25C-091 (5) 39. If there is mechanical equipment or a combustible roof, 30 sqft of space, and 30" measured from top of ceiling joist to bottom of rafters an attic access of minimum RO of 22" x 30" is required to be located in an accessible place. It must be insulated,gasketed, and secured in place. Relevant items must be submitted to the building department for approvals before inspections and or Certificates of Occupancy can be issued. Feel free to call if you have any questions. My telephone number is 587-1240 and office hours are Monday through Friday,8:30 am to 4:30 pm,excepting we close for walk-ins at 12:00 noon on Wednesdays. My email address is: cmiller @northamptonma.gov Thank you for your cooperation on these matters. uck i e City of Northampton Assistant Commissioner and Zoning Enforcement 24. Drilling or notching of more than 50%of the wall plate width of an exterior wall or load bearing partition requires a 16 GA 1 1/2" strap across the area and 6" beyond each side with 8-10nd nails. 780 CMR R602.6.1 25. Dryer ducts must terminate outside of the building, have a backdraft damper,cannot include a screen, and require 3'clearance from windows.780 CMR M1502.3 26. Dryer duct transition is limited to 8' of aluminum flex, must be exposed, and the proper UL listing.780 CMR M1502.4.3 27. Dryer duct maximum equivalent length is 25' less 5' per 90°elbow or per manufacturer's specs. 780 CMR M1502.4.4.1, no screwed connections. 28. Markup air is required for any exhaust hood of 400 CFM or more.780 CMR M1503.4 29. Fireplaces require all combustion air be provided from the exterior and below the firebox, duct work maintaining 1" clearance for 5'from the duct outlet for all fireplaces and airtight doors. 2009 IECC 402.4.3 30. Fire and draft stopping shall be completed before rough inspection.Typical locations,top (ceiling)and bottom (floor) plates, soffits, and every 10'within enclosed cavities. 780 CMR R302. 31. Ignition barriers are required over all thermal plastics and must be in place before final. 780 CMR R316. 32. Dwelling/Garage fire separation.An attached garage (within 3' of main structure) is required to have%" drywall on the garage side of the separation wall and if there is a finished space above the garage all walls must have 1/2" drywall and the ceiling 5/8" drywall. 780 CMR R302.6 33. Energy aspects shall comply with the stretch energy code.780 CMR Appendix 115AA or 2009 IECC. a. An initial HERS evaluation is required including insulation levels anticipated. b. A final HERS evaluation confirming code requirements have been met including duct testing. c. A signed copy of the Thermal Bypass Checklist. d. Energy information including mechanical equipment posted on the electric panel. e. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy Star Windows and the Thermal Bypass Checklist. Duct blast testing when practicable. f. All band joist insulation must be enclosed within an air tight cavity,which you must create. 34. Vapor retarders.Although these are still in the code have exceptions, one must understand that there is a difference between a vapor retarder or barrier and an air barrier.An air barrier is intended to stop air flow(convection) a vapor retarder or barrier is intended to stop molecular moisture transfer(diffusion). A vapor retarder or barrier is effective even if there are some holes or gaps, however an air barrier has to be absolute and complete. If air can leak through an electrical device or through a crack it follows the path of least resistance and carries 99%of the moisture in a structure.This is evident every time one exposes fiberglass insulation and finds black insulation, which is dirt filter out of the air moving through the insulation. 780 CMR R601.2 for vapor retarders and Table N1102.4.2 for air sealing requirements. 35. Unvented attic assemblies. Hot roofs are allowed, but have specific requirements 780 CMR R806.4. 36. Deck ledgers and post must be appropriately attached, bolts or lags.780 CMR R502.2.2.1 Note:ThruLoks are engineered for post attachment supporting a railing. Lateral attachment is required for each deck per section 502.2.2.3. 37. Smoke and CO detectors as required.780 CMR R314 and R315. a. Smokes in each bedroom,within 10' of a bedroom door,and at the bottom of a stair leading to a finished floor above. b. CO within 10'of bedroom doors,at each level,for every 1500 sqft, (plumbing code in the mechanical room) Except if there are no fossil burning fuels. c. Heat detector in attached garage, and other large unfinished unconditioned spaces. 38. Closets beneath stair which have doors must be drywalled with 1/2".780 CMR R302.7 11. Steel straps over the ridge or 1x4 minimum collar ties are required 4' OC in the upper 1/3rd780 CMR R802.3.1 12. Ridge boards must be the full depth of the cut. 780 CMR R802.3. 13. A complete window and header schedule is required.780 CMR Table R502.5 for header sizing and number of jack studs required. 14. All framing materials which are not code prescriptive must have stamped engineering. a. LVLs b. I-joist and or Floor Truss c. Roof truss 15. A braced wall plan identifying appropriate braced wall areas where required (R301.1) and braced wall method being used. 780 CMR 602.10. a. Garage corners and large corner window/door layout may require special solutions. b. All corners must be appropriately attached to the foundation. c. When using PFH (R602.10.3.3) or PFG (R602.10.3.4)the nailing requirement is 4" and 3" respectively using 8d common nails or galvanized box nails. PNEUMATIC nails must be full headed with the temper and shank sizing meeting the strict code requirement. 16. When nailing sheathing make sure your pneumatic nailers' pressure is properly set. Nails set too deep perforate the sheathing weakening it and contribute to building damage in high wind events. 17. Ceiling heights minimum 7'for habitable spaces, 6'8"for bathrooms includes tub/shower area if a shower head is used, 6'8" for basements, 6'4" at beams/ducts. 780 CMR R305.1. MA amended 18. Hazardous glazing locations, within 24" of a door,or within 60" of a stair, or across from hot tubs,spas, bathtubs within 60" if not 60" above the walking surface, and other locations.780 CMR R308.4 19. Windows over 72" above grade with the opening less than 24 above the finished floor shall meet the 4" sphere rule.Order restrictors. 780 CMR R612.2 20. Egress and emergency escape requirements shall be strictly met. a. Basements, habitable attics, and all sleeping rooms require emergency escape.780 CMR R310 b. Windows within 44" of floor, DH 3.3 sqft min window size, Casement 20"x41" exception 5 sqft at 1st floor. Minimum clear opening 20"x24" or 24"x20". 780 CMR R310.1.1 c. Two doors remote as possible at the normal level of travel, opening measured from the face of the slab to the stop with door at 90 degrees,one 32" and one 28" minimum 78" high.780 CMR R311.2 d. Landing at each door 36" out and the width of the door minimum 36", maximum step 7 3/" from the top of the threshold and only in-swinging doors.780 CMR R311.3 21. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9", maximum riser 8%", maximum overall variance for the run is 3/8",4" sphere rule on risers except where the total rise is 30" or less 780 CMR R311.7.4.3 Exception,4 3/8"on balustrade, 6" in the triangle. Graspable rail 1''4" minimum and 2" maximum rail, height minimum 34" maximum 38", required for 4 or more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling height from nosing. Rails must be continuous and returned to the wall if not to newel post.780 CMR R311.7. 22. Guards 36" minimum height above walking surface, a bench is a walking surface, required for more than 30" above floor or grade within 36",4" sphere rule.780 CMR R312.1. 23. Educate the plumber and electrician about maximum notch and hole sizes, and placement.780 CMR R502.8 and R602.6. In bearing studs holes not larger than 40%of a stud no closer than 5/8 to the edge, In interior non-bearing studs holes not larger than 60%of a stud no closer than 5/8 to the edge, or holes in joist are a maximum 1/3 the depth not closer than 2"from the top or bottom or to any other hole. Notches are different. City of Northampton Massachusetts v DEPARTMENT OF BUILDING INSPECTIONS o 212 Main Street • Municipal Building b �. Northampton, MA 01060 INSPECTOR Matt Murphy November 18, 2013 329 Southampton Road Westhampton, MA 01027 Subject Location:44 Lincoln Avenue Map Block: 25C-091 Mr. Murphy, Your building permit application and plans dated 7-17-13 have been approved as drawn, noted and per this memo.All changes to the permit plans must be documented.All work must meet all applicable codes whether noted or not included within this memo. Please follow up on the following items: These items will need to be accomplished as the project moves forward and before rough inspections; 1. The floor beam shown for the screen porch in Line 1, Rows E to F appears to be undersized. 2 2x8 12 span with 4' of floor load. 2. The fireplace requires makeup air and sealed glass doors. 3. A smoke and CO detector is required within 10' of the first floor bedroom door. Note August 16th 2013 begins the newest energy code 2012 IECC with MA amendments with a concurrency period until July 1,2014 and an expectation that a new Stretch Code will be forth coming. As of August 4th 2011 the 8th Edition MA code is the 2009 IRC with MA amendments. In the following are some generic requirements which seem to be problematic. This is not intended to be comprehensive, nor is it a substitute for purchasing and reading the MA codes. Read only international codes are available on line at http://publicecodes.cvberregs.com/icod/one must also consider the MA amendments to these codes which can be found at www.mass.gov/dps/bbrs The current relevant building codes are: 2009 IBC, 2009 IEBC,2009 IMC, 2009 IRC, 2009 or 2012 IECC,AA115, MA amendments. 1. Structures shall conform to 780 CMR 8th Edition 1 and 2 family building codes with MA amendments. 2. Grading plan for structures being constructed required.780 CMR R401.3 for drainage requirements. 3. A basement drainage system is required in all basements 780 CMR R405.2.3. except those in group I soils(table R405.1) 4. Foundations that retain earth and enclose interior space require damp proofing 780 CMR R406.1. 5. Through wall form ties must be removed from both faces and patched with hydraulic cement.780 CMR R406.2 of amendments. 6. Foundation anchor bolts must be%" and be embedded a minimum of 7" into the concrete. 10" bolts! 780 CMR R403.1.6 7. CMU foundations require 3/8" parging before damp proofing.780 CMR R406.1 see exceptions. 8. Emergency escape is required out of every basement whether habitable or not.780 CMR R310.1 9. Crawl spaces can be treated in three different ways,vented (poor idea), exhausted (similar to exhaust only systems),or treating the space with supply and return.See 780 CMR R408 10. Ceiling joist are intended to prevent spread,once raised above the wall plate they become rafters ties and may require up sizing of rafters and increased nailing for example with a 4" slope 8-16nd common are required at each connection. 780 CMR R802.3.1. When there is neither of these a structural ridge is required with a load path to the foundation. OQL.._,A t..p CITY OF NORTHAMPTON, MASSACHUSETTS �" DEPARTMENT OF PUBLIC WORKS brim) . 125 Locust Street X30: _, Northampton, MA 01060 b�. 413-587-1570 Fax 413-587-1576 Edward S. Huntley, P.E. Director r r`,�~---<. , , l, , ,;�-- _ Q 2u03 November 14, 2013 , Mr. Louis Hasbrouck, Building Commissioner °' 212 Main Street, Room 100 Northampton, MA 01060 Dear Mr. Hasbrouck, Mr. Matt Murphy of 44 Lincoln Avenue,Northampton, MA., asked me to inspect his capped sewer service. This morning on November, 14, 2013, at 8:00 a.m., we televised the house service at 44 Lincoln Avenue. There is a piece of black P.V.C. pipe with a screw-on cap. The pipe goes into what was the dirt floor and attaches to the cast iron pipe leaving the house which then switches back to clay pipe. It is in good condition. Mr. Murphy was present for the inspection. Si erwely�, iva_el GJ�`� n Hall Sewer Department Foreman Cc: Matt Murphy file ti =,r=_; Citla. of Northampton 1.%1----------------r $a:J �:, )� _ AA assarlfnstffst= _ ,4 '—'1 DEPARTMENT OF BUILDING INSPECTIONS -— INSPECTOR 212 Main Street 0 Municipal Building 7'a.,� Northampton,MA 01060 WIN LOCATION 1/1"/ Li it/Co/'/ ,q v T SQUARE FOOTAGE AMOUNT BASEMENT @ .20 /07;2 .,9/V. Yo 1ST FLOOR @.50 AO 7? 5-86 2ND FLR @.30 936 .2 80, a''® %Z FLOORS, FINISH ATTIC,GARAGE @.20 5.76 //� ., o2 0 DECK/PORCHES @ .20 d247 yam' /.0 TOTAL. /13 . FO ergy Eite i insulation Ratings Ceiling/Roof 44.00 Wall 35.00 Floor/Foundation 15.00 Ductwork(unconditioned spaces): Glass&boor Rating U-Factor SHGC Window 0.29 0.28 Door 0.23 0.26 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Building Air Leakage and Duct Test Results Building Air Leakage Test Results Name of Air Leakage Tester Duct Tightness Test Results Name of Duct Tester Name: Date: Comments: Project Title: Spink-Nguyen Residence Report date: 07/18/13 Data filename: C:\Users\rheannon\Documents\REScheck\Spink-Nguyen.rck Page 5 of 5 (a)piping serves more than one dwelling unit, (b)piping between water heater and kitchen or water heater and distribution manifold, (c)piping outside conditioned space,buried,or located under a floor slab, (d)supply and return piping in recirculation systems other than demand recirculation systems, (e)piping is>3/4 inch nominal diameter, (f) piping runs>30 feet having 3/8 inch max diameter, (g)piping runs>20 feet having 1/2 inch max diameter, (h)piping runs>10 feet having 3/4 inch max diameter, (i) piping runs>5 feet having max diameter within the run>3/4 inch. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to R-3. ❑ HVAC piping insulation exposed to outdoor elements is protected from damage and shielded from solar radiation. Ventilation: • Ventilation fans satisfy the following efficacy criteria: (1)Range hoods and in-line fan:2.8 cfm/watt. (2)Bath-/utility room with rated cfm>=10>and<90: 1.4 cfm/watt. (3)Bath-/utility room with rated minimum cfm>=90:2.8 cfm/watt. Swimming Pools and In-ground Spas: ❑ Heaters have an readily accessible on-off switch. o Heaters operating on natural gas or LPG have an electronic pilot light. D Schedule-capable automatic on-off timer switches are installed on heaters and pumps. Exceptions: Where public health standards require continuous pump operation. Where pumps operate within solar-and/or waste-heat-recovery systems. Heated pools and spas have a vapor retardant cover. Exceptions: Covers are not required when 70%of the heating energy is from site-recovered energy or solar energy source. Lighting Requirements: ❑ Within permanently installed fixtures,75 percent contain only lamps that can be categorized as one of the following.Or,a minimum of 75 percent of all lamps within permanent fixtures can be categorized as one of the following: (a)Compact fluorescent (b)T-8 or smaller diameter linear fluorescent (c)40 lumens per watt for lamp wattage<=15 (d)50 lumens per watt for lamp wattage>15 and<=40 (e)60 lumens per watt for lamp wattage>40 Exceptions: Low voltage lighting systems. ❑ Fuel gas lighting systems have electronic pilot lights. Other Requirements: ❑ Snow-and ice-melting systems with energy supplied from the service to a building shall include automatic controls capable of shutting off the system when a)the pavement temperature is above 50 degrees F,b)no precipitation is falling,and c)the outdoor temperature is above 40 degrees F(a manual shutoff control is also permitted to satisfy requirement'c'). Certificate: ❑ A permanent certificate is provided on or in the electrical distribution panel listing the predominant insulation R-values;window U-factors;type and efficiency of space-conditioning and water heating equipment;and results from any required duct system and building envelope air leakage testing.The certificate#does not cover or obstruct the visibility of the circuit directory label,service disconnect label or other required labels. NOTES TO FIELD:(Building Department Use Only) Project Title: Spink-Nguyen Residence Report date: 07/18/13 Data filename: C:\Users\rheannon\Documents\REScheck\Spink-Nguyen.rck Page 4 of 5 o Insulation in floors(including above garage and cantilevered floors)is installed to maintain permanent contact with underside of subfloor decking.Exterior insulation for framed walls is in substantial contact and continuous alignment with the air barrier.Crawl space wall insulation installed in lieu of floor insulation is permanently attached to crawlspace walls. Inspection of log walls is in accordance with the provisions of ICC-400. o Spaces between fenestration jambs and framing and skylights and framing are sealed.Batts in narrow cavities are cut to fit;or narrow cavities are filled with insulation that readily fills the available cavity space. p Exposed earth in unvented crawl spaces is covered with Class I vapor retarder with overlapping joints taped. o Air sealing is installed between the garage and conditioned spaces. D Exterior walls adjacent to showers and tubs are insulated and have air barrier separating the wall from the shower and tubs. o Access openings,drop down stairs or knee wall doors to unconditioned attic spaces are insulated and sealed. p Recessed light fixtures installed in the building thermal envelope are IC rated,airtight labeled at air leakage rate<=2.0 cfm,and sealed to the drywall with gasket or caulk. • Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space are air sealed. j Plumbing and Wiring:Insulation is placed between the exterior of the wall assembly and pipes.Batt insulation is cut and fitted around wiring and plumbing,or for insulation that on installation readily conforms to available space such insulation shall fill all space between wall and piping/wiring. o Air barrier extends behind electrical or communication boxes or,air sealed type boxes are installed. D HVAC register boots that penetrate building thermal envelope are sealed to subfloor or drywall. Li Fireplace walls have air barrier and closure doors are gasketed. Sunrooms: D Sunrooms that are NOT thermally isolated from the building envelope meet the requirements applicable to the building envelope. Materials Identification and Installation: D Materials and equipment are installed in accordance with the manufacturer's installation instructions. • Materials and equipment are identified so that compliance can be determined. Li Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. o Insulation R-values and glazing U-factors are clearly marked on the building plans or specifications. Duct Insulation: j Supply ducts in attics are insulated to a minimum of R-8.All other ducts in unconditioned spaces or outside the building envelope are insulated to at least R-6. Duct Construction and Testing: Li Building framing cavities are not used as ducts or plenums. o All joints and seams of air ducts,air handlers,and filter boxes are substantially airtight by means of tapes,mastics,liquid sealants, gasketing or other approved closure systems.Tapes,mastics,and fasteners are rated UL 181A or UL 181B and are labeled according to the duct construction.Metal duct connections with equipment and/or fittings are mechanically fastened.Crimp joints for round metal ducts have a contact lap of at least 1 1/2 inches and are fastened with a minimum of three equally spaced sheet-metal screws. Exceptions: Joint and seams covered with air-impermeable spray foam. Where a partially inaccessible duct connection exists,mechanical fasteners can be equally spaced on the exposed portion of the joint so as to prevent a hinge effect. Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). o All ducts and air handlers are located within conditioned space. Temperature Controls: • Where the primary heating system is a forced air-furnace,at least one programmable thermostat is installed to control the primary heating system and has set-points initialized at 70 degree F for the heating cycle and 78 degree F for the cooling cycle. o Heat pumps having supplementary electric-resistance heat have controls that prevent supplemental heat operation when the compressor can meet the heating load. Heating and Cooling Equipment Sizing: o Equipment is sized in accordance with ACCA Manual S based on building loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies. ❑ For systems serving multiple dwelling units documentation has been submitted demonstrating compliance with 2012 IECC Commercial Building Mechanical and/or Service Water Heating(Sections C403 and C404). Circulating Service Hot Water Systems: Li Systems include an automatic or accessible manual switch to turn off the circulating pump when the system is not in use. u Pipes are insulated to R-3 when any one of the following apply: Project Title: Spink-Nguyen Residence Report date: 07/18/13 Data filename:C:\Users\rheannon\Documents\REScheck\Spink-Nguyen.rck Page 3 of 5 REScheck Software Version 4.4.4 Inspection Checklist Energy Code: 2012 IECC Location: Northampton, Massachusetts Construction Type: Single Family Project Type: New construction Building Orientation: Bldg.faces 180 deg.from North Glazing Area Percentage: 14% Heating Degree Days: 6404 Climate Zone: 5 Ceilings: ❑ Ceiling 1:Cathedral Ceiling,R-44.0 cavity insulation Comments: Above-Grade Walls: ❑ Wall 1:Wood Frame,24"o.c.,R-35.0 cavity insulation Comments: Basement Walls: ❑ Basement Wall 1:Solid Concrete or Masonry,7.3'ht/5.5'bg/7.3'insul,R-15.0 continuous insulation Comments: Windows: ❑ Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.289 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1:Solid,U-factor:0.330 Comments: This door is exempt from the U-factor requirement. ❑ Door 2:Glass,U-factor:0.300 Comments: ❑ Door 3:Solid,U-factor:0.230 Comments: Floors: ❑ Floor 1:Slab-On-Grade:Unheated,5.5'insulation depth,R-15.0 continuous insulation Comments: Slab insulation extends down from the top of the slab to at least 5.5 ft.OR down to at least the bottom of the slab then horizontally for a total distance of 5.5 ft. Air Leakage: ❑ Building envelope air tightness complies by a post rough-in blower door test result of less than 3 ACH at 50 pascals. ❑ Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. ❑ Wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. Air Barrier,Sealing,and Insulation Installation Criteria: •.' Ci A continuous air barrier is installed in the building envelope including rim joists and exposed edges of insulation.Breaks or joints in the air barrier are sealed.Air permeable insulation is not used as a sealing material. ❑ Junction of foundation and wall sill plates,wall top plate and top of wall,sill plate and rim-band,and rim band and subfloor are sealed. Corners,headers,and rim joists making up the thermal envelope are insulated. Project Title: Spink-Nguyen Residence Report date: 07/18/13 Data filename: C:\Users\rheannon\Documents\REScheck\Spink-Nguyen.rck Page 2 of 5 1 4CREScheck Software Version 4.4.4 .. 1 Compliance Certificate Project Title: Spink-Nguyen Residence Energy Code: 2012 IECC Location: Northampton, Massachusetts Construction Type: Single Family Project Type: New construction Building Orientation: Bldg.faces 180 deg.from North Glazing Area Percentage: 14% Heating Degree Days: 6404 Climate Zone: 5 Construction Site: Owner/Agent: Designer/Contractor: 44 Lincoln Ave Michael and Thuy Spink-Nguyen Rheannon DeMond Northampton,MA 01060 44 Lincoln Avenue Benson Woodworking Company, Inc. Northampton,MA 01060 6 Blackjack Crossing Road Walpole,NH 03608 603-756-3600 rheannon @bensonwood.com "t8��.. � � ijkiitte-off � ��'� � y��i it ii..,,h;� � ��. <n %e„ �, d��„, .�,,,,o ., Compliance:12.8%Better Than Code Maximum UA:453 Your UA:395 The%Better or Worse Than Code index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Gross Cavity Cont. Glazing UA Assembly Area or R-Value R-Value or Door Perimeter U-Factor Ceiling 1:Cathedral Ceiling 1398 44.0 0.0 34 Wall 1:Wood Frame,24"o.c. 2201 35.0 0.0 78 Orientation:Unspecified Window 1:Wood Frame:Double Pane with Low-E 272 0.289 79 SHGC:0.28 Orientation:Unspecified Door 1:Solid 26 0.330 9 Orientation:Unspecified Door 2:Glass 41 0.300 12 SHGC:0.26 Orientation:Unspecified Door 3:Solid 44 0.230 10 Orientation:Unspecified Basement Wall 1:Solid Concrete or Masonry 1362 0.0 15.0 68 Orientation:Unspecified Wall height:7.3' Depth below grade:5.5' Insulation depth:7.3' Floor 1:Slab-On-Grade:Unheated 160 15.0 105 Insulation depth:5.5' Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2012 IECC requirements in REScheck Version 4.4.4 and to comply with the mandatory requirements listed e -' S he, Inspection Checklist. tea, n .�-� Name-Title Signa •re j '„�roY , Da e /�`�,;Gp. S .4e, C), PL'i.20.981 Project Title: Spink-Nguyen Residence \ -ff��• Report date: 07/18/13 Data filename: C:\Users\rheannon\Documents\REScheck\Spink-Nguyen.rck Page 1 of 5 MUNICIPAL WATER AVAILABILITY APPLICATION Northampton Water Department 237 Prospect St. Northampton,MA 01060 587-1097 A Department of Public Works Trench Permit shall be required prior to any construction or connection activity associated with this application. Location: 44 Lincoln Avenue Inquiry Made By: Matt Murphy 237-4415 Demo/rebuild Date of Inquiry: 11/04/13 Number of Type of Single Family X Type of Private X Units: 1 Unit(s): Apart. Comm Ownership: Condo Multi-family Rental (Applicant to fill out the above) Municipal Water Main in Existing service to Front of Location? Yes: X No: site? Yes: X No Size of Water Main: 6" Material: Cast Iron Age: 1934 Approximate Static Street Flow Test Conducted: Yes: No: X Pressure: 110psi If done attach results Size of Service Connection 3/4" Existing Suggested Meter Size: 5/8 Comments: The Water Department cannot guarantee adequate water pressure during peak demand times at elevations above 320 feet. Contractor to utilize existing service. • A corresponding water entrance fee shall be paid prior to making any connection to the municipal water system. • Arrangements of such installation shall be made with the Northampton Water Department with a minimum of ing days notificati•- •,_: All work hall con . Nirthampton Water Department specifications. David W. Sparks, Superintendent of Water Dept. Water Entry$N/A Meter$N/A Radio $N/A cc: Ned Huntley,Director cc: Louis Hasbrouck,Building Commissioner Note: If this availability is for a new construction,it must be hand delivered to the Building Inspector. ,srnb I.admin`,.Pennits`'Vater Application Water Availabilit�.doe MUNICIPAL SEWER/AVAILABILITY APPLICATION Northampton Streets Department 125 Locust Street Northampton, MA 01060 587-1570 A Department of Public Works Trench Permit and Sewer Entry Permit shall be required prior to any construction or connection activity associated with this application. Location: 44 Lincoln Avenue Inquiry Made By: ,r Tom Fenton , Duffy Willard Paving 586-1477 C rac4or � ',t '^ Z-37-'1415 Date of Inquiry: "�^�`f' 11/04/13 Reason for Request: Demolition of Old Home and Rebuilding would like to hook into sewer Municipal Sewer Main in Front of Location: Yes >c No Municipal Storm Drain Available: 5'/2 deep Yes x No Size of Sewer Main: R ' Material: CZ-AY Age: L 8 ?ok Depth of Sewer Main: 6 rz- Length of Sewer Main: q is Size of Service Connection: V 111 K A/ CcJ /./ Type of Service Connection: Tie-in to Sanitary Main Tie-in to Sanitary Stub Comments: Note: If this availibilitv is for new construction,this form must be hand delivered to Building Inspector. A corresponding"sewer entrance fee"shall be paid prior to making any connection to the municipal sewer system.Arrangements of such installation shall be made with the Northampton Streets Department with a minimum of 5 working days notification. All work shall conform to Northampton Streets Department specifications. CI /Zit John Hall Sewer Department cc: Ned Huntley, Director DPW Louis Hasbrouck, Building Commissioner Home Energy Rating Certificate 44 Lincoln Ave Northampton,MA 01060 Estimated Annual Energy Cost , A A A 5 Stars Plus Use MMBtu Cost Percent Projected Rating Heating 40.1 $599 36% HERS Index: 50 Cooling 0 $0 0% Hot Water 15.3 $0 0% Projected Rating: Based on Plans - Field Confirmation Required. Lights/Appliances 23.2 $1070 64% General Information Photovdtaics -0.0 5-0 -0% Conditioned Area 2186 sq.ft. House Type Single-family detached Service Charges $0 0% Conditioned Volume 28170 cubic ft. Foundation Conditioned basement Bedrooms 3 Mechanical Systems Features Heating: Fuel-fired air distribution,Natural gas,95.0 AFUE. Water Heating: Instant water heater,Propane,0.82 EF,0.0 Gal. Cooling: Air conditioner,Electric,14.5 SEER. Duct Leakage to Outside 22.00 CFM25. Ventilation System Balanced:ERV,52 cfm,24.0 watts. Programmable Thermostat Heat=Yes;Cool=No Building Shell Features Ceiling Flat N/A Slab R-0.0 Edge,R-15.0 Under Sealed Attic N/A Exposed Floor R-41.6 Vaulted Ceiling R-41.6 Window Type U:0.28,SHGC:0.25 TITLE Above Grade Walls R-33.3 Infiltration Rate Htg:2.00 Clg:2.00 ACH50 Company Foundation Walls R-18.0 Method Blower door test Address Lights and Appliance Features City,State,Zip Phone# Percent Interior Lighting 80.00 Range/Oven Fuel Natural gas Fax# Percent Garage Lighting 80.00 Clothes Dryer Fuel Electric Refrigerator(kWh/yr) 575.00 Clothes Dryer EF 3.01 Dishwasher Energy Factor 0.66 Ceiling Fan(cfm/Watt) 0.00 The Home Energy Rating Standard Disclosure for this home is available from the rating provider. REM/Rate-Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. RJ 1985-2013 Architectural Energy Corporation,Boulder,Colorado. rimin (SUBJECT TO ATTACHED CONDITIONS 1 & 2) Permit No. D05-14 Conditions: Driveway Permit In lieu of plan approved by the City Engineer I agree to the following added conditions: 1. I will contact the Department of Public Works and have an inspector check and approve the graded gravel base prior to paving to insure compliance with slope and location; 2. I further agree that if in the inspections, any of the permit conditions are not met that I will at no expense to the City remove and replace the driveway as directed by the City Engineer. By: 1/,r(/' Petitio r nature Name: Murphy Construction/Matt Murphy Address: 329 Southampton Road Westhampton, MA 01027 Note: The Public Works Department recommends that you provide a plan showing the proposed driveway with grades and location in the future to avoid possible expense which you will incur by not getting approval of actual plans in advance. For Commercial and Industrial applicants, a plan showing the proposed driveway with grades, location and Planning Board permits are required. Cc: Building Inspector Permit No. D 05-14 CITY OF NORTHAMPTON, MA DRIVEWAY PERMIT Date: 11/04/13 Check#: 824 FEE: $250.00 THE BOARD OF PUBLIC WORKS Driveway must be staked and house& lot number posted The undersigned respectfully petitions your honorable body for: A new Curb Cut Permission to install a driveway at: 44 Lincoln Avenue, Northampton Fifteen(15) foot maximum width from street line to property line. Gutter drainage not to be disturbed. All drainage shall be directed off the driveway surface to adjacent land and not on the existing roadway. The first one hundred(100)feet of the driveway surface shall be paved as soon as possible if the grade of the proposed driveway exceeds 3% at any point in the first one hundred(100) feet. Homeowners will be held responsible for any costs to the City of Northampton in the event of a washout of this driveway. City is not responsible for culverts installed under driveways in City layout. Code of Ordinances §350-8.8 providing standards for private, individual driveways as most recently amended,must be followed. By: Matt Murphy—Murphy Construction Telephone: 413-237-4415 igna e; Proposed Location Inspection By: I; i. '/e- •7f Gravel Base Grade Inspected By: Final Approval: THE BOARD OF PUBLIC WORKS voted that petition be granted. Edward S. Huntley, P.E. Director of Public Works Cc: Building Inspector o, D ,>g V % h: C!0 Sf ire de-=r-= GJ kruAl IZi 1/ l e re S -15716..crkt , paK-Gwsr p-7L csY1 eitAin City of Northampton - o Massachusetts w clt fg -104 71m DEPARTMENT OF BUILDING INSPECTIONS P= ri :.° 212 Main Street • Municipal Building w ' Northampton, MA 01060 ss '° ti jy �� INSPECTOR Louis Hasbrouck Chuck Miller Building Commissioner Assistant Commissioner HOME OWNER EXEMPTION ACKNOWLEDGEMENT The State of Massachusetts allows the homeowner the right under 780CMR 108.3.4 to act as his/her construction supervisor. The state defines "Homeowner" as, " Person(s) who owns a parcel on which he/she resides or intends to be, a one or two family dwelling, attached or detached structures accessory to such use and/or farm structures. A person who constructs more than one home in a two- year period shall not be considered a home owner." The building department for the City of Northampton wants any person(s)who seek to use the home owner exemption, to act as their own construction supervisor, to be aware that by doing so you become responsible for compliance with state building codes and regulations. The inspection process requires that the building department be called to inspect work at various stages, which include foundation/footings (before backfill), sonotube holes (before pour), a rough building inspection (before work is concealed), insulation inspection (if required) and a final building inspection. The building department requires these inspections before the work is concealed, failure to secure these inspections can result in failure to obtain a certificate of occupancy until the work can be inspected. If the homeowner hires other trades to perform work (electrical, plumbing & gas) the homeowner will be responsible to make sure that the trades hired secure their proper permits in conjunction to the building permit issued, and that they get their required inspections. Failure of the individual trades to secure the permits and inspections as required can DELAY the project until such time as the proper permits and inspections are made I, understand the above. (Home owner/resident's signature requesting exemption) I will call to schedule all required building inspections necessary for the building permit issued to me. Date Address of work location The Commonwealth of Massachusetts Department of Industrial Accidents o.=. Office of Investigations w�:� y, 600 Washington Street "° Boston, MA 02111 'r www.mass.gov/dia iillii Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information //!! S Please Print Legibly Name (Business/Organization/Individual): 14 l r MU2-p It y Ca Ai z Uell04J Address: 397 Sj(J-Si An/Trio yU �• City/State/Zip: 'l/0` PAA 0/6,9- Phone #: y/.3-c3 3 7-414/1 j Are you an employer? Check t e appropriate box: Type of project(required): 1.❑ I am a employer with 4.Pil am a general contractor and I employees (full and/or part-time).* have hired the sub-contractors 6. ew construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. [' Remodeling ship and have no employees These sub-contractors have 8. ❑ Demolition working for me in any capacity. employees and have workers' 9. ❑ Building addition [No workers' comp. insurance comp. insurance.t required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152, §1(4), and we have no employees. [No workers' 13.❑ Other comp. insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. tHo meowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. $Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Qv'-D Div S ,t ,t..,/C 6 eo ip• — Policy#or Self-ins.Lic. #: Al we.... '`Vi, 4 70 3 Expiration Date: 6-1/ -I Job Site Address: 117e Z//Ve2 /4/ /4 tier City/State/Zip: 0?/-/ lU Wj /4 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify un er the pains and i alties of perjury that the information provided above is true and correct. Signature: 1/1 Da te: r� 7 /,3 Phone#: 1//3--dil7f Official use only. Do not write in this area, to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3. City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6. Other Contact Person: Phone#: 6 SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: �i Not Applicable £ Name of License Holder: Alf<1 /If/d2 1 ®b‘, p6. License Number '3029 5-d•nvc/ Fl /rtov ( /-47- a2a/, Address Expiration Date /7(i r/ 3g- yyi s' Signature Telephone 9.sl2egistered Home.Improvement'Contractor Not Applicable £ Company Name Registration Number Address Expiration Date Telephone SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attach- No £ 11. ^Home Owner.Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature, SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House 5i4 Addition ❑ Replacement Windows Alteration(s) Roofing Or Doors D Accessory Bldg. Eg Demolition ❑ New ig s�, Decks [Ea Siding[D] Other[0] 5r' f Brief Description of Proposed. Work: But (1) A1P(J—OuS tAJ 6 4C Iwo( Q 'O-JLr Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 'ea:"ft:New'house and.or addition to existlnq'hous n�,:complete the following: a. Use of building :One Family L- " - Two Family Other b. Number of rooms in each family unit: 2 Number of Bathrooms c. Is there a garage attached? AILI d. Proposed Square footage of new construction. 02'0 0 1 Dimensions 56 .x 06 e. Number of stories? 14-� 5-76,' z / zeZ`Sa Pare-I've-5- f. Method of heating? F t7 i,4r -i/2., Fireplaces or Woodstoves l Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction p057-i- we-n-17 i. Is construction within 100 ft. of wetlands? YesIs construction within 100 yr. floodplain Yes j. Depth of basement or cellar floor below finished grade Cr k. Will building conform to the Building and Zoning regulations? LYes No. • I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, /C` r'" ��✓'� , as Owner of the subject property �j✓f hereby authorize /�"' 7� / '61V4 to act on my b half, in all matters relative to work autilorized by this building permit application. ----�.� 7/-3=73 Signatur f Owner Date / le6cgi , as Owner/Authorized Agent hereby declare that the stata eme s and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. / '�L( ' / Print Name ,14pr ��5-- Signature of Owner/Agent /' Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department tC '� '( - _•Lot Size . __ ' Frontage ._._._ _ _-.._._._ ______.__-_-_.___..-__- ___.___.._.______�.__.____.� Setbacks Front L____1 at L. ' 1 1 1 Side L:!—�1 R:�� L:I yon R:�,� � �I Rear 1_____1 LJ t,,,_j Building Height 1_.__.._] LED I 1 Bldg.Square Footage j Open Space Footage % r1/' (Lot area minus bldg&paved -� �(�, 1 parking) #of Parking Spaces t LT: Fill: i ,._.w ... ..�..�..,:; (volume&Location) — M �' ��5 A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO 0 DONT KNOW 0 YES Q IF YES, date issued:;Set4A- 1$ 2.(:, ,a. IF YES: Was the permit recorded at the Registry of Deeds? NO Q DONT KNOW 0 YES 0 IF YES: enter Book J 1 303 I Pagel Yd. and/or Document#1 i B. Does the site contain a brook, body of water or wetlands? NO 14 DON'T KNOW 0 YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Q Obtained Q , Date Issued: I C. Do any signs exist on the property? YES 0 NO IF YES, describe size, type and location: 1 D. Are there any proposed changes to or additions of signs intended for the property? YES 0 NO IF YES, describe size, type and location: t E. Will the construction activity disturb(clearing, grading, ex avation,or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES Q NO IF YES,then a Northampton Storm Water Management Permit from the DPW is required. • ,1 .- 'S '.c sn_ Depar�rtient�use only- z ti �,� i '—h' NC �'''i t - 'Lv-3' Mrs f f.q ]v r�� i.� l l Y� ig T • � -1,,,!,, fir;' �r tii�ls 1 1,E r ', 1 r \, City of Northampton status ofPermit N ,` 11� 4 p L ,�,I z, i �sf''�`,�t {.3r 1s gi i iii : �i'' ;._ � ' ,Building Department Ctrrla CUt/Drive+ivayFerrrti#'� a y _� ' 212 Main Street Sey+-er/S-epticAva�labiLrt �7' 151 .r !, L ` e `I l 3 20 3 -�' Room 100 1/Vater'/We1CAvailabllltjr ¢, n 'cS No hampton, MA 01060 Two Sets of:Strtictriral Pfaris'h,, 5 ° 1' �_.___-- A S 87-1240 Fax 413-587-1272 Plof/Slte Plan's 1 ' �vr ' '�'�k"� �" 5 -' �;.--\ngi psolOb :_ -,,ri 's ic1�, :, �iy i r t - E L Eleclnc, ptGrl,n Other Specify iii 1 Lai,I S i i 1 it 1 APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office . hf../ �,+rllGO��(/ 1�1(/� Map �� Lot Unit f � L /VD 1214•1 }'t-r✓IP )� )35 Zone Overlay District Elm St.District 'CB::District . SECTION 2.-PROPERTY OWNERSHIP/AUTHORIZED AGENT: 2.1 Owner of Record: dot I K - 6.-1 /6) / Name(Print) Current Mailing Address: Telephone Signature (�y�y6...... ,j�o��7 7y7/ 2.2 Au�tthorriizzed-Agent: , p 1 Name(Print) Current Mailing Address: /1_ iL - ,�-f13-a-37-yvJs Signat `e Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building 02 5—a.. ,O (a)Building Permit Fee 2. Electrical �� (b) Estimated Total Cost of S Construction from(6)' 3. Plumbing /s— aa Building Permit Fee 4. Mechanical(HVAC) /5-;a 190 5. Fire Protection y 6. Total=(1 +2+3+4+5) `it9� DU v Check Number /� o�� y►' This Section For Official`Use•Only r Date Building Permit Number: Issued: Signature: Building•Commissioner/Inspector•of Buildings Date OTC ST F ctitzw i l5-13CPC- � 0 File#BP-2014-0608 t , APPLICANT/CONTACT PERSON MATT MURPHY P n ADDRESS/PHONE 329 SOUTHAMPTON RD WESTHAMPTON (413)237-4415 Q e PROPERTY LOCATION 44 LINCOLN AVE Oy4 1 ��� MAP 25C PARCEL 091 001 ZONE URB(100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid Typeof Construction: CONSTRUCT 2 STORY SFH W/PORCHES&DET GARAGE&RELOCATE DRIVEWAY New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: e ' e � Owner/ Plans/Plot or Plan 066916 �� EiegapN;c ct� 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INF1RMATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission _ Permit DPW Storm Water Management Demo • *ol De . V //r-/ ignaature of Building Official Date Note:Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. 44 LINCOLN AVE BP-2014-0608 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 25C-091 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category:New Single Family House BUILDING PERMIT Permit# BP-2014-0608 Project# JS-2012-001938 Est. Cost: $295000.00 Fee: $1188.80 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: MATT MURPHY 066916 Lot Size(sq. ft.): 8102.16 Owner: SPINK MICHAEL J&THUY T NGUYEN Zoning:URB(100)/ Applicant: MATT MURPHY AT: 44 LINCOLN AVE Applicant Address: Phone: Insurance: 329 SOUTHAMPTON RD (413) 237-4415 0 W ESTHAM PTO N MA01027 ISSUED ON:11/18/2013 0:00:00 TO PERFORM THE FOLLOWING WORK:CONSTRUCT 2 STORY SFH W/PORCHES & DET GARAGE & RELOCATE DRIVEWAY POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 11/18/2013 0:00:00 $1188.80 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner