Loading...
17D-080 \ 1 I I I I I I 1 s, :' . '. iii TREATED 2X4 UNDER DOOR - ' ... ••• ... ... ... ■ ■• iii iii iii iii iii iii iii iii iii ... I I I I t I \ ink / 1-- - HE I. \' Mir '' i ii i .:: II AI 01 J •••' 6 INCH STEP -,---, .. ANCHOR LEDGER TO FOUNDATION • /----- ' c •.. r---- GALV. JOIST HANGERS a < ... •.. ..• ... .C. •.• ... ... iii 1 \ , alk /�- --\ / \ NW :11 iii 1 1 11 ' 1. � ` � I 1/2" OSB OVER INSULATION I • � 3/4" ADVANTECH DECKING ; y 1 ••l. •.• ..• ri ... ... ... ••• ... •.. ..• iii RCS •.. NMI UN \ iii / 3 GARFIELD AVE. DETAILS 3 PIONEER VALLEY HABITAT FOR HUMANITY NORTHAMPTON, MA SCALE: 1"=1'-0" Sept. 10, 2012 FRAMING LINE 1 ,/ 4 1' -1 1/2" /2" . \,\ S_ CT / / 1 A ,, z.•.,.-- 30 YEAR ARCHITECT ASPHALT SHINGLES OVER .:: BIT. MEMBRANE TO 3' BEYOND FRAMING LINE OVER i II Mit 5/8" CDX PLYWOOD €€ KM& IIN WIND BAFFLE 1 .1: i :►�_' VENTED HARDI — SOFFIT R -50 CELLULOSE INSULATION ' 1' -2" RAISED —HEEL TRUSS ' 5/4X6 FRIEZE 6" HARDIPLANK FIBER CEMENT SIDING OVER >1111 iii 1" R -5 RIGID INSULATION OVER l 1/2" OSB ON , 2X6 STUDS AT 16" ON CENTER WITH ' I`d's .. DENSE PACK CELLULOSE INSULATION AND lill 1/2" GWB j`. : :: �iS� SE B III FLASHING LET INTO FOAM i i €€ 2X6 RAFTERS i ; = iii LAG LEDGER TO STUDS ' - 2X4 CEILING JOISTS iii iii PLYWOOD CEILING iii iii I: IS IS nii Is: i FURRING: 16 OC � : l I ' 3 GARFIELD AVE. DETAILS 1 PIONEER VALLEY HABITAT FOR HUMANITY NORTHAMPTON, MA SCALE: 1"=1'-- 0" SEPT. 10, 2012 Scale: 1 /4 " =1' -0" C SECTIO\ 3 E D 8/12 pitch L. O 9-- ._, N O -N O TRUSSES TO MATCH N THIS PROFILE 1 — ENGINEERED BY MANUFACTURER = O i T SECT •• .•• J•• d. 4• Q.' Q. �QJ.!...'.! QOJ••••.. L••'.❖.❖••••••• L•..••• oJ�•..til.•••.•❖ 0.•••• L• J•• OJ.❖.❖• •••Q••J••Q••.L ❖QQ.•••• ❖.•Q•:!.� -+ SE ' SECTIO\ 4 � : i�iii••. iii�c���• �� �a�i�a�• ���ia�a����i���aa��••. ���ea�� •���•��e������. j' Q ., A ;" III — L a) SECT a) C I • ! 8/12 pitch O I I SECT -- 1 i E I i TRUSSES TO MATCH i I :•' THIS PROFILE � : :: ENGINEERED BY MANUFACTURER ►. • .., R– 50 FK R -1 { d \ I j rrrrrrrrrrrr• rrrrrrrrrrrrrrrrrr •♦rrrrrrrrrrrr• 1:: I lIl j■■•••" "aiialieViaieViiieliiigileWilaiieWieWieWie% l' IT –5 i I ; 1 I ' — � III I "I" JOISTS — — — :•� _ ;: :• I I ENGINEERED BY MANUFACTURER I • : I `. 11 c.. i 4. � 2X6 X 16 O.C. • Lil •i . •, . ... r • . :�� II" VI ! R -1 0 SECT •:; • • '1' -1 S ECT O R -10 T Q iii W U � W (f) CO III CC) 5 Q P,_! 41! ! !►! !i! ! i ._!! !i! �!�! I, ! ,,i ,; �, _.Ali„,! ,! i . ,- - - , SECT i : i =,ter =�;�; =ar� 111 6' -8" HEADROOM N I1I=1.1I.IM1I i\ 1 - I C - ` - 0 r 1 i' -- SECT 1 I i G i SECTIO\ 1 I I Scale: 1/4"=1'-0" v v !, ! !A! , ! !, y !, !, !it !, !, i ! !, !, ►!, . ! J_ i !, !, !, AL !, !,!,! 0 !, 1.4._ !, SECT - ri H 1 i -I : I 1 1 i 1y � - - - -_ SECTIO\ 2 T Scale: 1/4"=V-0" 3 GARFIEL3 AVE.- Pioneer Valley Habitat for Humanity FLORE\CE, VA Sept. 10, 2012 3 Garfield Avenue Pioneer Valley Habitat for Humanity Florence, MA Sept. 10, 2012 Scale: 1/4"=1'—o" RIGHT ELEVATIO\ 30 "x48" 30 "x48" 30 "x42" 3 30 "x48" 0 "x48" Th T 1 7 - --II L c � j c 3 Garfield Avenue Pioneer Valley Habitat for Humanity Florence, MA Sept. 10, 2012 Scale: 1/4"=1'—o" LEFT ELEVATION 36 "x60" 36 "x60" 36 "x60" i I 30 "x48" 30 "x48" 30 "x48" 30 "x48" 36 "x60' I I I I I �1 Hll I I I I I I I I I I 1 c — L L J- J v 0 LEGEND: '" THERMOSTAT I CABLE TV TELEPHONE +4 DUPLEX RECPT. OVERHEAD LIGHT 0 S O FAN db 0 - NOTE: THE ELECTRICAL PLANS ARE SCHEMATIC IN NATURE. THEY REPRESENT THE MINIMUM REQUIREMENTS OF THE OWNER. THE 0 CONTRACTOR IS RESPONSIBLE FOR MEETING ALL CODE REQUIREMENTS AND THE INSTALLATION OF ALL DEVICES SPECIFIED IN THE TECHNICAL SPECIFICATIONS. O SMOKE ■ .-/'\ /\ S S l n :I t L n 0 ' � 1 CO I -S n u ti . n I 1 I I 5S I1 i y ® 'i - ce -- .lii 1 , - .A: - L _ �p :, ` 0 ; i i---i�� :i ^ , iii 1 W,3) -p `_ �``._ ® ■ \ , . L�_ „..:__..,J[ O/ : SSS , ' - ``,, +Q e S -- - I I ; I O 11: ll 0 SMOKE 9 S5 ._-,2a'Y__,, ui� p ' \1 � -Q-'r--- 4 4 I' gy \ _ _ _ _ D y y \ C ; ,' ,, p 0 �5 ii N „ / iii 11 1' S II - � -} --..1L N� s� s� 3S N w ef i $ �.) E _ W w ` 1 m SMOKE — S SMOKE S 0 O _ O O ',........__ ......„7 9 IM fl c s • i s db © o$ db 1 00 CO SMOKE SMOKE — ■ O PANEL S S� /\ —= , METER 1I _ _ E. p 3S5 I 1 + 1 T 1 I o O SECOND FLOOR FIRST FLOOR 3 GARFIELD AVENUE ELECTRIC PLAN Pioneer Valley Habitat for Humanity FLORENCE, MA Sept. 10, 2012 2 -2x10 n J L_1 SHED (ENCLOSED) o co 2 -2x10 • trtd 5 O Q cL �II 2x6 trtd L� CL CD PORCH v ra LL 2 -2x10 -- trtd a E L_ 0 - N a - 0 N 0 = 0 N ; + I —joist type, size and spacing — -, � by manufacturer (i) Q) I o ' a_ rigid insulation bearing wall under between band joists CD 0 a � 3'-2" SECOND FLOOR CD (1ST FLOOR CONCRETE) Q) o � Q Q) 4) 0 hr) L_ iiiit //--- \ I I I I I I I a •■. s, : :.:'. ,... • TREATED 2X4 UNDER DOOR ..• ••• ... ••• ••• ... ... ... ••• ••• ••• •• ... ... ... ••• ••• ••• ••• I I I I I I \ / alk / I I: \ i NIF I I cc iii `P • ' 6 INCH STEP . — } ;;; / ANCHOR LEDGER TO FOUNDATION ` ' c ••• GALV. JOIST HANGERS ... ••• •.. ... MINI .. ••• ••• ... "' ••• \ al // .'.- --- 2:: 411. Hi - W ` : . E . . ` . I iii 1/2" OSB OVER INSULATION I �I . . 3/4" ADVANTECH DECKING ... ... 1.-_ •e. ••• ... ••• ••• �. • ... ... •.. ... \ iii \�_ . 3 GARFIELD AVE. DETAILS 3 PIONEER VALLEY HABITAT FOR HUMANITY NORTHAMPTON, MA SCALE: 1"- ' -0" Sept. 10, 2012 SECT I' �� l C I . .■ 2X10 INSULATED HEADER . II"' DRIP CAP LET INTO INSUL. ' iiiii ,g IMO 5/4X4 EXTERIOR CASING i --,.1::: :WIZ Isr. �? I I I I I I I I I 1 I I � I I 1 -- - I 1 / / � I I SECT ' 0 I I wr �� -11'� r D 1 II 1 IEEE . . I I 1 I I I P111 •. I I I WOOD SILL P` :. � i i r ' ' 5/4X4 EXT. CASING I �� I \ 3 1/2" COLONIAL BASE fin: 2 3/4" "ADVANTECH" FLOOR 1 ME BAND JOIST 1 ' eg g .. I 1 . I pli . I � � 1 1 •. I I _A, 1 iii, _.... TREATED 2X6 MUDSILL ON 1 CLOSED CELL SILL SEAL q _ ANCHOR BOLTS AT 6' MAX O.C. _ ' 8" CONCRETE FOUNDATION I 'tili 2" R -10 RIGID INSULATION 1 I • EH .. .. • • ■. ••• •::: / (E--E-1 r><1 ;\ 1 I E_ HALF WALL WITH WOOD CAP 2 1/2" COL. CASING I 1 0 1 1 ' rte) I I NOTCH STUDS OVER BAND JOIST 1 I AND ATTACH TO JOISTS I 1 i 1 i 1 I 1 I \ 1 I I I I 1 I 1 I I 3 GARFIELD AVE. DETAILS 2 PIONEER VALLEY HABITAT FOR HUMANITY NORTHAMPTON, MA SCALE: 1"="1'.--0" Sept. 10, 2012 k Scale: 1 /4 " =1' —O" Scale: 1 /4 " =1' —O" > ` F \ T ELEVATIO\ REAR = LEVATION 0 E . L_ O 8/12 itch -4-J N 8/12 pitch P 0 r 1 0 16 N 0 = c O + % O Q 2> N u) O _ - N c O 11 24 "x36" 30 "x54" 30 "x54" 30 "x48" .7 \ / 1 I I 30 "x42" 28 "x36" 36 "x48" 36 "x48" o CSMNT L.- L � , . 1 n , Kitchen Window f - - - - - E 1 1 > < Q I I I I > 1 I I 1 I I I - I r 1 I I I I 1 1 1 1 I I I 1 L_- U I 1 1 I I 1 1 1 1 1 I 1 1 1 - Q= 1 I 1 1 1 11 I 1 1 I 1 1 1 0 CD 1 1 I I I I I I 1 1 1 1 1 I 1 1 1 0 .-- L L J L -- __ — I L LL y - l - C � — _) J N) LL ) l c —� L — C'' m n A m C1 6' -O" t 9' -4" I 14 5' -4" 1' 9' -61 /2" n D n 9' -3" 2' -2' 9' - 3' 1. O i co F rt --- O I o -' N- O \ 7 2' -5 1 /2" O I 1 r f D W / - 101 r _ O I A m D D. D O / O I I FRAME TO 36 ABOVE FINISH FLOOR 2 °, — ,_ r> O IF- o 0 u, CA r Ca I / B J BI Er - — J We Mai 5' -10" 8' -0" MEM 3 Garfielc Avenue Pioneer valley Habitat for Humanity SECO \3 FLOOR PLAN Florence, MA Sept. 10, 2012 Scale: 1/4"=1'— 0" N C'') m --I A m n \ i N. - N. r 6' -6 1/2" 6' -7" 6' -9 3/4" I 0 w I up I N 6 - 10 " N elect. conduit / 4'- °" SECT r\) / / / o O_: r-.) 2 I . I' 0 x a o x' W El 6 O O 2 -1 I 7 / O ,p s 8' -10 1/2" 12' -8" 0 . I I G� I D — - - - t m 0 ) - \ — A u I N 13 —0 m � I ' SECT CO O / \ ., �/ Fs'. : 21 0" 1 / g _ \ / q / N A N III CITY OF NORTHAMPTO BUILDING DEPARTMENT - These plans have been reviewed 4' -6" And approved. /�e du c,�da g`'l? " UNDERGROUND ELECTRIC SERVICE Date / °.----1.--7-- • _ - _ 3 Gi 3 Garfie c Avenue Pioneer Valley Habitat for Humanity FO, \RATIO\ PLA\ FI orl Florence, V A Sept. 10, 2012 Scale: 1/4"=V-0" ,... \ \ w6 t4' 1 'ir \ 1 H 04440 1" 1 i N VVY 1 1 i • i Pk 11 I .„-----„,. gril 1 , , ,. - ,.:., , i CI ,, . • °,,)%'‘' ..,,, , 1 1 11 ; , .. .„ .. 40 , 1. __It , , i I i r,,,,t*A..z , - =1 1 1 4,4 4Y,erii F,,,:1$1V41 11 . ?.tiNrl --------- , ,,,Lit,'" f --_-.....„-- ,, -- , ‘' 4 1.---, --,n-__,------- t ' -- , ,1 • f it I _.... _ — - - ,z4,-.. ' 1 1 4 ' i 4460, j .f i i i ii 1 I VOW_ 1 0 a i 71 i 14% t t 1 , ; kv.i. I [ c.,,o'v 4,71L i , 9:1; , 1 ,,,,, 1 .444.,,,,,,:.. 3 .. t t c i ! . ph 1. i. \ _ ..t. • t t tit:„Wtt. t.:t t ' Ca I \ ,y,?,:,,,,-0,. . . ... . . , :i.-,411,t4- ' VIC i I • - ' - " , 141 i SU , ,ogrO ' U. - , • * , 2,AV . , 1 ..„.„ .,. < , i 0 • •:, I i . . ,, - . , !41;': I i L i vIA':5g5A. . „.„ \ 1 Jim I t , !Rgi 1 , ;. ,, =•.1 ..„-0,' -,,,,,,,,e 1 t -- - i 1 . , $....._ , . . . ..,,,,,,,,,,,,, , „..,,,, , f I t • _.. ,. . ____,.......,.. ,.....,..._ , __ iss_ttem____ .. ....... i . ? —______, i 1 , .,.9‘- t ' F t t ' „i4n.: ! 1 ,,,,-*,,,,, ti t t t ,., , .,,,, ',Aig i Vh.41 , , „„....... i .,. v .,„ ; - 1.1*.t1 t I . ' , ,t-s- , i ..„ -.:4 ..t v e LI ' 1 AAA; f f "If 1 ei , l rt i 9 6 , - I 11 .• ,..,,,,,,,,,,,,,:‘,...„ 1. ) L---,----- : f 1 ' ' 4 : 04 K , 4,01. 4 •MsgA'W 4 4 , N • . At(4';;Iiii.ogiV k" frit49L- i i=0 m ,------tt .... % Vi' ',- „.„,,,,: f4.Y., ‘ 1 ,,, , •,,: S, ..,,,,,,,`: --,.,•,,,,,,,,..,,,, ... , '.. ,,,,,, ,S*4. ,, ". ,,, , ,, , ,,,, ' ''''' . . - .... ■Iti % VV:4%:, y.1 .",V1WVits"--,V..,44.,°. . , ... ro,uott,lempoireg4tiV 7 "0.74.- t '''% i . , 1 \ W i /-"*",- \ i -,wor i .,/ . ) - -, 1 , . , _„----• . , 1 . .., 7 °A" • - '' ,f ';','Wt,O= %., - /1/7 n / ..z.--1 . .., / / ,, ,, / ., , . , , .. , . ,. tA*, ----- „ „e , ,.., Pi Permit No. D13 -13 Conditions: Driveway Permit In lieu of plan approved by the City Engineer I agree to the following added conditions: 1. I will contact the Department of Public Works and have an inspector check and approve the graded gravel base prior to paving to insure compliance with slope and location; 2. I further agree that if in the inspections, any of the permit conditions are not met that I will at no expense to the City remove and replace the driveway as directed by the City Engineer. BY: 41.1.A I. etition _ Signature Name: MJ Adams/Director of Habitat Address: 140 Pine Street, Florence, MA 01062 413 -586 -5430 Note: The Public Works Department recommends that you provide a plan showing the proposed driveway with grades and location in the future to avoid possible expense which you will incur by not getting approval of actual plans in advance. For Commercial and Industrial applicants, a plan showing the proposed driveway with grades, location and Planning Board permits are required. Cc: Building Inspector • .. .;1 RECEIVE i -- Permit No. D13 -13 CITY OF NORTHAMPTON, MA OCT :3 DRIVEWAY PERMIT DEPT. OF BUILDING INSPECTIONS NORTHAMPTON, MA 01060 Date: 10/15/12 Check #: 664y FEE: $250.00 THE BOARD OF PUBLIC WORKS Driveway must be staked and house & lot number posted The undersigned respectfully petitions your honorable body for: A new driveway Permission to install a driveway at: 3 Garfield Avenue, Habitat for Humanity Fifteen (15) foot maximum width at the street line. Gutter drainage not to be disturbed. All Drainage shall be directed off the driveway surface to adjacent land and not on the existing Roadway. Driveway surface to be paved as soon as possible if the grade of the proposed Driveway exceeds 3% or more. Homeowners will be held responsible for any cost to the City of Northampton in the event of a washout of this driveway. Code of Ordinances §350 -8 8 providing standards for private, individual driveways as amended by the City Council on October 15, 2009, must be followed. By: MJ Adams, Director of Habitat for Humanity Telephone: & 413- 586 -5430 Si ature: + ��. va, � �� �6 Proposed Location Inspection By: f - • �/ cnlc; . / Gravel Base Grade Inspected By: Final Approval: THE BOARD OF PUBLIC WORKS voted that petition be granted. S a ( 3 Edward S. Huntley, P.E. Director of Public Works Wa -1 3 Cc: Building Inspector (SUBJECT TO ATTACHED CONDITIONS 1 & 2) L' 'J c. A signed copy of the Thermal Bypass Checklist. d. Energy information including mechanical equipment posted on the electric panel. e. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy Star Windows and the Thermal Bypass Checklist. Duct blast testing when practicable. 30. Vapor retarders. Although these are still in the code have exceptions, one must understand that there is a difference between a vapor retarder or barrier and an air barrier. An air barrier is intended to stop air flow (convection) a vapor retarder or barrier is intended to stop molecular moisture transfer (diffusion). A vapor retarder or barrier is effective even if there are some holes or gaps, however an air barrier has to be absolute and complete. If air can leak through an electrical device or through a crack it follows the path of least resistance and carries 99% of the moisture in a structure. This is evident every time one • exposes fiberglass insulation and finds black insulation, which is dirt filter out of the air moving through the insulation. 780 CMR R601.2 for vapor retarders and Table N1102.4.2 for air sealing requirements. 31. Unvented attic assemblies. Hot roofs are allowed, but have specific requirements 780 CMR R806.4. 32. Deck ledgers and post must be appropriately attached, bolts or lags. 780 CMR R502.2.2.1 Note: ThruLoks are engineered for post attachment supporting a railing. 33. Smoke and CO detectors as required. 780 CMR R314 and R315. 34. Closets beneath stair which have doors must be drywalled with %2 ". 780 CMR R302.7 35. If there is mechanical equipment or a combustible roof, 30 sqft of space, and 30" measured from top of ceiling joist to bottom of rafters an attic access of minimum RO of 22" x 30" is required to be located in an accessible place. It must be insulated, gasketed, and secured in place. 780 CMR R807 Relevant items must be submitted to the building department for approvals before inspections and or CO can be signed. Other items are intended to avoid costly issues at inspections. Feel free to call if you have any questions. My telephone number is 587 -1240 and office hours are Monday through Friday, 8:30 am to 4:30 pm, excepting we close for walk -ins at 12:00 noon on Wednesdays. My email address is: cmiller Thank you for your cooperafon on these matters. Chuck Miller City of Northampton Assistant Commissioner and Zoning Enforcement 14. A braced wall plan identifying appropriate braced wall areas and braced wall method being used. 780 CMR 602.10. a. Garage corners and large corner window /door layout may require special solutions. b. All corners must be appropriately attached to the foundation. 15. Ceiling heights minimum 7' for habitable spaces, 6'8" for bathrooms includes tub /shower area if a shower head is used, 6'8" for basements, 6'4" at beams /ducts. 780 CMR R305.1. MA amended 16. Hazardous glazing locations, within 24" of a door, or within 60" of a stair, or across from hot tubs, spas, bathtubs within 60" if not 60" above the walking surface, and other locations. 780 CMR R308.4 17. Windows over 72" above grade with the opening Tess than 24" above the finished floor shall meet the 4" sphere rule. Order restrictors! 780 CMR R612.2 18. Egress and emergency•escape requirements shall be strictly met. a. Basements, habitable attics, and all sleeping rooms require emergency escape. 780 CMR R310 b. Windows within 44" of floor and 5.7 sqft, Casements 20 "x41" exceptions - DH 3.3 sqft min, window size 5 sqft at 1s floor. Minimum clear opening 20 "x24" or 24 "x20 ". 780 CMR R310.1.1 c. Two doors remote as possible at the normal level of travel, opening measured from the face of the slab to the stop with door at 90 degrees, one 32" and one 28" minimum 78" high. 780 CMR R311.2 d. Landing at each door 36" out and the width of the door minimum 36 ", maximum step 7 %" from the top of the threshold and only in- swinging doors. 780 CMR R311.3 19. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9 ", maximum riser 8 % ", maximum overall variance for the run is 3/8 ", 4" sphere rule on risers except where the total rise is 30" or less 780 CMR R311.7.4.3 Exception, 4 3/8" on balustrade, 6" in the triangle. Graspable rail 13/4" minimum and 2" maximum rail, height minimum 34" maximum 38 ", required for 4 or more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling height from nosing. 780 CMR R311.7. 20. Guards 36" minimum height above walking surface, a bench is a walking surface, required for more than 30" above floor or grade within 36 ", 4" sphere rule. 780 CMR R312.1. 21. Educate the plumber and electrician about maximum notch and hole sizes, and placement. 780 CMR R502.8 and R602.6. In bearing studs holes not larger than 40% of a stud no closer than 5/8 to the edge, In interior non - bearing studs holes not larger than 60% of a stud no closer than 5/8 to the edge, in bearing walls if more than 50% of a plate is cut or notched a 1 %2" 16ga. strap must extend a minimum of 6" past the cut both directions and be nailed with 8 -10d per side, or holes in joist are a maximum 1/3 the depth not closer than 2" from the top or bottom. Notches are different. 22. Dryer duct transition is limited to 8' of aluminum flex and must be exposed. 780 CMR M1502.4.3 23. Dryer duct maximum equivalent length is 25' or per manufacturer's specs. 780 CMR M1502.4.4.1, no screwed connections. 24. Markup air is required for any exhaust hood of 400 CFM or more. 780 CMR M1503.4 25. Fireplaces require all combustion air be provided from the exterior and below the firebox, duct work maintaining 1" clearance for 5' from the duct outlet for all fireplaces 26. Fire and draft stopping shall be completed before rough inspection. 780 CMR R302. 27. Ignition barriers in place before final. 780 CMR R316. 28. Dwelling /Garage fire separation. An attached garage (within 3' of main structure) is required to have %2" drywall on the garage side of the separation wall and if there is a finished space above the garage all walls must have %2" drywall and the ceiling 5/8" drywall. 780 CMR R302.6 29. Energy aspects shall comply with the stretch energy code. 780 CMR Appendix 115AA or 2009 IECC. a. An initial HERS evaluation is required including insulation levels anticipated. b. A final HERS evaluation confirming code requirements have been met including duct testing. City of Northampton , Massachusetts DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street • Municipal Building Northampton, MA 01060 • INSPECTOR Pioneer Valley Habitat For Humanity Larry Sawula October 18, 2012 PO Box 60642 Florence, MA 01062 Subject Location: 3 Garfield Avenue Lot #3 Map Block: 17D - 080 Mr. Sawula, Your plans last dated 09 -10 -12 have been approved as noted and per memo. Please follow up on the following items: 1. Final HERS Rating and signed TBC is required before CO is issued. 2. Smoke and CO detectors are required within 10 feet of a bedroom door and at each level. I suggest a heat detector in the storage room, but it is not required. 3. Windows 72" AFG with the opening within 24" FF require a restrictor to meet the 4" sphere rule. 4. Please review the items below as some may apply to this project. As of August 4 2011 the 8 Edition MA code is the 2009 IRC with MA amendments. In the following are some generic requirements which seem to be problematic. This is not intended to be comprehensive, nor is it a substitute for purchasing and reading the MA codes. 1. Structures shall conform to 780 CMR 8 Edition 1 and 2 family building codes with MA amendments. 2. Grading plan for structures being constructed required. 780 CMR R401.3 for drainage requirements. 3. A basement drainage system is required in all basements 780 CMR R405.2.3. except those in group I soils (table R405.1) 4. Foundations that retain earth and enclose interior space require damp proofing 780 CMR R406.1. 5. Through wall form ties must be removed from both faces and patched with hydraulic cement. 780 CMR R406.2 of amendments. 6. Foundation anchor bolts must be Y2 and be embedded a minimum of 7" into the concrete. 10" bolts! 780 CMR R403.1.6 7. CMU foundations require 3/8" parging before damp proofing. 780 CMR R406.1 see exceptions. 8. Emergency escape is required out of every basement whether habitable or not. 780 CMR R310.1 9. Ceiling joist are intended to prevent spread, once raised above the wall plate they become rafters ties and may require up sizing of rafters and increased nailing for example with a 4" slope 8 -16nd common are required at each connection. 780 CMR R802.3.1. When there is neither of these a structural ridge is required with a load path to the foundation. 10. Steel straps over the ridge or 1x4 minimum collar ties are required 4' OC in the upper 1 / 3rd 780 CMR R802.3.1 11. Ridge boards must be the full depth of the cut. 780 CMR R802.3. 12. A complete window and header schedule is required. 780 CMR Table R502.5 for header sizing and number of jack studs required. 13. All framing materials which are not code prescriptive must have stamped engineering. a. LVLs b. I -joist and or Floor Truss c. Roof truss MUNICIPAL SEWER/ AVAILABILITY APPLICATION Northampton Streets Department 125 Locust Street Northampton, MA 01060 587 -1570 A Department of Public Works Trench Permit and Sewer Entry Permit shall be required prior to any construction or connection activity associated with this application. Location: # 3 Garfield Ave, Habitat for Humanity Inquiry Made By: MJ Adams, Director 586 -5430 Date of Inquiry: 10/11/12 Reason for Enter into City Sewer System Request: Municipal Sewer Main in Front of Location: Yes X No Municipal Storm Drain Available: 5'/2 deep Yes No Size of Sewer Main: e `( Material: C I ) : V .0 Age: Depth of Sewer Main: R EO Size of Service Connection: /VOA/6 Type of Service Connection: Tie -in to Sanitary Main Tie -in to Sanitary Stub 5< Comments: e t VA Note: If this availibilitv is for new construction. this form must be hand delivered to Building Inspector. A corresponding "sewer entrance fee" shall be paid prior to making any connection to the municipal sewer system. Arrangements of such installation shall be made with the Northampton Streets Department with a minimum of 5 working days notification. All work shall conform to Northampton Streets Department specifications. � Joh n Hall 4° Sewer Department cc: Ned Huntley, Director DPW Louis Hasbrouck, Building Commissioner 1� 13 -3 MUNICIPAL WATER AVAILABILITY APPLICATION Northampton Water Department 237 Prospect St. Northampton, MA 01060 587 -1097 A Department of Public Works Trench Permit shall be required prior to any construction or connection activity associated with this application. Location: #3 Garfield Avenue, Habitat for Humanity Inquiry Made By: MJ Adams Director 586 -5430 Date of Inquiry: 10/11/12 Number of Type of Single Family X Type of Private X Units: 1 Unit(s): Apart. Comm. Ownership: Condo Multi- family Rental (Annlicant to fill out the above) Municipal Water Main in Existing service to Front of Location? Yes: X No: site? Yes: X No Size of Water Main: 8" Material: Ductile Iron Age: 2004 Approximate Static Street Flow Test Conducted: Yes: No: X Pressure: 55 psi If done attach results Size of Service Connection 1" Suggested Meter Size: 5/8" Comments: The Water Department cannot guarantee adequate water pressure during peak demand times at elevations above 320 feet. • A corresponding water entrance fee shall be paid prior to making any connection to the municipal water system. • Arrangements of such install. n shall be made with the Northampton Water Department with a minimum rking days notif , . ' n. All w k shall - 'o • • to . orthampton Water Department specifications. • / C David W. Sparks, Superintenden of Water Dept. Water Entry $200.00 Meter $100.00 Radio $100.00 cc: Ned Huntley, Director cc: Louis Hasbrouck, Building Commissioner Note: If this availability is for a new construction, it must be hand delivered to the Building 1� / Inspector. l�" sttti) I admit) ',Pants ..Water Application Wtmtt A‘ -Aloe 1 )3 —t3 Information and Instructions Massachusetts General Laws chapter 152 requires all employers to provide workers' compensation for their employees. ' Pursuant to this statute, an employee is defined as "...every person in the service of another under any contract of hire, express or implied, oral or written." An employer is defined as "an individual, partnership, association, corporation or other legal entity, or any two or more of the foregoing engaged in a joint enterprise, and including the legal representatives of a deceased employer, or the receiver or trustee of an individual, partnership, association or other legal entity, employing employees. However the owner of a dwelling house having not more than three apartments and who resides therein, or the occupant of the dwelling house of another who employs persons to do maintenance, construction or repair work on such dwelling house or on the grounds or building appurtenant thereto shall not because of such employment be deemed to be an employer." MGL chapter 152, §25C(6) also states that "every state or local licensing agency shall withhold the issuance or renewal of a license or permit to operate a business or to construct buildings in the commonwealth for any applicant who has not produced acceptable evidence of compliance with the insurance coverage required." Additionally, MGL chapter 152, §25C(7) states "Neither the commonwealth nor any of its political subdivisions shall enter into any contract for the perfoiivance of public work until acceptable evidence of wit e insurance requirements of this chapter have been presented to the contracting authority." Applicants Please fill out the workers' compensation affidavit completely, by checking the boxes that apply to your situation and, if necessary, supply sub - contractor(s) name(s), address(es) and phone number(s) along with their certificate(s) of insurance. Limited Liability Companies (LLC) or Limited Liability Partnerships (LLP) with no employees other than the members or partners, are not required to carry workers' compensation insurance. If an LLC or LLP does have employees, a policy is required. Be advised that this affidavit may be submitted to the Department of Industrial Accidents for confirmation of insurance coverage. Also be sure to sign and date the affidavit. The affidavit should be returned to the city or town that the application for the peiniit or license is being requested, not the Department of Industrial Accidents. Should you have any questions regarding the law or if you are required to obtain a workers' compensation policy, please call the Department at the number listed below. Self - insured companies should enter their self- insurance license number on the appropriate line. City or Town Officials Please be sure that the affidavit is complete and printed legibly. The Department has provided a space at the bottom of the affidavit for you to fill out in the event the Office of Investigations has to contact you regarding the applicant. Please be sure to fill in the permit /license number which will be used as a reference number. In addition, an applicant that must submit multiple permit/license applications in any given year, need only submit one affidavit indicating current policy information (if necessary) and under "Job Site Address" the applicant should write "all locations in (city or town)." A copy of the affidavit that has been officially stamped or marked by the city or town may be provided to the applicant as proof that a valid affidavit is on file for future permits or licenses. A new affidavit must be filled out each year. Where a home owner or citizen is obtaining a license or permit not related to any business or commercial venture (i.e. a dog license or permit to burn leaves etc.) said person is NOT required to complete this affidavit. The Office of Investigations would like to thank you in advance for your cooperation and should you have any questions, please do not hesitate to give us a call. The Department's address, telephone and fax number: The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations 1 Congress Street, Suite 100 Boston, MA 02114 -2017 Tel. # 617 -727 -4900 ext 406 or 1- 877 - MASSAFE Fax # 617- 727 -7749 Revised 7 -2010 • , www.mass.gov /dia The Commonwealth of Massachusetts Print Form Department of Industrial Accidents Office of Investigations 1 Congress Street, Suite 100 Boston, MA 02114 -2017 www.mass.gov /dia Workers' Compensation Insurance Affidavit: Builders /Contractors /Electricians /Plumbers Applicant Information Please Print Le • ibly Name ( Business /Organization/Individual): ( 1' A [i at VWL IA-( Address: ( t'i nQ J ' 6 ( c + Y i4 4 d ) Q 6 2 City /State /Zip: avo e Phone #: 4 1/3 - - 7-26 Are you an employer? Check the appropriate box: Type of project (required): 1.1 I am a employer with 4. I am a general contractor and I �/ employees (full and /or part-time).* - have hired the sub-contractors __ - - N I New construction 2. t I I am a sole proprietor or partner- listed on the attached sheet. 7. Remodeling ship and have no employees These sub - contractors have 8. 1 I Demolition working for me in any capacity. employees and have workers' g n Building addition [No workers' comp. insurance comp. insurance.$ required.] 5. We are a corporation and its 10.n Electrical repairs or additions 3. ❑ I am a homeowner doing all work officers have exercised their 11.n Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.n Roof repairs insurance required.] t c. 152, §1(4), and we have no p ]..- (-0` � (vj 5Uv e [No workers' 13. U Other C 1>e v — � v 1 0 , comp. insurance required.] *Any applicant that checks box #1 must also fill out the section below showing their workers' compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. Contractors that check this box must attached an additional sheet showing the name of the sub - contractors and state whether or not those entities have employees. If the sub - contractors have employees, they must provide their workers' comp. policy number. I am an employer that is providing workers' compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Policy # or Self -ins. Lic. #: Expiration Date: Job Site Address: City /State /Zip: Attach a copy of the workers' compensation policy declaration page (showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one -year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the D - or insurance coverage verification. I do hereby : rf y de j t ti e pains and penalties o f perjury that the information provided above is true and correct Signature: ' l rims Phone #: 3 7 6) Official use only. Do not write in this area, to be completed by city or town official II City or Town: Permit/License # Issuing Authority (circle one): = L Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6. Other - Contact Person: • Phone #: ENERGY EFFICIENCY PLAN 2. Preliminary Home Energy Rating Results Based on the assumptions described above, we have calculated the following Preliminary Home Energy Rating results. Preliminary HERS Index: 60 Preliminary Improvement Over 2011. -40 Massachusetts Reference Home: 34.9% ENERGY STAR HERS Index Target: N/A Note that Confirmed Home Energy Rating results may vary from the Preliminary Home Energy Rating results due to changes in building plans, energy features installed in the home, RESNET standards, software changes, and other factors. 3. Services Requested CET will provide a Confirmed Home Energy Rating for the purpose(s) indicated below. CET will charge fees for these activities based on the Price List attached to your Horne Energy Rating Services Agreement. ® Stretch Energy Code compliance lEl Utility company incentives for the Massachusetts New Homes with ENERGY STAR program — Tier 1 or li 0 Utility company incentives for the Massachusetts New Homes with ENERGY STAR program — Tier 111 ENERGY STAR version 3 certification As part of these services, CET will verify that your home meets all the requirements listed in the attached Program Description. I have reviewed and understand this Energy Efficiency Plan. I have reviewed the assumptions in part 1 and confirm that the assumptions are correct. Stonature: � A Date; I i t t Printed Name: M "—— t 1 Compart;Ciarcit \f V \ r t ) CET Internal Use Only HERS Rater: John Saveson Date of Preliminary Rating: 9/17/12 REM/Rate File Name: 12- 3963Garfield Ave Florence plans.blg Form v2012 -02-13 Page 2 of 2 - Please send signed torte to the Center for EcoTechnology Tel (413) 58 &7354 ext.242 -- Fax (413) 586 -7351 - rreenhclmetn' eetonline erg CFNIER ..'. " EcoTechnology we make green make fen ENERGY EFFICIENCY PLAN Project Address: 3 Garfield Ave, Florence, MA 01062 Conditioned Floor Area 1480 Building Type Single Family Residence Bedrooms 4 I. Assumptions for Preliminary Home Energy Rating CET has completed a Preliminary Home Energy Rating with the following assumptions: a) The construction plans you have provided are accurate, including window dimensions and locations. b) Energy features not listed below in part c will meet the prescriptive requirements of the IECC 2009. c) The home will be built to incorporate the following energy features: Bbl ldin E4wet01)0, Specifications Used in Analysis Basement Condition Slab on Grade Foundation Wall Insulation Type = 2" Interior Rigid Foam Board R- Value= 10 Slab Edge &Under Insulation Type = 2 " Rigid Foam Board R- Value= 10 Rim & Band Joist Insulation Type = Cell + Rigid Foam R- Value= 19 + 5 Above Grade & Walkout Walls Insulation Type = Cell + Rigid Foam R- Value= 19 + 5 Grade =2 Windows U -value = .30 SHGC Glass Doors U- value = N/A SHGC = N/A Skylights U -value = N/A SHGC= N/A Exterior Exteriorpoors R -5 (opaque areas) Ceilings Insulation Type = Loose -blown 13.5" Cell R- Value= 50 Blower Door Test* 5.0 ACHSO or better* Thermal Enclosure Checklist Sections 3 5 Meet ALL Checklist Requirements as verified by a HERS rater at pre - drywall and final inspection • The 2009 IECC requires a blower door test result of 7 ACHSO or tower. The number listed here requires significant improvements in air sealing beyond the base energy code. Mechanical Systems Specifications Used in Analysis Heating Equipment Type: Propane Boiler Efficiency: 91 AFUE Cooling Equipment Type: N/A Efficiency: N/A Water Heating Equipment Type: On- Demand Propane Efficiency: .82+ EF Duct Leakage N/A or less leakage to the outside at final inspection Duct Location N/A Whole House Ventilation (ASHRAE 62.2) Exhaust -only, with programmable timer + /or speed controls Liahtina &- Appliances Specifications Used in Analysis Lighting 80% or more compact fluorescent bulbs Refrigerator Energy Star Cerfied Dishwasher Energy Star Certified Page 1 of 2 • zxnM ?a', -- � ` ., i # _ �a=sar asetig ` • ' �cup.f��:•.y� Ao - DEPARTMENT Or BUILDING -INSPECTIONS • ...... - .: 212 Main Street ® .Municipal B uilding ; INSPECTOR Northampton, M4 01060 IMP LOCATION • J4 15 4 -12-AQ 71/- ' - . SQUAB a . TAGE AMOUNT t o .. . BASEMENT @ _ 20 • • �- j . • • . • • & • 1 FLOOR @ .50 217D@30 . . . / 'd / - . Yz FLOORS, F,r-NISH ATTIC, GARAGE @ 20 1(0 • - . * . . • • . J / . ) 4 . • DECK/PORCHES @ :20 ' „/ • l i wA' • / • TOTAL.. G. C> Iv"' v • . . • ) a • • . - . . . .. . . .. . . . . .. • . . _ . 457 p,71 .. - )4 ce -. �I . . ... . . . .• • - • . ..e. • . . .. . . . . . . . .. . . ;(7 . . ... . • • . • . . . . . . . . . • . . . . • ..• • • • 1 t � .• • - . . . .... • • . . • . • 5 $1• .. . . . . . . • . . . . . ______ .._ _ . . ... _________.._ ____._ . . SECTION 8 - CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: v► \ Not Applicable ❑ Name of License Holder :'��1 `� �v \ C y ts I ed, LicNur 1 \ � .�� \\Nottk o �O Jo r (A0 (9. Addr- ' Expiration Date �� ! - - o - 7 o Signature Telephone ,9:, isferleii l8Ne nirtV `hfiti1tC i r FP ° ! , ., .,_ "• . , Not Applicable IN-- Company Name Registration Number Address Expiration Date Telephone SECTION 10- WORKERS' COMPENSAT INSURANCE AFFIDAVIT ‘M G. ' c, 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes ❑ No ❑ tM.% -\ V v G. c & ( ' . (c k1 Sc 1a The current exemption for "homeowners" was extended to include Owner - occupied Dwellinss of one (1) or two(2) families and to allow such homeowner to engage an individual for hire who does not possess a license, provided that the owner acts as supervisor. CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person (s) who own a parcel of land on which he /she resides or intends to reside, on which there is, or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/ or farm structures. A person who constructs more than one home in a two -vear period shall not be considered a homeowner. Such "homeowner" shall submit to the Building Official, on a form acceptable to the Building Official, that he /she shall be responsible for all such work performed under the buildin¢ permit. As acting Construction Supervisor your presence on the job site will be required from time to time, during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152 (Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death) of the Massachusetts General Laws Annotated, you may be liable for person(s) you hire to perform work for you under this permit. The undersigned "homeowner" certifies and assumes responsibility for compliance with the State Building Code, City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature . SECTION 5- DESCRIPTION OF-- :PROPOSED IJV ,p (Oh cl 061(catj ) r F .. New House Addition ❑ Replacement Windows Alteration(s) ❑ Roofing in Or Doors C] Accessory Bldg. El Demolition ❑ New Signs Cl] Decks [Q Siding [DJ Other [D] Brief Descri ion of Proposed '�� —r Work: 4l n f'C1 -,es,) c. 1 4 P yiC /ri Alteration of existing bedroom Yes L Adding new bedroom Yes L— No Attached Narrative Renovating unfinished basement Yes ✓No Plans Attached Roll - Sheet l a Vifi ,. f aWis ', a, al:',, .tl d ° ® r i kk if : :' i. ,:.!: .11 a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: a Number of Bathrooms c. Is there a garage attached? ,\ta_ ®® r� d. Proposed Square footage of new construction. ' y U 0 F1 Dimensions ei� X oG e. Number of stories? f. Method of heating? 4. 12: 0 AE_ Fireplaces or Woodstoves I, C) Number of b each 0 g. Energy Conservation Compliance. /CS S Masscheck Energy Compliance form attached? V yS / i • h. Type of construction (tJo� C1'm � � � I. Is construction within 100 ft. of wetlands? Yes V No. Is construction within 100 yr. floodplain Yes l/No j. Depth of basement or cellar floor below finished grade 5' k. Will building conform to the Building ar:iymg regulations? Yes No .. I. Septic Tank City Sewer Private well City water Supply V SECTION 7a - OWNER AUTHORIZA £ TO B E C Wei N OWNERS AGENT OR.CONTRMCTOR APPLIES R � FO igg14,9 ?AF I IT a ,,, 1, 1 q vhe. Vc \ \ •{� 01;, rta� �' ` 1h ..vw f K lice, p�S _ , as Owner of the subject property J hereb authorize _& 'r .Q A \ al to a o m ,." - f, in all matters relative to work authorized by this building er it application. S nature . •caner imimmumummuili Da LacAjcEy1C1. - , as Owner /Authorized Agent hereby declare that the stateme p■-.00.1 nd information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalt' s of perjury. is s c_V\�..c 9J3 \ IS- Print Name / / • ...e.! ' .1'1111.441101...- 5 Cot g■ Signature of Owner /Agent Date - Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by *y Building Department Lot Size...._... 1 1...t,." !....� Frontage.... �.. ..__. _ ,.,_.__....^.. Setbacks Front Side L: 1 R I , L R:� „1 � ..._ ..... Rear.,..,, ...µ., 4 [t.! Building Height Bldg. Square Footage , M1 „ � F 1% [. 17 i Open Space Footage ( 1 (Lot area minus bldg & paved l r' .__„_._- parking) # of Parking Spaces �- C- .H- i Fill: (volume & Location) A. Has a Special Permit /Variance /Finding ever been issued for /on the site? NO 0 DON'T KNOW 0 YES e IF YES, date issued (2Qci- "j IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DONT KNOW 0 YES ef IF YES: enter Book (p (p Page 3 1 and /or Document # p Go 26 B. Does the site contain a brook, body of water or wetlands? NO ej DON'T KNOW 0 YES Q IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained ® , Date Issued: C. Do any signs exist on the property? YES 0 NO Ey IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property ? YES 0 NO IF YES, describe size, type and location: E. Will the construction activity disturb (clearing, grading, excav tion, or filling) over 1 acre or is it part of a common plan that will disturb over 1 acre? YES ( NO IF YES, then a Northampton Storm Water Management Permit from the DPW is required. REcEO � City of Northampton . - r _ '‘'.f r »; �� - Building Department ����fP��i���e� `s. � ���S�3 � ,w � "�st� kr�S��'���r. 3 2Z 212 Main Street a'k )g i :4 -iir -1 gill 2F .' � Room 100 r ?- ( ,) , it , 44 p'` i ll rli ' gyp. of BuiLDV "G wsPOC "s N rthampton, MA 01060 �,,, i 1 � � $ I 1 i ( -,1 � x x= NORTHAM °N "� one 413 - 587 -1240 Fax 413- 587 -1272 ` )11, • ? 1` 1. iP�,' . ' y APPLICATION TO CONSTRUCT, ALTER, REPAIR, RENOVATE OR DEMOLISFI A ONE OR TWO FAMILY DWELLING • SECTION 1 - SITE INFORMATION , 1.1 Pro ert Address: > 1r�i 3 6 -'41.- 1 C 18-- A i 1 _.,:.: iai.;a '' i s v °. S c `� =' Y f ",;;?, kggf 3 i SECTION 2 - PROPERTY OWNERSHIP /AUTHORIZED AG , 4. o r b 2.1 Owner of Record: r (o ,t .. v , 4 ' k�� nrvl�v�l t) �'o�c ((0i0 L i' eid.teI t tIN Ot�I;L P mt �'I ' Mailing I , is L � (�u` 11 � `` (�C Teleph Current ne Address: ��b4 Name (P Signa ure 2.2 Authorized Agent: k ci( rEY\c.F 1 ).L )1 14- IlErt'QF /L j 1 • JI'r,vfl (Print Current Mailing Address: . X1 — 3C o .'7°'8 Signature Telephone - SECTION 3 - ESTIMATED CONSTRUCTION COSTS Item Estimated Cost (Dollars) to be .)_ , Official:` Use 'Only' completed by permit applicant 1. Building (op dO�C s(a)`Bulldirrg Permit Fee i 2. Electrical fi Estimated Tots #I Cast of / 0 1 00a Construction fiorp:(6) 3. Plumbing 18 o a© ©0 F3uliding Permit Fee , 1 9 4. Mechanical (HVAC) / ,5-e 6° V 5. Fire Protection ( � 6. Total = (1 + 2 + 3 + 4 + 5) •g5 Check N umber 4 '7 �� o This': Section Fc r C?tficlal Use O nly, Iss Iss Building Permit Number: ed Signature: Building Commissioner /Inspector of = Buildings = - Dat File # BP- 2013 -0381 b p A v t. J p t i-16 a5 J u M APPLICANT /CONTACT PERSON LAWRENCE SAWULA a, f c ADDRESS/PHONE 73 PLAIN RD HATFIELD () 247 -5442 0 ° PROPERTY LOCATION 3 GARFIELD AVE 0 1 MAP 17D PARCEL 080 001 ZONE URB(100)/ r THIS SECTION FOR OFFICIAL USE ONLY: " 1 .f c g / C , � j t co PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid j 1 Buildin° Permit Filled out , �r� . , V • Fee Paid l� — • — 'll I' Typeof Construction: CONSTRUCT 2 STORY SFH W/PORCHES New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/ Statement or License 064587 3 sets of Plans / Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESENTED: i Approved _ Additional permits required (see below) i o PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND /OR Special Permit With Site Plan t ._ r 5 , 13 • �l 9 Major Project: Site Plan AND /OR Special Permit With Site Plan �� ZONING BOARD PERMIT REQUIRED UNDER: § i 1 Finding Special Permit Variance* Received & Recorded at Registry of Deeds Proof Enclosed o Other Permits Required: � Curb Cut from DPW Water Availability Sewer Availability 1 {a) 1 -*lilt t i . Septic Approval Board of Health Well Water Potability Board of Health --f'1 /W1 Permit from Conservation Commission Permit from CB Architecture Committee C .C`c , n Permit from Elm Street Commission _ Permit DPW Storm Water Management 5'"(! emolitio Delay Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning & Development for more information. 3 GARFIELD AVE BP- 2013 -0381 GIS #: COMMONWEALTH OF MASSACHUSETTS Map:Block: 17D - 080 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: New Single Family House BUILDING PERMIT Permit # BP- 2013 -0381 Project # JS- 2013 - 000616 Est. Cost: $95000.00 Fee: $616.40 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: LAWRENCE SAWULA 064587 Lot Size(sq. ft): 11064.24 Owner: PIONEER VALLEY HABITAT FOR HUMANITY INC Zoning: URB(100)/ Applicant: LAWRENCE SAWULA AT: 3 GARFIELD AVE Applicant Address: Phone: Insurance: 73 PLAIN RD 0 247 -5442 0 HATFIELDMA01038 ISSUED ON:10/22/2012 0:00:00 TO PERFORM THE FOLLOWING WORK: CONSTRUCT 2 STORY SFH W /PORCHES POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace /Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 10/22/2012 0:00:00 $616.40 212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272 Louis Hasbrouck — Building Commissioner