Loading...
38A-134 28. Dwelling/Garage fire separation.An attached garage (within 3'of main structure) is required to have 1/2" drywall on the garage side of the separation wall and if there is a finished space above the garage all walls must have%2" drywall and the ceiling 5/8" drywall. 780 CMR R302.6 29. Energy aspects shall comply with the stretch energy code.780 CMR Appendix 115AA or 2009 IECC. a. An initial HERS evaluation is required including insulation levels anticipated. b. A final HERS evaluation confirming code requirements have been met including duct testing. c. Energy information including mechanical equipment posted on the electric panel. d. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy Star Building Option Package. 30. Vapor retarders.Although these are still in the code have exceptions, one must understand that there is a difference between a vapor retarder or barrier and an air barrier.An air barrier is intended to stop air flow(convection) a vapor retarder or barrier is intended to stop molecular moisture transfer(diffusion). A vapor retarder or barrier is effective even if there are some holes or gaps, however an air barrier has to be absolute and complete. If air can leak through an electrical device or through a crack it follows the path of least resistance and carries 99%of the moisture in a structure.This is evident every time one exposes fiberglass insulation and finds black insulation, which is dirt filter out of the air moving through the insulation. 780 CMR R601.2 for vapor retarders and Table N1102.4.2 for air sealing requirements. 31. Unvented attic assemblies. Hot roofs are allowed, but have specific requirements 780 CMR R806.4. 32. Deck ledgers and post must be appropriately attached, bolts or lags. 780 CMR R502.2.2.1 Note:ThruLoks are engineered for post attachment supporting a railing. 33. Smoke and CO detectors as required. 780 CMR R314 and R315. 34. Closets beneath stair which have doors must be drywalled with%2". 780 CMR R302.7 Relevant items must be submitted to the building department for approvals before inspections and or CO can be signed.Other items are intended to avoid costly issues at inspections. Feel free to call if you have any questions. My telephone number is 587-1240 and office hours are Monday through Friday,8:30 am to 4:30 pm, excepting we close for walk-ins at 12:00 noon on Wednesdays. My email address is: cmiller aC�northamptonma.gov Thank you for yo ••••- .ti n on these matters. Chuck Mill- e City of Northampton Assistant Commissioner and Zoning Enforcement 12. A complete window and header schedule is required.780 CMR Table R502.5 for header sizing and number of jack studs required. 13. All framing materials which are not code prescriptive must have stamped engineering. a. LVLs b. I-joist and or Floor Truss c. Roof truss 14. A braced wall plan identifying appropriate braced wall areas and braced wall method being used.780 CMR 602.10. a. Garage corners and large corner window/door layout may require special solutions. b. All corners must be appropriately attached to the foundation. 15. Ceiling heights minimum 7'for habitable spaces, 6'8"for bathrooms includes tub/shower area if a shower head is used, 6'8" for basements,6'4" at beams/ducts.780 CMR R305.1. MA amended 16. Hazardous glazing locations, within 24" of a door, or within 60"of a stair,or across from hot tubs, spas, bathtubs within 60" if not 60" above the walking surface, and other locations.780 CMR R308.4 17. Windows over 72"above grade with the opening less than 24 above the finished floor shall meet the 4" sphere rule. Order restrictors. 780 CMR R612.2 18. Egress and emergency escape requirements shall be strictly met. a. Basements, habitable attics, and all sleeping rooms require emergency escape.780 CMR R310 b. Windows within 44" of floor, DH 3.3 sqft min window size, Casement 20"x41" exception 5 sqft at 15t floor. Minimum clear opening 20"x24"or 24"x20". 780 CMR R310.1.1 c. Two doors remote as possible at the normal level of travel, opening measured from the face of the slab to the stop with door at 90 degrees,one 32" and one 28" minimum 78" high. 780 CMR R311.2 d. Landing at each door 36" out and the width of the door minimum 36", maximum step 7%"from the top of the threshold and only in-swinging doors. 780 CMR R311.3 19. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9", maximum riser 8%", maximum overall variance for the run is 3/8",4" sphere rule on risers except where the total rise is 30"or less 780 CMR R311.7.4.3 Exception,4 3/8"on balustrade, 6" in the triangle. Graspable rail 1''A" minimum and 2" maximum rail, height minimum 34" maximum 38", required for 4 or more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling height from nosing. 780 CMR R311.7. 20. Guards 36" minimum height above walking surface, a bench is a walking surface, required for more than 30" above floor or grade within 36",4"sphere rule.780 CMR R312.1. 21. Educate the plumber and electrician about maximum notch and hole sizes, and placement. 780 CMR R502.8 and R602.6. In bearing studs holes not larger than 40%of a stud no closer than 5/8 to the edge, In interior non-bearing studs holes not larger than 60%of a stud no closer than 5/8 to the edge, in bearing walls if more than 50%of a plate is cut or notched a 1 Y2" 16ga.strap must extend a minimum of 6" past the cut both directions and be nailed with 8-10d per side,or holes in joist are a maximum 1/3 the depth not closer than 2"from the top or bottom. Notches are different. 22. Dryer duct transition is limited to 8'of aluminum flex and must be exposed. 780 CMR M1502.4.3 23. Dryer duct maximum equivalent length is 25'or per manufacturer's specs.780 CMR M1502.4.4.1, no screwed connections. 24. Markup air is required for any exhaust hood of 400 CFM or more. 780 CMR M1503.4 25. Fireplaces require all combustion air be provided from the exterior and below the firebox, duct work maintaining 1"clearance for 5'from the duct outlet for all fireplaces 26. Fire and draft stopping shall be completed before rough inspection. 780 CMR R302. 27. Ignition barriers in place before final. 780 CMR R316. City of Northampton SMAM Massachusetts 4w .1. •fc * �" ,fit t# ;w `' i DEPARTMENT OF BUILDING INSPECTIONS s 11,4 `' 212 Main Street • Municipal Building 0' .,. ' qyr r Northampton, MA 01060 ` c INSPECTOR Kent Pecoy&Sons Construction May 21, 2012 215 Baldwin Street West Springfield, MA 01089 Subject Location:86 Moser Street Lot#21 Map Block: 38A-134 Mr. Pecoy, Please follow up on the following items: 1. An electronic copy of the building plans and engineering. 2. Stamped structural drawings are required for all none code prescriptive framing. Some examples are I-joist, LVLs, floor or roof truss. 3. A smoke/CO detector is required at the bottom of 1st floor stair leading to the finished floor above. 4. There is a requirement for the HVAC contractor to take a sheet metal permit, with this a room by room heat loss calculation done with manual J Edition 8, a line drawing showing supply and return CFMs,and equipment specifications are required. If this is not done it will hold up the final CO. 5. Planning Decision Hearing conditions of approval#2,9, 12, and 13. Proof of completion required. 6. Copies of the final HERS, Duct Blast Test, signed Thermal Bypass Checklist, and Energy information posted on the electric panel. As of August 4th 2011 the 8th Edition MA code is the 2009 IRC with MA amendments. In the following are some generic requirements which seem to be problematic. This is not a substitute for purchasing and reading the MA codes. 1. Structures shall conform to 780 CMR 8th Edition 1 and 2 family building codes with MA amendments. 2. Grading plan for structures being constructed required. 780 CMR R401.3 for drainage requirements. 3. A basement drainage system is required in all basements 780 CMR R405.2.3. except those in group I soils (table R405.1) 4. Foundations that retain earth and enclose interior space require damp proofing 780 CMR R406.1. 5. Through wall form ties must be removed from both faces and patched with hydraulic cement. 780 CMR R406.2 of amendments. 6. Foundation anchor bolts must be%Z" and be embedded a minimum of 7" into the concrete. 10" bolts! 780 CMR R403.1.6 7. Foundation walls require horizontal reinforcement 2#4 bars one within 12"of the top and one in the middle if 8'or less and 3#4 bars at top and 3rds if over 8'. 780 CMR R404.1.2(1).Also see vertical reinforcement requirements. 8. CMU foundations require 3/8" parging before damp proofing.780 CMR R406.1 see exceptions. 9. Ceiling joist are intended to prevent spread,once raised above the wall plate they become rafters ties and may require up sizing of rafters and increased nailing for example with a 4"slope 8-16nd common are required at each connection. 780 CMR R802.3.1. When there is neither of these a structural ridge is required with a load path to the foundation. 10. Steel straps over the ridge or 1x4 minimum collar ties are required 4'OC in the upper l/3rd780 CMR R802.3.1 11. Ridge boards must be the full depth of the cut. 780 CMR R802.3. Cc: Building Inspector (SUBJECT TO ATTACHED CONDITIONS 1 & 2) Permit No. D25-13 Conditions: Driveway Permit In lieu of plan approved by the City Engineer I agree to the following added conditions: 1. I will contact the Department of Public Works and have an inspector check and approve the graded gravel base prior to paving to insure compliance with slope and location; 2. I further agree that if in the inspections, any of the permit conditions are not met that I will at no expense to the City remove and replace the driveway as directed by the City Engineer. By: Petitioner Signature Name: Don Clarke/Kent Pecoy & Sons Address: 215 Baldwin Street West Springfield, MA 01089 Note: The Public Works Department recommends that you provide a plan showing the proposed driveway with grades and location in the future to avoid possible expense which you will incur by not getting approval of actual plans in advance. For Commercial and Industrial applicants, a plan showing the proposed driveway with grades, location and Planning Board permits are required. Cc: Building Inspector u I�i • Permit No. D25-13 CITY OF NORTHAMPTON, MA DRIVEWAY PERMIT Date: 5/2/13 Check#: �3 6 a FEE: $250.00 THE BOARD OF PUBLIC WORKS Driveway must be staked and house & lot number posted The undersigned respectfully petitions your honorable body for: A new Curb Cut Permission to install a driveway at: 86 Moser Street, Lot A21 Fifteen (15) foot maximum width from street line to property line. Gutter drainage not to be disturbed. All drainage shall be directed off the driveway surface to adjacent land and not on the existing roadway. The first one hundred (100) feet of the driveway surface shall be paved as soon as possible if the grade of the proposed driveway exceeds 3% at any point in the first one hundred (100) feet. Homeowners will be held responsible for any costs to the City of Northampton in the event of a washout of this driveway. City is not responsible for culverts installed under driveways in City layout. Code of Ordinances §350-8.8 providing standards for private, individual driveways as most recently amended, must be followed. By: Kent Pecoy & Sons / Don Clarke Telephone: / 413-246-3749 I ature: �i� Ai� / � Proposed Location Inspection By: c...4 !' • Gravel Base Grade Inspected By: Final Approval: THE BOARD OF PUBLIC WORKS voted that petition be granted. Edward S. Huntley, P.E. GWGAS ONVIO Director.of Public Works � 7a 3 i COMM +kilo a, MUNICIPAL SEWER!AVAILABILITY APPLICATION Northampton Streets Department 125 Locust Street Northampton, MA 01060 587-1570 A Department of Public Works Trench Permit and Sewer Entry Permit shall be required prior to any construction or connection activity associated with this application. Location: 86 MOSER STREET, LOT A21 Inquiry Made By: Don Clarke Kent Pecoy & Sons 246-3749 Date of Inquiry: 5/2/13 Reason for Request: New Construction Hook into water, driveway and sewer Municipal Sewer Main in Front of Location: Yes No Municipal Storm Drain Available: 5 1/2 deep Yes No Size of Sewer Main: Material: Age: Depth of Sewer Main: Length of Sewer Main: Size of Service Connection: Type of Service Connection: Tie-in to Sanitary Main Tie-in to Sanitary Stub Comments: R. I4ria Ic Note: If this availibility is for new construction, this form must be hand delivered to Building Inspector. A corresponding"sewer entrance fee"shall be paid prior to making any connection to the municipal sewer system.Arrangements of such installation shall be made with the Northampton Streets Department with a minimum of 5 working days notification. All work shall conform to Northampton Streets Department specifications. John Hall Sewer Department cc: Ned Huntley, Director DPW Louis Hasbrouck, Building Commissioner MUNICIPAL WATER AVAILABILITY APPLICATION Northampton Water Depaituient 237 Prospect St. Northampton, MA 01060 587-1097 A Department of Public Works Trench Permit shall be required prior to any construction or connection activity associated with this application. Location: 86 Moser Street, Lot A21 Inquiry Made By: Don Clarke Kent Pecoy&Sons 246-3749 Date of Inquiry: 5/2/13 Number of Type of Single Family X Type of Private X Units: 1 Unit(s): Apart. Comm Ownership: Condo Multi-family Rental (Annlicant to fill out the above) Municipal Water Main in Existing service to Front of Location? Yes: X No: site? Yes: X No Size of Water Main: 8" Material: Ductile Iron Age: 2009 Approximate Static Street Flow Test Conducted:Yes: No: X Pressure: 85 psi If done attach results Size of Service Connection 1" Suggested Meter Size: 5/8" Comments: The Water Department cannot guarantee adequate water pressure during peak demand times at elevations above 320 feet. • A corresponding water entrance fee shall be paid prior to making any connection to the municipal water system. • Arrangements of such installation shall be made with the Northampton Water Department with a minimum of 5 working days notification. All wo shall conf t ort mpton Water Department specifications. David W. Sparks, Superintendent of Water Dept. Water Entry $200.00 Meter$100.00 Radio $100.00 cc: Ned Huntley,Director cc: Louis Hasbrouck, Building Commissioner Note: If this availability is for a new construction, it must be hand delivered to the Building \-)c(1 Inspector. ( / ----i --— / / \ NI , 1 \ N's.N.,.......\.s... „,, I ....1 I I.-1 i I- 1 ) -7-'/' ‘j V/- (TYF _ _ -- -- ; ! I ' ...? ' ,..",■) - , // , , , \ / -7,-- — 11 7/ ) . \ ,-• • ,/ / 7 ) ) lit ' / ,±y_,_A.:FA„,,,,,,„L--- .F SF .„."---4.?”''''•,==.-,...'r --i 216 \-- ! -- ■ ..--- , / • • / t2, ,7 • i ii . . . . _,- . a •4. ' •') 7/ • ,,„4 . ' i___ ___:.. ....,"_ ____ ___ 7__ , __ ___ — • - '‘• - • . 4/ , - , ..•••••"` -f- --4,-. I ,. .,,J:jr,„-- v v ,k.,,:,, r• • './ ,___„_, t t • '•-. , . , J____I--,- -----iA - — -- "; , , ,,,, : Lii, ,,, ,,:,, ,_, it.:17tdoi , LOT A4 A4:, i (.1 LOT A6 I IT LA- 0 o3 FF 5.i; _ • " N 1 21 S `,•'H -AN, 1219...25 c7J 219.501 1---k, : ., —-, i • - ; ,, .. 41,-, 4 . .....it_ _. . , - •',-.•P'''' ,( . . . , • - 1 ., c------/' '.•,--- , , :, - --- .. ., , ('''' \ „...-4. w-, ... . „. ,_ (?. ©2 I , •, 4 4 f. f '•.' . •'4:-:' BASIN A I: 1::-R-:‘----':' 1 >1". ''' '''.''.\' - . i • , t -.)(.,\ / r \ i t '; / '©((j1 ( ' - -•---- 1 . (7.--- ''s,, ( /I II ' -,..---rj- r\-- , kft \ ; :1 , ';1 i , 1 / i ; ; - N ' i t 1 ,;.'■ II I . 1 ,'t ,, i .."/ ri If--,C1- Ad . v il ,ir II \ I 1; 1‹) 1 .. 1 .1 I. __-= i le I • LOT A3 • FF ol ci oc LOT A5 FF ) \--- )1Q c ----'. . , PROPOSED SITE PLAN • KATE & DEBBY LOT A21 VILLAGE HILL 7 NORTHAMPTON, MA • ,jr, �}.�. .per ��7T,}y •!� �r - A;•? -... - 4YJ:LL 4�1 �i.CiLG.i1 L.fi LU1► A• - - $a 'tom /•`:i , SBL�Efif ' ~ DEPARTMENT OF BUILDING INSPECTIONS �� INSPECTOR 212 Main Street it Municipal Building a Northampton,MA 01060 u° LOCATION ?6 M 6 c'R ,S 2 f2c'17 t I A- -pl / Vi i t /4-�n( gill - iveit- , / -""0 Lc/ . • SQUARE FOOTAGE AMOUNT • BASEMENT @ :20 /, iTY%•T 3r 81 lsTFLOOR @.50 j, / --Lt ,S-r-7 7 m 2ND x@30 %FLOORS, FJNISH A ,GARAGE 20 ff g/ 'S-7 DECK/PORCHES @ -•20 - o • TOTAL-. /, /‘8�� • • • • A l' CERTIFICATE OF LIABILITY INSURANCE DATE 0(2 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. MPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(iss)must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Irene Belize Alexander W Borawski Inc PHONE „ (413)566-5011 1 (413)S96-7973 88 King Street, Suite B ADDRE :ibaliseeborawskiinsnrance.com INSURERIS)AFFORDING COVERAGE NAIL I Northampton MA 01060-3257 INSURER A Netherlands Insurance 24171 INSURED Hamm a:Peerless Insurance 24198 Kent Pecoy & Sons Construction, Inc INSURERCMELBA; Employers Ins. Co. 215 Baldwin St INSURER D: INSURER E: West Springfield MA 01089 INSURER F: COVERAGES CERTIFICATE NUMBER:CL1172200146 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CCLAIMS. Walt TYPE OF INSURANCE SR.VD POLICY NUMBER ( DYIYYYYI (MhtmOr cl STS GENERAL UABIUTY EACH OCCURRENCE $ 1,000,000 —X COMMERCIAL GENERAL LIABILITY DAMAGE TO a%curr PREMISES(Ea oecurtencq) $ 100,000 A 1 CLAIMS-MADE Fin OCCUR C8P8780556 7/1/2011 7/1/2012 MEDEXP(Any one person) $ 5,000 PERSONAL SADVINJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 GEM AGGREGATE UNIT APPLIES PER. PRODUCTS-COMP/OP AGO S 2,000,000 POLICY n tECOT r�LOC .. ._-_ _ $ AUTOMOBILELIABILm ” (C�DI I SINGLE LIMIT S 1000000 — ,AUTO BODILY INJURY(Per person) $ AN — ALL OOWNED 0 AUTOS SA8781850 7/1/2011 7/1/2012 BODILY INJURY(Per accident) $ AUTOS X HIRED AUTOS AUTOS ED (PROP (e tOAMAE S Underinsraed motorist Al split $ X UMSREU.ALIAR X OCCUR EACH OCCURRENCE $ 5,000,000 B EXCESS LIAB CLAIMS-MADE AGGREGATE $ 5,090,000 DED X RETENTIONS 10.00' CU8783651 7/1/2011 7/1/2012 $ C WORKERS COMPENSATION ORYTWM TS "ER AND EMPLOYERS LIABILITY Y I N ANY EXCLUDE EXECUTIVE[N NIA 6/30/2011 6/30/2012 El.EACH ACCIDENT $ 5001 OOO (Mandatory NN) L MCC2000239012011 E.L.DISEASE•EA EMPLOYEE S 500,00 0 DESC�N OF OPERATIONS below, E.L.DISEASE-POLICY LIMIT S 5001 000 DESCRIPTION OF OPERATIONS!LOCATIONS 1 VEHICLES (Attach ACORD 101,Additional Remarks Schedule,if more space Is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. City of Northampton 212 Main Street AUTHORIZED REPRESENTATIVE Northampton, MA 01060 R Borawski/BORIB1 `sCr.f# 37 T-A54 "0'"C ACORD 25(2010105) ®1988-2010 ACORD CORPORATION. All rights reserved. iNS025 oni nag%ni The ernafl nom°and Inn^are raniahara l marks of Arnim) SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder: f Alf d S License Number )/5 , '1 I u t 5'• "?f£( LJ, _/k, f t FC) 41;4 ()/ u q- / - i3 Address Expiration Date Signa re Telephone 9.Registered Home Improvement Contractor: Not Applicable ❑ ,�fti7 / ;JC -3 Ott'S�k?cC //)/) lice /C ? 76, 7 Company Name Registration Number )%5" ,(jfl ,�t�'ot' /LAP S/k?i� f i�f.d 414 7 ` 3/ • •c'/ Address Expiration Date Telephone//' ie'/ /« d' SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes No ❑ 11. - Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature ISECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) /// /New House 0 Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ ___-/ Or Doors El Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [Q Siding[0] Other[p] Bppief Description of Proposed l` 4'._cfz,t.744L Alteration of existing bedroom Yes No Adding new bedroom _Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building : One Family 47 Two Family Other b. Number of rooms in each family unit: /Z' Number of Bathrooms c. Is there a garage attached? AT d. Proposed Square footage of new construction. -L J e Dimensions X/ / cJ e. Number of stories? , f. Method of heating? 6-45 `2 4--iv2 Fireplaces or Woodstoves C71E7hPi-,v6c Number of each g. Energy Conservation Compliance. Y£S Masscheck Energy Compliance form attached? h. Type of construction G1)0D b / i. Is construction within 100 ft. of wetlands? Yes 1 No. Is construction within 100 yr. floodplain Yes XNo j. Depth of basement or cellar floor below finished grade '7 1 k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer ,// Private well City water Supply ‘,r- SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNER S/AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, / itn /4-a/ , as Owner of the subject property r hereby authorize C�-', C 14/c- C to act on my behalf, in all matt)relative to work authorized by this building permit application. Signature of`'owner Date 5 / 3 - 15 I, //tit i / a,/ , as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signe under th pains and penalties of perjury. Ott.% , a rat Print Name k'.- S- /3 — /3 Signature of Owner/Agent --- Date //k //E1) /pct /,c -ice Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage Open Space Footage (Lot area minus bldg&paved parking) #of Parking Spaces Fill: (volume&Location) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO Q DON'T KNOW 0 YES 0 IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DON'T KNOW Q YES 0 IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO Q DONT KNOW 0 YES Q IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Q Obtained Q , Date Issued: C. Do any signs exist on the property? YES Q NO Q IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES Q NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES Q NO Q IF YES, then a Northampton Storm Water Management Permit from the DPW is required. Department use only r-- RRECEIVED ity of Northampton Status of Permit <iL�V�D uilding Department Curb Ct�veway Permit. 212 Main Street Surat/SeOCAvailability MAY 15 � Room 100 Water/Well Availabitl`ty No hampton, MA 01060 TwoSe14 oStructural Plans DEPT.OF BUILDING I ,�,T 13-.87-1240 Fax 413-587-1272 P#e't% t¢ ,aqs NORTHAMPTON other Specify, APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION r This section to be completed by office 1.1 Property Address: L%//rt % Alf if , _A Map e g 7/_ Lot /f 31 Unit Zone Overlay District /,'0/1,',14;41 'i eiti ,14.4 : L7/fL 6 Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: A /6H'/ /<<c"I d -S ,S re l,)(;I t'(` /16'0 ?2/S ;/44`Zi).L . c:01 7-, III, CA)/A.,f�' 1/1 i./r�tk, Name(Print) Current Mailing Address: Telephone Signature ' 2.2 Authorized Agent: )/{; /'("/; /2 >s )/5 1 ,/Z.i)t,lR. C//2 7 IL'. Sf)')//t IFtL1LI 44/4. Name( ant} Current Mailing Address: �� �;��� 1//s '.Ye I/ ` ..9679 Sig ature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building (a)Building Permit Fee 2. Electrical / (b)Estimated Total Cost of //•roc Construction from(6) 3. Plumbing 41. O Building Permit Fee 4. Mechanical(HVAC) �S 4c' `L 5. Fire Protection 6. Total=(1 +2+3+4+5) I ig/', /SD °=- _ Check Number 58(G.69 $/>//O O id U 419"(// This Section For Official Use Only Building Permit Number: _- Date Issued Signature: Building Commissioner/Inspector of Buildings Date (*.II-6 51--caerg.,A44.70)A4 File#BP-2013-1094 S I'r7. 3 C_ II.Pt- APPLICANT/CONTACT PERSON KENT PECOY&SONS CONSTRUCTION INC ADDRESS/PHONE 215 BALDWIN ST WEST SPRINGFIELD (413)781-7008 VW&I C`<_ PROPERTY MAP 38A PARCEL 134 ZONE PVST � THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out / // 14 0-0 Fee Paid 2 3 t Typeof Construction: CONSTRUCT SINGLE FAMILY RESIDENCE W/PORCH/DECK New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 052589 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFOj2MATION PRESENTED: L/Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission _ Permit DPW Storm Water Management op: �,Dela 7- 4 l ,/f Signa re of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. 86 MOSER ST BP-2013-1094 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 38A- 134 CITY OF NORTHAMPTON Lot: - PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category:New Single Family House BUILDING PERMIT Permit# BP-2013-1094 Project# JS-2013-001808 Est. Cost: $281150.00 Fee: $1168.20 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: KENT PECOY & SONS CONSTRUCTION INC 052589 Lot Size(sq. ft.): 12623.00 Owner: KENT PECOY&SONS CONSTRUCTION INC Zoning: PV Applicant: KENT PECOY & SONS CONSTRUCTION INC AT: 86 MOSER ST ,404-02/ Applicant Address: Phone: Insurance: 215 BALDWIN ST (413) 781-7008 WC WEST SPRINGFIELDMA01089 ISSUED ON:5/22/2013 0:00:00 TO PERFORM THE FOLLOWING WORK:CONSTRUCT SINGLE FAMILY RESIDENCE W/PORCH/DECK POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 5/22/2013 0:00:00 $1168.20 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner