Loading...
32C-003 (3) Gensler Mr.Louis Hasbrouck Building Commissioner 09/25/2013 Page 2 Required Exit Access Width: Door Width (1005.1.2) 41 OCC @.15"/OCC=6.15"Total Width Required Provided 2 doors @ 32"Clear=64" There is no MEP Design Engineer.The GC shall provide all the work related to engineering to include but not limited to:Structural,Civil,Mechanical,Electrical,and Fire protection&life Safety.The GC shall provide design drawings,permits and installation on a Design Build Basis. If you have specific questions regarding this information or the plans in general please contact me directly at 617-619-5710 or Delia Gott at 617-619-5731. We look forward to working with you and the City on this project. Sincerely, CHtTFej �w� t, Ftsg, Kenneth I.Fisher,AIA �; 44 F' Principal z013 '9 Enclosure t cc: Delia Gott 'WEA1"M - One Beacon Street Tel 617.619,5700 Third Floor Fax 617.619.5701 Boston MA 02108 USA Gensler 09/25/2013 Mr.Louis Hasbrouck Building Commissioner 210 Main Street Northampton,MA 01060 Subject: Bank of America Minor Renovation CODECOMPLIANCE 144 Main Street Northampton,MA Project Number:11.6561.010 Dear Mr.Hasbrouck, This letter is to confirm that the plans for BOA 144 Main Street,Northampton,MA have been prepared under my supervision and are in compliance with the following codes: Building Code: MA State Building Code,8th Edition(2009 IBC)&(2009 IEBC) with 2010 MA State Amendments Use Group: Business B Fire Protection: Fully Sprinklered Occupancy Calculation: Ground Floor Area:4,052 S.F. (1004.1.1) Total Occupant Load:41 Required Exits: 41 OCC.<50:I Exit Required (1015.1) (2 Exits Provided) Exit Separation: 127'Max Diagonal /2:63.5'min.exit separation required (1015.2.1) (101' Exit Separation Provided) Exit Travel Distance: Fully Sprinklered 300'Max. (1016.1) (117'Provided) Common Path of Travel: Fully Sprinklered 100'Max. (1014.3) (63'Provided) Dead End Corridors: Fully Sprinklered 50'Max. (1018.4) (21'Provided) 9/26/13 City of Northampton Mail-Re:FW:Northampton permitting -+'s; A Re: FW: Northampton permitting Louis Hasbrouck <Hasbrouck @northamptonma.gov> Thu, Sep 26, 2013 at 9:20 AM To: Javier Campos <jcampos @adamsruxton.com> Javier, I have signed the permit and it is ready to pick up. Out office hours are 8:30-4:30. I've approved the permit under the conditions allowed by IEBC section 101.5, exception: 101.5 Compliance methods. The repair, alteration, change of occupancy, addition or relocation of all existing buildings shall comply with one of the methods listed in Sections 101.5.1 through 101.5.3 as selected by the applicant. Application of a method shall be the sole basis for assessing the compliance of work performed under a single permit unless otherwise , 2,-) approved by the code official. Sections 101.5.1 through 101.5.3 i N F((. shall not be applied in combination with each other. Where this code requires consideration of the seismic-force-resisting system of an existing building subject to repair, alteration, change of occupancy, addition or relocation of existing buildings, the seismic evaluation and design shall be based on Section 101.5.4 regardless of which compliance method is used. Exception: Subject to the approval of the code official, alterations complying with the laws in existence at the time the building or the affected portion of the buildingwas built shall be considered in compliance with the provisions of this code unless the building is undergoing more than a limited structural alteration as defined in Section 807.4.3. New structural members added as part of the alteration shall complywith the International Building Code. Alterations of existing buildings in flood hazard areas shall complywith Section 601.3. / Louis Hasbrouck / Building Commissioner r/ City of Northampton / Town of Williamsburg f, (413) 587-1240 office (413) 587-1272 fax / ,i On Thu, Sep 26, 2013 at 7:12 AM, Javier Campos <jcampos @adamsruxton.com> wrote: Louis, Attached is the code compliance letter you requested. Please let me know if this will suffice or you need the original. If so, we should have it later today and I can drop it off no later than tomorrow. https://mail.g oog le.com/mai I/u/0/?ui=2&ilrec5f19a57e&view pt&search=sent&th=1415a6d438174b3a 1/10 . / » 2 . « �/� /\ " � N4 /� \ \� ) . ~• A¥ \ \ NORTHAMPTON, MA CONSTRUCTION CONTROL PROJECT NUMBER: 11.6561.010 PROJECT TITLE: Minor Renovation PROJECT LOCATION: Northampton, MA ADDRESS OF BUILDING: 144 Main Street NATURE OF PROJECT: Minor Renovation In accordance with 780 CMR, Section 107.0, 107.3.4 "Design Professional in Responsible Charge" and 107.6 "Construction Control" of the 8th edition of the Massachusetts State Building Code, I, Kenneth I. Fisher, AIA Registration No. 10373, being a registered professional architect hereby represent that I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning: Entire Project Architectural X Structural Mechanical Fire Protection _ Electrical Other (Specify) For the above named project and that, to the best of my knowledge, such plans, computations and specifications meet the applicable provisions of 780 CMR (8 edition) the Massachusetts state building code, all acceptable engineering practices and all applicable laws and ordinances for the proposed use and occupancy. I further represent that I, or qualified professionals under my supervision, shall perform the necessary professional services and be present on the construction site on a regular and periodic basis to determine that the work is proceeding in accordance with the documents approved for the building permit and shall be responsible for the following as specified in section 780 CMR Section 107.6.2.2 (8th edition): 1. Review, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with requirements of the construction documents. 2. Perform the duties for registered design professionals in Chapter 17(Structural Tests and Special Inspections) 3. Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work is being performed in a manner consistent with the construction documents and this code. I shall submit periodically, a progress report together with pertinent comments to the building inspector. Upon completion of the work, I shall submit a final report as to the satisfac e r completion and readiness of the project r occupancy. s.0ED 00./1 H I. oe./ SIGNATURE x441 10373 In COMPANY NAME Gensler COMPANY ADDRESS One Beacon St, MA 02108 .y�,_ ?c4IN OF SUBSCRIB•D AND SWORN TO BEFORE ME THIS DAY OF „�� . , ∎i /11.9: MY COMMISSION EXPIRES , _ .•..0 �p �9F ARY P : ' 3;. :•�;+ ‘,r r�� t • t4I Of 1101.k.. The Commonwealth of Massachusetts n Department of Industrial Accidents ? l r"'" 1, Office of Investigations Shill 1 Congress Street, Suite 100 f _'°;��= ` Boston, MA 02114-2017 "��'1' '� www mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): OP1 V 4 )(TON CO� I f�c 1 (C) ( ( t Address: 600 C)IQ(Oi`( ST City/State/Zip: W. . r g1 k.( (-LW, M n Phone #: - 1 --) - 1 - 2 t Are you an employer? Check theapropriate box: Type of project(required): 1.'am a employer with 2 4. ❑ I am a general contractor and I employees (full and/or part-time).* have hired the sub-contractors 6. [' New construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. elemodeling ship and have no employees These sub-contractors have 8. ❑ Demolition working for me in any capacity. employees and have workers' g Y 9. ❑ Building addition [No workers' comp. insurance comp. insurance.* required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.0 Roof repairs insurance required.] t c. 152, §1(4),and we have no employees. [No workers' 13.0 Other comp. insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. $Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. ,� ,�,.-^, Insurance Company Name: E-E-r�--LE55 j___� ) A C�->' LV " _ Policy#or Self-ins. Lic. #: Vi C. 1 58 Z 4 2-- Expiration Date: l2 3 /^ /3 Job Site Address: ��- M'f'`\k" s'l City/State/Zip: No ell--11-\OT()J t ►• A Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date"''I a) Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do herebyv--cefiii7Tder the pains an a alties.of perjury that the information provided above is true and correct. Signatttce: ' �� �' '17. --2 Date: 2f t3 Phone#: 4 1 ' - 131- 2_1 _,q Ti Official use only. Do not write in this area, to be completed by city or town official. City or Town: Permit/License # Issuing Authority(circle one): 1.Board of Health 2.Building Department 3. City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: CBRE CB RICHARD ELLIS September 23, 2013 Louis Hasbrouck Building Commissioner City of Northampton Puchalski Municipal Building 212 Main Street Northampton, MA 01060 Re.: Bank of America Retail Banking Center 144 Main Street Northampton, MA 01060 Dear Mr. Hasbrouck, CBRE is retained by Bank of America as their property and project management company throughout New England. CBRE has contracted Adams & Ruxton Construction Company out of West Springfield, MA to complete a project at the above referenced Bank of America Retail Banking Center. The scope of work is detailed in drawings developed by Genlser Associates out of Boston, MA. It would be appreciated that a permit be issued to Adams & Ruxton for the above work on behalf of CBRE and the Bank of America. Thank you for your attention and if you should have any questions please feel free to contact me at any time. Very Truly Yours, CB Richard Ellis _ - ... Ed Griffin i Project Manager CBRE (Bank of America Retail) 25 Ladyslipper Dr Shrewsbury, Ma. 508-842-0904 Versionl.7 Commercial Building Permit May 15,2000 SECTION 10-STRUCTURAL PEER REVIEW(780 CMR 110.11) Independent Structural Engineering Structural Peer Review Required Yes 0 No SECTION 11 -OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT as Owner of the subject property hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application. i I\C4 LE-71E Signature of Owner Date I, _JAN \ (PVt 1G5 (A2\v( 4 (i)TC) I CO A/ l 1 (1 CT 1 d ivI) ,as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. .JAv t E . G M POS Print _ �-Z4--- 1 Signatur- •`erner/grent Date SECTION 12-CONSTRUCTION SERVICES 10.1 Licensed Construction Supervisor� t Not t Applicable ❑ Name of License Holder: i ,�)I i tM� tt V J�- t CS — \./ License Number 600 r elw ST v j _S k t'J&f 10_1 1'1 A d 11J e - - zo 1 Address Expiration Date 6k1-131 —213E5 gnature Telephone (y SECTION 13-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes No O Versionl.7 Commercial Building Permit May 15,2000 SECTION 9-PROFESSIONAL DESIGN AND CONSTRUCTION SERVICES-FOR BUILDINGS AND STRUCTURES SUBJECT TO CONSTRUCTION CONTROL PURSUANT TO 780 CMR 116(CONTAINING MORE THAN 35,000 C.F.OF ENCLOSED SPACE) 9.1 Registered Architect: Y E 1`- K I --( r..I 5 HEk. ( ULEf li teCh/Tt(7s Not Applicae El Name(Registrant): "' 02. 168 Registration Number OO l 1 c r! T , c-s7 LC +4 A Address CE 7 04 0 p A w itS cf l 12A t / 617'E 7 1 Expiration Date Signature Telephone 9.2 Registered Professional Engineer(s): Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date 9.3 General Contractor 1\OA15 P-U 0014 CO ti T UC11'0r.( Cu Not Applicable ❑ Company Name: N D�2 1/ ii O OC i-I E t e Responsible In Charge of Construction (L0C� /CM 5TVC) ScYl `E1-k) M OIO 1 Address CC1-:`r 4 2135 S?�gnature Telephone Versionl Commercial Building Permit May 15,2000 8. NORTHAMPTON ZONING / - \ C Z Vic K Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage Open Space Footage (Lot area minus bldg&paved parking) #of Parking Spaces Fill: (volume&Location) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO 0 DONT KNOW O YES 0 IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DON'T KNOW 0 YES IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO O DON'T KNOW Q YES Q IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained i© Obtained O Date Issued: C. Do any signs exist on the property? YES O NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES © NO Q IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavation,or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES O NO Q IF YES,then a Northampton Storm Water Management Permit from the DPW is required. Versionl.7 Commercial Building Permit May 15,2000 SECTION 4-CONSTRUCTION SERVICES FOR PROJECTS LESS THAN 35,000 CUBIC FEET OF ENCLOSED SPACE Interior Alterations Existing Wall Signs ❑ Demolition El Repairs El Additions El Accessory Building❑ Exterior Alteration ❑ Existing Ground Sign❑ New Signs❑ Roofing El Change of Use❑ Other❑ Brief Description Enter a brief description here. Q-EPL-t\«: (PAS PET-T 10 E«�F I Gu cE Of Proposed Work: —7--€1.-W .. L.I t-%E `-f U C e, A`E A tom- CU £1 A- fTi L6 A et: • SECTION 5-USE GROUP AND CONSTRUCTION TYPE USE GROUP(Check as applicable) CONSTRUCTION TYPE A Assembly E.1 A-1 ❑ A-2 ❑ A-3 ❑ 1A I ❑ A-4 El A-5 El 1B ❑ B Business Ir. 2A ❑ E Educational ❑ 2B I ❑ F Factory ❑ F-1 El F-2 ❑ 2C ❑ H High Hazard ❑ 3A ❑ I Institutional ❑ 1-1 ❑ 1-2 El 1-3 ❑ 3B ❑ M Mercantile ❑ I 4 ❑ R Residential ❑ R-1 ❑ R-2 ❑ R-3 ❑ 5A ❑ S Storage ❑ S-1 ❑ S-2 ❑ 5B I ❑ U Utility ❑ Specify: [ M Mixed Use ❑ Specify: S Special Use ❑ Specify: COMPLETE THIS SECTION IF EXISTING BUILDING UNDERGOING RENOVATIONS,ADDITIONS AND/OR CHANGE IN USE Existing Use Group: 9U5l 55 &'P-OU f Proposed Use Group: 1A Existing Hazard Index 780 CMR 34): Proposed Hazard Index 780 CMR 34): SECTION 6 BUILDING HEIGHT AND AREA BUILDING AREA EXISTING PROPOSED NEW CONSTRUCTION OFFICE USE ONLY S'-- Ali L� J 9�A 11 k► 5 Floor Area per Floor(sf) �� 1st 1St 2nd 2nd 3rd 3rd 4th 4th Total Area(sf) Total Proposed New Construction(sf) Total Height(ft) Total Height ft 7.Water Supply(M.G.L.c.40,§54) 7.1 Flood Zone Information: 7.3 Sewage gisposal System: Public [ Private ❑ Zone Outside Flood Zone❑ Municipal [IZI On site disposal system E C. (( \\, 7 Versionl.7 Commercial Building Permit May 15,2000 Department use only LE_P_ 2 4 201 1; City of Northampton Status of Permit. _ t Budding Department Curb Cut/Driveway Permit 212 Main Street Sewer/Septic Availability Eleptnc F�umr r�r -ections Room 100 Water/Well Availability Northampton, MA 01060 Two Sets of Structural Plans phone 413-587-1240 Fax 413-587-1272 Plot/Site Plans Other Specify APPLICATION TO CONSTRUCT, REPAIR, RENOVATE,CHANGE THE USE OR OCCUPANCY OF,OR DEMOLISH ANY BUILDING OTHER THAN A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: . This section to be completed by office• A M Po, `9T V t f Map J .„ Lot Unit ()/ i HA 4()TOO,OO, N4" ` 0 1060 Zone Overlay District -Bark/It Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: 25 1-A0)(51- - ( 1E (E0 i4 t�� 5H Ew 3,15. iRy(, NIA OFA Name(Print) Current Mailing Address: t1 fC H C_�7120I&L2 - Signature Telephone 2.2 Authorized Agent: ,�!1 'DA( . ) EE,J ,),6 1, G> \1c vu, S i nJ t=(e1' t\./1 {� j Name(Print) cf. VA-' t4 (CV'f ST f''c.LT(O�() Current Mailing Address: 13--13-4-2-A Signatures--•-�,,,. _ Telephone « � SECTION • -ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building 30 b (a)Building Permit Fee ) � 2. Electrical (b)Estimated Total Cost of 3 s D Construction from(6) 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) 5. Fire Protection 0' �� �� � lr b 6. Total= (1 +2+3+4+5) S 3 S O 4t, Check Number 9 This Section For Official Use Only '71111"' Building Permit Number Date Issued Signature: Building Commissioner/Inspector of Buildings Date ,, c Hoat Foe-- t tAP - M 6L5 CARE REARIV 144 MAIN ST BP-2014-0365 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 32C-003 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Pennit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: renovation BUILDING PERMIT Permit# BP-2014-0365 Project# JS-2014-000613 Est. Cost: $33500.00 Fee: $201.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: ADAMS & RUXTON CONSTRUCTION CO., INC. 071951 Lot Size(sq. ft.): 4835.16 Owner: CBRE Zoning: CB(100)/ Applicant: ADAMS & RUXTON CONSTRUCTION CO., INC. AT: 144 MAIN ST Applicant Address: Phone: Insurance: 600 UNION ST (617) 734-2138 () Workers Compensation WEST SPRINGFIELDMA01089 ISSUED ON:9/24/2013 0:00:00 TO PERFORM THE FOLLOWING WORK:REPLACE CARPET & RECONFIGURE TELLER LINE TO CREATE NEW WAITING AREA POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 9/24/2013 0:00:00 $201.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner