08-021 (19) uw fIV A( ' System There are five package rooftop units with propane gas furnace for heating and direct expansion air conditioning for Looting. -Iwo 7.5-ton units will serve the second floor. Three in four-ton units will serve the first floor. Each unit on second floor will have two steps of coolmg capacity, two steps heating capacity. enthalpy controlled economizer with the capacity for 100% outside air. and efficient throwaway filters for cleaning the air. Each unit for first floor will be one stage heating and cooling, enthalpy controlled economizer with the capacity for 100% outside air, and efficient throwaway filters for cleaning the air. pag The air distribution systems will be low-pressure ducts to the tenant spaces. Each duct system will serve only one tenant space. Hie building will have individual thermostats though the building. 1 he controls will allow for tenant selected independent schedule for each day of. the week. All bathrooms and kitchen area be exhausted by duct system, and vented through roof. urn Lighting Application Worksheet Massachusetts Commercial Code COMcheck-EZ Software Version 2.2 Release la Section 1: Allowed Lighting Power Calculation F' A B C D Total Floor Allowed Allowed Area Watts Watts Building Type (ft2) (watts/ft2) (B x C) Office 11300 1.3 14690 Total Allowed Watts= 14690 Section 2: Actual Lighting Power Calculation A B C D E F Fixture Fixture Description/ Lamps/ #of Fixture ID Lamp Description Wattage Per Lamp/Ballast Fixture Fixtures Watt. (D x E) Type 1 8'Two Bulb Flourescent Strips/96"T12 Slim 75W/Electronic 2 4 118 472 Type 2 4'Two Bulb Flourescent Strips/48" T8 32W/Electronic 2 1 64 64 Type 3 2 x 4 Four Bulb Troffers/48"T8 32W/Electronic 4 51 128 6528 Type 4 2 x 4 Three Bulb Troffers/48" T8 32W/Electronic 3 25 96 2400 Type 5 2 x 4 Two Bulb Troffers/48"T8 32W/Electronic 2 17 64 1088 Type 6 2 x 2 Two bulb Troffers/24"T8U 32W/Electronic 2 5 64 320 Type 7 Round Recessed/Quad 2-pin 26W/Electronic 1 3 26 78 Type 8 Wall Sconce/Quad 2-pin 26W/Electronic 1 9 26 234 Total Actual Watts= 11184 Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero,the building complies. PP Total Allowed Watts= 14690 Total Actual Watts= 11184 Project Compliance= 3506 pia Lighting PASSES: Design 24%better than code PP Interior Lighting Total actual watts must be less than or equal to total allowed watts Allowed Watts Actual Watts Complies(Y/N) 14690 11184 YES Exterior Lighting Type(s)of exterior lighting sources: Fluorescent X_Metal Halide _High-Pr. Sodium Exceptions: Specialized signal,directional, and marker lighting; lighting highlighting exterior features of historic buildings; advertising signage; safety or security lighting;low-voltage landscape lighting. Section 4: Compliance Statement The proposed lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the Massachusetts Commercial Code requirements in COMcheck-EZ Version 2.2 Release la. TNT o'L iej Co Iti.0 F3 it-4 a N i4 i t,1. �.ti.tr A r 5/30/03 Principal Lighting Designer-Name Signature Date NM PO OM OM S AM .w Lighting Compliance Certificate Massachusetts Commercial Code COMcheck-EZ Software Version 2.2 Release la Section 1: Project Information con Project Information: Paradise Realty LLC 766 North King Street Northampton MA 01060 Owner/Agent Information: The O'Leary Co Inc. PO Box 377 Southampton MA 01073-0377 Document Author Information: Mike Byrnes Notes: Medical Office Building Section 2: General Information Building Location: Northampton,Massachusetts Climate Zone: 14a Heating Degree Days(base 65 degrees F): 6894 Cooling Degree Days(base 65 degrees F): 507 Building Use Method of Compliance: Whole Building Method r�. Building Type Floor Area Office 11300 Project Description(check one): -,New Construction _Addition Alteration _Unconditioned Shell(File Affidavit) Section 3: Requirements Checklist Inspection Approved Initial Date (Y/N) PP Controls,Switching,and Wiring Independent controls for each space(switch/occupancy sensor) Exceptions: Security lighting,building lobby/retail store/mall • Master switch at entry to hotel/motel guest room Two switches, dimmer,or occupancy sensor in each space providing a uniform illumination pattern Exceptions: Only one luminaire in space; An occupant-sensing device controls the area; The area is a corridor, storage, restroom, or lobby Photocell/astronomical time switch on ext. lights Exceptions: Large covered areas requiring lighting during daylight hours Tandem wired one-lamp and three-lamp ballasted luminaires Pi II Exceptions: Electronic high-frequency ballasted luminaires not on same switch PPM .. w .■ PPP OPP MIPS PPP ■. OP .w r Ow PO IMO IVO Ow Climate-Specific Requirements Gross Cavity Cont. Proposed Budget Component Name/Description Area R-Value R-Value U-Factor U-Factor Roof 1: Metal Roof with Thermal Blocks 5450 0.0 19.0 0.051 0.054 Exterior Wall 1:Metal Wall without Thermal Blocks 2016 0.0 13.0 0.072 0.079 Exterior Wall 2: Solid Concrete or Masonry<=8" Furring Metal 579 19.0 0.0 0.118 0.079 Exterior Wall 3: Metal Frame, 16" o.c. 3521 19.0 10.0 0.053 0.079 Exterior Wall 4:Metal Frame, 16" o.c. 965 19.0 15.0 0.042 0.079 Window 1: Metal Frame with Thermal Break,Double Pane with Low-E Tinted,shgc 0.52,pf 0.03 803 --- --- 0.436 0.547 Door 1: Solid 84 --- --- 0.700(b) 0.127 WA Door 2: Glass,Tinted, shgc 0.54,pf 1.00 21 --- --- 0.920(b) 0.547 Slab 1: Unheated On-Grade, Vertical Insulation Depth 4 ft.(o) 310 --- 8.1 --- --- U (a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. (b)Claimed performance does not exceed defaults in Tables 1301.9.3.1.No manufacturer certification required. (c)Certain building use types require continuous under-slab insulation(see Massachusetts Code Section 1304.2.7 and 1304.2.8). Envelope PASSES: Design 26%better than code orn Section 4: Compliance Statement The proposed envelope design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the Massachusetts Commercial Code requirements in COMcheck-EZ Version 2.2 Release la. ........Zeirt7a4.2 erFARLD R.c-p_s-opt .s--/rer74.r Principal Envelope Designer-Name Signature Date roll y G'a'`SS/ON4 E..0 PIM 5 MIR Envelope Compliance Report Massachusetts Commercial Code COMcheck-EZ Software Version 2.2 Release la MP Section 1: Project Information son Project Information: Paradise Realty LLC 766 North King Street Northampton MA 01060 Owner/Agent Information: The O'Leary Co Inc. PO Box 377 Southampton MA 01073-0377 Document Author Information: Mike Byrnes Notes: Medical Office Building Section 2: General Information tom Building Location: Northampton, Massachusetts Climate Zone: 14a Heating Degree Days(base 65 degrees F): 6894 Cooling Degree Days(base 65 degrees F): 507 Building Use Method of Compliance: Whole Building Method Building Type Floor Area Office 11300 Project Description(check one): New Construction _Addition _Alteration _Unconditioned Shell(File Affidavit) Section 3: Requirements Checklist Air Leakage,Component Certification,and Vapor Retarder Requirements Inspection Approved Initial Date (Y/N) All joints and penetrations are caulked, gasketed, weather-stripped, or otherwise sealed Windows, doors, and skylights certified as meeting leakage requirements PP Component R-values&U-factors labeled as certified Ps Vapor retarder installed OS OM -6- All tests will be performed by qualified personnel in the presence of representatives of the appropriate subcontractor, the general contractor, and the owner. PROJECT CLOSEOUT The owner will be provided one set of as-built drawings, one copy of all test results, and one set of systems operations and maintenance manuals. on MN PM ISO -5- UPI Electrical Power System See design intent section above. Lighting System See design intent section above. SEQUENCE OF OPERATION HVAC See attached HVAC narrative. Water Heating System mon See design intent section above. Lighting System See design intent section above on Compliance on Design Compliance with 780 CMR 13 is based on the results of the COM check compliance reports and a comparison of actual data with prescriptive criteria set forth in the applicable sections of Chapter 13. Envelope (see attached COM check compliance report) Passes Interior Lighting (see attached COM check compliance report) Passes Construction and installation compliance will be based on field inspections by the appropriate contractor and designer of record. w Operational compliance will be based on field testing and inspections by the appropriate contractor and designer of record. See attached HVAC narrative for testing schedule. Water heating system test will include the hot water re-circulation time clock operation only. Lighting system tests will include fixture lamp and photoelectric and motion sensing control operations. -4- Outdoor Ambient Design Temperatures Winter--minus 1°F Summer--86°F (dry bulb) and 73°F (wet bulb) Heating Degree Days--Base 65 6,894 Cooling Degree Days--Base 65 507 Interior Temperature Setpoints Heating unoccupied--see attached HVAC narrative Heating occupied-- see attached HVAC narrative Cooling unoccupied-- see attached HVAC narrative - Cooling occupied-- see attached HVAC narrative Miscellaneous HVAC Requirements Humidity-- see attached HVAC narrative Ventilation air-- see attached HVAC narrative Filtration-- see attached HVAC narrative Background noise-- see attached HVAC narrative Electrical Loads (see attached COM check compliance report) Interior lighting power allowance--office use--11,300 square feet at 1.3 watts per gross square foot Total allowable interior lighting load--14,690 watts Total actual interior lighting load--11,184 watts ■,,, Miscellaneous receptacles--overall average--11,300 square feet at 0.75 watts per gross square foot Exterior parking and sidewalk areas--19,000 square feet Total actual exterior lighting load--2,950 watts U' SYSTEM CAPACITIES HVAC See attached HVAC narrative. U' Water Heating System See design intent section above. U sin eye —3— Split switching of lamps in drop-in lights in perimeter offices with windows will be utilized,thus allowing for one-third, two-thirds, or full design lighting levels to be achieved. - Dimming controls will be utilized on accent lights. Each of the remaining rooms will be controlled by a single manual switch. Exterior lighting will utilize photoelectric controls. PIM Emergency lights will be automatically off during normal business hours and will be battery powered. Compliance The designer of record will certify that each system has been constructed or installed in accordance with the approved construction documents. IN BASIS FOR DESIGN The following information has been used to design HVAC and electrical systems and to determine compliance with 780 CMR 1301: Envelope (see attached COM check compliance report) Roof: 5,450 square feet with U=0.051 Opaque walls with metal panels: 2,016 square feet with U= 0.072 with masonry: 579 square feet with U=0.118 with EIFS: 3,521 square feet with U= 0.053 965 square feet with U=0.042 Hollow metal doors: four at 3' x 7'= 84 square feet with U=0.700 Aluminum/glass doors: one at 3' x 7' =21 square feet with U=0.920 Windows: 803 square feet with SHGC = 0.52 U=0.34 SC =0.45 Occupancy Normal operation: 60 Climate Zone Hampshire County--Zone 14a LPN s�. -2- HVAC System See attached narrative. Water Heating System N Hot water for each tenant space will be produced by individual electric heaters with integral heat traps. All hot water supply and return piping will be insulated with 3/4" thick Armaflex. Electrical Power System a An 800 amp, 120/208 volt, 3 phase, 4 wire electric service with metering and distribution panels for each of four tenants will be provided. a In addition to convenience power receptacles and HVAC equipment, the building electrical distribution system will provide power to water heaters, elevator, appliances, and miscellaneous office equipment. Lighting System Lighting will be designed to maintain the following foot candle levels: Site lighting 1 fc Offices, exam, and conference rooms 70 fc Remaining areas 30 fc Parking area lighting will consist of wall and pole mounted fixtures with 175 and 250 watt metal halide lamps. Direct mount strip lighting fixtures will be utilized in the future tenant area. Wall sconces will be installed in stairwells. A combination of 2' x 2' and 2' x 4' recessed drop-in light fixtures with acrylic prismatic lenses or parabolic louvers will be used throughout and remaining areas. two Round recessed down light fixtures will be installed as accent lighting in the second floor conference room. Energy efficient T8 or compact fluorescent lamps with electronic ballasts will be utilized throughout except as noted above. Motion sensing controls will be utilized in the utility and storage rooms and bathrooms. ■ s MASSACHUSETTS STATE BUILDING CODE 780 CMR 13 COMPLIANCE NARRATIVE FOR PARADISE REALTY PARTNERS,LLC 766 NORTH KING STREET NORTHAMPTON, MASSACHUSETTS MAY 30, 2003 DESIGN INTENT PIP General The project will be a two-story multi-tenant professional building (Use Group B)with 5,650 square feet on each floor for a total useable floor area of approximately 11,300 square feet. It is anticipated that the building will be normally occupied five days a week between the hours of 7 a.m. and6p.m. The facility will house a normal everyday occupancy of approximately 60 employees and visitors. The site layout will include approximately 19,000 square feet of paved sidewalk and parking area. Building Description The building will consist of preengineered steel framing with concrete slabs on grade and deck. A standing seam metal roof with 6" of glass fiber preengineered building (PEB) insulation(laid over the purlins)will be used throughout. A 1" rigid foam spacer block will be installed between the roof and purlins. A polypropylene/scrim/kraft vapor barrier will be installed at the warm side of all roof insulation. No skylights will be utilized. Walls at the west side of the building will be metal panels with 4" of PEB insulation and PSK vapor barrier. Remaining walls will be constructed using 6" steel studs with interior and exterior gypsum board sheathing. Stud cavities will be insulated with 6" glass fiber batts. A 4 mil flame retardant polyethylene vapor barrier will be installed at the warm side of all stud walls. Exterior finish at the stud walls will consist of masonry veneer to 3'0" and EIFS with 2" and 3" thick rigid foam insulation above. or Exterior windows will be inoperable and will consist of thermally broken aluminum frames and 1" double pane bronze tinted low e glass. Interior blinds will be utilized. Walk-in doors will be glass and aluminum or hollow metal with full weatherstripping. IMP This Side For Use by Building Department Only NIP Official's Name: Title: I. Plans Review Date Application Received: ❑ Nip Complete Narrative Report Received(1301.8.4.1) ❑ Design and Specification Documents prepared by legally recognized professional (1301.8.4.3) Application is: Approved ❑ Date: Signature: Denied ❑ Date: Reason(s)for Denial: (provide additional details as needed on separate sheet) MI'" NIR PIM MP II. Acceptance (1301.8.4.4) ❑ Successful system tests witnessed by Building Official, OR ❑ satisfactory test report received(check one) ❑ Certification by Registered Professional(per 780 CMR 116.2)that systems are installed in accordance with construction documents ❑ Confirmation by owner(or their authorized representative)that they have received record drawings, .� reviewed for reasonable accuracy ❑ Confirmation by owner(or their authorized representative)that they have received reports, controls documentation, operations manual(s), maintenance manual(s), and other documents specified in 1301.8.4.1 •• Building Official's Signature: ww ENERGY CONSERVATION MANDATORY CHECKLIST FOR NEW CONSTRUCTION (OTHER THAN LOW-RISE RESIDENTIAL) 780 CMR, 1301.8.1 Owner/Agent Name: Paradise Realty Partners, LLC Phone: 413-785-1153 Owner/Agent Address: 1275 Elm Street City/State/Zip: West Springfield. MA 01089 Project Name: Paradise Realty Partners, LLC Site Address: 766 North King Street City/Town Northampton, MA Brian Hill for , � Applicant's Name: The O'Leary Company, Inc. Signature: ,/_ r J.L Applicant's Phone: 413-527-1360 Date of Application: 5/30/03 I. Envelope Compliance Option (check ONE) p © Trade-Off (1304.5)-Attach software Compliance Report(COMcheck-EZ) ❑ Appendix J(1301.2-For buildings up to 10,000 sf only)-Attach Appendix J compliance documentation ❑ Systems Analysis(1309)-Attach Registered Architect's or Engineer's report ❑ Prescriptive(1304.2)-Complete this section, and attach copy of applicable Table(1304.2.1 through 13.4.2.12) Climate Zone(from Table 1303.1) ❑ Zone 12a ❑ Zone 13a © Zone 14a a. Gross above-grade wall area 7,989 sq.ft. b. Total window& glass door area 824 sq.ft. c. Glazing%(100 x b=a) 3. 14 % Table# utilized: 1304.2.9 II. HVAC (check ONE) ❑ Simple Systems& Equipment(1305.2) I Complex Systems&Equipment(1305.3) ❑ Systems Analysis(1309)-Attach Registered Architect's or Engineer's report III. Lighting(check ONE) © Building Area Method(1308.6.2.1) I Attach Compliance Documentation(COMcheck-EZ or other) I ' ❑ Space-by-Space Method(1308.6.2.2) ❑ Systems Analysis(1309)-Attach Registered Architect's or Engineer's report IV. Approval & Acceptance Construction Documents (1301.8.4.1) Attach a narrative report describing the HVAC, Lighting,and Electric Distribution systems, including: For Official Use ONLY: ❑ 1. Design Intent ❑ 2. Basis of Design Building Official check off ❑ 3. Sequence of operation/systems interaction completed ❑ 4. Description of the systems(capacities, etc.) sections of report ❑ 5. Testing requirements/criteria acceptance ❑ 6. Requirement for submittal of operation manuals and maintenance manuals ❑ 7. Requirement for submittal of record drawings and control documents lom TABLE OF CONTENTS Section A-- Energy Conservation Mandatory Checklist for New Construction Section B -- Compliance Narrative Section C -- Envelope COM Check Compliance Report Section D -- Lighting COM Check Compliance Certificate Section E -- Supplemental HVAC Compliance Narrative MIN ale PIN in OR ell MASSACHUSETTS STATE BUILDING CODE 780 CMR 13 COMPLIANCE REPORT FOR PARADISE REALTY PARTNERS,LLC 766 NORTH KING STREET NORTHAMPTON,MASSACHUSETTS MAY 30, 2003 IN OPP PP PO PP PM