25C-091 (5) 39. If there is mechanical equipment or a combustible roof, 30 sqft of space, and 30" measured from top of
ceiling joist to bottom of rafters an attic access of minimum RO of 22" x 30" is required to be located in
an accessible place. It must be insulated,gasketed, and secured in place.
Relevant items must be submitted to the building department for approvals before inspections and or
Certificates of Occupancy can be issued.
Feel free to call if you have any questions. My telephone number is 587-1240 and office hours are Monday
through Friday,8:30 am to 4:30 pm,excepting we close for walk-ins at 12:00 noon on Wednesdays. My email
address is: cmiller @northamptonma.gov
Thank you for your cooperation on these matters.
uck i e
City of Northampton
Assistant Commissioner and Zoning Enforcement
24. Drilling or notching of more than 50%of the wall plate width of an exterior wall or load bearing partition
requires a 16 GA 1 1/2" strap across the area and 6" beyond each side with 8-10nd nails. 780 CMR
R602.6.1
25. Dryer ducts must terminate outside of the building, have a backdraft damper,cannot include a screen,
and require 3'clearance from windows.780 CMR M1502.3
26. Dryer duct transition is limited to 8' of aluminum flex, must be exposed, and the proper UL listing.780
CMR M1502.4.3
27. Dryer duct maximum equivalent length is 25' less 5' per 90°elbow or per manufacturer's specs. 780
CMR M1502.4.4.1, no screwed connections.
28. Markup air is required for any exhaust hood of 400 CFM or more.780 CMR M1503.4
29. Fireplaces require all combustion air be provided from the exterior and below the firebox, duct work
maintaining 1" clearance for 5'from the duct outlet for all fireplaces and airtight doors. 2009 IECC
402.4.3
30. Fire and draft stopping shall be completed before rough inspection.Typical locations,top (ceiling)and
bottom (floor) plates, soffits, and every 10'within enclosed cavities. 780 CMR R302.
31. Ignition barriers are required over all thermal plastics and must be in place before final. 780 CMR R316.
32. Dwelling/Garage fire separation.An attached garage (within 3' of main structure) is required to have%"
drywall on the garage side of the separation wall and if there is a finished space above the garage all
walls must have 1/2" drywall and the ceiling 5/8" drywall. 780 CMR R302.6
33. Energy aspects shall comply with the stretch energy code.780 CMR Appendix 115AA or 2009 IECC.
a. An initial HERS evaluation is required including insulation levels anticipated.
b. A final HERS evaluation confirming code requirements have been met including duct testing.
c. A signed copy of the Thermal Bypass Checklist.
d. Energy information including mechanical equipment posted on the electric panel.
e. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy Star
Windows and the Thermal Bypass Checklist. Duct blast testing when practicable.
f. All band joist insulation must be enclosed within an air tight cavity,which you must create.
34. Vapor retarders.Although these are still in the code have exceptions, one must understand that there is
a difference between a vapor retarder or barrier and an air barrier.An air barrier is intended to stop air
flow(convection) a vapor retarder or barrier is intended to stop molecular moisture transfer(diffusion).
A vapor retarder or barrier is effective even if there are some holes or gaps, however an air barrier has
to be absolute and complete. If air can leak through an electrical device or through a crack it follows the
path of least resistance and carries 99%of the moisture in a structure.This is evident every time one
exposes fiberglass insulation and finds black insulation, which is dirt filter out of the air moving through
the insulation. 780 CMR R601.2 for vapor retarders and Table N1102.4.2 for air sealing requirements.
35. Unvented attic assemblies. Hot roofs are allowed, but have specific requirements 780 CMR R806.4.
36. Deck ledgers and post must be appropriately attached, bolts or lags.780 CMR R502.2.2.1 Note:ThruLoks
are engineered for post attachment supporting a railing. Lateral attachment is required for each deck
per section 502.2.2.3.
37. Smoke and CO detectors as required.780 CMR R314 and R315.
a. Smokes in each bedroom,within 10' of a bedroom door,and at the bottom of a stair leading to
a finished floor above.
b. CO within 10'of bedroom doors,at each level,for every 1500 sqft, (plumbing code in the
mechanical room) Except if there are no fossil burning fuels.
c. Heat detector in attached garage, and other large unfinished unconditioned spaces.
38. Closets beneath stair which have doors must be drywalled with 1/2".780 CMR R302.7
11. Steel straps over the ridge or 1x4 minimum collar ties are required 4' OC in the upper 1/3rd780 CMR
R802.3.1
12. Ridge boards must be the full depth of the cut. 780 CMR R802.3.
13. A complete window and header schedule is required.780 CMR Table R502.5 for header sizing and
number of jack studs required.
14. All framing materials which are not code prescriptive must have stamped engineering.
a. LVLs
b. I-joist and or Floor Truss
c. Roof truss
15. A braced wall plan identifying appropriate braced wall areas where required (R301.1) and braced wall
method being used. 780 CMR 602.10.
a. Garage corners and large corner window/door layout may require special solutions.
b. All corners must be appropriately attached to the foundation.
c. When using PFH (R602.10.3.3) or PFG (R602.10.3.4)the nailing requirement is 4" and 3"
respectively using 8d common nails or galvanized box nails. PNEUMATIC nails must be full
headed with the temper and shank sizing meeting the strict code requirement.
16. When nailing sheathing make sure your pneumatic nailers' pressure is properly set. Nails set too deep
perforate the sheathing weakening it and contribute to building damage in high wind events.
17. Ceiling heights minimum 7'for habitable spaces, 6'8"for bathrooms includes tub/shower area if a
shower head is used, 6'8" for basements, 6'4" at beams/ducts. 780 CMR R305.1. MA amended
18. Hazardous glazing locations, within 24" of a door,or within 60" of a stair, or across from hot tubs,spas,
bathtubs within 60" if not 60" above the walking surface, and other locations.780 CMR R308.4
19. Windows over 72" above grade with the opening less than 24 above the finished floor shall meet the 4"
sphere rule.Order restrictors. 780 CMR R612.2
20. Egress and emergency escape requirements shall be strictly met.
a. Basements, habitable attics, and all sleeping rooms require emergency escape.780 CMR R310
b. Windows within 44" of floor, DH 3.3 sqft min window size, Casement 20"x41" exception 5 sqft
at 1st floor. Minimum clear opening 20"x24" or 24"x20". 780 CMR R310.1.1
c. Two doors remote as possible at the normal level of travel, opening measured from the face of
the slab to the stop with door at 90 degrees,one 32" and one 28" minimum 78" high.780 CMR
R311.2
d. Landing at each door 36" out and the width of the door minimum 36", maximum step 7 3/" from
the top of the threshold and only in-swinging doors.780 CMR R311.3
21. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9",
maximum riser 8%", maximum overall variance for the run is 3/8",4" sphere rule on risers except where
the total rise is 30" or less 780 CMR R311.7.4.3 Exception,4 3/8"on balustrade, 6" in the triangle.
Graspable rail 1''4" minimum and 2" maximum rail, height minimum 34" maximum 38", required for 4 or
more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling height from nosing. Rails
must be continuous and returned to the wall if not to newel post.780 CMR R311.7.
22. Guards 36" minimum height above walking surface, a bench is a walking surface, required for more than
30" above floor or grade within 36",4" sphere rule.780 CMR R312.1.
23. Educate the plumber and electrician about maximum notch and hole sizes, and placement.780 CMR
R502.8 and R602.6. In bearing studs holes not larger than 40%of a stud no closer than 5/8 to the edge,
In interior non-bearing studs holes not larger than 60%of a stud no closer than 5/8 to the edge, or holes
in joist are a maximum 1/3 the depth not closer than 2"from the top or bottom or to any other hole.
Notches are different.
City of Northampton
Massachusetts
v
DEPARTMENT OF BUILDING INSPECTIONS o
212 Main Street • Municipal Building b �.
Northampton, MA 01060
INSPECTOR
Matt Murphy November 18, 2013
329 Southampton Road
Westhampton, MA 01027
Subject Location:44 Lincoln Avenue
Map Block: 25C-091
Mr. Murphy,
Your building permit application and plans dated 7-17-13 have been approved as drawn, noted and per this
memo.All changes to the permit plans must be documented.All work must meet all applicable codes
whether noted or not included within this memo.
Please follow up on the following items:
These items will need to be accomplished as the project moves forward and before rough inspections;
1. The floor beam shown for the screen porch in Line 1, Rows E to F appears to be undersized. 2 2x8 12
span with 4' of floor load.
2. The fireplace requires makeup air and sealed glass doors.
3. A smoke and CO detector is required within 10' of the first floor bedroom door.
Note August 16th 2013 begins the newest energy code 2012 IECC with MA amendments with a
concurrency period until July 1,2014 and an expectation that a new Stretch Code will be forth coming.
As of August 4th 2011 the 8th Edition MA code is the 2009 IRC with MA amendments.
In the following are some generic requirements which seem to be problematic.
This is not intended to be comprehensive, nor is it a substitute for purchasing and reading the MA codes.
Read only international codes are available on line at http://publicecodes.cvberregs.com/icod/one
must also consider the MA amendments to these codes which can be found at www.mass.gov/dps/bbrs
The current relevant building codes are:
2009 IBC, 2009 IEBC,2009 IMC, 2009 IRC, 2009 or 2012 IECC,AA115, MA amendments.
1. Structures shall conform to 780 CMR 8th Edition 1 and 2 family building codes with MA amendments.
2. Grading plan for structures being constructed required.780 CMR R401.3 for drainage requirements.
3. A basement drainage system is required in all basements 780 CMR R405.2.3. except those in group I
soils(table R405.1)
4. Foundations that retain earth and enclose interior space require damp proofing 780 CMR R406.1.
5. Through wall form ties must be removed from both faces and patched with hydraulic cement.780 CMR
R406.2 of amendments.
6. Foundation anchor bolts must be%" and be embedded a minimum of 7" into the concrete. 10" bolts!
780 CMR R403.1.6
7. CMU foundations require 3/8" parging before damp proofing.780 CMR R406.1 see exceptions.
8. Emergency escape is required out of every basement whether habitable or not.780 CMR R310.1
9. Crawl spaces can be treated in three different ways,vented (poor idea), exhausted (similar to exhaust
only systems),or treating the space with supply and return.See 780 CMR R408
10. Ceiling joist are intended to prevent spread,once raised above the wall plate they become rafters ties
and may require up sizing of rafters and increased nailing for example with a 4" slope 8-16nd common
are required at each connection. 780 CMR R802.3.1. When there is neither of these a structural ridge is
required with a load path to the foundation.
OQL.._,A t..p CITY OF NORTHAMPTON, MASSACHUSETTS
�" DEPARTMENT OF PUBLIC WORKS
brim) . 125 Locust Street
X30: _, Northampton, MA 01060
b�.
413-587-1570
Fax 413-587-1576
Edward S. Huntley, P.E.
Director
r r`,�~---<. , , l, , ,;�-- _
Q 2u03
November 14, 2013 ,
Mr. Louis Hasbrouck, Building Commissioner °'
212 Main Street, Room 100
Northampton, MA 01060
Dear Mr. Hasbrouck,
Mr. Matt Murphy of 44 Lincoln Avenue,Northampton, MA., asked me to inspect his capped
sewer service. This morning on November, 14, 2013, at 8:00 a.m., we televised the house
service at 44 Lincoln Avenue. There is a piece of black P.V.C. pipe with a screw-on cap. The
pipe goes into what was the dirt floor and attaches to the cast iron pipe leaving the house which
then switches back to clay pipe. It is in good condition. Mr. Murphy was present for the
inspection.
Si erwely�, iva_el
GJ�`�
n Hall
Sewer Department Foreman
Cc: Matt Murphy
file
ti =,r=_;
Citla. of Northampton 1.%1----------------r
$a:J �:, )� _ AA assarlfnstffst=
_ ,4
'—'1 DEPARTMENT OF BUILDING INSPECTIONS -—
INSPECTOR 212 Main Street 0 Municipal Building 7'a.,�
Northampton,MA 01060 WIN
LOCATION 1/1"/ Li it/Co/'/ ,q v T
SQUARE FOOTAGE AMOUNT
BASEMENT @ .20 /07;2 .,9/V. Yo
1ST FLOOR @.50 AO 7? 5-86
2ND FLR @.30 936 .2 80, a''®
%Z FLOORS, FINISH ATTIC,GARAGE @.20 5.76 //� ., o2 0
DECK/PORCHES @ .20 d247 yam' /.0
TOTAL. /13 . FO
ergy
Eite i
insulation Ratings
Ceiling/Roof 44.00
Wall 35.00
Floor/Foundation 15.00
Ductwork(unconditioned spaces):
Glass&boor Rating U-Factor SHGC
Window 0.29 0.28
Door 0.23 0.26
Heating&Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Building Air Leakage and Duct Test Results
Building Air Leakage Test Results
Name of Air Leakage Tester
Duct Tightness Test Results
Name of Duct Tester
Name: Date:
Comments:
Project Title: Spink-Nguyen Residence Report date: 07/18/13
Data filename: C:\Users\rheannon\Documents\REScheck\Spink-Nguyen.rck Page 5 of 5
(a)piping serves more than one dwelling unit,
(b)piping between water heater and kitchen or water heater and distribution manifold,
(c)piping outside conditioned space,buried,or located under a floor slab,
(d)supply and return piping in recirculation systems other than demand recirculation systems,
(e)piping is>3/4 inch nominal diameter,
(f) piping runs>30 feet having 3/8 inch max diameter,
(g)piping runs>20 feet having 1/2 inch max diameter,
(h)piping runs>10 feet having 3/4 inch max diameter,
(i) piping runs>5 feet having max diameter within the run>3/4 inch.
Heating and Cooling Piping Insulation:
❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to R-3.
❑ HVAC piping insulation exposed to outdoor elements is protected from damage and shielded from solar radiation.
Ventilation:
• Ventilation fans satisfy the following efficacy criteria:
(1)Range hoods and in-line fan:2.8 cfm/watt.
(2)Bath-/utility room with rated cfm>=10>and<90: 1.4 cfm/watt.
(3)Bath-/utility room with rated minimum cfm>=90:2.8 cfm/watt.
Swimming Pools and In-ground Spas:
❑ Heaters have an readily accessible on-off switch.
o Heaters operating on natural gas or LPG have an electronic pilot light.
D Schedule-capable automatic on-off timer switches are installed on heaters and pumps.
Exceptions:
Where public health standards require continuous pump operation.
Where pumps operate within solar-and/or waste-heat-recovery systems.
Heated pools and spas have a vapor retardant cover.
Exceptions:
Covers are not required when 70%of the heating energy is from site-recovered energy or solar energy source.
Lighting Requirements:
❑ Within permanently installed fixtures,75 percent contain only lamps that can be categorized as one of the following.Or,a minimum of
75 percent of all lamps within permanent fixtures can be categorized as one of the following:
(a)Compact fluorescent
(b)T-8 or smaller diameter linear fluorescent
(c)40 lumens per watt for lamp wattage<=15
(d)50 lumens per watt for lamp wattage>15 and<=40
(e)60 lumens per watt for lamp wattage>40
Exceptions:
Low voltage lighting systems.
❑ Fuel gas lighting systems have electronic pilot lights.
Other Requirements:
❑ Snow-and ice-melting systems with energy supplied from the service to a building shall include automatic controls capable of shutting
off the system when a)the pavement temperature is above 50 degrees F,b)no precipitation is falling,and c)the outdoor temperature is
above 40 degrees F(a manual shutoff control is also permitted to satisfy requirement'c').
Certificate:
❑ A permanent certificate is provided on or in the electrical distribution panel listing the predominant insulation R-values;window
U-factors;type and efficiency of space-conditioning and water heating equipment;and results from any required duct system and
building envelope air leakage testing.The certificate#does not cover or obstruct the visibility of the circuit directory label,service
disconnect label or other required labels.
NOTES TO FIELD:(Building Department Use Only)
Project Title: Spink-Nguyen Residence Report date: 07/18/13
Data filename: C:\Users\rheannon\Documents\REScheck\Spink-Nguyen.rck Page 4 of 5
o Insulation in floors(including above garage and cantilevered floors)is installed to maintain permanent contact with underside of subfloor
decking.Exterior insulation for framed walls is in substantial contact and continuous alignment with the air barrier.Crawl space wall
insulation installed in lieu of floor insulation is permanently attached to crawlspace walls. Inspection of log walls is in accordance with
the provisions of ICC-400.
o Spaces between fenestration jambs and framing and skylights and framing are sealed.Batts in narrow cavities are cut to fit;or narrow
cavities are filled with insulation that readily fills the available cavity space.
p Exposed earth in unvented crawl spaces is covered with Class I vapor retarder with overlapping joints taped.
o Air sealing is installed between the garage and conditioned spaces.
D Exterior walls adjacent to showers and tubs are insulated and have air barrier separating the wall from the shower and tubs.
o Access openings,drop down stairs or knee wall doors to unconditioned attic spaces are insulated and sealed.
p Recessed light fixtures installed in the building thermal envelope are IC rated,airtight labeled at air leakage rate<=2.0 cfm,and sealed
to the drywall with gasket or caulk.
• Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space are air sealed.
j Plumbing and Wiring:Insulation is placed between the exterior of the wall assembly and pipes.Batt insulation is cut and fitted around
wiring and plumbing,or for insulation that on installation readily conforms to available space such insulation shall fill all space between
wall and piping/wiring.
o Air barrier extends behind electrical or communication boxes or,air sealed type boxes are installed.
D HVAC register boots that penetrate building thermal envelope are sealed to subfloor or drywall.
Li Fireplace walls have air barrier and closure doors are gasketed.
Sunrooms:
D Sunrooms that are NOT thermally isolated from the building envelope meet the requirements applicable to the building envelope.
Materials Identification and Installation:
D Materials and equipment are installed in accordance with the manufacturer's installation instructions.
• Materials and equipment are identified so that compliance can be determined.
Li Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
o Insulation R-values and glazing U-factors are clearly marked on the building plans or specifications.
Duct Insulation:
j Supply ducts in attics are insulated to a minimum of R-8.All other ducts in unconditioned spaces or outside the building envelope are
insulated to at least R-6.
Duct Construction and Testing:
Li Building framing cavities are not used as ducts or plenums.
o All joints and seams of air ducts,air handlers,and filter boxes are substantially airtight by means of tapes,mastics,liquid sealants,
gasketing or other approved closure systems.Tapes,mastics,and fasteners are rated UL 181A or UL 181B and are labeled according
to the duct construction.Metal duct connections with equipment and/or fittings are mechanically fastened.Crimp joints for round metal
ducts have a contact lap of at least 1 1/2 inches and are fastened with a minimum of three equally spaced sheet-metal screws.
Exceptions:
Joint and seams covered with air-impermeable spray foam.
Where a partially inaccessible duct connection exists,mechanical fasteners can be equally spaced on the exposed portion of the
joint so as to prevent a hinge effect.
Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa).
o All ducts and air handlers are located within conditioned space.
Temperature Controls:
• Where the primary heating system is a forced air-furnace,at least one programmable thermostat is installed to control the primary
heating system and has set-points initialized at 70 degree F for the heating cycle and 78 degree F for the cooling cycle.
o Heat pumps having supplementary electric-resistance heat have controls that prevent supplemental heat operation when the
compressor can meet the heating load.
Heating and Cooling Equipment Sizing:
o Equipment is sized in accordance with ACCA Manual S based on building loads calculated in accordance with ACCA Manual J or other
approved heating and cooling calculation methodologies.
❑ For systems serving multiple dwelling units documentation has been submitted demonstrating compliance with 2012 IECC Commercial
Building Mechanical and/or Service Water Heating(Sections C403 and C404).
Circulating Service Hot Water Systems:
Li Systems include an automatic or accessible manual switch to turn off the circulating pump when the system is not in use.
u Pipes are insulated to R-3 when any one of the following apply:
Project Title: Spink-Nguyen Residence Report date: 07/18/13
Data filename:C:\Users\rheannon\Documents\REScheck\Spink-Nguyen.rck Page 3 of 5
REScheck Software Version 4.4.4
Inspection Checklist
Energy Code: 2012 IECC
Location: Northampton, Massachusetts
Construction Type: Single Family
Project Type: New construction
Building Orientation: Bldg.faces 180 deg.from North
Glazing Area Percentage: 14%
Heating Degree Days: 6404
Climate Zone: 5
Ceilings:
❑ Ceiling 1:Cathedral Ceiling,R-44.0 cavity insulation
Comments:
Above-Grade Walls:
❑ Wall 1:Wood Frame,24"o.c.,R-35.0 cavity insulation
Comments:
Basement Walls:
❑ Basement Wall 1:Solid Concrete or Masonry,7.3'ht/5.5'bg/7.3'insul,R-15.0 continuous insulation
Comments:
Windows:
❑ Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.289
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Doors:
❑ Door 1:Solid,U-factor:0.330
Comments:
This door is exempt from the U-factor requirement.
❑ Door 2:Glass,U-factor:0.300
Comments:
❑ Door 3:Solid,U-factor:0.230
Comments:
Floors:
❑ Floor 1:Slab-On-Grade:Unheated,5.5'insulation depth,R-15.0 continuous insulation
Comments:
Slab insulation extends down from the top of the slab to at least 5.5 ft.OR down to at least the bottom of the slab then horizontally for a
total distance of 5.5 ft.
Air Leakage:
❑ Building envelope air tightness complies by a post rough-in blower door test result of less than 3 ACH at 50 pascals.
❑ Automatic or gravity dampers are installed on all outdoor air intakes and exhausts.
❑ Wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air.
Air Barrier,Sealing,and Insulation Installation Criteria: •.'
Ci A continuous air barrier is installed in the building envelope including rim joists and exposed edges of insulation.Breaks or joints in the
air barrier are sealed.Air permeable insulation is not used as a sealing material.
❑ Junction of foundation and wall sill plates,wall top plate and top of wall,sill plate and rim-band,and rim band and subfloor are sealed.
Corners,headers,and rim joists making up the thermal envelope are insulated.
Project Title: Spink-Nguyen Residence Report date: 07/18/13
Data filename: C:\Users\rheannon\Documents\REScheck\Spink-Nguyen.rck Page 2 of 5
1
4CREScheck Software Version 4.4.4
.. 1 Compliance Certificate
Project Title: Spink-Nguyen Residence
Energy Code: 2012 IECC
Location: Northampton, Massachusetts
Construction Type: Single Family
Project Type: New construction
Building Orientation: Bldg.faces 180 deg.from North
Glazing Area Percentage: 14%
Heating Degree Days: 6404
Climate Zone: 5
Construction Site: Owner/Agent: Designer/Contractor:
44 Lincoln Ave Michael and Thuy Spink-Nguyen Rheannon DeMond
Northampton,MA 01060 44 Lincoln Avenue Benson Woodworking Company, Inc.
Northampton,MA 01060 6 Blackjack Crossing Road
Walpole,NH 03608
603-756-3600
rheannon @bensonwood.com
"t8��.. � � ijkiitte-off � ��'� � y��i it ii..,,h;� � ��. <n %e„ �, d��„, .�,,,,o .,
Compliance:12.8%Better Than Code Maximum UA:453 Your UA:395
The%Better or Worse Than Code index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Gross Cavity Cont. Glazing UA
Assembly Area or R-Value R-Value or Door
Perimeter U-Factor
Ceiling 1:Cathedral Ceiling 1398 44.0 0.0 34
Wall 1:Wood Frame,24"o.c. 2201 35.0 0.0 78
Orientation:Unspecified
Window 1:Wood Frame:Double Pane with Low-E 272 0.289 79
SHGC:0.28
Orientation:Unspecified
Door 1:Solid 26 0.330 9
Orientation:Unspecified
Door 2:Glass 41 0.300 12
SHGC:0.26
Orientation:Unspecified
Door 3:Solid 44 0.230 10
Orientation:Unspecified
Basement Wall 1:Solid Concrete or Masonry 1362 0.0 15.0 68
Orientation:Unspecified
Wall height:7.3'
Depth below grade:5.5'
Insulation depth:7.3'
Floor 1:Slab-On-Grade:Unheated 160 15.0 105
Insulation depth:5.5'
Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2012 IECC requirements in
REScheck Version 4.4.4 and to comply with the mandatory requirements listed e -' S he, Inspection Checklist.
tea, n .�-�
Name-Title Signa •re j '„�roY , Da e
/�`�,;Gp. S .4e, C),
PL'i.20.981
Project Title: Spink-Nguyen Residence \ -ff��• Report date: 07/18/13
Data filename: C:\Users\rheannon\Documents\REScheck\Spink-Nguyen.rck Page 1 of 5
MUNICIPAL WATER AVAILABILITY APPLICATION
Northampton Water Department
237 Prospect St.
Northampton,MA 01060
587-1097
A Department of Public Works Trench Permit shall be required prior to any construction or
connection activity associated with this application.
Location:
44 Lincoln Avenue
Inquiry Made By:
Matt Murphy 237-4415 Demo/rebuild
Date of Inquiry: 11/04/13
Number of Type of Single Family X Type of Private X
Units: 1 Unit(s): Apart. Comm Ownership: Condo
Multi-family Rental
(Applicant to fill out the above)
Municipal Water Main in
Existing service to
Front of Location? Yes: X No: site? Yes: X No
Size of Water Main: 6" Material: Cast Iron Age: 1934
Approximate Static Street Flow Test Conducted: Yes: No: X
Pressure: 110psi If done attach results
Size of Service Connection 3/4" Existing
Suggested Meter Size: 5/8
Comments: The Water Department cannot guarantee adequate water pressure during peak demand
times at elevations above 320 feet. Contractor to utilize existing service.
• A corresponding water entrance fee shall be paid prior to making any connection to the municipal water
system.
• Arrangements of such installation shall be made with the Northampton Water Department with a minimum
of ing days notificati•-
•,_: All work hall con . Nirthampton Water Department specifications.
David W. Sparks, Superintendent of Water Dept.
Water Entry$N/A Meter$N/A Radio $N/A
cc: Ned Huntley,Director
cc: Louis Hasbrouck,Building Commissioner
Note: If this availability is for a new construction,it must be hand delivered to the Building
Inspector.
,srnb I.admin`,.Pennits`'Vater Application Water Availabilit�.doe
MUNICIPAL SEWER/AVAILABILITY APPLICATION
Northampton Streets Department
125 Locust Street
Northampton, MA 01060
587-1570
A Department of Public Works Trench Permit and Sewer Entry Permit shall be required
prior to any construction or connection activity associated with this application.
Location: 44 Lincoln Avenue
Inquiry Made By: ,r Tom Fenton , Duffy Willard Paving 586-1477 C rac4or
� ',t '^ Z-37-'1415
Date of Inquiry: "�^�`f' 11/04/13
Reason for
Request: Demolition of Old Home and Rebuilding would like to hook into sewer
Municipal Sewer Main in Front of Location: Yes >c No
Municipal Storm Drain Available: 5'/2 deep Yes x No
Size of Sewer Main: R ' Material: CZ-AY Age: L 8 ?ok
Depth of Sewer Main: 6 rz-
Length of Sewer Main: q is
Size of Service Connection: V 111 K A/ CcJ /./
Type of Service Connection:
Tie-in to Sanitary Main Tie-in to Sanitary Stub
Comments:
Note: If this availibilitv is for new construction,this form must be hand delivered to Building
Inspector.
A corresponding"sewer entrance fee"shall be paid prior to making any connection to the municipal sewer
system.Arrangements of such installation shall be made with the Northampton Streets Department with a
minimum of 5 working days notification. All work shall conform to Northampton Streets Department
specifications.
CI /Zit
John Hall
Sewer Department
cc: Ned Huntley, Director DPW
Louis Hasbrouck, Building Commissioner
Home Energy Rating Certificate
44 Lincoln Ave
Northampton,MA 01060
Estimated Annual Energy Cost
, A A A
5 Stars Plus Use MMBtu Cost Percent
Projected Rating Heating 40.1 $599 36%
HERS Index: 50 Cooling 0 $0 0%
Hot Water 15.3 $0 0%
Projected Rating: Based on Plans - Field Confirmation Required. Lights/Appliances 23.2 $1070 64%
General Information Photovdtaics -0.0 5-0 -0%
Conditioned Area 2186 sq.ft. House Type Single-family detached Service Charges $0 0%
Conditioned Volume 28170 cubic ft. Foundation Conditioned basement
Bedrooms 3
Mechanical Systems Features
Heating: Fuel-fired air distribution,Natural gas,95.0 AFUE.
Water Heating: Instant water heater,Propane,0.82 EF,0.0 Gal.
Cooling: Air conditioner,Electric,14.5 SEER.
Duct Leakage to Outside 22.00 CFM25.
Ventilation System Balanced:ERV,52 cfm,24.0 watts.
Programmable Thermostat Heat=Yes;Cool=No
Building Shell Features
Ceiling Flat N/A Slab R-0.0 Edge,R-15.0 Under
Sealed Attic N/A Exposed Floor R-41.6
Vaulted Ceiling R-41.6 Window Type U:0.28,SHGC:0.25 TITLE
Above Grade Walls R-33.3 Infiltration Rate Htg:2.00 Clg:2.00 ACH50 Company
Foundation Walls R-18.0 Method Blower door test Address
Lights and Appliance Features City,State,Zip
Phone#
Percent Interior Lighting 80.00 Range/Oven Fuel Natural gas Fax#
Percent Garage Lighting 80.00 Clothes Dryer Fuel Electric
Refrigerator(kWh/yr) 575.00 Clothes Dryer EF 3.01
Dishwasher Energy Factor 0.66 Ceiling Fan(cfm/Watt) 0.00
The Home Energy Rating Standard Disclosure for this home is available from the rating provider.
REM/Rate-Residential Energy Analysis and Rating Software v14.3
This information does not constitute any warranty of energy cost or savings.
RJ 1985-2013 Architectural Energy Corporation,Boulder,Colorado.
rimin
(SUBJECT TO ATTACHED CONDITIONS 1 & 2)
Permit No. D05-14
Conditions: Driveway Permit
In lieu of plan approved by the City Engineer I agree to the following added conditions:
1. I will contact the Department of Public Works and have an inspector check and approve
the graded gravel base prior to paving to insure compliance with slope and location;
2. I further agree that if in the inspections, any of the permit conditions are not met that I
will at no expense to the City remove and replace the driveway as directed by the City
Engineer.
By: 1/,r(/'
Petitio r nature
Name: Murphy Construction/Matt Murphy
Address: 329 Southampton Road
Westhampton, MA 01027
Note: The Public Works Department recommends that you provide a plan showing the
proposed driveway with grades and location in the future to avoid possible expense
which you will incur by not getting approval of actual plans in advance.
For Commercial and Industrial applicants, a plan showing the proposed driveway with
grades, location and Planning Board permits are required.
Cc: Building Inspector
Permit No. D 05-14
CITY OF NORTHAMPTON, MA
DRIVEWAY PERMIT
Date: 11/04/13
Check#: 824
FEE: $250.00
THE BOARD OF PUBLIC WORKS
Driveway must be staked and house& lot number posted
The undersigned respectfully petitions your honorable body for: A new Curb Cut
Permission to install a driveway at: 44 Lincoln Avenue, Northampton
Fifteen(15) foot maximum width from street line to property line. Gutter drainage not to be
disturbed. All drainage shall be directed off the driveway surface to adjacent land and not on the
existing roadway. The first one hundred(100)feet of the driveway surface shall be paved as
soon as possible if the grade of the proposed driveway exceeds 3% at any point in the first one
hundred(100) feet. Homeowners will be held responsible for any costs to the City of
Northampton in the event of a washout of this driveway. City is not responsible for culverts
installed under driveways in City layout. Code of Ordinances §350-8.8 providing standards for
private, individual driveways as most recently amended,must be followed.
By: Matt Murphy—Murphy Construction
Telephone: 413-237-4415
igna e;
Proposed Location Inspection By: I; i. '/e- •7f
Gravel Base Grade Inspected By:
Final Approval:
THE BOARD OF PUBLIC WORKS voted that petition be granted.
Edward S. Huntley, P.E.
Director of Public Works
Cc: Building Inspector
o, D ,>g V % h: C!0 Sf ire de-=r-= GJ kruAl
IZi 1/ l e re S -15716..crkt , paK-Gwsr p-7L csY1 eitAin
City of Northampton -
o
Massachusetts w clt
fg -104 71m
DEPARTMENT OF BUILDING INSPECTIONS P= ri
:.° 212 Main Street • Municipal Building
w ' Northampton, MA 01060 ss '° ti
jy ��
INSPECTOR
Louis Hasbrouck Chuck Miller
Building Commissioner Assistant Commissioner
HOME OWNER EXEMPTION ACKNOWLEDGEMENT
The State of Massachusetts allows the homeowner the right under 780CMR 108.3.4 to act as his/her
construction supervisor. The state defines "Homeowner" as, " Person(s) who owns a parcel on which
he/she resides or intends to be, a one or two family dwelling, attached or detached structures
accessory to such use and/or farm structures. A person who constructs more than one home in a two-
year period shall not be considered a home owner."
The building department for the City of Northampton wants any person(s)who seek to use the home
owner exemption, to act as their own construction supervisor, to be aware that by doing so you
become responsible for compliance with state building codes and regulations. The inspection
process requires that the building department be called to inspect work at various stages, which include
foundation/footings (before backfill), sonotube holes (before pour), a rough building inspection
(before work is concealed), insulation inspection (if required) and a final building inspection.
The building department requires these inspections before the work is concealed, failure to secure
these inspections can result in failure to obtain a certificate of occupancy until the work can be
inspected.
If the homeowner hires other trades to perform work (electrical, plumbing & gas) the homeowner will be
responsible to make sure that the trades hired secure their proper permits in conjunction to the building
permit issued, and that they get their required inspections. Failure of the individual trades to secure
the permits and inspections as required can DELAY the project until such time as the proper permits
and inspections are made
I, understand the above.
(Home owner/resident's signature requesting exemption)
I will call to schedule all required building inspections necessary for the building permit issued to me.
Date
Address of work location
The Commonwealth of Massachusetts
Department of Industrial Accidents
o.=. Office of Investigations
w�:� y, 600 Washington Street
"° Boston, MA 02111
'r www.mass.gov/dia
iillii Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers
Applicant Information //!! S Please Print Legibly
Name (Business/Organization/Individual): 14 l r MU2-p It y Ca Ai z Uell04J
Address: 397 Sj(J-Si An/Trio yU �•
City/State/Zip: 'l/0` PAA 0/6,9- Phone #: y/.3-c3 3 7-414/1 j
Are you an employer? Check t e appropriate box: Type of project(required):
1.❑ I am a employer with 4.Pil am a general contractor and I
employees (full and/or part-time).* have hired the sub-contractors 6. ew construction
2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. [' Remodeling
ship and have no employees These sub-contractors have 8. ❑ Demolition
working for me in any capacity. employees and have workers' 9. ❑ Building addition
[No workers' comp. insurance comp. insurance.t
required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions
3.❑ I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions
myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs
insurance required.] t c. 152, §1(4), and we have no
employees. [No workers' 13.❑ Other
comp. insurance required.]
*Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information.
tHo meowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such.
$Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have
employees. If the sub-contractors have employees,they must provide their workers'comp.policy number.
I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site
information.
Insurance Company Name: Qv'-D Div S ,t ,t..,/C 6 eo ip• —
Policy#or Self-ins.Lic. #: Al we.... '`Vi, 4 70 3 Expiration Date: 6-1/ -I
Job Site Address: 117e Z//Ve2 /4/ /4 tier City/State/Zip: 0?/-/ lU Wj /4
Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date).
Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a
fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine
of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of
Investigations of the DIA for insurance coverage verification.
I do hereby certify un er the pains and i alties of perjury that the information provided above is true and correct.
Signature: 1/1 Da te: r� 7 /,3
Phone#: 1//3--dil7f
Official use only. Do not write in this area, to be completed by city or town official
City or Town: Permit/License#
Issuing Authority(circle one):
1.Board of Health 2.Building Department 3. City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector
6. Other
Contact Person: Phone#:
6
SECTION 8-CONSTRUCTION SERVICES
8.1 Licensed Construction Supervisor:
�i Not Applicable £
Name of License Holder: Alf<1 /If/d2 1 ®b‘, p6.
License Number
'3029 5-d•nvc/ Fl /rtov ( /-47- a2a/,
Address Expiration Date
/7(i r/ 3g- yyi s'
Signature Telephone
9.sl2egistered Home.Improvement'Contractor Not Applicable £
Company Name Registration Number
Address Expiration Date
Telephone
SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6))
Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result
in the denial of the issuance of the building permit.
Signed Affidavit Attach- No £
11. ^Home Owner.Exemption
The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families
and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts
as supervisor.CMR 780, Sixth Edition Section 108.3.5.1.
Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there
is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm
structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner.
Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be
responsible for all such work performed under the building permit.
As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon
completion of the work for which this permit is issued.
Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153 (Liability of Employers to
Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s)
you hire to perform work for you under this permit.
The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of
Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated.
Homeowner Signature,
SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable)
New House 5i4 Addition ❑ Replacement Windows Alteration(s) Roofing
Or Doors D
Accessory Bldg. Eg Demolition ❑ New ig s�, Decks [Ea Siding[D] Other[0]
5r' f
Brief Description of Proposed.
Work: But (1) A1P(J—OuS tAJ 6 4C Iwo( Q 'O-JLr
Alteration of existing bedroom Yes No Adding new bedroom Yes No
Attached Narrative Renovating unfinished basement Yes No
Plans Attached Roll -Sheet
'ea:"ft:New'house and.or addition to existlnq'hous n�,:complete the following:
a. Use of building :One Family L- " - Two Family Other
b. Number of rooms in each family unit: 2 Number of Bathrooms
c. Is there a garage attached? AILI
d. Proposed Square footage of new construction. 02'0 0 1 Dimensions 56 .x 06
e. Number of stories? 14-� 5-76,' z /
zeZ`Sa Pare-I've-5-
f. Method of heating? F t7 i,4r -i/2., Fireplaces or Woodstoves l Number of each
g. Energy Conservation Compliance. Masscheck Energy Compliance form attached?
h. Type of construction p057-i- we-n-17
i. Is construction within 100 ft. of wetlands? YesIs construction within 100 yr. floodplain Yes
j. Depth of basement or cellar floor below finished grade
Cr
k. Will building conform to the Building and Zoning regulations? LYes No. •
I. Septic Tank City Sewer Private well City water Supply
SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN
OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT
I, /C` r'" ��✓'� , as Owner of the subject
property �j✓f
hereby authorize /�"' 7� / '61V4
to act on my b half, in all matters relative to work autilorized by this building permit application.
----�.� 7/-3=73
Signatur f Owner Date
/ le6cgi , as Owner/Authorized
Agent hereby declare that the stata eme s and information on the foregoing application are true and accurate,to the best of my knowledge
and belief.
Signed under the pains and penalties of perjury.
/
'�L( ' /
Print Name
,14pr ��5--
Signature of Owner/Agent /' Date
Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information
Existing Proposed Required by Zoning
This column to be filled in by
Building Department
tC '� '( - _•Lot Size . __ '
Frontage ._._._ _ _-.._._._ ______.__-_-_.___..-__- ___.___.._.______�.__.____.�
Setbacks Front L____1 at L.
' 1 1 1
Side L:!—�1 R:�� L:I yon R:�,� � �I
Rear 1_____1 LJ t,,,_j
Building Height 1_.__.._] LED I 1
Bldg.Square Footage j
Open Space Footage % r1/'
(Lot area minus bldg&paved -� �(�, 1
parking)
#of Parking Spaces
t LT:
Fill: i ,._.w ... ..�..�..,:;
(volume&Location) — M �' ��5
A. Has a Special Permit/Variance/Finding ever been issued for/on the site?
NO 0 DONT KNOW 0 YES Q
IF YES, date issued:;Set4A- 1$ 2.(:, ,a.
IF YES: Was the permit recorded at the Registry of Deeds?
NO Q DONT KNOW 0 YES 0
IF YES: enter Book J 1 303 I Pagel Yd. and/or Document#1 i
B. Does the site contain a brook, body of water or wetlands? NO 14 DON'T KNOW 0 YES 0
IF YES, has a permit been or need to be obtained from the Conservation Commission?
Needs to be obtained Q Obtained Q , Date Issued: I
C. Do any signs exist on the property? YES 0 NO
IF YES, describe size, type and location: 1
D. Are there any proposed changes to or additions of signs intended for the property? YES 0 NO
IF YES, describe size, type and location: t
E. Will the construction activity disturb(clearing, grading, ex avation,or filling)over 1 acre or is it part of a common plan
that will disturb over 1 acre? YES Q NO
IF YES,then a Northampton Storm Water Management Permit from the DPW is required.
•
,1 .- 'S '.c sn_ Depar�rtient�use only- z ti �,� i
'—h' NC �'''i t - 'Lv-3' Mrs f f.q ]v r�� i.� l l Y� ig T
• � -1,,,!,, fir;' �r tii�ls 1 1,E r ', 1 r
\, City of Northampton status ofPermit N
,` 11� 4 p L ,�,I z, i �sf''�`,�t {.3r 1s gi i iii : �i'' ;._ �
' ,Building Department Ctrrla CUt/Drive+ivayFerrrti#'� a y _� '
212 Main Street Sey+-er/S-epticAva�labiLrt �7' 151 .r !, L ` e
`I l 3 20 3 -�' Room 100 1/Vater'/We1CAvailabllltjr ¢, n 'cS
No hampton, MA 01060 Two Sets of:Strtictriral Pfaris'h,, 5 ° 1'
�_.___-- A S 87-1240 Fax 413-587-1272 Plof/Slte Plan's 1 ' �vr ' '�'�k"� �" 5 -'
�;.--\ngi psolOb :_ -,,ri 's ic1�, :, �iy i r t - E L
Eleclnc, ptGrl,n Other Specify iii 1 Lai,I S i i 1 it 1
APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING
SECTION 1 -SITE INFORMATION
1.1 Property Address: This section to be completed by office
.
hf../ �,+rllGO��(/ 1�1(/� Map �� Lot Unit
f
� L
/VD 1214•1 }'t-r✓IP )� )35 Zone Overlay District
Elm St.District 'CB::District .
SECTION 2.-PROPERTY OWNERSHIP/AUTHORIZED AGENT:
2.1 Owner of Record:
dot I K - 6.-1 /6) /
Name(Print) Current Mailing Address:
Telephone
Signature (�y�y6...... ,j�o��7
7y7/
2.2 Au�tthorriizzed-Agent: , p 1
Name(Print) Current Mailing Address:
/1_ iL - ,�-f13-a-37-yvJs
Signat `e Telephone
SECTION 3-ESTIMATED CONSTRUCTION COSTS
Item Estimated Cost(Dollars)to be Official Use Only
completed by permit applicant
1. Building 02 5—a.. ,O (a)Building Permit Fee
2. Electrical �� (b) Estimated Total Cost of
S Construction from(6)'
3. Plumbing /s— aa Building Permit Fee
4. Mechanical(HVAC) /5-;a 190
5. Fire Protection y
6. Total=(1 +2+3+4+5) `it9� DU v Check Number /� o��
y►' This Section For Official`Use•Only r
Date
Building Permit Number: Issued:
Signature:
Building•Commissioner/Inspector•of Buildings Date
OTC ST F ctitzw i l5-13CPC- � 0
File#BP-2014-0608 t
,
APPLICANT/CONTACT PERSON MATT MURPHY P n
ADDRESS/PHONE 329 SOUTHAMPTON RD WESTHAMPTON (413)237-4415 Q
e
PROPERTY LOCATION 44 LINCOLN AVE Oy4 1 ���
MAP 25C PARCEL 091 001 ZONE URB(100)/
THIS SECTION FOR OFFICIAL USE ONLY:
PERMIT APPLICATION CHECKLIST
ENCLOSED REQUIRED DATE
ZONING FORM FILLED OUT
Fee Paid
Building Permit Filled out
Fee Paid
Typeof Construction: CONSTRUCT 2 STORY SFH W/PORCHES&DET GARAGE&RELOCATE
DRIVEWAY
New Construction
Non Structural interior renovations
Addition to Existing
Accessory Structure
Building Plans Included: e ' e
�
Owner/ Plans/Plot or Plan 066916 �� EiegapN;c ct�
3 sets of Plans/Plot Plan
THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON
INF1RMATION PRESENTED:
Approved Additional permits required(see below)
PLANNING BOARD PERMIT REQUIRED UNDER:§
Intermediate Project: Site Plan AND/OR Special Permit With Site Plan
Major Project: Site Plan AND/OR Special Permit With Site Plan
ZONING BOARD PERMIT REQUIRED UNDER: §
Finding Special Permit Variance*
Received&Recorded at Registry of Deeds Proof Enclosed
Other Permits Required:
Curb Cut from DPW Water Availability Sewer Availability
Septic Approval Board of Health Well Water Potability Board of Health
Permit from Conservation Commission Permit from CB Architecture Committee
Permit from Elm Street Commission _ Permit DPW Storm Water Management
Demo • *ol De .
V //r-/
ignaature of Building Official Date
Note:Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning
requirements and obtain all required permits from Board of Health,Conservation Commission,Department
of public works and other applicable permit granting authorities.
*Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of
Planning&Development for more information.
44 LINCOLN AVE BP-2014-0608
GIS#: COMMONWEALTH OF MASSACHUSETTS
Map:Block: 25C-091 CITY OF NORTHAMPTON
Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
Category:New Single Family House BUILDING PERMIT
Permit# BP-2014-0608
Project# JS-2012-001938
Est. Cost: $295000.00
Fee: $1188.80 PERMISSION IS HEREBY GRANTED TO:
Const. Class: Contractor: License:
Use Group: MATT MURPHY 066916
Lot Size(sq. ft.): 8102.16 Owner: SPINK MICHAEL J&THUY T NGUYEN
Zoning:URB(100)/ Applicant: MATT MURPHY
AT: 44 LINCOLN AVE
Applicant Address: Phone: Insurance:
329 SOUTHAMPTON RD (413) 237-4415 0
W ESTHAM PTO N MA01027 ISSUED ON:11/18/2013 0:00:00
TO PERFORM THE FOLLOWING WORK:CONSTRUCT 2 STORY SFH W/PORCHES & DET
GARAGE & RELOCATE DRIVEWAY
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter:
Footings:
Rough: Rough: House# Foundation:
Driveway Final:
Final: Final:
Rough Frame:
Gas: Fire Department Fireplace/Chimney:
Rough: Oil: Insulation:
Final: Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Certificate of Occupancy Signature:
FeeType: Date Paid: Amount:
Building 11/18/2013 0:00:00 $1188.80
212 Main Street,Phone(413)587-1240,Fax: (413)587-1272
Louis Hasbrouck—Building Commissioner