Loading...
31C-028 (3) 4 Load Short Form Job: wrightsoft Date: SECOND FLOOR By: RICHIE RICHIE'S AIR CONDITIONING & HEATING 81 Industrial Lane,Agawam,Ma Project Information For: SUE&JAY BREINES,THE PECOY COMPANY LOT A18 VILLAGE HILL, NORTHAMPTON, MA Design Information Htg Clg Infiltration Outside db(°F) 0 87 Method Simplified Inside db(°F) 70 75 Construction quality Tight Design TD(°F) 70 12 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/lb) 29 24 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (It2) (Btuh) (Btuh) (cfm) (cfm) WALK-IN 169 2785 471 64 22 BED/BATH 1 280 5510 3768 126 172 BED 2 240 5295 3224 121 148 BED 3 280 6646 3848 152 176 SECOND FLOOR 969 20236 11312 461 518 Other equip loads 0 0 Equip. @ 0.92 RSM 10407 Latent cooling 178 TOTALS I 969 I 20236 I 10585 I 461 I 518 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Sep-12 06:48:03 wrightsoft Right-Suite®Universal 2012 12.0.11 RSU17313 Page 3 -'-+M1 ...Documents\Wrightsoft HVAC\RICHIE'S PECOY A18 VILLAGE HILL.rup Calc=MJ8 Front Door faces: 4 Load Short Form Job: wrightsoft Date: FIRST FLOOR By: RICHIE RICHIE'S AIR CONDITIONING & HEATING 81 Industrial Lane,Agawam,Ma Project Information For: SUE&JAY BREINES,THE PECOY COMPANY LOT A18 VILLAGE HILL, NORTHAMPTON, MA Design Information Htg Clg Infiltration Outside db (°F) 0 87 Method Simplified Inside db(°F) 70 75 Construction quality Tight Design TD(°F) 70 12 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/Ib) 29 24 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (W) (Btuh) (Btuh) (cfm) (cfm) MUSIC ROOM 260 7778 6132 177 281 FAMILY/DIN/KITCHN 1000 20207 12831 461 587 FIRST FLOOR 1260 27985 18963 638 868 Other equip loads 0 0 Equip. @ 0.92 RSM 17446 Latent cooling 609 TOTALS I 1260 I 27985 I 18055 I 638 I 868 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Sep-12 06:48:03 t -4 wrightsoft Right-Suite®Universal 2012 12.0.11 RSU17313 Page 2 i ...Documents\Wrightsoft HVAC\RICHIE'S PECOY A18 VILLAGE HILL.rup Calc=MJ8 Front Door faces: <;. /C—CD'cr 4 Load Short Form Job: wrightsoft Date: Entire House By: RICHIE RICHIE'S AIR CONDITIONING & HEATING 81 Industrial Lane,Agawam,Ma Project Information For: SUE&JAY BREINES,THE PECOY COMPANY LOT VILLAGE HILL, NORTHAMPTON, MA 1 6 mv sT.. Design Information Htg Clg Infiltration Outside db (°F) 0 87 Method Simplified Inside db(°F) 70 75 Construction quality Tight Design TD(°F) 70 12 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/lb) 29 24 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80 AFUE Efficiency 0 SEER Heating input 0 MBtuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 1100 cfm Actual air flow 1100 cfm Air flow factor 0.023 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.97 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) FIRST FLOOR 1260 27985 18963 638 868 SECOND FLOOR 969 20236 11312 461 518 Entire House 2229 48221 24025 1100 1100 Other equip loads 0 0 Equip. @ 0.92 RSM 22103 Latent cooling 787 TOTALS I 2229 I 48221 I 22890 I 1100 I 1100 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Sep-12 06:48:03 ^,. -r wrlghtsoft Right-Suite®Universal 2012 12.0.11 RSU17313 Page 1 AC ...Documents\Wrightsoft HVAC\RICHIE'S PECOY A18 VILLAGE HILL.rup Calc=MJ8 Front Door faces: