Loading...
41-016 (15) Ground Floor I iii Medial ibrary it I 1 Stair Up Unfinished Space l I Hall j 1 i i l I ill i Bedroom 2 i Bath Fred's Office ;l I . l f L. Job#: M.J. Moran, Inc. Scale: 1 : 140 Performed for: Page 1 Fierst Residence 4 South Main St. Right-Suite®Universal Haydenville,MA 01039 7.1.22 RSU03081 Phone: 1-413-268-7251 Fax: 1-413-268-9375 2013-Jan-05 20:00:36 ...ightsoft HVAC\Fierst Revised.rup rrov anmimoraninc.com First Floor Mudroom Laundry Room Master Bath ,faster Closet Master Bedroon Garage est Bath Entry Gallery Stair DN ,‘,,, .............p,, L 1 i 1 t Kitchen Dining/Living II i r>>r Job#: M.J. Moran, inc. Scale: 1 : 140 Performed for: Page 2 Fierst Residence 4 South Main St. Right-Suite®Universal Haydenville,MA 01039 7.1.22 RSU03081 Phone: 1-413-268-7251 Fax: 1-413-268-9375 2013-Jan-05 20:00:36 ...ightsoft HVACTierst Revised.rup rrovamimoraninc.com -4, Load Short Form Job: at4+ *iir+ir> ,. Date: Jan 05,2013 to, Master By: M.J. Moran, Inc. 4 South Main St.,Haydenville,MA 01039 Phone:1-413-268-7251 Fax:1-413-268-9375 Email:rroy @mjmoraninc.com Project information For: Fierst Residence Design Information Htg Clg Infiltration Outside db(°F) -2 85 Method Simplified Inside db(°F) 70 75 Construction quality Semi-tight Design TD(°F) 72 10 Fireplaces 0 Daily range - M Inside humidity(%) 50 50 Moisture difference(grub) 52 28 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a GAMA ID n/a Coil n/a ARI ref no. n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh r:\ ' Actual air flow 0 cfm Actual air flow 0 cfm �' Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) 1 Master Closet 98 627 194 18 1 '9 s'. Master Bath 168 1433 515 41 24 Master Bedroon 238 2873 1953 83 r' 89 -,' Master 504 4933 2662 142 122 Other equip loads 0 0 Equip. @ 0.90 RSM 2395 Latent cooling 569 TOTALS 1 504 I 4933 I 2965 I 142 I 122 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. -V4i1- wrightsoft Rig ht-Suite®U niversal 7.1.22 R SU03081 2013-Jan-0519:59:28 ..Settings\bobr\My Documents\Wrightsoft HVAC\Fierst Revised.rup Calc=MJ8 Orientation=N Page 4 r • "rtt\ Load Short Form Job: rith rw�MYr' C. Date: Jan 05,2013 Ground By: M.J. Moran, Inc. 4 South Main St.,Haydenville,MA 01039 Phone:1-413-268-7251 Fax:1-413-268-9375 Email:rroy©mjmoraninc.com Project Information For: Fierst Residence Design Information Htg Clg Infiltration Outside db(°F) -2 85 Method Simplified Inside db(°F) 70 75 Construction quality Semi-tight Design TD (°F) 72 10 Fireplaces 0 Daily range - M Inside humidity(%) 50 50 Moisture difference(grub) 52 28 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a GAMA ID n/a Coil n/a ARI ref no. n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H20 tit:: £ Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Media/Library 294 2872 1134 83 52 '1 Stair Up 52 823 609 24 la, Fred's Office 186 3567 3773 103 )-1 4 172 ` Hall 114 1334 684 38 1 31 i Bedroom 2 192 3937 2993 113 i',' 137 P Bath 128 1671 2302 48 .,7 5105 , ° Ground 966 14205 11495 409 525 ,-. 43 Other equip loads 0 0 Equip. @ 0.90 RSM 10346 Latent cooling 262 TOTALS l 966 I 14205 I 10608 I 409 I 525 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. ^•.• - ,i- vvrightsoft Right-Suite®Universal 7.1.22 RSU03081 2013-Jan-0519:59:28 CC.A ...Settings\bobr\My Documents\Wrightsoft HVAC\Fierst Revised.rup Cale=MJ8 Orientation=N Page 3 . A Load Short Form Job: midd iwr First Floor Date: Jan 05,2013 By: M.J. Moran, Inc. 4 South Main St.,Haydenville,MA 01039 Phone:1-413-268-7251 Fax:1-413-268-9375 Email:rroy @mjmoraninc.com Project Information For: Fierst Residence Design Information Htg Cig Infiltration Outside db(°F) -2 85 Method Simplified Inside db(°F) 70 75 Construction quality Semi-tight Design TD(°F) 72 10 Fireplaces 0 Daily range - M Inside humidity(%) 50 50 Moisture difference(gr/lb) 52 28 i HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a GAMA ID n/a Coil n/a ARI ref no. n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 4. ROOM NAME Area Htg load Cig load Htg AVF Clg AVF (f 2) (Btuh) (Btuh) (cfm) (cfm) if Dining/Living 580 7971 10085 230 461 !4-r-:--:1, Kitchen 280 4028 3807 116 174 Laundry Room 85 1324 839 38 38 Guest Bath 25 70 27 2 1 Mudroom 70 1396 288 40 ft Entry 110 3117 2056 90 94 '7+' Gallery 80 225 87 6 * First Floor 1230 18130 17189 522 7V5 Other equip loads 0 0 Equip. @ 0.90 RSM 15470 Latent cooling 1635 ° TOTALS t 1230 I 18130 I 17106 I 522 I 785 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. - - wrightsoft Right-Suite®Universal 7.1.22 RSU03081 2013-Jan-0519:59:28 ACLA .Settings\bobr\My Documents\Wrightsoft HVAC\Fierst Revised.rup Calc=MJ8 Orientation=N Page 2 A Add wi Project Summary Date: Jan 05,2013 Entire House By: M.J. Moran, Inc. 4 South Main St.,Haydenville,MA 01039 Phone:1-413-268-7251 Fax:1-413-268-9375 Email:rroy @mjmoraninc.com Project Information For: Fierst Residence Notes: Desi s n Information Weather: Greenfield, MA, US Winter Design Conditions Summer Design Conditions Outside db -2 °F Outside db 85 °F Inside db 70 °F Inside db 75 °F Design TD 72 °F Design TD 10 °F Daily range M Relative humidity 50 % Moisture difference 28 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 37267 Btuh Structure 23200 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(113 cfm) 3091 Btuh Central vent(113 cfm) 429 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 40358 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 21266 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2467 Btuh Ducts 0 Btuh Heating Cooling Central vent(113 cfm) 741 Btuh Area(ft2) 2700 2700 Equipment latent load 3208 Btuh Volume(ft3) 25365 25365 Air changes/hour 0.22 0.11 Equipment total load 24474 Btuh Equiv.AVF(cfm) 93 47 Req. total capacity at 0.70 SHR 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond GAMA ID Coil ARI ref no. Efficiency 80 AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 1073 cfm Actual air flow 1073 cfm Air flow factor 0.029 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. , -i4*. orris,I rsnft Right-Suite®Universal 7.1.22 RSU03081 2013-Jan-0519:59:28 ACCA ...Settings\bobr\My Documents\Wrightsoft HVAC\Fierst Revised.rup Cabo=MJ8 Orientation=N Page 1 INSURANCE COVERAGE: I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L.Ch.112 Yes Igl No❑ If you have checked Yes,indicate the type of coverage by checking the appropriate box below: A liability insurance policy ® Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER:I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. Check One Only Owner ❑ Agent ❑ Signature of Owner or Owner's Agent By checking this boxD,I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation:YES NO Progrecc Tncnertinnc Date Comments Final Incppetinn 1�atP Comments Type of License: By Master Title ❑Master Restricted CityfTown v ❑Journeyperson Signature of Licensee Permit# ❑Journeyperson-Restricted �� License Number: Fee$ ❑ Check ats'.':a<', .. 5inv!but Inspector Signature of Permit Approval V ii+r.`i Commonwealth of Massachusetts U 11 U61 — l 2013 j' City Of Northampton it t3-376 Electric, Plumbing&Gas Inspections ../ �c2O No L•m.ton, M ;,�,; ._ Sheet Metal Permit • Permit# 5 �,� ' Estimated Job Cost: $ `ft 30/Qc r-, , , r j 0g Permit Fee: $ ,�5,@a Plans Submitted: YES NO ✓ Plans Reviewed: YES NO Business License# 11 a Applicant License# c)10 1 Business Information: Property Owner/Job Location Information: Name: ('\.S_ (n0( ( , ,r1C. Name: -ev ..c\ec3 Street: 4 South ma■ri S tat t Street: 1016'2) we_5' .c,,,Nrrni- RA City/Town: 11&fi en U1III. City/Town: MOCft-krw-m,-, Telephone: Lit a- all?`tS- ):S i Telephone: Photo I.D.required/Copy of Photo I.D. attached: YES NO +; Staff Initial J-1 .I-1 inrestricted license J-2/M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less Residential: 1-2 family V Multi-family Condo/Townhouses Other Commercial: Office Retail Industrial Educational Institutional Other Square Footage: under 10,000 sq. ft. v7 over 10,000 sq. ft. Number of Stories: Sheet metal work to be completed: New Work: Renovation: HVAC V/ Metal Watershed Roofing Kitchen Exhaust System Metal Chimney/Vents Air Balancing Provide detailed ydeescription of work to be done: J� i'1.. /,-c C t 3 IC 46.r 'f /Cry urti r v i r... L) CT- 5 ySr"S Fees with Building Permit:$25.00 Residential,$50.00 Commercial.Fees for jobs without a Building Permit$6.00 per$1000 Minimum fees for jobs without Building Permit$50.00 Residential,$100.00 Commercial File#SM-2014-0020 APPLICANT/CONTACT PERSON M J MORAN ADDRESS/PHONE P O BOX 278 (413)268-7251 PROPERTY LOCATION 1253 WESTHAMPTON RD MAP 41 PARCEL 016 001 ZONE THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid JO Building Permit Filled out I' Fee Paid Typeof Construction: INSTALL HADLER/ERV UNIT W/DUCT SYSTEMS New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 267 3 sets of Plans/Plot Plan THE FOLL NG ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFO ATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER: § Intermediate Project: Site Plan AND/OR Special Permit with Site Plan Major Project: Site Plan AND/OR Special Permit with Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee • • Street Co • ssion Permit DPW Storm Water Management Sig dir - • Bu .m_-G facial Date Note:Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact the Office of Planning&Development for more information. 1253 WESTHAMPTON RD SM-2014-0020 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON LGIS 18059 'Map: 41 Block 016 � SHEETMETAL PERMIT ,Lot: 001 , „Permit: SHEETMETAL �ss _,L N A�`9y4 Category: jSHEETMETAL Permit# SM-2014-0020 PERMISSION IS HEREBY GRANTED TO: Project# JS-2013-002010 � - - - -Contractor: License: Expires: Est. Cost: $30,000.00 ---__-_- d:— -- M J MORAN Sheetmetal-267 Fee Charged:$25.00 05/01/2014 Balance Due:$.00 Owner: FIERST FREDERICK U&EVA C #of Fixtures: Applicant: M J MORAN 1DigSafe# AT: 1253 WESTHAMPTON RD UseGroup ConstClass ISSUED ON: 15-Oct-2013 AMENDED ON: EXPIRES ON: TO PERFORM THE FOLLOWING WORK: INSTALL HANDLER/ERV UNIT W/DUCT SYSTEMS THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fee Type: Receipt No: Date Paid: Check No: Amount: Sheetmetal REC-2014-001605 08-Oct-13 108409 $25.00 212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:lhasbrouck @northamptonma.gov GeoTMS®2013 Des Lauriers Municipal Solutions,Inc.