Loading...
17 fair Report Foundation System for Building Inspector 4-5-10Vreeland Design Associates An integrative approach to residential design,engineering and site planning Date:April 5,2010 To:Louis Hasbrouck Inspector of Buildings/Zoning Enforcement Northampton,MA 0 I 060 From:David Vreeland,P.E. Vreeland Design Associates Re:Elaine Yeskie,17 Fair St.,Northampton,MA:Construction in a flood plain of new home to replace existing home destroyed by fire. Dear Louis, I have been consulting with Jim Harrity in regards to the foundation requirements for the construction of a new home,at 17 Fair Street,for Elaine Yeskie,to replace the existing home destroyed by fire.The lot,as is most of Fair Street,is in the flood plain of the Connecticut River. The following is a summary of information for the proposed foundation: 1.The 100 Year Base Flood Elevation for this section of Fair Street is 125.0 feet with a flood hazard classification zone of A-13.See the attached section of the Flood Insurance Rate Map.I have marked the approximate location of the lot. 2.Richard Labarge,PLS,has prepared a Site Plan Sketch,dated 3/8/10,showing existing ground elevations with an apparent average ground elevation at the location of the proposed foundation to be 120.5'.See the attached copy of the Site Plan Sketch. 3.The enclosed area of the original house footprint was 1,198 sq.ft.See attached Assessor's Property Record Card.Based on photos from Google Earth,see attached photos for the north,west,and east elevations,of the original house and the topographic data from the Site Plan,it appears that the approximate elevation of the first floor was around 122.5'. The proposed enclosed area for the new house is 2,253 sq.ft.In accordance with 780 CMR:120.G501.4,the spaces below the Base Flood Elevation will not be used for human occupancy,except for the proposed garage area.See the attached Foundation Plan and Foundation Wall Detail.The garage area has an enclosed area of 552 sq.ft.and will have three (3)engineered SmartVent"flood vents installed,two vents in the east wall and one vent in the west wall.The crawlspace area has an enclosed area of 1,701 sq.ft. and will have nine (9)engineered Smart Vent"flood vents installed,two vent in the east wall,three vents in the south wall,and four vents in the west wall.The Smartv'ent" flood vents have been approved by FEMA to provide for 200 sq.ft.of enclosed area per vent.See the attached Engineered Flood Openings Certificate. 4.The short framed wall attached to the foundation and supporting the proposed house will be constructed with 2x6 pressure treated studs at 16"on center with Yz"plywood or OSB sheathing.The pressure treated sill plate will be bolted down with Yz"anchors at 4'-0" o.c.,and 12"maximum from comers and all ends of sill members. 5.The mechanical and electrical systems will be installed above the Base Flood Elevation. 116 River Road,Leyden,MA 01337 Email:dvreeland@verizon.net Phone:(413)624-0126 Fax:(413)624-3282 6.Since the enclosed area of the original house was not vented for flood waters there will be a net gain in terms of flood water storage volume with the proposed house.Assuming an average grade at the foundation of the original house at 121.0',an enclosed area of 1,198 sq.ft.,and with the base flood elevation =125.0',the loss of flood storage volume would have been 125.0'-121.0'=4'x 1,198 sq.ft.=4,792 cu.ft.gross volume.Assuming an approximate volume of 594 cu.ft.for the thickness of the original foundation,exterior and interior framed walls,the net loss of flood storage volume for the original house was approximately 4,792 sq.ft.-594 sq.ft.=4,198 cu.ft.Based on the proposed exterior grade at the new foundation,as well as the proposed elevation of the crawlspace slab = 121.4',and the garage slab at 121.30'to 121.55',the loss of flood storage volume due to foundation and framed walls,and exterior and garage stairs =260 cu.ft.Therefore,the approximate net gain in flood storage volume for the proposed house is:4,198 cu.ft. (original house net loss of flood storage volume)-260 cu.ft.(net loss proposed house)= 3,938 cu.ft. Based on the attached documentation,the proposed foundation system appears to be in compliance with 780 CMR:120.G501 FLOOD HAZARD ZONES. Please contact me if you have any questions or need additional information. Sincerely, David Vreeland,PE Vreeland Design Associates 2 APPROXIMATE SCALE 1000 a 1000 FEETi··..::::r-··..,,::::::::r ....t==--:::'f.--...-----.--.------, FLOOD INSURANCE RATE MAP CITY OF NORTHAMPTON, MASSACHUSETTS HAMPSHIRE COUNTY COMMUNITY·PANEL NUMBER2501670002A PAGE 2 OF 2 (SEE MAP INDEX FOR PAGES NOT P~INTEO) .'\l~'%I~'======================~.l~ us,DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT FEDERAL INSU RANCE ADMIN1STRATION../ d flood map.It Program flo This is an official copy of a portion of the above reference was extracted using F-MIT On-Line.This map does not reflect changes or amendments which may have been made subsequent to the date on the title block.For the latest product information about National Flood Insurance ad maps check the FEMA Flood Map Store at www.msc-fema.gov SKET<;;1'fIN 1'-.\0 R T I-{AM PT Of'.!/I\ \l1:;;-'Z..OI 03-oe:,-[ OW~Ed~:ELA INE YE.St<1 E lH:::+:."ZI~fa..\1 & #t-r F ArR,-{;TRE E T ~.SPIKE:1,,-1 POLE:4/3 /ELE:~1'Z.18'3 hfGVO'2. ,.SEe PL..Sk...\951 '?,G:..7('.Fo~ T eM;CH I S ~Ci?ON <:!oR SIDe.WAoLK E.LE.V:t2.+.'33 JJ.G~D.19'2~ /7J ::.,/;JyQjI J J~h/d"rf!. [1..0 •.l I.zi.4 r(~.c.t!) ,Lh :5) '1 :r'J\£~e-e:1)-<; ,I I lIB1.P. FWD ~II~~/18*1 Z,£Ep J'1E:A S _b(----;r" \ I.P.[:'1.1.,. c.oloLTauR I~n=~ I -s oN.E Foo 100 YEAR:FLo6DeU..eVt4TIOI\J ~rz.s.0 rtt.·j o'i\}<, .•...- 120.Go I2..D Northampton,MA Property Detail Page 1 of3 City of Northampton,MA:Residential Property Record Card New Search Property Type Classification Code Reference Card 1 of 1 Parcel -Location -Zoning -Assessment Map-Block-Lot:25C-256-001 Location:17 FAIR ST #Living Units:2 Class:R-I04 Zoning: Neigborhood:20 Deed Book:4323 Deed Page:118 Assessment: Land: Building: Total: 61,200 157,100 218,300 II Building Sketch 0/0 1 _Addition Information: 1///7 l--:='ENC.LOSED ~RE~~'I D,\/R..El='LA.t-.1t:>,PE: http://www.northamptonassessor.us/noho/propertydetail.php?map_no=25C..256-001&pagecard=1 Dwelling Information Style: Year Built: Story Height: Attic: Basement: Total Rooms: Bedrooms: Full Baths: Half Baths: Exterior Walls: Unfinished Area: Ground Floor Area: Total Living Area: Finished Basement Living Area: Basement Recreation Area: Woodburning Fireplace Stacks/Openings: Conventional 1900 2 None Full 8 4 2 o AlumNinyl o 971 2144 OXO OXO DescriptQrIArea' A:2Fr/9,,'971sqfl B:1Fr/B48sqft C:1tr/B1E;~rt D:OfP 294~qft E::EFPI1Fr/B138sqft .F:FUB.25sqft :I,196 .fT"Z. 4/5JIC> 3/9/2010 "oI-.:tru i 44'-6' 9 FLOOD VENTS --- REQUIRED FOR CRAWL SPACE TOP FOUNDATION WALL =122.15' CRAWLSPACE GRADE ELEV.=AVERAGE EXTERIOR GRADE RJ 121.4' NOTE:BOTTOM OF FLOOD VENTS MUST BE INSTALLED 12"OR LESS ABOVE FINALGRADE. "oI o(Y) -------SLAB AT BACK =121.55' '----3 FLOOD VENTS REQUIRED FORGARAGE 23'-OH 44'-6' "oIr-, Vreeland Design Associates an integrative approach to residential design,engineering, and site planning 116 River Rd.,Leyden,MA 01337 Contact:David Vreeland,PE Phone (413)624-0126 -Fax (413)624-3282 YESKIE RESIDENCE 17 FAIR STREET NORTHAMPTON,MA 01060 t TITLE:FOUNDATION-PLAN SK-1DATE:04.05.10 DRAWING NO.DRAWN:RTB CHECKED: SeAL£:1/8"-1'-0" wrfOM Cf FLOW vt:Nf -----2")(14"RIMJOISf ~FINISHfLOC\([l[V.~126.3' 14"TJI 100 YfPl([3AS['fLOOD a ~127.00' 12"PlYSHfA111ING------._--20 PJ.S1W @ 16"DC 8"x145" fNiAlNmfl?FlOOD vt:Nf ---2x6 p.r.PL-Aff ~fOP FOUNI?A11ON~122.17' flNPt.~~12\.4'~ Af OR PBOVf fXffRIOR aRAl?f ?"CONCRrif fLOOR 2-#4 [3P1( 8"?-B"ff'D5rWI"-JOOOP:l""""2-'"'' ~2-#4[3P1( ••2-#4 [3,AR Vreeland Design Associates an integrative approach to residential design,engineering, and site planning 116 River Rd.,Leyden,MA 01337 Contact:David Vreeland,PE Phone (413)624-0126 -Fax (413)624-3282 SK-2 YESKIE RESIDENCE 17 FAIR STREET NORTHAMPTON,MA 01060 TITLE:FOUNDATION-SECTION DRAWN:RTB CHECKED:DRAWING NO. DATE:04.05.10 SCAlE:1/2"=1'-0" 10.0 Engineered Flood Openings Certificate Engineered Flood Openings Certificate To satisfy requirements of the National Flood Insurance Program This certification must be submitted to,and kept on file by,the local jurisdiction's permit authority.A copy should be retained by the owner to demonstrate compliance in order to receive the best flood insurance rating. The Smart VENT®and Flood VENTfM Foundation Flood Vent is certified as meeting the flood opening requirements for engineered openings as set forth in the Federal Emergency Management Agency's National Flood Insurance Program regulations (44 CFR 60.3(c)(5»and ASCE 24- 98,provided it is installed according to the those references,as summarized below.Flood openings are required in enclosures below elevated buildings,attached and detached garages,and accessory structures that meet the required limitations.For a copy of the report documenting this certification dated June-21,2002,and a copy of the National Evaluation Service report NER 624,contact Smart VENT,Inc.,at 877/441-8368 or visit: www.smartvent.com I do hereby certify that the Smart VENT®Louvered Foundation Flood Vent and the FloodVENTTM Insulated Foundation Flood Vent opening (s)is designed for installation in buildings,will allow for the automatic equalizing of hydrostatic flood forces on exterior walls by allowing for the automatic entry and exit of floodwater during floods up to and including the base (IOO-year)flood.One Smart VENT® or one FloodVENTTM for every 200 Sq.Ft.of enclosed area will provide sufficient hydrostatic pressure equalization during a flood provided the installation limitations and instructions are followed as listed below.To Calculate the required number of Smart VENTS®or FloodVENTSTM divide the Square Feet of enclosed area by 200. Exam Ie:A 2000 S .Ft.enclosed area re Signature --"JL,-",==-__~-,---,!V=J...'_ Title S&.-.IIO;;nzroec.:r s=...•41..JIOER Type of License j(E6IS~IZ@ PeOFESSlo"'''L. License Number_.::::C>:.::S"o!....!!!~~/...J7:.!./-=-'-'£'=----_ *Project Name *Project Address _ *Date Submitted j,_ *Required Fields*Professional Seal Installation Limitations and Instructions I.The Smart VENT®or FloodVENTTM unit provides sufficient automatic equalization of hydrostaric pressure on walls and foundations of buildings located in flood hazard areas where the rate of rise is expected to be less than or approximately 5 feet per hour. 2.Enclosed areas below otherwise elevated buildings,non-elevated attached and detached garages,and certain non-elevated accessory structures located in flood hazard areas are to be used solely for parking of vehicles,building access,or storage. 3.Each enclosed area shall have at least two flood openings,installed on different sides of the enclosed area. 4.The bottom of the flood openings shall be no more than one foot above the adjacent finished ground level. 5.Installation must be in-accordance with manufacturer's instructions. "REFERENCE ONLY~From FEMA TB 1-93 Guidance for Engineered Openings enings in Foundation Walls ational Flood Insurance Pro ram NFIP Technical Bulletin TB 1-93 "In situations where it is not feasible or desirable to meet the openings criteria stated previously,a design professional (registered engineer or architect)may design and certify openings.This section provides guidance for such engineered designs.For openings not meeting all four requirements for non-engineered openings listed on page 2 and 3 of TB 1-93,certification by a registered professional engineer or architect is required.Such certification must be submitted to,and kept on file by,the community.These certifications must assure community officials that the openings are designed in accordance with accepted standards of practice.A certification may be affixed to the design drawings or submitted separately.It must include appropriate certification language,and the name,title,address,signature,type of license,license number,and professional seal of the certifier."(TB 1-93 is available through Smart VENT®or online at www.fema.gov) Form;SMRTIOO Rev.A This form is the property of Smart VENT Inc.Modification or Duplication is Strictly Prohibited without authorization. Certification of Engineered Opening (September 3,2002)8