Loading...
approval letter February 23, 2011 Wendy RobinsonFebruary 23, 2011 Wendy Robinson 81 Parsons Street Northampton, MA 01060 Subject Property: 81 Parsons Street Northampton, MA 01060 Ms. Robinson The plans for the your project dated 1-5-11 require additional information as noted; Bedrooms noted on plans. Clear line of unit separation noted on the plan. Smoke and CO detectors per code, including a separate system for each unit plus a heat detector within the unit connected to a smoke detector in the common stair hall. Structure conforms to 780 CMR 7th addition 1 and 2 family with 2009 IECC prescriptive (stretch code) requirements or RES Check 4.4.1 and mandatory requirements. Updated energy information and equipment must be posted on the electric panels upon completion. 5/8” drywall shall be installed over the entire 1st floor ceiling and all walls adjoining the common stair hallway. Doors entering the common stair hall need to be one hour rated doors. Clarification of separation and location of electric panels and other utilities. Deck framing details from footing/piers to the top of the structure. Accessory structure has a maximum allowable square footage of 900 square feet. A restrictive covenant must be executed and recorded, a copy of the receipt shall be provided to the building department before a final inspection can be completed. Charles Miller Assistant Commissioner of Buildings