Loading...
25C-255 (3) KeyBuild StructureTM2.06[Build 7] OberJeremy23FerrisSt-Level 6 5-9-13 kmBeamEngine 4.600y Materials Database 1411 2:52pm 2 of 2 Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS NOTE:Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. No lateral bracing required along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 7367.'# 13958.'# 52% 11.09' Even Spans D+L Negative Moment 8080.'# 13958.'# 57% 15.5' Adjacent 2 D+L Negative Unbrcd 8080.'# 13958.'# 57% 15.5' Adjacent 2 D+L Shear 5099.# 6317.# 80% 14.76' Adjacent 2 D+L TL Deflection 0.1157" 0.3708" L/769 11.79' Even Spans D+L LL Deflection 0.0958" 0.2472" L/929 11.79' Even Spans L Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives Point loads over bearings are NOT included in the Design calculations,but ARE included in the Reaction table All product names are trademarks of their respective owners Copyright(C)1987-2012 by Keymark Enterprises,LLC.ALL RIGHTS RESERVED. K E Y M A R K "Passing is defined as when the member,floor joist,beam or girder,shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval.This design assumes product installation according to the manufacturer's specifications. 1 KeyBudd structurei°'2.06[Build 7] OberJeremy23FerrisSt-Level 6 _ 5-9-13 / c)_ 5 c IcrnbearnEngine 4.600y t/��) Materials Database 1411 ICI--- ✓ 2:52pm POC.>i /-„Ck O U CFit l 1 of 2 Member Data Y Description: CaIcG1 Member Type: Girder Application: Floor Comments: Carrying beam Top Lateral Bracing: Continuous Bottom Lateral Bracing: (See Below) Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total 2.000" max. LL Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 9.4 PLF Filename: Q:\OberJerem Other Loads Type Trib. Other Dead (Description) Side Begin End Width Start End Start End Category Replacement Uniform(PLF) Top 0' 0.00" 11' 1.00" 260 65 Live Replacement Uniform(PLF) Top 0' 0.00" 11' 1.00" 260 65 Live Replacement Uniform(PLF) Top 11' 1.00" 14' 0.00" 478 158 Live Replacement Uniform(PLF) Top 11' 1.00" 15' 0.00" 478 158 Live Replacement Uniform(PLF) Top 14' 0.00" 16' 4.00" 478 158 Live Replacement Uniform(PLF) Top 15' 0.00" 16' 4.00" 478 158 Live Replacement Uniform(PLF) Top 16' 4.00" 19' 10.00" 260 65 Live Replacement Uniform(PLF) Top 16' 4.00" 19' 10.00" 260 65 Live Replacement Uniform(PLF) Top 19' 10.00" 23' 0.00" 487 159 Live Replacement Uniform(PLF) Top 19'10.00" 23' 0.00" 487 159 Live Replacement Uniform(PLF) Top 23' 0.00" 23' 4.00" 487 159 Live Replacement Uniform(PLF) Top 23' 0.00" 23' 4.00" 487 159 Live Replacement Uniform(PLF) Top 23' 4.00" 31' 0.00" 260 65 Live Replacement Uniform(PLF) Top 23' 4.00" 31' 0.00" 260 65 Live Point(LBS) Top 0' 4.63" 2161 798 Live Point(LBS) Top 11' 1.00" 2161 798 Live Point(LBS) Top 16' 4.00" 909 252 Live Point(LBS) Top 19' 10.00" 889 252 Live Point(LBS) Top 22' 10.50" -241 123 Live Point(LBS) Top 23' 4.00" 664 232 Live Point(LBS) Top 26' 4.00" 1298 461 Live Point(LBS) Top 30' 7.38" 634 229 Live r I 1 d< `( 1 L. �'� ' a � � ,`,r�. � -, �A ,� x 4kt� r `V +� �, I^l l^l / 8 1 0 7 5 0 / 7 6 0 / 8 0 0 / p 31 0 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 5118# -- 2 8' 1.000" Wall N/A N/A 3.394" 8909# -- 3 15' 6.000" Wall N/A N/A 4.443" 11662# -- 4 23' 0.000" Wall N/A N/A 3.859" 11027# -- 5 31' 0.000" Wall N/A N/A 1.500" 3669# -- Maximum Load Case Reactions Used for applying point loads(or line loads)to carrying members Live Dead 1 3980# 1138# 2 6960# 1950# 3 9070# 2592# 4 8363# 2546# 5 2899# 771# Design spans 7' 8.375" 7' 5.000" 7' 6.000" 7' 7.375" All product names are trademarks of their respective owners Copyright(C)t987-2012 by Keymark Enterprises,LLC.ALL RIGHTS RESERVED. K E Y M A R K "Passing is defined as when the member,floor joist,beam or girder,shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval.This design assumes product installation according to the manufacturer's specifications. *wrightsofr Rig ht-J®Worksheet Job: 12 Entire House Date: Mar 11,2013 By: RON G RICH PALSA 1 Room name BED ROOM 3 LIVING ROOM 2 Exposed wall 21.0 ft 33.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 12.0 x 9.0 ft 13.0 x 20.0 ft 5 Room area 108.0 ft2 260.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter ft ( ) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12E-Osw 0.068 s 4.76 1.35 168 144 685 195 264 221 1052 299 . —G 4A5-2ow 0.470 s 32.90 21.45 24 0 790 515 24 0 790 515 . —D 1100 0.390 s 27.30 11.31 0 0 0 0 19 19 519 215 —D' 1 1J 0.600 s 0.00 0.00 0 0 0 0 0 0 0 0 11 C 16B-38ad 0.026 - 1.82 1.37 108 108 197 147 0 0 0 0 F 19A-19bswp 0.049 - 2.69 0.65 0 0 0 0 260 260 699 170 6 c)AED excursion 108 108 Envelope loss/gain 1672 965 3059 1306 12 a) Infiltration 509 84 799 132 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 1 230 Appliances/other 300 600 Subtotal(lines 6 to 13) 2180 1579 3859 2268 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2180 1579 3859 2268 15 Duct loads 5% 5% 109 79 5% 5% 193 113 Total room load 2289 1658 4051 2381 Air required(cfm) 83 85 147 123 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wr- htsotftµ 2013-Mar-11 12:52:49 -�A 9 Right-Suite®Universal 2012 12.1.01 RSU13148 Page 6 ...d Settings\Ron Gagne\My Documents\Wrightsoft HVAC\RICPAL12.rup Calc=MJ8 Front Door faces: Page 6 - wrightsoft Right-J®Worksheet Job: 12 Entire House Date: Mar 11,2013 By: RON G RICH PALSA 1 Room name BED ROOM 2 BATH 1 2 Exposed wall 25.0 ft 5.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 13.0 x 12.0 ft 5.0 x 7.0 ft 5 Room area 156.0 ft' 35.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft2°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12E-Osw 0.068 s 4.76 1.35 200 176 838 238 40 32 152 43 4A5-2ow 0.470 s 32.90 21.45 24 0 790 515 8 0 263 172 D 1100 0.390 s 27.30 11.31 0 0 0 0 0 0 0 0 0 11JO 0.600 s 0.00 0.00 0 0 0 0 0 0 0 0 11 C 16B-38ad 0.026 - 1.82 1.37 156 156 284 213 35 35 64 48 F 19A-19bswp 0.049 - 2.69 0.65 0 0 0 0 0 0 0 0 6 c)AED excursion 108 36 Envelope loss/gain 1911 1074 479 299 12 a) Infiltration 606 100 121 20 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 600 300 Subtotal(lines 6 to 13) 2517 2003 600 619 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2517 2003 600 619 15 Duct loads 5% 5% 126 100 5% 5% 30 31 Total room load 2643 2104 630 649 Air required(cfm) 96 108 23 33 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft 2013-Mar-1112:52:49 ` A66/1/4 9 Right-Suite®Universal 2012 12.1.01 RSU13148 Page 5 ...d Settings\Ron Gagne\My Documents\Wrightsoft HVAC\RICPAL12.rup Calc=MJ8 Front Door faces: Page 5 *wrightsoft Right-J®Worksheet Job: 12 Entire House Date: Mar 11,2013 By: RON G RICH PALSA 1 Room name BED ROOM 1 BATH 2 2 Exposed wall 27.0 ft 5.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 13.0 x 15.0 ft 5.0 x 9.0 ft 5 Room area 195.0 ft' 45.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12E-OSw 0.068 S 4.76 1.35 216 192 914 260 40 32 152 43 4A5-2ow 0.470 s 32.90 21.45 24 0 790 515 8 0 263 172 D 1100 0.390 S 27,30 11.31 0 0 0 0 0 0 0 0 D=11J0 0.600 s 0.00 0.00 0 0 0 0 0 0 0 0 11 C 16B-38ad 0.026 - 1.82 1.37 195 195 355 266 45 45 82 61 F 19A-19bswp 0.049 - 2.69 0.65 0 0 0 0 0 0 0 0 6 c)AED excursion 108 36 Envelope loss/gain 2058 1149 497 312 12 a) Infiltration 654 108 121 20 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 900 300 Subtotal(lines 6 to 13) 2712 2386 619 632 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2712 2386 619 632 15 Duct loads 5% 5% 136 119 5% 5% 31 32 Total room load 2848 2506 649 664 Air required(cfm) 103 129 24 34 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft 2013-Mar-1112:52:49 t ...-`A 9 Right-Suite®Universal 2012 12.1.01 RSU13148 Page 4 ...d Settings\Ron Gagne\My Documents\Wrightsoft HVAC\RICPAL12.rup Calc=MJ8 Front Door faces: Page 4 r Ad-wrightsoft Right-J®Worksheet Job: 12 Entire House Date: Mar 11,2013 By: RON G RICH PALSA 1 Room name ENTRY/LAUNDRY BATH 3 2 Exposed wall 14.0 ft 10.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 8.0 x 15.0 ft 3.0 x 7.0 ft 5 Room area 120.0 ft2 21.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 \V 12E-Osw 0.068 s 4.76 1.35 112 93 443 126 80 72 343 97 . --0 4A5-20w 0.470 s 32.90 21.45 0 0 0 0 8 0 263 172 . —01100 0.390 s 27.30 11.31 19 19 519 215 0 0 0 0 —D 11J0 0.600 s 0.00 0.00 0 0 0 0 0 0 0 0 11 C 16B-38ad 0.026 - 1.82 1.37 0 0 0 0 0 0 0 0 F 19A-19bswp 0.049 - 2:69 0.65 120 120 323 78 21 21 56 14 6 c)AED excursion 0 36 Envelope loss/gain 1284 419 662 319 12 a) Infiltration 339 56 242 40 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 600 300 Subtotal(lines 6 to 13) 1623 1075 905 659 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1623 1075 905 659 15 Duct loads 5% 5% 81 54 5% 5% 45 33 Total room load 1704 1129 950 692 Air required(cfm) 62 58 34 36 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .� wr- tlt5oft" 2013-Mar-11 12:52:49 .–�A Right-Suite®Universal 2012 12.1.01 RSU13148 Page 3 ...d Settings\Ron Gagne\My Documents\Wrightsoft HVAC\RICPAL12.rup Calc=MJ8 Front Door faces: Page 3 *wrightsoft Right-J® Worksheet Job: 12 Entire House Date: Mar 11,2013 By: RON G RICH PALSA 1 Room name KITCHEN HALUSTAIR 2 Exposed wall 10.0 ft 20.0 ft 3 Room height 8.0 ft heaUcool 16.0 ft heat/cool 4 Room dimensions 10.0 x 13.0 ft 7.5 x 12.5 ft 5 Room area 130.0 ft2 93.8 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12E-Osw 0.068 s 4.76 1.35 80 72 343 97 320 308 1466 417 . —G 4A5-20w 0.470 s 32.90 21.45 8 0 263 172 12 0 395 257 . —O 1100° 0.390 5 27.30 11:31 0 0 0 0 0 0 0 0 —0 11,10 0.600 s 0:00 0.00 0 0 0 0 0 0 0 0 11 C 16B-38ad 0.026 - 1.82 1.37 0 0 0 0 94 94 171 128 F 19A-19bswp 0.049 - 2.69 0.65 130 130 349 85 94 94 252 61 6 c)AED excursion 36 54 Envelope loss/gain 955 390 2284 917 12 a) Infiltration 242 40 969 160 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1200 0 Subtotal(lines 6 to 13) 1198 1630 3252 1077 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1198 1630 3252 1077 15 Duct loads 5% 5% 60 81 5% 5% 163 54 Total room load 1257 1711 3415 1131 Air required(cfm) 46 88 124 58 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wr- htsotFt" 2013-Mar-1112:52:49 ,.�A A Right-Suite®Universal 2012 12.1.01 RSU13148 Page 2 ...d Settings\Ron Gagne\My Documents\Wrightsoft HVAC\RICPAL12.rup Calc=MJ8 Front Door faces: Page 2 .e - -wrightsoft Right-J®Worksheet Job: 12 Entire House Date: Mar 11,2013 By: RON G RICH PALSA 1 Room name Entire House DINING ROOM 2 Exposed wall 195.0 ft 25.0 ft 3 Room height 8.6 ft d 8.0 ft heat/cool 4 Room dimensions 13.0 x 12.0 ft 5 Room area 1319.8 ft' 156.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 W 12E-Osw 0.068 S 4.76 1.35 1720 1506 7169 2038 200 164 781 222 . —G 4A5-2ow 0.470 s 32.90 21:45 176 0 5790 3776 36 0 1184 772 . —D 11D0 0.390 s 27.30 11.31 38 38 1037 430 0 0 0 0 --D 11.10 0.600 s 0.00 0.00 0 0 0 0 0 0 0 0 11 C 16B-38ad 0.026 - 1.82 1.37 633 633 1152 864 0 0 0 0 F 19A-19bswp 0.049 2.69 0.65 781 781 2099 510 156 156 419 102 6 c)AED excursion 790 162 Envelope loss/gain 17247 8407 2384 1258 12 a) Infiltration 5208 858 606 100 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants© 230 5 1150 1 230 Appliances/other 5400 300 Subtotal(lines 6 to 13) 22455 15815 2990 1887 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 22455 15815 2990 1887 15 Duct loads 5% 5% 1123 791 5% 5% 149 94 Total room load 23578 16606 3139 1982 Air required(cfm) 855 855 114 102 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2013-Mar-11 12:52:49 AO-6k 9 Right-Suite®Universal 2012 12.1.01 RSU13148 Page 1 ...d Settings\Ron Gagne\My Documents\Wrightsoft HVAC\RICPAL12.rup Calc=MJ8 Front Door faces: Page 1 Entire House d 1320 23578 16606 855 855 Other equip loads 0 0 Equip. @ 0.97 RSM 16107 Latent cooling 1499 TOTALS 1320 23578 17607 855 855 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoftY 2013-Mar-11 12:52:49 9 Right-Suite®Universal 2012 12.1.01 RSU13148 Page 2 ACCA ...d Settings Ron Gagne\My Documents\Wrightsoft HVAC\RICPAL12.rup Calc=MJ8 Front Door faces: Page 2 CSC - a _.C15- Load Short Form Job: 12 wrightsoft'- Date: Mar 11,2013 Entire House By: RON G RICH PALSA Project Information For: "OBER RESIDENCE" 23 FAIR ST, NORTHAMPTON, MA 01060 Design Information Htg Clg Infiltration Outside db (°F) 0 92 Method Simplified Inside db(°F) 70 75 Construction quality Semi-tight Design TD (°F) 70 17 Fireplaces 0 Daily range - M Inside humidity(%) 50 50 Moisture difference(gr/lb) 51 16 HEATING EQUIPMENT COOLING EQUIPMENT Make NORDYNE Make NORDYNE Trade GIBSON Trade GIBSON JS4BD SERIES Model KG7SC 054D-24B Cond JS4BD-024KB AHRI ref 5156932 Coil C7BAM01824C-B AHRI ref 5055022 Efficiency 92.1 AFUE Efficiency 11.0 EER, 13 SEER Heating input 54000 MBtuh Sensible cooling 16380 Btuh Heating output 49000 Btuh Latent cooling 7020 Btuh Temperature rise 52 °F Total cooling 23400 Btuh Actual air flow 855 cfm Actual air flow 855 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.051 cfm/Btuh Static pressure 0.10 in H2O Static pressure 0.10 in H2O Space thermostat Load sensible heat ratio 0.92 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) DINING ROOM 156 3139 1982 114 102 KITCHEN 130 1257 1711 46 88 HALUSTAIR 94 3415 1131 124 58 ENTRY/LAUNDRY 120 1704 1129 62 58 BATH 3 21 950 692 34 36 BED ROOM 1 195 2848 2506 103 129 BATH 2 45 649 664 24 34 BED ROOM 2 156 2643 2104 96 108 BATH 1 35 630 649 23 33 BED ROOM 3 108 2289 1658 83 85 LIVING ROOM 260 4051 2381 147 123 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Mar-11 12:52:49 wrightsoft Right-Suite®Universal 2012 12.1.01 RSU13148 Page 1 ACCA ...d Settings\Ron Gagne\My Documents\Wrightsoft HVAC\RICPAL12.rup Calc=MJ8 Front Door faces: Page 1