38A-132 (2) RICHIE'S AIR CONDITIONING & HEATING INC.
P.O. BOX 407 • 81 INDUSTRIAL LANE • AGAWAM, MA 01001
TELEPHONE (413) 789-1244
,�►c,► :s p fiat APPiAcAri S Rrz. Lor at _y
W '4t• rn A;4• T. GPi,e T'it^,4 p Liao AFkaw;NC. fi
tro d S}3t
TH�srl�-4{,t
R"' '►e Z)gm aA
Load Short Form Job:
wrightsoft" Date:
SECOND FLOOR By; RICHIE
RICHIE'S AIR CONDITIONING & HEATING
81 Industrial Lane,Agawam,Ma
Project Information
For: LOT A4 VILLAGE HILL, PECOY COMPANIES
NORTHAMPTON, MA
Design Information
Htg Clg Infiltration
Outside db (°F) 0 87 Method Simplified
Inside db(°F) 70 75 Construction quality Average
Design TD (°F) 70 12 Fireplaces 0
Daily range - M
Inside humidity(%) 30 50
Moisture difference(gr/Ib) 28 24
HEATING EQUIPMENT COOLING EQUIPMENT
Make n/a Make n/a
Trade n/a Trade n/a
Model n/a Cond n/a
AHRI ref n/a Coil n/a
AHRI ref n/a
Efficiency n/a Efficiency n/a
Heating input Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 °F Total cooling 0 Btuh
Actual air flow 0 cfm Actual air flow 0 cfm
Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat n/a Load sensible heat ratio 0
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
(ft2) (Btuh) (Btuh) (cfm) (cfm)
BED 3 168 5414 2317 105 124
2ND FLOOR BATH 1 84 2350 738 45 39
BED 2 209 6214 3148 120 168
BED 1 266 7646 3015 148 161
2ND FLOOR BATH 2 120 3512 1269 68 68
BED 4 168 7037 4227 136 226
SECOND FLOOR p 1015 32174 14713 622 787
Other equip loads 0 0
Equip.@ 0.92 RSM 13536
Latent cooling 969
TOTALS 1 1015 I 32174 I 14504 I 622 I 787
Calculations approved by ACCA to meet all requirements of Manual J 7th Ed.
2013-May-21 11:18:29
wrightsoft Right-Suite®Universal 2012 12.0.11 RSU17313 Page 4
ACAIN ...\Documents\Wrightsoft HVAC\RICHIE'S PECOY A4 VILLAGE HILL.rup Calc=MJ7 Front Door faces:
Load Short Form 4wrightsoft' Date:
FIRST FLOOR By: RICHIE
RICHIE'S AIR CONDITIONING & HEATING
81 Industrial Lane,Agawam,Ma
Project Information
For: LOT A4 VILLAGE HILL, PECOY COMPANIES
NORTHAMPTON, MA
Design Information
Htg Clg Infiltration
Outside db(°F) 0 87 Method Simplified
Inside db(°F) 70 75 Construction quality Average
Design TD (°F) 70 12 Fireplaces 0
Daily range - M
Inside humidity(%) 30 50
Moisture difference(gr/Ib) 28 24
i
HEATING EQUIPMENT COOLING EQUIPMENT
Make n/a Make n/a
Trade n/a Trade n/a
Model n/a Cond n/a
AHRI ref n/a Coil n/a
AHRI ref n/a
Efficiency n/a Efficiency n/a
Heating input Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 °F Total cooling 0 Btuh
Actual air flow 0 cfm Actual air flow 0 cfm
Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat n/a Load sensible heat ratio 0
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
(ftW) (Btuh) (Btuh) (cfm) (cfm)
LAUNDRY/BATH 78 2241 722 43 39
KITCHEN 182 5420 2092 105 112
DINING 190 6250 3067 121 164
FAMILY 304 15105 8888 292 475
FIRST FLOOR p 754 29017 14770 561 790
Other equip loads 0 0
Equip. @ 0.92 RSM 13588
Latent cooling 989
TOTALS I 754 I 29017 I 14577 I 561 I 790
Calculations approved by ACCA to meet all requirements of Manual J 7th Ed.
2013-May-21 11:18:29
wrightsoftt Right-Suite®Universal 2012 12.0.11 RSU17313 Page 3
...\Documents\wrightsoft HVAC\RICHIE'S PECOY A4 VILLAGE HILL.rup Calc=MJ7 Front Door faces:
4 �a. Load Short Form Job.
1Nt'1t,,, 1tsoft�° Date:
BASEMENT By: RICHIE
RICHIE'S AIR CONDITIONING & HEATING
81 Industrial Lane,Agawam,Ma
Project Information
For: LOT A4 VILLAGE HILL, PECOY COMPANIES
NORTHAMPTON, MA
Design Information
Htg Clg Infiltration
Outside db (°F) 0 87 Method Simplified
Inside db(°F) 70 75 Construction quality Average
Design TD(°F) 70 12 Fireplaces 0
Daily range - M
Inside humidity(%) 30 50
Moisture difference(gr/Ib) 28 24
HEATING EQUIPMENT COOLING EQUIPMENT
Make n/a Make n/a
Trade n/a Trade n/a
Model n/a Cond n/a
AHRI ref n/a Coil n/a
AHRI ref n/a
Efficiency n/a Efficiency n/a
Heating input Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 °F Total cooling 0 Btuh
Actual air flow 0 cfm Actual air flow 0 cfm
Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat n/a Load sensible heat ratio 0
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
(W) (Btuh) (Btuh) (cfm) (cfm)
FINISHED BASEMENT 504 2476 518 48 28
BASEMENT p 504 2476 518 48 28
Other equip loads 0 0
Equip. @ 0.92 RSM 477
Latent cooling 0
TOTALS 1 504 I 2476 I 477 I 48 I 28
Calculations approved by ACCA to meet all requirements of Manual J 7th Ed.
2013-May-21 11:18:29
4...,'. wrightsoft Right-Suite®Universal 2012 12.0.11 RSU17313 Paget
/ ...\Documents\wrightsoft HVAC\RICHIE'S PECOY A4 VILLAGE HILL.rup Calc=MJ7 Front Door faces:
4 Load Short Form Job:
W rights �f ` Date:
Entire House By: RICHIE
RICHIE'S AIR CONDITIONING & HEATING
81 Industrial Lane,Agawam,Ma
Project Information
For: LOT A4 VILLAGE HILL, PECOY COMPANIES
NORTHAMPTON, MA
Design Information
Htg Clg Infiltration
Outside db (°F) 0 87 Method Simplified
Inside db(°F) 70 75 Construction quality Average
Design TD (°F) 70 12 Fireplaces 0
Daily range - M
Inside humidity(%) 30 50
Moisture difference(gr/Ib) 28 24
i
HEATING EQUIPMENT COOLING EQUIPMENT
Make Make
Trade Trade
Model Cond
AHRI ref Coil
AHRI ref
Efficiency 80 AFUE Efficiency 0 SEER
Heating input 0 MBtuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 °F Total cooling 0 Btuh
Actual air flow 1231 cfm Actual air flow 1231 cfm
Air flow factor 0.019 cfm/Btuh Air flow factor 0.053 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.92
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
(ft2) (Btuh) (Btuh) (cfm) (cfm)
FIRST FLOOR p 754 29017 14770 561 790
BASEMENT p 504 2476 518 48 28
SECOND FLOOR p 1015 32174 14713 622 787
Entire House d 2273 63666 23019 1231 1231
Other equip loads 0 0
Equip. @ 0.92 RSM 21178
Latent cooling 1957
TOTALS I 2273 I 63666 I 23135 I 1231 I 1231
Calculations approved by ACCA to meet all requirements of Manual J 7th Ed.
2013-May-21 11:18:29
,�. wrightsoft� Right-Suited Universal 2012 12.0.11 RSU17313 Page 1
AS. ...\Documents\Wrightsoft HVAC\RICHIE'S PECOY A4 VILLAGE HILL.rup Calc=MJ7 Front Door faces:
AMIIIIIIIIIIMPr
i
INSURANCE COVERAGE:
I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L.Ch.112 Yes No❑
If you have checked Yes, indicate the type of coverage by checking the appropriate box below:
A liability insurance policy [ Other type of indemnity ❑ Bond ❑
OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the
Massachusetts General Laws,and that my signature on this permit application waives this requirement.
Check One Only
Owner 0 Agent ❑
Signature of Owner or Owner's Agent
1
By checking this box hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and
accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be
in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws.
Duct inspection required prior to insulation installation:YES NO
Progress Inspections
Date Comments
Final Inspection
Date Comments
Type of License:
By ]Master
Title
❑ Master-Restricted `Oki).
City/Town
❑Journeyperson Signature of Licensee
Permit*
❑Journeyperson-Restricted License Number:_$ ❑ -
Check at www.mass.qov/dol
Inspector Signature of Permit Approval
Commonwealth of Massachusetts
P� 21%1/
M Sheet Metal Permit
G 1NS
u'�gt�, a'':`, 1v1 Permit# 013 to 1
} g �
Estimated Job Cost: $ 5,�'�" Permit Fee: $ 'was Ito
Plans Submitted: YES NO t. Plans Reviewed: YES NO
Business License # Applicant License # J r
Business Information: Property Owner/Job Location Information:
Name: Pati11CS Aix Ga..t11- 2AC Name: k ct.cC P Gw(z. S kitinz4
fot 41617
Street: %I ZA004,212, LA Street: (0. i...451"
City/Town: 41C4 U)NM MA* CAW 04x11 City/Town: N i "'QIP mi\ Uis9F,®
Telephone: x'1'3 1 n-- 1144 Telephone: Li IS- 181" v
Photo I.D. required /Copy of Photo 1.D. attached: YES NO
Staff Initial
J-1 /M-1-unrestricted license
J-2 /M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less
Residential: 1-2 family ✓ Multi-family Condo /Townhouses Other
Commercial: Office Retail Industrial Educational
Institutional Other
Square Footage: under 10,000 sq. ft. ✓ over 10,000 sq. ft. Number of Stories:
Sheet metal work to be completed: New Work: Renovation:
HVAC ✓ Metal Watershed Roofing Kitchen Exhaust System
Metal Chimney /Vents Air Balancing
Provide detailed description of work to be done:
N A O Q; rA Ao-► VE+4'1'3 RI et V G-N-r, k,cGHG� Pc L0 1
VitE31.4 AIR. I$C1.441I4 AIL
File#SM-2013-0061
APPLICANT/CONTACT PERSON RICHIES AIR CONDITIONING&HEATING INC
ADDRESS/PHONE P 0 BOX 407 (413)789-1244 0
PROPERTY LOCATION 92 MOSER ST-UNIT A4
MAP 38A PARCEL 132 ZONE PV
THIS SECTION FOR OFFICIAL USE ONLY:
PERMIT APPLICATION CHECKLIST
ENCLOSED REQUIRED DATE
ZONING FORM FILLED OUT
Fee Paid
Building Permit Filled out 0 Lei
Fee Paid Ao-K o�
Typeof Construction: COMPLET AIR DUCT SYS,INCL BATH,KITCHEN FAN&DRYER VENTS
New Construction
Non Structural interior renovations J if
Addition to Existin_ , , ,
Accesso Structure � _ _Ilp ,,S
Buildin• Plans Included: ��E�'
Owner/Statement or License 273 or '
3 sets of Plans l Plot Plan
THE F LOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON
I RMATION PRESENTED:
Approved Additional permits required(see below)
PLANNING BOARD PERMIT REQUIRED UNDER: §
Intermediate Project: Site Plan AND/OR Special Permit with Site Plan
Major Project: Site Plan AND/OR Special Permit with Site Plan
ZONING BOARD PERMIT REQUIRED UNDER: §
Finding Special Permit Variance*
Received&Recorded at Registry of Deeds Proof Enclosed
Other Permits Required:
Curb Cut from DPW Water Availability Sewer Availability
Septic Approval Board of Health Well Water Potability Board of Health
Permit from Conservation Commission Permit from CB Architecture Committee
fr., lm treet Co •• 'ssion Permit DPW Storm Water Management
�.— r� S7-3 11,5
Sign. . of guild ng •ffi ial Date
Note:Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning
requirements and obtain all required permits from Board of Health,Conservation Commission,Department
of public works and other applicable permit granting authorities.
*Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact the Office of
Planning&Development for more information.
92 MOSER ST - UNIT A4 SM-2013-0061
COMMONWEALTH OF MASSACHUSETTS
--- -- -- ----
CITY OF NORTHAMPTON
�GIS#: 12107
Map 38A
Block. 1 32 40 ;. SHEETMETAI, PERMIT
Lot:
. , _%�
Permit: SHEETMETAL II cENTENPj
Category: SHEETMETAL
Permit# SM 2013-0061 _ PERMISSION IS HEREBY GRANTED TO:
Project# JS-2013-001463
Est Cost: $5,000.00 Contractor: License: Expires:
Fee Charged:$25.00 RICHIES AIR CONDITIONING&HSheetmetal-273 03/15/2013
i
Balance Due:$.00 Owner: KENT PECOY&SONS CONSTRUCTION INC
#of Fixtures: Applicant: RICHIES AIR CONDITIONING&HEATING INC
DtgSafe# AT: 92 MOSER ST-UNIT A4
lise Grroup
C' onstClass
ISSUED ON: 05-Jun-2013 AMENDED ON: EXPIRES ON:
TO PERFORM THE FOLLOWING WORK:
COMPLET AIR DUCT SYS,INCL BATH,KITCHEN FAN&DRYER VENTS-*line drawings required*
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Signature:
Fee Type: Receipt No: Date Paid: Check No: Amount:
Sheetmetal REC-2013-006387 22-May-13 16086 $25.00
212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:lhasbrouck @northamptonma.gov
GeoTMS®2013 Des Lauriers Municipal Solutions,Inc.