreaultQuoted By: Requested By:DOUG HODGINS CONTRACTOR QUOTE QTYTYPE SPAN LUMBER TOPBOT OVRHG / CANT LEFTRIGHT PITCH TOPBOT TRUSS IDPROFILE ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL 40.0,10.0,0.0,10.0 STRESS INCR. 1.15INFORMATION ROOF TRUSS SPACING:24.0 IN. O.C. (TYP.) PLY O/ABASE SPAN UNIT WEIGHT SHIPPING HEIGHT LAYOUTBRT05/31/11 T20 7.00 0.00 18-09-08 01-04-0001-04-00 2 X 42 X 4 Common Truss 4 18-09-08 8306-07-02 T310.00 0.00 30-06-00 01-04-0001-04-00 2 X 42 X 4 Special Truss 1 30-06-00 19013-06-14 T410.00 0.00 30-06-00 01-04-0001-04-00 2 X 42 X 4 Special Truss 1 30-06-00 20613-06-14 T510.00 0.00 19-08-00 01-04-00 2 X 42 X 4 Special Truss 1 19-08-00 19013-06-14 T6GE10.00 0.00 05-04-00 01-04-0001-04-00 2 X 42 X 4 Common Truss 1 05-04-00 2203-08-09 T7GE10.00 0.00 10-00-00 01-04-0001-04-00 2 X 42 X 4 Common Truss 1 10-00-00 4605-07-14 T8GE10.00 0.00 11-01-022 X 42 X 4 Common Truss 1 11-01-02 4805-07-07 T9SGE10.00 0.00 22-02-04 01-04-00 2 X 42 X 4 GABLE 1 22-02-04 15010-08-13 FT-IN-16 ITEM TYPEQTYSIZE LENGTH PART NUMBER NOTES ITEMS HUS26Std Roof Hangers 10 1-PLY HEAVY DUTY - 1950# IN 2x6 / 2695# IN 2x8 LUS26Hanger 20 LUS26Std Roof Hangers 10 1-PLY LIGHT DUTY - 805# IN 2x6 / 890# IN 2x8 SKHH28LSlope/Skew Roof 2 HEAVY DUTY 45 DEGREES SKEW LEFT - 2170# IN 2x6 / 2510# IN 2x8 SUL26Hanger 4 SUR26Hanger 4 THJA26Hanger 6 THJU26-WHanger 3 *** THESE DRAWINGS HAVE BEEN REVIEWED AND ARE APPROVED AS AN ORDER *** Approved By:Approval Date: SUB-TOTAL GRAND TOTAL PO #: DOUBLE ESCORT Truss Engineering Corporation (TEC) strictly adheres to the 'Standard Responsibilities in the Design of Metal Plate Connected Wood Trusses' as defined by TPI Chapter 2 (available upon request) regardless of any job specific specifications unless clearly defined otherwise in writing by TEC. This product list is Truss Engineering Corporation's INTERPRETATION of plans and drawings as supplied to us. No responsibility is taken or implied by TEC for the structural integrity of the structure below the trusses or the affects of TEC's product on the structure as a whole. The building owner/owner's agent is solely responsible for verifying all dimensions, geometry, loads and load requirements for accuracy and full compliance to construction documents and shall be responsible for notifying TEC immediately of any discrepancies. Truss Engineering Corporation is NOT responsible for field verification of dimensions or special conditions. The building owner/owner's agent is responsible for coordinating all construction details between trades. The truss installer shall follow all BCSI recommendations, construction document specifications as well as any site specific requirements to ensure safe and proper installation. No loading shall be applied to trusses until properly and fully installed, including all sheathing, hangers, wall anchors, lateral web bracing (as shown on individual shop drawings), and permanent bracing (as required by the construction documents). Installation contractor shall refer to the individual truss shop drawings for all structural requirements of trusses, including but not limited to bearing locations and requirements, ply to ply nailing, lateral web bracing, and truss spacing. No trusses supplied by Truss Engineering Corporation may be cut, drilled, or altered in any way without first contacting TEC and receiving engineering documents allowing such. Requested Delivery Date: T1 G1 H1 H2 H3 CJ 1 CJ1 01 02 01 02 01 02 0102 CJ3 11 10 13 CJ2 06 05 C J 2 05 06 T2 T3 T4 T5 04 G3 G2 T6 G E S1 S2 S3 S4 S5 S6 S7S8 S7 A S6 A T7 GE T8GE T9 SGEH4G H5 H6H7 M2 T12 A T12 C T12 B T12 DT12ET12 F T12 G M3M3 G S9 1-06-001-06-005-00-0013-09-0010-03-00 4-04-00 11 - 0 8 - 0 0 10 - 0 5 - 0 8 5- 0 4 - 0 0 3-11-08 9- 0 3 - 0 0 4-09-08 91 - 0 7 - 0 3 15 - 0 7 - 0 8 24 - 0 7 - 0 0 4-09-08 29-00-00 40 - 0 8 - 0 0 40 - 0 8 - 0 0 12-10-08 15 - 0 7 - 0 8 2- 0 6 - 0 0 7-06 -0 0 5-03 -0 0 10 -00-00 5-00-00 11- 0 1 - 0 2 11- 0 1 - 0 2 11- 1 0 - 0 4 10-11 -00 11-09-12 18-09-08 15-0 1-04 12-08- 0 8 03(2) 03A(7) M1(7) T10A(3)T10(2) T11(2) 12(4) T11A(3) 07(4) 2-06-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-0 0-00 WA L L H E I G H T I S 12 " L O W E R T H A N GA R A G E CO V E N T I O N A L L Y F R A M E D 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 Job Number:This non‐structural placement plan is provided for identifying the location of trusses as supplied by Truss Engineering Corporation (TEC). No responsibility is taken or implied by TEC for the structural integrity of the structure below the trusses or the affects of TEC’s product on the structure as a whole. The truss installer shall follow all BCSI recommendations, construction document specifications as well as any site specific requirements to ensure safe and proper installation. No loading shall be applied to trusses until properly and fully installed, including all sheathing, hangers, wall anchors, lateral web bracing (as shown on individual shop drawings), and permanent bracing (as required by the construction documents). Installation contractor shall refer to the individual truss shop drawings for all structural requirements of trusses,including but not limited to bearing locations and requirements, ply to ply nailing, lateral web bracing, and truss spacing. Truss Engineering Corporation strictly adheres to the ‘Standard Responsibilities in the Design of Metal Plate Connected Wood Trusses’ as defined by TPI Chapter 2 (available upon request) regardless of any job specific specifications unless clearly defined otherwise in writing by TEC.This placement plan is Truss Engineering Corporation’sINTERPRETATION of plans and drawings as supplied to us. The building owner/owner’s agent is solely responsible for verifying all dimensions, geometry, loads and load requirements for accuracy and full compliance to construction documents and shall be responsible for notifying TEC immediately of any discrepancies. The building owner/owner’s agent is responsible for coordinating all construction details between trades. Truss Engineering Corporation isNOT responsible for field verification of dimensions or special conditions. No trusses supplied by Truss Engineering Corporation may be cut, drilled, or altered in any way without first contacting TEC and receiving engineering documents allowing such.Quote Number: Q1103376 Drawn By: Brian Tetreault Job Name:Jobsite: GREER HELMUTHRESIDENCE JEFFREY BOTT CONTRACTING158 BAKER HILL ROAD EXT. NORTHAMPTONMA Job Q1103376 Truss 01 Truss Type Jack-Open Truss Qty 4 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 13:04:17 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-S6yA54ge9W_z5lrqpArhNv8bb7IShQw88iF1mYzCIvi Scale = 1:24.9 W1 T1 B11 2 5 3 4 4x4 3x4 4-4-15 4-4-15 -1-4-0 1-4-0 4-4-15 4-4-15 1-0-0 4-8-2 5-2-0 4-2-5 10.00 12 LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLLBCDL 30.8 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.36 0.230.00 DEFL Vert(LL) Vert(TL)Horz(TL) in 0.03 -0.04-0.04 (loc) 4-5 4-53 l/defl >999 >999n/a L/d 240 180n/a PLATES MT20 Weight: 14 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 4-4-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)5 =355/0-5-8 (min. 0-1-8)3 =144/Mechanical4 =48/MechanicalMax Horz5 =199(LC 8)Max Uplift5 =-36(LC 8) 3 =-108(LC 8) 4 =-5(LC 8) Max Grav 5 =355(LC 1)3 =144(LC 1)4 =79(LC 4) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD2-5=-319/99 NOTES (12) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members. 7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 36 lb uplift at joint 5, 108 lb uplift at joint 3 and 5 lb uplift at joint 4.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 12) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss 02 Truss Type Jack-Open Truss Qty 4 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 13:04:20 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-thdJj6jWSRMYyDaOUJOO_Xm7hKLZungbqgUhMszCIvf Scale = 1:17.1 W1 T1 B11 2 5 3 4 2x4 4x4 2-4-15 2-4-15 -1-4-0 1-4-0 2-4-15 2-4-15 1-0-0 3-0-2 3-6-0 2-6-5 10.00 12 Plate Offsets (X,Y): [2:0-2-0,0-1-12] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.250.070.00 DEFL Vert(LL)Vert(TL)Horz(TL) in 0.00-0.00-0.01 (loc) 4-54-53 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 9 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 2-4-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)5 =273/0-5-8 (min. 0-1-8)3 =58/Mechanical4 =14/MechanicalMax Horz5 =136(LC 8)Max Uplift 5 =-51(LC 8) 3 =-52(LC 8) 4 =-7(LC 8) Max Grav5 =273(LC 1)3 =58(LC 1)4 =39(LC 4) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES (12) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members. 7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 51 lb uplift at joint 5, 52 lb uplift at joint 3 and 7 lb uplift at joint 4.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 12) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss 03 Truss Type Jack-Closed Truss Qty 2 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 12:04:46 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-W6gBd1Tg7J4fAzLV7iHH8rlGvdU8VNuX_djaw0zCJnV Scale = 1:37.3 W1 T1 W2 B11 2 3 5 4 6 7 8 9 4x6 3x4 3x6 3x4 6-6-0 6-6-0 -1-4-0 1-4-0 6-6-0 6-6-0 1-0-0 6-5-0 6-10-14 10.00 12 LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLLBCDL 30.8 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.61 0.350.00 DEFL Vert(LL) Vert(TL)Horz(TL) in -0.07 -0.170.00 (loc) 4-5 4-54 l/defl >999 >443n/a L/d 240 180n/a PLATES MT20 Weight: 27 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)5 =471/0-5-8 (min. 0-1-8)4 =382/MechanicalMax Horz5 =260(LC 8)Max Uplift5 =-30(LC 8)4 =-155(LC 8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-408/99 NOTES (12) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -1-4-0 to 1-8-0,Interior(1) 1-8-0 to 2-1-5, Exterior(2) 2-1-5 to 6-4-4 zone; cantilever left and rightexposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 30 lb uplift at joint 5 and 155 lb uplift at joint 4.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 12) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss 03A Truss Type Jack-Closed Truss Qty 7 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 12:04:55 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-lrjbW6aJ04CNlMXE85xO?ldnRGYA6R6r3XPYl?zCJnM Scale = 1:37.3 W1 T1 W2 B1 1 2 4 3 5 6 4x6 4x4 3x6 3x4 6-6-0 6-6-0 6-6-0 6-6-0 1-0-0 6-5-0 10.00 12 LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLLBCDL 30.8 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.69 0.350.00 DEFL Vert(LL) Vert(TL)Horz(TL) in -0.07 -0.170.00 (loc) 3-4 3-43 l/defl >999 >434n/a L/d 240 180n/a PLATES MT20 Weight: 25 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)4 =336/Mechanical3 =396/MechanicalMax Horz4 =194(LC 8)Max Uplift3 =-161(LC 8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-4=-275/18 NOTES (11) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever leftand right exposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) All bearings are assumed to be SPF No.2 . 7) Refer to girder(s) for truss to truss connections.8) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 161 lb uplift at joint 3.9) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 11) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard Job Q1103376 Truss 04 Truss Type Jack-Open Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 12:05:19 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-2TAgYKsNMSEzd2NrY7N0zpczpxprkI3NaGDpbczCJn_ Scale: 1"=1' W1 T1 B1 1 2 5 3 42x4 3x4 1-7-11 1-7-11 -1-10-10 1-10-10 1-7-11 1-7-11 1-0-0 1-11-10 2-5-0 1-6-10 7.07 12 LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLLBCDL 30.8 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.34 0.090.00 DEFL Vert(LL) Vert(TL)Horz(TL) in 0.00 0.00-0.01 (loc) 4-5 4-53 l/defl >999 >999n/a L/d 240 180n/a PLATES MT20 Weight: 7 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 1-7-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)5 =355/0-7-6 (min. 0-1-8)4 =-15/Mechanical3 =-23/MechanicalMax Horz5 =97(LC 8)Max Uplift5 =-134(LC 8) 4 =-19(LC 12) 3 =-65(LC 12) Max Grav 5 =355(LC 1)4 =21(LC 4)3 =17(LC 6) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD2-5=-310/169 NOTES (12) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members. 7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 134 lb uplift at joint 5, 19 lb uplift at joint 4 and 65 lb uplift at joint 3.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 12) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss 05 Truss Type Jack-Open Truss Qty 2 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 12:05:50 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-eQYO2wEp3_8ZrpFot8QHkLOJERP4VJkyibDyAJzCJmV Scale = 1:9.6 T1 B1 1 2 5 3 4 2x4 2-1-4 2-1-4 -1-0-0 1-0-0 2-1-4 2-1-4 0-4-12 1-5-9 1-10-13 0-4-11 1-0-14 6.09 12 LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLLBCDL 30.8 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.13 0.030.00 DEFL Vert(LL) Vert(TL)Horz(TL) in -0.00 -0.00-0.00 (loc) 2 2-43 l/defl >999 >999n/a L/d 240 180n/a PLATES MT20 Weight: 7 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2BRACINGTOP CHORD Structural wood sheathing directly applied or 2-1-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)3 =40/Mechanical2 =226/0-5-8 (min. 0-1-8)4 =18/MechanicalMax Horz2 =65(LC 8)Max Uplift3 =-19(LC 9)2 =-81(LC 8) Max Grav 3 =42(LC 2) 2 =227(LC 2) 4 =36(LC 4) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES (12) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Corner(3) zone; cantilever leftand right exposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members.7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 19 lb uplift at joint 3 and 81 lb uplift at joint 2.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss 06 Truss Type Jack-Open Truss Qty 2 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 12:06:22 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-iaTUmsduWpA1hjhyls?n15jnLKKc_nff3ZzfISzCJm? Scale = 1:8.7 T1 B1 1 2 5 3 4 2x4 2-0-2 2-0-2 -1-4-0 1-4-0 2-0-2 2-0-2 0-5-5 1-3-6 1-8-8 0-4-7 0-10-15 5.00 12 LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLLBCDL 30.8 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.19 0.030.00 DEFL Vert(LL) Vert(TL)Horz(TL) in -0.00 -0.00-0.00 (loc) 2 2-43 l/defl >999 >999n/a L/d 240 180n/a PLATES MT20 Weight: 7 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2BRACINGTOP CHORD Structural wood sheathing directly applied or 2-0-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)3 =12/Mechanical2 =273/0-5-8 (min. 0-1-8)4 =17/MechanicalMax Horz2 =58(LC 8)Max Uplift3 =-41(LC 12)2 =-112(LC 8) Max Grav 3 =15(LC 2) 2 =274(LC 2) 4 =34(LC 4) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES (12) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever leftand right exposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members.7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 41 lb uplift at joint 3 and 112 lb uplift at joint 2.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss 07 Truss Type Jack-Closed Truss Qty 4 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 12:06:40 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-A2ZHY0rAHLRTrU3PoeK0muTqjbRUCw6JCNKcwPzCJlj Scale = 1:13.7 T1 W1 B11 2 3 4 5 1.5x4 1.5x4 2x4 4-6-8 4-6-8 -1-4-0 1-4-0 4-6-8 4-6-8 0-5-5 2-4-1 2-9-3 5.00 12 LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLLBCDL 30.8 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.32 0.180.00 DEFL Vert(LL) Vert(TL)Horz(TL) in -0.02 -0.050.00 (loc) 2-4 2-4 l/defl >999 >999n/a L/d 240 180n/a PLATES MT20 Weight: 15 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 4-6-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)4 =188/Mechanical2 =363/0-5-8 (min. 0-1-8)Max Horz2 =97(LC 8)Max Uplift4 =-45(LC 8)2 =-108(LC 8) Max Grav 4 =210(LC 2) 2 =371(LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES (12) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever leftand right exposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members.7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 45 lb uplift at joint 4 and 108 lb uplift at joint 2.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss 10 Truss Type Jack-Open Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 12:07:01 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-35KDyC5LLo4VtjASXYCx6JrRw2d1dQJO18wDAhzCJlO Scale = 1:14.1 W1 T1 B1 1 2 5 3 4 2x4 3x4 1-2-4 1-2-4 -1-4-0 1-4-0 1-2-4 1-2-4 1-8-0 2-4-5 0-4-15 1-11-6 7.00 12 LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLLBCDL 30.8 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.22 0.070.00 DEFL Vert(LL) Vert(TL)Horz(TL) in 0.00 0.00-0.01 (loc) 5 53 l/defl >999 >999n/a L/d 240 180n/a PLATES MT20 Weight: 6 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 1-2-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)5 =260/0-5-8 (min. 0-1-8)4 =-4/Mechanical3 =-31/MechanicalMax Horz5 =69(LC 8)Max Uplift5 =-41(LC 8) 4 =-34(LC 8) 3 =-61(LC 12) Max Grav 5 =260(LC 1)4 =16(LC 4)3 =9(LC 6) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES (12) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever leftand right exposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members.7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 41 lb uplift at joint 5, 34 lb uplift at joint 4 and 61 lb uplift at joint 3.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss 11 Truss Type Jack-Open Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 12:07:16 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-7zku6KHmoPzNA0pKvCzSDUy_G5kkeC0cUz3WBKzCJl9 Scale = 1:17.8 W1 T1 B1 1 2 5 3 4 3x4 4x4 2-6-11 2-6-11 -1-4-0 1-4-0 2-6-11 2-6-11 1-8-0 3-1-14 0-4-15 2-9-0 7.00 12 Plate Offsets (X,Y): [2:0-2-0,0-1-12] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.280.120.00 DEFL Vert(LL)Vert(TL)Horz(TL) in 0.01-0.00-0.02 (loc) 4-54-53 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 10 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 2-6-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)5 =278/0-5-8 (min. 0-1-8)3 =63/Mechanical4 =18/MechanicalMax Horz5 =98(LC 8)Max Uplift 5 =-44(LC 8) 3 =-54(LC 8) 4 =-16(LC 8) Max Grav5 =278(LC 1)3 =63(LC 1)4 =43(LC 4) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES (12) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members. 7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 44 lb uplift at joint 5, 54 lb uplift at joint 3 and 16 lb uplift at joint 4.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 12) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss 12 Truss Type Jack-Closed Truss Qty 4 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 12:07:27 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-I5v2P5PfDnMp_j9S20g19ows_XUvjBlD0BDb4BzCJl_ Scale = 1:21.7 W1 T1 W2 B1 1 2 3 5 4 3x4 4x4 3x4 1.5x4 4-0-0 4-0-0 -1-4-0 1-4-0 4-0-0 4-0-0 1-8-0 4-0-0 7.00 12 Plate Offsets (X,Y): [2:0-2-0,0-1-12] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.310.150.00 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.01-0.02-0.00 (loc) 4-54-54 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 17 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)5 =333/0-5-8 (min. 0-1-8)4 =164/MechanicalMax Horz5 =128(LC 8)Max Uplift5 =-48(LC 8) 4 =-92(LC 8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD2-5=-299/109 NOTES (12) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever leftand right exposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 48 lb uplift at joint 5 and 92 lb uplift at joint 4.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 12) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss 13 Truss Type Jack-Open Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 13:05:46 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-LEqpnWlSBsCLGR9wXMxZTgKo3?hz2gyFc3JFOtzCIuJ Scale: 3/4"=1' W1 T1 B1 1 2 5 6 3 4 3x4 4x4 3-5-2 3-5-2 -1-4-0 1-4-0 3-5-2 3-5-2 1-5-1 2-9-8 0-4-6 2-5-2 4.79 12 Plate Offsets (X,Y): [2:0-2-0,0-1-12] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.370.180.00 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.01-0.01-0.03 (loc) 4-54-53 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 11 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 3-5-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)5 =312/0-5-8 (min. 0-1-8)3 =104/Mechanical4 =31/MechanicalMax Horz5 =80(LC 8)Max Uplift 5 =-77(LC 8) 3 =-54(LC 8) Max Grav 5 =312(LC 1)3 =104(LC 1)4 =60(LC 4) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD2-5=-279/267 NOTES (12) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Corner(3) -1-4-0 to 2-10-15, Exterior(2) 2-10-15 to 3-4-6 zone; cantilever left and right exposed ;C-C for membersand forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members. 7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 77 lb uplift at joint 5 and 54 lb uplift at joint 3.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 12) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss CJ1 Truss Type Diagonal Hip Girder Qty 2 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 13:04:04 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-LcfGNeWUDWLp1mMKYx6eL96J5urI8UxE9BcroozCIvv Scale = 1:41.1 W1 T1 W5 B1W2 W3 W4 1 2 3 4 7 6 5 8 9 10 11 12 1.5x4 3x6 1.5x4 3x4 4x4 3x6 Nailed Nailed Nailed Nailed Nailed Nailed Nailed Nailed 4-6-6 4-6-6 9-0-13 4-6-6 -1-10-10 1-10-10 4-6-6 4-6-6 9-0-13 4-6-6 1-0-0 6-4-2 6-9-8 7.07 12 LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLLBCDL 30.8 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15NOIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.54 0.300.31 DEFL Vert(LL) Vert(TL)Horz(TL) in -0.02 -0.06-0.00 (loc) 5-6 5-65 l/defl >999 >999n/a L/d 240 180n/a PLATES MT20 Weight: 46 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)7 =651/0-7-6 (min. 0-1-8)5 =534/MechanicalMax Horz7 =258(LC 7)Max Uplift7 =-217(LC 7)5 =-307(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-7=-623/230, 2-8=-528/186, 3-8=-389/135BOT CHORD7-11=-258/0, 6-11=-258/0, 6-12=-259/383, 5-12=-259/383WEBS2-6=-147/389, 3-5=-483/326 WEBS2-6=-147/389, 3-5=-483/326 NOTES (14) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members. 7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 217 lb uplift at joint 7 and 307 lb uplift at joint 5.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) "Nailed" indicates 3-10d or 2-12d common wire toe-nails. For more details refer to MiTek's ST-TOENAIL Detail. 13) In the LOAD CASE(S) section, loads applied to the face of the truss are noted asfront (F) or back (B).14) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard1) Snow: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-2=-82, 2-4=-82, 5-7=-20 Concentrated Loads (lb) Vert: 8=48(F=24, B=24) 9=-125(F=-63, B=-63) 11=5(F=3, B=3) 12=-56(F=-28, B=-28) Job Q1103376 Truss CJ2 Truss Type Diagonal Hip Girder Qty 2 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 13:05:00 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-iO2R7nCc1jPslMd4qi6mczQxxS?hGtsT1vApnYzCIv1 Scale = 1:15.6 T1 W3 B1 W1 W2 1 2 3 4 6 5 7 1.5x4 3x4 2x4 3x4 1.5x4 Nailed Nailed Nailed Nailed Special 2-11-15 2-11-15 5-9-5 2-9-6 -1-8-7 1-8-7 2-11-15 2-11-15 5-9-5 2-9-6 0-5-4 2-3-9 2-8-9 3.86 12 LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLLBCDL 30.8 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15NOIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.35 0.090.05 DEFL Vert(LL) Vert(TL)Horz(TL) in -0.00 -0.010.00 (loc) 6 2-65 l/defl >999 >999n/a L/d 240 180n/a PLATES MT20 Weight: 21 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 5-9-5 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)5 =396/Mechanical2 =409/0-6-12 (min. 0-1-8)Max Horz2 =96(LC 5)Max Uplift5 =-81(LC 5)2 =-133(LC 5) Max Grav 5 =416(LC 2) 2 =410(LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES (15) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members. 7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 81 lb uplift at joint 5 and 133 lb uplift at joint 2.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) "Nailed" indicates 3-10d or 2-12d common wire toe-nails. For more details refer to MiTek's ST-TOENAIL Detail. 13) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 210 lb down and 45 lb up at 5-7-9 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.14) In the LOAD CASE(S) section, loads applied to the face of the truss are noted asfront (F) or back (B).15) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard1) Snow: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf) Vert: 1-4=-82, 2-5=-20 Concentrated Loads (lb) Vert: 5=-210(B) 3=106(F=40, B=66) 6=5(F=2, B=3) Job Q1103376 Truss CJ3 Truss Type Diagonal Hip Girder Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 13:05:26 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-xOdGagWwvigAtMd4MAatgSVJextPMcdI?xTBh2zCIud Scale = 1:24.7 W1 T1 W5 B1 W2 W3 W41 2 3 4 7 6 5 8 9 10 11 1.5x4 3x4 1.5x4 3x4 3x4 3x4 Nailed Nailed Nailed Nailed Nailed Nailed 0-0-9 0-0-9 3-5-6 3-4-14 6-10-13 3-5-6 -2-4-5 2-4-5 3-5-6 3-5-6 6-10-13 3-5-6 1-8-0 3-11-4 3.95 12 LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLLBCDL 30.8 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15NOIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.59 0.110.09 DEFL Vert(LL) Vert(TL)Horz(TL) in 0.01 -0.01-0.00 (loc) 6-7 5-65 l/defl >999 >999n/a L/d 240 180n/a PLATES MT20 Weight: 35 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)7 =560/0-8-10 (min. 0-1-8)5 =288/MechanicalMax Horz7 =127(LC 5)Max Uplift7 =-210(LC 5)5 =-135(LC 5) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-7=-538/211, 2-8=-255/76 NOTES (14) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members. 7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 210 lb uplift at joint 7 and 135 lb uplift at joint 5.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) "Nailed" indicates 3-10d or 2-12d common wire toe-nails. For more details refer to MiTek's ST-TOENAIL Detail. 13) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 14) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard1) Snow: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-2=-82, 2-4=-82, 5-7=-20Concentrated Loads (lb)Vert: 6=-11(B) 3=-23(B) 8=27(F) 9=19(F) 10=17(F) 11=-0(F) Job Q1103376 Truss G1 Truss Type Hip Truss Qty 1 Ply 2 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 13:07:23 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-0vBU8hwJLfQaPL3ZiEAJv7rHC6ivGPbWveJtHmzCIso Scale: 1/4"=1' 0-1-15 0-1-15 T1 T2 T1 B1 W1 W2 W3 W4 W5 W4 W5 W4 W3 W2 W1 B1 HW1 HW1 1 2 3 4 5 6 7 8 9 10 1112 19 18 17 16 15 14 13 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 5x6 5x6 6x10 MT20H 4x6 5x6 3x6 2x4 3x4 4x6 3x4 1.5x4 4x9 3x4 3x6 2x4 6x10 MT20H 4x6 THJA26 LUS26 LUS26 LUS26 LUS26 LUS26 LUS26 LUS26 THJA26 3-4-12 3-4-12 6-6-0 3-1-4 11-9-7 5-3-7 17-2-9 5-5-3 22-6-0 5-3-7 25-7-4 3-1-4 29-0-0 3-4-12 -1-4-0 1-4-0 3-4-12 3-4-12 6-6-0 3-1-4 11-9-7 5-3-7 17-2-9 5-5-3 22-6-0 5-3-7 25-7-4 3-1-4 29-0-0 3-4-12 30-4-0 1-4-0 1-0-0 6-3-1 6-5-0 6-10-14 1-0-0 6-3-1 10.00 12 Plate Offsets (X,Y): [2:0-6-15,0-0-2], [5:0-3-0,0-2-1], [8:0-3-0,0-2-1], [11:0-6-15,0-0-2] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15NOIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.710.490.60 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.16-0.260.07 (loc) 15-1715-1711 l/defl >999>999n/a L/d 240180n/a PLATES MT20MT20H Weight: 339 lb FT = 10% GRIP 197/144148/108 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 6 SPF 1650F 1.5EWEBS2 X 4 SPF Stud SLIDER Left 2 X 6 SPF 1650F 1.5E 2-2-10, Right 2 X 6 SPF 1650F 1.5E 2-2-10 BRACING TOP CHORDStructural wood sheathing directly applied or 4-3-10 oc purlins, except 2-0-0 oc purlins (4-4-12 max.): 5-8.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)2 =3819/0-5-8 (min. 0-3-2)11 =3830/0-5-8 (min. 0-3-3) Max Horz 2 =173(LC 6) Max Uplift 2 =-1317(LC 7)11 =-1323(LC 8)Max Grav2 =4019(LC 16)11 =4030(LC 16) Max Grav2 =4019(LC 16) 11 =4030(LC 16) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5056/1681, 3-4=-5032/1698, 4-21=-5379/1857, 5-21=-5311/1870, 5-22=-6040/2023, 6-22=-6045/2023, 6-7=-6028/2022, 7-23=-6034/2023, 8-23=-6029/2023, 8-24=-5330/1881, 9-24=-5398/1867, 9-10=-5043/1706, 10-11=-5067/1689BOT CHORD2-19=-1336/3639, 18-19=-1336/3639, 18-26=-1493/4184, 26-27=-1493/4184, 27-28=-1493/4184, 17-28=-1493/4184, 17-29=-2036/6040, 29-30=-2036/6040, 16-30=-2036/6040, 16-31=-2036/6040, 15-31=-2036/6040, 15-32=-1397/4198, 32-33=-1397/4198, 33-34=-1397/4198, 14-34=-1397/4198, 13-14=-1169/3648, 11-13=-1169/3648 WEBS4-19=-585/246, 4-18=-392/863, 5-18=-507/1151, 5-17=-920/2792,6-17=-897/267, 7-15=-901/227, 8-15=-908/2753, 8-14=-520/1182, 9-14=-397/874, 9-13=-598/252 NOTES (22) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2 X 4 - 1 row at 0-7-0 oc.Bottom chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc.Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc.2) All loads are considered equally applied to all plies, except if noted as front (F) orback (B) face in the LOAD CASE(S) section. Ply to ply connections have been providedto distribute only loads noted as (F) or (B), unless otherwise indicated.3) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 4) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.7) Provide adequate drainage to prevent water ponding.8) All plates are MT20 plates unless otherwise indicated. 9) The solid section of the plate is required to be placed over the splice line at joint(s) 16.10) Plate(s) at joint(s) 16 checked for a plus or minus 1 degree rotation about its center.11) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads. Continued on page 2 Job Q1103376 Truss G1 Truss Type Hip Truss Qty 1 Ply 2 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 13:07:23 2011 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-0vBU8hwJLfQaPL3ZiEAJv7rHC6ivGPbWveJtHmzCIso NOTES (22) 12) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf.13) All bearings are assumed to be SPF No.2 . 14) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 1317 lb uplift at joint 2 and 1323 lb uplift at joint 11.15) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.16) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 17) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 18) Use Simpson Strong-Tie THJA26 (THJA26 on 2 ply, Right Hand Hip) or equivalent at 6-6-6 from the left end to connect truss(es) 03 (1 ply 2 X 4 SPF), CJ1 (1 ply 2 X 4 SPF) to back face of bottom chord. 19) Use Simpson Strong-Tie LUS26 (4-10d Girder, 3-10d Truss, Single Ply Girder) orequivalent spaced at 2-0-0 oc max. starting at 8-6-12 from the left end to 20-5-4 to connecttruss(es) 03 (1 ply 2 X 4 SPF) to back face of bottom chord. 20) Use Simpson Strong-Tie THJA26 (THJA26 on 2 ply, Left Hand Hip) or equivalent at22-5-10 from the left end to connect truss(es) 03A (1 ply 2 X 4 SPF), CJ1 (1 ply 2 X 4SPF) to back face of bottom chord. 21) Fill all nail holes where hanger is in contact with lumber.22) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard 1) Snow: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf)Vert: 1-5=-82, 5-8=-82, 8-12=-82, 2-18=-20, 18-26=-60, 17-26=-20, 17-30=-60,30-34=-20, 14-34=-60, 11-14=-20Concentrated Loads (lb)Vert: 16=-376(B) 18=-836(B) 14=-850(B) 27=-362(B) 28=-376(B) 29=-336(B)31=-376(B) 32=-376(B) 33=-376(B) Job Q1103376 Truss G2 Truss Type Hip Truss Qty 1 Ply 2 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:49:57 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-?ryAvh9nCn1A?fFCCg7HYR8_2ks7NIJz9MIgBYzB?dO Scale = 1:18.6 T1 T2 T1 B1 W1 W2 W1 W2 W1 1 2 3 4 5 8 7 6 9 10 11 12 13 14 15 16 17 18 19 3x8 4x9 4x9 3x8 2x4 3x8 1.5x4 2x4 THJU26-W LUS26 LUS26 THJU26-W LUS26 LUS26 LUS26 LUS26 LUS26 LUS26 3-9-15 3-9-15 6-10-8 3-0-9 9-11-1 3-0-9 13-9-0 3-9-15 3-9-15 3-9-15 6-10-8 3-0-9 9-11-1 3-0-9 13-9-0 3-9-15 0-4-12 2-4-1 0-4-12 2-4-1 6.09 12 Plate Offsets (X,Y): [2:0-6-4,0-2-0], [4:0-6-4,0-2-0] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15NOIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.380.300.28 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.06-0.110.03 (loc) 775 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 108 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 6 SPF 1650F 1.5EWEBS2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 5-9-3 oc purlins, except 2-0-0 oc purlins (5-9-1 max.): 2-4. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)1 =2158/0-5-8 (min. 0-1-12)5 =2247/0-5-8 (min. 0-1-13)Max Horz1 =-26(LC 5)Max Uplift 1 =-92(LC 7) 5 =-144(LC 8) Max Grav 1 =2215(LC 16)5 =2304(LC 16) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD1-2=-3904/176, 2-9=-4500/267, 9-10=-4499/267, 3-10=-4499/267, TOP CHORD1-2=-3904/176, 2-9=-4500/267, 9-10=-4499/267, 3-10=-4499/267, 3-11=-4499/267, 11-12=-4499/267, 4-12=-4500/267, 4-5=-4238/256 BOT CHORD 1-13=-137/3408, 13-14=-137/3408, 8-14=-137/3408, 8-15=-132/3478, 15-16=-132/3478, 7-16=-132/3478, 7-17=-184/3799, 17-18=-184/3799, 6-18=-184/3799, 6-19=-182/3702, 5-19=-182/3702WEBS2-8=0/940, 2-7=-163/1213, 3-7=-439/108, 4-7=-72/831, 4-6=-26/1306 NOTES (19)1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc. Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) orback (B) face in the LOAD CASE(S) section. Ply to ply connections have been providedto distribute only loads noted as (F) or (B), unless otherwise indicated.3) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; LumberDOL=1.33 plate grip DOL=1.33 4) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-05) Unbalanced snow loads have been considered for this design. 6) Provide adequate drainage to prevent water ponding.7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.8) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.9) All bearings are assumed to be SPF No.2 . 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 5=144. 11) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 13) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened totruss TC w/ 2-10d nails.14) Use Simpson Strong-Tie THJU26-W (DBL & DBL RC 2-PLY) or equivalent spacedat 6-0-0 oc max. starting at 3-10-11 from the left end to 9-10-11 to connect truss(es) 07(1 ply 2 X 4 SPF), NOT SPEC'D (1 ply 2 X 4 SPF) to front face of bottom chord. 15) Use Simpson Strong-Tie LUS26 (4-10d Girder, 3-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 5-10-11 from the left end to 7-10-11 to connect truss(es) 07 (1 ply 2 X 4 SPF) to front face of bottom chord. Continued on page 2 Job Q1103376 Truss G2 Truss Type Hip Truss Qty 1 Ply 2 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:49:57 2011 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-?ryAvh9nCn1A?fFCCg7HYR8_2ks7NIJz9MIgBYzB?dO NOTES (19) 16) Use Simpson Strong-Tie LUS26 (4-10d Girder, 3-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 1-6-12 from the left end to 11-5-4 to connect truss(es) 03A (1 ply 2 X 4 SPF) to back face of bottom chord. 17) Fill all nail holes where hanger is in contact with lumber.18) WARNING: The following hangers are manually applied but fail due to geometricconsiderations: THJU26-W on front face at 3-10-11 from the left end, THJU26-W on frontface at 9-10-11 from the left end.19) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard 1) Snow: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-82, 2-4=-82, 4-5=-82, 1-5=-20 Concentrated Loads (lb) Vert: 8=-190(F) 6=-902(F=-586, B=-316) 13=-316(B) 14=-316(B) 15=-316(B) 16=-190(F)17=-316(B) 18=-190(F) 19=-316(B) Job Q1103376 Truss G3 Truss Type Hip Truss Qty 1 Ply 2 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:48:46 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-aBAK?PIFwz4F_lKYYGLdAShu26e3E3tWqpbPB9zB?eV Scale = 1:76.8 0-1-15 0-1-15 T1 T2 T3 B2 W1 W2 W3 W4 W5 W6 W5 W8W7 BL1 HW1 B1 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 17 1819 20 21 22 23 24 2526 27 28 296x9 4x4 4x4 6x6 5x6 6x9 3x8 3x6 3x6 8x9 4x9 4x6 7x8 10x12 3x4 3x4 3x4 5-0-13 5-0-13 9-10-3 4-9-5 14-7-8 4-9-5 15-10-8 1-3-0 19-8-0 3-9-8 5-0-13 5-0-13 9-10-3 4-9-5 14-7-8 4-9-5 15-10-8 1-3-0 19-8-0 3-9-8 1-0-0 13-0-5 13-2-4 10-0-5 0-9-8 13-0-5 10.00 12 Plate Offsets (X,Y): [1:0-2-12,0-2-8], [7:0-6-8,0-0-8], [8:0-5-4,0-1-8], [9:0-6-0,0-5-12], [12:0-3-8,0-6-0] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15NOIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.240.270.78 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.12-0.210.02 (loc) 10-1210-1215 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 429 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 6 SPF 1650F 1.5EBOT CHORD 2 X 8 SYP DSSWEBS2 X 4 SPF No.2 *Except* W1,W2,W3: 2 X 4 SPF Stud OTHERS 2 X 4 SPF No.2 SLIDER Left 2 X 4 SPF No.2 3-1-15 BRACING TOP CHORDStructural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and2-0-0 oc purlins (6-0-0 max.): 5-6.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 4-10 REACTIONS (lb/size) 1 =3532/0-5-8 (min. 0-3-2) 15 =5952/0-3-8 (req. 0-5-1) Max Horz1 =329(LC 6)Max Uplift1 =-542(LC 7)15 =-1186(LC 8) Max Uplift1 =-542(LC 7) 15 =-1186(LC 8) Max Grav 1 =3953(LC 17) 15 =6456(LC 17) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD1-2=-5254/710, 2-16=-5122/722, 3-16=-5075/730, 3-17=-4172/636, 4-17=-4056/657, 4-18=-2424/446, 18-19=-2131/448, 5-19=-2065/454, 5-20=-1485/366, 6-20=-1483/366, 6-7=-2061/410, 8-14=-228/1151, 7-14=-228/1151BOT CHORD 1-21=-749/3742, 13-21=-749/3742, 13-22=-749/3743, 22-23=-749/3743, 12-23=-749/3743, 11-12=-580/3116, 11-24=-580/3116, 24-25=-580/3116, 10-25=-580/3116, 10-26=-302/1641, 9-26=-302/1641WEBS3-13=-123/992, 3-12=-872/235, 4-12=-568/3036, 4-10=-3050/595,5-10=-482/2511, 5-9=-1369/290, 6-9=-202/879, 7-9=-762/4147 NOTES (17) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc, 2 X 4 - 1 row at 0-9-0 oc.Bottom chords connected as follows: 2 X 8 - 4 rows at 0-2-0 oc.Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc.2) All loads are considered equally applied to all plies, except if noted as front (F) orback (B) face in the LOAD CASE(S) section. Ply to ply connections have been providedto distribute only loads noted as (F) or (B), unless otherwise indicated.3) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 4) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0 5) Unbalanced snow loads have been considered for this design. 6) Provide adequate drainage to prevent water ponding.7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.8) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.9) WARNING: Required bearing size at joint(s) 15 greater than input bearing size.10) All bearings are assumed to be SPF No.2 . 11) Bearing at joint(s) 15 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.Continued on page 2 Job Q1103376 Truss G3 Truss Type Hip Truss Qty 1 Ply 2 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:48:46 2011 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-aBAK?PIFwz4F_lKYYGLdAShu26e3E3tWqpbPB9zB?eV NOTES (17) 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=542, 15=1186. 13) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.14) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 15) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to trussTC w/ 2-10d nails.16) Hanger(s) or other connection device(s) shall be provided sufficient to supportconcentrated load(s) 486 lb down and 71 lb up at 4-0-12, 503 lb down and 74 lb up at 6-0-12, 797 lb down and 169 lb up at 8-0-12, 797 lb down and 169 lb up at 10-0-12, 797 lb down and 169 lb up at 12-0-12, 797 lb down and 169 lb up at 14-0-12, 797 lb down and 169 lb up at 15-3-0, 801 lb down and 169 lb up at 16-5-4, and 801 lb down and 169 lb up at 18-5-4, and 817 lb down and 159 lb up at 19-2-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 17) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard1) Snow: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-5=-82, 5-6=-82, 6-7=-82, 1-12=-20, 12-24=-60, 24-28=-20, 8-28=-60Concentrated Loads (lb)Vert: 8=-817(F) 12=-797(F) 21=-486(F) 22=-503(F) 23=-797(F) 24=-797(F) 25=-797(F) 26=-797(F) 27=-801(F) 29=-801(F) Job Q1103376 Truss H1 Truss Type Hip Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:48:31 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-WJmfsH6qSMBNgSggAca63IaAu3UODMbJO_T69XzB?ek Scale = 1:46.5 0-1-15 0-1-15 T1 T2 T1 B1 W3 W4 W5 W6 W5 W4 W3 W1 W2 W1 W2 B11 2 3 4 5 6 7 8 9 14 13 12 11 10 15 16 17 18 19 20 21 22 23 24 5x6 5x6 3x4 4x4 5x8 1.5x4 3x4 4x4 3x4 3x8 3x8 3x4 8-6-0 8-6-0 14-6-0 6-0-0 20-6-0 6-0-0 29-0-0 8-6-0 -1-4-0 1-4-0 4-4-12 4-4-12 8-6-0 4-1-4 14-6-0 6-0-0 20-6-0 6-0-0 24-7-4 4-1-4 29-0-0 4-4-12 30-4-0 1-4-0 1-0-0 7-11-1 8-1-0 8-6-14 1-0-0 7-11-1 10.00 12 Plate Offsets (X,Y): [4:0-3-0,0-2-1], [6:0-3-0,0-2-1], [12:0-4-0,0-3-0] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.880.410.50 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.12-0.260.07 (loc) 11-1213-1410 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 151 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5EBOT CHORD 2 X 4 SPF 1650F 1.5EWEBS2 X 4 SPF Stud *Except* W5: 2 X 4 SPF No.2, W1: 2 X 6 SPF 1650F 1.5EBRACING TOP CHORD Structural wood sheathing directly applied or 4-9-8 oc purlins, except end verticals, and 2-0-0 oc purlins (3-8-6 max.): 4-6.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 5-12, 3-14, 7-10 REACTIONS (lb/size)14 =1698/0-5-8 (min. 0-3-5)10 =1698/0-5-8 (min. 0-3-5) Max Horz 14 =-202(LC 6) Max Uplift 14 =-241(LC 8)10 =-241(LC 9)Max Grav14 =2101(LC 18)10 =2101(LC 18) Max Grav14 =2101(LC 18) 10 =2101(LC 18) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-15=-474/89, 3-15=-280/109, 3-16=-1969/334, 4-16=-1887/348, 4-17=-1995/374, 17-18=-1997/374, 5-18=-2000/373, 5-19=-2000/373, 19-20=-1997/374, 6-20=-1995/374, 6-21=-1887/348, 7-21=-1969/334, 7-22=-280/109, 8-22=-474/89, 2-14=-725/194, 8-10=-725/194BOT CHORD13-14=-295/1452, 13-23=-231/1506, 12-23=-231/1506, 12-24=-130/1506, 11-24=-130/1506, 10-11=-103/1452WEBS 3-13=-265/160, 4-13=-36/433, 4-12=-215/795, 5-12=-1080/261, 6-12=-215/795, 6-11=-36/433, 7-11=-265/160, 3-14=-1800/252, 7-10=-1800/252 NOTES (13) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -1-4-0 to 1-8-0,Interior(1) 1-8-0 to 4-3-1, Exterior(2) 4-3-1 to 8-6-0, Interior(1) 12-8-15 to 16-3-1,Exterior(2) 20-6-0 to 30-4-0 zone; cantilever left and right exposed ;C-C for membersand forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-03) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 30.8 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.8) All bearings are assumed to be SPF No.2 . 9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 14=241, 10=241.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. Continued on page 2 Job Q1103376 Truss H1 Truss Type Hip Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:48:31 2011 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-WJmfsH6qSMBNgSggAca63IaAu3UODMbJO_T69XzB?ek NOTES (13) 12) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 13) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss H2 Truss Type Hip Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:48:25 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-h9OObE24tWREyXDWpLTip1K9NeMRpYlQ?20oytzB?eq Scale = 1:58.9 0-1-15 0-1-15 0-1-15 0-1-15 T1 T2 T3 T4 T5B1 W3 W4 W5 W6 W5 W7 W8 W9 W10 W1 W2 W1 B2 W11 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 11 18 19 20 21 22 23 24 25 26 27 28 29 30 31 8x9 6x6 5x8 MT18H 5x8 3x4 4x6 3x6 5x6 3x4 3x8 4x6 5x8 5x9 4x6 3x4 Nailed Nailed 5-4-12 5-4-12 10-6-0 5-1-4 18-6-0 8-0-0 27-9-0 9-3-0 29-3-0 1-6-0 30-6-0 1-3-0 -1-4-0 1-4-0 5-4-12 5-4-12 10-6-0 5-1-4 18-6-0 8-0-0 23-1-8 4-7-8 27-9-0 4-7-8 29-3-0 1-6-0 30-6-0 1-3-0 31-10-0 1-4-0 1-0-0 1-10-9 9-7-1 9-9-0 10-2-14 1-0-0 9-7-1 10.00 12 Plate Offsets (X,Y): [4:0-6-11,Edge], [5:0-3-11,Edge], [7:0-4-0,0-2-0], [8:0-4-0,0-2-2], [12:0-1-8,0-1-8] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.820.760.84 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.26-0.510.08 (loc) 12-1312-1311 l/defl >999>710n/a L/d 240180n/a PLATES MT20MT18H Weight: 164 lb FT = 10% GRIP 197/144197/144 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5E *Except* T2: 2 X 6 SPF 1650F 1.5EBOT CHORD 2 X 4 SPF 1650F 1.5E WEBS 2 X 4 SPF Stud *Except* W5,W6,W10: 2 X 4 SPF No.2, W1: 2 X 6 SPF 1650F 1.5E BRACING TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and2-0-0 oc purlins (4-0-7 max.): 4-5, 7-8.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 16-17.WEBS1 Row at midpt 4-13 REACTIONS (lb/size) 17 =1829/0-5-8 (min. 0-3-13) 11 =1772/0-5-8 (min. 0-3-10) Max Horz 17 =251(LC 6)Max Uplift17 =-248(LC 7)11 =-239(LC 8)Max Grav17 =2426(LC 21) Max Grav11 =2314(LC 21) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-19=-2645/198, 3-19=-2202/212, 3-20=-2216/231, 20-21=-2042/232, 4-21=-1954/255, 4-22=-1583/230, 22-23=-1583/230, 5-23=-1583/230, 5-6=-2306/253, 6-24=-3524/360, 24-25=-3661/350, 25-26=-3746/346, 7-26=-3873/343, 7-8=-3116/233, 2-17=-2362/273, 9-11=-533/138BOT CHORD16-17=-278/318, 16-27=-258/1844, 15-27=-258/1844, 14-15=-186/1506, 14-28=-186/1506, 13-28=-186/1506, 13-29=-76/2112, 29-30=-76/2112, 12-30=-76/2112, 12-31=-33/1112, 11-31=-33/1112 WEBS 3-15=-474/162, 4-15=-50/643, 4-13=-145/287, 5-13=-45/841, 6-13=-806/190, 6-12=-134/1197, 7-12=-2861/339, 8-12=-208/2881, 2-16=-62/1547, 8-11=-2087/96 NOTES (16) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-03) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.5) Provide adequate drainage to prevent water ponding. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.9) All bearings are assumed to be SPF No.2 . 10) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 17=248, 11=239.11) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. Continued on page 2 Job Q1103376 Truss H2 Truss Type Hip Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:48:26 2011 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-9Lymoa3ieqZ5agoiN3_xMEsK72ifY??aEilLUKzB?ep NOTES (16) 13) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 14) "Nailed" indicates 3-10d or 2-12d common wire toe-nails. For more details refer toMiTek's ST-TOENAIL Detail. 15) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front(F) or back (B).16) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard1) Snow: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-82, 2-4=-82, 4-5=-82, 5-7=-82, 7-8=-82, 8-9=-82, 9-10=-82, 16-17=-20, 16-27=-60, 15-27=-20, 15-28=-60, 28-29=-20, 29-30=-60, 11-30=-20 Concentrated Loads (lb) Vert: 8=25(B) 31=20(B) Job Q1103376 Truss H3 Truss Type Hip Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:48:16 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-SQM_i9xQ_lIVN81noypby7SaX0L?CUV6x9Kq7vzB?ez Scale: 3/16"=1' 0-1-15 0-1-15 0-1-15 0-1-15 T1 T2 T3 T4 T5 B1 W3 W4 W5 W6 W5 W7 W8 W9 W10 W11 W12 W1 W2 W1 W13B21 2 3 4 5 6 7 8 9 10 19 18 17 16 15 14 13 12 11 20 21 22 23 24 25 26 27 28 29 30 31 32 5x6 5x6 8x9 5x8 3x4 3x4 3x6 5x6 4x4 3x8 3x6 3x4 6x6 6x6 4x9 3x4 4x9 6-4-12 6-4-12 12-6-0 6-1-4 16-6-0 4-0-0 21-1-8 4-7-8 25-9-0 4-7-8 27-3-0 1-6-0 30-6-0 3-3-0 -1-4-0 1-4-0 6-4-12 6-4-12 12-6-0 6-1-4 16-6-0 4-0-0 21-1-8 4-7-8 25-9-0 4-7-8 27-3-0 1-6-0 30-6-0 3-3-0 31-10-0 1-4-0 1-0-03-6-9 11-3-1 11-5-0 11-10-14 1-0-0 11-3-1 10.00 12 Plate Offsets (X,Y): [2:0-3-8,0-2-0], [4:0-3-0,0-2-1], [5:0-3-0,0-2-1], [7:0-3-8,0-2-7], [8:0-4-0,0-1-4] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.950.460.84 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.14-0.230.08 (loc) 14-1517-1811 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 183 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5EBOT CHORD 2 X 4 SPF 1650F 1.5EWEBS2 X 4 SPF Stud *Except* W5,W6: 2 X 4 SPF No.2, W1: 2 X 6 SPF 1650F 1.5EBRACING TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-3-1 max.): 4-5, 7-8.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 11-12.WEBS1 Row at midpt 3-17, 4-15, 6-15 REACTIONS (lb/size)19 =1807/0-5-8 (min. 0-3-15) 11 =1777/0-5-8 (min. 0-4-0) Max Horz 19 =-297(LC 6) Max Uplift19 =-248(LC 8)11 =-251(LC 9)Max Grav19 =2491(LC 22) Max Grav11 =2539(LC 22) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-20=-2905/269, 20-21=-2849/273, 21-22=-2422/296, 3-22=-2363/298, 3-23=-2317/334, 23-24=-1991/349, 4-24=-1885/363, 4-5=-1550/351, 5-25=-1947/391, 25-26=-2247/380, 6-26=-2276/366, 6-27=-2526/356, 27-28=-2693/344, 28-29=-2743/341, 7-29=-2926/338, 7-8=-2702/331, 8-9=-2503/272, 2-19=-2431/331, 9-11=-2497/330BOT CHORD18-19=-341/446, 18-30=-216/2046, 17-30=-216/2046, 16-17=-116/1527, 16-31=-116/1527, 15-31=-116/1527, 15-32=-53/2094, 14-32=-53/2094, 13-14=-162/2626, 12-13=-84/1829 WEBS 3-17=-723/185, 4-17=-80/710, 4-15=-193/263, 5-15=-132/940, 6-15=-1009/212, 6-14=-36/541, 7-14=-654/143, 7-13=-1721/213, 8-13=-197/1961, 8-12=-476/58, 2-18=-57/1615, 9-12=-140/1829 NOTES (15) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -1-4-0 to 1-8-10,Interior(1) 1-8-10 to 8-2-4, Exterior(2) 8-2-4 to 20-9-12, Interior(1) 20-9-12 to 25-9-0,Exterior(2) 27-3-0 to 31-10-0 zone; cantilever left and right exposed ;C-C for membersand forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-03) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 30.8 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) The solid section of the plate is required to be placed over the splice line at joint(s) 4. 7) Plate(s) at joint(s) 4 checked for a plus or minus 1 degree rotation about its center.8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.9) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.10) All bearings are assumed to be SPF No.2 . 11) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 19=248, 11=251. 12) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.Continued on page 2 Job Q1103376 Truss H3 Truss Type Hip Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:48:16 2011 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-SQM_i9xQ_lIVN81noypby7SaX0L?CUV6x9Kq7vzB?ez NOTES (15) 13) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 14) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to trussTC w/ 2-10d nails.15) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss H4G Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:48:10 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-dG_jS5sfPvYMfDZeRiiBisCd7bK7onKDZDtVxFzB?f3 Scale = 1:79.3 0-1-12 0-1-12 T1 T2 T3 T4 B1 B3 B4 W3 W4 W5 W4 W3 W6 W7 W8 W10 W9 W11 W13 W1 W2 W15 W14 B212 3 4 5 6 7 8 9 10 11 21 20 19 18 17 16 15 14 13 12 22 23 24 25 26 27 28 29 30 31 32 4x4 5x6 6x9 3x4 5x6 3x4 2x4 3x6 4x4 5x8 3x6 3x4 5x6 8x9 4x9 3x4 3x4 6x6 4x4 LUS26 LUS26 LUS26 THJU26-W 6-8-15 6-8-15 11-1-2 4-4-3 15-5-5 4-4-3 19-9-7 4-4-3 22-2-4 2-4-13 27-7-0 5-4-12 30-8-0 3-1-0 34-0-8 3-4-8 -1-4-0 1-4-0 6-8-15 6-8-15 11-1-2 4-4-3 15-5-5 4-4-3 19-9-7 4-4-3 22-2-4 2-4-13 27-7-0 5-4-12 30-8-0 3-1-0 34-0-8 3-4-8 35-4-8 1-4-0 1-0-0 2-10-4 10-2-15 11-2-15 1-5-1 1-0-0 3-10-4 10.00 12 4.79 12 Plate Offsets (X,Y): [8:0-2-8,Edge], [16:0-7-4,0-5-0], [19:0-3-4,0-3-0] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15NOIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.690.370.82 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.05-0.140.02 (loc) 20-2120-2112 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 187 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5EBOT CHORD 2 X 4 SPF No.2 *Except* B4: 2 X 6 SPF 1650F 1.5E WEBS 2 X 4 SPF Stud *Except* W5,W1,W15: 2 X 4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 5-5-9 oc purlins, except end verticals, and2-0-0 oc purlins (6-0-0 max.): 6-8.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 16-17,12-13.WEBS1 Row at midpt 8-16 REACTIONS (lb/size) 21 =1245/0-5-8 (min. 0-2-2) 12 =807/0-5-8 (min. 0-1-10) 16 =2599/0-5-8 (min. 0-4-4) Max Horz21 =-285(LC 5)Max Uplift21 =-204(LC 7)12 =-339(LC 6) Max Uplift16 =-587(LC 7) Max Grav 21 =1344(LC 2) 12 =1023(LC 19) 16 =2715(LC 19) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-22=-1439/138, 3-22=-1117/156, 3-23=-1059/203, 4-23=-822/224, 4-24=-851/210, 5-24=-1093/189, 5-6=-1440/148, 6-7=-571/65, 7-25=-34/727, 25-26=-34/729, 26-27=-34/729, 8-27=-34/730, 8-9=-870/466, 9-28=-874/353, 10-28=-949/344, 2-21=-1280/235, 10-12=-962/341BOT CHORD 20-21=-231/369, 20-29=-33/973, 19-29=-33/973, 19-30=0/968, 18-30=0/968, 17-18=0/643, 16-17=-740/135, 7-16=-1576/187, 13-14=-264/812 WEBS3-19=-609/192, 4-19=-210/747, 5-19=-544/137, 6-18=0/379, 6-17=-1308/134, 7-17=-141/1914, 14-16=-303/762, 8-16=-1549/443, 8-14=-236/627, 9-13=-280/160, 2-20=-38/667, 10-13=-281/818 WEBS3-19=-609/192, 4-19=-210/747, 5-19=-544/137, 6-18=0/379, 6-17=-1308/134, 7-17=-141/1914, 14-16=-303/762, 8-16=-1549/443, 8-14=-236/627, 9-13=-280/160, 2-20=-38/667, 10-13=-281/818 NOTES (20)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-03) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) The solid section of the plate is required to be placed over the splice line at joint(s) 8. 7) Plate(s) at joint(s) 8 checked for a plus or minus 1 degree rotation about its center. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.9) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.10) All bearings are assumed to be SPF No.2 . Continued on page 2 Job Q1103376 Truss H4G Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:48:11 2011 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-5SY5fRtIADgDHN8q?PDQF4lot?gMXEaMntd3ThzB?f2 NOTES (20) 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 21=204, 12=339, 16=587. 12) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.13) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 14) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to trussTC w/ 2-10d nails.15) Use Simpson Strong-Tie LUS26 (4-10d Girder, 3-10d Truss, Single Ply Girder) orequivalent spaced at 2-0-0 oc max. starting at 22-4-0 from the left end to 25-6-4 to connecttruss(es) 12 (1 ply 2 X 4 SPF) to back face of bottom chord. 16) Use Simpson Strong-Tie THJU26-W (DBL & DBL RC 2-PLY) or equivalent at 27-6-10 from the left end to connect truss(es) 12 (1 ply 2 X 4 SPF), CJ3 (1 ply 2 X 4 SPF) to back face of bottom chord, skewed 0.0 deg.to the right, sloping 0.0 deg. down. Blocking required above the heel of the carried truss to reach full uplift capacity. (See MiTek's "Hanger Blocking Detail" for blocking installation.) 17) Fill all nail holes where hanger is in contact with lumber.18) WARNING: The following hangers are manually applied but fail due to geometricconsiderations: LUS26 on back face at 22-4-0 from the left end, THJU26-W on back faceat 27-6-10 from the left end.19) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front(F) or back (B).20) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard 1) Snow: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf)Vert: 1-2=-82, 2-4=-82, 4-6=-82, 6-8=-82, 8-10=-82, 10-11=-82, 20-21=-20, 20-29=-60,29-30=-20, 18-30=-60, 16-18=-20, 12-15=-20Concentrated Loads (lb)Vert: 16=-144(B) 14=-412(B) 31=-144(B) 32=-144(B) Job Q1103376 Truss H5 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:47:01 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-9_KezV1Nfis8tcoNuiz0PJrsdnms7Z03h_gM0lzB?g8 Scale = 1:66.4 0-1-15 0-1-15 T1 T2 T3 T4 B1 B2 B3 W3 W4 W5 W6 W7 W8 W9 W11 W10 W12 W13 W14W1 W2 W16 W15 B1 1 2 3 4 5 6 7 8 9 10 19 18 17 16 15 14 13 12 11 20 21 22 23 24 25 26 27 28 29 30 31 32 4x6 4x6 5x6 6x9 5x6 1.5x4 1.5x4 3x6 4x4 5x8 4x4 5x9 8x9 3x8 3x4 4x4 3x4 3x6 5-8-5 5-8-5 11-1-2 5-4-13 18-4-10 7-3-8 22-2-4 3-9-10 24-7-15 2-5-11 29-2-8 4-6-8 34-0-8 4-10-0 5-8-5 5-8-5 11-1-2 5-4-13 14-8-14 3-7-12 18-4-10 3-7-12 22-2-4 3-9-10 24-7-15 2-5-11 29-2-8 4-6-8 34-0-8 4-10-0 35-4-8 1-4-0 1-0-0 4-0-1 10-2-15 11-2-15 1-5-1 1-0-0 5-0-1 10.00 12 4.79 12 Plate Offsets (X,Y): [1:0-2-12,0-1-8], [5:0-3-0,0-1-4], [7:0-2-8,Edge], [15:0-7-4,0-5-0], [17:0-4-0,0-3-0] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.560.440.84 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.14-0.260.01 (loc) 16-1716-1715 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 178 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5EBOT CHORD 2 X 4 SPF 1650F 1.5E *Except* B2: 2 X 4 SPF No.2 WEBS 2 X 4 SPF Stud *Except* W5,W1,W16: 2 X 4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 5-7-15 oc purlins, except end verticals, and2-0-0 oc purlins (6-0-0 max.): 5-7.BOT CHORDRigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS (lb/size)11 =485/0-5-8 (min. 0-1-8)15 =2154/0-5-8 (min. 0-3-10)19 =1094/0-5-8 (min. 0-1-14) Max Horz 19 =-308(LC 6) Max Uplift 11 =-170(LC 7)15 =-210(LC 8)19 =-128(LC 8)Max Grav11 =781(LC 20) Max Grav15 =2322(LC 20) 19 =1209(LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-20=-1443/167, 2-20=-1183/184, 2-21=-1094/206, 21-22=-908/214, 22-23=-817/220, 3-23=-787/232, 3-24=-772/249,24-25=-792/239, 4-25=-991/231, 4-5=-931/178, 5-26=-567/80, 6-26=-568/79, 6-7=-76/828, 7-27=-8/308, 27-28=-10/272, 8-28=-58/252, 8-29=-444/127, 9-29=-621/119, 1-19=-1150/172, 9-11=-735/189BOT CHORD18-19=-115/336, 18-30=-59/1022, 17-30=-59/1022, 17-31=0/773, 31-32=0/773, 16-32=0/773, 15-16=-832/246, 6-15=-1496/244, 12-13=-46/489 WEBS 2-17=-558/204, 3-17=-183/686, 4-17=-351/148, 4-16=-363/31, 5-16=-798/185, 6-16=-215/1948, 13-15=-260/131, 7-15=-1177/226, 7-13=-90/570, 8-13=-745/129, 1-18=0/870, 9-12=-53/430 NOTES (13) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-1-12 to 3-6-10,Interior(1) 3-6-10 to 7-8-4, Exterior(2) 7-8-4 to 11-1-2, Interior(1) 14-8-14 to 18-4-10,Exterior(2) 21-3-2 to 24-7-15, Interior(1) 28-0-13 to 31-11-10 zone; cantilever left andright exposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-03) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 30.8 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.8) All bearings are assumed to be SPF No.2 . 9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 11=170, 15=210, 19=128.10) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. Continued on page 2 Job Q1103376 Truss H5 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:47:01 2011 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-9_KezV1Nfis8tcoNuiz0PJrsdnms7Z03h_gM0lzB?g8 NOTES (13) 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 12) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to trussTC w/ 2-10d nails.13) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss H6 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:46:57 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-GD4778_tbULjP?Ucftu4FTg4yAPZBkdTmMi8t_zB?gC Scale = 1:66.6 0-1-12 0-1-12T1 T2 T3 T4 B2 B3 B4 W1 W2 W3 W4 W5 W6 W7 W9 W8 W10 W12 W11 B1 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 18 19 20 21 22 23 24 25 26 27 28 29 303x8 4x6 5x9 6x9 1.5x4 2x4 2x4 3x6 1.5x4 5x8 4x6 4x9 6x9 3x4 5x6 6-2-11 6-2-11 11-11-10 5-8-15 17-10-6 5-10-12 22-10-0 4-11-10 23-0-12 0-2-12 28-10-2 5-9-6 34-11-0 6-0-14 6-2-11 6-2-11 11-11-10 5-8-15 17-10-6 5-10-12 22-7-6 4-9-1 23-0-12 0-5-6 28-10-2 5-9-6 34-11-0 6-0-14 36-3-0 1-4-0 0-3-4 5-2-4 10-2-15 11-2-15 1-5-1 1-0-0 6-2-4 10.00 12 4.79 12 Plate Offsets (X,Y): [1:0-7-0,0-0-12], [4:0-2-8,0-2-8], [5:0-4-10,Edge], [8:0-2-12,0-2-0], [13:0-3-8,0-2-12], [15:0-4-0,0-3-0] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.920.400.93 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.07-0.150.03 (loc) 1-161-1613 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 171 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5E *Except* T3: 2 X 4 SPF 2100F 1.8EBOT CHORD 2 X 4 SPF 1650F 1.5E *Except* B3: 2 X 4 SPF Stud WEBS 2 X 4 SPF Stud *Except* W3,W12: 2 X 4 SPF No.2 BRACING TOP CHORDStructural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins(6-0-0 max.): 4-5.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 13-14,11-12. REACTIONS (lb/size)1 =1136/0-4-0 (min. 0-1-15) 10 =441/0-5-8 (min. 0-1-8) 13 =2234/0-5-8 (min. 0-3-15) Max Horz 1 =-316(LC 6)Max Uplift1 =-135(LC 8)10 =-164(LC 7)13 =-218(LC 7) Max Uplift1 =-135(LC 8) 10 =-164(LC 7) 13 =-218(LC 7) Max Grav 1 =1240(LC 2) 10 =756(LC 20)13 =2512(LC 20) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD1-17=-1688/196, 2-17=-1401/214, 2-18=-1090/212, 18-19=-1067/215, 19-20=-900/216, 20-21=-812/229, 3-21=-729/242, 3-22=-769/231, 4-22=-1029/214, 4-23=-601/163, 5-23=-601/163, 5-6=0/570, 6-24=-44/838, 24-25=-46/709, 25-26=-47/700, 7-26=-56/597, 7-27=-358/122, 8-27=-457/101, 8-10=-701/189 BOT CHORD 1-28=-81/1196, 16-28=-81/1196, 16-29=-81/1196, 15-29=-81/1196, 15-30=0/626, 14-30=0/626, 13-14=-544/188, 6-13=-944/199WEBS2-16=0/273, 2-15=-766/217, 3-15=-137/560, 4-14=-1034/214, WEBS2-16=0/273, 2-15=-766/217, 3-15=-137/560, 4-14=-1034/214, 5-14=-210/1639, 5-13=-1382/140, 11-13=-64/335, 7-13=-1049/167, 7-11=0/253 NOTES (13) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-2-0 to 3-7-14,Interior(1) 3-7-14 to 8-5-12, Exterior(2) 8-5-12 to 11-11-10, Interior(1) 15-5-8 to 17-10-6,Exterior(2) 19-1-8 to 22-7-6, Interior(1) 26-1-5 to 32-9-2 zone; cantilever left and rightexposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-03) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 30.8 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.8) All bearings are assumed to be SPF No.2 . Continued on page 2 Job Q1103376 Truss H6 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:46:57 2011 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-GD4778_tbULjP?Ucftu4FTg4yAPZBkdTmMi8t_zB?gC NOTES (13) 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=135, 10=164, 13=218. 10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to trussTC w/ 2-10d nails.13) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard Job Q1103376 Truss H7 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:46:53 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-OSrcHmxMXFrHwOBrQ1p85dWUNZxwFwburkkxkDzB?gG Scale = 1:69.6 0-1-12 0-1-12 T1 T2 T3 T4 B2 B3 B4 W1 W2 W3 W4 W5 W6 W7 W8 W10 W9 W11 W13 W12 B1 1 2 3 4 5 6 7 8 9 17 16 15 14 13 12 11 10 18 19 20 21 22 23 24 25 26 27 28 29 30 313x8 4x6 4x9 4x4 5x6 2x4 2x4 3x6 1.5x4 5x8 1.5x4 5x8 4x9 8x9 3x4 5x6 6-2-11 6-2-11 11-11-10 5-8-15 16-5-9 4-5-15 19-8-5 3-2-12 22-10-0 3-1-11 23-0-12 0-2-12 28-10-2 5-9-6 34-11-0 6-0-14 6-2-11 6-2-11 11-11-10 5-8-15 16-5-9 4-5-15 19-8-5 3-2-12 23-0-12 3-4-7 28-10-2 5-9-6 34-11-0 6-0-14 36-3-0 1-4-0 0-3-4 6-4-4 10-2-15 11-2-15 1-5-1 1-0-0 7-4-4 10.00 12 4.79 12 Plate Offsets (X,Y): [1:0-7-0,0-0-12], [4:0-4-0,0-2-4], [8:0-3-0,0-1-12], [13:0-7-4,0-5-0], [16:0-4-0,0-3-0] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.640.830.93 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.07-0.150.03 (loc) 1-171-1713 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 180 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5EBOT CHORD 2 X 4 SPF 1650F 1.5E *Except* B3: 2 X 4 SPF No.2 WEBS 2 X 4 SPF Stud *Except* W3,W13: 2 X 4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 4-11-13 oc purlins, except end verticals, and2-0-0 oc purlins (6-0-0 max.): 4-5.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 13-14,11-12.WEBS1 Row at midpt 4-14 REACTIONS (lb/size) 1 =1188/0-4-0 (min. 0-2-0) 10 =499/0-5-8 (min. 0-1-8) 13 =2188/0-5-8 (min. 0-4-1) Max Horz1 =-322(LC 6)Max Uplift1 =-137(LC 8)10 =-160(LC 7) Max Uplift13 =-239(LC 7) Max Grav 1 =1285(LC 2) 10 =809(LC 20) 13 =2572(LC 20) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD1-18=-1759/212, 2-18=-1472/230, 2-19=-1159/229, 19-20=-1135/232, 20-21=-971/233, 21-22=-880/246, 3-22=-770/260, 3-23=-845/264, 4-23=-1013/247, 4-5=-299/148, 5-24=-298/137, 6-24=-377/128, 6-25=-38/672, 7-25=-47/459, 7-26=-454/107, 8-26=-590/95, 8-10=-753/185BOT CHORD 1-28=-84/1250, 17-28=-84/1250, 17-29=-84/1250, 16-29=-84/1250, 16-30=0/765, 15-30=0/765, 15-31=0/760, 14-31=0/760, 13-14=-513/192, 6-13=-2028/326 WEBS2-17=0/275, 2-16=-768/219, 3-16=-188/688, 4-16=-315/140, 4-14=-1042/143, 6-14=-166/1335, 11-13=-41/437, 7-13=-1006/170 NOTES (13) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-2-0 to 3-7-14,Interior(1) 3-7-14 to 8-5-12, Exterior(2) 8-5-12 to 11-11-10, Interior(1) 15-5-8 to 16-5-9,Exterior(2) 19-8-5 to 36-3-0 zone; cantilever left and right exposed ;C-C for membersand forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-03) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 30.8 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.8) All bearings are assumed to be SPF No.2 . 9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 1=137, 10=160, 13=239.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. Continued on page 2 Job Q1103376 Truss H7 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:46:53 2011 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-OSrcHmxMXFrHwOBrQ1p85dWUNZxwFwburkkxkDzB?gG NOTES (13) 12) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 13) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss M1 Truss Type Half Hip Truss Qty 7 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:46:48 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-1U1jE3tEjjD?qdIteUEzOapZ1YDzal49iS0A2?zB?gL Scale = 1:52.5 W1 T1 T2 W6 B1W1W3 W4 W5 W7 W2 1 2 3 4 8 7 6 5 9 10 11 4x6 1.5x4 4x9 6x6 4x4 1.5x4 4x4 3x6 3x6 3x6 3x6 3x6 3x6 2-6-0 2-6-0 7-11-0 5-5-0 13-7-8 5-8-8 2-6-0 2-6-0 7-11-0 5-5-0 13-7-8 5-8-8 1-0-0 10-0-5 10-3-4 9-2-13 0-9-8 1-0-0 10.00 12 Plate Offsets (X,Y): [2:0-6-0,0-2-0], [4:0-2-8,Edge] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.870.880.63 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.15-0.250.04 (loc) 6-76-79 l/defl >999>620n/a L/d 240180n/a PLATES MT20 Weight: 79 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W6,W7: 2 X 4 SPF No.2BRACING TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc purlins (10-0-0 max.): 1-2.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 4-5, 2-6, 3-5JOINTS1 Brace at Jt(s): 1 REACTIONS (lb/size) 8 =682/0-5-8 (min. 0-1-8) 9 =699/0-3-8 (min. 0-1-12) Max Horz 8 =286(LC 9)Max Uplift8 =-7(LC 8)9 =-223(LC 9)Max Grav8 =884(LC 13) Max Grav9 =1114(LC 13) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-10=-1170/0, 3-10=-759/0, 3-4=-312/190, 5-9=-98/789, 4-9=-325/132BOT CHORD7-8=-177/2517, 6-7=-187/2522, 6-11=-127/787, 5-11=-127/787WEBS2-6=-1750/68, 3-6=0/449, 3-5=-1071/168, 2-8=-2628/0 NOTES (13)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-1-12 to 2-6-0, Interior(1) 2-6-0 to 13-2-4 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-03) Unbalanced snow loads have been considered for this design. 4) Provide adequate drainage to prevent water ponding.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.7) All bearings are assumed to be SPF No.2 . 8) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grainformula. Building designer should verify capacity of bearing surface.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) 8 except (jt=lb) 9=223.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 12) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails.13) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss M2 Truss Type Monopitch Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:46:41 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-k864mgnrMZK_UYGXjVcJc50ROjyVRZp75tqIJvzB?gS Scale = 1:34.7 T1 W5 B1 W3 W4W1 W2 BL1 1 2 3 4 7 6 5 8 9 10 11 4x9 3x4 1.5x4 3x4 4x4 3x4 3x4 3x4 6-1-14 6-1-14 12-3-12 6-1-14 -1-4-0 1-4-0 6-1-14 6-1-14 12-3-12 6-1-14 1-5-1 6-4-1 1-0-0 4.79 12 Plate Offsets (X,Y): [4:Edge,0-1-9] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.570.350.66 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.04-0.100.04 (loc) 6-76-79 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 61 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W5,W1: 2 X 4 SPF No.2 OTHERS 2 X 4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)7 =738/0-5-8 (min. 0-1-8)9 =574/0-3-8 (min. 0-1-8)Max Horz7 =184(LC 8) Max Uplift 7 =-127(LC 8) 9 =-142(LC 9) Max Grav7 =773(LC 2)9 =687(LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD2-10=-799/24, 3-10=-648/38, 5-8=-58/422, 4-8=-58/422, 2-7=-726/166 BOT CHORD 5-6=-137/671 WEBS 3-5=-713/148, 2-6=0/684 NOTES (12)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -1-4-0 to 1-8-0,Interior(1) 1-8-0 to 11-10-8 zone; cantilever left and right exposed ;C-C for members andforces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 30.8 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.7) All bearings are assumed to be SPF No.2 . 8) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 7=127, 9=142.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard Job Q1103376 Truss M3 Truss Type Monopitch Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:44:15 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-03It7l0Flixiz66TAr_4hJzRxt_9EaJdW9SZANzB?ik Scale: 1/4"=1' W1 T2 B1 W2 W3 W4 W6 W5 T1 1 2 3 4 7 6 5 8 9 10 11 12 13 14 15 16 3x6 4x4 4x4 3x4 3x4 6x6 3x6 9-8-0 9-8-0 19-4-0 9-8-0 6-6-8 6-6-8 12-9-8 6-3-0 19-4-0 6-6-8 8-10-11 3-3-0 3.50 12 SKHH28L (USP) FROM 2X8 HEADER Plate Offsets (X,Y): [3:0-2-4,Edge] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.790.940.49 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.29-0.580.03 (loc) 6-76-75 l/defl >793>396n/a L/d 240180n/a PLATES MT20 Weight: 91 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W2,W6: 2 X 4 SPF No.2BRACING TOP CHORD Structural wood sheathing directly applied or 4-10-3 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 2-2-0 oc bracing.WEBS1 Row at midpt 1-7, 2-7, 3-5 REACTIONS (lb/size)7 =1099/Mechanical5 =1064/0-5-8 (min. 0-1-12)Max Horz 7 =-212(LC 7) Max Uplift 7 =-252(LC 7) 5 =-124(LC 7)Max Grav7 =1296(LC 3)5 =1114(LC 3) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-7=-310/94, 2-10=-1022/116, 3-10=-1157/102, 4-5=-255/99 BOT CHORD 7-13=0/845, 13-14=0/845, 6-14=0/845, 6-15=-96/1072, 15-16=-96/1072, 5-16=-96/1072 WEBS2-7=-1188/279, 2-6=-39/518, 3-5=-1266/114 NOTES (11)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 16-2-4, Exterior(2) 16-2-4 to 19-2-4 zone; cantilever left and rightexposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.6) All bearings are assumed to be SPF No.2 . 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 252 lb uplift at joint 7 and 124 lb uplift at joint 5.9) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 11) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard Job Q1103376 Truss M3G Truss Type Monopitch Truss Qty 1 Ply 2 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:46:34 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-RoBQIHiR0QS_8TEBpX_gpdDJSvYIIL15UHdQZpzB?gZ Scale = 1:46.9 W1 T1 B1 W2 W3 W4 W5 W6 W7 W9W8 1 2 3 4 5 10 9 8 7 6 11 12 13 14 15 16 4x6 1.5x4 3x12 MT20H 5x8 6x6 4x12 7x8 4x6 4x9 6x6 0-0-12 0-0-12 4-10-12 4-10-0 9-6-0 4-7-4 13-9-10 4-3-10 18-4-13 4-7-2 4-10-12 4-10-12 9-6-0 4-7-4 13-9-10 4-3-10 18-4-13 4-7-2 8-7-6 3-3-0 3.50 12 Plate Offsets (X,Y): [7:0-3-8,0-2-0], [8:0-2-8,0-4-12] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15NOIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.300.390.86 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.09-0.170.03 (loc) 886 l/defl >999>999n/a L/d 240180n/a PLATES MT20MT20H Weight: 254 lb FT = 10% GRIP 197/144148/108 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 6 SPF 1650F 1.5EWEBS2 X 4 SPF Stud *Except* W5: 2 X 10 SYP DSS, W9,W8: 2 X 4 SPF No.2BRACING TOP CHORD Structural wood sheathing directly applied or 4-11-0 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 1-10, 2-10, 3-9 REACTIONS (lb/size)10 =3909/0-6-4 (min. 0-3-3)6 =4057/0-5-8 (min. 0-3-4)Max Horz 10 =-201(LC 6) Max Uplift 10 =-803(LC 6) 6 =-718(LC 6)Max Grav10 =4093(LC 3)6 =4105(LC 3) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 2-11=-2711/472, 11-12=-2778/466, 3-12=-2825/466, 3-13=-6075/1108, 4-13=-6129/1099, 4-5=-4352/772, 5-6=-4047/732 BOT CHORD 10-14=-328/2667, 9-14=-328/2667, 9-15=-984/5832, 15-16=-984/5832, 8-16=-984/5832, 7-8=-713/4133WEBS2-10=-4643/921, 2-9=-731/3988, 3-9=-4925/1018, 3-8=-849/4380,4-8=-399/2377, 4-7=-2544/502, 5-7=-839/4882 NOTES (14)1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2 X 4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc. Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc, 2 X 10 - 2 rows at 0-5-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been providedto distribute only loads noted as (F) or (B), unless otherwise indicated.3) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; LumberDOL=1.33 plate grip DOL=1.33 4) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.15) Unbalanced snow loads have been considered for this design. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.8) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.9) All bearings are assumed to be SPF No.2 . 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 10=803, 6=718. 11) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 13) Hanger(s) or other connection device(s) shall be provided sufficient to supportconcentrated load(s) 6000 lb down and 1164 lb up at 9-6-0 on bottom chord. Thedesign/selection of such connection device(s) is the responsibility of others.14) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard 1) Snow: Lumber Increase=1.15, Plate Increase=1.15Continued on page 2 Job Q1103376 Truss M3G Truss Type Monopitch Truss Qty 1 Ply 2 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:46:34 2011 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-RoBQIHiR0QS_8TEBpX_gpdDJSvYIIL15UHdQZpzB?gZ LOAD CASE(S)StandardUniform Loads (plf)Vert: 1-5=-82, 10-14=-20, 9-14=-60, 9-15=-20, 15-16=-60, 6-16=-20Concentrated Loads (lb)Vert: 8=-6000(F) Job Q1103376 Truss S1 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:39:28 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-vrSNucYEKXnQ1?fJs3KnYnaZwAAWUjZOW?RtcVzB?nD Scale = 1:44.4 T1 T1 B1 B1 W5 W4 W3 W3 W2 W4 W3 W3 W2 W1 W1 1 2 3 4 5 6 7 14 13 12 11 10 9 8 15 16 17 18 19 3x8 4x6 3x8 6x9 0-5-8 0-5-8 2-11-7 2-5-15 5-7-5 2-7-15 8-3-4 2-7-15 10-11-3 2-7-15 13-7-1 2-7-15 16-1-0 2-5-15 16-6-8 0-5-8 2-11-7 2-11-7 5-7-5 2-7-15 8-3-4 2-7-15 10-11-3 2-7-15 13-7-1 2-7-15 16-6-8 2-11-7 1-6-0 8-4-11 1-6-0 6-6-2 10.00 12 10.00 12 Plate Offsets (X,Y): [8:0-3-0,0-0-7], [14:0-3-0,0-0-7] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 1-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.110.330.73 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.11-0.210.39 (loc) 11118 l/defl >999>903n/a L/d 240180n/a PLATES MT20 Weight: 80 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W1: 2 X 6 SPF 1650F 1.5EBRACING TOP CHORD Structural wood sheathing directly applied or 4-10-10 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)14 =409/0-5-8 (min. 0-1-8)8 =409/0-5-8 (min. 0-1-8)Max Horz14 =-96(LC 6)Max Uplift 14 =-54(LC 8) 8 =-53(LC 9) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD1-2=-844/151, 2-15=-1299/170, 3-15=-1238/173, 3-16=-1440/96, 16-17=-1425/98, 4-17=-1413/102, 4-18=-1413/119, 5-18=-1440/113, 5-19=-1238/133, 6-19=-1299/126, 6-7=-844/120, TOP CHORD1-2=-844/151, 2-15=-1299/170, 3-15=-1238/173, 3-16=-1440/96, 16-17=-1425/98, 4-17=-1413/102, 4-18=-1413/119, 5-18=-1440/113, 5-19=-1238/133, 6-19=-1299/126, 6-7=-844/120, 1-14=-405/89, 7-8=-405/75 BOT CHORD 12-13=-212/813, 11-12=-214/1266, 10-11=-63/1266, 9-10=-95/813WEBS4-11=-134/1698, 6-10=-33/361, 6-9=-309/50, 7-9=-66/624, 2-12=-1/361, 2-13=-309/64, 1-13=-91/624 NOTES (12)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-2-12 to 2-11-7, Interior(1) 2-11-7 to 5-3-4, Exterior(2) 5-3-4 to 8-3-4, Interior(1) 11-3-4 to 13-3-12 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) All plates are 3x6 MT20 unless otherwise indicated.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.7) All bearings are assumed to be SPF No.2 . 8) Bearing at joint(s) 14, 8 considers parallel to grain value using ANSI/TPI 1 angle tograin formula. Building designer should verify capacity of bearing surface.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 54 lb uplift at joint 14 and 53 lb uplift at joint 8.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 12) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard Job Q1103376 Truss S2 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:39:23 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-ZteUrvU5W_98xEnL3Wlcrkth69ReqU?fNjj6xIzB?nI Scale = 1:51.1 0-1-15 0-1-15 W1 T1 T2 T2 T1 W8 B1 B1 W2 W3 W4 W3 W5 W6 W5 W3 W4 W3 W7 BL1 1 2 3 4 5 6 7 14 13 12 11 10 9 8 15 16 17 18 19 20 21 22 3x6 4x9 4x6 4x9 5x12 3x6 3x6 3x6 7x8 3x6 3x6 3x6 3x6 1.5x4 4x6 0-5-8 0-5-8 3-4-13 2-11-5 5-10-0 2-5-4 8-3-4 2-5-4 10-8-8 2-5-4 13-1-11 2-5-4 16-6-8 3-4-13 3-4-13 3-4-13 5-10-0 2-5-4 8-3-4 2-5-4 10-8-8 2-5-4 13-1-11 2-5-4 16-6-8 3-4-13 4-2-1 8-4-11 4-2-1 0-7-4 6-6-2 10.00 12 10.00 12 LUS26 FROM G3 GIRDER Plate Offsets (X,Y): [2:0-3-8,0-2-4], [6:0-3-8,0-2-4], [7:0-4-8,0-2-12], [14:0-3-0,0-0-7] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 1-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.180.510.62 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.20-0.310.53 (loc) 111115 l/defl >972>627n/a L/d 240180n/a PLATES MT20 Weight: 88 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W1: 2 X 6 SPF 1650F 1.5E, W6: 2 X 4 SPF No.2 OTHERS 2 X 6 SPF 1650F 1.5E BRACING TOP CHORD Structural wood sheathing directly applied or 3-10-7 oc purlins, except end verticals, and2-0-0 oc purlins (5-6-1 max.): 1-2, 6-7.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.JOINTS1 Brace at Jt(s): 1, 7 REACTIONS (lb/size)14 =410/Mechanical 15 =388/0-3-8 (min. 0-1-8) Max Horz 14 =-59(LC 6) Max Uplift14 =-57(LC 8)15 =-50(LC 9)Max Grav14 =506(LC 20) Max Grav15 =491(LC 20) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-14=-488/80, 1-16=-1135/137, 2-16=-1134/137, 2-17=-1977/211, 17-18=-1934/212, 3-18=-1898/216, 3-19=-2184/187, 4-19=-2125/192, 4-5=-2184/192, 5-20=-1907/217, 20-21=-1944/213, 6-21=-1986/212, 6-22=-1150/139, 7-22=-1150/139BOT CHORD12-13=-176/1303, 11-12=-196/1915, 10-11=-195/1925, 9-10=-160/1324WEBS1-13=-144/1204, 2-13=-1239/166, 2-12=-28/483, 3-12=-254/28, 4-11=-209/2541, 6-10=-27/475, 6-9=-1238/163, 7-9=-138/1171 NOTES (14) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-2-12 to 3-4-13,Interior(1) 3-4-13 to 5-3-4, Exterior(2) 5-3-4 to 8-3-4, Interior(1) 11-3-4 to 13-1-11 zone;cantilever left and right exposed ;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-03) Unbalanced snow loads have been considered for this design. 4) Provide adequate drainage to prevent water ponding.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections. 9) Bearing at joint(s) 15 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 57 lb uplift at joint 14 and 50 lb uplift at joint 15.11) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 13) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened totruss TC w/ 2-10d nails.14) All Plates 20 Gauge Unless Noted Continued on page 2 Job Q1103376 Truss S2 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:39:23 2011 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-ZteUrvU5W_98xEnL3Wlcrkth69ReqU?fNjj6xIzB?nI LOAD CASE(S)Standard Job Q1103376 Truss S3 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:39:18 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-CwrboBQyhSWrqTvOHz9R8gAkw8lA99ivDS0LG4zB?nN Scale = 1:54.4 0-1-15 0-1-15 W1 T1 T2 T2 T1 W7B1B1 W2 W3 W4 W5 W4 W3 W6 BL1 1 2 3 4 5 10 9 8 7 6 11 12 13 14 15 16 17 18 19 20 21 22 4x6 4x9 4x6 4x9 5x12 3x6 6x9 3x6 3x6 1.5x4 4x6 4x6 0-5-8 0-5-8 5-4-13 4-11-5 8-3-4 2-10-7 11-1-11 2-10-7 16-6-8 5-4-13 5-4-13 5-4-13 8-3-4 2-10-7 11-1-11 2-10-7 16-6-8 5-4-13 5-10-18-4-11 5-10-1 0-7-4 6-6-2 10.00 12 10.00 12 LUS26 FROM G3 GIRDER Plate Offsets (X,Y): [2:0-3-4,0-2-4], [4:0-3-4,0-2-4], [5:0-4-8,0-2-12], [10:0-3-0,0-0-7] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 1-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.530.400.88 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.17-0.300.49 (loc) 8811 l/defl >999>648n/a L/d 240180n/a PLATES MT20 Weight: 92 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W1: 2 X 6 SPF 1650F 1.5E OTHERS 2 X 6 SPF 1650F 1.5E BRACING TOP CHORD Structural wood sheathing directly applied or 4-3-0 oc purlins, except end verticals, and2-0-0 oc purlins (4-4-7 max.): 1-2, 4-5.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.JOINTS1 Brace at Jt(s): 1, 5 REACTIONS (lb/size)10 =410/Mechanical 11 =388/0-3-8 (min. 0-1-8) Max Horz 10 =35(LC 7) Max Uplift10 =-61(LC 6)11 =-56(LC 7)Max Grav10 =523(LC 19) Max Grav11 =487(LC 19) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-10=-509/87, 1-12=-1279/193, 12-13=-1279/193, 13-14=-1279/193, 2-14=-1278/193, 2-15=-1806/237, 15-16=-1769/238, 16-17=-1755/239, 3-17=-1725/243, 3-18=-1734/243, 18-19=-1755/239, 4-19=-1805/236, 4-20=-1283/194, 20-21=-1284/194, 21-22=-1284/194, 5-22=-1284/194BOT CHORD8-9=-228/1494, 7-8=-230/1501WEBS1-9=-195/1304, 2-9=-1213/212, 3-8=-272/2050, 4-7=-1208/210, 5-7=-190/1280 NOTES (14) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-2-12 to 3-2-12,Interior(1) 3-2-12 to 5-4-13, Exterior(2) 5-4-13 to 8-3-4, Interior(1) 11-1-11 to 12-11-4zone; cantilever left and right exposed ;C-C for members and forces & MWFRS forreactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-03) Unbalanced snow loads have been considered for this design. 4) Provide adequate drainage to prevent water ponding.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections. 9) Bearing at joint(s) 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 61 lb uplift at joint 10 and 56 lb uplift at joint 11.11) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 13) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened totruss TC w/ 2-10d nails.14) All Plates 20 Gauge Unless Noted Continued on page 2 Job Q1103376 Truss S3 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:39:18 2011 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-CwrboBQyhSWrqTvOHz9R8gAkw8lA99ivDS0LG4zB?nN LOAD CASE(S)Standard Job Q1103376 Truss S4 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:39:14 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-K8c5yqNSdD0PMrbd274V_q?zIXLTDLDKIq286JzB?nR Scale = 1:43.0 BL1 T1 B1 B1 W1 W2 W3 W4 W5 W6 W5 W4 W3 W2 W1 BL1 T2 1 2 3 4 5 6 7 8 15 14 13 12 11 10 9 16 5x6 3x4 3x6 4x4 4x6 5x6 10x12 5x6 4x6 4x4 3x6 5x6 3x6 3x6 0-5-8 0-5-8 2-11-7 2-5-15 5-7-5 2-7-15 8-3-4 2-7-15 10-11-3 2-7-15 13-7-1 2-7-15 16-1-0 2-5-15 16-6-8 0-5-8 2-11-7 2-11-7 5-7-5 2-7-15 8-3-4 2-7-15 10-11-3 2-7-15 13-7-1 2-7-15 16-1-0 2-5-15 16-6-8 0-5-8 7-6-1 6-6-2 10.00 12 LUS26 FROM G3 GIRDER Plate Offsets (X,Y): [1:0-2-0,0-2-12], [3:0-2-8,0-1-12], [5:0-2-8,0-1-12], [8:0-2-0,0-2-12], [9:0-3-0,0-0-7], [12:0-6-0,0-6-0], [15:0-3-0,0-0-7] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.950.570.85 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.30-0.591.01 (loc) 12129 l/defl >645>329n/a L/d 240180n/a PLATES MT20 Weight: 112 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W5: 2 X 4 SPF No.2 OTHERS 2 X 6 SPF 1650F 1.5E BRACING TOP CHORD 2-0-0 oc purlins (2-1-8 max.): 1-8.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.JOINTS1 Brace at Jt(s): 1, 8 REACTIONS (lb/size)15 =817/Mechanical9 =817/0-5-8 (min. 0-1-8) Max Uplift 15 =-159(LC 6) 9 =-159(LC 6) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD1-15=-790/170, 1-2=-369/72, 2-3=-1069/207, 3-16=-4433/865, 4-16=-4433/865, 4-5=-4433/865, 5-6=-1069/207, 6-7=-1069/207, TOP CHORD1-15=-790/170, 1-2=-369/72, 2-3=-1069/207, 3-16=-4433/865, 4-16=-4433/865, 4-5=-4433/865, 5-6=-1069/207, 6-7=-1069/207, 7-8=-369/72, 8-9=-790/170 BOT CHORD 13-14=-104/506, 12-13=-271/1368, 11-12=-271/1368, 10-11=-104/506WEBS1-14=-149/768, 2-14=-945/224, 2-13=-199/1030, 3-13=-1210/272,3-12=-678/3466, 5-12=-678/3466, 5-11=-1210/272, 7-11=-199/1030, 7-10=-945/224, 8-10=-149/768 NOTES (13)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-2-12 to 2-11-7, Interior(1) 2-11-7 to 13-3-12, Exterior(2) 13-3-12 to 16-3-12 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-03) Provide adequate drainage to prevent water ponding.4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.6) All bearings are assumed to be SPF No.2 . 7) Refer to girder(s) for truss to truss connections.8) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grainformula. Building designer should verify capacity of bearing surface.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 159 lb uplift at joint 15 and 159 lb uplift at joint 9.10) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 12) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened totruss TC w/ 2-10d nails.13) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss S5 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:39:07 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-1ohRURI3H48P0mZH79SsCMDwvj1n4F3IhErGNDzB?nY Scale = 1:52.2 W1 T1 W1 B1 B1 W2 W3 W4 W5 W4 W3 W2 1 2 3 4 5 10 9 8 7 6 11 12 13 14 5x6 3x6 4x4 6x9 1.5x4 4x4 3x6 5x6 3x6 3x6 0-5-8 0-5-8 4-3-6 3-9-14 8-3-4 3-11-14 12-3-2 3-11-14 16-1-0 3-9-14 16-6-8 0-5-8 4-3-6 4-3-6 8-3-4 3-11-14 12-3-2 3-11-14 16-6-8 4-3-6 9-2-1 6-6-2 10.00 12 LUS26 FROM G3 GIRDER Plate Offsets (X,Y): [1:0-2-0,0-3-0], [5:0-2-0,0-3-0], [6:0-3-0,0-0-7], [10:0-3-0,0-0-7] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.260.190.62 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.07-0.130.23 (loc) 886 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 114 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W1: 2 X 6 SPF 1650F 1.5EBRACING TOP CHORD 2-0-0 oc purlins (4-9-2 max.): 1-5, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 1-10, 5-6JOINTS1 Brace at Jt(s): 1, 5 REACTIONS (lb/size)10 =817/Mechanical 6 =817/0-5-8 (min. 0-1-8) Max Uplift 10 =-159(LC 6) 6 =-159(LC 6) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD1-10=-787/176, 1-11=-467/90, 2-11=-467/90, 2-12=-1441/283, TOP CHORD1-10=-787/176, 1-11=-467/90, 2-11=-467/90, 2-12=-1441/283, 3-12=-1441/283, 3-13=-1441/283, 4-13=-1441/283, 4-14=-467/90, 5-14=-467/90, 5-6=-787/176 BOT CHORD 8-9=-131/622, 7-8=-131/622 WEBS1-9=-152/789, 2-9=-930/244, 2-8=-223/1128, 3-8=-297/110, 4-8=-223/1128, 4-7=-930/244, 5-7=-152/789 NOTES (13)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-2-12 to 3-2-12,Interior(1) 3-2-12 to 13-3-12, Exterior(2) 13-3-12 to 16-3-12 zone; cantilever left and rightexposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0 3) Provide adequate drainage to prevent water ponding.4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members. 6) All bearings are assumed to be SPF No.2 . 7) Refer to girder(s) for truss to truss connections.8) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grainformula. Building designer should verify capacity of bearing surface.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 159 lb uplift at joint 10 and 159 lb uplift at joint 6.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 13) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard Job Q1103376 Truss S6 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:39:01 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-CeJADNDIhENFIr57nvLSy5zvqI?wgSnPJIOy9ZzB?ne Scale = 1:61.5 W1 T1 W1 B1 B1 W2 W3 W4 W5 W4 W3 W2 1 2 3 4 5 10 9 8 7 6 11 12 13 14 5x6 3x6 3x4 6x9 1.5x4 3x4 3x6 5x6 3x6 3x6 0-5-8 0-5-8 4-3-6 3-9-14 8-3-4 3-11-14 12-3-2 3-11-14 16-1-0 3-9-14 16-6-8 0-5-8 4-3-6 4-3-6 8-3-4 3-11-14 12-3-2 3-11-14 16-6-8 4-3-6 10-10-1 6-6-2 10.00 12 LUS26 FROM G3 GIRDER Plate Offsets (X,Y): [1:0-2-0,0-3-0], [5:0-2-0,0-3-0], [6:0-3-0,0-0-7], [10:0-3-0,0-0-7] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.230.160.93 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.04-0.080.15 (loc) 88-96 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 131 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W1: 2 X 6 SPF 1650F 1.5EBRACING TOP CHORD 2-0-0 oc purlins (6-0-0 max.): 1-5, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 1-10, 5-6JOINTS1 Brace at Jt(s): 1, 5 REACTIONS (lb/size)10 =817/Mechanical 6 =817/0-5-8 (min. 0-1-8) Max Uplift 10 =-159(LC 6) 6 =-159(LC 6) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD1-10=-785/176, 1-11=-360/69, 2-11=-360/69, 2-12=-845/166, TOP CHORD1-10=-785/176, 1-11=-360/69, 2-11=-360/69, 2-12=-845/166, 3-12=-845/166, 3-13=-845/166, 4-13=-845/166, 4-14=-360/69, 5-14=-360/69, 5-6=-785/176 BOT CHORD 8-9=-105/484, 7-8=-105/484 WEBS1-9=-141/730, 2-9=-842/227, 2-8=-136/687, 3-8=-308/112, 4-8=-136/687, 4-7=-842/227, 5-7=-141/730 NOTES (13)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-2-12 to 3-2-12,Interior(1) 3-2-12 to 13-3-12, Exterior(2) 13-3-12 to 16-3-12 zone; cantilever left and rightexposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0 3) Provide adequate drainage to prevent water ponding.4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members. 6) All bearings are assumed to be SPF No.2 . 7) Refer to girder(s) for truss to truss connections.8) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grainformula. Building designer should verify capacity of bearing surface.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 159 lb uplift at joint 10 and 159 lb uplift at joint 6.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 13) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard Job Q1103376 Truss S6A Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:38:57 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-Kt4fO0Ane?tqpEoMY3HWoFoEtheykejqOgQk0ozB?ni Scale = 1:67.2 W1 T1 W7 B1 B1 W2 W3 W4 W5 W4 W3 W6 BL1 1 2 3 4 5 10 9 8 7 6 11 12 13 14 15 5x6 5x12 3x6 3x4 6x9 1.5x4 3x4 3x6 3x6 1.5x4 4x6 4x6 4x6 0-5-8 0-5-8 4-3-6 3-9-14 8-3-4 3-11-14 12-3-2 3-11-14 16-6-8 4-3-6 4-3-6 4-3-6 8-3-4 3-11-14 12-3-2 3-11-14 16-6-8 4-3-6 10-10-1 0-7-4 6-6-2 10.00 12LUS26 FROM G3 GIRDER Plate Offsets (X,Y): [1:0-2-0,0-3-0], [5:0-3-8,0-3-0], [10:0-3-0,0-0-7] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.230.160.93 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.04-0.080.14 (loc) 88-911 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 142 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W1: 2 X 6 SPF 1650F 1.5E, W7: 2 X 4 SPF No.2 OTHERS 2 X 6 SPF 1650F 1.5E BRACING TOP CHORD 2-0-0 oc purlins (6-0-0 max.): 1-5, except end verticals.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 1-10, 5-6JOINTS1 Brace at Jt(s): 1, 5 REACTIONS (lb/size) 10 =821/Mechanical 11 =775/0-3-8 (min. 0-1-8) Max Uplift 10 =-159(LC 6)11 =-150(LC 6) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD1-10=-789/177, 1-12=-361/70, 2-12=-361/70, 2-13=-854/167, TOP CHORD1-10=-789/177, 1-12=-361/70, 2-12=-361/70, 2-13=-854/167, 3-13=-854/167, 3-14=-854/167, 4-14=-854/167, 4-15=-363/70, 5-15=-363/70 BOT CHORD 8-9=-105/486, 7-8=-105/488 WEBS1-9=-142/734, 2-9=-847/228, 2-8=-138/696, 3-8=-315/114, 4-8=-138/694, 4-7=-823/219, 5-7=-138/719 NOTES (13)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-2-12 to 3-2-12,Interior(1) 3-2-12 to 12-11-4, Exterior(2) 12-11-4 to 15-11-4 zone; cantilever left and rightexposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0 3) Provide adequate drainage to prevent water ponding.4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members. 6) All bearings are assumed to be SPF No.2 . 7) Refer to girder(s) for truss to truss connections.8) Bearing at joint(s) 11 considers parallel to grain value using ANSI/TPI 1 angle to grainformula. Building designer should verify capacity of bearing surface.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 159 lb uplift at joint 10 and 150 lb uplift at joint 11.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 13) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard Job Q1103376 Truss S7 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:38:54 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-vIOXl_8vL4VFyn3ntwjpAdAjfTcRXRlNijC4PTzB?nl Scale = 1:69.8 W1 T1 W1 B1 B1 W2 W3 W4 W5 W4 W3 W2 1 2 3 4 5 10 9 8 7 6 11 12 13 14 5x6 3x6 3x4 6x9 1.5x4 3x4 3x6 5x6 3x6 3x6 0-5-8 0-5-8 4-3-6 3-9-14 8-3-4 3-11-14 12-3-2 3-11-14 16-1-0 3-9-14 16-6-8 0-5-8 4-3-6 4-3-6 8-3-4 3-11-14 12-3-2 3-11-14 16-6-8 4-3-6 12-6-1 6-6-2 10.00 12 LUS26 FROM G3 GIRDER Plate Offsets (X,Y): [1:0-2-0,0-3-0], [5:0-2-0,0-3-0], [6:0-3-0,0-0-7], [10:0-3-0,0-0-7] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.230.150.37 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.04-0.070.13 (loc) 88-96 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 149 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W1: 2 X 6 SPF 1650F 1.5E, W2: 2 X 4 SPF No.2BRACING TOP CHORD 2-0-0 oc purlins (6-0-0 max.): 1-5, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 1-10, 5-6, 2-9, 4-7JOINTS1 Brace at Jt(s): 1, 5 REACTIONS (lb/size)10 =817/Mechanical 6 =817/0-5-8 (min. 0-1-8) Max Uplift 10 =-159(LC 6) 6 =-159(LC 6) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD1-10=-784/176, 1-11=-293/57, 2-11=-293/57, 2-12=-597/117, TOP CHORD1-10=-784/176, 1-11=-293/57, 2-11=-293/57, 2-12=-597/117, 3-12=-597/117, 3-13=-597/117, 4-13=-597/117, 4-14=-293/57, 5-14=-293/57, 5-6=-784/176 BOT CHORD 8-9=-88/397, 7-8=-88/397 WEBS1-9=-135/701, 2-9=-787/216, 2-8=-105/528, 3-8=-309/112, 4-8=-105/528, 4-7=-787/216, 5-7=-135/701 NOTES (13)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-2-12 to 3-2-12,Interior(1) 3-2-12 to 13-3-12, Exterior(2) 13-3-12 to 16-3-12 zone; cantilever left and rightexposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0 3) Provide adequate drainage to prevent water ponding.4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members. 6) All bearings are assumed to be SPF No.2 . 7) Refer to girder(s) for truss to truss connections.8) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grainformula. Building designer should verify capacity of bearing surface.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 159 lb uplift at joint 10 and 159 lb uplift at joint 6.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 13) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard Job Q1103376 Truss S7A Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:38:48 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-481GVx38lEk5EscdWgdPxMwhC2Z17jEVKnlmCqzB?nr Scale = 1:79.5 W1 T1 W7 B1 B1 W2 W3 W4 W5 W4 W3 W6 BL1 1 2 3 4 5 10 9 8 7 6 11 12 13 14 15 5x6 5x12 3x6 3x4 6x9 1.5x4 3x4 3x6 3x6 1.5x4 4x6 4x6 4x6 0-5-8 0-5-8 4-3-6 3-9-14 8-3-4 3-11-14 12-3-2 3-11-14 16-6-8 4-3-6 4-3-6 4-3-6 8-3-4 3-11-14 12-3-2 3-11-14 16-6-8 4-3-6 12-6-1 0-7-4 6-6-2 10.00 12LUS26 FROM G3 GIRDER Plate Offsets (X,Y): [1:0-2-0,0-3-0], [5:0-3-8,0-3-0], [10:0-3-0,0-0-7] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.230.150.37 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.04-0.070.12 (loc) 88-911 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 162 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W1: 2 X 6 SPF 1650F 1.5E, W7,W2,W6: 2 X 4 SPF No.2 OTHERS 2 X 6 SPF 1650F 1.5E BRACING TOP CHORD 2-0-0 oc purlins (6-0-0 max.): 1-5, except end verticals.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 1-10, 2-9, 4-7JOINTS1 Brace at Jt(s): 1, 5 REACTIONS (lb/size) 10 =821/Mechanical 11 =775/0-3-8 (min. 0-1-8) Max Uplift 10 =-159(LC 6)11 =-150(LC 6) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD1-10=-788/176, 1-12=-294/57, 2-12=-294/57, 2-13=-603/118, TOP CHORD1-10=-788/176, 1-12=-294/57, 2-12=-294/57, 2-13=-603/118, 3-13=-603/118, 3-14=-603/118, 4-14=-603/118, 4-15=-296/57, 5-15=-296/57 BOT CHORD 8-9=-88/399, 7-8=-88/401 WEBS1-9=-136/704, 2-9=-792/217, 2-8=-106/535, 3-8=-316/115, 4-8=-106/533, 4-7=-767/209, 5-7=-132/690 NOTES (13)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-2-12 to 3-2-12,Interior(1) 3-2-12 to 12-11-4, Exterior(2) 12-11-4 to 15-11-4 zone; cantilever left and rightexposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0 3) Provide adequate drainage to prevent water ponding.4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members. 6) All bearings are assumed to be SPF No.2 . 7) Refer to girder(s) for truss to truss connections.8) Bearing at joint(s) 11 considers parallel to grain value using ANSI/TPI 1 angle to grainformula. Building designer should verify capacity of bearing surface.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 159 lb uplift at joint 10 and 150 lb uplift at joint 11.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 13) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard Job Q1103376 Truss S8 Truss Type Half Hip Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:39:42 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-VXIgqOj01qYRj9k?h0b37k9wWq?lm8lSkBqd6hzB?n? Scale = 1:76.2 T1 W8 B1 B1 W2 W3 W4 W5 W6 W7 W2 W1 1 2 3 4 5 10 9 8 7 6 11 12 13 14 3x6 3x6 3x4 6x9 1.5x4 3x4 3x6 5x6 3x6 3x6 0-5-8 0-5-8 4-3-8 3-10-0 8-3-4 3-11-12 12-3-2 3-11-14 16-1-0 3-9-14 16-6-8 0-5-8 0-3-12 0-3-12 4-3-8 3-11-12 8-3-4 3-11-12 12-3-2 3-11-14 16-6-8 4-3-6 13-7-14 6-6-2 10.00 12 LUS26 FROM G3 GIRDER Plate Offsets (X,Y): [5:0-2-0,0-3-0], [6:0-3-0,0-0-7], [10:0-3-0,0-0-7] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.230.140.36 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.04-0.070.12 (loc) 88-96 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 162 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF No.2 *Except* W8,W1: 2 X 6 SPF 1650F 1.5E, W4,W5,W6: 2 X 4 SPF StudBRACING TOP CHORD 2-0-0 oc purlins (6-0-0 max.): 1-5, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 5-6, 2-9, 4-7, 1-10JOINTS1 Brace at Jt(s): 1, 5 REACTIONS (lb/size)10 =817/Mechanical 6 =817/0-5-4 (min. 0-1-8) Max Uplift 10 =-159(LC 6) 6 =-159(LC 6) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD1-11=-260/50, 2-11=-260/50, 2-12=-496/97, 3-12=-496/97, TOP CHORD1-11=-260/50, 2-11=-260/50, 2-12=-496/97, 3-12=-496/97, 3-13=-496/97, 4-13=-496/97, 4-14=-260/50, 5-14=-260/50, 5-6=-784/175, 1-10=-784/176 BOT CHORD 8-9=-80/355, 7-8=-80/354 WEBS1-9=-133/688, 2-9=-761/211, 2-8=-93/467, 3-8=-307/111, 4-8=-93/468, 4-7=-761/211, 5-7=-133/688 NOTES (13)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-2-12 to 3-2-12,Interior(1) 3-2-12 to 13-3-12, Exterior(2) 13-3-12 to 16-3-12 zone; cantilever left and rightexposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0 3) Provide adequate drainage to prevent water ponding.4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members. 6) All bearings are assumed to be SPF No.2 . 7) Refer to girder(s) for truss to truss connections.8) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grainformula. Building designer should verify capacity of bearing surface.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 159 lb uplift at joint 10 and 159 lb uplift at joint 6.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 13) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard Job Q1103376 Truss S9 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:39:49 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-otDJIooPO_QR2DmLb_DivDy6deOzvCvTLm0UrnzB?mu Scale = 1:57.5 W1 T1 W1 B1 B1 W2 W3 W4 W5 W4 W3 W2 1 2 3 4 5 10 9 8 7 6 11 12 13 14 5x6 3x6 4x4 6x9 1.5x4 4x4 3x6 5x6 3x6 3x6 0-5-8 0-5-8 4-3-6 3-9-14 8-3-4 3-11-14 12-3-2 3-11-14 16-1-0 3-9-14 16-6-8 0-5-8 4-3-6 4-3-6 8-3-4 3-11-14 12-3-2 3-11-14 16-6-8 4-3-6 10-1-5 6-6-2 10.00 12 LUS26 FROM G3 GIRDER Plate Offsets (X,Y): [1:0-2-0,0-3-0], [5:0-2-0,0-3-0], [6:0-3-0,0-0-7], [10:0-3-0,0-0-7] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.240.170.78 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.05-0.090.17 (loc) 88-96 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 123 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W1: 2 X 6 SPF 1650F 1.5EBRACING TOP CHORD 2-0-0 oc purlins (5-7-14 max.): 1-5, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 1-10, 5-6JOINTS1 Brace at Jt(s): 1, 5 REACTIONS (lb/size)10 =817/Mechanical 6 =817/0-5-8 (min. 0-1-8) Max Uplift 10 =-159(LC 6) 6 =-159(LC 6) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD1-10=-786/176, 1-11=-400/77, 2-11=-400/77, 2-12=-1033/202, TOP CHORD1-10=-786/176, 1-11=-400/77, 2-11=-400/77, 2-12=-1033/202, 3-12=-1033/202, 3-13=-1033/202, 4-13=-1033/202, 4-14=-400/77, 5-14=-400/77, 5-6=-786/176 BOT CHORD 8-9=-115/535, 7-8=-115/535 WEBS1-9=-145/751, 2-9=-875/233, 2-8=-162/818, 3-8=-305/112, 4-8=-162/818, 4-7=-875/233, 5-7=-145/751 NOTES (13)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-2-12 to 3-2-12,Interior(1) 3-2-12 to 13-3-12, Exterior(2) 13-3-12 to 16-3-12 zone; cantilever left and rightexposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0 3) Provide adequate drainage to prevent water ponding.4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members. 6) All bearings are assumed to be SPF No.2 . 7) Refer to girder(s) for truss to truss connections.8) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grainformula. Building designer should verify capacity of bearing surface.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 159 lb uplift at joint 10 and 159 lb uplift at joint 6.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 13) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard Job Q1103376 Truss T1 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:46:24 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-ktbeCsaAMLBOxwTGERoKPWpXdt2WzqjcBjCuCOzB?gj Scale = 1:80.9 0-1-15 0-1-15 T2 T3 T4 T5 T6 W16 B1 W3 W4 W5 W6 W7 W8 W9 W10 W11 W13 W14 W15 W1 W2 T1 B212 3 4 5 6 7 8 9 10 11 12 19 18 17 16 15 14 13 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 3x6 4x6 10x12 5x6 3x4 4x9 3x4 4x6 4x4 6x9 4x9 5x6 4x9 4x4 10x12 4x4 3x8 7-4-12 7-4-12 14-6-0 7-1-4 23-9-0 9-3-0 25-3-0 1-6-0 30-6-0 5-3-0 31-10-8 1-4-8 -1-4-0 1-4-0 5-0-5 5-0-5 9-9-3 4-8-13 14-6-0 4-8-13 19-1-8 4-7-8 23-9-0 4-7-8 25-3-0 1-6-0 27-10-8 2-7-8 30-6-0 2-7-8 31-10-8 1-4-8 1-0-0 5-2-9 13-1-0 13-6-14 1-0-0 5-2-9 10.00 12 Plate Offsets (X,Y): [2:0-1-11,0-2-0], [8:0-2-7,0-3-8], [9:0-3-0,0-1-8], [14:0-6-0,0-3-5], [17:0-4-8,0-3-4] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.580.800.85 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.41-0.720.11 (loc) 16-1716-1713 l/defl >932>526n/a L/d 240180n/a PLATES MT20 Weight: 184 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5EBOT CHORD 2 X 4 SPF 1650F 1.5EWEBS2 X 4 SPF Stud *Except* W4,W5,W6,W7,W8: 2 X 4 SPF No.2, W1: 2 X 6 SPF 1650F 1.5EBRACING TOP CHORD Structural wood sheathing directly applied or 2-11-13 oc purlins, except end verticals, and 2-0-0 oc purlins (4-7-6 max.): 8-9, 11-12.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 5-17, 6-17, 7-17, 4-19JOINTS1 Brace at Jt(s): 12 REACTIONS (lb/size) 13 =1769/0-4-0 (min. 0-3-8) 19 =1946/0-5-8 (min. 0-3-1) Max Horz 19 =368(LC 7)Max Uplift13 =-190(LC 9)19 =-257(LC 8)Max Grav13 =2212(LC 22) Max Grav19 =1946(LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-20=-497/153, 3-20=-353/164, 3-4=-348/176, 4-21=-2074/329, 5-21=-1956/352, 5-22=-1736/353, 22-23=-1724/353, 23-24=-1684/362, 6-24=-1631/376, 6-25=-1682/379, 25-26=-1880/357, 7-26=-1938/356, 7-27=-3329/521, 8-27=-3684/506, 8-9=-2314/320, 9-10=-3182/379, 10-28=-4196/439, 11-28=-4388/430, 2-19=-578/247BOT CHORD19-29=-223/1546, 29-30=-223/1546, 18-30=-223/1546, 18-31=-138/1417, 31-32=-138/1417, 17-32=-138/1417, 17-33=-83/1909, 33-34=-83/1909, 16-34=-83/1909, 15-16=-204/2748, 14-15=-267/2724, 13-14=-338/3543 WEBS 5-18=-97/346, 5-17=-621/208, 6-17=-353/1768, 7-17=-1338/283, 7-16=-249/1781, 8-16=-1271/312, 8-15=-1382/88, 9-15=-183/1688, 10-15=-529/144, 10-14=-74/971, 11-14=-894/130, 11-13=-3783/354, 4-19=-1816/152 NOTES (13) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -1-4-0 to 1-10-4,Interior(1) 1-10-4 to 11-3-12, Exterior(2) 11-3-12 to 14-6-0, Interior(1) 17-8-4 to 23-9-0,Exterior(2) 25-3-0 to 31-8-12 zone; cantilever left and right exposed ;C-C for membersand forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-03) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 times flat roof load of 30.8 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.8) All bearings are assumed to be SPF No.2 . 9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 13=190, 19=257.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. Continued on page 2 Job Q1103376 Truss T1 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:46:25 2011 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-C381PCbo7fJFZ42Sn8JZyjMhNGOliHzmPNySkqzB?gi NOTES (13) 12) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 13) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss T2 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:46:20 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-r6L8MUXfJ6hzTJ9V?bkOFgesHFh510U1G5Eh3dzB?gn Scale = 1:78.8 0-1-15 0-1-15 T2 T3 T4 T3 T5 W16 B1 W3 W4 W5 W6 W7 W8 W9 W10 W11 W12 W13 W14 W15 W1 W2 B212 3 4 5 6 7 8 9 10 11 12 19 18 17 16 15 14 13 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 3x8 4x6 7x8 5x6 3x4 4x9 3x4 4x6 4x4 5x9 5x6 6x9 3x4 4x4 3x6 7x8 4x4 3x8 7-4-12 7-4-12 14-6-0 7-1-4 21-9-0 7-3-0 23-3-0 1-6-0 30-6-0 7-3-0 31-10-8 1-4-8 -1-4-0 1-4-0 5-0-5 5-0-5 9-9-3 4-8-13 14-6-0 4-8-13 18-1-8 3-7-8 21-9-0 3-7-8 23-3-0 1-6-0 26-10-8 3-7-8 30-6-0 3-7-8 31-10-8 1-4-8 1-0-0 6-10-9 13-1-0 13-6-14 1-0-0 6-10-9 10.00 12 Plate Offsets (X,Y): [2:0-1-11,0-2-0], [8:0-3-8,0-2-7], [9:0-3-0,0-2-1], [17:0-4-8,0-3-0] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.540.700.86 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.28-0.480.10 (loc) 16-1716-1713 l/defl >999>795n/a L/d 240180n/a PLATES MT20 Weight: 193 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5EBOT CHORD 2 X 4 SPF 1650F 1.5EWEBS2 X 4 SPF Stud *Except* W4,W5,W6,W7,W8: 2 X 4 SPF No.2, W1: 2 X 6 SPF 1650F 1.5EBRACING TOP CHORD Structural wood sheathing directly applied or 2-9-12 oc purlins, except end verticals, and 2-0-0 oc purlins (4-7-4 max.): 8-9, 11-12.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 5-17, 6-17, 7-17, 8-16, 3-19JOINTS1 Brace at Jt(s): 12 REACTIONS (lb/size) 13 =1743/0-4-0 (min. 0-3-7) 19 =1943/0-5-8 (min. 0-3-1) Max Horz 19 =368(LC 7)Max Uplift13 =-188(LC 9)19 =-257(LC 8)Max Grav13 =2196(LC 22) Max Grav19 =1943(LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-20=-494/155, 3-20=-350/178, 3-21=-2069/332, 4-21=-1967/340, 4-5=-1952/355, 5-22=-1702/359, 22-23=-1690/359, 23-24=-1644/371, 6-24=-1637/382, 6-25=-1802/396, 7-25=-1844/378, 7-26=-2742/498, 8-26=-3021/487, 8-9=-2274/342, 9-27=-2706/369, 27-28=-2853/357, 10-28=-2904/351, 10-11=-4463/432, 2-19=-576/248BOT CHORD19-29=-227/1542, 29-30=-227/1542, 18-30=-227/1542, 18-31=-143/1407, 31-32=-143/1407, 17-32=-143/1407, 17-33=-56/1721, 33-34=-56/1721, 16-34=-56/1721, 15-16=-133/2082, 14-15=-245/2556, 13-14=-324/3588 WEBS 5-18=-94/372, 5-17=-633/207, 6-17=-379/1786, 7-17=-1311/285, 7-16=-252/1509, 8-16=-2049/352, 9-16=-65/797, 9-15=-93/592, 10-15=-653/180, 10-14=-92/1206, 11-14=-995/165, 11-13=-3848/336, 3-19=-1813/153 NOTES (13) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -1-4-0 to 1-10-4,Interior(1) 1-10-4 to 11-3-12, Exterior(2) 11-3-12 to 14-6-0, Interior(1) 17-8-4 to 21-9-0,Exterior(2) 23-3-0 to 31-8-12 zone; cantilever left and right exposed ;C-C for membersand forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-03) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 times flat roof load of 30.8 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.8) All bearings are assumed to be SPF No.2 . 9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 13=188, 19=257.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. Continued on page 2 Job Q1103376 Truss T2 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:46:20 2011 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-r6L8MUXfJ6hzTJ9V?bkOFgesHFh510U1G5Eh3dzB?gn NOTES (13) 12) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 13) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss T3 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:46:15 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-V8YFJnTXUa3gMYHXC28DYcxwqE2PMkUI6qXwOQzB?gs Scale = 1:76.6 0-1-15 0-1-15T2 T3 T4 T5 B1 W3 W4 W5 W6 W7 W8 W9 W10 W11 W12W1 W2 W1 W13B212 3 4 5 6 7 8 9 1011 18 17 16 15 14 13 12 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 3x8 4x6 8x9 5x6 3x4 4x4 4x4 5x8 4x4 3x4 3x6 5x6 4x4 3x8 3x4 4x9 7-4-12 7-4-12 14-6-0 7-1-4 19-9-0 5-3-0 21-3-0 1-6-0 25-8-12 4-5-12 30-6-0 4-9-4 -1-4-0 1-4-0 5-0-5 5-0-5 9-9-3 4-8-13 14-6-0 4-8-13 19-9-0 5-3-0 21-3-0 1-6-0 25-8-12 4-5-12 30-6-0 4-9-4 31-10-0 1-4-0 1-0-0 8-6-9 13-1-0 13-6-14 1-0-0 8-6-9 10.00 12 Plate Offsets (X,Y): [2:0-1-11,0-2-0], [7:0-3-8,0-2-7], [8:0-3-0,0-2-1], [16:0-4-0,0-3-0] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.840.480.91 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.17-0.290.07 (loc) 16-1716-1712 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 191 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5EBOT CHORD 2 X 4 SPF 1650F 1.5EWEBS2 X 4 SPF Stud *Except* W4,W5,W6,W7: 2 X 4 SPF No.2, W1: 2 X 6 SPF 1650F 1.5EBRACING TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc purlins (5-1-6 max.): 7-8.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 12-13.WEBS1 Row at midpt 5-16, 7-16, 7-15, 3-18 REACTIONS (lb/size)18 =1840/0-5-8 (min. 0-2-14) 12 =1782/0-5-8 (min. 0-3-13) Max Horz 18 =-347(LC 6) Max Uplift18 =-248(LC 8)12 =-249(LC 9)Max Grav18 =1840(LC 1) Max Grav12 =2416(LC 20) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-19=-476/155, 3-19=-333/178, 3-20=-1935/319, 4-20=-1833/327, 4-5=-1815/342, 5-21=-1486/342, 21-22=-1474/351, 22-23=-1404/355, 6-23=-1381/367, 6-24=-1259/356, 24-25=-1450/342, 25-26=-1493/340, 7-26=-1704/334, 7-8=-1658/318, 8-27=-1996/329, 9-27=-2227/308, 9-28=-2147/268, 28-29=-2359/253, 10-29=-2537/246, 2-18=-564/248, 10-12=-2360/310BOT CHORD18-30=-212/1444, 30-31=-212/1444, 17-31=-212/1444, 17-32=-130/1294, 32-33=-130/1294, 16-33=-130/1294, 16-34=-2/1658, 15-34=-2/1658, 14-15=0/1548, 13-14=-63/1781 WEBS 5-17=-91/401, 5-16=-647/201, 6-16=-316/1357, 7-16=-1030/239, 7-15=-522/103, 8-15=-70/667, 8-14=-79/299, 9-14=-333/143, 3-18=-1698/143, 10-13=-101/1634 NOTES (13) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -1-4-0 to 1-8-10,Interior(1) 1-8-10 to 11-5-6, Exterior(2) 11-5-6 to 14-6-0, Interior(1) 17-6-10 to 19-9-0,Exterior(2) 21-3-0 to 31-10-0 zone; cantilever left and right exposed ;C-C for membersand forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-03) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 30.8 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.8) All bearings are assumed to be SPF No.2 . 9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 18=248, 12=249.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. Continued on page 2 Job Q1103376 Truss T3 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:46:15 2011 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-V8YFJnTXUa3gMYHXC28DYcxwqE2PMkUI6qXwOQzB?gs NOTES (13) 12) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 13) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss T4 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:46:08 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-CodbrOO88QAg0TFBI4Wam89rfQfkDd0GVEK2eKzB?gz Scale = 1:82.0 0-1-15 0-1-15 T2 T3 T4 T5 B1 W3 W4 W5 W6 W7 W8 W9 W8 W10 W11 W12 W1 W2 W1 W13T1 T6B212 3 4 5 6 7 8 9 10 11 12 13 20 19 18 17 16 15 14 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 3x6 4x6 6x6 5x8 3x6 3x4 4x4 4x4 5x8 3x4 4x4 4x4 3x4 4x6 4x4 3x8 12x12 7-4-12 7-4-12 14-6-0 7-1-4 17-9-0 3-3-0 19-3-0 1-6-0 24-8-12 5-5-12 30-6-0 5-9-4 -1-4-0 1-4-0 5-0-5 5-0-5 9-9-3 4-8-13 14-6-0 4-8-13 17-9-0 3-3-0 19-3-0 1-6-0 22-10-13 3-7-13 26-6-11 3-7-13 30-6-0 3-11-5 31-10-0 1-4-0 1-0-0 10-2-913-1-0 13-6-14 1-0-0 10-2-9 10.00 12 Plate Offsets (X,Y): [2:0-1-11,0-2-0], [7:0-2-5,Edge], [8:0-2-4,0-3-4], [14:Edge,0-3-8], [18:0-4-0,0-3-0] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.390.480.77 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.17-0.290.08 (loc) 18-1918-1914 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 207 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5EBOT CHORD 2 X 4 SPF 1650F 1.5EWEBS2 X 4 SPF No.2 *Except* W3,W10,W11,W12,W2,W13: 2 X 4 SPF Stud, W1: 2 X 6 SPF 1650F 1.5EBRACING TOP CHORD Structural wood sheathing directly applied or 4-6-1 oc purlins, except end verticals, and 2-0-0 oc purlins (5-10-8 max.): 7-8.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 5-18, 6-18, 7-18, 7-17, 8-17, 4-20, 10-14 REACTIONS (lb/size)20 =1849/0-5-8 (min. 0-2-14)14 =1826/0-5-8 (min. 0-3-11) Max Horz 20 =-347(LC 6) Max Uplift 20 =-248(LC 8)14 =-248(LC 9)Max Grav20 =1849(LC 1)14 =2363(LC 20) Max Grav20 =1849(LC 1) 14 =2363(LC 20) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-21=-472/156, 3-21=-330/167, 3-4=-324/179, 4-22=-1950/324, 5-22=-1832/347, 5-23=-1499/349, 23-24=-1487/358, 24-25=-1396/363, 6-25=-1393/375, 6-7=-1602/386, 7-26=-1439/322, 8-26=-1440/321, 8-27=-1815/350, 9-27=-2006/333, 9-28=-2140/321, 28-29=-2297/311, 10-29=-2459/303, 10-11=-372/111, 11-30=-395/101, 12-30=-576/93, 2-20=-562/249, 12-14=-684/191BOT CHORD20-31=-217/1455, 31-32=-217/1455, 19-32=-217/1455, 19-33=-135/1309, 33-34=-135/1309, 18-34=-135/1309, 18-35=-22/1440, 17-35=-22/1440, 16-17=-5/1427, 16-36=-20/1699, 36-37=-20/1699, 15-37=-20/1699, 14-15=-66/1806WEBS5-19=-89/396, 5-18=-643/205, 6-18=-367/1516, 7-18=-1072/258, 7-17=-365/119, 8-17=-109/312, 8-16=-85/707, 9-16=-592/158, 9-15=-70/258, 4-20=-1716/146, 10-14=-2224/179 WEBS5-19=-89/396, 5-18=-643/205, 6-18=-367/1516, 7-18=-1072/258, 7-17=-365/119, 8-17=-109/312, 8-16=-85/707, 9-16=-592/158, 9-15=-70/258, 4-20=-1716/146, 10-14=-2224/179 NOTES (13) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -1-4-0 to 1-8-10,Interior(1) 1-8-10 to 11-5-6, Exterior(2) 11-5-6 to 22-3-10, Interior(1) 22-3-10 to 28-9-6zone; cantilever left and right exposed ;C-C for members and forces & MWFRS forreactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-03) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 30.8 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.8) All bearings are assumed to be SPF No.2 . Continued on page 2 Job Q1103376 Truss T4 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:46:08 2011 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-CodbrOO88QAg0TFBI4Wam89rfQfkDd0GVEK2eKzB?gz NOTES (13) 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 20=248, 14=248. 10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to trussTC w/ 2-10d nails.13) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard Job Q1103376 Truss T5 Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:46:01 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-vSiyN_IlnHIfhOCrN6ux_fMfEbFS4RVEue7AvDzB?h4 Scale = 1:84.2 0-1-15 0-1-15 T2 T3 T5 B1 W3 W4 W5 W6 W7 W8 W9 W10 W1 W2 W12 BL1 T1 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10 16 17 18 19 20 21 22 23 24 25 26 3x6 4x4 4x9 6x9 4x9 3x8 3x4 4x4 4x4 3x8 4x4 1.5x4 3x4 3x6 3x4 3x4 3x4 7-4-12 7-4-12 14-6-0 7-1-4 15-9-0 1-3-0 17-3-0 1-6-0 19-8-0 2-5-0 -1-4-0 1-4-0 5-0-5 5-0-5 9-9-3 4-8-13 14-6-0 4-8-13 15-9-0 1-3-0 17-3-0 1-6-0 19-8-0 2-5-0 1-0-0 11-10-9 13-1-0 13-6-14 0-9-8 11-10-9 10.00 12 Plate Offsets (X,Y): [7:0-3-8,0-2-4], [8:0-6-12,Edge], [9:0-2-14,0-2-0] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.330.520.82 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.13-0.230.02 (loc) 13-1413-1416 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 190 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF No.2 *Except* W3,W2: 2 X 4 SPF Stud, W1: 2 X 6 SPF 1650F 1.5E OTHERS 2 X 4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 5-7-1 oc purlins, except end verticals, and2-0-0 oc purlins (6-0-0 max.): 7-8.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 5-13, 7-12, 8-11, 9-10, 8-10 REACTIONS (lb/size)15 =1199/0-5-8 (min. 0-1-14) 16 =1051/0-3-8 (min. 0-1-10) Max Horz 15 =369(LC 8) Max Uplift15 =-127(LC 8)16 =-188(LC 9) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD2-17=-361/139, 3-18=-1067/100, 4-18=-948/111, 4-5=-841/123, 5-19=-552/116, 19-20=-413/121, 20-21=-368/125, 6-21=-348/132, 6-7=-408/155, 7-8=-261/110, 2-15=-480/237, 10-16=-180/970 BOT CHORD 15-23=-261/817, 23-24=-261/817, 14-24=-261/817, 14-25=-163/606, 25-26=-163/606, 13-26=-163/606, 12-13=-55/261WEBS5-14=-106/474, 5-13=-614/219, 6-13=-85/251, 7-13=-84/554, 7-12=-785/136, 8-12=-167/751, 3-15=-914/0, 8-10=-944/187 NOTES (14)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -1-4-0 to 1-8-0, Interior(1) 1-8-0 to 11-6-0, Exterior(2) 11-6-0 to 19-2-12 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-03) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.8) All bearings are assumed to be SPF No.2 . 9) Bearing at joint(s) 16 considers parallel to grain value using ANSI/TPI 1 angle to grainformula. Building designer should verify capacity of bearing surface.10) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 15=127, 16=188. 11) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 13) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened totruss TC w/ 2-10d nails.14) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss T6GE Truss Type Common Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:45:57 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-0gSRXdFEj2oECnv49Gp?ppB?H_0x8pNez09zmSzB?h8 Scale = 1:21.6 W1 T1 T1 W1 B1 ST1 1 2 3 4 5 8 7 6 9 10 11 12 1.5x4 3x4 4x4 3x4 1.5x4 1.5x4 5-4-0 5-4-0 -1-4-0 1-4-0 2-8-0 2-8-0 5-4-0 2-8-0 6-8-0 1-4-0 1-0-0 3-2-11 3-8-9 1-0-0 10.00 12 LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLLBCDL 30.8 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.20 0.050.06 DEFL Vert(LL) Vert(TL)Horz(TL) in -0.02 -0.020.00 (loc) 5 56 l/defl n/r n/rn/a L/d 120 90n/a PLATES MT20 Weight: 23 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF StudOTHERS2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 5-4-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS (lb/size)8 =242/5-4-0 (min. 0-1-8)6 =242/5-4-0 (min. 0-1-8)7 =269/5-4-0 (min. 0-1-8)Max Horz8 =66(LC 7)Max Uplift 8 =-130(LC 8) 6 =-132(LC 9) Max Grav 8 =257(LC 2)6 =257(LC 3)7 =269(LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES (15) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Corner(3) zone; cantilever leftand right exposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) Truss designed for wind loads in the plane of the truss only. For studs exposed towind (normal to the face), see MiTek "Standard Gable End Detail"3) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 30.8 psf on overhangs non-concurrent with other live loads. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).8) Gable studs spaced at 2-0-0 oc.9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.10) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.11) All bearings are assumed to be SPF No.2 . 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 8=130, 6=132. 13) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 14) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 15) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss T7GE Truss Type Common Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:45:54 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-c5nIvbDMR7PfLJAVT8GICBZU?n?2xSyCH3xJ97zB?hB Scale = 1:28.3 W1 T1 T1 W1 B1 ST3 ST2 ST1 ST2 ST1 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 18 19 20 3x4 4x4 3x4 10-0-0 10-0-0 -1-4-0 1-4-0 5-0-0 5-0-0 10-0-0 5-0-0 11-4-0 1-4-0 1-0-0 5-2-0 5-7-14 1-0-0 10.00 12 LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLLBCDL 30.8 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.21 0.060.10 DEFL Vert(LL) Vert(TL)Horz(TL) in -0.02 -0.020.00 (loc) 9 910 l/defl n/r n/rn/a L/d 120 90n/a PLATES MT20 Weight: 47 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF StudOTHERS2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS All bearings 10-0-0.(lb) - Max Horz16=-121(LC 6)Max UpliftAll uplift 100 lb or less at joint(s) 10, 14, 12, 11 except 16=-115(LC 6), 15=-112(LC 7)Max Grav All reactions 250 lb or less at joint(s) 16, 10, 15, 11 except 13=315(LC 1), 14=260(LC 2), 12=260(LC 3) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES (16) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Corner(3) -1-4-0 to 1-8-0,Exterior(2) 1-8-0 to 2-0-0, Corner(3) 2-0-0 to 5-0-0, Exterior(2) 8-0-0 to 8-4-0 zone;cantilever left and right exposed ;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.33 plate grip DOL=1.332) Truss designed for wind loads in the plane of the truss only. For studs exposed towind (normal to the face), see MiTek "Standard Gable End Detail"3) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 30.8 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Truss to be fully sheathed from one face or securely braced against lateral movement(i.e. diagonal web).9) Gable studs spaced at 2-0-0 oc.10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads.11) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf. 12) All bearings are assumed to be SPF No.2 . 13) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 14, 12, 11 except (jt=lb) 16=115, 15=112. 14) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.15) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 16) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss T8GE Truss Type Common Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:45:50 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-kKXo3EArNuvDsiskEIBM1LPre9d5?eOcMRz50MzB?hF Scale = 1:30.6 W1 T1 T1 W1 B1 ST3 ST2 ST1 ST2 ST11 2 3 4 5 6 7 14 13 12 11 10 9 8 15 16 17 18 2x4 4x4 2x4 11-1-2 11-1-2 5-6-9 5-6-9 11-1-2 5-6-9 1-0-0 5-7-7 1-0-0 10.00 12 LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLLBCDL 30.8 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.10 0.060.07 DEFL Vert(LL) Vert(TL)Horz(TL) in n/a n/a0.00 (loc) - - 8 l/defl n/a n/an/a L/d 999 999n/a PLATES MT20 Weight: 48 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF StudOTHERS2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS All bearings 11-1-2.(lb) - Max Horz14=-129(LC 6)Max UpliftAll uplift 100 lb or less at joint(s) 14, 8, 12, 10 except 13=-130(LC 8), 9=-127(LC 9)Max Grav All reactions 250 lb or less at joint(s) 14, 8, 13, 9 except 11=254(LC 1), 12=264(LC 2), 10=264(LC 3) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES (15) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Corner(3) zone; cantilever leftand right exposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) Truss designed for wind loads in the plane of the truss only. For studs exposed towind (normal to the face), see MiTek "Standard Gable End Detail"3) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 2-0-0 oc.9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.10) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.11) All bearings are assumed to be SPF No.2 . 12) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) 14, 8, 12, 10 except (jt=lb) 13=130, 9=127. 13) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 14) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 15) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss T9SGE Truss Type GABLE Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:45:44 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-vAAXoA54n2948nPau14yo49fYlV2bp9k_VWnpjzB?hL Scale = 1:58.0 T1 T2 B1 W5 W4 W3W4W3W1 W2 W1 W2 ST5 ST6 ST3 ST4ST2ST1 ST5 ST6 ST3 ST4 ST2 ST1 B21 2 3 4 5 6 11 10 9 8 7 32 33 34 35 36 37 38 39 40 4x6 4x4 2x4 5x8 3x6 4x4 3x6 4x4 3x6 2x4 5-1-2 5-1-2 11-1-2 6-0-0 17-1-2 6-0-0 22-2-4 5-1-2 -1-4-0 1-4-0 5-1-2 5-1-2 11-1-2 6-0-0 17-1-2 6-0-0 22-2-4 5-1-2 1-0-0 10-2-15 10-8-13 1-0-0 10.00 12 Plate Offsets (X,Y): [6:0-1-0,0-1-12], [9:0-3-4,0-3-0] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.720.360.57 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.05-0.110.02 (loc) 8-98-97 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 151 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W5,W1: 2 X 4 SPF No.2 OTHERS 2 X 4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 4-0-12 oc purlins, except end verticals.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 10-11. REACTIONS (lb/size)11 =1292/0-5-8 (min. 0-2-0)7 =1163/0-5-8 (min. 0-1-13)Max Horz 11 =285(LC 7) Max Uplift 11 =-208(LC 8) 7 =-139(LC 9) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-32=-1376/172, 3-32=-1143/196, 3-33=-1034/213, TOP CHORD2-32=-1376/172, 3-32=-1143/196, 3-33=-1034/213, 33-34=-879/225, 4-34=-867/242, 4-35=-859/242, 35-36=-871/225, 36-37=-889/223, 5-37=-1028/212, 5-38=-1151/200, 6-38=-1383/184, 2-11=-1246/246, 6-7=-1118/178 BOT CHORD 10-11=-278/281, 10-39=-153/967, 9-39=-153/967, 9-40=-82/981, 8-40=-82/981WEBS4-9=-144/649, 5-9=-463/187, 3-9=-435/179, 2-10=-45/873, 6-8=-40/859 NOTES (14)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -1-4-0 to 1-8-0, Interior(1) 1-8-0 to 8-1-2, Exterior(2) 8-1-2 to 11-1-2, Interior(1) 14-1-2 to 19-0-8 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed towind (normal to the face), see MiTek "Standard Gable End Detail"3) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 30.8 psf on overhangs non-concurrent with other live loads.6) All plates are 1.5x4 MT20 unless otherwise indicated.7) Gable studs spaced at 2-0-0 oc.8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.9) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.10) All bearings are assumed to be SPF No.2 . 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 208 lb uplift at joint 11 and 139 lb uplift at joint 7. 12) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.13) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 14) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss T10 Truss Type Special Truss Qty 2 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:45:40 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-0Pw0zp2akqfefA6pfC00dE_zA76Nfxe83tYZgxzB?hP Scale = 1:62.7 T1 T2 T3 B2 W3 W4 W5 W6 W7 W8 W1 W2 W10W9 B11 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 17 18 19 20 21 22 23 4x4 3x4 3x4 3x6 4x4 3x8 4x12 1.5x4 3x4 4x6 4x9 4x6 5-8-5 5-8-5 12-7-6 6-11-1 17-0-3 4-4-13 21-8-8 4-8-5 -1-4-0 1-4-0 5-8-5 5-8-5 11-1-2 5-4-13 12-7-6 1-6-4 17-0-3 4-4-13 21-8-8 4-8-5 1-0-0 8-11-12 10-2-15 10-8-13 5-4-3 10.00 12 4.79 12 HUS26 FROM 2ND FLR. BEAM Plate Offsets (X,Y): [2:0-2-12,0-1-8] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15NOIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.740.470.80 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.06-0.150.02 (loc) 10-1210-128 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 131 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W5,W7,W1,W10: 2 X 4 SPF No.2BRACING TOP CHORD Structural wood sheathing directly applied or 4-6-5 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 3-10, 5-10, 5-9 REACTIONS (lb/size)8 =1518/Mechanical13 =1394/0-5-8 (min. 0-2-3)Max Horz 13 =237(LC 8) Max Uplift 8 =-153(LC 9) 13 =-190(LC 8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-14=-1518/136, 3-14=-1257/163, 3-15=-1092/174, TOP CHORD2-14=-1518/136, 3-14=-1257/163, 3-15=-1092/174, 15-16=-1076/187, 4-16=-937/203, 4-5=-1132/267, 5-17=-879/206, 17-18=-882/201, 6-18=-1007/195, 6-19=-773/135, 19-20=-881/127, 7-20=-973/127, 2-13=-1348/225, 7-8=-1474/204 BOT CHORD 12-13=-275/210, 12-21=-176/1057, 11-21=-176/1057, 10-11=-176/1057, 10-22=-78/870, 22-23=-78/870, 9-23=-78/870WEBS3-10=-463/176, 4-10=-185/1047, 5-10=-684/197, 6-9=-799/179, 2-12=0/883, 7-9=-124/1203 NOTES (12)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Automatic zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 153 lb uplift at joint 8 and 190 lb uplift at joint 13.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 12) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard1) Snow: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-2=-82, 2-4=-82, 4-5=-82, 5-7=-132, 12-13=-20, 12-21=-60, 21-22=-20,22-23=-60, 8-23=-20 Job Q1103376 Truss T10A Truss Type Special Truss Qty 3 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 14:11:58 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-2OqPPhqynFdmoroJCZC0SHrT?8Byhuxuz0UQofzCHwF Scale = 1:62.7 T1 T2 T3 B1 W1 W2 W3W4 W5 W6 W8W7 B2 1 2 3 4 5 6 11 10 9 8 7 12 13 14 15 16 17 18 19 20 213x8 4x6 3x4 3x6 1.5x4 3x8 4x12 1.5x4 3x4 4x9 4x6 6-2-11 6-2-11 13-5-14 7-3-3 17-10-11 4-4-13 22-7-0 4-8-5 6-2-11 6-2-11 11-11-10 5-8-15 13-5-14 1-6-4 17-10-11 4-4-13 22-7-0 4-8-5 0-3-4 8-11-12 10-2-15 5-4-3 10.00 12 4.79 12 HUS26 FROM 2ND FLR. BEAM Plate Offsets (X,Y): [1:0-7-0,0-0-12] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15NOIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.800.650.79 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.08-0.160.04 (loc) 1-119-117 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 124 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W3,W5,W8: 2 X 4 SPF No.2BRACING TOP CHORD Structural wood sheathing directly applied or 3-7-5 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 2-9, 4-9, 4-8 REACTIONS (lb/size)1 =1349/0-4-0 (min. 0-2-2)7 =1583/MechanicalMax Horz 1 =195(LC 8) Max Uplift 1 =-129(LC 8) 7 =-157(LC 9) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD1-12=-1852/173, 2-12=-1694/192, 2-13=-1176/182, TOP CHORD1-12=-1852/173, 2-12=-1694/192, 2-13=-1176/182, 3-13=-1006/210, 3-4=-1215/276, 4-14=-923/212, 14-15=-926/208, 5-15=-1054/201, 5-16=-820/142, 16-17=-921/134, 6-17=-1020/133, 6-7=-1540/213 BOT CHORD 1-18=-212/1307, 11-18=-212/1307, 11-19=-212/1307, 10-19=-212/1307, 9-10=-212/1307, 9-20=-86/935, 20-21=-86/935,8-21=-86/935WEBS2-11=0/301, 2-9=-682/206, 3-9=-193/1115, 4-9=-668/199, 5-8=-793/179, 6-8=-133/1269 NOTES (12)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-2-0 to 3-2-0, Interior(1) 3-2-0 to 8-11-10, Exterior(2) 8-11-10 to 11-11-10, Interior(1) 13-5-14 to 19-5-4 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.6) All bearings are assumed to be SPF No.2 . 7) Refer to girder(s) for truss to truss connections.8) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 1=129, 7=157.9) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.10) Load case(s) 1, 2, 3, 12, 13, 14, 15 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 12) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard1) Snow: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-3=-82, 3-4=-82, 4-6=-132, 1-18=-20, 18-19=-60, 19-20=-20, 20-21=-60,7-21=-202) Unbal.Snow-Left: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Continued on page 2 Job Q1103376 Truss T10A Truss Type Special Truss Qty 3 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 14:11:58 2011 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-2OqPPhqynFdmoroJCZC0SHrT?8Byhuxuz0UQofzCHwF LOAD CASE(S)StandardUniform Loads (plf)Vert: 1-13=-82, 3-13=-117, 3-4=-38, 4-6=-88, 1-18=-20, 18-19=-60, 19-20=-20,20-21=-60, 7-21=-203) Unbal.Snow-Right: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-38, 3-4=-120, 4-14=-170, 6-14=-132, 1-18=-20, 18-19=-60, 19-20=-20, 20-21=-60, 7-21=-20 12) 3rd Unbal.Snow-Left: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-3=-38, 3-4=-97, 4-6=-88, 1-18=-20, 18-19=-60, 19-20=-20, 20-21=-60, 7-21=-2013) 4th Unbal.Snow-Left: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-13=-82, 3-13=-117, 3-4=-38, 4-6=-88, 1-18=-20, 18-19=-60, 19-20=-20,20-21=-60, 7-21=-2014) 5th Unbal.Snow-Right: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf) Vert: 1-3=-38, 3-4=-120, 4-6=-88, 1-18=-20, 18-19=-60, 19-20=-20, 20-21=-60, 7-21=-20 15) 6th Unbal.Snow-Right: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-38, 3-4=-38, 4-17=-153, 6-17=-132, 1-18=-20, 18-19=-60, 19-20=-20,20-21=-60, 7-21=-20 Job Q1103376 Truss T11 Truss Type Special Truss Qty 2 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:45:32 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-FtR_H4yZcMenixUGBWs8JYfaXvP9nIszDec8OPzB?hX Scale = 1:58.0 T1 T2 T3 B2 W3 W4 W5 W6 W7 W8 W1 W2 W10W9 B11 2 3 4 5 6 7 12 11 10 9 8 13 14 15 16 17 18 19 20 21 22 4x6 2x4 3x6 4x4 5x9 4x12 1.5x4 1.5x4 4x4 4x9 4x6 4-8-0 4-8-0 4-10-12 0-2-12 12-7-6 7-8-10 17-0-3 4-4-13 21-8-8 4-8-5 -1-4-0 1-4-0 4-10-12 4-10-12 11-1-2 6-2-6 12-7-6 1-6-4 17-0-3 4-4-13 21-8-8 4-8-5 1-0-0 8-11-11 10-2-15 10-8-13 6-3-14 10.00 12 3.50 12 HUS26 FROM 2ND FLR. BEAM Plate Offsets (X,Y): [2:0-1-0,0-1-8], [10:0-2-8,0-3-4] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15NOIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.850.370.91 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.08-0.190.00 (loc) 10-1110-118 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 132 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W5,W7,W1,W10: 2 X 4 SPF No.2BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 6-0-0 oc bracing.WEBS1 Row at midpt 5-10, 5-9 REACTIONS (lb/size)8 =1182/Mechanical11 =1784/0-5-8 (min. 0-2-13)Max Horz 11 =262(LC 8) Max Uplift 8 =-183(LC 7) 11 =-348(LC 8)Max Grav8 =1260(LC 16)11 =1784(LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 2-13=-253/368, 3-13=-230/537, 3-14=-707/90, 14-15=-568/105, 4-15=-566/120, 4-5=-747/197, 5-16=-595/184, 16-17=-596/181, 6-17=-707/176, 6-18=-508/115, 18-19=-573/110, 7-19=-666/109, 7-8=-1161/202 BOT CHORD11-20=-299/164, 10-20=-299/164, 10-21=-46/524, 9-21=-46/524WEBS3-11=-1524/396, 3-10=-101/826, 4-10=-135/606, 5-10=-744/189, 6-9=-800/214, 2-11=-300/321, 7-9=-130/929 NOTES (13)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Automatic zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 183 lb uplift at joint 8 and 348 lb uplift at joint 11.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) Load case(s) 1, 2, 3, 12, 13, 14, 15, 16 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 13) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard1) Snow: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-2=-82, 2-4=-82, 4-5=-82, 5-7=-132, 11-12=-20, 11-20=-60, 10-20=-20,10-21=-60, 21-22=-20, 8-22=-602) Unbal.Snow-Left: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Continued on page 2 Job Q1103376 Truss T11 Truss Type Special Truss Qty 2 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:45:32 2011 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-FtR_H4yZcMenixUGBWs8JYfaXvP9nIszDec8OPzB?hX LOAD CASE(S)StandardUniform Loads (plf)Vert: 1-2=-82, 2-15=-82, 4-15=-117, 4-5=-38, 5-7=-88, 11-12=-20, 11-20=-60, 10-20=-20, 10-21=-60, 21-22=-20, 8-22=-603) Unbal.Snow-Right: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-38, 2-4=-38, 4-5=-122, 5-16=-172, 7-16=-132, 11-12=-20, 11-20=-60, 10-20=-20, 10-21=-60, 21-22=-20, 8-22=-60 12) IBC Snow on Overhangs: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-2=-82, 2-4=-20, 4-5=-20, 5-7=-70, 8-12=-2013) 3rd Unbal.Snow-Left: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-2=-38, 2-4=-38, 4-5=-99, 5-7=-88, 11-12=-20, 11-20=-60, 10-20=-20, 10-21=-60, 21-22=-20, 8-22=-6014) 4th Unbal.Snow-Left: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf) Vert: 1-2=-82, 2-15=-82, 4-15=-117, 4-5=-38, 5-7=-88, 11-12=-20, 11-20=-60, 10-20=-20, 10-21=-60, 21-22=-20, 8-22=-60 15) 5th Unbal.Snow-Right: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-38, 2-4=-38, 4-5=-122, 5-7=-88, 11-12=-20, 11-20=-60, 10-20=-20,10-21=-60, 21-22=-20, 8-22=-6016) 6th Unbal.Snow-Right: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-2=-38, 2-4=-38, 4-5=-38, 5-19=-157, 7-19=-132, 11-12=-20, 11-20=-60,10-20=-20, 10-21=-60, 21-22=-20, 8-22=-60 Job Q1103376 Truss T11A Truss Type Special Truss Qty 3 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:45:22 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-YxrCBfqHzINBVPjLbQhovRFsRt_eRokUw4Bc1_zB?hh Scale = 1:58.0 T1 T2 T3 B2 W2 W3 W4 W5 W6 W1 W8W7 B1 1 2 3 4 5 9 8 7 6 10 11 12 13 14 15 16 17 5x6 4x6 2x4 5x12 4x12 1.5x4 3x4 4x9 4x6 7-11-6 7-11-6 12-4-3 4-4-13 17-0-8 4-8-5 6-5-2 6-5-2 7-11-6 1-6-4 12-4-3 4-4-13 17-0-8 4-8-5 4-10-11 8-11-11 10-2-15 6-3-14 10.00 12 3.50 12 HUS26 FROM 2ND FLR. BEAM Plate Offsets (X,Y): [1:0-3-0,0-1-12], [8:0-5-8,0-3-0] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15NOIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.890.440.82 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.11-0.280.01 (loc) 8-98-96 l/defl >999>718n/a L/d 240180n/a PLATES MT20 Weight: 112 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2 *Except* T1: 2 X 4 SPF 1650F 1.5EBOT CHORD 2 X 4 SPF No.2 WEBS 2 X 4 SPF No.2 *Except* W2,W4,W6,W7: 2 X 4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 5-3-8 oc purlins, except end verticals.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 3-8, 3-7 REACTIONS (lb/size)6 =1295/Mechanical9 =1072/0-5-8 (min. 0-1-11) Max Horz 9 =-126(LC 6) Max Uplift 6 =-177(LC 7)9 =-88(LC 8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD1-10=-819/118, 10-11=-643/133, 2-11=-509/136, 2-3=-749/184, TOP CHORD1-10=-819/118, 10-11=-643/133, 2-11=-509/136, 2-3=-749/184, 3-12=-619/180, 12-13=-697/172, 4-13=-714/172, 4-14=-538/112, 5-14=-689/105, 1-9=-948/152, 5-6=-1195/197 BOT CHORD 8-16=-66/582, 7-16=-66/582 WEBS1-8=-56/543, 2-8=-100/635, 3-8=-642/192, 4-7=-724/214, 5-7=-124/967 NOTES (11)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Automatic zone; cantilever leftand right exposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.6) All bearings are assumed to be SPF No.2 . 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 177 lb uplift at joint 6 and 88 lb uplift at joint 9.9) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 11) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard 1) Snow: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-82, 2-3=-82, 3-5=-132, 9-15=-60, 8-15=-20, 8-16=-60, 16-17=-20, 6-17=-60 Job Q1103376 Truss T12A Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:43:29 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-MCWUT0TPaa8ES1bdUB9Iqc3YTKMnSipsx?J8Z1zB?jS Scale = 1:60.2 T1 T2 T3 B1 W3 W4 W5 W6 W7 W8 W9 W10W1 W12W11W2 T4 B2 1 2 3 4 5 6 7 8 15 14 13 12 11 10 9 16 17 18 19 20 21 22 23 24 25 4x6 4x6 5x6 4x12 3x4 4x6 3x6 3x8 5x12 3x4 3x4 3x4 4x9 5x8 MT20H 5x6 0-0-6 0-0-6 4-5-13 4-5-7 10-2-6 5-8-9 16-7-12 6-5-6 23-1-2 6-5-6 29-10-0 6-8-14 4-5-13 4-5-13 8-8-2 4-2-5 10-2-6 1-6-4 16-7-12 6-5-6 23-1-2 6-5-6 29-10-0 6-8-14 3-0-3 8-11-11 10-2-15 3-3-0 10.00 12 3.50 12 Plate Offsets (X,Y): [4:0-2-4,0-3-4], [7:0-6-0,Edge], [8:0-3-0,0-2-0], [9:0-3-8,Edge], [10:0-3-8,0-2-0], [13:0-6-0,0-2-4], [14:0-3-8,0-1-8] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15NOIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.920.600.82 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.18-0.300.07 (loc) 11-1311-139 l/defl >999>999n/a L/d 240180n/a PLATES MT20MT20H Weight: 161 lb FT = 10% GRIP 197/144148/108 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5E *Except* T3,T4: 2 X 4 SPF 2100F 1.8EBOT CHORD 2 X 4 SPF 1650F 1.5E WEBS 2 X 4 SPF Stud *Except* W5,W7,W1,W12,W11: 2 X 4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied, except end verticals.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 2-13, 4-13, 5-13 REACTIONS (lb/size)15 =1965/0-7-0 (min. 0-3-1)9 =2271/0-5-8 (min. 0-3-9) Max Horz 15 =-223(LC 6) Max Uplift 15 =-209(LC 7)9 =-334(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD1-16=-1677/196, 16-17=-1520/202, 2-17=-1473/210, TOP CHORD1-16=-1677/196, 16-17=-1520/202, 2-17=-1473/210, 2-18=-1831/288, 18-19=-1752/294, 3-19=-1716/309, 3-4=-2209/451, 4-20=-1667/326, 20-21=-1734/320, 5-21=-1869/313, 5-6=-2726/433, 6-22=-2483/399, 7-22=-2548/393, 7-23=-2591/390, 8-23=-2702/390, 1-15=-1931/225, 8-9=-2206/361BOT CHORD14-24=-121/1210, 13-24=-121/1210, 12-13=-280/2504, 11-12=-280/2504, 11-25=-337/2490, 10-25=-337/2490WEBS2-14=-587/122, 2-13=-100/266, 3-13=-465/2290, 4-13=-1365/294,5-13=-1276/277, 6-10=-918/219, 8-10=-353/2645, 1-14=-125/1408 NOTES (11) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Automatic zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.7) All bearings are assumed to be SPF No.2 . 8) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 209 lb uplift at joint 15 and 334 lb uplift at joint 9.9) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 11) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard1) Snow: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-3=-82, 3-4=-82, 4-8=-132, 14-15=-20, 14-24=-60, 12-24=-20, 11-12=-60,11-25=-20, 10-25=-60, 9-10=-20 Job Q1103376 Truss T12B Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:43:21 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-bg1ToHMOT68MUpz50V0QVwk9R5eya4kh5lNiHVzB?ja Scale = 1:60.2 T1 T2 T4 B1 W3 W4 W5 W6 W7 W8 W9 W10 W2W1 W12W11 T3 B2 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 17 18 19 20 21 22 23 5x6 5x6 5x6 5x8 3x4 6x12 3x6 5x6 3x4 3x4 4x9 5x8 MT20H 5x6 0-0-6 0-0-6 4-6-12 4-6-6 10-4-3 5-9-8 16-9-9 6-5-6 23-2-15 6-5-6 29-11-13 6-8-14 4-6-12 4-6-12 8-9-15 4-3-4 10-4-3 1-6-4 16-9-9 6-5-6 23-2-15 6-5-6 29-11-13 6-8-14 2-10-10 8-11-11 10-2-15 3-3-0 10.00 12 3.50 12 Plate Offsets (X,Y): [1:0-2-12,0-1-8], [4:0-2-4,0-3-4], [6:0-4-0,0-3-4], [7:0-3-0,0-2-0], [8:0-3-8,Edge], [9:0-3-8,0-2-0] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15NOIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.990.590.83 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.18-0.300.07 (loc) 10-1110-118 l/defl >999>999n/a L/d 240180n/a PLATES MT20MT20H Weight: 161 lb FT = 10% GRIP 197/144148/108 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5E *Except* T4,T3: 2 X 4 SPF 2100F 1.8EBOT CHORD 2 X 4 SPF 1650F 1.5E WEBS 2 X 4 SPF Stud *Except* W5,W7,W1,W12,W11: 2 X 4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied, except end verticals.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 2-11, 4-11, 5-11 REACTIONS (lb/size)13 =1971/0-7-0 (min. 0-3-1)8 =2280/0-5-8 (min. 0-3-9) Max Horz 13 =-224(LC 6) Max Uplift 13 =-209(LC 7)8 =-335(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD1-14=-1725/200, 14-15=-1568/211, 2-15=-1517/214, TOP CHORD1-14=-1725/200, 14-15=-1568/211, 2-15=-1517/214, 2-16=-1856/291, 3-16=-1738/311, 3-4=-2236/455, 4-17=-1691/329, 17-18=-1757/323, 5-18=-1891/316, 5-6=-2741/436, 6-19=-2484/399, 19-20=-2596/390, 7-20=-2707/390, 1-13=-1937/225, 7-8=-2215/362 BOT CHORD12-21=-122/1246, 11-21=-122/1246, 11-22=-282/2519, 10-22=-282/2519, 10-23=-340/2512, 9-23=-340/2512WEBS2-12=-556/119, 3-11=-469/2320, 4-11=-1380/296, 5-11=-1269/276, 6-9=-918/218, 1-12=-124/1422, 7-9=-350/2645 NOTES (14)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Automatic zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) All plates are MT20 plates unless otherwise indicated. 5) The solid section of the plate is required to be placed over the splice line at joint(s) 6.6) Plate(s) at joint(s) 6 checked for a plus or minus 1 degree rotation about its center. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.8) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.9) All bearings are assumed to be SPF No.2 . 10) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 209 lb uplift at joint 13 and 335 lb uplift at joint 8.11) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Load case(s) 1, 2, 3, 12, 13, 14, 15 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 13) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 14) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard1) Snow: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-3=-82, 3-4=-82, 4-7=-132, 12-13=-20, 12-21=-60, 21-22=-20, 10-22=-60,10-23=-20, 9-23=-60, 8-9=-20 2) Unbal.Snow-Left: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf)Continued on page 2 Job Q1103376 Truss T12B Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:43:21 2011 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-bg1ToHMOT68MUpz50V0QVwk9R5eya4kh5lNiHVzB?ja LOAD CASE(S)StandardUniform Loads (plf)Vert: 1-15=-82, 3-15=-140, 3-4=-38, 4-7=-88, 12-13=-20, 12-21=-60, 21-22=-20,10-22=-60, 10-23=-20, 9-23=-60, 8-9=-203) Unbal.Snow-Right: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-38, 3-4=-111, 4-17=-161, 7-17=-132, 12-13=-20, 12-21=-60, 21-22=-20, 10-22=-60, 10-23=-20, 9-23=-60, 8-9=-20 12) 3rd Unbal.Snow-Left: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-3=-38, 3-4=-113, 4-7=-88, 12-13=-20, 12-21=-60, 21-22=-20, 10-22=-60,10-23=-20, 9-23=-60, 8-9=-2013) 4th Unbal.Snow-Left: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-15=-82, 3-15=-140, 3-4=-38, 4-7=-88, 12-13=-20, 12-21=-60, 21-22=-20,10-22=-60, 10-23=-20, 9-23=-60, 8-9=-2014) 5th Unbal.Snow-Right: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-38, 3-4=-111, 4-7=-88, 12-13=-20, 12-21=-60, 21-22=-20, 10-22=-60, 10-23=-20, 9-23=-60, 8-9=-20 15) 6th Unbal.Snow-Right: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf)Vert: 1-3=-38, 3-4=-38, 4-18=-151, 7-18=-132, 12-13=-20, 12-21=-60, 21-22=-20,10-22=-60, 10-23=-20, 9-23=-60, 8-9=-20 Job Q1103376 Truss T12C Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:43:18 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-A5LK9FKVABmodLFWKNTjtI6ebudbNihEPn82gAzB?jd Scale = 1:60.2 T1 T2 T3 B1 W3 W4 W5 W6 W7 W8 W9 W10W2W1 W12W11 T4 B2 1 2 3 4 5 6 7 14 13 12 11 10 9 8 15 16 17 18 19 20 21 22 23 4x6 4x6 5x6 5x8 3x4 4x6 3x6 5x6 5x12 3x4 3x4 4x9 5x8 MT20H 5x6 0-0-6 0-0-6 4-0-0 3-11-10 8-9-10 4-9-10 15-3-0 6-5-6 21-8-6 6-5-6 28-5-4 6-8-14 4-0-0 4-0-0 7-3-6 3-3-6 8-9-10 1-6-4 15-3-0 6-5-6 21-8-6 6-5-6 28-5-4 6-8-14 4-2-2 8-11-11 10-2-15 3-3-0 10.00 12 3.50 12 Plate Offsets (X,Y): [1:0-2-12,0-1-8], [4:0-2-0,0-3-4], [6:0-4-0,0-3-4], [7:0-3-0,0-2-0], [8:0-3-8,Edge], [9:0-3-8,0-2-0], [13:0-3-0,0-1-12] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15NOIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.960.570.85 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.17-0.280.06 (loc) 10-1210-128 l/defl >999>999n/a L/d 240180n/a PLATES MT20MT20H Weight: 160 lb FT = 10% GRIP 197/144148/108 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5E *Except* T4: 2 X 4 SPF 2100F 1.8EBOT CHORD 2 X 4 SPF 1650F 1.5E WEBS 2 X 4 SPF Stud *Except* W5,W7,W1,W12,W11: 2 X 4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied, except end verticals.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 4-12, 5-12 REACTIONS (lb/size)14 =1913/0-7-0 (min. 0-3-0)8 =2180/0-5-8 (min. 0-3-7) Max Horz 14 =-220(LC 6) Max Uplift 14 =-213(LC 7)8 =-320(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD1-15=-1318/167, 15-16=-1198/171, 2-16=-1161/179, TOP CHORD1-15=-1318/167, 15-16=-1198/171, 2-16=-1161/179, 2-17=-1588/268, 3-17=-1434/284, 3-4=-1966/419, 4-18=-1421/295, 18-19=-1523/294, 5-19=-1656/282, 5-6=-2541/406, 6-20=-2343/377, 20-21=-2454/368, 7-21=-2565/368, 1-14=-1882/228, 7-8=-2115/347 BOT CHORD13-22=-80/940, 12-22=-80/940, 11-12=-253/2327, 10-11=-253/2327, 10-23=-319/2374, 9-23=-319/2374WEBS2-13=-798/136, 2-12=-97/453, 3-12=-443/2043, 4-12=-1272/289, 5-12=-1298/281, 5-10=0/281, 6-9=-857/208, 1-13=-128/1327, 7-9=-328/2495 NOTES (14) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Automatic zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) All plates are MT20 plates unless otherwise indicated. 5) The solid section of the plate is required to be placed over the splice line at joint(s) 6. 6) Plate(s) at joint(s) 6 checked for a plus or minus 1 degree rotation about its center. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.8) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.9) All bearings are assumed to be SPF No.2 . 10) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 213 lb uplift at joint 14 and 320 lb uplift at joint 8.11) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Load case(s) 1, 2, 3, 12, 13, 14, 15 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 13) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 14) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard1) Snow: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-3=-82, 3-4=-82, 4-7=-132, 13-14=-20, 13-22=-60, 11-22=-20, 10-11=-60, 10-23=-20, 9-23=-60, 8-9=-20 2) Unbal.Snow-Left: Lumber Increase=1.15, Plate Increase=1.15Continued on page 2 Job Q1103376 Truss T12C Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:43:18 2011 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-A5LK9FKVABmodLFWKNTjtI6ebudbNihEPn82gAzB?jd LOAD CASE(S)StandardUniform Loads (plf)Vert: 1-15=-82, 3-15=-140, 3-4=-38, 4-7=-88, 13-14=-20, 13-22=-60, 11-22=-20,10-11=-60, 10-23=-20, 9-23=-60, 8-9=-203) Unbal.Snow-Right: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-38, 3-4=-106, 4-18=-156, 7-18=-132, 13-14=-20, 13-22=-60, 11-22=-20, 10-11=-60, 10-23=-20, 9-23=-60, 8-9=-20 12) 3rd Unbal.Snow-Left: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-3=-38, 3-4=-113, 4-7=-88, 13-14=-20, 13-22=-60, 11-22=-20, 10-11=-60,10-23=-20, 9-23=-60, 8-9=-2013) 4th Unbal.Snow-Left: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-15=-82, 3-15=-140, 3-4=-38, 4-7=-88, 13-14=-20, 13-22=-60, 11-22=-20,10-11=-60, 10-23=-20, 9-23=-60, 8-9=-2014) 5th Unbal.Snow-Right: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-38, 3-4=-106, 4-7=-88, 13-14=-20, 13-22=-60, 11-22=-20, 10-11=-60, 10-23=-20, 9-23=-60, 8-9=-20 15) 6th Unbal.Snow-Right: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf)Vert: 1-3=-38, 3-4=-38, 4-19=-149, 7-19=-132, 13-14=-20, 13-22=-60, 11-22=-20,10-11=-60, 10-23=-20, 9-23=-60, 8-9=-20 Job Q1103376 Truss T12D Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:43:12 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-Mx_3vCFkaL?evQnM_6MJd1seJTaIzy5M1shkTWzB?jj Scale = 1:60.2 T1 T2 T3 B1 W3 W4 W5 W6 W7 W8 W9 W10W2W1 W12W11 T4 B2 1 2 3 4 5 6 7 14 13 12 11 10 9 8 15 16 17 18 19 20 21 22 23 4x6 4x6 5x6 5x8 3x4 4x6 3x6 5x6 5x12 3x4 3x4 4x9 5x8 MT20H 5x6 0-0-6 0-0-6 4-0-0 3-11-10 8-4-3 4-4-3 14-9-9 6-5-6 21-2-15 6-5-6 27-11-13 6-8-14 4-0-0 4-0-0 6-9-15 2-9-15 8-4-3 1-6-4 14-9-9 6-5-6 21-2-15 6-5-6 27-11-13 6-8-14 4-6-10 8-11-11 10-2-15 3-3-0 10.00 12 3.50 12 Plate Offsets (X,Y): [1:0-2-12,0-1-8], [4:0-2-0,0-3-4], [6:0-4-0,0-3-4], [7:0-3-0,0-2-0], [8:0-3-8,Edge], [9:0-3-8,0-2-0], [13:0-3-0,0-1-12] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15NOIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.950.560.98 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.16-0.270.06 (loc) 10-1210-128 l/defl >999>999n/a L/d 240180n/a PLATES MT20MT20H Weight: 160 lb FT = 10% GRIP 197/144148/108 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5E *Except* T4: 2 X 4 SPF 2100F 1.8EBOT CHORD 2 X 4 SPF 1650F 1.5E WEBS 2 X 4 SPF Stud *Except* W5,W7,W1,W12,W11: 2 X 4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied, except end verticals.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 4-12, 5-12 REACTIONS (lb/size)14 =1890/0-7-0 (min. 0-2-15)8 =2149/0-5-8 (min. 0-3-6) Max Horz 14 =-218(LC 6) Max Uplift 14 =-214(LC 7)8 =-315(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD1-15=-1240/163, 15-16=-1144/164, 2-16=-1084/174, TOP CHORD1-15=-1240/163, 15-16=-1144/164, 2-16=-1084/174, 2-17=-1501/263, 3-17=-1368/277, 3-4=-1879/407, 4-18=-1348/284, 18-19=-1451/282, 5-19=-1584/274, 5-6=-2479/396, 6-20=-2300/370, 20-21=-2411/362, 7-21=-2522/362, 1-14=-1856/230, 7-8=-2084/342 BOT CHORD13-22=-66/879, 12-22=-66/879, 11-12=-244/2268, 10-11=-244/2268, 10-23=-313/2332, 9-23=-313/2332WEBS2-13=-836/137, 2-12=-99/500, 3-12=-437/1960, 4-12=-1234/286, 5-12=-1309/283, 5-10=0/295, 6-9=-838/205, 1-13=-128/1303, 7-9=-320/2450 NOTES (13) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Automatic zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) All plates are MT20 plates unless otherwise indicated. 5) The solid section of the plate is required to be placed over the splice line at joint(s) 6. 6) Plate(s) at joint(s) 6 checked for a plus or minus 1 degree rotation about its center. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.8) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.9) All bearings are assumed to be SPF No.2 . 10) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 214 lb uplift at joint 14 and 315 lb uplift at joint 8.11) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 13) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard1) Snow: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-3=-82, 3-4=-82, 4-7=-132, 13-14=-20, 13-22=-60, 11-22=-20, 10-11=-60,10-23=-20, 9-23=-60, 8-9=-20 Job Q1103376 Truss T12E Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:43:04 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-bOV1DT9jTu?nyBAqWRCRJLXG5FrJ5LAABclJB_zB?jr Scale = 1:62.3 T1 T2 T3 B1 W3 W4 W5 W6 W7 W8 W2 W1 W10W9 T4 B2 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 17 18 19 20 3x6 7x10 MT18H 5x6 4x12 3x8 3x6 5x8 3x4 3x4 3x4 4x9 3x12 MT20H 6x6 0-0-6 0-0-6 6-4-3 6-3-13 12-9-9 6-5-6 19-2-15 6-5-6 25-11-13 6-8-14 4-9-15 4-9-15 6-4-3 1-6-4 12-9-9 6-5-6 19-2-15 6-5-6 25-11-13 6-8-14 6-2-108-11-11 10-2-15 3-3-0 10.00 12 3.50 12 Plate Offsets (X,Y): [3:0-2-0,0-3-0], [6:0-6-0,Edge], [9:0-3-8,0-2-0], [12:0-3-0,0-1-12] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15NOIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.900.570.98 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.14-0.220.05 (loc) 10-1210-128 l/defl >999>999n/a L/d 240180n/a PLATES MT20MT20HMT18HWeight: 145 lb FT = 10% GRIP 197/144148/108197/144 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5E *Except* T4: 2 X 4 SPF 2100F 1.8EBOT CHORD 2 X 4 SPF 1650F 1.5E WEBS 2 X 4 SPF No.2 *Except* W4,W6,W7,W8,W9: 2 X 4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 3-1-15 oc purlins, except end verticals.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 3-12, 4-12, 2-13 REACTIONS (lb/size)13 =1867/0-7-0 (min. 0-2-15)8 =2020/0-5-8 (min. 0-3-3) Max Horz 13 =-213(LC 6) Max Uplift 13 =-225(LC 7)8 =-290(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-14=-1518/330, 3-14=-1535/324, 3-15=-1173/227, TOP CHORD2-14=-1518/330, 3-14=-1535/324, 3-15=-1173/227, 4-15=-1307/220, 4-5=-2221/347, 5-16=-2131/337, 6-16=-2196/332, 6-17=-2239/329, 7-17=-2349/329, 1-13=-337/129, 7-8=-1956/317 BOT CHORD 13-18=0/760, 18-19=0/760, 12-19=0/760, 11-12=-198/2020, 10-11=-198/2020, 10-20=-277/2151, 9-20=-277/2151WEBS2-12=-395/2341, 3-12=-1086/242, 4-12=-1332/299, 4-10=-2/323, 5-9=-760/193, 2-13=-1731/189, 7-9=-287/2272 NOTES (13)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Automatic zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) All plates are MT20 plates unless otherwise indicated. 5) The solid section of the plate is required to be placed over the splice line at joint(s) 11.6) Plate(s) at joint(s) 11 checked for a plus or minus 2 degree rotation about its center. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.8) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.9) All bearings are assumed to be SPF No.2 . 10) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 225 lb uplift at joint 13 and 290 lb uplift at joint 8.11) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 13) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard1) Snow: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-2=-82, 2-3=-82, 3-7=-132, 13-18=-20, 18-19=-60, 11-19=-20, 10-11=-60,10-20=-20, 9-20=-60, 8-9=-20 Job Q1103376 Truss T12F Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:43:00 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-idGXO56CPfULTat3Hb8V8VMbYePM9YlbG_n52DzB?jv Scale = 1:58.0 T1 T2 T3 B1 W3 W4 W5 W6 W7 W2 W1 W9 W8 T4 B2 1 2 3 4 5 6 7 12 11 10 9 8 13 14 15 16 17 18 19 20 2x4 6x9 5x9 4x12 3x6 4x9 5x8 3x4 3x4 4x4 3x8 5x6 0-0-6 0-0-6 4-4-3 4-3-13 14-0-4 9-8-1 23-11-13 9-11-9 2-9-15 2-9-15 4-4-3 1-6-4 10-9-9 6-5-6 17-2-15 6-5-6 23-11-13 6-8-14 7-10-10 8-11-11 10-2-15 3-3-0 10.00 12 3.50 12 Plate Offsets (X,Y): [6:0-6-0,Edge], [11:0-3-0,0-1-12] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15NOIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.870.890.94 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.32-0.530.06 (loc) 9-119-118 l/defl >893>538n/a L/d 240180n/a PLATES MT20 Weight: 135 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5EBOT CHORD 2 X 4 SPF 1650F 1.5EWEBS2 X 4 SPF No.2 *Except* W4,W6,W7,W8: 2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 4-0-12 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 3-11, 4-11, 2-12, 1-12, 5-8 REACTIONS (lb/size)12 =1796/0-7-0 (min. 0-2-13)8 =1913/0-5-8 (min. 0-3-0)Max Horz 12 =-208(LC 6) Max Uplift 12 =-241(LC 7) 8 =-260(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-3=-1153/251, 3-13=-805/155, 4-13=-980/148, 4-5=-2138/308, TOP CHORD2-3=-1153/251, 3-13=-805/155, 4-13=-980/148, 4-5=-2138/308, 7-8=-409/117 BOT CHORD 12-16=0/454, 16-17=0/454, 11-17=0/454, 10-11=-146/1741, 10-18=-146/1741, 9-18=-146/1741, 9-19=-254/1962, 19-20=-254/1962, 8-20=-254/1962WEBS2-11=-389/2261, 3-11=-939/223, 4-11=-1373/326, 4-9=-33/467, 2-12=-1720/212, 5-8=-2333/308 NOTES (11)1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) interior zone and C-C Automatic zone; cantilever left andright exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf. 6) All bearings are assumed to be SPF No.2 . 7) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 241 lb uplift at joint 12 and 260 lb uplift at joint 8.8) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.9) Load case(s) 1, 2, 3, 12, 13, 14, 15 has/have been modified. Building designer mustreview loads to verify that they are correct for the intended use of this truss.10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 11) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard 1) Snow: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-2=-82, 2-3=-82, 3-7=-132, 12-16=-20, 16-17=-60, 10-17=-20, 10-18=-60,18-19=-20, 19-20=-60, 8-20=-202) Unbal.Snow-Left: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-2=-140, 2-3=-38, 3-7=-88, 12-16=-20, 16-17=-60, 10-17=-20, 10-18=-60,18-19=-20, 19-20=-60, 8-20=-203) Unbal.Snow-Right: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Continued on page 2 Job Q1103376 Truss T12F Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:43:00 2011 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-idGXO56CPfULTat3Hb8V8VMbYePM9YlbG_n52DzB?jv LOAD CASE(S)StandardUniform Loads (plf)Vert: 1-2=-38, 2-3=-82, 3-7=-132, 12-16=-20, 16-17=-60, 10-17=-20, 10-18=-60,18-19=-20, 19-20=-60, 8-20=-2012) 3rd Unbal.Snow-Left: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-38, 2-3=-113, 3-7=-88, 12-16=-20, 16-17=-60, 10-17=-20, 10-18=-60, 18-19=-20, 19-20=-60, 8-20=-20 13) 4th Unbal.Snow-Left: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-2=-140, 2-3=-38, 3-7=-88, 12-16=-20, 16-17=-60, 10-17=-20, 10-18=-60,18-19=-20, 19-20=-60, 8-20=-2014) 5th Unbal.Snow-Right: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-2=-38, 2-3=-82, 3-7=-88, 12-16=-20, 16-17=-60, 10-17=-20, 10-18=-60,18-19=-20, 19-20=-60, 8-20=-2015) 6th Unbal.Snow-Right: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-38, 2-3=-38, 3-13=-139, 7-13=-132, 12-16=-20, 16-17=-60, 10-17=-20, 10-18=-60, 18-19=-20, 19-20=-60, 8-20=-20 Job Q1103376 Truss T12G Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:42:49 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-XW5M4L_J?H6vfuXx8nRwCAPjZCfJ5anzknd0AMzB?k4 Scale = 1:53.9 W1 T1 T3 B2 W2 W3 W4 W5 W6 W8 W7 B1 T2 1 2 3 4 5 9 8 7 6 10 11 12 13 14 15 16 3x8 1.5x4 6x6 5x6 6x9 4x6 3x4 6x9 3x8 1-8-7 1-8-7 11-4-8 9-8-1 21-4-0 9-11-9 1-8-7 1-8-7 8-1-13 6-5-6 14-7-3 6-5-6 21-4-0 6-8-14 10-4-12 8-11-11 3-3-0 10.00 12 3.50 12 SKHH28L (USP) FROM 2X8 HEADER Plate Offsets (X,Y): [4:0-3-12,Edge], [7:0-4-8,Edge] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15NOIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.860.860.96 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.29-0.510.05 (loc) 7-86-76 l/defl >873>497n/a L/d 240180n/a PLATES MT20 Weight: 118 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5E *Except* T2: 2 X 4 SPF 2100F 1.8EBOT CHORD 2 X 4 SPF 1650F 1.5E WEBS 2 X 4 SPF Stud *Except* W1,W4,W8: 2 X 4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 4-10-14 oc purlins, except end verticals.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 1-9, 2-9, 3-8, 4-6 REACTIONS (lb/size)9 =1722/Mechanical6 =1706/0-5-8 (min. 0-2-12) Max Horz 9 =-251(LC 7) Max Uplift 9 =-274(LC 7)6 =-207(LC 7)Max Grav9 =1944(LC 3)6 =1759(LC 3) Max Grav9 =1944(LC 3) 6 =1759(LC 3) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-10=-412/30, 3-10=-577/16, 3-4=-1871/216, 5-6=-414/117BOT CHORD8-9=0/373, 8-13=-43/1453, 13-14=-43/1453, 7-14=-43/1453, 7-15=-183/1759, 15-16=-183/1759, 6-16=-183/1759WEBS2-9=-2085/293, 2-8=-166/1416, 3-8=-1556/351, 3-7=-67/585, 4-6=-2073/219 NOTES (12) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Automatic zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.6) All bearings are assumed to be SPF No.2 . 7) Refer to girder(s) for truss to truss connections.8) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 274 lb uplift at joint 9 and 207 lb uplift at joint 6.9) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.10) Load case(s) 1, 2, 3 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 12) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard1) Snow: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-2=-132, 2-5=-132, 9-13=-20, 13-14=-60, 14-15=-20, 15-16=-60, 6-16=-202) Unbal.Snow-Left: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf) Vert: 1-2=-88, 2-5=-88, 9-13=-20, 13-14=-60, 14-15=-20, 15-16=-60, 6-16=-20 3) Unbal.Snow-Right: Lumber Increase=1.15, Plate Increase=1.15Continued on page 2 Job Q1103376 Truss T12G Truss Type Special Truss Qty 1 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:42:49 2011 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-XW5M4L_J?H6vfuXx8nRwCAPjZCfJ5anzknd0AMzB?k4 LOAD CASE(S)StandardUniform Loads (plf)Vert: 1-2=-166, 2-3=-166, 3-5=-132, 9-13=-20, 13-14=-60, 14-15=-20, 15-16=-60,6-16=-20 Job Number: This non‐structural placement plan is provided for identifying the location of trusses as supplied by Truss Engineering Corporation (TEC). No responsibility is taken or implied by TEC for the structural integrity of the structure below the trusses or the affects of TEC’s product on the structure as a whole. The truss installer shall follow all BCSI recommendations, construction document specifications as well as any site specific requirements to ensure safe and proper installation. No loading shall be applied to trusses until properly and fully installed, including all sheathing, hangers, wall anchors, lateral web bracing (as shown on individual shop drawings), and permanent bracing (as required by the construction documents). Installation contractor shall refer to the individual truss shop drawings for all structural requirements of trusses, including but not limited to bearing locations and requirements, ply to ply nailing, lateral web bracing, and truss spacing. Truss Engineering Corporation strictly adheres to the ‘Standard Responsibilities in the Design of Metal Plate Connected Wood Trusses’ as defined by TPI Chapter 2 (available upon request) regardless of any job specific specifications unless clearly defined otherwise in writing by TEC. This placement plan is Truss Engineering Corporation’sINTERPRETATION of plans and drawings as supplied to us. The building owner/owner’s agent is solely responsible for verifying all dimensions, geometry, loads and load requirements for accuracy and full compliance to construction documents and shall be responsible for notifying TEC immediately of any discrepancies. The building owner/owner’s agent is responsible for coordinating all construction details between trades. Truss Engineering Corporation isNOT responsible for field verification of dimensions or special conditions. No trusses supplied by Truss Engineering Corporation may be cut, drilled, or altered in any way without first contacting TEC and receiving engineering documents allowing such. Quote Number: Q1103376 Drawn By: Brian Tetreault Job Name: Jobsite: GREER HELMUTHRESIDENCE JEFFREY BOTT CONTRACTING 158 BAKER HILL ROAD EXT. NORTHAMPTONMA Job Q1103376 Truss 20 Truss Type Jack-Closed Truss Qty 8 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 13:00:26 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-jgUrc5tkYXtltFhQn9CWVB46A?Su3yk80GoJ9QzCIzJ Scale = 1:25.1 W1 T1 W2 B1 1 2 3 5 4 3x4 3x4 3x4 2x4 5-3-11 5-3-11 -1-4-0 1-4-0 5-3-11 5-3-11 1-0-0 4-1-2 4-2-9 7.00 12 LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLLBCDL 30.8 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.35 0.200.00 DEFL Vert(LL) Vert(TL)Horz(TL) in -0.02 -0.060.00 (loc) 4-5 4-54 l/defl >999 >930n/a L/d 240 180n/a PLATES MT20 Weight: 20 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF No.2 *Except* W2: 2 X 4 SPF StudBRACING TOP CHORD Structural wood sheathing directly applied or 5-3-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)5 =393/0-5-8 (min. 0-1-8)4 =237/MechanicalMax Horz5 =158(LC 8)Max Uplift5 =-73(LC 8) 4 =-92(LC 8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD2-5=-355/133 NOTES (12) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever leftand right exposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members.7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 73 lb uplift at joint 5 and 92 lb uplift at joint 4.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss 21 Truss Type Jack-Open Truss Qty 8 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 13:06:18 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-POmwUS8XfhEo6Mb4P5W3mQfJ0vd4Y8tyz13xV1zCItp Scale = 1:16.6 W1 T1 B1 1 2 5 3 4 2x4 3x4 3-3-11 3-3-11 -1-4-0 1-4-0 3-3-11 3-3-11 1-0-0 2-11-2 3-0-9 2-6-4 7.00 12 LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLLBCDL 30.8 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.18 0.080.00 DEFL Vert(LL) Vert(TL)Horz(TL) in 0.01 -0.01-0.01 (loc) 4-5 4-53 l/defl >999 >999n/a L/d 240 180n/a PLATES MT20 Weight: 11 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF No.2BRACING TOP CHORD Structural wood sheathing directly applied or 3-3-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)5 =307/0-5-8 (min. 0-1-8)3 =99/Mechanical4 =29/MechanicalMax Horz5 =115(LC 8)Max Uplift5 =-71(LC 8) 3 =-58(LC 8) Max Grav 5 =307(LC 1) 3 =99(LC 1)4 =57(LC 4) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-5=-274/117 TOP CHORD2-5=-274/117 NOTES (12) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members. 7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 71 lb uplift at joint 5 and 58 lb uplift at joint 3.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 12) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss 22 Truss Type Jack-Open Truss Qty 8 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 13:03:41 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-WBmZYnE2dSS4mD5vicCFvJfUec2tF80rs6X7VdzCIwG Scale = 1:11.1 W1 T1 B1 1 2 5 3 4 1.5x4 3x4 1-3-11 1-3-11 -1-4-0 1-4-0 1-3-11 1-3-11 1-0-0 1-9-2 1-10-9 1-4-4 7.00 12 LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLLBCDL 30.8 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.18 0.050.00 DEFL Vert(LL) Vert(TL)Horz(TL) in 0.00 0.00-0.00 (loc) 5 53 l/defl >999 >999n/a L/d 240 180n/a PLATES MT20 Weight: 6 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF No.2BRACING TOP CHORD Structural wood sheathing directly applied or 1-3-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)5 =257/0-5-8 (min. 0-1-8)4 =-8/Mechanical3 =-11/MechanicalMax Horz5 =72(LC 8)Max Uplift5 =-82(LC 8) 4 =-11(LC 12) 3 =-44(LC 12) Max Grav 5 =257(LC 1)4 =17(LC 4)3 =12(LC 6) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES (12) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever leftand right exposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members.7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 82 lb uplift at joint 5, 11 lb uplift at joint 4 and 44 lb uplift at joint 3.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss 23 Truss Type Jack-Closed Truss Qty 6 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 13:03:27 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-wVwGc_4Gw8h3540DugyzLM43IzABzolnex8O?RzCIwU Scale: 3/8"=1' W1 T1 W3 B1 W2 1 2 3 4 6 5 7 8 9 3x4 4x4 2x4 4x4 1.5x4 7-4-12 7-4-12 -1-4-0 1-4-0 3-8-6 3-8-6 7-4-12 3-8-6 1-0-0 5-3-12 5-5-2 7.00 12 Plate Offsets (X,Y): [2:0-2-0,0-1-12] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15YESIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.300.390.12 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.09-0.230.00 (loc) 5-65-65 l/defl >897>372n/a L/d 240180n/a PLATES MT20 Weight: 31 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W1: 2 X 4 SPF No.2BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)6 =494/0-5-8 (min. 0-1-8)5 =348/MechanicalMax Horz6 =196(LC 8)Max Uplift 6 =-82(LC 8) 5 =-110(LC 8) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-6=-415/126, 2-7=-332/3WEBS3-5=-251/161 WEBS3-5=-251/161 NOTES (12) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -1-4-0 to 1-8-0, Interior(1) 1-8-0 to 3-0-1, Exterior(2) 3-0-1 to 7-3-0 zone; cantilever left and rightexposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members.7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 82 lb uplift at joint 6 and 110 lb uplift at joint 5. 10) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard Job Q1103376 Truss CJ4 Truss Type Diagonal Hip Girder Qty 4 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 13:05:59 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-Tk6kVzvc7rqVKReQnbgcVPN?pE2fbPg9bayRLdzCIu6 Scale = 1:32.4 W1 T1 W5 B1W2 W3 W4 1 2 3 4 7 6 5 8 9 10 11 12 13 2x4 3x4 1.5x4 4x4 4x4 3x4 Nailed Nailed Nailed Nailed SUL26 Nailed Nailed Nailed Nailed SUR26 5-2-0 5-2-0 10-4-0 5-2-0 -1-10-10 1-10-10 5-2-0 5-2-0 10-4-0 5-2-0 1-0-0 5-3-2 5-4-4 4.95 12 LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLLBCDL 30.8 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15NOIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.43 0.460.61 DEFL Vert(LL) Vert(TL)Horz(TL) in -0.04 -0.090.00 (loc) 5-6 5-65 l/defl >999 >999n/a L/d 240 180n/a PLATES MT20 Weight: 53 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 6 SPF 1650F 1.5EWEBS2 X 4 SPF Stud *Except* W1: 2 X 4 SPF No.2BRACING TOP CHORD Structural wood sheathing directly applied or 5-9-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)7 =768/0-7-6 (min. 0-1-8)5 =826/MechanicalMax Horz7 =194(LC 7)Max Uplift7 =-231(LC 7) 5 =-285(LC 7) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD2-7=-778/250, 2-8=-932/205, 8-9=-809/226, 3-9=-780/205BOT CHORD6-13=-304/800, 5-13=-304/800WEBS2-6=-161/808, 3-6=-66/334, 3-5=-912/346 WEBS2-6=-161/808, 3-6=-66/334, 3-5=-912/346 NOTES (17) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members. 7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 231 lb uplift at joint 7 and 285 lb uplift at joint 5.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) Use Simpson Strong-Tie SUL26 (6-10d Girder, 6-10dx1 1/2 Truss, Single Ply Girder) or equivalent at 7-7-2 from the left end to connect truss(es) 20 (1 ply 2 X 4 SPF) to front face of bottom chord, skewed 45.0 deg.to the left, sloping 0.0 deg. down. 13) Use Simpson Strong-Tie SUR26 (6-10d Girder, 6-10dx1 1/2 Truss, Single PlyGirder) or equivalent at 7-7-2 from the left end to connect truss(es) 20 (1 ply 2 X 4 SPF) to back face of bottom chord, skewed 45.0 deg.to the right, sloping 0.0 deg. down. 14) Fill all nail holes where hanger is in contact with lumber.15) "Nailed" indicates 3-10d or 2-12d common wire toe-nails. For more details refer toMiTek's ST-TOENAIL Detail. 16) In the LOAD CASE(S) section, loads applied to the face of the truss are noted asfront (F) or back (B). 17) All Plates 20 Gauge Unless Noted LOAD CASE(S) Standard1) Snow: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-2=-82, 2-4=-82, 5-7=-20Concentrated Loads (lb)Vert: 8=44(F=22, B=22) 9=-35(F=-18, B=-18) 11=36(F=18, B=18) 12=-19(F=-9, B=-9)13=-434(F=-217, B=-217) Job Q1103376 Truss G20 Truss Type Hip Truss Qty 2 Ply 2 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 13:13:15 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-idSZ02B6SpmdeRzDKAVsAMRYw?ulleJKrPaVeMzCInI Scale: 3/8"=1' T1 T2 T1 B1 W3 W4 W5 W4 W3 W1 W2 W1 W2 1 2 3 4 5 6 7 8 12 11 10 9 13 14 15 16 17 4x4 4x9 3x8 4x4 4x4 4x4 8x9 8x9 THJA26 LUS26 THJA26 7-4-12 7-4-12 11-4-12 4-0-0 18-9-8 7-4-12 -1-4-0 1-4-0 3-10-2 3-10-2 7-4-12 3-6-10 11-4-12 4-0-0 14-11-6 3-6-10 18-9-8 3-10-2 20-1-8 1-4-0 1-0-0 5-3-12 5-5-2 1-0-0 5-3-12 7.00 12 Plate Offsets (X,Y): [2:Edge,0-2-12], [5:0-6-8,0-2-0], [7:Edge,0-2-12] LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLL BCDL 30.8 10.00.0 * 10.0 SPACING Plates IncreaseLumber IncreaseRep Stress IncrCode 2-0-0 1.151.15NOIRC2009/TPI2007 CSI TCBCWB(Matrix) 0.290.260.44 DEFL Vert(LL)Vert(TL)Horz(TL) in -0.06-0.100.03 (loc) 10-1110-119 l/defl >999>999n/a L/d 240180n/a PLATES MT20 Weight: 198 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 6 SPF 1650F 1.5EWEBS2 X 4 SPF Stud *Except* W1: 2 X 4 SPF No.2BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)12 =2359/0-5-8 (min. 0-2-3)9 =2359/0-5-8 (min. 0-2-3)Max Horz12 =-125(LC 5) Max Uplift 12 =-670(LC 7) 9 =-670(LC 8) Max Grav12 =2764(LC 17)9 =2764(LC 17) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD2-13=-631/136, 3-13=-452/150, 3-14=-3511/958, 4-14=-3352/966, 4-5=-2955/871, 5-15=-3344/964, 6-15=-3503/956, 6-16=-459/152, 7-16=-638/138, 2-12=-742/202, 7-9=-745/203 BOT CHORD 11-12=-764/2905, 11-17=-749/2947, 10-17=-749/2947, 9-10=-691/2901WEBS3-11=-176/319, 4-11=-410/1387, 5-10=-420/1377, 6-10=-175/315,3-12=-3151/814, 6-9=-3137/810 NOTES (19)1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc.Bottom chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc. Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.3) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; LumberDOL=1.33 plate grip DOL=1.334) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-0 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 30.8 psf on overhangs non-concurrent with other live loads.7) Provide adequate drainage to prevent water ponding.8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.9) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.10) All bearings are assumed to be SPF No.2 . 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 670 lb uplift at joint 12 and 670 lb uplift at joint 9. 12) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.13) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 14) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened totruss TC w/ 2-10d nails.15) Use Simpson Strong-Tie THJA26 (THJA26 on 2 ply, Left Hand Hip) or equivalent at7-5-2 from the left end to connect truss(es) 23 (1 ply 2 X 4 SPF), CJ4 (1 ply 2 X 6 SPF) to front face of bottom chord, skewed 0.0 deg.to the left, sloping 0.0 deg. down. 16) Use Simpson Strong-Tie LUS26 (4-10d Girder, 3-10d Truss, Single Ply Girder) or equivalent at 9-4-12 from the left end to connect truss(es) 23 (1 ply 2 X 4 SPF) to front face of bottom chord, skewed 0.0 deg.to the left, sloping 0.0 deg. down. Continued on page 2 Job Q1103376 Truss G20 Truss Type Hip Truss Qty 2 Ply 2 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Fri May 27 13:13:16 2011 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-Ap0xDOCkD7uUFbYPut05jZzjgPE_U5ZU43J3BozCInH NOTES (19) 17) Use Simpson Strong-Tie THJA26 (THJA26 on 2 ply, Right Hand Hip) or equivalent at 11-4-6 from the left end to connect truss(es) 23 (1 ply 2 X 4 SPF), CJ4 (1 ply 2 X 6 SPF) to front face of bottom chord, skewed 0.0 deg.to the left, sloping 0.0 deg. down. 18) Fill all nail holes where hanger is in contact with lumber.19) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard1) Snow: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-2=-82, 2-4=-82, 4-5=-82, 5-7=-82, 7-8=-82, 9-12=-20 Concentrated Loads (lb) Vert: 11=-1134(F) 10=-1134(F) 17=-328(F) Job Q1103376 Truss T20 Truss Type Common Truss Qty 4 Ply 1 158 BAKER HILL RD. EXT. NORTHAMPTON, MA Job Reference (optional)7.250 s Nov 19 2010 MiTek Industries, Inc. Tue May 31 11:39:55 2011 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:sXWZz8gHvaHPARqXs5Hhk_zCKZa-d1abZrtAzqBbn8EVxEJ68UC6u3InJxYMkiTp2RzB?mo Scale = 1:37.3 T1 T1 B1 W4 W3W3 W1 W2 W1 W2 1 2 3 4 5 6 7 10 9 8 11 12 13 14 15 16 4x4 3x8 4x4 4x4 3x4 3x6 3x4 3x6 9-4-12 9-4-12 18-9-8 9-4-12 -1-4-0 1-4-0 4-10-2 4-10-2 9-4-12 4-6-10 13-11-6 4-6-10 18-9-8 4-10-2 20-1-8 1-4-0 1-0-0 6-5-12 6-7-2 1-0-0 7.00 12 LOADING (psf)TCLL(Ground Snow=40.0)TCDLBCLLBCDL 30.8 10.00.0 *10.0 SPACING Plates Increase Lumber IncreaseRep Stress IncrCode 2-0-0 1.15 1.15YESIRC2009/TPI2007 CSI TC BCWB(Matrix) 0.38 0.720.65 DEFL Vert(LL) Vert(TL)Horz(TL) in -0.14 -0.370.03 (loc) 9-10 9-108 l/defl >999 >604n/a L/d 240 180n/a PLATES MT20 Weight: 83 lb FT = 10% GRIP 197/144 LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W1: 2 X 4 SPF No.2BRACING TOP CHORD Structural wood sheathing directly applied or 5-10-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)10 =1060/0-5-8 (min. 0-1-11)8 =1061/0-5-8 (min. 0-1-11)Max Horz10 =-159(LC 6)Max Uplift10 =-194(LC 8) 8 =-194(LC 9) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD2-11=-317/65, 3-12=-949/160, 12-13=-880/165, 4-13=-847/178, 4-14=-847/178, 14-15=-880/165, 5-15=-949/160, 6-16=-317/65, 2-10=-422/172, 6-8=-422/172BOT CHORD9-10=-114/930, 8-9=-75/930 BOT CHORD9-10=-114/930, 8-9=-75/930WEBS 4-9=-56/496, 5-9=-307/161, 3-9=-307/160, 3-10=-925/159, 5-8=-925/159 NOTES (11) 1) Wind: ASCE 7-05; 100mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -1-4-0 to 1-8-0,Interior(1) 1-8-0 to 6-4-12, Exterior(2) 6-4-12 to 9-4-12, Interior(1) 12-4-12 to 17-1-8zone; cantilever left and right exposed ;C-C for members and forces & MWFRS forreactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 40.0 psf (ground snow); Pf=30.8 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 30.8 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.7) All bearings are assumed to be SPF No.2 . 8) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 194 lb uplift at joint 10 and 194 lb uplift at joint 8. 9) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 11) All Plates 20 Gauge Unless Noted LOAD CASE(S)Standard