31C ENERGY STAR Qualified Homes, Version 3 (Rev. 06) i u Thermal Enclosure System Rater Checklist Must Builder Rater 5. Air Sealing Correct Verified' Verified NIA 5.1 Penetrations to unconditioned space fully sealed with solid blocking or flashing as needed and gaps sealed with caulk or foam 5.1.1 Duct / flue shaft ❑ ❑ tsf ❑ 5.1.2 Plumbing / piping ❑ ❑ ❑ 5.1.3 Electrical wiring ❑ ❑ ❑ 5.1.4 Bathroom and kitchen exhaust fans ❑ ❑ ❑ 5.1.5 Recessed lighting fixtures adjacent to unconditioned space ICAT labeled and fully gasketed. Also, if in insulated ceiling without attic above, exterior surface of fixture ❑ ❑ ❑ insulated to ? R -10 in CZ 4 and higher to minimize condensation potential. 5.1.6 Light tubes adjacent to unconditioned space include lens separating unconditioned and conditioned space and are fully gasketed 22 ❑ ❑ �' 5.2 Cracks in the building envelope fully sealed 5.2.1 All sill plates adjacent to conditioned space sealed to foundation or sub -floor with caulk, foam, or equivalent material. Foam gasket also placed beneath sill plate if resting atop ❑ ❑ I'd( ❑ concrete or masonry and adjacent to conditioned space 23 5.2.2 At top of walls adjoining unconditioned spaces, continuous top plates or sealed blocking ❑ ❑ ❑ using caulk, foam, or equivalent material 5.2.3 Drywall sealed to top plate at all unconditioned attic / wall interfaces using caulk, foam, drywall adhesive (but not other construction adhesives), or equivalent material. Either ❑ ❑ ❑ apply sealant directly between drywall and top plate or to the seam between the two from the attic above. 5.2.4 Rough opening around windows -& exterior doors sealed with caulk or foam 24 ❑ ❑1 ❑ 5.2.5 Marriage joints between modular home modules at all exterior boundary conditions fully ❑ ❑ ❑ �r sealed with gasket and foam 5.2.6 All seams between Structural Insulated Panels (SIPs) foamed and / or taped per ❑ ❑ ❑ manufacturer's instructions 5.2.7 In multifamily buildings, the gap between the drywall shaft wall (i.e. common wall) and the ❑ ❑ structural framing between units fully sealed at all exterior boundaries 5.3 Other openings 5.3.1 Doors adjacent to unconditioned space (e.g., attics, garages, basements) or ambient conditions gasketed or made substantially air -tight ❑ ❑ ❑ 5.3.2 Attic access panels and drop -down stairs equipped with a durable >_ R -10 insulated cover that is gasketed (i.e., not caulked) to produce continuous air seal when occupant is not ❑ ❑ I ❑ accessing the attic 25 5.3.3 Whole -house fans equipped with a durable ? R -10 insulated cover that is gasketed and either installed on the house side or mechanically operated 25 ❑ ID ❑ Rater Name: .(JSL1 fir Rater Pre - Drywall Inspection Date: O - 1? Rater Initials: Sae-- Rater Name: 30 . VA ezo-Ite r„1� Rater Final Inspection Date: 12.— I O '" Rater Initials: Builder Employee: J Builder Inspection Date: Builder Initials: Notes: 1. At the discretion of the Rater, the builder may verify up to eight items specified in this Checklist. When exercised, the builder's responsibility will be formally acknowledged by the builder signing off on the checklist for the item(s) that they verified. 2. For Prescriptive Path: All windows, doors, and skylights shall meet or exceed ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Version 5.0 as outlined at www.energystar.gov /windows. For Performance Path: All windows, doors and skylights shall meet or exceed the component U- factor and SHGC requirements specified in the 2009 IECC — Table 402.1.1. If no NFRC rating is noted on the window or in product literature (e.g., for site -built fenestration), select the U- factor and SHGC value from Tables 4 and 14, respectively, in 2005 ASHRAE Fundamentals, Chapter 31. Select the highest U- factor and SHGC value among the values listed for the known window characteristics (e.g., frame type, number of panes, glass color, and presence of low -e coating). Note that the U- factor requirement applies to all fenestration while the SHGC only applies to the glazed portion. The following exceptions apply: a. An area - weighted average of fenestration products shall be permitted to satisfy the U- factor requirements; b. An area - weighted average of fenestration products ? 50% glazed shall be permitted to satisfy the SHGC requirements; c. 15 square feet of glazed fenestration per dwelling unit shall be exempt from the U- factor and SHGC requirements, and shall be excluded from area - weighted averages calculated using a) and b), above; d. One side - hinged opaque door assembly up to 24 square feet in area shall be exempt from the U- factor requirements and shall be excluded from area - weighted averages calculated using a) and b), above; e. Fenestration utilized as part of a passive solar design shall be exempt from the U- factor and SHGC requirements, and shall be excluded from area - weighted averages calculated using a) and b), above. Exempt windows shall be facing within 45 degrees of true South and directly coupled to thermal storage mass that has a heat capacity > 20 btu / ft ° F and provided in a ratio of at least 3 sq. ft. per sq. ft. of South facing fenestration. Generally, thermal mass materials will be at least 2 in. thick. Effective for homes permitted starting 11/10/2012 Revised 9/10/2012 Page 4 of 16 I ENERGY STAR Qualified Homes Version 3 (Rev. 06) ,1.-..,----7''''' , . Thermal Enclosure System Rate Checklist Home Address: I V 9 0 LA i T ' City: ! V( 4 lli ,1 State: ) j 1. High-Performance Fenestration Must Builder ff 1 erifie NIA g Correct Verified Verified 1.1 Prescriptive Path: Fenestration shall meet or exceed ENERGY STAR requirements 2 ❑ ❑ ❑ e 1.2 Performance Path: Fenestration shall meet or exceed 2009 IECC requirements 2 ❑ ❑ X ❑ 2. Quality- Installed Insulation 2.1 Ceiling, wall, floor, and slab insulation levels shall comply with one of the following options: 2.1.1 Meet or exceed 2009 IECC levels 3,4,5 OR; ❑ ❑ ` ❑ 2.1.2 Achieve <_ 133% of the total UA resulting from the U- factors in 2009 IECC Table 402.1.3, excluding fenestration and per guidance in Footnote 3d, AND home shall achieve <_ 50% of ❑ ❑ ❑ the infiltration rate in Exhibit 1 of the National Program Requirements 4,5 2.2 All ceiling, wall, floor, and slab insulation shall achieve RESNET- defined Grade I installation or, alternatively, Grade II for surfaces that contain a layer of continuous, air impermeable insulation ❑ ❑ k ❑ >_ R -3 in Climate Zones 1 to 4, ? R -5 in Climate Zones 5 to 8 3. Fully- Aligned Air Barriers 6 At each insulated location noted below, a complete air barrier shall be provided that is fully aligned with the insulation as follows: • At interior or exterior surface of ceilings in Climate Zones 1 -3; at interior surface of ceilings in Climate Zones 4 -8. Also, include barrier at interior edge of attic eave in all climate zones using a wind baffle that extends to the full height of the insulation. Include a baffle in every bay or a tabbed baffle in each bay with a soffit vent that will also prevent wind washing of insulation in adjacent bays • At exterior surface of walls in all climate zones; and also at interior surface of walls for Climate Zones 4 -8 7 • At interior surface of floors in all climate zones, including supports to ensure permanent contact and blocking at exposed edge 6'9 3.1 Walls 70 3.1.1 Walls behind showers and tubs ❑ ❑ .tg ❑ 3.1.2 Walls behind fireplaces ❑ ❑ TX ❑ 3.1.3 Attic knee walls ❑ ❑ ❑ rilr 3.1.4 Skylight shaft walls ❑ ❑ ❑ . 3.1.5 Wall adjoining porch roof ❑ ❑ g ❑ 3.1.6 Staircase walls ❑ ❑ ❑ Zi 3.1.7 Double walls ❑ ❑ 4 ❑ 3.1.8 Garage rim / band joist adjoining conditioned space ❑ ❑ g ❑ 3.1.9 All other exterior walls ❑ ❑ Pt ❑ 3.2 Floors 3.2.1 Floor above garage ❑ ❑ ❑ IX 3.2.2 Cantilevered floor ❑ ❑ I7 2f 3.2.3 Floor above unconditioned basement or unconditioned crawlspace ❑ ❑ ❑ Lei 3.3 Ceilings 10 3.3.1 Dropped ceiling / soffit below unconditioned attic ❑ ❑ ❑ kr 3.3.2 All other ceilings ❑ ❑ '' ❑ 4. Reduced Thermal Bridging 4.1 For insulated ceilings with attic space above (i.e., non - cathedralized), Grade I insulation extends to the inside face of the exterior wall below' at these levels: CZ 1 -5: ? R -21; CZ 6 -8: ? R -3011 ❑ ❑ ❑ 4.2 For slabs on grade in CZ 4 and higher, 100% of slab edge insulated to ? R -5 at the depth ❑ ❑ ❑ X specified by the 2009 IECC and aligned with thermal boundary of the walls 4'5 4.3 Insulation beneath attic platforms (e.g., HVAC platforms, walkways) ? R -21 in CZ 1 -5; >_ R -30 in ❑ ❑ ❑ CZ 6 -8 �J 4.4 Reduced thermal bridging at above -grade walls separating conditioned from unconditioned space (rim / band joists exempted) using one of the following options: 121 4.4.1 Continuous rigid insulation, insulated siding, or combination of the two; ❑ ❑ ❑ r5 R -3 in Climate Zones 1 to 4, ? R -5 in Climate Zones 5 to 8 14'15, OR; 4.4.2 Structural Insulated Panels (SIPs), OR; ❑ ❑ ❑ a 4.4.3 Insulated Concrete Forms (ICFs), OR; ❑ ❑ ❑ 'e< 4.4.4 Double -wall framing 16 , OR; . ❑ ❑ X ❑ _ 4.4.5 Advanced framing, including all of the items below: 4.4.5a All corners insulated ? R -6 to edge 17 , AND;. ❑ ❑ ❑ 4.4.5b All headers above windows & doors insulated 18 , AND; ❑ ❑ ❑ Cr 4.4.5c Framing limited at all windows & doors 19 , AND; ❑ ❑ ❑ tr 4.4.5d All interior / exterior wall intersections insulated to the same R -value as the rest of the ❑ ❑ ❑ exterior wall 20 , AND; 4.4.5e Minimum stud spacing of 16 in. o.c. for 2x4 framing in all Climate Zones and, in Climate ❑ ❑ ❑ �cf Zones 5 through 8, 24 in. o.c. for 2x6 framing 21 �5 Effective for homes permitted starting 11/10/2012 Revised 9/10/2012 Page 3 of 16 / * ENERGY STAR ENERGY STAR VERSION 3 HOME VERIFICATION SUMMARY Date: December 12, 2012 Rating No.: 12 -218 Property: 104 Olander Drive Rating Org.: Center for EcoTechnology Northampton, MA 01060 Rater's Name: Josy Raycroft Builder's Name: Wright Builders Inc. Rater's ID: 8272678 Building Name: 104 Olander -lot 3 Rating Date: 12/10/12 Building Information Ratings Conditioned Area (sq ft): 2248 HERS Index: 45 Conditioned Volume (cubic ft): 26976 HERS Index w/o PV: 45 Insulated Shell Area (sq ft): 5968 HERS Index Target (SAF Adjusted): 72 Number of Bedrooms: 3 HERS Index of Reference Design Home: 72 Housing Type: Single- family detached Size Adjustment Factor: 0.99 Foundation Type: Conditioned basement Building Shell Ceiling w /Attic: ' 5' 4 U= 17 in. ••w/W : Rati•: a 7 Sealed Attic: o = i • Ty. : •' 2 SHGC:0.23 Vaulted Ceiling: o in: • - :lu ■. 0 i Above Grade Walls: R3- IIBL,8- .2 U =0 34 ini •w 1 CC: 0.2;r Found. Walls (Cond) •u• - ior2 "ri +R19 , •.0 n ilt - ion Htg .51 Clg: 651 CFM50 Found. Walls (Uncon. : i• - ct eak- _ - • Out- lie 8.0' FM @ 25 Pascals Frame Floors: , •n- to I uct L-- age: 1 .80 CFM @ 25 Pascals Slab Floors: R15P,R1OU,24W U =0.036 Mechanical Systems Heating: Fuel -fired air distribution, 50.0 kBtuh, 95.0 AFUE. Cooling: Air conditioner, 24.0 kBtuh, 14.5 SEER. Water Heating: Instant water heater, Gas, 0.96 EF. Programmable Thermostat: Heat =Yes; Cool =Yes Ventilation System: Balanced: ERV, 55 cfm, 102.0 watts. Lights and Appliances Percent Interior Lighting: 93.00 Clothes Dryer Fuel: Electric Percent Garage Lighting: 0.00 Clothes Dryer EF: 2.67 Refrigerator (kWh /yr): 555.00 Clothes Washer LER: 281.00 Dishwasher Energy Factor: 0.74 Clothes Washer Capacity: 3.50 Ceiling Fan (cfm/Watt): 210.00 Range /Oven Fuel: Natural gas Note: Where feature level varies in home, the dominant value is shown. This home MEETS OR EXCEEDS the EPA's requirements for an ENERGY STAR Home. HERS Index w/o PV <= HERS Index of Reference Design Home AND HERS Index <= HERS Index Target to comply. REM /Rate - Residential Energy Analysis and Rating Software v13.0 This information does not constitute any warranty of energy cost or savings. © 1985 -2012 Architectural Energy Corporation, Boulder, Colorado. AIR LEAKAGE REPORT Date: December 12, 2012 Rating No.: 12 -218 Building Name: 104 Olander -lot 3 Rating Org.: Center for EcoTechnology Owner's Name: Phone No.: 413 -923 8116 Property: 104 Olander Drive Rater's Name: Josy Raycroft Address: Northampton, MA 01060 Rater's No.: 8272678 Builder's Name: Wright Builders Inc. Weather Site: Northampton, MA Rating Type: confirmed File Name: 12 -218 104 Olander Lot 3 Montague Farmhouse- Rating Date: 12/10/12 Blower door test Whole House Infiltration Heating Cooling Natural ACH: 0.09 0.06 ACH @ 50 Pascals: 1.45 1.45 CFM @ 25 Pascals: 415 415 CFM @ 50 Pascals: 651 651 Eff. Leakage Area: [sq.in] 35.7 35.7 Specific Leakage Area: 0.00011 0.00011 ELA/100 sf shell: [sq.in] 0.60 0.60 Duct Leakage Leakage to Outside Units CFM @ 25 Pascals: 0 CFM25 / CFMfan: 0.0000 CFM25 / CFA: 0.0000 CFM per Std 152: N/A CFM per Std 152 / CFA: N/A CFM @ 50 Pascals: 0 Eff. Leakage Area: [sq.in] 0.00 Thermal Efficiency: N/A Total Duct Leakage Units CFM25 /CFA Total Duct Leakage: 0.0628 Ventilation Mechanical: Balanced Sensible Recovery Eff. ( %): 70.0 Total Recovery Eff. ( %): 69.0 Rate (cfm): 55 Hours /Day: 24.0 Fan Watts: 102.0 Cooling Ventilation: Natural Ventilation ASHRAE 62.2 - 2010 Ventilation Requirements For this home to comply with ASHRAE Standard 62.2 - 2010 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings, a minimum of 52 cfm of mechanical ventilation must be provided continuously, 24 hours per day. Alternatively, an intermittently operating mechanical ventilation system may be used if the ventilation rate is adjusted accordingly. For example, a 105 cfm mechanical ventilation system would need to operate 12 hours per day, as long as the system operates to provide required average ventilation once each hour. REM /Rate - Residential Energy Analysis and Rating Software v13.0 This information does not constitute any warranty of energy cost or savings. © 1985 -2012 Architectural Energy Corporation, Boulder, Colorado. QUICK ANALYSIS REPORT Date: December 12, 2012 Rating No.: 12 -218 Building Name: 104 Olander -lot 3 Rating Org.: Center for EcoTechnology Owner's Name: Phone No.: 413 -923 8116 Property: 104 Olander Drive Rater's Name: Josy Raycroft Address: Northampton, MA 01060 Rater's No.: 8272678 Builder's Name: Wright Builders Inc. Weather Site: Northampton, MA Rating Type: confirmed File Name: 12 -218 104 Olander Lot 3 Montague Farmhouse- Rating Date: 12/10/12 Codes Programs IECC 2012 Performance: Fails EPA ENERGY STAR 2.0 Passes IECC 2009 Performance: Passes EPA ENERGY STAR 2.5 Passes IECC 2006 Performance: Passes EPA ENERGY STAR 3.0 Passes IECC 2004 Performance: Passes Tax Credit Passes IECC 2003 Performance: Passes HERS Index 45 IECC 2001 Performance: Passes IECC 2000 Performance: Passes IECC 1998 Performance: Passes ECC of NY Performance: Fails ECC of NV Performance: Passes MEC 1995 Performance: Passes MEC 1993 Performance: Passes MEC 1992 Performance: Passes ASHRAE 90.2 Performance: Passes REM /Rate - Residential Energy Analysis and Rating Software v13.0 This information does not constitute any warranty of energy cost or savings. © 1985 -2012 Architectural Energy Corporation, Boulder, Colorado. % ; z O C� O h 0 ~ z ,... - ,,,.. rii "` � - O ° m +. 14.. t C) *1„: N T- rm Q, O \ p p g O o N N y W ,. g m o �� • U et TS •.r r CA CV ~ 0.) g 4 > Cl m •E•+ _ E m CU -0 cu O ter" cA N Od PO . CU '71 w a.a ,5 O v 14 w p et z4 o 0., N 0) U V Q MI 11) v °: o • o C.) 1 .4■11 e t O o e ett �� .—� • Ts ° an �y O Q r∎l .a i.a pc) CD • r•4 \\ U :Q, U 4 v) oY — v ,-1 p p o ; Sir rl u O .4 E \ N • 0 °' • V N o o V ti Cr) .�3 cu o� t z w x E o • 1■1 . • u co U� (n vy c 1� L` 3 °u' U u, .p w tt O o Z. ..'•" (1) f: as O� o cn p a t ' .' ;* ft U V V ■ L' • r 0 0w`+"w rp V cu *y a , q #,j s. 7 ' V) O an V iC v "" bG r" bA 1-4 iii + U 'E 0 q � �r s : '' bA .2 '44.•:es„1:4?2,; ' ,4e -k-,,;::+5; ' ',,*.w.,%,,,,,;'''''''14.1','''-'0:',, 44,57-41/41".,;1`,,,,_•-•Z'i'-f--''A.:,..t.,,,4',..t,-..!,14v, - ' AC!'0,$•,4-'1/4`""'-'" ' '' ?A, Tir abe s alter Double Hung NAd—v1ance—d00L2ow85-- 06001 NFRC thi l 11 4...0 : - ,f. : 3 r p5 fi eo na s l inspection: a i e n r s i p e e s E i future e re t n e re n c e ,..v. 11 II Corporati f-t ' Natioria 7 CI .1° „ii,,,f2) Argon T1wr 'o i W 1 G i d 9 a1 E '.t. a cr E NERGY PERFO RA mAN Rat c...a IFIED .21 0 iu.s.ri- el 0 TIN 2 GS 1 Coefficient AD . , U —Fact IP o E r .PLI—e Tra nsm ittance ,.. • D *••''= d for determinin z i NFRC procedures fp ntal conditi ,7,f e N lin ronme fixed set of e not warrant (Metric1S) Solar Heat Gain and ty any w F w R r w C an .p a • trhinfeo_Nili'eFRinC:w:ren:btaisil-,:t-,,ex:;11-w;v.3.3#.nfrc.°:''' .;-.:-•''' ' :'!-:-...--''''''''';' s does 21-3114 ' lates that these rat a s are dete rmined a p .0 .10 7 A L PERFORMANCE i n s nform to aPplicabl I D nd nyi . ,RraoAd produ NannGdcaSdiole(6 6 4 aetarer stipulates nce. NFRC r Mani° product perlorma whole d p V rbo i n S ui 1 b o l f e roadyuc s 1 zeittNf a "Peel" product produ o the suite does e911Psa ilmi cr recomme vn1 ..:^ Or visit the Pella web s V ,•:-V';;;-••:::•"-,•••::•-;°"!•;.l.,:i,=,:,.-..-,• --. .,•-:ii.,,,,,i;,„4,,,i•i,,,i;ei,i,..,",;•<"•:',.:.,..,.,,...-;.:.,,.;„„,„„,...,,,r `, 'tt ,t,JA.,„..-4;,;""--=1.4.z144'44.,:4-,,*:--"if',"-•riz;,t.:11.:•,',13.:4x,;•";';:r-,4".•',""'"-'•--."-.," • ' -,,,, ,‘,,',--', - "'" , ; '• " " „ g.4"..f"..4f'";•.,c:,C,"....r,-,t511„;'.-i-17.--;r-',1.41.!•'.;•.:1'-':'„'=•,'. '''...--•,',-, ' - • - " ' ' ' • ' ' ' •7•1:',Kflt•!-.4f;ST4:e.t-'1717;,,':.•:tfii,"'•':-"-D li:--';''';'•`.."::;'7,7-' ' '" ' , ' " - -• r ,' ." • - '. , - " ; ' , - ''.• , i '''',,i*,,i.:`;',1.;•••:„,i''.•-,',•-s: ''',-':'1.1:`1,,,-,7.;lz::i'",'-;!,"''''•',:" -1 _ - •. •'-, -"•;" , • . ""; , ,; • — - ' " , --,,,,,,;..'i'•'-i-•,-,-'- :-,:',, ' .. ,.--,:z,:. _ ! -",;:::::;,•"..;•;,;.•,', . • - . . ,-;: . .„. '-• "` -- '-'' ' %;•:"..;1,4-•:„, --.:7:,:',.-7r-2...±,.. ,'":',-- ".'"-.' -;'-''' :-."-,- - „.. , --,... . -,... " .-- .—.,._,......- . r '' ' . =,.,■• '''' ' .*. n..,......, _ , , ,..,. ' ' ' ' ..L.r ;''''"1"' ' ' • ,a-:::t."';',;::'.1 ..;- '..C„,.:;:.':.='' ' '..' ' . ' ' , ■ . . . , ' . .01. .- . , ... ..' . . . . - ,` . . , . '4' . ' . 1 , . . ,:. - )14:P.';';:'T..11:14,,,fe '.-r '',':. ' ' ' , , • ' .,` ,.. .'c ''',';. . ' . ' . ,5,. 1,, , . ,, , ... ..., ,,,, , r, , • , . ., ., , ,, . . ' ' ' ' ' 4.' ,. , ''.,, , ..t.. 11 I. ■• . • . ., , ,, ,.., , ,, , ' ' ' ' " '' '''''' ''''''''-' . - . , , . . ■ ., , / . ,L ";:li ''' . , ■ ,....,J+,. • , , 1-1 . .,.., . , • • . t • • • .,,.. . ,. . ... .. . .., ... Z,tEL,;(4:?,"*•`,;',''..,,',Kvi4.,,,t.' ' t, -- ti,lre-Vfr''' o 1)V4r.r:,,Itaa-1,14 " s,- --, 104 OLANDER DR - LOT 3 BEECHWOOD VILLAGE HILL BP -2013 -0009 GIS #: COMMONWEALTH OF MASSACHUSETTS Map:Block: 31C - 039 CITY OF NORTHAMPTON Lot: - PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: New Single Family House , BUILDING PERMIT Permit # BP- 2013 -0009 , Project # JS- 2013 - 000011 Est. Cost: $199949.00 . Fee: $796.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: WRIGHT BUILDERS 84280 Lot Size(so. ft.): 7895.00 Owner: WRIGHT BUILDERS Zoning: PV Applicant: WRIGHT BUILDERS AT: 104 OLANDER DR - LOT 3 BEECHWOOD VILLAGE HILL Applicant Address: Phone: Insurance: 48 Bates St (413) 586 -8287 (116) Workers Compensation NORTHAMPTONMA01060 ISSUED ON: 7/16/2012 0:00:00 TO PERFORM THE FOLLOWING WORK: CONSTRUCT 2 STORY SFH W /ATT GARAGE /PORCHES POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: y Footings: Rough: �� � ' { Rough: �, /c . House # Foundation: # "" i Driveway Final: Final: 1•1 -l 3vl2 J1,..,3, Finalya ... j3_, a ._� �r) -G/ �-- �� � � Rough Frame: Gas: Fire De I artme 1 t / Fireplace /Chimney: t � r�C fi r -- >>,,/// 1(i _ c/ 6 �, Rough: / ..,7 1 /,, Oil• Insulation: l Final: k - �� �� liF Final: /.� -� 3--l2 R.s, Smoke: f v 40 19.-17-0- THIS PERMIT MAY BE REVO , ; :Y HE TY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND ' ,, - U :' a Certificate of Occupancy ' Si#iature: FeeType: Date Paid: Amount: Building 7/16/2012 0:00:00 $796.00 212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272 Louis Hasbrouck — Building Commissioner t