Loading...
38A-145 + _Ciir of ozittttp#o - 1 )� j a55ar4tasette _ =� __ - • ' ' DEPARTMENT OF BUILDDZG INSPECTIONS ~ _ INSPECTOR 212 Main Street • Municipal Building �;- ,�' Northampton,MA 01060 r 5 6?LOCATION t‘uire4/ SQUARE FOOTAGE AMOUNT BASEMENT @ 20 I ( 1 " 6:e9 e9 G 1ST FLOOR @.50 I 1 Tb 3e-y6- 2ND FLR @.30 • l- 02 3 '1 mo o 'A FLOORS, FINISH ATTIC,GARAGE @.20 SZE /d 5' ( 6 DECK/PORCHES @ :20 77i'io -� 'O TOTAL. $ /) 1193. Va • P ELECTRICAL Homes have a 200 AMP service and are wired with smoke and heat detectors as per code. The exterior light fixtures are provided. The lighting allowance is $500 for the remainder of the lights. ENERGY EFFICIENCY AND COMFORT The home will be built to a Zero Energy Home standard for energy efficiency and comfort. A Home Energy Rating System (HERS) index of less that 10 should be attained(the home as modeled will generate more than 90% of its own energy usage as compared to a reference home built to code in the state of Massachusetts). The home will be certified to be more comfortable and less expensive to maintain, saving on the typical annual heating, cooling and electricity costs. HOMES ENERGY GENERATION An 8.25 kW electric generation system(photovoltaic or PV for short)will be installed on the roof. The buyer may purchase the system directly (at additional costs)or lease the system. If the system is purchased the buyer is entitled to the Federal and State tax credits. HOME WIRING SYSTEM All homes have an electronic base starting with a Service Center that distributes Audio/Visual service from outside the house (cable TV, telephone, Internet, etc.)to locations in the house. This is composed of high performance cables(RG-6 quad shielded and CAT 5 wire) installed to transmit high-speed Internet, digital phone and TV (Phone/Data lines: one in the master bedroom and one in the family room; Cable lines in the bedrooms and in the family room). INTERIOR TRIM All doors and cased openings are trimmed with 2 1/2 casing. Vinyl coated wire shelving is provided in all closets. KITCHEN Kitchen countertops are granite. Cabinets feature wood doors and adjustable shelving. BATHROOM The bathrooms are to be constructed per the individual house plans and include low a dual flush toilet. The sink bowls are by Kohler or equivalent. All fiberglass units are by Lasco, Aker or equivalent. All faucets are Symmons, Kohler or equivalent. Home owners are to install their own mirror, shower curtain rod, towel racks, and TP holder. PAINTING All interior wood trim is primed and painted white in an acrylic semi-gloss. All interior walls to be painted in a color matched to Benjamin Moore's Linen White, in flat latex. All paint is to have low to no amounts of Volatile Organic Compounds(VOC's). FLOORING There is pre-finished oak hardwood in the foyer, dining room, kitchen, living room, mudroom and laundry area. The main stairs are oak. The bathrooms have tile from builder's selection. The upstairs remaining rooms are installed with recycled PET (recycled soda bottles) carpet. Seller retains the exclusive right to substitute equivalent or better products and/or materials from those indicated in the specifications without notice. Copyright©2013 Transformations,Inc. Specifications Laurel Street Zero Energy Homes As of June 4, 2013 WHAT IS A ZERO-ENERGY ATTAINABLE HOME? `Zero Net Energy' means the home produces as much energy as it uses, on an annual basis. A Zero-Energy Home is a home that produces as much as it consumes, based on computer modeling of the plans and specifications. FOUNDATION The foundation frost walls are 10"thick poured concrete. The garage floor is 4"thick poured concrete. The full foundation basement floor is 4"think poured concrete slab on top of 2" of rigid insulation. The basement foundation walls receive 3-3.5" of closed cell foam and a fire resistant paint. A bulkhead from the basement is included. EXTERIOR CONSTRUCTION Roofing material is 30 year architectural style shingles with 3' of ice and water shield. Exterior walls are 12"thick, constructed using advanced framing techniques with double studded 2x4's. The window wells are to be flared out with drywall returns and sills. The exterior sheathing uses a Zip wall system with the joints taped with the Zip material. A two car garage is provided. The siding is vinyl. The decks are pressure treated. The walk is in pavers. Two frost proof faucets are provided for. Builder supplied bushes and bark mulch are provided for in the front of the house. Town water and sewer are included. INTERIOR CONSTRUCTION Walls are smooth, ceilings are textured. Insulation in the above grade exterior walls is 12" of low density foam for a minimum R45.6 wall cavity. The attic floor is insulated with 18" of cellulose for an R-value of 63. WINDOWS AND DOORS Windows are vinyl R-5,Energy Star rating,tilt-in with screens. Exterior doors (including garage) are insulated vinyl panel doors. Interior doors are 6-panel Masonite painted white with "F"series Schlage brushed nickel passage sets. HEATING,VENTILATION AND AIR CONDITIONING The heating and air conditioning is a high efficiency mini-split air source heat pump system. Panasonic fans are installed in the bathrooms. Two of them will be set for 30 CFM continuous ventilation with a boost switch. APPLIANCES An electric washer and electric dryer hookup is provided for including the exterior vent. The allowance for the stove,microwave and dishwasher is$1,000. It is suggested that the homeowner buy an ultra efficient dishwasher,refrigerator, and washing machine. The electrical usage on these three appliances should not exceed 750 kilowatt hour per year. Copyright©2013 Transformations,Inc. C a• .o 00 0 M O a R . .- O N V 7 N a a ar N Q ++ n v o o M .o `A C v - 0.. � L C W o N M '- IC co a• .- fV 00 0 C C 4 'CO E o o.cu Q! rt V as N an vi W = a o" C v T R i • 0 on Q >O a) c N k 4 �41 O C - O V 0_ 4)17.. C X L _ a) O O L a O 'D L co E a 0 = U = J a to H U Q U a w O g o 3 v a) „_' Ts: O an•a ca N a O IO •� on C oOo r, C I > C a m •n' = Q • O C W >' 4-1 I r--- --1 a O as 8 a 0 c C as ft V `"° v a;w> = u `o • > •'m / �. O N `': V V 'a C on • N 0 a N `+ '' O O oTn 7 C 0 C • e- C O ▪ p N co O O 7 L �.+ W so ja a z = m w w ri o o c y m LN c = c=i� v=i O ,yi w V V N �( W -..1.7; �" • y r).. W 1.. co L a C L ci 12 a 4.• w a L a co vin u O C a c w w •0 3 p N a L"' — '• H ` OP J d V V T `wn `Wn 0 c@ p p ON v ce M E N a V1 F- fa O O i• yI a ' O O as -.......I ., rn •O w ce C M M co vI r j v;, all L aLi C a:+ N ,>: L W �. 7 N N On C C ..+ O IT a=+ to fo In •�� ' d O l� on On R as O U oc E co •� Z U.. u U a0.1 0 U C >,* w ro i ' a a z n u Zfi v N C = _ a n In o u E O W L~ (e O o 0/) -- OD O1! N >` O N U H L w u p' V _ = m N p V V y LI. , z 4• W' ^ E N c',-,; L 'c c C U O 0 .o .O ao O O so ro g O .ov ii v ° o ; a o . � .o a v, o L 45 WM N M W W v = c W = z Y o° °• o W C. to a) in N a •'- 3 174 V on u an an L L Ofl O a E E E g- g- c •o E •m a+► ro u c C C >, o '1" A v o v aO.+ a. a %I%I z In E MiO„ c v ti v .�.. Lan aI 3 11> Ce I. 0 `° H d aa)i '- 0 O L °) eo a `La m I�' o a) L L O i� C L L 4., a) +' 1— o U V1 0 1 4 •C co 2 C I '' c to s .1. o .. o C +'i �" V c •C p o a E w w c an C c cn 4. v J > m " i.t v a a CO cz •r'1 d ' Q Q 15 ,C a) •C O ' w o o '= OR a s 6 L.a. C9 1 a ea J MUNICIPAL SEWER/AVAILABILITY APPLICATION Northampton Streets Department • 125 Locust Street Northampton, MA 01060 587-1570 A Department of Public Works Trench Permit and Sewer Entry Permit shall be required prior to any construction or connection activity associated with this application. Location: 9 Laurel Street Inquiry Made By: Transformations Pam Kimball 978-790-9476 Date of Inquiry: 10/31/13 Reason for Request: Hook into City Sewer Municipal Sewer Main in Front of Location: Yes No Municipal Storm Drain Available: 5' deep Yes No Size of Sewer Main: 8 � Material: ( I.-A y 4-W C..r Age: ) (1013 Depth of Sewer Main: '-f Length of Sewer Main: O 1 Size of Service Connection: U A[l<No u N Type of Service Connection: Tie-in to Sanitary Main Tie-in to Sanitary Stub Comments: Note: If this availability is for new construction,this form must be hand delivered to Building Inspector. A corresponding"sewer entrance fee"shall be paid prior to making any connection to the municipal sewer system.Arrangements of such installation shall be made with the Northampton Streets Department with a minimum of 5 working days notification. All work shall conform to Northampton Streets Department specifications. John Hall Sewer Department cc: Ned Huntley, Director DPW Louis Hasbrouck, Building Commissioner ,r(� MUNICIPAL WATER AVAILABILITY APPLICATION ' Northampton Water Department 237 Prospect St. Northampton, MA 01060 587-1097 A Department of Public Works Trench Permit shall be required prior to any construction or connection activity associated with this application. Location: 9 Laurel Street Inquiry Made By: Transformations,Inc. Pam Kimball 978-790-9476 Date of Inquiry: 10/31/13 Number of Type of Single Family X Type of Private X Units: 1 Unit(s): Apart. Comm Ownership: Condo Multi-family Rental (Annlicant to fill out the above) Municipal Water Main in Existing service to Front of Location? Yes: X No: site? Yes: X No Size of Water Main: 8" Material: Ductile Iron Age: 2010 Approximate Static Street Flow Test Conducted: Yes: No: X Pressure: 90 psi If done attach results Size of Service Connection 1" Existing Stub Suggested Meter Size: 5/8" Comments: The Water Department cannot guarantee adequate water pressure during peak demand times at elevations above 320 feet. • A corresponding water entrance fee shall be paid prior to making any connection to the municipal water system. • Arrangements of such installation shall be made with the Northampton Water Department with a minimum of rking days notifica : . All wor shall co o No r4 ampton Water Department specifications. L David W. Sparks, Superintendent of Water Dept. Water Entry$200.00 Meter$100.00 Radio $100.00 cc: Ned Huntley,Director cc: Louis Hasbrouck,Building Commissioner U..J Note:If this availability is for a new construction,it must be hand delivered to the Building 4 Inspector. (SUBJECT TO ATTACHED CONDITIONS 1 &2) Permit No. D04-14 Conditions: Driveway Permit In lieu of plan approved by the City Engineer I agree to the following added conditions: 1. I will contact the Department of Public Works and have an inspector check and approve the graded gravel base prior to paving to insure compliance with slope and location; 2. I further agree that if in the inspections, any of the permit conditions are not met that I will at no expense to the City remove and replace the driveway as directed by the City Engineer. By: Petitioner Signature Name: Transformations/Pam Kimball Address: 8 Coppersmith Way Townsend, MA 01469-4412 Note: The Public Works Department recommends that you provide a plan showing the proposed driveway with grades and location in the future to avoid possible expense which you will incur by not getting approval of actual plans in advance. For Commercial and Industrial applicants, a plan showing the proposed driveway with grades, location and Planning Board permits are required. Cc: Building Inspector In Permit No. D 04-14 CITY OF NORTHAMPTON, MA DRIVEWAY PERMIT Date: 10/31/13 Check#: 18375 FEE: $250.00 THE BOARD OF PUBLIC WORKS Driveway must be staked and house& lot number posted The undersigned respectfully petitions your honorable body for: A new Curb Cut Permission to install a driveway at: 9 Laurel Street, Northampton Fifteen (15)foot maximum width from street line to property line. Gutter drainage not to be disturbed. All drainage shall be directed off the driveway surface to adjacent land and not on the existing roadway. The first one hundred(100) feet of the driveway surface shall be paved as soon as possible if the grade of the proposed driveway exceeds 3%at any point in the first one hundred(100) feet. Homeowners will be held responsible for any costs to the City of Northampton in the event of a washout of this driveway. City is not responsible for culverts installed under driveways in City layout. Code of Ordinances §350-8.8 providing standards for private, individual driveways as most recently amended,must be followed. By: Transformations / Pam Kimball Telephone: 978-790-9476 • attire: Proposed Location Inspection B 21 �IKA.4t�♦ ev C - • - 0/3 Gravel Base Grade Inspected By: Final Approval: THE BOARD OF PUBLIC WORKS voted that petition be granted. Edward S. Huntley,P.E. Director of Public Works Cc: Building Inspector u � � Transformations, Inc. Trade Subcontractor List As of October 7, 2013 CATEGORY COMPANY NAME CONTACT TELEPHONE# Cleaning (interior) David A. Hardy, Contractor, LLC David Hardy 413-527-2655 Drywall Rod's Drywall Rod Jalbert 413-977-3679 Drywall (alternate) Glidden Drywall Mark Glidden, Sr. 413-527-4340 Electrician Dan Whiteley, Inc. Dan Whiteley 413-527-1440 Excavator Truehart Paving & Construction Paul Truehart 413-527-9246 L Finish David A. Hardy, Contractor David Hardy 413-527-2655 Flooring First Prize Flooring Mike Labrecque 413-529-2662 Framing (labor) David A. Hardy, Contractor David Hardy 413-527-2655 Framing (labor) (Alternate) F. Roy & Sons Construction, Inc. Fred Roy 413-455-5929 Foundation Sub K&T Concrete Services Keith Tardy 413-626-9003 Garage Doors Raynor Door Sales Peter Paniczko 413-527-2447 HVAC Tin Man Heating &A/C John Hamilton 413-527-7722 Insulation Collins & Co. Keith Elmy 860-870-9803 Insulation (Alternate) First Prize Foam Insulators Mike Labrecque 413-529-2662 Landscaping Ray Haluch, Inc. Joanne Martins 413-583-6508 Landscaping (Alternate) Pioneer Landscapes, Inc. Brian Campedeli 413-527-0852 Painting David A. Hardy, Contractor David Hardy 413-527-2655 Plumbing Phillip's Plumbing & Heating, Inc. Phil Hurteau 413-527-0340 Chris Thomson & Roofing R.C.I. Roofing, LLP Mark Delise 413-527-4775 Siding Charles T. Laveck Home Improvements Chuck Laveck 413-246-9718 Siding (Alternate) All Star Insulation & Siding Co., Inc. Ed Losacano 413-527-0044 Stairs j Northeast Stair Co., LLC Bill Drzyzga 860-875-3358 Tile Keenan Tile Co. Tom Keenan 413-739-4124 CC: Joe Fydenkevez, Jr. R. Carter Scott _ — David Hardy 1 City of Northampton /2t Massachusetts <7.fr DEPARTMENT OF BUILDING INSPECTIONS t If en, " _. 212 Main Street to Municipal BuildingJ{ Northampton, MA 01060 sty`,l 71't� INSPECTOR Louis Hasbrouck Chuck Miller Building Commissioner Assistant Commissioner HOME OWNER EXEMPTION ACKNOWLEDGEMENT The State of Massachusetts allows the homeowner the right under 780CMR 108.3.4 to act as his/her construction supervisor. The state defines "Homeowner" as, " Person(s) who owns a parcel on which he/she resides or intends to be, a one or two family dwelling, attached or detached structures accessory to such use and/or farm structures. A person who constructs more than one home in a two- year period shall not be considered a home owner." The building department for the City of Northampton wants any person(s) who seek to use the home owner exemption, to act as their own construction supervisor, to be aware that by doing so you become responsible for compliance with state building codes and regulations. The inspection process requires that the building department be called to inspect work at various stages, which include foundation/footings (before backfill), sonotube holes (before pour), a rough building inspection (before work is concealed), insulation inspection (if required) and a final building inspection. The building department requires these inspections before the work is concealed, failure to secure these inspections can result in failure to obtain a certificate of occupancy until the work can be inspected. If the homeowner hires other trades to perform work (electrical, plumbing & gas) the homeowner will be responsible to make sure that the trades hired secure their proper permits in conjunction to the building permit issued, and that they get their required inspections. Failure of the individual trades to secure the permits and inspections as required can DELAY the project until such time as the proper permits and inspections are made understand the above. (Home owner/resident's signature requesting exemption) I will call to schedule all required building inspections necessary for the building permit issued to me. Date Address of work location The Commonwealth of Massachusetts ' Department of Industrial Accidents Office of Investigations gin= ' 600 Washington Street t vahp� 4' Boston, MA 02111 1,4,4,„,„,..0.7 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): 7 ' i s-{ry z j*S A, / C, Address: . Ste/A. i Z- 5-'°) City/State/Zip: 7/WfiSe4itk one #: 7 4 ° Are you an employer? Check the appropriate b�ob:= Type of project(required): LA'S 1.❑ I am a employer with 4• l am a general contractor and I employees (full and/or part-time).* have hired the sub-contractors 6. Ergr construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have 8. ❑ Demolition working for me in any capacity. employees and have workers' 9. r] Building addition [No workers' comp.insurance comp. insurance.$ required.] 5. ❑ We are:a corporation and its 10.❑ Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152, §1(4), and we have no employees. [No workers' 13.❑ Other comp. insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. tHo meowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: ' i if lid 15 4'Ct. ( 17f24j A—Policy#or Self-ins.Lic. #: &K-- U — O 32.6A/31 4 I Expiration Date: f l I i 4- Job Site Address: L �,,(U l StY?J2 //C 4 �tl ?6 ( a Attach a copy of the workers' compensation policy declaration page (showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of perjury that the information provided above is true and correct. Signature: .� Date: /�/` 0 Phone#: 0 715- 3i.7 -6542_ . Official use only. Do not write in this area, to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3. City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6. Other Contact Person: Phone#: SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: ( Not Applicable £ �� Name of License Holder: C�"� C', � ,C cr /?' ` /� _ `' License Num er Address Expiration Date d. ignature Telephone 9.Registered'.Home Improvement Contractor:' ;;,., Not Applicable £ /K4-'1i s vwr7`vi S Co pang Name Registration Number 3 Cpl wt.; c&-,TatAik ,� VlAA 0 (46 Address Expiration Date C1-73� Telephone � J��1 "6 31 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes.. .: £ No £ 11 . .Home Owrier Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors 0 Accessory Bldg. ❑ Demolition ❑ Ne Signs [O] Decks [[] Siding [0] Other[0] . 1 Brief De cripti•n of Propo :d , Work: s , ,, 3 . 4 .illl 1 LAW $ e✓4,e4 1cipme r l Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 'ea. If<Nevi/house end.oeadditioi to exlstinq`h`ous nq, ca npfete thelolio Ati11gI`c / : a. Use of building : One Family ✓ Two Family Other b. Number of rooms in each family unit: "'Number of Bathrooms c. Is there a garage attached? f j , d. Proposed Square footage of new construction. 9b2__ i ensionts `�' "- 11" Witt-leryL. e. Number of stories? f. Method of heating?2 141175 Silt t AI{S�(z irepleces or Woodstoves Number of each g. Energy Conservation Compliance. r• Masscheck Energy Compliance form attached? h. Type of construction -fi k-.bvi if i. Is construction within 100 ft. of wetlands? Yes 1/No. Is construction within 100 yr. floodplain Yes j. Depth of basement or cellar floor below finished grade 31 k. Will building conform to the Building and ning regulations? 7Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I , as Owner of the subject property hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application. Signature of Owner Date P14/1;d4 �j (evz �' , as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Si 4 /.1 Print Name / a--,le4-i e-„ ///2-4? nature of Owner/Agen Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by p 2 Building Department Lot Size 14 i 310 'j S ' Frontage 6): 52 4 Setbacks Front 11 .7re1 + Side L: R: L: JO R: IS ff.. Rear Building Height Bldg.Square Footage % ' v4 Open Space Footage % (Lot area minus bldg&paved 65 parking) #of Parking Spaces Z Fill: (volume&Location) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO O DON'T KNOW YES 0 IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO O DON'T KNOW 0 YES O IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO C DONT KNOW O YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained O Obtained O , Date Issued: C. Do any signs exist on the property? YES a NO O IF YES, describe size, type and location: ta,e,6./1-14--y Sij kS D. Are there any proposed changes to or additions of signs intended for the property? YES O NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavation,or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YEE O NO IF YES,then a Northampton Storm Water Management Permit from the DPW is required. Department use only I F. City of Northampton Status of P Building Department Curb Cu : - : •: mit 212 Main Street Sewer/S-, •l#=stability j,✓ '+~ 'VuV `6 2Li Room 100 Water/Well Availability N rthampton, MA 01060 "two Sets of Structural Plans ti�`r Lini-,,..__.1_, p ;_.....�.., honei41 -587-1240 Fax 413-587-1272 Plot/Site Plans -- _w_ bons Other Specify APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office r it awe ( ,)r)vL i- Map gip"J Lot /1- `5 Unit Zone Overlay District// k 1uj t// t 7, /11 Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2,1 Owner of Record: /yi�t15tc—ei n(-1i(7i,1S _71/- !C `�' ( iSiiUi ti.. (4,4ic. 1 /c,,i a Art Name(Print) Current M il9 ing Address: 6.2/4 6-1 C/TO - 34 7 0 42 Telephone Signature % °c f / eI∎ ~ 2.2 Authorized Agent: Name(Print) Current Mailing Address: Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building .2-2.--2-j II C1 ® (a)Building Permit Fee 2. Electrical 6- (b)Estimated Total Cost of 1 t Construction from (6) 3. Plumbing II, 560 Building Permit Fee 4. Mechanical(HVAC) (/;3` r s-co 5. Fire Protection _ 6. Total=(1 +2+3+4+5) 2li1i 1(1Q Check Number / (F' 1s il))j) , 'lc �I This Section For Official Use Only uildin, Permit Number: Date Issued: Signature: Building Commissioner/Inspector of Buildings Date File#BP-2014-0583 0[e___t4N APPLICANT/CONTACT PERSON TRANSFORMATIONS INC AQA ADDRESS/PHONE 8 COPPERSMITH WAY TOWNSEND (978)597-0542 pp 1 ' PROPERTY LOCATION 3 LAUREL ST MAP 38A PARCEL 145 001 ZONE THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out �'1 ( Fee Paid Typeof Construction: CONSTRUCT 2 STORY SFH W/ATT GARAGE/PORCH New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 055181 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFQ MATION PRESENTED: Approved Additional permits required(see below) PLANNING BOAIUI)PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission _ Permit DPW Storm Water Management Demoliti Delay /44**--.°°°°° Signature of Building Official Date Note:Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of Planning&Development for more information. 3 LAUREL ST BP-2014-0583 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 38A- 145 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category:New Single Family House BUILDING PERMIT Permit# BP-2014-0583 Project# JS-2014-000972 Est. Cost: $249990.00 Fee:$1186.40 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: TRANSFORMATIONS INC 055181 Lot Size(sq. ft.): 14331.24 Owner: TRANSFORMATIONS INC Zoning: Applicant: TRANSFORMATIONS INC AT: 3 LAUREL ST Applicant Address: Phone: Insurance: 8 COPPERSMITH WAY (978) 597-0542 WC TOWNSENDMA01469 ISSUED ON:11/19/2013 0:00:00 TO PERFORM THE FOLLOWING WORK:CONSTRUCT 2 STORY SFH W/ATT GARAGE/PORCH POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 11/19/2013 0:00:00 $1186.40 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner