Loading...
approval letterJune3, 2011 additionJune 3, 2011 Roger Clark PO Box 34 Leeds, MA 01053 Subject Property: 240 Spring Street Florence, MA 01062 Mr. Clark, The plans for the Single Family Residential addition dated 4-4-11 have been approved as noted; Structure conforms to 780 CMR 7th addition 1 and 2 family building codes. Energy aspects must comply with 2009 IECC prescriptive and mandatory requirements or an appropriate HERS rating. Northampton has the stretch energy code. (appendix 120AA) If R-30 is used per Res Check it must be in substantial contact with the floor above and must be enclosed within a tight cavity. If spray foam or rigid is used on the basement walls there must be an ignition barrier. R-316.4 The entire structure will have smokes and COs updated. A smoke in each bedroom, a smoke and CO within 10’ of bedrooms, a smoke and CO at the bottom of each stair to a finished area. R-314 and R-315 Tempered glass must be used in all hazardous locations. (Windows on stair landing) R-308.4 Charles Miller Assistant Commissioner of Buildings